Philio Technology PAN08 In Wall Switch User Manual BH002 RF ON OFF CONTROLLER

Philio Technology Corporation In Wall Switch BH002 RF ON OFF CONTROLLER

Users Manual

PAN08-1/-2/-3  Roller shutter controllerP        Fig 1. Assembling The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter connected to its terminals using radio waves, controllers and a push button directly connected to this Roller Controller.This in-wall Roller Shutter Controller is a transceiver which is a Z-WaveTM enabled device and is fully compatible with any Z-WaveTM enabled network. Slim design let the Controller can easily hide itself into the wall box and that will be good for the house decoration. The new smart relay calibration technology can reduce the inrush current caused by the load and let the module work perfectly with many kind of Roller Shutter.  This in-wall Roller Shutter Controller is able to detect position of the Shutter by usingthe patterned power measuring method, so it can be remote controlled not only fullyup   or   down   ,   but   also   can   be   adjusted   to   ex.   30%   or   50%.  And   when   manualcontrolled by push button, the controller also can memorize the position and send thenew shutter position to its controller (ex. IP-Gateway).Adding to Z-WaveTM NetworkIn the front casing, there is an include button with LED indicator below which is usedto carry out inclusion, exclusion, reset or association. When first power is applied, itsLED flashes on and off alternately and repeatedly at 2-second intervals. It impliesthat  it has  not   been  assigned  a  node  ID  and  cannot  work  with  Z-Wave  enableddevices. Auto InclusionThe function of auto inclusion will be executed as long as the PAN08 does not have Node ID and just connect the PAN08 to main power.Note: Auto inclusion timeout is 4 minute during which the node information of 1
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the Include button on the PAN08.The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devicesFunction Description LED IndicationNo node ID The Z-Wave Controller does not allocatea node ID to the PAN08.2-second on, 2-second offInclusion 1. Have Z-Wave Controller entered inclusion mode.One press one flash2.  Pressing Include button three times within 1.5 seconds will enter inclusion mode.Exclusion 1. Have Z-Wave Controller entered exclusion mode.One press one flash2. Pressing Include button three times within 1.5 seconds will enter exclusion mode.Node ID has been excluded. 2-second on, 2-second offReset 1. Pressing Include button three times within 1.5 seconds will enter inclusion mode.One press one flash2. Within 1 second, press Include button again for 5 seconds until LEDis off.3. IDs are excluded. 2-second on, 2-second offAssociation 1. Have Z-Wave Controller entered association mode.Or  Pressing Include button three times within 1.5 seconds will enter association modeOne press one flash2.  There are 1 group (Group 1) for the PAN08※Including a node ID allocated by Z-Wave Controller means inclusion.  Excluding a nodeID allocated by Z-Wave Controller means exclusion.※Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller. LED IndicationTo distinguish what mode the PAN08 is in, view from the LED for identification.State Type LED IndicationMotor activateNo matter up or down, close or open, Led will flash every second while Motor activate.No node ID Under normal operation, when the PAN08 has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing S1 S2 or Include button, it will stop flashing temporarily. However, after disconnect and reconnect the PAN08, the LED will flash on and off alternately at 2-second intervals.2
