Philips Consumer Lifestyle PR3841 Wireless interface for TENS device User Manual
Philips Consumer Lifestyle Wireless interface for TENS device
User Manual.pdf
PR3841 PR3841 ENGLISH 4 4 ENGLISH Table of contents Important Glossary Introduction Intended use Device description Benefits and risks Important safeguards How the device works Pre-set programs Signals on the device Preparing for use Using the device After use Assistance Troubleshooting Replacement Accessories Full Two-Year Warranty 45-Day Money-Back Guarantee Battery recycling Compliance information Specifications Explanation of symbols Electrode placement guide 13 14 18 19 20 27 30 30 32 32 33 34 35 36 38 41 48 Important Pay special attention to all warnings, precautions and contraindications in this user manual. Follow them strictly during use. Save the user manual for future reference. ENGLISH Glossary ----------- CE: Conformité Européenne CEC: California Energy Commission EC: European Commission EMS: electrical muscle stimulation EU: European Union FCC: Federal Communications Commission OTC: over the counter RF: radio frequency TENS: transcutaneous electrical nerve stimulation USB: universal serial bus Introduction Thank you for buying this product. If you want to benefit fully from the support that Philips offers, please register your product at www.philips.com/pain-relief/ register.The PulseRelief device is available without prescription.To get the best possible results with this device, we advise you to follow the instructions in this user manual. If you have questions or need extra information, go to www.philips.com/pain-relief or call toll-free 1-844-531-6861 (Monday - Saturday 9:00 AM - 9:00 PM EST, Sunday 9:00 AM – 6:00 PM EST, excluding Major Holidays). Intended use The OTC TENS/EMS stimulator PulseRelief is designed to be used for temporary relief of pain associated with sore and aching muscles in the shoulder, waist, back, neck, upper extremities (arm), and lower extremities (leg) due to strain from exercise or normal household workactivities. It should be applied to normal, healthy, dry and clean skin of adult patients. And is to be used for stimulate healthy muscles in order to improve and facilitate muscle performance. 6 ENGLISH Device description 10 10 On/off button Status indicator Detachable connector Micro-USB socket of device Battery indicator Adapter Socket for standard USB plug Standard USB plug Micro-USB plug Self-adhesive hydrogel electrodes Benefits and risks Benefits TENS programs can help relieve pain in muscles that are sore and aching due to exercise or normal household work. EMS programs make muscles contract. Muscle contraction may improve and facilitate muscle performance. ENGLISH Risks General risk TENS only treats symptoms. It reduces the feeling of pain, but it does not cure the cause of the pain. Pain may be a signal from your body that some part of your body is damaged and needs attention. Specific risks -- You may get skin irritation and burns under the electrodes applied to your skin. -- You may get a headache or other pain if you use the device near your eye, or on your head or face. -- You may feel faint or sick during or after use of the device. -- Some reddening of the skin under or around the electrodes may occur during and shortly after EMS treatment. Skin reddening usually disappears within two hours after treatment. If the skin continues to be red for more than a day, please consult your physician. -- You may experience muscle exhaustion or muscle soreness after extended use of the EMS programs on the same muscles (more than 30 minutes a session, up to 3 times a day). Stop using the device and consult your physician if you experience adverse reactions from the device. To ensure safe usage of the device, follow the instructions in this user manual. Read the contraindications, warnings and precautions sections before you use this device. If you are not sure if the device is suitable for you, consult your physician before using this device. 