Philio Technology PAN11 smart energy plug User Manual BH002 RF ON OFF CONTROLLER
Philio Technology Corporation smart energy plug BH002 RF ON OFF CONTROLLER
(PAN11-4) UserMan_20130730_V2
overload condition to normal status. PAN11-4/-5 Smart energy plug in switch Adding to Z-WaveTM Network In the front casing, there is an On/Off button with LED indicator which is used to toggle switch on and off or carry out inclusion, exclusion, reset or association. When first power is applied, its LED flashes on and off alternately and repeatedly at 2second intervals. It implies that it has not been assigned a node ID and cannot work with Z-Wave enabled devices. Auto Inclusion The function of auto inclusion will be executed as long as the switch does not have Node ID and just plug the switch into a wall outlet. This plug-in ON/OFF switch PAN11 is a wireless switch, based on Z-Wave technology. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be used with it regardless of the manufacturer, and can also be used in other Note: Auto inclusion timeout is 4 minute during which the node information of manufacturer’s Z-WaveTM enabled networks. Remote On/Off control of the connected explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as load is possible with other manufacturer’s wireless Controller. Each switch is shown in the table below, the execution of auto inclusion is free from pressing the designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that On/Off button on the Switch. the signal is received by its intended destination by routing the signal around obstacles and radio dead spots. The table below lists an operation summary of basic Z-Wave functions. Please refer This plug-in ON/OFF switch is able to detect current wattage (5~1500W) and to the instructions for your Z-WaveTM Certificated Primary Controller to access the overload wattage (1550~1700W) of connected lights or appliances. When detecting Setup function, and to include/exclude/associate devices overload state, the Switch will be disabled and its On/Off button will be lockout of which LED will flash quickly. However, unplug and re-connect the switch will reset its Function Description LED Indication No node ID The Z-Wave Controller does not allocate 2-second on, 2-second off association mode a node ID to the Switch. Inclusion 1. Have Z-Wave Controller entered Press On, for on inclusion mode. Press Off, for off 2. There are only one group for the switch 2. Pressing On/Off button three times ※Including a node ID allocated by Z-Wave Controller means inclusion. within 1.5 seconds will enter ID allocated by Z-Wave Controller means exclusion. inclusion mode. Exclusion 1. 2. Reset 1. ※Failed or success in including/excluding the node ID can be viewed from the Z-Wave Have Z-Wave Controller entered Press On, for on exclusion mode. Press Off, for off Controller. Pressing On/Off button three times within 1.5 seconds will enter LED Indication exclusion mode. To distinguish what mode the switch is in, view from the LED for identification. Node ID has been excluded. 2-second on, 2-second off Pressing On/Off button three times Press On, for on State Type LED Indication within 1.5 seconds will enter Press Off, for off Normal Under normal operation, toggle On/Off button between On and inclusion mode. 2. Association Excluding a node Off. When pressing On, LED lights up, whereas Off, LED is off. Within 1 second, press On/Off No node ID Under normal operation, when the Switch has not been allocated button again for 5 seconds until LED a node ID, the LED flashes on and off alternately at 2-second is off. intervals. By pressing On/Off button, it will stop flashing 3. IDs are excluded. 2-second on, 2-second off temporarily. However, after unplugging and reconnecting the 1. Have Z-Wave Controller entered Press On, for on Switch, the LED will flash on and off alternately at 2-second association mode. Press Off, for off intervals. Overload Or Pressing On/Off button three times When overload state occurs, the Switch is disabled of which LED flashes on and off alternately at 0.5 second intervals. Overload within 1.5 seconds will enter The LED will turn OFF and the load plugged into the Switch will also turn OFF. state can be cleared by unplugging and reconnecting the Switch to the wall outlet. Choosing a Suitable Location Programming 1. Do not locate the Switch facing direct sunlight, humid or dusty place. 