Philio Technology PAN03 Smart Energy In wall Switch User Manual BH002 RF ON OFF CONTROLLER

Philio Technology Corporation Smart Energy In wall Switch BH002 RF ON OFF CONTROLLER

(PAN03-2) UserMan

Download: Philio Technology PAN03 Smart Energy In wall Switch User Manual BH002  RF ON OFF CONTROLLER
Mirror Download [FCC.gov]Philio Technology PAN03 Smart Energy In wall Switch User Manual BH002  RF ON OFF CONTROLLER
Document ID2410920
Application IDmjhbNWh17XMs/L9LGK10FA==
Document Description(PAN03-2) UserMan
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize15.47kB (193342 bits)
Date Submitted2014-10-06 00:00:00
Date Available2014-10-06 00:00:00
Creation Date2014-07-03 15:38:27
Producing SoftwareLibreOffice 4.1
Document Lastmod0000-00-00 00:00:00
Document TitleBH002 RF ON/OFF CONTROLLER
Document CreatorWriter
Document Author: .

PAN03-1/-2/-3 Smart Energy In wall Switch Module
house decoration.
There are many kind of application by using the module to switch AC power On and
Off , one main application is the light control. The new smart relay calibration
technology can reduce the inrush current caused by the load and let the module work
perfectly with many kind of light like incandescent, fluorescent and LED light.
This in-wall switch module is able to detect Instant power c (5~2500W)(11Ampere)
and overload wattage (2700~2800W)(12 Ampere) of connected light or appliances.
When detecting overload state, the Module will be disabled and its On/Off button will
be lockout of which LED will flash quickly. However, disconnect and re-connect the
Module will reset its overload condition to normal status.
Adding to Z-WaveTM Network
In the front casing, there is an on/off button with LED indicator below which is used to
toggle switch on and off or carry out inclusion, exclusion, reset or association. When
first power is applied, its LED flashes on and off alternately and repeatedly at 2second intervals. It implies that it has not been assigned a node ID and cannot work
with Z-Wave enabled devices.
Auto Inclusion
Fig 1. Assembling
This in-wall dual relay switch module is a transceiver which is a Z-WaveTM enabled
The function of auto inclusion will be executed as long as the in wall switch does not
device and is fully compatible with any Z-WaveTM enabled network. Mini size design
have Node ID and just connect the switch to main power.
let the module can easily hide itself into the wall box and that will be good for the
Note: Auto inclusion timeout is 4 minute during which the node information of
Reset
1.
Pressing INCLUDE_BUTTON three
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as
times within 1.5 seconds will enter
shown in the table below, the execution of auto inclusion is free from pressing the
inclusion mode.
On/Off button on the Switch.
2.
One press one flash
Within 1 second, press On/Off
button again for 5 seconds until LED
is off.
The table below lists an operation summary of basic Z-Wave functions. Please refer
3.
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
IDs are excluded.
1. Have Z-Wave Controller entered
Association
Setup function, and to include/exclude/associate devices
2-second on, 2-second off
One press one flash
association mode.
Or Pressing INCLUDE_BUTTON three
Function
Description
LED Indication
No node ID
The Z-Wave Controller does not allocate
2-second on, 2-second off
times within 1.5 seconds will enter
association mode
a node ID to the Switch.
Inclusion
1.
Have Z-Wave Controller entered
2. There are 3 groups for the switch
One press one flash
inclusion mode.
※Including a node ID allocated by Z-Wave Controller means inclusion.
2. Pressing INCLUDE_BUTTON three
ID allocated by Z-Wave Controller means exclusion.
times within 1.5 seconds will enter
※Failed or success in including/excluding the node ID can be viewed from the Z-Wave
inclusion mode.
Exclusion
1.
Have Z-Wave Controller entered
Excluding a node
Controller.
One press one flash
exclusion mode.
2.
Pressing INCLUDE_BUTTON three
LED Indication
times within 1.5 seconds will enter
To distinguish what mode the switch is in, view from the LED for identification.
exclusion mode.
Node ID has been excluded.
2-second on, 2-second off
State Type
LED Indication
Normal
Whatever we switch On and off of the PAN03 by S1 S2 or On/Off
button or RF command , the LED will lights up 1 second and then
off.
No node ID
Under normal operation, when the Switch has not been allocated a
node ID, the LED flashes on and off alternately at 2-second
intervals. By pressing S1 S2 or On/Off button, it will stop flashing
temporarily. However, after disconnect and reconnect the Switch,
the LED will flash on and off alternately at 2-second intervals.
Overload
When overload state occurs, the Switch is disabled of which LED
flashes on and off alternately at 0.5 second intervals. Overload
state can be cleared by disconnect and reconnect the Switch to
the main power
Choosing a Suitable Location
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the Switch is 0°C~40°C.
3. Do not locate the Switch where exists combustible substances or any source of
heat, e.g. fires, radiators, boiler etc.
1. put the in wall switch into a wall box and connect the AC power wire L,N to
4. After putting it into use, the body of Switch will become a little bit hot of which