8 ENGLISH IMPORTANT SAFEGUARDS Contraindications Do not use this device with the following medical devices: -- Implanted electronic medical devices, such as pacemakers. This may cause electric shock, burns, or death. -- Electronic life support equipment, such as respirators. -- Electronic medical devices worn on the body, such as electrocardiographs. If you use this device together with other electronic medical devices, these devices may not work correctly. Warnings -- If you are in the care of a physician, consult your physician before you use this device. -- If you have had medical or physical treatment for your pain, consult your physician before you use this device. -- If your pain does not improve, becomes more than mild, or continues for more than five days, stop using the device and consult your physician. -- Consult your physician before you use this device. The device may cause lethal disturbances to the heart rhythm in susceptible individuals. -- Do not use the device if you have a cognitive impairment (e.g. dementia, Alzheimer’s disease). People who have a cognitive impairment may be unable to use the device according to the instructions and may become agitated by the treatment. -- Do not apply electrical muscle stimulation (EMS) over painful areas. If you have painful areas, consult your physician before you use the device. ENGLISH -- Do not use the device on children, as it has not been evaluated for pediatric use. -- Do not use the device on your neck. This could cause severe muscle spasms that may result in closure of your airway, breathing difficulties, or adverse effects on heart rhythm or blood pressure. -- Do not use the device across your chest. The device introduces electrical current. Using the device in your chest may cause rhythm disturbances to your heart, which could be lethal. -- Use the device only on normal, intact, clean, and healthy skin. ,, Do not use the device over open wounds or rashes, and over swollen, red, infected, or inflamed areas or skin eruptions (e.g., phlebitis, thrombophlebitis, varicose veins). -- Do not use the device over, or close to, cancerous lesions. -- Do not place the electrodes simultaneously on both legs, both arms, or on the soles of both feet.This may have adverse effects on your heart rhythm. -- Do not place the electrodes inside body cavities, e.g. the mouth. This may cause skin irritation, skin burns or electrical shocks. This device is not designed for internal application. -- Do not use the device in the presence of electronic monitoring equipment (e.g., cardiac monitors, ECG alarms). This equipment may not operate properly when the electrical stimulation device is in use. -- Do not use the device when in the bath or shower. -- Do not use the device while sleeping. 10 ENGLISH -- Do not use the device while driving, operating machinery, or during any activity in which electrical stimulation can put you at risk of injury. -- Do not modify the device or the electrodes. This could cause improper functioning. -- As the electrical performance characteristics of electrodes may affect the safety and effectiveness of electrical stimulation, take the following into account: 1 If the electrodes are too small or not correctly applied, this may result in discomfort or skin burn. 2 Contact the manufacturer of the device, if you do not know if the electrode can be used with the device. Precautions -- TENS is not effective for pain of central origin, including headache. -- TENS is not a substitute for pain medications and other pain management therapies. -- TENS devices have no curative value. -- TENS is a symptomatic treatment. It suppresses the sensation of pain that normally serves as a protective mechanism. -- As TENS treatment may not be effective for everyone, consult your physician or healthcare professional to find out if TENS will work in your case. -- The long-term effects of electrical stimulation are unknow -- Because the effects of stimulation on the brain are unknown, do not use the device on opposite sides of your head. -- Electrical stimulation or the electrical conductive gel may cause skin irritation or hypersensitivity. -- If you have suspected or diagnosed heart disease, follow the precautions from your physician. -- If you have suspected or diagnosed epilepsy, follow the precautions from your physician. ENGLISH 11 -- Use caution if you are likely to have internal bleeding, for instance, after injuries or fractures. -- If you had surgery recently, consult your physician before you use the device. Using the device may disrupt the healing process. -- Use caution when you use the device over areas of skin that lack normal sensation. -- The impact of using this device during pregnancy is unknown. It may be not safe. -- Use caution when you use the device over the uterus during pregnancy or menstruation. -- Keep this device out of the reach of children. -- Do not use the device or an electrode if it is damaged. Always check the device and the electrodes for damage before use. -- Replace the self-adhesive electrodes if they no longer stick firmly to your skin. -- Do not use plaster or tape to attach the electrodes to the skin. -- Make sure that the electrodes do not touch metal objects, such as belt buckles or necklaces. -- Use this device only with Philips self-adhesive hydrogel electrodes, and the Philips adapter and USB cord supplied with the device. -- Use burst TENS programs while sitting or lying. These programs can result in muscle contractions. -- Always end the treatment in the Philips Treatment App or press the on/off button on the device before you remove the device or the electrodes. If you do not end the treatment, you may get an unpleasant sensation in your fingers when you touch the magnets. This sensation is not harmful, but it can be unpleasant. 