Philio Technology PAN11 smart energy plug User Manual BH002 RF ON OFF CONTROLLER

Philio Technology Corporation smart energy plug BH002 RF ON OFF CONTROLLER

(PAN11-4) UserMan_20130730_V2

PAN11-4/-5  Smart energy plug in switchP       This   plug-in   ON/OFF   switch   PAN11   is   a   wireless   switch,   based   on   Z-Wavetechnology.   Z-WaveTM  enabled devices displaying the Z-WaveTM  logo can also beused   with   it   regardless   of   the   manufacturer,   and   can   also   be   used   in   othermanufacturer’s Z-WaveTM enabled networks. Remote On/Off control of the connectedload   is   possible   with   other   manufacturer’s   wireless   Controller.   Each   switch   isdesigned to act as a repeater.  Repeaters will re-transmit the RF signal to ensure thatthe   signal   is   received   by   its   intended   destination   by   routing   the   signal   aroundobstacles and radio dead spots. This   plug-in   ON/OFF   switch   is   able   to   detect   current   wattage   (5~1500W)   andoverload wattage (1550~1700W) of connected lights or appliances. When detectingoverload state, the Switch will be disabled and its On/Off button will be lockout ofwhich LED will flash quickly.  However, unplug and re-connect the switch will reset itsoverload condition to normal status.Adding to Z-WaveTM NetworkIn the front casing, there is an On/Off button with LED indicator which is used totoggle switch on and off or carry out inclusion, exclusion, reset or association. Whenfirst power is applied, its  LED flashes on and off alternately and repeatedly at 2-second intervals. It implies that it has not been assigned a node ID and cannot workwith Z-Wave enabled devices. Auto InclusionThe function of auto inclusion will be executed as long as the switch does not haveNode ID and just plug the switch into a wall outlet.Note: Auto inclusion timeout is 4 minute during which the node information of explorer frame will be emitted once every 5 seconds.  Unlike “inclusion” function as shown in the table below, the execution of auto inclusion is free from pressing the On/Off button on the Switch.The table below lists an operation summary of basic Z-Wave functions. Please refer to the instructions for your Z-WaveTM Certificated Primary Controller to access the Setup function, and to include/exclude/associate devices1
Function Description LED IndicationNo node ID The Z-Wave Controller does not allocatea node ID to the Switch.2-second on, 2-second offInclusion 1. Have Z-Wave Controller entered inclusion mode.Press On, for onPress Off, for off2.  Pressing On/Off button three times within 1.5 seconds will enter inclusion mode.Exclusion 1. Have Z-Wave Controller entered exclusion mode.Press On, for onPress Off, for off2. Pressing On/Off button three times within 1.5 seconds will enter exclusion mode.Node ID has been excluded. 2-second on, 2-second offReset 1. Pressing On/Off button three times within 1.5 seconds will enter inclusion mode.Press On, for onPress Off, for off2. Within 1 second, press On/Off button again for 5 seconds until LEDis off.3. IDs are excluded. 2-second on, 2-second offAssociation 1. Have Z-Wave Controller entered association mode.Or  Pressing On/Off button three times within 1.5 seconds will enter Press On, for onPress Off, for offassociation mode2.  There are only one group for the switch※Including a node ID allocated by Z-Wave Controller means inclusion.  Excluding a nodeID allocated by Z-Wave Controller means exclusion.※Failed or success in including/excluding the node ID can be viewed from the Z-Wave Controller. LED IndicationTo distinguish what mode the switch is in, view from the LED for identification.State Type LED IndicationNormal Under normal operation, toggle On/Off button between On and Off. When pressing On, LED lights up, whereas Off, LED is off.No node ID Under normal operation, when the Switch has not been allocated a node ID, the LED flashes on and off alternately at 2-second intervals. By pressing On/Off button, it will stop flashing temporarily. However, after unplugging and reconnecting the Switch, the LED will flash on and off alternately at 2-second intervals.Overload When overload state occurs, the Switch is disabled of which LED flashes on and off alternately at 0.5 second intervals. Overload 2
