Philio Technology PAN03 Smart Energy In wall Switch User Manual BH002 RF ON OFF CONTROLLER
Philio Technology Corporation Smart Energy In wall Switch BH002 RF ON OFF CONTROLLER
(PAN03-2) UserMan
PAN03-1/-2/-3 Smart Energy In wall Switch Module house decoration. There are many kind of application by using the module to switch AC power On and Off , one main application is the light control. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of light like incandescent, fluorescent and LED light. This in-wall switch module is able to detect Instant power c (5~2500W)(11Ampere) and overload wattage (2700~2800W)(12 Ampere) of connected light or appliances. When detecting overload state, the Module will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, disconnect and re-connect the Module will reset its overload condition to normal status. Adding to Z-WaveTM Network In the front casing, there is an on/off button with LED indicator below which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 2second intervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices. Auto Inclusion Fig 1. Assembling This in-wall dual relay switch module is a transceiver which is a Z-WaveTM enabled The function of auto inclusion will be executed as long as the in wall switch does not device and is fully compatible with any Z-WaveTM enabled network. Mini size design have Node ID and just connect the switch to main power. let the module can easily hide itself into the wall box and that will be good for the Note: Auto inclusion timeout is 4 minute during which the node information of Reset 1. Pressing INCLUDE_BUTTON three explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as times within 1.5 seconds will enter shown in the table below, the execution of auto inclusion is free from pressing the inclusion mode. On/Off button on the Switch. 2. One press one flash Within 1 second, press On/Off button again for 5 seconds until LED is off. The table below lists an operation summary of basic Z-Wave functions. Please refer 3. to the instructions for your Z-WaveTM Certificated Primary Controller to access the IDs are excluded. 1. Have Z-Wave Controller entered Association Setup function, and to include/exclude/associate devices 2-second on, 2-second off One press one flash association mode. Or Pressing INCLUDE_BUTTON three Function Description LED Indication No node ID The Z-Wave Controller does not allocate 2-second on, 2-second off times within 1.5 seconds will enter association mode a node ID to the Switch. Inclusion 1. Have Z-Wave Controller entered 2. There are 3 groups for the switch One press one flash inclusion mode. ※Including a node ID allocated by Z-Wave Controller means inclusion. 2. Pressing INCLUDE_BUTTON three ID allocated by Z-Wave Controller means exclusion. times within 1.5 seconds will enter ※Failed or success in including/excluding the node ID can be viewed from the Z-Wave inclusion mode. Exclusion 1. Have Z-Wave Controller entered Excluding a node Controller. One press one flash exclusion mode. 2. Pressing INCLUDE_BUTTON three LED Indication times within 1.5 seconds will enter To distinguish what mode the switch is in, view from the LED for identification. exclusion mode. Node ID has been excluded. 2-second on, 2-second off State Type LED Indication Normal Whatever we switch On and off of the PAN03 by S1 S2 or On/Off button or RF command , the LED will lights up 1 second and then off. No node ID Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or On/Off button, it will stop flashing temporarily. However, after disconnect and reconnect the Switch, the LED will flash on and off alternately at 2-second intervals. Overload When overload state occurs, the Switch is disabled of which LED flashes on and off alternately at 0.5 second intervals. Overload state can be cleared by disconnect and reconnect the Switch to the main power Choosing a Suitable Location 1. Do not locate the Switch facing direct sunlight, humid or dusty place. 2. The suitable ambient temperature for the Switch is 0°C~40°C. 3. Do not locate the Switch where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc. 1. put the in wall switch into a wall box and connect the AC power wire L,N to 4. After putting it into use, the body of Switch will become a little bit hot of which PAN03 connector L, N. phenomenon is normal. Installation 2. Connect the wall switch to the PAN03 as Fig1 . 3. To manually turn ON the Switch, press and release the On/Off button. The LED will light ON for 1 second, and the load plugged into the Switch will also turn ON. Basic Get Command: [Command Class Basic, Basic Get] 4. To manually turn OFF the Switch, simply press and release the On/Off button. Basic Report Command: The LED will light ON for 1 second and the load plugged into the Switch will turn Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] OFF. Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF] Binary Switch Get Command:[Command Class Switch Binary, Switch Programming Binary Get] Binary Switch Report Command: 1. Basic Command Class / Binary Switch Command Class Report OFF:[Command Class Switch Binary, Switch Binary Report, Value The Switch will respond to BASIC and BINARY commands that are part of the Z- =0(0x00)] Wave system. Report ON:[Command Class Switch Binary, Switch Binary Report, Value = (255)0xFF] 1-1 BASIC_GET / BINARY_SWITCH_GET Since the switch have two relay, the Switch will report its On/Off state to the 1-2 BASIC_SET / SWITCH_BINARY_SET Controller by setting Configuration parameter 3. Upon receipt of the following commands from a Z-Wave Controller, the load attached to the Switch will turn on or off. Configuration parameter 3=1(default) Report ON either relay 1 ON or relay 2 ON [Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached Report OFF when both relay 1 and relay 2 OFF to the Switch turns on. Configuration parameter 3=2 Report ON when relay 1 ON [Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to Report OFF when relay 1 OFF the Switch turns off. Configuration parameter 3=3 Report ON when relay 2 ON [Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]: Report OFF when relay 2 OFF the load attached to the Switch turns on. [Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the load attached to the Switch turns off. When the power consumption of load vary over 5%, it will send Meter report to the nodes of Grouping 1. 2. Z-Wave’s Groups (Association Command Class Version 1) Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4] The Switch can be set to send reports to control associated Z-Wave devices. It supports one association group with one node support for Grouping 1. For grouping 1, the Switch will report its latest status to Z-Wave Controller. Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT_COMMAND 2-2 Response to Meter Get Command The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated 2-1 Auto report to Grouping 1 (Maximum Node 1) power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I ) (5) load power factor (PF) 2-1-1 On/Off Event Report to Z-Wave Controller after receive the Meter Get Command from Z-Wave Controller. When “on” or “off ” state has been changed, it will send Binary Switch Report to the nodes of Grouping 1. 2-2-1 Instant Power Consumption (Watt) of Switch Binary Switch Report When receiving Meter Get Command, it will report Meter Report Command to the node asked. ON:[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF] Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)] OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)] Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter 2-1-2 Instant Power Consumption vary over 5% report Value 1,Meter Value 2,Meter Value 3,Meter Value 4] Rate Type = 0x01 Meter Type = 0x01 Precision = 1 Scale = 0x02(W) Rate Type = 0x01 Size = 4 Bytes (Meter Value) Meter Type = 0x01 Meter Value 1 = (W) MSB Precision = 2 Meter Value 2 = (W) Scale = 0x00 (KWh) Meter Value 3 = (W) Size = 4 bytes (Meter Value) Meter Value 4 = (W)LSB Meter Value 1 = (W) MSB Meter Value 2 = (W) Example: Meter Value 3 = (W) Meter Value 1 = 0x00 (W) Meter Value 4 = (W) LSB Meter Value 2 = 0x00 (W) Meter Value 3 = 0x03 (W) Example: Meter Value 4 = 0xEA (W) Scale = 0x00 (KWh) Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W Precision = 2 Size = 4 Bytes (KW/h) 2-2-2 Accumulated Power Consumption (KW/h) Meter Value 1 = 0x00(W) When receiving Meter Get Command, it will report Meter Report Command to Meter Value 2 = 0x01(W) the node asked. Meter Value 3 = 0x38(W) Meter Value 4 = 0xA3(W) Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value KW/h)] Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4] 3*256) + (Meter Value 4) = 800.35 (KW/h) 2-2-3 Clearing accumulated power consumption Example: Scale = 0x04 (V) Precision = 1 Meter Reset Command: [Command Class Meter, Meter Reset] Size = 2 (2 Bytes of V) Meter Value 1 = 0x09(V) Meter Value 2 = 0x01(V) 2-2-4 AC load Voltage (V) AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V) When receiving Meter Get Command, it will report Meter Report Command to the node asked. 2-2-5 AC load current ( I ) When receiving Meter Get Command, it will report Meter Report Command to the Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)] node asked. Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2] Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)] Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2] Rate Type = 0x01 Meter Type = 0x01 Precision = 1 Scale = 0x04(V) Size = 2 Bytes (Meter Value) Rate Type = 0x01 Meter Value 1 = High Byte (V) Meter Type = 0x01 Meter Value 2 = Low Byte (V) Precision = 2 Scale = 0x05(I) Size = 2 Bytes (Meter Value) Meter Value 1 = High Byte (I) Scale = 0x06(PF) Meter Value 2 = Low Byte (I) Size = 1 Bytes Meter Value 1 Example: Scale = 0x05 (I) Example: Precision = 2 Scale = 0x06 (PF) Size = 2 (2 Bytes of I) Precision = 2 Meter Value 1 = 0x01(I) Size = 1 (1 Byte of PF) Meter Value 2 = 0x21(I) Meter Value 1 = 0x63(PF) AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A) Load power factor (PF) = Meter Value 1 =0.99 2-2-6 load power factor (PF) When receiving Meter Get Command, it will report Meter Report Command to the 3-1 Watt Meter Report Period: node asked. If the setting is configured for 1hour (set value =720), the PAN03 will report its instant power consumption every 1 hour to the node of correspond Group. The Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)] maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). 3-2 KWH Meter Report Period: Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1] If the setting is configured for 1hour (set value =6), the PAN03 will report its Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond Group. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Rate Type = 0x01 Meter Type = 0x01 Precision = 2 The Switch LED 4. Command Classes 1. Not carry out illuminating, but the association Detector cannot control 1. Carry out association 2. Wait for a while to re-try 2. Same frequency The Switch supports Command Classes including… the Switch * COMMAND_CLASS_SWITCH_BINARY LED keep flashing 30 * COMMAND_CLASS_BASIC seconds, but cannot control interference Overload occurs * COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 Remove the load attached or check max. load cannot exceed 2500W~2700W * COMMAND_CLASS_VERSION * COMMAND_CLASS_SWITCH_ALL Specification * COMMAND_CLASS_ASSOCIATION_V1 Operating Voltage * COMMAND_CLASS_METER_V3 Maximum Load * COMMAND_CLASS_CONFIGURATION Range 100 ~240VAC 11A (Ampere) Minimum 30 m in door 100m outdoor line of sight Operating Temperature 0°C ~ 40°C Troubleshooting Frequency Range PAN03-1: 868.40MHz; 869.85MHz(EU) / PAN03-2 908.40MHz; 916.00MHz(USA/Canada) / Symptom Cause of Failure Recommendation The Switch not working and 1. The Switch is not 1. Check power connections LED off 2. Don’t open up the Switch and connect to the Main power PAN03-3 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP) ** Specifications are subject to change and improvement without notice. send it for repair. FCC ID : RHHPAN03 2. The Switch break down The Switch LED Check if the load connect Set the ON/OFF switch of the load illuminating, but cannot into the Switch has its control the ON/OFF own ON/OFF switch attached to ON Switch of the load attached Warning: If this equipment does cause harmful interference to radio or television reception, which 1.Plug out to disconnect from power supply; Do not plug in line. can be determined by turning the equipment off and on, the user is encouraged to try to cor- 2. Do not exceed the max rating rect the interference by one of the following measures: • Reorient or relocate the receiving antenna. Disposal • Increase the separation between the equipment and receiver. This marking indicates that this product should not be disposed with • Connect the equipment into an outlet on a circuit different from that to which the receiver is other household wastes throughout the EU. To prevent possible harm to connected. the environment or human health from uncontrolled waste disposal, • Consult the dealer or an experienced radio/TV technician for help. recycle it responsibly to promote the sustainable reuse of material This device complies with Part 15 of the FCC Rules. Operation is subject resources. To return your used device, please use the return and to the following two conditions: collection systems or contact the retailer where the product was (1) This device may not cause harmful interference, and purchased. They can take this product for environmental safe recycling. (2) This device must accept any interference received, including interference that may cause Company of License Holder:Philio Technology Corporation undesired operation. Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New FCC Caution: Any changes or modifications not expressly approved by the party responsible Taipei City 24257,Taiwan(R.O.C) for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. FCC Interference Statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. 10
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Page Count : 10 Language : zh-TW Title : BH002 RF ON/OFF CONTROLLER Author : . Creator : Writer Producer : LibreOffice 4.1 Create Date : 2014:07:03 15:38:27+08:00EXIF Metadata provided by EXIF.tools