12 ENGLISH General recommendations -- Read this user manual carefully and always follow the treatment instructions. -- Do not use this device for any other purpose than what it is intended for. -- This device is designed for use by and on a single adult person. For hygienic reasons electrodes should not be shared. -- Do not use EMS stimulation to contract a muscle if contraction of the muscle may disrupt healing. For instance, muscle contraction may exacerbate the tear if a muscle or tendon is torn. After a recent surgical procedure, an acute trauma or a fracture, EMS stimulation may have an adverse effect on the healing process. Muscle contraction in case of tendinitis may also worsen symptoms. -- Do not use the device if you are connected to high-frequency surgical equipment. This may result in burns on the skin under the electrodes and may damage the device. -- Do not use the device within less than 39 inches (1 meter) from shortwave or microwave medical equipment. Close proximity to this equipment may cause unstable device output. -- Do not use the device if it is closer than 12 inches (30.5cm) to wireless communication equipment, such as wireless home network routers, cell phones, cordless phones and their base stations, and walkietalkies. The electromagnetic interference of this wireless communication equipment may prevent the device from operating properly. -- The device is not waterproof. Do not use the device in wet surroundings. ENGLISH 13 -- Although you can use the device indoors and outdoors, it does not withstand all weather conditions. -- The device does not withstand temperatures higher than 104°F (40°C) or lower than 41°F (5°C). -- The electrodes have a limited shelf life. Please check the packaging for the use-by date before use. Do not use electrodes whose use-by date has expired. -- Always use and store the electrodes according to the instructions. -- If the device does not function as described here, stop using it and call toll-free 1-844-531-6861 (Monday - Saturday 9:00 AM - 9:00 PM EST, Sunday 9:00 AM – 6:00 PM EST, excluding Major Holidays). SAVE THESE INSTRUCTIONS How the device works TENS TENS is a non-invasive pain relief method. Healthcare professionals, such as chiropractors, physicians and physiotherapists, often use this method.TENS relieves pain in a way similar to rubbing the pain away. By rubbing, you cause a different skin sensation to mask pain.The device generates electrical pulses. Selfadhesive electrodes are placed on the skin close to the area of pain. The device delivers pulses across the skin through these electrodes.This activates the underlying sensory nerves.You can choose 15 pre-set TENS programs with different pulse settings. In each program, you can adjust the intensity of the pulse. 14 ENGLISH EMS EMS is a method for muscle conditioning. It uses a device and electrodes placed on the skin. The electrodes are placed near the muscle to be stimulated. The device generates electrical pulses and passes these pulses across the surface of the skin to activate the underlying motor nerves. This makes the muscle contract. Contraction helps to condition the muscle. You can choose from 5 pre-set EMS programs. In each program, you can adjust the intensity of the pulse. Pre-set programs The device comes with 15 pre-set programs for TENS and 5 pre-set programs for EMS. The order of the programs in the list does not mean that certain programs are more suitable for specific conditions than others. As the effect of a treatment program may strongly differ from person to person, we advise you to try out different treatment programs to find out which one works best for you. Program overview Conventional TENS programs Conventional TENS programs deliver high-frequency stimulation.Their working mechanism is based on the Gate Control Theory.This theory states that stimulation blocks the transmission of pain signals. It is similar to rubbing away pain. Most people use conventional TENS for 30 minutes per session. You can use it as often and as long as it feels comfortable.You will notice the effect most clearly during use.The effect generally wears off rather