Perlick Utility Coolers Us10Kp Users Manual

US4KP to the manual 7f0e3184-5a77-423b-8572-0d85211e4d7a

2015-02-06

: Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-518198 perlick-utility-coolers-us10kp-users-manual-518198 perlick pdf

Open the PDF directly: View PDF PDF.
Page Count: 12

MODEL NOS.
US4KP
US10KP
INSTALLATION AND OPERATION INSTRUCTIONS
UTILITY COOLERS
Table of Contents
Cabinet Specifications ......................................... 2
Preparing for Assembly
Tools Required .................................................... 3
Pre-Assembly ....................................................... 3
Placing the Utility Cooler ..................................... 3
Cam Lock Fastening Method ............................. 3
Assembling the Cooler
Preparing the Floor .............................................. 4
Assembly .............................................................. 4
Assembly Order-Four Keg Cooler ........................ 5
Assembly Order-Ten Keg Cooler ......................... 6
General Information
Electrical Requirements ....................................... 7
Starting the Cooler ............................................... 7
Temperature Control ............................................ 7
Ventilation Requirements ..................................... 7
Cleaning the Condensing Unit ............................. 7
Warranty Information ........................................... 7
Replacement Parts ............................................. 8
Wiring Diagrams
Four Keg Self-contained ...................................... 9
Ten Keg Self-contained ...................................... 10
8300 West Good Hope Road Milwaukee, WI 53223 Phone 414-353-7060 Fax 414-353-7069
Toll Free 800-558-5592 E-Mail: Perlick@Perlick.com www.Perlick.com
IMPORTANT INFORMATION
This manual has been prepared to assist you
in the installation of your Utility Cooler and to
acquaint you with its operation and maintenance.
We dedicate considerable time to ensure that our
products provide the highest level of customer
satisfaction. If service is required, your dealer
can provide you with a list of qualified service
agents. For your own protection, never return
merchandise for credit without our approval.
We thank you for selecting a Perlick product and
assure you of our continuing interest in your
satisfaction
IMPORTANT WARRANTY INFORMATION
To register your product, visit our web site at
(www.perlick.com). Click on “Commercial”, then
“Service”. You will see the link to “Warranty
Registration Form”. You must complete and submit
this form or the installation date will revert back to
the ship Date.
Form No. Z2026
Rev 01.28.09
2
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Installation and Operating Instructions
Sizes and Specifications, Utility Coolers - Self Contained
Form No. Z2026
Rev 01.28.09
MODEL NOS. US4KP US10KP
KEG CAPACITY 4 10
DIMENSIONS
EXTERIOR
(mm)
Length 47" (1194) 93" (2362)
Depth 47" (1194) 47" (1194)
Height 77" (1956) 79" (2007)
CONDENSING UNIT 1/31/2
FULL LOAD AMPS 8.5 10.2
MAX. FUSE 15 15
SHIPPING WEIGHT lbs. (kg) 700 (318) 1150 (522)
EXTERIOR Floor: Stucco galvanized steel. Roof, Walls & Doors: Stucco galvanized steel painted grey.
INTERIOR Floor: 16 gauge slip resistant stainless steell. Roof, Walls & Doors: 26 gauge stucco
galvanized steel.
ELECTRICAL 115 V, 60 Hz. 1ph AC. Junction box provided.
PLUMBING Evaporator condensate drains through access hole in wall. 20" x 1/2" I.D. drain line provided.
REFRIGERATION R134a refrigerant.
INSULATION 4" UL Class 1 urethane foam. Flame Spreading Rate: 25 or less.
Smoke Develop Rating: 450 or less.
DOORS Flush-mounted with cam-lift chrome hinges, automatic door closer, magnetic gaskets, chrome pull handle.
Standard right hinged. Door size: 30" W x 55" H.
FEATURES Light “ON” indicator in door. Light switch and fixture installed on evaporator. Thermometer furnished loose.
