Pentair Two Speed Pool And Spa Pump Energy Master Users Manual

Hydropump to the manual 669c8dcf-5b14-c3d4-d185-84123663a5eb

2015-02-06

: Pentair Pentair-Two-Speed-Pool-And-Spa-Pump-Energy-Master-Users-Manual-518010 pentair-two-speed-pool-and-spa-pump-energy-master-users-manual-518010 pentair pdf

Open the PDF directly: View PDF PDF.
Page Count: 4

DownloadPentair Pentair-Two-Speed-Pool-And-Spa-Pump-Energy-Master-Users-Manual-  Pentair-two-speed-pool-and-spa-pump-energy-master-users-manual
Open PDF In BrowserView PDF
POSSIBLE CAUSES & SOLUTIONS

TROUBLE GUIDE
THE FOLLOWING ARE SOME COMMON CAUSES OF PROBLEMS THAT MAY ARISE:
PROBLEMS

A. PUMP WILL
NOT PRIME:

B. LOW FLOW

1. If filter gauge reads high.
a. Filter is dirty.
b. Clogged return lines.
2. If filter pressure gauge reads low.
a. Pump or skimmer strainer basket is clogged.
b. Skimmer or main drain valve is closed.
c. Air leak in suction line.
d. Impeller setting is incorrect.
e. Debris on impeller vanes.

Make sure pool water is midway of skimmer opening.
Make sure strainer basket is not clogged.
Make sure strainer basket is positioned properly!
Tighten lid down snugly.
Make sure strainer pot is full of water.
TIghten all fittings and seal all joints on suction side.
Clean skimmer and pump strainer baskets.
Remove pump lid and check for clogging.
Open all valves in return and suction lines.
Remove and replace pump seal if needed.
Check voltage at pump to be sure it is same as motor specs.

C. MOTOR
RUNS HOT

1. Motors will run hot to the touch, however, they are designed this way. Thermal
overload protector will function to turn the motor off if there is an overload problem.
2. Factors which will increase operating temperature:
a. Installed in direct sun.
b. Poor ventilation.
c. Low voltage.
d. Wiring is incorrect size for load.

1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.

D. MOTOR WILL
NOT TURN

Printed in the U.S.A.

This warranty does not cover failure in service due to fire, wreckage, freezing, willful abuse, improper repackaging
or damage incurred in shipping nor does it extend to consequential damages.

All adjustments are to be based on list prices in effect at the time of adjustment. PENTAIR POOL
PRODUCTS, INC. will not be liable for the cost of labor or removing or replacing parts. Purchase
agrees to prepay all shipping charges to and from PENTAIR POOL PRODUCTS, INC. 1620 Hawkins
Ave., Sanford, NC 27330 or 10951 West Los Angeles Ave., Moorpark, CA 93021, whichever is closer or more convenient.

PENTAIR POOL PRODUCTS, INC. pumps are warranted to be free from defects in material and
workmanship. Should any of the operating parts become defective within one year from date of purchase, they will be replaced or repaired if defect is proved to be the responsibility of PENTAIR POOL
PRODUCTS, INC.

PUMPS

P WARRANTY P

LIMITED

SAVE THESE INSTRUCTIONS.

1. Check that all power switches are on, fuse not blown, and circuit breaker
is not tripped.
2. Timer improperly set.
3. Impeller is against volute face.

35-7000
Rev. B 5/2005

®

™

HYDROPUMP
AND

®

ENERGY MASTER
HYDROPUMP

TWO SPEED POOL AND SPA PUMP

INSTALLATION, OPERATION
& SERVICE MANUAL

TABLE OF A.W.G. WIRE SIZE
FOR
SINGLE-PHASE POOL PUMP MOTORS
WIRE LENGTH
VOLTS
14

230

100 FEET

14

115

VOLTS
14

230

50 FEET

14
14

14

115

12
14

12
10
12

14

14
14
10

14

14
-

8

12
12
12

14

1
10
12

3/4
1 1/2
-

10

The strainer basket in pump should be inspected
and cleaned twice each week. The strainer basket is
easy to clean. Loosen the knobs and remove the
clear lid. Remove the basket and clean. Inspect the
Lid “O”-Ring; if damaged, replace. Install the Clear
Lid, tightening knobs by hand only. The pump seal
requires no lubrication. Refer to motor service center
for motors.