Overload When overload state occurs, the PAN08 is disabled of which LED flashes on and off alternately at 0.5 second intervals. Overload state can be cleared by disconnect and reconnect the PAN08 to the main powerChoosing a Suitable Location1. Do not locate the PAN08 facing direct sunlight, humid or dusty place.2. The suitable ambient temperature for the PAN08 is 0°C~40°C.3. Do not locate the PAN08 where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.4. After putting it into use, the body of PAN08 will become a little bit hot of which phenomenon is normal.Installation and operation1. put the in wall PAN08 into a wall box and connect the AC power wire L,N toPAN08 connector L, N.2. Connect the wall switch to the PAN08 as Fig1 .3. It is important to carry out a shutter calibration process before you control theshutter to move. Press inclusion button over 3 seconds and release before the6th second, the roller shutter controller will start the shutter calibration process.The process is composed of three continue stages. The shutter move to the TOPin first stage, and move to the BOTTOM in second stage, and move to the TOPagain in third stage. Then PAN08 will know the total range of UP and DOWN.4. During the shutter calibration process, any emergencies happen  you can pressand release the include button to stop the process 5. If user found the direction is reverse, this may because the wrong connection ofNC and NO to the motor, please change NC and NO connection and executecalibration process again.3
6. To manually switch up and down of the shutter, simply press S1 or S2 .7. PAN08   built   in   meter   function   and   can   read   the   Watt   ,   KWh,   V(Voltage),I(Current) , PF(Power Factor) of the load by using Z-Wave command class, usercan set a threshold watt to get the warning caused by abnormal operation 8. PAN08 have overload protection function, and can help to prevent short circuitcaused by load.Programming1.  Basic Command Class The PAN08 will respond to BASIC and BINARY commands that are part of theZ-Wave system.1.1 BASIC_GET When PAN08 receive Basic Set Command,it will send Basic Report Command to report the position of the curtain。 When the report value is 0x00, that mean the Shutter is bottom down, if the report value is 0xFF or 0x63  that mean the Shutter is at the top, any other value between0x01~0x62 imply Shutter at 1%~99% position;But if report value is 0xFE means the position is unknown。    Basic Get Command: [Command Class Basic, Basic Get]Basic Report Command:[Command Class Basic, Basic Report, Value = 0x00 (BOTTOM)][Command Class Basic, Basic Report, Value = 0x01~0x62 (Between BOT-TOM and TOP)][Command Class Basic, Basic Report, Value = 0xFE (UNKNOWN)][Command Class Basic, Basic Report, Value = 0x63/0xFF (TOP)]1-2 BASIC_SET PAN08 can only accept  Basic Set Command which value is either (0x00)Bottom or Top (0x63/0xFF),other value is not acceptable  [Command Class Basic, Basic Set, Value = 0x63 或0xFF] control the shutter to the top (0xFF)。[Command Class Basic, Basic Set, Value = 0x00(0)] control the shutter tothe bottom(0x00)。2 Binary Switch Command Class4
2-1 BINARY_SWITCH_GET,When PAN08 receive Binary Switch Get Command, it will send Binary Switch Report Command to report the position of the curtain. When the report value is 0x00, that mean the Shutter is bottom down, if the report value is 0xFF that mean the Shutter is at the top. But if report value is 0xFE means the position is unknown.2-2 BINARY_SWITCH_SETPAN08 can only accept Binary Switch Set Command which value is either (0x00) Bottom or Top (0xFF),other value is not acceptable。 3. Multilevel Switch Command Class (Version 3):3-1 MULTILEVEL SWITCH SET:PAN08 can only accept Multilevel Switch Set Command which value is either (0x00)Bottom or Top (0x63 or 0xFF),other value is not acceptable。[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x63 or 0xFF(255)] control the shutter to the top (0xFF)。[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x00(0)] control the shutter to the bottom(0x00)。