state can be cleared by unplugging and reconnecting the Switch tothe wall outlet.Choosing a Suitable Location1. Do not locate the Switch facing direct sunlight, humid or dusty place.2. The suitable ambient temperature for the Switch is 0°C~40°C.3. Do not locate the Switch where exists combustible substances or any source of heat, e.g. fires, radiators, boiler etc.4. After putting it into use, the body of Switch will become a little bit hot of which phenomenon is normal.Installation1. Plug this On/Off Switch into a wall outlet near the load to be controlled.2. Plug the load into the Switch.  Make sure the load to be controlled cannot exceed1500 watts.3. Press the button or switch on the load to the ON position.4. To manually turn ON the Switch, press and release the On/Off button. The LEDwill turn ON, and the load plugged into the Switch will also turn ON.5. To manually turn OFF the Switch, simply press and release the On/Off button.The LED will turn OFF and the load plugged into the Switch will also turn OFF.Programming1.  Basic Command Class / Binary Switch Command ClassThe Switch will respond to BASIC and BINARY commands that are part of the Z-Wave system.1-1 BASIC_GET / BINARY_SWITCH_GET    Upon receipt of the following commands from a Z-Wave Controller, the Switch willreport its On/Off state to the Controller.Basic Get Command: [Command Class Basic, Basic Get]Basic Report Command:Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]Binary   Switch   Get   Command:[Command   Class   Switch   Binary,   SwitchBinary Get]Binary Switch Report Command:Report OFF:[Command Class Switch Binary, Switch Binary Report, Value=0(0x00)]Report ON:[Command Class Switch Binary, Switch Binary Report, Value = (255)0xFF]3
1-2 BASIC_SET / SWITCH_BINARY_SET        Upon  receipt   of  the following   commands   from a  Z-Wave  Controller,   the  loadattached to the Switch will turn on or off.[Command Class Basic, Basic Set, Value = (255)0xFF]: the load attachedto the Switch turns on.[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached tothe Switch turns off.[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:the load attached to the Switch turns on.[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: theload attached to the Switch turns off.2. Z-Wave’s Groups (Association Command Class Version 1)The Switch can be  set to  send reports to control associated  Z-Wave devices.   Itsupports one association group with one node support for Grouping 1. For grouping1, the Switch will report its latest status to Z-Wave Controller. Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT_COMMAND2-1 Auto report to Grouping 1 (Maximum Node 1)2-1-1 On/Off Event Report    When “on” or “off ” state has been changed, it will send Binary Switch Report to thenodes of Grouping 1.    Binary Switch ReportON:[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF]OFF:[Command Class Switch Binary, Switch Binary Report, Value =0(0x00)]2-1-2 Instant Power Consumption vary over 5% reportWhen the power consumption of load vary over 5%, it will send Meter report to thenodes of Grouping 1.2-2 Response to Meter Get Command   The Switch will report its (1) instant Power Consumption (Watt)  or (2) accumulatedpower consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I )(5) load power  factor (PF)    to Z-Wave  Controller   after receive  the   Meter  Get4Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4]
Command from Z-Wave Controller.2-2-1 Instant Power Consumption (Watt) of Switch    When receiving Meter Get Command, it will report Meter Report Command to thenode.Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)] Meter Report Command: [Command Class Meter,Meter Report,scale(bit2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4]Rate Type = 0x01Meter Type = 0x01Precision = 1Scale = 0x02(W)Size = 4 Bytes (Meter Value)Meter Value 1 = (W) MSBMeter Value 2 = (W)Meter Value 3 = (W)Meter Value 4 = (W)LSBExample:Meter Value 1 = 0x00 (W)Meter Value 2 = 0x00 (W)Meter Value 3 = 0x03 (W)Meter Value 4 = 0xEA (W)Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W2-2-2 Accumulated Power Consumption (KW/h)When receiving Meter Get Command, it will report Meter Report Command tothe node.Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 KW/h)]    Rate Type = 0x01     Meter Type = 0x01     Precision = 2     Scale = 0x00 (KWh)     Size = 4 bytes (Meter Value)     Meter Value 1 = (W) MSB     Meter Value 2 = (W)      Meter Value 3 = (W)     Meter Value 4 = (W) LSB5Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4]
     Example:     Scale = 0x00 (KWh)     Precision = 2     Size = 4 Bytes (KW/h)     Meter Value 1 = 0x00(W)     Meter Value 2 = 0x01(W)     Meter Value 3 = 0x38(W)     Meter Value 4 = 0xA3(W)     Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value3*256) + (Meter Value 4) = 800.35 (KW/h)2-2-3 Clearing accumulated power consumption   Meter Reset Command: [Command Class Meter, Meter Reset]2-2-4 AC load Voltage (V)    When receiving Meter Get Command, it will report Meter Report Command to thenode.  Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]  Rate Type = 0x01Meter Type = 0x01Precision = 1Scale = 0x04(V)Size = 2 Bytes (Meter Value)Meter Value 1 = High Byte (V)Meter Value 2 = Low Byte (V)Example:Scale = 0x04 (V)Precision = 1 Size = 2 (2 Bytes of  V)Meter Value 1 =  0x09(V)Meter Value 2 =  0x01(V)AC load Voltage =  (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)2-2-5 AC load current ( I )    When receiving Meter Get Command, it will report Meter Report Command to thenode.6Meter Report Command:[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]
