Philio Technology PAN08 In Wall Switch User Manual BH002 RF ON OFF CONTROLLER

Philio Technology Corporation In Wall Switch BH002 RF ON OFF CONTROLLER

Users Manual

Download: Philio Technology PAN08 In Wall Switch User Manual BH002  RF ON OFF CONTROLLER
Mirror Download [FCC.gov]Philio Technology PAN08 In Wall Switch User Manual BH002  RF ON OFF CONTROLLER
Document ID2023419
Application IDjUCbKjd2/LYGv0BhD4a2OA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize50.1kB (626300 bits)
Date Submitted2013-07-23 00:00:00
Date Available2013-07-25 00:00:00
Creation Date2013-05-30 16:03:35
Producing SoftwareLibreOffice 4.0
Document Lastmod0000-00-00 00:00:00
Document TitleBH002 RF ON/OFF CONTROLLER
Document CreatorWriter
Document Author: .

PAN08-1/-2/-3 Roller shutter controller
connected to this Roller Controller.
This in-wall Roller Shutter Controller is a transceiver which is a Z-WaveTM enabled
device and is fully compatible with any Z-WaveTM enabled network. Slim design let
the Controller can easily hide itself into the wall box and that will be good for the
house decoration.
The new smart relay calibration technology can reduce the inrush current caused by
the load and let the module work perfectly with many kind of Roller Shutter.
This in-wall Roller Shutter Controller is able to detect position of the Shutter by using
the patterned power measuring method, so it can be remote controlled not only fully
up or down , but also can be adjusted to ex. 30% or 50%. And when manual
controlled by push button, the controller also can memorize the position and send the
new shutter position to its controller (ex. IP-Gateway).
Adding to Z-WaveTM Network
In the front casing, there is an include button with LED indicator below which is used
to carry out inclusion, exclusion, reset or association. When first power is applied, its
LED flashes on and off alternately and repeatedly at 2-second intervals. It implies
that it has not been assigned a node ID and cannot work with Z-Wave enabled
devices.
Auto Inclusion
Fig 1. Assembling
The function of auto inclusion will be executed as long as the PAN08 does not have
Node ID and just connect the PAN08 to main power.
The in-wall Roller Shutter Controller is designed to switch rise/lower roller shutter
connected to its terminals using radio waves, controllers and a push button directly
Note: Auto inclusion timeout is 4 minute during which the node information of
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as
button again for 5 seconds until LED
shown in the table below, the execution of auto inclusion is free from pressing the
is off.
Include button on the PAN08.
Association
3.
IDs are excluded.
2-second on, 2-second off
1.
Have Z-Wave Controller entered
One press one flash
association mode.
The table below lists an operation summary of basic Z-Wave functions. Please refer
Or Pressing Include button three times
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
within 1.5 seconds will enter
Setup function, and to include/exclude/associate devices
association mode
2. There are 1 group (Group 1) for the
Function
Description
LED Indication
No node ID
The Z-Wave Controller does not allocate
2-second on, 2-second off
PAN08
※Including a node ID allocated by Z-Wave Controller means inclusion.
a node ID to the PAN08.
Inclusion
1.
Have Z-Wave Controller entered
Excluding a node
ID allocated by Z-Wave Controller means exclusion.
One press one flash
※Failed or success in including/excluding the node ID can be viewed from the Z-Wave
inclusion mode.
Controller.
2. Pressing Include button three times
within 1.5 seconds will enter
inclusion mode.
Exclusion
1.
Have Z-Wave Controller entered
LED Indication
One press one flash
To distinguish what mode the PAN08 is in, view from the LED for identification.
exclusion mode.
2.
Pressing Include button three times
within 1.5 seconds will enter
exclusion mode.
Reset
1.
Node ID has been excluded.
2-second on, 2-second off
Pressing Include button three times
One press one flash
LED Indication
Motor
No matter up or down, close or open, Led will flash every second
activate
while Motor activate.
No node ID
Under normal operation, when the PAN08 has not been allocated
a node ID, the LED flashes on and off alternately at 2-second
within 1.5 seconds will enter
intervals. By pressing S1 S2 or Include button, it will stop flashing
inclusion mode.
2.
State Type
temporarily. However, after disconnect and reconnect the PAN08,
Within 1 second, press Include
the LED will flash on and off alternately at 2-second intervals.
