Philio Technology PAD06 Smart Dimmer Socket User Manual

Philio Technology Corporation Smart Dimmer Socket

User manual

PAD06   Zigbee Smart Dimmer Socket                                              Warning:  Do not use Non-Dimmable LED lamps.PAD06 is an E27(EU)/ E26(US) Edison screw based lamp socket, based on Zigbee technology, which provides electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and support it in the lighting fixture. The use of socket allows lamps to be safely and conveniently replaced. You can On/Off the light by pressing the button briefly, or a long pressing to control the brightness of dimmable light bulb.Join/Leave Network* Join Network without user actionPower on the device, it will enter the find and join network mode.* Join network with user action 1. Making the zigbee network in the permitting joining mode.2. Pressed the button of PAD06 three times in two seconds.  the PAD06 willscan and try joining the network.* Reset to factory default / Leave network 1. Pressed the button three times in two seconds, and do not release the button in the 4th pressed without 5 seconds.2. The device will leave the network, and LED will turn on.User Interface* Button Function1. Relay ControlWhen pressed and released button, the PAD06 will control the relay in toggling way.For example, if you press the button then release and the relay is off, the device will turn the relay on.See the LED function for more information.1
2. Dimmer ControlWhen long pressing button, the PAD06 will control the brightness of dimmable  light bulb.3. Join networkWhen pressed and released button three in 2 seconds, the PAD06 will do finding and joining network.4. Reset to default / Leave networkPressed the button three times in two seconds, and do not release the button in the 4th pressed without 5 seconds, the PAD06 will do reset to default.* LED Function1. Relay StatusIf the relay is on, the device will turn the LED on.If the relay is off, the device will turn the LED off.2. Reset to default / Leave networkWhen PAD06 reset to default / leave network the relay will turn on.3. Try joining networkPower on the device, if PAD06 doesn't join network, the device will auto start the try joining network mode. The LED will light on one second.  Programming* Zigbee Cluster Library DescriptionThe PAD06 support Profile Home Automation v1.2 (profile is is 0x0104). The device is hosted in endpoint 1 (0x01).* Supported Clusters ListCluster ID Cluster Name0x0000 Basic0x0004 Group0x0005 Scenes0x0006 ON/OFF0x0008 Level Control* Basic Cluster (Cluster ID :0x0000)Attribute ID Attribute Name Attribute Type Default Value0x0500 Model identifier CHAR2
* Group Cluster (Cluster ID :0x0004)RequestgroupId : 0xABCD (by user)groupName : 0x00 (by user)* Scenes Cluster (Cluster ID :0x0005)RequestsceneId : 0x01 (by user)extensionFieldSets : cluster id, length, valuecluster id : scenes to do cluster id.length : value length.* ON/OFF Cluster (Cluster ID :0x0006)1. Read Relay StatusRequestAttrebute ID : 0x0000ResponseAttrebute Data : 0x00(OFF), 0x01(ON)2. Control RelayAttrebute Date : 0x00(OFF), 0x01(ON)* Level Control Cluster (Cluster ID :0x0008)1. Read Current LevelRequestAttrebute ID : 0x0000ResponseAttrebute Data : 0x00(1 byte for current level)2. Level Controlcommand id : 0x00level : 0x00 (by user)transition time : 0x0000 (by user)3. Level Control Move Modecommand id : 0x01movemode : 0x01 (turn on) , 0x00 (turn off)rate : 0x0A4. Level Control Stepcommand id : 0x02stepmode : 0x00 (turn on one step) , 0x01 (turn off one step)setpsize : 0x0A (by user)transition time : 0x0000 (by user)3
5. Level Control Stopcommand id : 0x036. Level Control With ON/OFFcommand id : 0x04level : 0x00 (by user)transition time : 0x0000 (by user)7. Level Control Move Mode With ON/OFFcommand id : 0x05movemode : 0x01 (turn on) , 0x00 (turn off)rate : 0x0A8. Level Control Step With ON/OFFcommand id : 0x06stepmode : 0x00 (turn on one step) , 0x01 (turn off one step)setpsize : 0x0A (by user)transition time : 0x0000 (by user)9. Level Control Stop With ON/OFFcommand id : 0x07Note: In level control cluster, all with on/off command can control PAD06  without relay on/off, but  the eithers command only control when relay on.Over The Air (OTA) Firmware UpdateThe device support the Zigbee firmware update via OTA.Before starting the procedure, please remove the front cover of thedevice. Otherwise the hardware check will be failed.Choosing a Suitable Location1. Do not locate the dimmer facing direct sunlight, humid or dusty place.2. The suitable ambient temperature for the Switch is 0°C~40°C.3. Do not locate the dimmer where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.4. After putting it into use, the body of dimmer will become a little bit hot of which phenomenon is normal.4
screw lamp holder Type:Since the socket type for each country in Europe varies, refer to the outline for each socket suited for each country as follows:EU TYPE: PAD06-1US TYPE: PAD06-2Note: Please make sure that the intensity of the screw lampholder of the electrical device must be Maximum Load (Ampere) and have same head as the enclosed screw lampholder before inserting to the socket. 5
Troubleshooting                 Symptom Cause of Failure RecommendationThe Switch not working and LED off1. The Switch is not plugged into the electrical outlet properly2. The Switch break down1. Check power connections2. Don’t open up the Switch and send it for repair.The Switch LED illuminating, but cannot control the ON/OFFSwitch of the load attached1.Check if the load plugged into the Switch has its own ON/OFF switch2. The switch is protected1. Set the ON/OFF switch of the load attached to ON2. Unprotected the switch or follow the instruction of protection.The Switch LED illuminating, but the Detector cannot controlthe Switch1. Not carry out association2. Same frequency interference1. Carry out association2. Wait for a while to re-trySpecificationOperating Voltage: 100V~240V / 50Hz~60HzMaximum Load (watts): 40W (Incandescent bulbs); ( PAD06-1; PAD06-2)Maximum Load (watts): 13W (Dimmable LED bulbs); ( PAD06-1; PAD06-2)Screw lamp holder Type: EU type: E27 to E14; PAD06-1 US type: E26 to E12; PAD06-2Operating Temperature: 0°C ~ 40°CFrequency Range: 2405MHz~2475MHz(EU)(US/Canada)(TW/JP)RF Radiated Power: +1dBm Transmission Range: Minimum 40 m in door 100m outdoor line of sightModulation Type:  O-QPSK - Offset - Quadrature Phase Shift Keying** Specifications are subject to change and improvement without notice.                    FCC ID : RHHPAD06Warning:  Do not use Non-Dimmable LED lamps.6
Warning:1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating.3. Do not use Non-Dimmable LED lamps.Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm tothe environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.Company of License Holder:Philio Technology CorporationAddress of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257, Taiwan(R.O.C) FCC Interference StatementThis equipment has been tested and found to comply with the limits for a Class B digital de-vice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference toradio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, whichcan be determined by turning the equipment off and on, the user is encouraged to try to cor-rect the interference by one of the following measures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.This transmitter must not be co-located or operating in conjunction with any other antenna ortransmitter.FCC RF Exposure Information (SAR)1. To comply with FCC RF exposure compliance requirements, a separation distance of at least20 cm must be maintained between the antenna of this device and all persons. 2. This Transmitter must not be co-located or operating in conjunction with any other antenna or transmitter.7