3-2 MULTILEVEL SWITCH GET:When PAN08 receive Multilevel Switch Get Command, it will send Multilevel Switch Report Command to report the position of the shutter. When the report value is 0x00, that mean the shutter is bottom down, if the report value is 0xFF or 0x63  that mean the shutter is at the top, any other value between0x01~0x62 imply shutter at 1%~99% position;But if report value is 0xFE means the position is unknown.Switch Multilevel Get Command:[Command Class Multilevel Switch, Multilevel Switch Get]Multilevel Switch Report Comman:[Command Class Multilevel Switch, Multilevel Switch Report, Value = 0x00(BOTTOM)][Command Class Multilevel Switch, Multilevel Switch Report, Value = 0x01~0x62(Between BOTTOM and TOP)][Command Class Multilevel Switch, Multilevel Switch Report, 5Binary Switch Get Command:[Command Class Binary Switch, Binary Switch Get]Binary Switch Report  Command:[Command Class Binary Switch, Binary Switch Report, Value = 0x00(BOTTOM)][Command Class Binary Switch, Binary Switch Report, Value = 0xFE(UN-KNOWN)][Command Class Binary Switch, Binary Switch Report, Value = 0xFF(TOP)][Command Class Binary Switch, Binary Switch Set, Value = 0xFF(255)]control the shutter to the top (0xFF)。But if the shutter is on the way down, this command will stop the shutter。[Command Class Binary Switch, Binary Switch Set, Value = 0x00(0)]control the shutter to the bottom(0x00)。But if the shutter is on the way up, this com-mand will stop the shutter。
Value = 0xFE(UNKNOWN)][Command Class Multilevel Switch, Multilevel Switch Report, Value = 0x63/0xFF(TOP)]3-3 MULTILEVEL SWITCH START LEVEL CHANGE:This is the command which user can move the shutter to the particular posi-tion ex. 60% of total range[Command Class Multilevel Switch, Multilevel Switch Start Level Change, Up/Down Value , Inc/Dec Value, Step Size Value]。3-3.1 Up/Down Bit :If Up/Down Bit=0x00 Shutter move up;If Up/Down Bit=0x01 Shutter move down;If Up/Down Bit=0x03 no move3-3.2 Inc/Dec Bit:If Inc/Dec Bit=0x00 means New Step_Size = Now Step_Size + Step_Size ;If Inc/Dec Bit=0x01 means New Step_Size = Now Step_Size - Step_Size ;If Inc/Dec Bit=0x03 means New Step_Size = Now Step_Size 3-3.3 Step_Size:Range from 0x00~0x63 or 0xFF, default value=50, and the meaning of 0x63 and 0xFF is 100% of total range. If the Now Step_Size + Step_Size >100, the new Step_Size will stay at 100 , if  the Now Step_Size - Step_Size <0 , the New Step_Size will stay at 0Example 1:If user want shutter move up , and the distance is 60% of total range(assume the now Step_Size= 50)Command Class Multilevel SwitchMultilevel Switch Start Level ChangeUp/Down = 0x00 (UP = 0x00)Inc/Dec = 0x00 (Increment = 0x00:Step_Size = 50+10 = 60)Step_Size = 10 This value represent how many the new step_size want to increase or decreaseExample 2: If user want shutter move down , and the distance is 50% of total range(assume the now Step_Size= 50)Command Class Multilevel SwitchMultilevel Switch Start Level ChangeUp/Down = 0x01 (Down = 0x01)Inc/Dec = 0x03 (No Inc/Dec = 0x03:not change Step_Size value,Step_Size = 50)Step_Size = 0 This value represent how many the new step_size want to increase or decrease, when Inc/Dec = 0x03 please set this value to 0)6
Example 3:If User not go to change shutter position but only change Step_Size to 40%( assume the now Step_Size= 50)Command Class Multilevel SwitchMultilevel Switch Start Level ChangeUp/Down = 0x03 (No Up/Down motion = 0x03)Inc/Dec = 0x01 (Decrement = 0x01:Step_Size = 50–10 = 40)Step_Size = 10 This value represent how many the new step_size want to increase or decreaseATT.1. Ignore_Start_Level、Start_Level、Dimming_Duration can not be used 2. PAN08 can not control the speed of motor。3-3.4 MULTILEVEL SWITCH STOP LEVEL CHANGE:When receive Multilevel Switch Stop Level change Command PAN08 will stop the motor。4 Z-wave’s Groups introduction (Association Command Class Version 1 )There is only one group called Group1,there is only one node for Group1 which support MULTILEVEL_SWITCH_REPORT、METER_REPORT_COMMAND_V3、 ALARM_REPORT。 4-1 Report the shutter position :Every time when user press S1 or S2 and let shutter to move, PAN08 will report the position status to controller, and at the moving process when change over 10%  PAN08 will send Multilevel Switch Report to Group 1 also.Multilevel Switch Report:Ex. Report position at 30% [Command Class Multilevel Switch, Multilevel Switch Report,Value = 30(%)]4-2 Meter Command Class:The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulatedpower consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I )(5) load  power  factor  (PF)    to  Z-Wave   Controller   after  receive   the   Meter   GetCommand from Z-Wave Controller.When the power consumption of load vary over 5%, it will send Meter report to thenodes of Group as well4-2.1 Instant Power Consumption (Watt) of Switch    When receiving Meter Get Command, it will report Meter Report Command to thenode asked.Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)] Meter Report Command: [Command Class Meter,Meter Report,scale(bit2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4]Rate Type = 0x01Meter Type = 0x01Precision = 1Scale = 0x02(W)Size = 4 Bytes (Meter Value)Meter Value 1 = (W) MSB7
