Persona Medical OPA Hearing Aid User Manual

Persona Medical Hearing Aid

User manual

Download: Persona Medical OPA Hearing Aid User Manual
Mirror Download [FCC.gov]Persona Medical OPA Hearing Aid User Manual
Document ID3849149
Application IDFaplpDT92ry/ERJLy0uRMw==
Document DescriptionUser manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize30.49kB (381186 bits)
Date Submitted2018-05-14 00:00:00
Date Available2018-05-14 00:00:00
Creation Date2017-09-29 15:39:49
Producing SoftwareAdobe PDF Library 15.0
Document Lastmod2018-04-12 12:57:15
Document TitleUser manual
Document CreatorAdobe InDesign CC 2017 (Macintosh)

CONFORMANCE INFORMATION
EC
REP
EUROPEAN AUTHORIZED
REPRESENTATIVE:
Wellkang Ltd, 29 Harley Street,
LONDON W1G 9QR
England, United Kingdom
Wellkang.ltd.uk
0120
With the CE marking Persona
Medical declares that this hearing
instrument is in compliance with the European
Directive 93/42/EEC concerning medical devices, as
well as Directive 99/5/EC (R&TTE) concerning radio
and telecommunications terminal equipment. A copy
of the Declaration of Conformity can be obtained
from the below address:
™
Identifying Your Device
®
Welcome back to the world of sound!
A belief that in order to succeed, you must have a cer-
Receiver Unit (RU)
tain passion and desire to give your every endeavor
your very best. For over 50 years, Persona Medical
Microphone
PRODUCT
MANUAL
2nd Microphone
Push Button (Memories)
Earbud (waxbasket inside)
Battery Door
forged this very commitment to excellence into every
hearing instrument we design.
Open Fit Hearing Instruments
The serial number is on the bottom of the case while the
model is on the battery door.
Persona Medical, 170 N. Cypress Way, Casselberry,
FL 32707 USA
Copyright © 2018 Persona Medical • All rights
reserved. No part of this publication may be
reproduced without permission from Persona
Medical.
US Patents 7,139,404; 8,976,991 Other Patents
Pending.
LICENSING:
FCC ID: 2AOWB-OPA
A rare combination of state of the art technology and
Features*
• 100% Digital
• Push Button (Multi-memory)
• Adaptive Noise Reduction
• Directional Microphones
• Adjustable Power On Delay
• Low Battery Indicator
• Memory Tone Indicator
• Telecoil
• Replaceable Snap-Tip
Earbuds
• Adaptive Feedback
Reduction
• Adaptive Speech
Enhancement
Persona Medical
170 N. Cypress Way
Casselberry, FL USA 32707
www.PersonaMedical.com
Tel: (407) 339-2422
Info@PersonaMedical.com
* Not all features may apply to your instrument.
UG_OPA400_PM 10 © 17
custom craftsmanship brings you the best instruments
available today. Currently, our products are distributed
all over the world. We thank you for allowing us to assist with your hearing needs.
These instructions along with the guidance from your
Hearing Healthcare Professional will help you attain the
maximum benefit from your hearing instrument(s).
FCC COMPLIANCE
Your hearing system complies with Part 15 of the Federal Communication Commission
(FCC) rules. Operation is subject to the following conditions:
1. This device may not cause harmful interference.
2. This device must accept any interference received, including
interference that may cause undesired operation.
Changes or modifications not expressly approved by the party
responsible for compliance could void the user’s authority to
operate the equipment.
3. Changes or modifications not expressly authorized by
Persona Medical could void the user's ability to operate this
device.
TECHNICAL INFORMATION
Your hearing system contains a radio transmitter using short
range magnetic induction technology working at 10.597 MHz.
The magnetic field strength of this transmitter is -16.8dBμA/m
@ 2m. The emission power from this radio system is well below
international emission limits for Human Exposure. The hear-ing
system complies with international standards concerning
Electromagnetic Compatibility. Check with your hearing care
professional to determine if your hearing system contains a
radio transmitter.
SAFETY INFORMATION
WARNING: Although your hearing system has been designed
to comply with the most stringent international electromagnetic
compatibility standards, the possibility cannot be
excluded that it may cause interference with other equipment,
such as medical devices. It is also possible that unforeseen interference may occur in the hearing aid due to electromagnetic
radiation from other products such as alarm systems, room
surveillance equipment, and mobile phones.
Only for two instruments or the use of a remote control: In
some countries restrictions for the usage of wireless equipment
exist. Refer to local authorities for further information.
Powering your Device / Controls
Inserting / Removing your Device
Maintenance for your Device
Replacing Earbuds / Tips
Batteries - Uses a 312 battery
Inserting - Before insertion, make sure the battery door is
closed properly. The procedure for inserting your instrument:
It is recommended that you clean your hearing instrument daily.
Earbuds / Tips
On - With your finger, gently open the door. Insert battery
and close the door. Your instrument will take several seconds before it turns on.
Inspect the wax basket and the microphone opening(s) to make
When placing the battery in your instrument, be sure to
position the positive (+) symbol face up into the battery
door.
Off - To turn your hearing instrument off, simply open the
battery door. Store in a safe dry place.
Telephone - Simply press the push button to the memory
assigned for telephone use. If you have two devices, the
wireless functionality will automatically enable you to hear
in both ears.
Memories - To change the memory, press the control
sure they are clear of ear wax and debris.
the thumb and index finger, allowing the earbud
Daily, brush the white wax basket while holding instrument
hold the base of the Receiver Unit (RU) wire with
upside down (1), so debris will fall out of the earbud wax basket.
2. At this point, the instrument is inverted from
is weak or not working, you may need to replace the earbud.
the ear canal
Before you store the instrument, wipe the instrument with a dry
3. While holding the RU in place in the ear canal
may seep into the receiver opening.
its final position. Carefully insert the earbud into
while pressing it against the head.
4. If correctly placed, the hearing instrument will
Removing and installing the earbud
Hold the RU wire (D) with one hand, and pull the white earbud in the opposite direction. Snap on a new earbud until
you feel it click. Earbuds are generally not cleanable.
receiver unit is still properly positioned in your ear
canal.
NOTE: Some irritation may occur due to becoming
accustomed to wearing a new hearing instrument. If
swelling or redness occurs, discontinue use and visit your
Doctor.
farther from the device
tissue (3). Do not use a wet wipe or alcohol because moisture
be virtually invisible to others. Make sure that the
Keep the small vent hole (C) to the bottom of the ear
Also, brush the microphone port (2). If the hearing instrument
with your thumb or index finger, carefully rotate
A. RU with earbud
B. RU with ZipTip -
to be freely inserted into the ear canal.
the hearing instrument over the top of your ear
switch on one device, and the wireless functionality will
automatically make the same memory selection in the
other device.
CAUTION: Batteries are dangerous if swallowed! Keep
batteries out of the reach of children. Never put batteries
in your mouth for any reason they are easily swallowed. In
the event a battery has been swallowed, seek immediate
medical attention. For more information call the National
Battery Hotline at 202-625-3333.
1. To properly position your hearing instrument,

