Philio Technology PAN11 smart energy plug User Manual BH002 RF ON OFF CONTROLLER

Philio Technology Corporation smart energy plug BH002 RF ON OFF CONTROLLER

(PAN11-4) UserMan_20130730_V2

Download: Philio Technology PAN11 smart energy plug User Manual BH002  RF ON OFF CONTROLLER
Mirror Download [FCC.gov]Philio Technology PAN11 smart energy plug User Manual BH002  RF ON OFF CONTROLLER
Document ID2028286
Application IDrGRHM4UYDyM2u8OgI1Ck6w==
Document Description(PAN11-4) UserMan_20130730_V2
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize31.86kB (398236 bits)
Date Submitted2013-07-30 00:00:00
Date Available2013-07-31 00:00:00
Creation Date2013-07-29 13:20:16
Producing SoftwareLibreOffice 4.0
Document Lastmod2013-07-30 13:56:41
Document TitleBH002 RF ON/OFF CONTROLLER
Document CreatorWriter
Document Author: .

overload condition to normal status.
PAN11-4/-5 Smart energy plug in switch
Adding to Z-WaveTM Network
In the front casing, there is an On/Off button with LED indicator which is used to
toggle switch on and off or carry out inclusion, exclusion, reset or association. When
first power is applied, its LED flashes on and off alternately and repeatedly at 2second intervals. It implies that it has not been assigned a node ID and cannot work
with Z-Wave enabled devices.
Auto Inclusion
The function of auto inclusion will be executed as long as the switch does not have
Node ID and just plug the switch into a wall outlet.
This plug-in ON/OFF switch PAN11 is a wireless switch, based on Z-Wave
technology. Z-WaveTM enabled devices displaying the Z-WaveTM logo can also be
used with it regardless of the manufacturer, and can also be used in other
Note: Auto inclusion timeout is 4 minute during which the node information of
manufacturer’s Z-WaveTM enabled networks. Remote On/Off control of the connected
explorer frame will be emitted once every 5 seconds. Unlike “inclusion” function as
load is possible with other manufacturer’s wireless Controller. Each switch is
shown in the table below, the execution of auto inclusion is free from pressing the
designed to act as a repeater. Repeaters will re-transmit the RF signal to ensure that
On/Off button on the Switch.
the signal is received by its intended destination by routing the signal around
obstacles and radio dead spots.
The table below lists an operation summary of basic Z-Wave functions. Please refer
This plug-in ON/OFF switch is able to detect current wattage (5~1500W) and
to the instructions for your Z-WaveTM Certificated Primary Controller to access the
overload wattage (1550~1700W) of connected lights or appliances. When detecting
Setup function, and to include/exclude/associate devices
overload state, the Switch will be disabled and its On/Off button will be lockout of
which LED will flash quickly. However, unplug and re-connect the switch will reset its
Function
Description
LED Indication
No node ID
The Z-Wave Controller does not allocate
2-second on, 2-second off
association mode
a node ID to the Switch.
Inclusion
1.
Have Z-Wave Controller entered
Press On, for on
inclusion mode.
Press Off, for off
2. There are only one group for the
switch
2. Pressing On/Off button three times
※Including a node ID allocated by Z-Wave Controller means inclusion.
within 1.5 seconds will enter
ID allocated by Z-Wave Controller means exclusion.
inclusion mode.
Exclusion
1.
2.
Reset
1.
※Failed or success in including/excluding the node ID can be viewed from the Z-Wave
Have Z-Wave Controller entered
Press On, for on
exclusion mode.
Press Off, for off
Controller.
Pressing On/Off button three times
within 1.5 seconds will enter
LED Indication
exclusion mode.
To distinguish what mode the switch is in, view from the LED for identification.
Node ID has been excluded.
2-second on, 2-second off
Pressing On/Off button three times
Press On, for on
State Type
LED Indication
within 1.5 seconds will enter
Press Off, for off
Normal
Under normal operation, toggle On/Off button between On and
inclusion mode.
2.
Association
Excluding a node
Off. When pressing On, LED lights up, whereas Off, LED is off.
Within 1 second, press On/Off
No node ID
Under normal operation, when the Switch has not been allocated
button again for 5 seconds until LED
a node ID, the LED flashes on and off alternately at 2-second
is off.
intervals. By pressing On/Off button, it will stop flashing
3.
IDs are excluded.
2-second on, 2-second off
temporarily. However, after unplugging and reconnecting the
1.
Have Z-Wave Controller entered
Press On, for on
Switch, the LED will flash on and off alternately at 2-second
association mode.
Press Off, for off
intervals.