PAN03 connector L, N.
phenomenon is normal.
Installation
2. Connect the wall switch to the PAN03 as Fig1 .
3. To manually turn ON the Switch, press and release the On/Off button. The LED
will light ON for 1 second, and the load plugged into the Switch will also turn ON.
Basic Get Command: [Command Class Basic, Basic Get]
4. To manually turn OFF the Switch, simply press and release the On/Off button.
Basic Report Command:
The LED will light ON for 1 second and the load plugged into the Switch will turn
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
OFF.
Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]
Binary Switch Get Command:[Command Class Switch Binary, Switch
Programming
Binary Get]
Binary Switch Report Command:
1. Basic Command Class / Binary Switch Command Class
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value
The Switch will respond to BASIC and BINARY commands that are part of the Z-
=0(0x00)]
Wave system.
Report ON:[Command Class Switch Binary, Switch Binary Report, Value =
(255)0xFF]
1-1 BASIC_GET / BINARY_SWITCH_GET
Since the switch have two relay, the Switch will report its On/Off state to the
1-2 BASIC_SET / SWITCH_BINARY_SET
Controller by setting Configuration parameter 3.
Upon receipt of the following commands from a Z-Wave Controller, the load
attached to the Switch will turn on or off.
Configuration parameter 3=1(default) Report ON either relay 1 ON or relay 2
ON
[Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached
Report OFF when both relay 1 and relay 2 OFF
to the Switch turns on.
Configuration parameter 3=2 Report ON when relay 1 ON
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to
Report OFF when relay 1 OFF
the Switch turns off.
Configuration parameter 3=3 Report ON when relay 2 ON
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:
Report OFF when relay 2 OFF
the load attached to the Switch turns on.
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the
load attached to the Switch turns off.
When the power consumption of load vary over 5%, it will send Meter report to the
nodes of Grouping 1.
2. Z-Wave’s Groups (Association Command Class Version 1)
Meter Report Command: [Command Class Meter,Meter
Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit
1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value
4]
The Switch can be set to send reports to control associated Z-Wave devices. It
supports one association group with one node support for Grouping 1. For grouping
1, the Switch will report its latest status to Z-Wave Controller.
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT_COMMAND
2-2 Response to Meter Get Command
The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated
2-1 Auto report to Grouping 1 (Maximum Node 1)
power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I )
(5) load power factor (PF)
2-1-1 On/Off Event Report
to Z-Wave Controller after receive the Meter Get
Command from Z-Wave Controller.
When “on” or “off ” state has been changed, it will send Binary Switch Report to the
nodes of Grouping 1.
2-2-1 Instant Power Consumption (Watt) of Switch
Binary Switch Report
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
ON:[Command Class Switch Binary, Switch Binary Report, Value
=(255)0xFF]
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
OFF:[Command Class Switch Binary, Switch Binary Report, Value
=0(0x00)]
Meter Report Command: [Command Class Meter,Meter Report,scale(bit
2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter
2-1-2 Instant Power Consumption vary over 5% report
Value 1,Meter Value 2,Meter Value 3,Meter Value 4]
Rate Type = 0x01
Meter Type = 0x01
Precision = 1
Scale = 0x02(W)
Rate Type = 0x01
Size = 4 Bytes (Meter Value)
Meter Type = 0x01
Meter Value 1 = (W) MSB
Precision = 2
Meter Value 2 = (W)
Scale = 0x00 (KWh)
Meter Value 3 = (W)
Size = 4 bytes (Meter Value)
Meter Value 4 = (W)LSB
Meter Value 1 = (W) MSB
Meter Value 2 = (W)
Example:
Meter Value 3 = (W)
Meter Value 1 = 0x00 (W)
Meter Value 4 = (W) LSB
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Example:
Meter Value 4 = 0xEA (W)
Scale = 0x00 (KWh)
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
Precision = 2
Size = 4 Bytes (KW/h)
2-2-2 Accumulated Power Consumption (KW/h)
Meter Value 1 = 0x00(W)
When receiving Meter Get Command, it will report Meter Report Command to
Meter Value 2 = 0x01(W)
the node asked.
Meter Value 3 = 0x38(W)
Meter Value 4 = 0xA3(W)
Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00
Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value
KW/h)]
Meter Report Command: [Command Class Meter,Meter
Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit
1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value
4]
3*256) + (Meter Value 4) = 800.35 (KW/h)
2-2-3 Clearing accumulated power consumption
Example:
Scale = 0x04 (V)
Precision = 1
Meter Reset Command: [Command Class Meter, Meter Reset]
Size = 2 (2 Bytes of V)
Meter Value 1 = 0x09(V)
Meter Value 2 = 0x01(V)
2-2-4 AC load Voltage (V)
AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
2-2-5 AC load current ( I )
When receiving Meter Get Command, it will report Meter Report Command to the
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]
node asked.