Overload
When overload state occurs, the PAN08 is disabled of which LED
flashes on and off alternately at 0.5 second intervals. Overload
state can be cleared by disconnect and reconnect the PAN08 to
the main power
Choosing a Suitable Location
1. Do not locate the PAN08 facing direct sunlight, humid or dusty place.
2. The suitable ambient temperature for the PAN08 is 0°C~40°C.
1. put the in wall PAN08 into a wall box and connect the AC power wire L,N to
3. Do not locate the PAN08 where exists combustible substances or any source of
PAN08 connector L, N.
heat, e.g. fires, radiators, boiler etc.
4. After putting it into use, the body of PAN08 will become a little bit hot of which
2. Connect the wall switch to the PAN08 as Fig1 .
phenomenon is normal.
Installation and operation
3. It is important to carry out a shutter calibration process before you control the
shutter to move. Press inclusion button over 3 seconds and release before the
6th second, the roller shutter controller will start the shutter calibration process.
The process is composed of three continue stages. The shutter move to the TOP
in first stage, and move to the BOTTOM in second stage, and move to the TOP
again in third stage. Then PAN08 will know the total range of UP and DOWN.
4. During the shutter calibration process, any emergencies happen you can press
and release the include button to stop the process
5. If user found the direction is reverse, this may because the wrong connection of
NC and NO to the motor, please change NC and NO connection and execute
calibration process again.
6. To manually switch up and down of the shutter, simply press S1 or S2 .
Basic Report Command:
[Command Class Basic, Basic Report, Value = 0x00 (BOTTOM)]
7. PAN08 built in meter function and can read the Watt , KWh, V(Voltage),
I(Current) , PF(Power Factor) of the load by using Z-Wave command class, user
[Command Class Basic, Basic Report, Value = 0x01~0x62 (Between BOT-
can set a threshold watt to get the warning caused by abnormal operation
TOM and TOP)]
[Command Class Basic, Basic Report, Value = 0xFE (UNKNOWN)]
8. PAN08 have overload protection function, and can help to prevent short circuit
[Command Class Basic, Basic Report, Value = 0x63/0xFF (TOP)]
caused by load.
1-2 BASIC_SET
Programming
PAN08 can only accept Basic Set Command which value is either (0x00)Bottom or
1. Basic Command Class
Top (0x63/0xFF),other value is not acceptable
The PAN08 will respond to BASIC and BINARY commands that are part of the
Z-Wave system.
1.1 BASIC_GET
[Command Class Basic, Basic Set, Value = 0x63 或 0xFF] control the
When PAN08 receive Basic Set Command,it will send Basic Report Command
shutter to the top (0xFF)。
to report the position of the curtain。When the report value is 0x00, that mean the
Shutter is bottom down, if the report value is 0xFF or 0x63 that mean the Shutter
is at the top, any other value between0x01~0x62 imply Shutter at 1%~99%
[Command Class Basic, Basic Set, Value = 0x00(0)] control the shutter to
position;But if report value is 0xFE means the position is unknown。
the bottom(0x00)。
2 Binary
Basic Get Command: [Command Class Basic, Basic Get]
Switch Command Class
2-1 BINARY_SWITCH_GET,
PAN08 can only accept Multilevel Switch Set Command which value is either
When PAN08 receive Binary Switch Get Command, it will send Binary Switch Report
(0x00)Bottom or Top (0x63 or 0xFF),other value is not acceptable。
Command to report the position of the curtain. When the report value is 0x00, that
mean the Shutter is bottom down, if the report value is 0xFF that mean the Shutter is
[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x63 or
at the top. But if report value is 0xFE means the position is unknown.
0xFF(255)] control the shutter to the top (0xFF)。
[Command Class Multilevel Switch, Multilevel Switch Set, Value = 0x00(0)] control
Binary Switch Get Command:
the shutter to the bottom(0x00)。
[Command Class Binary Switch, Binary Switch Get]
Binary Switch Report Command:
3-2 MULTILEVEL SWITCH GET:
[Command Class Binary Switch, Binary Switch Report, Value = 0x00(BOTTOM)]
When PAN08 receive Multilevel Switch Get Command, it will send Multilevel Switch
[Command Class Binary Switch, Binary Switch Report, Value = 0xFE(UNKNOWN)]
Report Command to report the position of the shutter. When the report value is 0x00,
[Command Class Binary Switch, Binary Switch Report, Value = 0xFF(TOP)]
that mean the shutter is bottom down, if the report value is 0xFF or 0x63 that mean
the shutter is at the top, any other value between0x01~0x62 imply shutter at
2-2 BINARY_SWITCH_SET
1%~99% position;But if report value is 0xFE means the position is unknown.
