Philio Technology PAD06 Smart Dimmer Socket User Manual
Philio Technology Corporation Smart Dimmer Socket
User manual
PAD06 Join/Leave Network Zigbee Smart Dimmer Socket * Join Network without user action Power on the device, it will enter the find and join network mode. * Join network with user action 1. Making the zigbee network in the permitting joining mode. 2. Pressed the button of PAD06 three times in two seconds. the PAD06 will scan and try joining the network. * Reset to factory default / Leave network 1. Pressed the button three times in two seconds, and do not release the button in the 4th pressed without 5 seconds. 2. The device will leave the network, and LED will turn on. Warning: Do not use Non-Dimmable LED lamps. User Interface PAD06 is an E27(EU)/ E26(US) Edison screw based lamp socket, based on * Button Function Zigbee technology, which provides electrical connection to the E14(EU)/ E12(US) Edison screw based lamps and support it in the lighting fixture. The use of socket allows lamps to be safely and conveniently replaced. You can 1. Relay Control On/Off the light by pressing the button briefly, or a long pressing to control When pressed and released button, the PAD06 will control the relay in the brightness of dimmable light bulb. toggling way. For example, if you press the button then release and the relay is off, the device will turn the relay on. See the LED function for more information. 2. Dimmer Control Programming When long pressing button, the PAD06 will control the brightness of dimmable light bulb. * Zigbee Cluster Library Description 3. Join network The PAD06 support Profile Home Automation v1.2 (profile is is 0x0104). When pressed and released button three in 2 seconds, the PAD06 will do The device is hosted in endpoint 1 (0x01). finding and joining network. 4. Reset to default / Leave network * Supported Clusters List Pressed the button three times in two seconds, and do not release the button in the 4th pressed without 5 seconds, the PAD06 will do reset to default. * LED Function 1. Relay Status If the relay is on, the device will turn the LED on. Cluster ID Cluster Name 0x0000 Basic 0x0004 Group 0x0005 Scenes 0x0006 ON/OFF 0x0008 Level Control If the relay is off, the device will turn the LED off. * Basic Cluster (Cluster ID :0x0000) 2. Reset to default / Leave network Attribute ID When PAD06 reset to default / leave network the relay will turn on. 0x0500 3. Try joining network Power on the device, if PAD06 doesn't join network, the device will auto start the try joining network mode. The LED will light on one second. Attribute Name Model identifier Attribute Type CHAR Default Value * Group Cluster (Cluster ID :0x0004) * Level Control Cluster (Cluster ID :0x0008) 1. Read Current Level Request Request groupId : 0xABCD (by user) groupName : 0x00 (by user) Attrebute ID : 0x0000 Response Attrebute Data : 0x00(1 byte for current level) * Scenes Cluster (Cluster ID :0x0005) Request 2. Level Control sceneId : 0x01 (by user) extensionFieldSets : cluster id, length, value cluster id : scenes to do cluster id. length : value length. command id : 0x00 level : 0x00 (by user) transition time : 0x0000 (by user) 3. Level Control Move Mode command id : 0x01 movemode : 0x01 (turn on) , 0x00 (turn off) rate : 0x0A * ON/OFF Cluster (Cluster ID :0x0006) 1. Read Relay Status Request Attrebute ID : 0x0000 4. Level Control Step Response command id : 0x02 stepmode : 0x00 (turn on one step) , 0x01 (turn off one step) setpsize : 0x0A (by user) transition time : 0x0000 (by user) Attrebute Data : 0x00(OFF), 0x01(ON) 2. Control Relay Attrebute Date : 0x00(OFF), 0x01(ON) 5. Level Control Stop Over The Air (OTA) Firmware Update command id : 0x03 The device support the Zigbee firmware update via OTA. Before starting the procedure, please remove the front cover of the device. Otherwise the hardware check will be failed. 6. Level Control With ON/OFF command id : 0x04 level : 0x00 (by user) transition time : 0x0000 (by user) Choosing a Suitable Location 1. Do not locate the dimmer facing direct sunlight, humid or dusty place. 2. The suitable ambient temperature for the Switch is 0°C~40°C. 7. Level Control Move Mode With ON/OFF 3. Do not locate the dimmer where exists combustible substances or any source of command id : 0x05 movemode : 0x01 (turn on) , 0x00 (turn off) rate : 0x0A heat, e.g. fires, radiators, boiler etc. 4. After putting it into use, the body of dimmer will become a little bit hot of which phenomenon is normal. 