MAINTENANCE:

An alternate is to remove the pump and motor
from plumbing and store them indoors in a warm, dry
location.

In areas subject to freezing winter temperatures,
protect pump by removing both drain plugs, one from
the pump volute and one from the pot. Do Not
Replace Plugs, store them in strainer basket for the
winter.

WINTERIZING:

After the pump has been filled with water, and the
motor started, allow a few moments for the pump to
start pumping water. If flow does not start within four
minutes, stop motor and refer to (THE TROUBLE
GUIDE). Be sure all suction and discharge valves are
open when the pump is running. Operating the pump
with a closed valve in the system can cause pump
damage.

OPERATION:

Fill the pump pot with water before starting the
pump. This may be done by removing clear lid.
Pumps are self priming providing the pump pot is
filled with water. Should you lose this liquid from the
pot accidentally or by draining purposely, it will be
necessary to refill it with liquid before starting. High
Suction Lifts, require additional time for priming.

PRIMING:

WARNING - To reduce the risk of injury, do not
permit children to use this product unless they are
closely supervised at all times.

12

3

2

1/2

1/3

H.P.

INSTRUCTIONS
READ AND FOLLOW ALL INSTRUCTIONS
GENERAL:
Our shipping container has been specifically
designed to prevent transit damage. However, any
indications of damage should be carefully noted on
the delivery ticket and a claim filed promptly with the
carrier.
LOCATION:
Locate the pump as close as possible to the pool.
Provide the necessary space around the pump for
future inspection and servicing of the unit. If possible,
allow several inches of clearance below the motor to
floor to allow easy access to mounting screw. Locate
away from pool chemicals to prevent spilling on or
near motor.
INSTALLATION:
The pump suction line should not be smaller than
the pipe size on the inlet of the pump.
Your pump is made of the finest engineering
materials available today. A few simple precautions
taken during the initial installation, will insure many
long years of trouble-free operation.
The threads of pipe fittings screwed into pump
must be sealed with: pipe sealant, Teflon® Tape,
R.T.V. or other sealing materials approved for pipe
threads.
Tighten the pump fitting only as much as is
required to insure a tight connection. DO NOT OVER
TIGHTEN.
The piping should be supported independently
and not supported by the pump.
The pump motor must be wired for the proper
voltage, and rotation, in accordance with the wiring
diagram supplied with the motor. All wiring should be
done by a licensed electrician in accordance with
local codes, be certain that the motor frame is
grounded. Use lug on top of motor frame to bond
together motor and all metallic parts of pool, spa or
hot tub structure and to all electrical equipment,
metal conduit, and metal piping within 5 feet of the
inside walls of a swimming pool, spa or hot tub, when
the motor is installed within 5 feet of the inside walls
of the swimming pool, spa or hot tub structure with a
solid copper conductor not less than No. 8 A.W.G.
Motor name plate has voltage, phase, ampere
draw and other motor information. Terminal cover
plate or name plate has wiring connection information.
The wiring to motor should be kept as short as
possible and large enough to carry the necessary
current for required length without excessive voltage
drop. The following table should be followed to be
sure that the proper wire size is selected. Use as a
guide only.

2

WARNING: NEVER WORK ON PUMP WHILE IT IS RUNNING OR POWER IS STILL CONNECTED.

HOW TO ORDER PARTS

WHEN ORDERING PARTS, GIVE

--------------------

TO YOUR LOCAL DEALER

H.P., PUMP SERIAL NO., MODEL NO. & ITEM NO.

Qty.