PAN08 can only accept Binary Switch Set Command which value is either (0x00)
Bottom or Top (0xFF),other value is not acceptable。
Switch Multilevel Get Command:
[Command Class Multilevel Switch, Multilevel Switch Get]
[Command Class Binary Switch, Binary Switch Set, Value = 0xFF(255)]
Multilevel Switch Report Comman:
control the shutter to the top (0xFF)。But if the shutter is on the way down, this
command will stop the shutter。
[Command Class Multilevel Switch, Multilevel Switch Report,
[Command Class Binary Switch, Binary Switch Set, Value = 0x00(0)]
Value = 0x00(BOTTOM)]
control the shutter to the bottom(0x00)。But if the shutter is on the way up, this command will stop the shutter。
[Command Class Multilevel Switch, Multilevel Switch Report,
Value = 0x01~0x62(Between BOTTOM and TOP)]
3. Multilevel Switch Command Class (Version 3):
[Command Class Multilevel Switch, Multilevel Switch Report,
3-1 MULTILEVEL SWITCH SET:
Example 1:If user want shutter move up , and the distance is 60% of total
Value = 0xFE(UNKNOWN)]
range(assume the now Step_Size= 50)
[Command Class Multilevel Switch, Multilevel Switch Report,
Command Class Multilevel Switch
Value = 0x63/0xFF(TOP)]
Multilevel Switch Start Level Change
3-3 MULTILEVEL SWITCH START LEVEL CHANGE:
Up/Down = 0x00
(UP = 0x00)
This is the command which user can move the shutter to the particular position ex. 60% of total range
[Command Class Multilevel Switch, Multilevel Switch Start Level Change,
Inc/Dec = 0x00
(Increment = 0x00:Step_Size = 50+10 = 60)
Step_Size = 10
This value represent how many the new
step_size want to increase or decrease
Up/Down Value , Inc/Dec Value, Step Size Value]。
3-3.1 Up/Down Bit :
Example 2: If user want shutter move down , and the distance is 50% of total
If Up/Down Bit=0x00 Shutter move up;
range(assume the now Step_Size= 50)
If Up/Down Bit=0x01 Shutter move down;
Command Class Multilevel Switch
If Up/Down Bit=0x03 no move
Multilevel Switch Start Level Change
3-3.2 Inc/Dec Bit:
Up/Down = 0x01
If Inc/Dec Bit=0x00 means New Step_Size = Now Step_Size + Step_Size ;
Inc/Dec = 0x03
If Inc/Dec Bit=0x01 means New Step_Size = Now Step_Size - Step_Size ;
(Down = 0x01)
(No Inc/Dec = 0x03:not change Step_Size
value,Step_Size = 50)
If Inc/Dec Bit=0x03 means New Step_Size = Now Step_Size
Step_Size = 0
This value represent how many the new
3-3.3 Step_Size:
step_size want to increase or decrease,
Range from 0x00~0x63 or 0xFF, default value=50, and the meaning of 0x63 and
when Inc/Dec = 0x03 please set this value to
0xFF is 100% of total range. If the Now Step_Size + Step_Size >100, the new
0)
Step_Size will stay at 100 , if the Now Step_Size - Step_Size <0 , the New
Step_Size will stay at 0
Example 3:If User not go to change shutter position but only change
Multilevel Switch Report:
Step_Size to 40%( assume the now Step_Size= 50)
Ex. Report position at 30%
Command Class Multilevel Switch
[Command Class Multilevel Switch, Multilevel Switch Report,Value = 30(%)]
Multilevel Switch Start Level Change
Up/Down = 0x03
Inc/Dec = 0x01
4-2 Meter Command Class:
The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated
(No Up/Down motion = 0x03)
power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I )
(Decrement = 0x01:Step_Size = 50–10 =
(5) load power factor (PF)
40)
Step_Size = 10
to Z-Wave Controller after receive the Meter Get
Command from Z-Wave Controller.
This value represent how many the new
step_size want to increase or decrease
When the power consumption of load vary over 5%, it will send Meter report to the
nodes of Group as well
ATT.1. Ignore_Start_Level、Start_Level、Dimming_Duration can not be used
4-2.1 Instant Power Consumption (Watt) of Switch
2. PAN08 can not control the speed of motor。
When receiving Meter Get Command, it will report Meter Report Command to the
3-3.4 MULTILEVEL SWITCH STOP LEVEL CHANGE:
node asked.