8. Level Control Step With ON/OFF command id : 0x06 stepmode : 0x00 (turn on one step) , 0x01 (turn off one step) setpsize : 0x0A (by user) transition time : 0x0000 (by user) 9. Level Control Stop With ON/OFF command id : 0x07 Note: In level control cluster, all with on/off command can control PAD06 without relay on/off, but the eithers command only control when relay on. screw lamp holder Type: US TYPE: PAD06-2 Since the socket type for each country in Europe varies, refer to the outline for each socket suited for each country as follows: EU TYPE: PAD06-1 Note: Please make sure that the intensity of the screw lampholder of the electrical device must be Maximum Load (Ampere) and have same head as the enclosed screw lampholder before inserting to the socket. Troubleshooting Specification Symptom Cause of Failure Recommendation Operating Voltage: 100V~240V / 50Hz~60Hz The Switch not 1. The Switch is not 1. Check power connections Maximum Load (watts): 40W (Incandescent bulbs); ( PAD06-1; PAD06-2) 2. Don’t open up the Switch and send it for Maximum Load (watts): 13W (Dimmable LED bulbs); ( PAD06-1; PAD06-2) working and LED off plugged into the electrical outlet repair. Screw lamp holder Type: EU type: E27 to E14; PAD06-1 properly US type: E26 to E12; PAD06-2 2. The Switch break down The Switch LED 1.Check if the load illuminating, but plugged into the Switch cannot control the has its own ON/OFF ON/OFF switch Switch of the load 1. Set the ON/OFF switch of the load attached to ON 2. Unprotected the switch or follow the instruction of protection. 2. The switch is protected illuminating, but the Detector cannot control 1. Not carry out association 0°C ~ 40°C Frequency Range: 2405MHz~2475MHz(EU)(US/Canada)(TW/JP) RF Radiated Power: +1dBm Transmission Range: Minimum 40 m in door 100m outdoor line of sight Modulation Type: O-QPSK - Offset - Quadrature Phase Shift Keying ** Specifications are subject to change and improvement without notice. attached The Switch LED Operating Temperature: FCC ID : RHHPAD06 1. Carry out association 2. Wait for a while to re-try 2. Same frequency interference the Switch Warning: Do not use Non-Dimmable LED lamps. Warning: If this equipment does cause harmful interference to radio or television reception, which 1.Plug out to disconnect from power supply; Do not plug in line. can be determined by turning the equipment off and on, the user is encouraged to try to cor- 2. Do not exceed the max rating. rect the interference by one of the following measures: 3. Do not use Non-Dimmable LED lamps. • Reorient or relocate the receiving antenna. • Increase the separation between the equipment and receiver. Disposal • Connect the equipment into an outlet on a circuit different from that to which the receiver is This marking indicates that this product should not be disposed with connected. other household wastes throughout the EU. To prevent possible harm to • Consult the dealer or an experienced radio/TV technician for help. the environment or human health from uncontrolled waste disposal, This device complies with Part 15 of the FCC Rules. Operation is subject recycle it responsibly to promote the sustainable reuse of material to the following two conditions: resources. To return your used device, please use the return and (1) This device may not cause harmful interference, and collection systems or contact the retailer where the product was (2) This device must accept any interference received, including interference that may cause purchased. They can take this product for environmental safe recycling. undesired operation. Company of License Holder:Philio Technology Corporation FCC Caution: Any changes or modifications not expressly approved by the party responsible Address of License Holder:8F., No.653-2, Zhongzheng Rd., Xinzhuang Dist., New Taipei City for compliance could void the user's authority to operate this equipment. 24257, Taiwan(R.O.C) This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital de- FCC RF Exposure Information (SAR) vice, pursuant to Part 15 of the FCC Rules. 1. To comply with FCC RF exposure compliance requirements, a separation distance of at least These limits are designed to provide reasonable protection against harmful interference in a 20 cm must be maintained between the antenna of this device and all persons. residential installation. 2. This Transmitter must not be co-located or operating in conjunction with any other This equipment generates, uses and can radiate radio frequency energy and, if not installed antenna or transmitter. and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 7 Language : zh-TW Creator : Writer Producer : LibreOffice 5.0 Create Date : 2017:01:09 11:03:31+08:00EXIF Metadata provided by EXIF.tools