Overload
Or Pressing On/Off button three times
When overload state occurs, the Switch is disabled of which LED
flashes on and off alternately at 0.5 second intervals. Overload
within 1.5 seconds will enter
The LED will turn OFF and the load plugged into the Switch will also turn OFF.
state can be cleared by unplugging and reconnecting the Switch to
the wall outlet.
Choosing a Suitable Location
Programming
1. Do not locate the Switch facing direct sunlight, humid or dusty place.
1. Basic Command Class / Binary Switch Command Class
2. The suitable ambient temperature for the Switch is 0°C~40°C.
The Switch will respond to BASIC and BINARY commands that are part of the Z-
3. Do not locate the Switch where exists combustible substances or any source of
Wave system.
heat, e.g. fires, radiators, boiler etc.
1-1 BASIC_GET / BINARY_SWITCH_GET
4. After putting it into use, the body of Switch will become a little bit hot of which
Upon receipt of the following commands from a Z-Wave Controller, the Switch will
phenomenon is normal.
report its On/Off state to the Controller.
Installation
Basic Get Command: [Command Class Basic, Basic Get]
1. Plug this On/Off Switch into a wall outlet near the load to be controlled.
Basic Report Command:
Report OFF: [Command Class Basic, Basic Report, Value = 0(0x00)]
2. Plug the load into the Switch. Make sure the load to be controlled cannot exceed
Report ON:[Command Class Basic, Basic Report, Value = (255)0xFF]
1500 watts.
Binary Switch Get Command:[Command Class Switch Binary, Switch
3. Press the button or switch on the load to the ON position.
Binary Get]
Binary Switch Report Command:
4. To manually turn ON the Switch, press and release the On/Off button. The LED
Report OFF:[Command Class Switch Binary, Switch Binary Report, Value
will turn ON, and the load plugged into the Switch will also turn ON.
=0(0x00)]
Report ON:[Command Class Switch Binary, Switch Binary Report, Value
5. To manually turn OFF the Switch, simply press and release the On/Off button.
= (255)0xFF]
2-1-1 On/Off Event Report
1-2 BASIC_SET / SWITCH_BINARY_SET
When “on” or “off ” state has been changed, it will send Binary Switch Report to the
Upon receipt of the following commands from a Z-Wave Controller, the load
nodes of Grouping 1.
attached to the Switch will turn on or off.
Binary Switch Report
[Command Class Basic, Basic Set, Value = (255)0xFF]: the load attached
to the Switch turns on.
ON:[Command Class Switch Binary, Switch Binary Report, Value
=(255)0xFF]
[Command Class Basic, Basic Set, Value = 0(0x00)]: the load attached to
the Switch turns off.
OFF:[Command Class Switch Binary, Switch Binary Report, Value
[Command Class Switch Binary, Switch Binary Set, Value = (255)0xFF]:
=0(0x00)]
the load attached to the Switch turns on.
2-1-2 Instant Power Consumption vary over 5% report
[Command Class Switch Binary, Switch Binary Set, Value = 0(0x00)]: the
load attached to the Switch turns off.
When the power consumption of load vary over 5%, it will send Meter report to the
nodes of Grouping 1.
2. Z-Wave’s Groups (Association Command Class Version 1)
The Switch can be set to send reports to control associated Z-Wave devices. It
Meter Report Command: [Command Class Meter,Meter
Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit
1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value
4]
supports one association group with one node support for Grouping 1. For grouping
1, the Switch will report its latest status to Z-Wave Controller.
Grouping 1 includes, SWITCH_BINARY_REPORT, METER_REPORT_COMMAND
2-2 Response to Meter Get Command
The Switch will report its (1) instant Power Consumption (Watt) or (2) accumulated
power consumption(KWH) or (3) AC load Voltage (V) or (4) AC load current ( I )
2-1 Auto report to Grouping 1 (Maximum Node 1)
(5) load power factor (PF)
to Z-Wave Controller after receive the Meter Get
Command from Z-Wave Controller.
Meter Value 2 = 0x00 (W)
Meter Value 3 = 0x03 (W)
Meter Value 4 = 0xEA (W)
2-2-1 Instant Power Consumption (Watt) of Switch
Meter(W) = Meter Value 3 *256 + Meter Value 4 = 100.2W
When receiving Meter Get Command, it will report Meter Report Command to the
node.