When receive Multilevel Switch Stop Level change Command PAN08 will stop the
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
motor。
Z-wave’s Groups introduction (Association Command Class Version 1 )
Meter Report Command: [Command Class Meter,Meter Report,scale(bit
There is only one group called Group1,there is only one node for Group1 which
2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter
support MULTILEVEL_SWITCH_REPORT、METER_REPORT_COMMAND_V3、
Value 1,Meter Value 2,Meter Value 3,Meter Value 4]
ALARM_REPORT。
4-1 Report the shutter position :
Rate Type = 0x01
Every time when user press S1 or S2 and let shutter to move, PAN08 will report the
Meter Type = 0x01
position status to controller, and at the moving process when change over 10%
Precision = 1
PAN08 will send Multilevel Switch Report to Group 1 also.
Scale = 0x02(W)
Size = 4 Bytes (Meter Value)
Meter Value 1 = (W) MSB
Meter Value 2 = (W)
Size = 4 bytes (Meter Value)
Meter Value 3 = (W)
Meter Value 1 = (KWh) MSB
Meter Value 4 = (W)LSB
Meter Value 2 = (KWh)
Meter Value 3 = (KWh)
Example:
Meter Value 4 = (KWh) LSB
Meter Value 1 = 0x00 (W)
Meter Value 2 = 0x00 (W)
Example:
Meter Value 3 = 0x03 (W)
Scale = 0x00 (KWh)
Meter Value 4 = 0xEA (W)
Precision = 2
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
Size = 4 Bytes (KW/h)
Meter Value 1 = 0x00(KWh)
4-2.2 Accumulated Power Consumption (KW/h)
Meter Value 2 = 0x01(KWh)
When receiving Meter Get Command, it will report Meter Report Command to
Meter Value 3 = 0x38(KWh)
the node asked.
Meter Value 4 = 0xA3(KWh)
Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value
Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00
3*256) + (Meter Value 4) = 800.35 (KW/h)
KW/h)]
Meter Report Command: [Command Class Meter,Meter
Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit
1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value
4]
4-2.3 AC load Voltage (V)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]
Rate Type = 0x01
Meter Type = 0x01
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]
Precision = 2
Scale = 0x00 (KWh)
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]
Rate Type = 0x01
Meter Type = 0x01
Precision = 1
Scale = 0x04(V)
Size = 2 Bytes (Meter Value)
Rate Type = 0x01
Meter Value 1 = High Byte (V)
Meter Type = 0x01
Meter Value 2 = Low Byte (V)
Precision = 2
Scale = 0x05(I)
Example:
Size = 2 Bytes (Meter Value)
Scale = 0x04 (V)
Meter Value 1 = High Byte (I)
Precision = 1
Meter Value 2 = Low Byte (I)
Size = 2 (2 Bytes of V)
Meter Value 1 = 0x09(V)
Example:
Meter Value 2 = 0x01(V)
Scale = 0x05 (I)
AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)
Precision = 2
Size = 2 (2 Bytes of I)
4-2.4 AC load current ( I )
Meter Value 1 = 0x01(I)
When receiving Meter Get Command, it will report Meter Report Command to the
Meter Value 2 = 0x21(I)
node asked.
AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)
4-2.5 load power factor (PF)
When receiving Meter Get Command, it will report Meter Report Command to the
node asked.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]
4-3 Alarm Report Command:
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1]
When PAN08 detect Overload,it will send Alarm_Report to Group1,Alarm
Level=0xFF。When receive Alarm_Get command and the PAN08 not in overload status , it will send Alarm_Report,Alarm Level=0x00。
Rate Type = 0x01
4-3.1 Alarm Report:
Meter Type = 0x01
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0xFF
Precision = 2
(Overload)]
Scale = 0x06(PF)
Size = 1 Bytes
[Command_Class_Alarm, Alarm_Report, Alarm Type = 0x08, Alarm Level = 0x00
Meter Value 1
(Normal)]
Example:
Scale = 0x06 (PF)
Precision = 2
Size = 1 (1 Byte of PF)
Meter Value 1 = 0x63(PF)
Load power factor (PF) = Meter Value 1 = 0.99
Z-Wave’s Configuration
Configuration
Function
Parameter
Size
Value
Unit
Default
Description
0x01-
5s
720
5*720s=3600s=1
(Byte)
Watt
4-2.6 reset Accumulated Power Consumption (KWh)
Meter
This command is to reset the Accumulated Power Consumption (KWh) to 0
Report
0x7FFF
hour
Period
Meter Reset Command:
[Command Class Meter, Meter Reset]
KWH
Meter
10
0x010x7FFF
10min
6*10min= 1 hour
3
Report
This is a warning when the wattage of load over the preset threshold value, If the
Period
setting value is 1100, when the load wattage over this value, PAN08 will send Watt
Threshold
10-1100
1watt
Meter Report command to the node of correspond Group. Default value=1100W
1100
of Watt
5-4 Threshold of KWh for Load Caution
for Load
This is a warning when the KWh of load over the preset threshold value, If the
Caution
Threshold
setting value is 10000, when the Accumulated Power Consumption of Relay1 or
1-10000
1KWh
Relay2 over this value, PAN08 will send KWh Meter Report command to the node of
10000
correspond Guoup, minimum value is 1KWh and default value is 10000 kWh
of KWH
for Load
Caution
6. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_SWITCH_BINARY
5-1 Watt Meter Report Period:
* COMMAND_CLASS_BASIC
If the setting is configured for 1hour (set value =720), the PAN08 will report its
instant power consumption every 1 hour to the node of correspond Group. The
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
maximum interval to report its instant power consumption is 45 hours
* COMMAND_CLASS_VERSION
(5s*32767/3600=45hr). Default value is 1 hour
* COMMAND_CLASS_ASSOCIATION
* COMMAND_CLASS_METER_V3
* COMMAND_CLASS_CONFIGURATION
5-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the PAN08 will report its
* COMMAND_CLASS_SWITCH_MULTILEVEL_V3
Accumulated Power Consumption (KW/h) every 1 hour to the node of correspond
* COMMAND_CLASS_ALARM
Group. The maximum interval to report its Accumulated Power Consumption
(KW/h) is 227.55 days (10min*32767/1440=227.55 days). Default value=1 hour
Troubleshooting
5-3 Threshold of Watt for Load Caution
Symptom
11
Cause of Failure
Recommendation
The PAN08 not working
and LED off
1. The PAN08 is not
connect to the Main
power
1. Check power connections
Warning:
2. Don’t open up the PAN08 and
1.Plug out to disconnect from power supply; Do not plug in line.
send it for repair.
2. Do not exceed the max rating
2. The PAN08 break
Disposal
down
The shutter move direction Wrong connection of NC
is reverse
This marking indicates that this product should not be disposed with
Swap the NC NO connection
other household wastes throughout the EU. To prevent possible harm to
and NO to the motor
PAN08 LED light work fine 1. No association setting
2. Same frequency
But can not control
interference
1. Carry out association
2. Wait for a while to re-try
the environment or human health from uncontrolled waste disposal,
recycle it responsibly to promote the sustainable reuse of material
resources. To return your used device, please use the return and
Specification
collection systems or contact the retailer where the product was
purchased. They can take this product for environmental safe recycling.
Operating Voltage
100 ~240VAC
Company of License Holder:Philio Technology Corporation
Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City
24257,Taiwan(R.O.C)
Maximum Load
Resistive load 1100W/600W/550W(EU/US/TW) max
Range
Minimum 30 m in door 100m outdoor line of sight
FCC Interference Statement
Operating Temperature 0°C ~ 40°C
This equipment has been tested and found to comply with the limits for
Frequency Range
PAN08-1 868.42 (EU) / PAN08-2 908.42(USA/Canada) / PAN08-3
a Class B digital device, pursuant to Part 15 of the FCC Rules. These
922.5/923.9/926.3MHz (Taiwan/JP)MHz
limits are designed to provide reasonable protection against harmful
interference in a residential installation. This equipment generates, uses
and can radiate radio frequency energy and, if not installed and used
** Specifications are subject to change and improvement without notice.
in accordance with the instructions, may cause harmful interference to
radio communications. However, there is no guarantee that
FCC ID : RHHPAN08
interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which
12
can be determined by turning the equipment off and on, the user is
encouraged to try to correct the interference by one of the following
measures:
• Reorient or relocate the receiving antenna.
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from
that to which the receiver is connected.
• Consult the dealer or an experienced radio/TV technician for
help.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including
interference that may cause undesired operation.
FCC Caution: Any changes or modifications not expressly approved by
the party responsible for compliance could void the user's authority to
operate this equipment.
This transmitter must not be co-located or operating in conjunction
with any other antenna or transmitter.
13

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Page Count                      : 13
Language                        : zh-TW