Meter Value 2 = (W)Meter Value 3 = (W)Meter Value 4 = (W)LSBExample:Meter Value 1 = 0x00 (W)Meter Value 2 = 0x00 (W)Meter Value 3 = 0x03 (W)Meter Value 4 = 0xEA (W)Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W4-2.2 Accumulated Power Consumption (KW/h)When receiving Meter Get Command, it will report Meter Report Command tothe node asked.Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 KW/h)]    Rate Type = 0x01     Meter Type = 0x01     Precision = 2     Scale = 0x00 (KWh)     Size = 4 bytes (Meter Value)     Meter Value 1 = (KWh) MSB     Meter Value 2 = (KWh)      Meter Value 3 = (KWh)     Meter Value 4 = (KWh) LSB     Example:     Scale = 0x00 (KWh)     Precision = 2     Size = 4 Bytes (KW/h)     Meter Value 1 = 0x00(KWh)     Meter Value 2 = 0x01(KWh)     Meter Value 3 = 0x38(KWh)     Meter Value 4 = 0xA3(KWh)     Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value3*256) + (Meter Value 4) = 800.35 (KW/h)4-2.3 AC load Voltage (V)    When receiving Meter Get Command, it will report Meter Report Command to thenode asked.  Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]  8Meter Report Command:[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +MeterType,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4]
Rate Type = 0x01Meter Type = 0x01Precision = 1Scale = 0x04(V)Size = 2 Bytes (Meter Value)Meter Value 1 = High Byte (V)Meter Value 2 = Low Byte (V)Example:Scale = 0x04 (V)Precision = 1 Size = 2 (2 Bytes of  V)Meter Value 1 =  0x09(V)Meter Value 2 =  0x01(V)AC load Voltage =  (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)4-2.4 AC load current ( I )    When receiving Meter Get Command, it will report Meter Report Command to thenode asked.  Rate Type = 0x01Meter Type = 0x01Precision = 2Scale = 0x05(I)Size = 2 Bytes (Meter Value)Meter Value 1 = High Byte (I)Meter Value 2 = Low Byte (I)Example:Scale = 0x05 (I)Precision = 2 Size = 2 (2 Bytes of I)Meter Value 1 =  0x01(I)Meter Value 2 =  0x21(I)AC load current =  (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)4-2.5 load power factor (PF)    When receiving Meter Get Command, it will report Meter Report Command to thenode asked.9Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]Meter Report Command:[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]
Rate Type = 0x01Meter Type = 0x01Precision = 2Scale = 0x06(PF)Size = 1 Bytes Meter Value 1 Example:Scale = 0x06 (PF)Precision = 2Size = 1 (1 Byte of  PF)Meter Value 1 =  0x63(PF)Load power factor (PF) = Meter Value 1 = 0.994-2.6 reset Accumulated Power Consumption (KWh)This command is to reset the Accumulated Power Consumption (KWh) to 0Meter Reset Command:[Command Class Meter, Meter Reset]4-3 Alarm Report Command:When PAN08 detect Overload,it will send Alarm_Report to Group1,Alarm Level=0xFF。When receive Alarm_Get command and the PAN08 not in overload sta-tus , it will send Alarm_Report,Alarm Level=0x00。4-3.1 Alarm Report:[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0xFF (Overload)][Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0x00 (Normal)]5 Z-Wave’s ConfigurationConfigurationParameterFunction Size(Byte)Value Unit Default Description1 Watt Meter Report  Period2 0x01-0x7FFF5s 720 5*720s=3600s=1hour2 KWH Meter 2 0x01-0x7FFF10min 6 6*10min= 1 hour10Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1]