OPTIONAL ACCESSORIES • Foor rack • Keg shelf kit
14
14
47
4”
4”
4”
4”
4”
4”
4”
4421”
23 1/2
14
15
14
79
67
32 3/4
12
30
7”
9” 8
1”
REF
93
11
4”
7”
67
7717”
51 1/4 51 1/4
47
LIGHT BULB
W/GUARD
THERMOSTAT
REFRIGERATION
SLEEVE
REFRIGERATION
SLEEVE
TOP
VIEW
TOP
VIEW
FRONT
VIEW FRONT
VIEW
END
VIEW
END
VIEW
39
INSIDE
85INSIDE
39
INSIDE
39
INSIDE
28
INSIDE
DOOR
OPENING
28
INSIDE
DOOR
OPENING
LIGHT BULB
W/GUARD
4 KEG COOLER 10 KEG COOLER
11
23 1/2
33 1/2
32 3/4
24 1/2
9 1/2” 9 1/2”
C
L
C
L
C
L
JUNCTION
BOX
JUNCTION
BOX
C
L
4”
Tools Required
Tape Measure.
Chalk Line.
Caulking Gun.
Caulk (provided).
Clam Lock Wrench (provided).
Level.
Screw Driver.
Shims.
Pre-Assembly
Some panels have been protected with a strip-
pable film to prevent surface damage. Remove this
film before assembly. It is very difficult to remove it
from the panel edges after panels have been joined
together. Note: Do not store panels with protective
film in sunlight or high temperature areas for an
extended period of time.
Placing the Utility Cooler
This utility cooler should not be installed tight
against any building or adjacent cooler wall. A
minimum of two inches must be provided for air
circulation. Shims for leveling the floor must
also be incorporated into overall height and
clearance requirements.
Remote Units: A minimum four inch clearance is
required between the top of the utility cooler
and the ceiling of the building in which it is being
installed.
Self-contained Units: Sufficient clearance above the
cooler must be allowed for ceiling panel
and condensing unit installation. For ventilation
requirements, see page 7.
The Cam Lock Fastening Method
This utility cooler utilizes the cam-lock fastening
method. (See illustration on below.)
Insert the cam lock wrench into the lock before the
panels are pushed together. Turn the handle Cam
Hole counterclockwise as far as it will go to fully
cock the
cam. Note: The cam must be fully cocked to
assure proper locking. The panels should then be
pushed together tightly and locked by turning the
wrench clockwise.
Plugs are provided to insert in cam-lock holes after
final assembly.
3
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Form No. Z2026
Rev 01.28.09
Preparing the Cabinet for Use
CAM
CAM
HOLE
MODEL NOS. US4KP US4KP
KEG CAPACITY 4 10
DIMENSIONS
EXTERIOR
(mm)
Length 47" (1194) 93" (2362)
Depth 47" (1194) 47" (1194)
Height 77" (1956) 79" (2007)
CONDENSING UNIT 1/31/2
FULL LOAD AMPS 8.5 10.2
MAX. FUSE 15 15
SHIPPING WEIGHT lbs. (kg) 700 (318) 1150 (522)
EXTERIOR Floor: Stucco galvanized steel. Roof, Walls & Doors: Stucco galvanized steel painted grey.
INTERIOR Floor: 16 gauge slip resistant stainless steell. Roof, Walls & Doors: 26 gauge stucco
galvanized steel.
ELECTRICAL 115 V, 60 Hz. 1ph AC. Junction box provided.
PLUMBING Evaporator condensate drains through access hole in wall. 20" x 1/2" I.D. drain line provided.
REFRIGERATION R134a refrigerant.
INSULATION 4" UL Class 1 urethane foam. Flame Spreading Rate: 25 or less.
Smoke Develop Rating: 450 or less.
DOORS Flush-mounted with cam-lift chrome hinges, automatic door closer, magnetic gaskets, chrome pull handle. Standard right
hinged. Door size: 30" W x 55" H.
FEATURES Light “ON” indicator in door. Light switch and fixture installed on evaporator. Thermometer furnished loose.
OPTIONAL ACCESSORIES • Foor rack • Keg shelf kit
General Information
Preparing the Floor
Snap a chalk line on the building floor to establish
cooler location. Place floor panel(s) on the floor and
check for level. A level floor is essential to ensure
that vertical panels will be plumb. If shimming
is required to level the sections, the shims must
extend under the entire section, not just the edges.
