Persona Medical OPA Hearing Aid User Manual

Persona Medical Hearing Aid

User manual

Identifying Your DeviceEarbud (waxbasket inside)Battery Door2nd MicrophoneMicrophoneReceiver Unit (RU)Welcome back to the world of sound!™A belief that in order to succeed, you must have a cer-tain passion and desire to give your every endeavor your very best.  For over 50 years, Persona Medical  forged this very commitment to excellence into every hearing instrument we design.  A rare combination of state of the art technology and custom craftsmanship brings you the best instruments available today.  Currently, our products are distributed all over the world. We thank you for allowing us to as-sist with your hearing needs.These instructions along with the guidance from your Hearing Healthcare Professional will help you attain the maximum benet from your hearing instrument(s). Open Fit Hearing Instruments®PRODUCTMANUALUG_OPA400_PM 10 © 17Persona Medical170 N. Cypress WayCasselberry, FL USA 32707www.PersonaMedical.comTel: (407) 339-2422Info@PersonaMedical.comPush Button (Memories)The serial number is on the bottom of the case while the model is on the battery door.  Features*•100% Digital•Push Button (Multi-memory)•Adaptive Noise Reduction•Directional Microphones•Adjustable Power On Delay•Low Battery Indicator•Memory Tone Indicator•Telecoil•Replaceable Snap-TipEarbuds•Adaptive FeedbackReduction•Adaptive SpeechEnhancement* Not all features may apply to your instrument.With the CE marking PersonaMedical declares that this hearing instrument is in compliance with the European Directive 93/42/EEC concerning medical devices, as well as Directive 99/5/EC (R&TTE) concerning radio and telecommunications terminal equipment. A copy of the Declaration of Conformity can be obtained from the below address:Persona Medical, 170 N. Cypress Way, Casselberry, FL 32707 USACopyright © 2018 Persona Medical • All rights reserved. No part of this publication may be reproduced without permission from Persona Medical.US Patents 7,139,404; 8,976,991 Other Patents Pending. LICENSING:FCC ID: 2AOWB-OPACONFORMANCE INFORMATION0120 EUROPEAN AUTHORIZED          REPRESENTATIVE:Wellkang Ltd, 29 Harley Street, LONDON W1G 9QREngland, United KingdomWellkang.ltd.ukEC REP
NOTE: Some irritation may occur due to becoming accustomed to wearing a new hearing instrument. If swelling or redness occurs, discontinue use and visit your Doctor.Inserting / Removing your DevicePowering your Device / Controls Maintenance for your DeviceOn - With your nger, gently open the door. Insert battery and close the door. Your instrument will take several sec-onds before it turns on.When placing the battery in your instrument, be sure to position  the positive (+) symbol face up into the battery door.O -  To turn your hearing instrument o, simply open  the battery door. Store in a safe dry place.Batteries - Uses a 312 battery Inserting  - Before insertion, make sure the battery door is closed properly. The procedure for inserting your instrument:1. To properly position your hearing instrument,hold the base of the Receiver Unit (RU) wire withthe thumb and index nger, allowing the earbudto be freely inserted into the ear canal.2. At this point, the instrument is inverted fromits nal position. Carefully insert the earbud intothe ear canal3. While holding the RU in place in the ear canalwith your thumb or index nger, carefully rotatethe hearing instrument over the top of your earwhile pressing it against the head.4. If correctly placed, the hearing instrument willbe virtually invisible to others. Make sure that the receiver unit is still properly positioned in your ear canal.2134It is recommended that you clean your hearing instrument daily. Inspect the wax basket and the microphone opening(s) to make sure they are clear of ear wax and debris.Daily, brush the white wax basket while holding instrument upside down (1), so debris will fall out of the earbud wax basket. Also, brush the microphone port (2). If the hearing instrument is weak or not working, you may need to replace the earbud.Before you store the instrument, wipe the instrument with a dry tissue (3). Do not use a wet wipe or alcohol because moisture may seep into the receiver opening. Removing and installing the earbudHold the RU wire (D) with one hand, and pull the white ear-bud in the opposite direction. Snap on a new earbud until you feel it click.  Earbuds are generally not cleanable.123DCAUTION: Batteries are dangerous if swallowed! Keep batteries out of the reach of children. Never put batteries in your mouth for any reason they are easily swallowed. In the event a battery has been swallowed, seek immediate medical attention. For more information call the National Battery Hotline at 202-625-3333. Earbuds / TipsA. RU with earbudB. RU with ZipTip -Keep the small vent hole (C)  to  the bottom  of  the  earfarther from the deviceA BCReplacing Earbuds / TipsFCC COMPLIANCEYour hearing system complies with Part 15 of the Federal Com-munication Commission(FCC) rules. Operation is subject to the following conditions:1. This device may not cause harmful interference.2. This device must accept any interference received, including interference that may cause undesired operation.Changes or modifications not expressly approved by the party responsible for compliance could void the user’s authority to operate the equipment.3. Changes or modifications not expressly authorized by Persona Medical could void the user's ability to operate this device.TECHNICAL INFORMATIONYour hearing system contains a radio transmitter using short range magnetic induction technology working at 10.597 MHz. The magnetic field strength of this transmitter is -16.8dBμA/m @ 2m. The emission power from this radio system is well below international emission limits for Human Exposure. The hear-ing system complies with international standards concerning Electromagnetic Compatibility. Check with your hearing care professional to determine if your hearing system contains a radio transmitter.SAFETY INFORMATIONWARNING: Although your hearing system has been designed to comply with the most stringent international electromagnetic compatibility standards, the possibility cannot beexcluded that it may cause interference with other equipment, such as medical devices. It is also possible that unforeseen in-terference may occur in the hearing aid due to electromagnetic radiation from other products such as alarm systems, room surveillance equipment, and mobile phones.Only for two instruments or the use of a remote control: In some countries restrictions for the usage of wireless equipment exist. Refer to local authorities for further information. Telephone -  Simply press the push button to the memory assigned for telephone use.  If you have two devices, the wireless functionality will automatically enable you to hear in both ears.Memories -    To change the memory, press the control switch on one device, and the wireless functionality will automatically make the same memory selection in the other device.

Navigation menu