2-2-2 Accumulated Power Consumption (KW/h)
When receiving Meter Get Command, it will report Meter Report Command to
the node.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x02(W)]
Meter Get Command: [Command Class Meter, Meter Get, Scale = 0x00
Meter Report Command: [Command Class Meter,Meter Report,scale(bit
KW/h)]
2) +Rate Type +Meter Type,Precision + Scale(bit 1,0)+ Size,Meter
Value 1,Meter Value 2,Meter Value 3,Meter Value 4]
Meter Report Command: [Command Class Meter,Meter
Report,scale(bit 2) +Rate Type +Meter Type,Precision + Scale(bit
1,0)+ Size,Meter Value 1,Meter Value 2,Meter Value 3,Meter Value
4]
Rate Type = 0x01
Meter Type = 0x01
Precision = 1
Rate Type = 0x01
Scale = 0x02(W)
Size = 4 Bytes (Meter Value)
Meter Type = 0x01
Meter Value 1 = (W) MSB
Precision = 2
Meter Value 2 = (W)
Scale = 0x00 (KWh)
Meter Value 3 = (W)
Size = 4 bytes (Meter Value)
Meter Value 4 = (W)LSB
Meter Value 1 = (W) MSB
Meter Value 2 = (W)
Example:
Meter Value 3 = (W)
Meter Value 1 = 0x00 (W)
Meter Value 4 = (W) LSB
Example:
Scale = 0x00 (KWh)
Precision = 2
Size = 4 Bytes (KW/h)
Meter Value 1 = 0x00(W)
Rate Type = 0x01
Meter Value 2 = 0x01(W)
Meter Type = 0x01
Meter Value 3 = 0x38(W)
Precision = 1
Meter Value 4 = 0xA3(W)
Scale = 0x04(V)
Size = 2 Bytes (Meter Value)
Accumulated power consumption (KW/h) = (Meter Value 2*65536) + (Meter Value
Meter Value 1 = High Byte (V)
3*256) + (Meter Value 4) = 800.35 (KW/h)
Meter Value 2 = Low Byte (V)
2-2-3 Clearing accumulated power consumption
Example:
Scale = 0x04 (V)
Precision = 1
Meter Reset Command: [Command Class Meter, Meter Reset]
Size = 2 (2 Bytes of V)
Meter Value 1 = 0x09(V)
Meter Value 2 = 0x01(V)
2-2-4 AC load Voltage (V)
AC load Voltage = (Meter Value 1*256) +(Meter Value 2)= 230.5 (V)
When receiving Meter Get Command, it will report Meter Report Command to the
node.
2-2-5 AC load current ( I )
When receiving Meter Get Command, it will report Meter Report Command to the
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x04(V)]
node.
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x05(I)]
node.
Meter Get Command: [Command Class Meter, Meter Get, Scale =0x06(PF)]
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1,Meter Value 2]
Meter Report Command:
[Command Class Meter,Meter Report,scale(bit 2) +Rate Type +Meter
Type,Precision + Scale(bit 1,0)+ Size,Meter Value 1]
Rate Type = 0x01
Meter Type = 0x01
Precision = 2
Rate Type = 0x01
Scale = 0x05(I)
Meter Type = 0x01
Size = 2 Bytes (Meter Value)
Precision = 2
Meter Value 1 = High Byte (I)
Scale = 0x06(PF)
Meter Value 2 = Low Byte (I)
Size = 1 Bytes
Meter Value 1
Example:
Scale = 0x05 (I)
Example:
Precision = 2
Scale = 0x06 (PF)
Size = 2 (2 Bytes of I)
Precision = 2
Meter Value 1 = 0x01(I)
Size = 1 (1 Byte of PF)
Meter Value 2 = 0x21(I)
Meter Value 1 = 0x63(PF)
AC load current = (Meter Value 1*256) +(Meter Value 2)= 2.89 (A)
Load power factor (PF) = Meter Value 1 =0.99
2-2-6 load power factor (PF)
3. Z-Wave’s Configuration
When receiving Meter Get Command, it will report Meter Report Command to the
Configuration
Function
Size
Parameter
Value
Unit
Default
* COMMAND_CLASS_BASIC
Description
* COMMAND_CLASS_MANUFACTURER_SPECIFIC_V2
(Byte)
Watt Meter
Report Period
KWH Meter
5s
720
* COMMAND_CLASS_VERSION
5*720s=3600s=1 hour
* COMMAND_CLASS_SWITCH_ALL
0x7FFF
Report Period
0x01-
0x01-
10min
* COMMAND_CLASS_ASSOCIATION_V1
6*10min= 1 hour
* COMMAND_CLASS_METER_V3
0x7FFF
* COMMAND_CLASS_CONFIGURATION
Socket Type
Since the socket type for each country in Europe varies, refer to the outline for each
3-1 Watt Meter Report Period:
socket suited for each country as follows:
If the setting is configured for 1hour (set value =720), the PAN11 will report its
instant power consumption every 1 hour to Z-Wave Controller. The maximum
interval
to
report
its
instant
power
consumption
is
45
hours
(5s*32767/3600=45hr).