Shims should be used at each end, at all wall
seams, and at each floor seam. They should not be
spaced further than 24 inches apart.
Assembly
1. Place (do not slide) all sections into position.
2. Each panel is numbered on the edge. For a four
keg cooler, follow the assembly order on page
5. For a ten keg cooler, the assembly order
appears on page 6.
Note: If ceiling height in building is restricted,
panel(s) can be carried through the door open-
ing and placed into position from inside the
cooler.
3. Install cap plugs in all cam-lock holes.
4. Seal cooler to the floor.
4
Form No. Z2026
Rev 01.28.09
FLOOR PANEL
SEAL COOLER TO FLOOR
AFTER UNIT IS LEVEL AND
ASSEMBLED
CEILING
KEEP GASKETS
OUT OF GROOVE
FLOOR
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
5Form No. Z2026
Rev 01.28.09
Four Keg Cooler
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Four Keg Cooler Assembly
Assemble panels as follows:
Section 1: .............. Floor
Section 2: .............. Left Wall
Section 3: .............. Left Back Wall
Section 4: .............. Right Back Wall
Section 6: .............. Front with Door
Section 5: .............. Right Wall
Section 7: .............. Ceiling
FRONT VIEW
FLOOR
3
PANEL NO.#’S
UNIT
COOLER
4
6
1
5
7
2
6
Form No. Z2026
Rev 01.28.09
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Ten Keg Cooler
Ten Keg Cooler Assembly
Assemble panels as follows:
Section 1 & 2: ........ Floor-Section
Section 3: .............. Left Wall
Section 4: .............. Left Back Wall
Section 5: .............. Right Back Wall
Section 3A: ............ Right Wall
Section 6: .............. Right Front Wall
Section 7: .............. Door Section
Section 8: .............. Left Front Panel
Section 9: .............. Celing Panel with
Evaporator Housiing
Section 10: ............ Celing Panel
FRONT VIEW
COOLER
UNIT
COOLER
PANEL NO.#’S
45
33A
921
6
8
10
10
7
9
7
Form No. Z2026
Rev 01.28.09
General Information
Electrical Requirements
The package unit must be installed so that the wir-
ing conforms to, and is in accordance with National
and Local Electrical Codes. (See Condensing Unit
Data Plate for Electrical Specifications.
CAUTION: Do not attempt to operate the condens-
ing unit on any other power source than that listed
on the unit data plate. See appropriate wiring dia-
gram on pages 9, 10 or 11.
Starting The Cooler
Allow the empty utility cooler to operate 24 hours
for a settling-out period before use.
Temperature Control
The temperature control is located on the evapo-
rator housing. It is factory adjusted to maintain a
temperature of approximately 34° F. cut out and
40° F. cut in. Cut out temperatures lower than 34°F.
are not advisable as excessive frost may accumu-
late on the evaporator.
If excessive frost does accumulate, the unit is
operating at too cold a temperature. To defrost the
evaporator, turn off the electrical power to the con-
densing unit or turn the control to a warmer posi-
tion to allow the fan motor to defrost it. The control
should then be reset to a temperature that will not
ice up the evaporator. A plastic drain hose should
be attached to the drain pan of the evaporator and
routed through the wall panel. A receptacle should
be provided for accumulated condensing water or
connect to a building drain facility.
Ventilation Requirements
Air-cooled units must be furnished with sufficent
ventilation to maintain their efficiency. The table
at right indicates the minimum room size/cubic
footage, only the space above the condensing
unit can be used. When the room size is below
minimum, some type of forced ventilation must
be provided.
There should be nothing on or around the machin-
ery compartment area which will restrict the flow of
room temperature air to the condenser or over the
compressor.
Compressor H.P.
Natural
Circulation Cu.
Ft. Room Volume
Needed
Forced Air
Circulation C.F.M.
Fresh Air Entering
Room
1/3 to 1/2 600 220
Cleaning the Condensing Unit
Inspect the machinery compartment every 60 days.
A heavy accumulation of dirt and/or grease on
the front of the condensing unit (radiator) must be
cleaned off with a stiff brush or vacuum cleaner. Be
careful not to bend the aluminum fins on the con-
densing unit.