1
1
2
4
8
1
1
1
1
1
1
1
2
1
1
2
1
1
1
1
1
1
1
1
1
1
2
1
1
2
1

35-3450
Motor Support (for 5 1/2 Dia. Motor)
15-4909
Motor Outrigger
35-4256
Set Screw 1/4” x 20 x 3/8” S.S.
35-4290
Cap Screw 3/8 - 16 x 1” S.S.
35-4265
Hex Washer Head Screw 5/16” - 18
35-4001
3/4 Mechanical Seal
35-2670
Basket w/Handle - Plastic 700
35-2656
Basket w/Handle - Plastic 590
35-2600
Lid O-Ring 700
35-2602
Lid O-Ring 590
35-3525
Clear Lid - 700 Plastic
35-3625
Clear Lid - 590 Plastic
35-4280
Knob - Pot Plastic
35-4127
Strainer Pot 700 (Plastic)
35-4125
Strainer Pot 590 (Plastic)
154699
Plug-Wing .25” Drain Lgr
19-2323
O-Ring (Pot to Volute)
35-3912
Volute - Plastic
35-2626
O-Ring Volute to Bracket
35-3220
Impeller RPF 3HP
35-3050
Impeller RPF 2HP, 21/2HP
35-3049
Impeller RPF 1 1/2HP, RPA 2HP
35-3013
Impeller RPF 1HP, 1 1/2HP
35-3044
Impeller RFP 3/4HP, RPA 1HP
35-3043
Impeller RFP 1/2HP, RPA 3/4HP
35-3041
Impeller, RPA 1/2 HP
15-4445
Hex Nut 3/8 - 16 Cad. Pltd.
35-4894
Pump Tri Pod Base Plastic
35-3775
Seal Bracket - Plastic
35-4294
Screw, Cap 3/8 - 16 x 1 1/4” Cad. Pltd.
35-3750
Shaft Extension - Bronze
Motor
Part No.
NAME OR DESCRIPTION
LIST OF MATERIAL OR PARTS LIST

ARE LOCATED ON PUMP

H.P., PUMP SERIAL NO. & MODEL NO.

22
21
20
19
18
17
16
16
15
15
14
14
13
12
12
11
10
9
8
7
7
7
7
7
7
7
6
5
4
3
2
1
Item

7

SPECIAL INSTRUCTION FOR TWO
SPEED ENERGY MASTER HYDROPUMP:

*These models have skip-a-day wheel. Remove skip
screws if not needed.

TIMER INSTALLATION FOR HI-LO SWITCHING
OF 2 SPEED HYDROPUMP®

Voltage
115
230

Timer Model
T175*
T176*

CAUTION: Manual switch on motor side box must be
disconnected when HYDROPUMP® is being controlled by the timer or the motor will be damaged.

NOTE: When time switch is ON - pump is on HI.
When time switch is OFF - pump is on LO.

2) Connect the timer to the motor following Diagram
3. All electrical connections to the motor should
be made in the side box.

Hydropump H.P.
3/4
1, 1 1/2, 2

1) Check to see that timer voltage is the same as
that of the HYDROPUMP® motor. The following
intermatic timers should be used.

An intermatic timer with single pole, double throw
switch may be used to automatically switch the
HYDROPUMP® between the high and low speed
modes at present intervals.

The performance of this pump will be the same at
high speed as the same model single speed pump,
both hydraulically and prime wise. At low speed the
pump will produce one half the flow and the pressure
will drop GREATLY which is due to much lower system friction. These lower friction losses result in
GREAT energy savings. On low speed the electrical
energy savings are 60%.
Turn motor to high speed for vacuuming the pool,
reading the pressure gauge to determine if cleaning
or back washing of filter is required, for fast clean-up
of pool water, and for priming the system to rid it of all
air. Turn motor to low speed for quiet operation and
electrical cost savings. Since the pump should be
operated mostly at low speed for cost savings, minor
adjustments may be required in the automatic chlorine dispenser, the skimmers and the heater due to
the lower flow. (See the equipment manufacturers
operation manuals).
All electrical work MUST be done by a licensed
electrician. Before working on motors be certain that
the electrical power is OFF at the main junction
box. TWO SPEED pumps have SINGLE VOLTAGE
motors which cannot be changed. See the motor
nameplate for the motor being installed. ALL electrical connections should be made in the SIDE BOX
which also includes a prewired HI-LO switch. See
Diagram 1.