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.7
Linearized                      : Yes
Create Date                     : 2017:09:29 15:39:49-04:00
Creator                         : Adobe InDesign CC 2017 (Macintosh)
Modify Date                     : 2018:04:12 12:57:15-04:00
Has XFA                         : No
Language                        : en-US
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Instance ID                     : uuid:d8245ee4-30e2-4637-9b8b-993391ec81b3
Original Document ID            : adobe:docid:indd:4558c495-fa2e-11e0-8828-ddd7d19ab606
Document ID                     : xmp.id:4077fe61-ac76-4eb0-936f-5e2d2a3a90e1
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:1057b36d-1220-4fb1-8259-84223fcf4607
Derived From Document ID        : xmp.did:95a4a07e-7a44-4cb9-b561-ce14ac186726
Derived From Original Document ID: adobe:docid:indd:4558c495-fa2e-11e0-8828-ddd7d19ab606
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC 2017 (Macintosh)
History Changed                 : /
History When                    : 2017:09:29 15:39:49-04:00
Metadata Date                   : 2018:04:12 12:57:15-04:00
Creator Tool                    : Adobe InDesign CC 2017 (Macintosh)
Format                          : application/pdf
Producer                        : Adobe PDF Library 15.0
Trapped                         : False
Page Layout                     : OneColumn
Page Mode                       : FullScreen
Page Count                      : 2
EXIF Metadata provided by EXIF.tools
FCC ID Filing: 2AOWB-OPA

Navigation menu