  Rate Type = 0x01Meter Type = 0x01Precision = 2Scale = 0x05(I)Size = 2 Bytes (Meter Value)Meter Value 1 = High Byte (I)Meter Value 2 = Low Byte (I)Example:Scale = 0x05 (I)Precision = 2 Size = 2 (2 Bytes of I)Meter Value 1 =  0x01(I)Meter Value 2 =  0x21(I)AC load current =  (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)2-2-6 load power factor (PF)    When receiving Meter Get Command, it will report Meter Report Command to thenode.Rate Type = 0x01Meter Type = 0x01Precision = 2Scale = 0x06(PF)Size = 1 Bytes Meter Value 1 Example:Scale = 0x06 (PF)Precision = 2Size = 1 (1 Byte of  PF)Meter Value 1 =  0x63(PF)Load power factor (PF) = Meter Value 1 =0.993.  Z-Wave’s Configuration7Meter Report Command:[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1]
ConfigurationParameterFunction Size(Byte)Value Unit Default Description1 Watt Meter Report  Period2 0x01-0x7FFF5s 720 5*720s=3600s=1 hour2 KWH Meter Report  Period2 0x01-0x7FFF10min 6 6*10min= 1 hour33-1 Watt Meter Report Period:    If the setting is configured for 1hour (set value =720), the PAN11 will report itsinstant power consumption every 1 hour to Z-Wave Controller.   The maximuminterval   to   report   its   instant   power   consumption   is   45   hours(5s*32767/3600=45hr).3-2 KWH Meter Report Period:      If   the  setting   is  configured   for 1hour   (set  value  =6),   the  PAN11   will  report   itsAccumulated Power Consumption (KW/h) every 1 hour to Z-Wave Controller.  Themaximum interval to report its Accumulated Power Consumption (KW/h) is 227.55days (10min*32767/1440=227.55 days).4. Command ClassesThe Switch supports Command Classes including…* COMMAND_CLASS_SWITCH_BINARY* COMMAND_CLASS_BASIC* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2* COMMAND_CLASS_VERSION* COMMAND_CLASS_SWITCH_ALL* COMMAND_CLASS_ASSOCIATION_V1* COMMAND_CLASS_METER_V3* COMMAND_CLASS_CONFIGURATIONSocket TypeSince the socket type for each country in Europe varies, refer to the outline for each socket suited for each country as follows: Germany type PAN11-18
 France type PAN11-2 UK type PAN11-3                     PAN11-4 (USA/Canada)     PAN11-5 (Taiwan/JP) Note: Please make sure that the intensity of the plug of the electrical device must be 16A and have same head as the enclosed plug before inserting to the socket. Troubleshooting                 Symptom Cause of Failure RecommendationThe Switch not working andLED off1. The Switch is not plugged into the electrical outlet properly2. The Switch break down1. Check power connections2. Don’t open up the Switch and send it for repair.The Switch LED illuminating, but cannot control the ON/OFFSwitch of the load attachedCheck if the load plugged into the Switch has its own ON/OFF switchSet the ON/OFF switch of the load attached to ONThe Switch LED illuminating, but the 1. Not carry out association1. Carry out association2. Wait for a while to re-try9
Detector cannot controlthe Switch2. Same frequency interferenceLED keep flashing, but cannot controlOverload occurs Remove the load attached or checkmax. load cannot exceed 1550W~17000WSpecificationOperating Voltage         100~240VAC / 50-60HzMaximum Load 1500W for UL/TW/JPRange Minimum 30 m in door 70m outdoor  line of sightOperating Temperature 0°C ~ 40°CFrequency Range 908.42 MHz /UL; 922~926 MHz /TW/JP** Specifications are subject to change and improvement without notice.              FCC ID : RHHPAN11Warning:1.Plug out to disconnect from power supply; Do not plug in line. 2. Do not exceed the max rating Disposal This marking indicates that this product should not be disposed with other household wastes throughout the EU. To prevent possible harm tothe environment or human health from uncontrolled waste disposal, recycle it responsibly to promote the sustainable reuse of material resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling.Company of License Holder:Philio Technology CorporationAddress of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Taipei City 24257,Taiwan(R.O.C)  FCC Interference StatementThis equipment has been tested and found to comply with the limits for a Class B digital de-vice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference toradio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, whichcan be determined by turning the equipment off and on, the user is encouraged to try to cor-rect the interference by one of the following measures:• Reorient or relocate the receiving antenna.10
• Increase the separation between the equipment and receiver.• Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.• Consult the dealer or an experienced radio/TV technician for help.This device complies with Part 15 of the FCC Rules. Operation is subjectto the following two conditions:(1) This device may not cause harmful interference, and(2) This device must accept any interference received, including interference that may cause undesired operation.FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment.This transmitter must not be co-located or operating in conjunction with any other antenna ortransmitter.11