If an automatic timer is installed to change
speeds, the wiring connected to the switch should be
removed and the BLACK wire discarded. See
Diagram 2. The timer should then be installed and
connected to the motor as follows:

4

TIMER INSTALLATION FOR PROGRAMMED
ON-OFF, HI-LO SWITCHING OF 2 SPEED
HYDROPUMP®
Automatic on-off and hi speed-lo speed control of
the ENERGYMASTER 2 speed pump can be
obtained by properly installing two appropriate
timers. One timer must have a single-pole, double
throw switch and the other must have a single-pole,
single throw switch. Both timers and the HYDROPUMP® motor must be designed to operate on the
same voltage.
Only Intermatic timers are discussed below, but
other types may be used if desired. The following
timers are recommended for this installation:

OPERATING INSTRUCTIONS

1) Set both clock dials to the exact time of day.

2) Locate the trippers on the clock dial of timer No.
2 to switch the HYDRO-PUMP® on and off at the
desired times.

3) Locate the trippers on the clock dial of timer No.
1 to switch the HYDRO-PUMP® between hi and
lo speed at the desired time. The timers should
always be programmed so that the HYDROPUMP® will always operate for 10 minutes minimum at hi speed when it is switched on. This
allows priming of the pump and evacuation of air
from the piping system.

4) The pump may be manually switched between hi
and lo speed by flipping the manual lever of timer
No. 1, and may be switched on and off by flipping
the manual lever of timer No. 2.

CAUTION: Always turn power off at main panel
before servicing switches or pumps.

Intermatic
Timer Model No.
S.P.D.T. S.P.S.T.
T175* T101
T176* T102
•These models have skip-a-day wheel. Remove skip
screws if not needed.

CAUTION: Be certain the wiring CANNOT allow both
the HI and LO speed motor windings to be energized
at the same time.

Voltage
115
230

1) Mount the timers side by side, between the power
supply and the HYDRO-PUMP® an Intermatic 2in-1 raintight case is ideal for this installation.

Hydropump
H.P.
3/4
1, 1 1/2, 2

2) Timer No. 1 will be used to control the hi speedlo speed switching of the motor.
3) Timer No. 2 will be used to automatically switch
the HYDRO-PUMP® on and off.
The clocks of both timers must run continuously
for the proper operation of the switching circuits.
Therefore it is necessary to make a connection
between line 1 and the clock input of timer No. 1. (See
Diagram 4.)

NOTE: When time switch 1 is ON - pump is on HI.
When time switch 1 is OFF - pump is on LO.
All wiring connections should be made with 12
A.W.G. or larger wire size. All wiring connections to
the HYDRO-PUMP® should be made inside the
motor side box. The 2 speed motor is designed to
operate on the voltage stamped on the nameplate
only. Wiring with a different line voltage will damage
the motor.

Do not install within an outer enclosure or
beneath the skirt of a hot tub or spa unless so
marked.

CAUTION: This pump is for use with permanently
installed pools and may also be used with hot tubs
and spas if so marked. Do not use with storable
pools. A permanently installed pool is constructed in
or on the ground or in a building such that it cannot
be readily disassembled for storage. A storable pool
is constructed so that it may be readily disassembled
for storage and reassembled to its original integrity
and has a maximum dimension of 18 feet and a maximum wall height of 42 inches.

5

6

Start the pump and check the amperage
draw. If the amperage exceeds the nameplate
rating or if the pump performs poorly the adjustment needs to be redone.

screwdriver handle away from the motor, this
will pull the impeller away from the volute. You
should move the shaft extension about 1/32”
and holding the screwdriver at this position firmly tighten the shaft extension set screws.

IMPELLER CLEARANCE ADJUSTMENT
The Hydropump has an open face impeller
which was precisely set at the factory. Under
normal operating conditions it is not necessary
to make further adjustment, however, if the
pump draws excessive current a slight adjustment may be required.
Loose the shaft extension set screws and
this will allow the mechanical seal spring to
force the impeller face to touch the volute. Place
a screwdriver between the motor bracket and
the shaft extension as depicted below. Move the

3



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : No
Page Count                      : 4
X Press Private                 : %%DocumentProcessColors: Black.%%EndComments
Producer                        : QuarkXPress(tm) 6.5
Create Date                     : 2005:05:20 09:48:47
Creator                         : QuarkXPress(tm) 6.5
EXIF Metadata provided by EXIF.tools

Navigation menu