Report  Period3 Thresholdof Watt for Load Caution2 10-1100 1watt 11004 Thresholdof KWH for Load Caution2 1-10000 1KWh 100005-1 Watt Meter Report Period:    If the setting is configured for 1hour (set value =720), the PAN08 will report itsinstant power consumption every 1 hour to the node of correspond Group.  Themaximum   interval   to   report   its   instant   power   consumption   is   45   hours(5s*32767/3600=45hr). Default value is 1 hour5-2 KWH Meter Report Period:      If   the  setting  is   configured  for 1hour  (set  value  =6),  the  PAN08  will report  itsAccumulated Power Consumption (KW/h) every 1 hour to the node of correspondGroup.   The  maximum  interval   to  report  its Accumulated  Power  Consumption(KW/h) is 227.55 days (10min*32767/1440=227.55 days). Default value=1 hour5-3 Threshold of Watt for Load CautionThis is a warning when the wattage of load over the preset threshold value, If the setting value is 1100, when the load wattage over this value, PAN08 will send Watt Meter Report command to the node of correspond Group. Default value=1100W5-4 Threshold of KWh for Load CautionThis is a warning when the KWh of load over the preset threshold value, If  the setting value is 10000, when the Accumulated Power Consumption of Relay1 or Relay2 over this value, PAN08 will send KWh Meter Report command to the node of correspond Guoup, minimum value is 1KWh and default value is 10000 kWh6. Command ClassesThe Switch supports Command Classes including…* COMMAND_CLASS_SWITCH_BINARY* COMMAND_CLASS_BASIC* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2* COMMAND_CLASS_VERSION* COMMAND_CLASS_ASSOCIATION* COMMAND_CLASS_METER_V3* COMMAND_CLASS_CONFIGURATION* COMMAND_CLASS_SWITCH_MULTILEVEL_V3* COMMAND_CLASS_ALARMTroubleshooting                 Symptom Cause of Failure Recommendation11
The PAN08 not working and LED off1. The PAN08 is not connect to the Main power2. The PAN08 break down1. Check power connections2. Don’t open up the PAN08 and send it for repair.The shutter move direction is reverseWrong connection of NC and NO to the motor Swap the NC NO connectionPAN08 LED light work fineBut can not control1. No association setting2. Same frequency interference1. Carry out association2. Wait for a while to re-trySpecificationOperating Voltage 100 ~240VACMaximum Load Resistive load 1100W/600W/550W(EU/US/TW) maxRange Minimum 30 m in door 100m outdoor  line of sightOperating Temperature 0°C ~ 40°CFrequency Range PAN08-1 868.42 (EU) / PAN08-2 908.42(USA/Canada) / PAN08-3 922.5/923.9/926.3MHz (Taiwan/JP)MHz** Specifications are subject to change and improvement without notice.                                                                                       FCC ID : RHHPAN08            Warning:1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm tothe environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.Company of License Holder:Philio Technology CorporationAddress of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City24257,Taiwan(R.O.C)FCC Interference StatementThis equipment has been tested and found to comply with the limits fora Class B digital device, pursuant to Part 15 of the FCC Rules. Theselimits are designed to provide reasonable protection against harmfulinterference in a residential installation. This equipment generates, usesand can radiate radio frequency energy and, if not installed and usedin accordance with the instructions, may cause harmful interference toradio communications. However, there is no guarantee thatinterference will not occur in a particular installation. If this equipmentdoes cause harmful interference to radio or television reception, which12
can be determined by turning the equipment off and on, the user isencouraged to try to correct the interference by one of the followingmeasures:• Reorient or relocate the receiving antenna.• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different fromthat to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician forhelp.This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, includinginterference that may cause undesired operation.FCC Caution: Any changes or modifications not expressly approved bythe party responsible for compliance could void the user's authority tooperate this equipment.This transmitter must not be co-located or operating in conjunctionwith any other antenna or transmitter.13