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]
Rate Type = 0x01
Meter Type = 0x01
Precision = 1
Scale = 0x04(V)
Size = 2 Bytes (Meter Value)
Rate Type = 0x01
Meter Value 1 = High Byte (V)
Meter Type = 0x01
Meter Value 2 = Low Byte (V)
Precision = 2
Scale = 0x05(I)
Size = 2 Bytes (Meter Value)
Meter Value 1 = High Byte (I)
Scale = 0x06(PF)
Meter Value 2 = Low Byte (I)
Size = 1 Bytes
Meter Value 1
Example:
Scale = 0x05 (I)
Example:
Precision = 2
Scale = 0x06 (PF)
Size = 2 (2 Bytes of I)
Precision = 2
Meter Value 1 = 0x01(I)
Size = 1 (1 Byte of PF)
Meter Value 2 = 0x21(I)
Meter Value 1 = 0x63(PF)
AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)
Load power factor (PF) = Meter Value 1 =0.99
2-2-6 load power factor (PF)
When receiving Meter Get Command, it will report Meter Report Command to the
3-1 Watt Meter Report Period:
node asked.
If the setting is configured for 1hour (set value =720), the PAN03 will report its
instant power consumption every 1 hour to the node of correspond Group. The
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]
maximum interval to report its instant power consumption is 45 hours
(5s*32767/3600=45hr).
3-2 KWH Meter Report Period:
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1]
If the setting is configured for 1hour (set value =6), the PAN03 will report its
Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond
Group. The maximum interval to report its Accumulated Power Consumption
(KW/h) is 227.55 days (10min*32767/1440=227.55 days).
Rate Type = 0x01
Meter Type = 0x01
Precision = 2
The Switch LED
4.
Command Classes
1. Not carry out
illuminating, but the
association
Detector cannot control
1. Carry out association
2. Wait for a while to re-try
2. Same frequency
The Switch supports Command Classes including…
the Switch
* COMMAND_CLASS_SWITCH_BINARY
LED keep flashing 30
* COMMAND_CLASS_BASIC
seconds, but cannot control
interference
Overload occurs
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
Remove the load attached or check
max. load cannot exceed
2500W~2700W
* COMMAND_CLASS_VERSION
* COMMAND_CLASS_SWITCH_ALL
Specification
* COMMAND_CLASS_ASSOCIATION_V1
Operating Voltage
* COMMAND_CLASS_METER_V3
Maximum Load
* COMMAND_CLASS_CONFIGURATION
Range
100 ~240VAC
11A (Ampere)
Minimum 30 m in door 100m outdoor line of sight
Operating Temperature 0°C ~ 40°C
Troubleshooting
Frequency Range
PAN03-1: 868.40MHz; 869.85MHz(EU) /
PAN03-2 908.40MHz; 916.00MHz(USA/Canada) /
Symptom
Cause of Failure
Recommendation
The Switch not working and 1. The Switch is not
1. Check power connections
LED off
2. Don’t open up the Switch and
connect to the Main
power
PAN03-3 922.5MHz/ 923.9MHz/ 926.3MHz (Taiwan/JP)
** Specifications are subject to change and improvement without notice.
send it for repair.
FCC ID : RHHPAN03
2. The Switch break
down
The Switch LED
Check if the load connect Set the ON/OFF switch of the load
illuminating, but cannot
into the Switch has its
control the ON/OFF
own ON/OFF switch
attached to ON
Switch of the load attached
Warning:
If this equipment does cause harmful interference to radio or television reception, which
1.Plug out to disconnect from power supply; Do not plug in line.
can be determined by turning the equipment off and on, the user is encouraged to try to cor-
2. Do not exceed the max rating
rect the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
Disposal
• Increase the separation between the equipment and receiver.
This marking indicates that this product should not be disposed with
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
other household wastes throughout the EU. To prevent possible harm to
connected.
the environment or human health from uncontrolled waste disposal,
• Consult the dealer or an experienced radio/TV technician for help.
recycle it responsibly to promote the sustainable reuse of material
This device complies with Part 15 of the FCC Rules. Operation is subject
resources. To return your used device, please use the return and
to the following two conditions:
collection systems or contact the retailer where the product was
(1) This device may not cause harmful interference, and
purchased. They can take this product for environmental safe recycling.
(2) This device must accept any interference received, including interference that may cause
Company of License Holder:Philio Technology Corporation
undesired operation.
Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New
FCC Caution: Any changes or modifications not expressly approved by the party responsible
Taipei City 24257,Taiwan(R.O.C)
for compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
FCC Interference Statement
This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to
radio communications.
However, there is no guarantee that interference will not occur in a particular installation.
10

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 10
Language                        : zh-TW
Title                           : BH002  RF ON/OFF CONTROLLER
Author                          : .
Creator                         : Writer
Producer                        : LibreOffice 4.1
Create Date                     : 2014:07:03 15:38:27+08:00
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RHHPAN03

Navigation menu