3-2 KWH Meter Report Period:
If the setting is configured for 1hour (set value =6), the PAN11 will report its
Accumulated Power Consumption (KW/h) every 1 hour to Z-Wave Controller. The
maximum interval to report its Accumulated Power Consumption (KW/h) is 227.55
days (10min*32767/1440=227.55 days).
Germany type PAN11-1
4. Command Classes
The Switch supports Command Classes including…
* COMMAND_CLASS_SWITCH_BINARY
PAN11-4 (USA/Canada)
PAN11-5 (Taiwan/JP)
France type PAN11-2
Note: Please make sure that the intensity of the plug of the electrical device must be
16A and have same head as the enclosed plug before inserting to the socket.
Troubleshooting
Symptom
Cause of Failure
Recommendation
The Switch not working and 1. The Switch is not
1. Check power connections
LED off
2. Don’t open up the Switch and
plugged into the
electrical outlet
send it for repair.
properly
2. The Switch break
down
UK type PAN11-3
The Switch LED
Check if the load plugged Set the ON/OFF switch of the load
illuminating, but cannot
into the Switch has its
control the ON/OFF
own ON/OFF switch
attached to ON
Switch of the load attached
The Switch LED
illuminating, but the
1. Not carry out
association
1. Carry out association
2. Wait for a while to re-try
Detector cannot control
2. Same frequency
the Switch
This marking indicates that this product should not be disposed with
interference
LED keep flashing, but
Overload occurs
cannot control
other household wastes throughout the EU. To prevent possible harm to
Remove the load attached or check
the environment or human health from uncontrolled waste disposal,
max. load cannot exceed
recycle it responsibly to promote the sustainable reuse of material
1550W~17000W
resources. To return your used device, please use the return and
collection systems or contact the retailer where the product was
purchased. They can take this product for environmental safe recycling.
Specification
Operating Voltage
100~240VAC / 50-60Hz
Company of License Holder:Philio Technology Corporation
Maximum Load
1500W for UL/TW/JP
Address of License Holder:8F.,No.653-2,Zhongzheng Rd., Xinzhuang Dist., New
Range
Minimum 30 m in door 70m outdoor line of sight
Taipei City 24257,Taiwan(R.O.C)
Operating Temperature 0°C ~ 40°C
Frequency Range
908.42 MHz /UL; 922~926 MHz /TW/JP
FCC Interference Statement
** Specifications are subject to change and improvement without notice.
This equipment has been tested and found to comply with the limits for a Class B digital de-
FCC ID : RHHPAN11
vice, pursuant to Part 15 of the FCC Rules.
These limits are designed to provide reasonable protection against harmful interference in a
residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not installed
and used in accordance with the instructions, may cause harmful interference to
Warning:
radio communications.
1.Plug out to disconnect from power supply; Do not plug in line.
However, there is no guarantee that interference will not occur in a particular installation.
2. Do not exceed the max rating
If this equipment does cause harmful interference to radio or television reception, which
can be determined by turning the equipment off and on, the user is encouraged to try to cor-
Disposal
rect the interference by one of the following measures:
• Reorient or relocate the receiving antenna.
10
• Increase the separation between the equipment and receiver.
• Connect the equipment into an outlet on a circuit different from that to which the receiver is
connected.
• Consult the dealer or an experienced radio/TV technician for help.
This device complies with Part 15 of the FCC Rules. Operation is subject
to the following two conditions:
(1) This device may not cause harmful interference, and
(2) This device must accept any interference received, including interference that may cause
undesired operation.
FCC Caution: Any changes or modifications not expressly approved by the party responsible
for compliance could void the user's authority to operate this equipment.
This transmitter must not be co-located or operating in conjunction with any other antenna or
transmitter.
11

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Author                          : .
Create Date                     : 2013:07:29 13:20:16+08:00
Modify Date                     : 2013:07:30 13:56:41+08:00
Language                        : zh-TW
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Format                          : application/pdf
Creator                         : .
Title                           : BH002  RF ON/OFF CONTROLLER
Creator Tool                    : Writer
Metadata Date                   : 2013:07:30 13:56:41+08:00
Producer                        : LibreOffice 4.0
Document ID                     : uuid:fc4477f6-0d4b-44dd-9333-3342c6f8939b
Instance ID                     : uuid:3a9e2de8-219e-485a-b593-808bd282775d
Page Count                      : 11
EXIF Metadata provided by EXIF.tools
FCC ID Filing: RHHPAN11