Warranty
This Utility Cooler is fully warranted against defects
in both material and workmanship for a period
of one (1) year from date of sale. Defective parts
must be returned to Perlick freight prepaid. All
parts found to be defective upon inspection will be
replaced on a no-charge basis, F.O.B. our factory.
Perlick is not responsible for parts damaged by
alteration, unauthorized service, accident or abuse.
All costs incident to replacement, including labor,
refrigerant, and/or loss of sales are incidental to
this warranty and must be borne by the user.
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
8
Form No. Z2026
Rev 01.28.09
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Replacement Parts
How to Order Replacement Parts
Contact your local Perlick dealer to order
replacement parts.
Be prepared to provide the model and serial num-
ber of the cooler. The serial number is
printed on a label which is attached to the inside
wall, adjacent to the evaporator housing.
SELF-CONTAINED UTILITY COOLERS
FOUR KEG TEN KEG
Description Part Number Description Part Number
Compressor Only 57499 Compressor Only 57860
Condensing Unit Fan Motor 57513 Condensing Unit Fan Motor C15250A2
Condensing Unit Fan Blade C3150-3 Condensing Unit Fan Blade C15250A3
Evaporator Coil Assembly 57861 Evaporator Coil Assembly 57872
E xpansion Valve 57877 E xpansion Valve 57877
Temp. Control (two-wired) 57891 Temp. Control (two-wired) 57891
ALL MODEL UTILITY COOLERS
Description Part Number Description Part Number
Switch 57878 Evaporator Fan Guard 57875
Light Bulb C31358 Plug Button 57882
Bulb Guard C25969-1 Door Sill 57883
Thermometer 57879 Door Closure 57884
Hinged Door Assy. 57880 Light Indicator 57858
Gasket-Door Assy. 57881 Hinge 57885
Evaporator Fan Motor 57873 Handle 57886
Evaporator Fan Blade 57874 Door Wiper Gasket 57908
9
Form No. Z2026
Rev 01.28.09
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Wiring Diagram Four Keg Self-Contained Cooler
OVERLOAD
RELAY
FAN
GREEN
BROWN
WHITE
WHITE
WHITE
WHITE
WHITE
BROWN
BROWN
LIGHT
SWITCH
BLACK
BLACK
BLACK
EVAPORATOR
FAN MOTORS
(ELECTRONIC)
THERMOSTAT
(4 MIN. “ON” DELAY)
(ALTERNATE)
THERMOSTAT
(STANDARD)
BLACK
GREEN
GREEN
COMPRESSOR
TERMINALS
CAPACITOR
L1
12
C
RS
L2
10
Form No. Z2026
Rev 01.28.09
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
Wiring Diagram Ten Keg Self-Contained Cooler
OVERLOAD
RELAY
1
L
3
1
C
R
S
5
M
2
GREEN
BROWN
GREEN
WHITE
EVAPORATOR
FAN MOTORS
BLACK
WHITE
WHITE
BLACK
LIGHT
SWITCH
BLACK
WHITE
FAN
CONDENSER
COMPRESSOR
TERMINALS
BROWN
GREEN
WHITE
RED
YELLOW
BLUE
CAPACITOR
(ELECTRONIC)
THERMOSTAT
(4 MIN. “ON” DELAY)
(ALTERNATE)
THERMOSTAT
(STANDARD)
BLACK
BROWN
11
Form No. Z2026
Rev 01.28.09
Perlick is committed to continuous improvement. Therefore, we reserve the right to change specifications without prior notice.
8300 West Good Hope Road Milwaukee, WI 53223 Phone 414-353-7060 Fax 414-353-7069
Toll Free 800-558-5592 E-Mail: Perlick@Perlick.com www.Perlick.com
Form No. Z2026
Rev 01.28.09
Page 1 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 2 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 3 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 4 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 5 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 6 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 7 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 8 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 9 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 10 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 11 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual
Page 12 of 12 - Perlick Perlick-Utility-Coolers-Us10Kp-Users-Manual-  Perlick-utility-coolers-us10kp-users-manual

Navigation menu