1. Basic Command Class / Binary Switch Command Class 2. The suitable ambient temperature for the Switch is 0°C~40°C. The Switch will respond to BASIC and BINARY commands that are part of the Z- 3. Do not locate the Switch where exists combustible substances or any source of Wave system. heat, e.g. fires, radiators, boiler etc. 1-1 BASIC_GET / BINARY_SWITCH_GET 4. After putting it into use, the body of Switch will become a little bit hot of which Upon receipt of the following commands from a Z-Wave Controller, the Switch will phenomenon is normal. report its On/Off state to the Controller. Installation Basic Get Command: [Command Class Basic, Basic Get] 1. Plug this On/Off Switch into a wall outlet near the load to be controlled. Basic Report Command: Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)] 2. Plug the load into the Switch. Make sure the load to be controlled cannot exceed Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF] 1500 watts. Binary Switch Get Command:[Command Class Switch Binary, Switch 3. Press the button or switch on the load to the ON position. Binary Get] Binary Switch Report Command: 4. To manually turn ON the Switch, press and release the On/Off button. The LED Report OFF:[Command Class Switch Binary, Switch Binary Report, Value will turn ON, and the load plugged into the Switch will also turn ON. =0(0x00)] Report ON:[Command Class Switch Binary, Switch Binary Report, Value 5. To manually turn OFF the Switch, simply press and release the On/Off button. = (255)0xFF] 2-1-1 On/Off Event Report 1-2 BASIC_SET / SWITCH_BINARY_SET When “on” or “off ” state has been changed, it will send Binary Switch Report to the Upon receipt of the following commands from a Z-Wave Controller, the load nodes of Grouping 1. attached to the Switch will turn on or off. Binary Switch Report [Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached to the Switch turns on. ON:[Command Class Switch Binary, Switch Binary Report, Value =(255)0xFF] [Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to the Switch turns off. OFF:[Command Class Switch Binary, Switch Binary Report, Value [Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]: =0(0x00)] the load attached to the Switch turns on. 2-1-2 Instant Power Consumption vary over 5% report [Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the load attached to the Switch turns off. When the power consumption of load vary over 5%, it will send Meter report to the nodes of Grouping 1. 2. Z-Wave’s Groups (Association Command Class Version 1) The Switch can be set to send reports to control associated Z-Wave devices. It Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4] supports one association group with one node support for Grouping 1. For grouping 1, the Switch will report its latest status to Z-Wave Controller. Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT_COMMAND 2-2 Response to Meter Get Command The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I ) 2-1 Auto report to Grouping 1 (Maximum Node 1) (5) load power factor (PF) to Z-Wave Controller after receive the Meter Get Command from Z-Wave Controller. Meter Value 2 = 0x00 (W) Meter Value 3 = 0x03 (W) Meter Value 4 = 0xEA (W) 2-2-1 Instant Power Consumption (Watt) of Switch Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W When receiving Meter Get Command, it will report Meter Report Command to the node. 2-2-2 Accumulated Power Consumption (KW/h) When receiving Meter Get Command, it will report Meter Report Command to the node. Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)] Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00 Meter Report Command: [Command Class Meter,Meter Report,scale(bit KW/h)] 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4] Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value 4] Rate Type = 0x01 Meter Type = 0x01 Precision = 1 Rate Type = 0x01 Scale = 0x02(W) Size = 4 Bytes (Meter Value) Meter Type = 0x01 Meter Value 1 = (W) MSB Precision = 2 Meter Value 2 = (W) Scale = 0x00 (KWh) Meter Value 3 = (W) Size = 4 bytes (Meter Value) Meter Value 4 = (W)LSB Meter Value 1 = (W) MSB Meter Value 2 = (W) Example: Meter Value 3 = (W) Meter Value 1 = 0x00 (W) Meter Value 4 = (W) LSB Example: Scale = 0x00 (KWh) Precision = 2 Size = 4 Bytes (KW/h) Meter Value 1 = 0x00(W) Rate Type = 0x01 Meter Value 2 = 0x01(W) Meter Type = 0x01 Meter Value 3 = 0x38(W) Precision = 1 Meter Value 4 = 0xA3(W) Scale = 0x04(V) Size = 2 Bytes (Meter Value) Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value Meter Value 1 = High Byte (V) 3*256) + (Meter Value 4) = 800.35 (KW/h) Meter Value 2 = Low Byte (V) 2-2-3 Clearing accumulated power consumption Example: Scale = 0x04 (V) Precision = 1 Meter Reset Command: [Command Class Meter, Meter Reset] Size = 2 (2 Bytes of V) Meter Value 1 = 0x09(V) Meter Value 2 = 0x01(V) 2-2-4 AC load Voltage (V) AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V) When receiving Meter Get Command, it will report Meter Report Command to the node. 2-2-5 AC load current ( I ) When receiving Meter Get Command, it will report Meter Report Command to the Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)] node. Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2] Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)] node. Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)] Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2] Meter Report Command: [Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1] Rate Type = 0x01 Meter Type = 0x01 Precision = 2 Rate Type = 0x01 Scale = 0x05(I) Meter Type = 0x01 Size = 2 Bytes (Meter Value) Precision = 2 Meter Value 1 = High Byte (I) Scale = 0x06(PF) Meter Value 2 = Low Byte (I) Size = 1 Bytes Meter Value 1 Example: Scale = 0x05 (I) Example: Precision = 2 Scale = 0x06 (PF) Size = 2 (2 Bytes of I) Precision = 2 Meter Value 1 = 0x01(I) Size = 1 (1 Byte of PF) Meter Value 2 = 0x21(I) Meter Value 1 = 0x63(PF) AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A) Load power factor (PF) = Meter Value 1 =0.99 2-2-6 load power factor (PF) 3. Z-Wave’s Configuration When receiving Meter Get Command, it will report Meter Report Command to the Configuration Function Size Parameter Value Unit Default * COMMAND_CLASS_BASIC Description * COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2 (Byte) Watt Meter Report Period KWH Meter 5s 720 * COMMAND_CLASS_VERSION 5*720s=3600s=1 hour * COMMAND_CLASS_SWITCH_ALL 0x7FFF Report Period 0x01- 0x01- 10min * COMMAND_CLASS_ASSOCIATION_V1 6*10min= 1 hour * COMMAND_CLASS_METER_V3 0x7FFF * COMMAND_CLASS_CONFIGURATION Socket Type Since the socket type for each country in Europe varies, refer to the outline for each 3-1 Watt Meter Report Period: socket suited for each country as follows: If the setting is configured for 1hour (set value =720), the PAN11 will report its instant power consumption every 1 hour to Z-Wave Controller. The maximum interval to report its instant power consumption is 45 hours (5s*32767/3600=45hr). 3-2 KWH Meter Report Period: If the setting is configured for 1hour (set value =6), the PAN11 will report its Accumulated Power Consumption (KW/h) every 1 hour to Z-Wave Controller. The maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55 days (10min*32767/1440=227.55 days). Germany type PAN11-1 4. Command Classes The Switch supports Command Classes including… * COMMAND_CLASS_SWITCH_BINARY PAN11-4 (USA/Canada) PAN11-5 (Taiwan/JP) France type PAN11-2 Note: Please make sure that the intensity of the plug of the electrical device must be 16A and have same head as the enclosed plug before inserting to the socket. Troubleshooting Symptom Cause of Failure Recommendation The Switch not working and 1. The Switch is not 1. Check power connections LED off 2. Don’t open up the Switch and plugged into the electrical outlet send it for repair. properly 2. The Switch break down UK type PAN11-3 The Switch LED Check if the load plugged Set the ON/OFF switch of the load illuminating, but cannot into the Switch has its control the ON/OFF own ON/OFF switch attached to ON Switch of the load attached The Switch LED illuminating, but the 1. Not carry out association 1. Carry out association 2. Wait for a while to re-try Detector cannot control 2. Same frequency the Switch This marking indicates that this product should not be disposed with interference LED keep flashing, but Overload occurs cannot control other household wastes throughout the EU. To prevent possible harm to Remove the load attached or check the environment or human health from uncontrolled waste disposal, max. load cannot exceed recycle it responsibly to promote the sustainable reuse of material 1550W~17000W resources. To return your used device, please use the return and collection systems or contact the retailer where the product was purchased. They can take this product for environmental safe recycling. Specification Operating Voltage 100~240VAC / 50-60Hz Company of License Holder:Philio Technology Corporation Maximum Load 1500W for UL/TW/JP Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New Range Minimum 30 m in door 70m outdoor line of sight Taipei City 24257,Taiwan(R.O.C) Operating Temperature 0°C ~ 40°C Frequency Range 908.42 MHz /UL; 922~926 MHz /TW/JP FCC Interference Statement ** Specifications are subject to change and improvement without notice. This equipment has been tested and found to comply with the limits for a Class B digital de- FCC ID : RHHPAN11 vice, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to Warning: radio communications. 1.Plug out to disconnect from power supply; Do not plug in line. However, there is no guarantee that interference will not occur in a particular installation. 2. Do not exceed the max rating If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to cor- Disposal rect the interference by one of the following measures: • Reorient or relocate the receiving antenna. 10 • Increase the separation between the equipment and receiver. • Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. • Consult the dealer or an experienced radio/TV technician for help. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. FCC Caution: Any changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate this equipment. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. 11
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No Author : . Create Date : 2013:07:29 13:20:16+08:00 Modify Date : 2013:07:30 13:56:41+08:00 Language : zh-TW XMP Toolkit : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00 Format : application/pdf Creator : . Title : BH002 RF ON/OFF CONTROLLER Creator Tool : Writer Metadata Date : 2013:07:30 13:56:41+08:00 Producer : LibreOffice 4.0 Document ID : uuid:fc4477f6-0d4b-44dd-9333-3342c6f8939b Instance ID : uuid:3a9e2de8-219e-485a-b593-808bd282775d Page Count : 11EXIF Metadata provided by EXIF.tools