quickly after use. Adjust the intensity so that you clearly feel the pulses.Treatment must not feel unpleasant or painful. ENGLISH 15 Name of Program description conventional TENS program Suggested treatment time Conventional May give you a continuous tingling stimulation No limit Thorough stimulus May give you a more thorough stimulating sensation No limit Pre-activity May give you a more local and soft stimulating sensation No limit Soft stimulus May give you a softer stimulating sensation, e.g. for sensitive body parts No limit Deep stimulus May give you a deeper stimulating sensation No limit Radiating pulse May give you a more radiating stimulation sensation No limit Burst TENS programs Burst TENS uses high-frequency stimulation that comes in trains of pulses. This triggers the release of endorphins, which are painkillers produced by the body. You can use burst TENS for 30 minutes several times a day. Adjust the intensity of the burst program so that you feel the pulses strongly. The sensation can be slightly unpleasant. Set the intensity to a level that causes visible muscle contractions in the treatment area. These contractions are not harmful. If you find them too uncomfortable, decrease the intensity, choose a different program, or move the electrodes to a different place. Use burst TENS programs while sitting or lying. Burst TENS can lead to muscle contraction in the treatment area. 16 ENGLISH Name of burst TENS program Program description Suggested treatment time Continuous burst May give you a pulsing burst stimulation to release endorphins in your body 30 min.* Slow kneading May give you a slower and massaging burst stimulation to release endorphins 30 min.* Mild kneading May give you a milder burst stimulation to release endorphins in your body 30 min.* Deep kneading May give you a more local and deeper burst stimulation to release endorphins in your body 30 min.* Diffuse burst May give you a more diffused burst stimulation to release endorphins in your body 30 min.* * optionally multiple times a day, can be changed in the app Frequency-modulated TENS programs Frequency-modulated TENS uses pulses that vary from high frequency to low frequency. In some cases, this program may be more comfortable or effective than the other programs. You can use frequencymodulated TENS for 30 minutes several times a day. ENGLISH 17 Name of freq. mod. TENS program Program description Suggested treatment time Mixed frequency May give you a flowing stimulation sensation 30 min.* Pulsing massage May give you a more pulsing stimulation sensation 30 min.* Deep massage May give you a slower and deeper flowing sensation 30 min.* Gentle massage May give you a mild flowing stimulation sensation 30 min.* * optionally multiple times a day, can be changed in the app Electrical muscle stimulation (EMS) programs EMS uses pulses to evoke muscle contraction. This may help to condition muscles. Use EMS only on healthy, uninjured muscles. Apply EMS programs while sitting or lying, as they result in muscle contraction. EMS may feel unusual to new users. We advise new users to start at a low intensity to get used to the sensation. EMS should always feel comfortable. Muscle contractions must not be tiring. If you apply EMS after exercising, use a lower setting to avoid muscle fatigue. 18 ENGLISH Name of EMS program Program description Suggested treatment time Muscle stimulation pulse May give you a nice soothing sensation 30 min.* Muscle stimulation flow May give you a comfortable tingling sensation 20 min.* Muscle stimulation wave May give you a mild contracting and relaxing sensation 30 min.* Muscle stimulation flux May give you an energizing muscle sensation 25 min.* Muscle stimulation bounce May give you a rhythmically relaxing sensation 20 min.* * optionally multiple times a day, can be changed in the app Signals on the device Battery indicator -- It is solid orange during charging and when the rechargeable battery is low. -- It is solid green when the device is connected to an electrical outlet. -- It is also solid green when the rechargeable battery is fully charged. Status indicator -- It flashes orange during treatment. -- It flashes green when the device is pairing. -- It is solid green when the device is in standby mode. ENGLISH 19 Preparing for use Charging the device You have to charge the device before you can use it. It takes about 5 hours to charge the device. When it is fully charged, you can use the device for about 8 hours. Note: If the device is not fully charged when you start using it, the battery may run out during the treatment. We advise you to always fully charge the device before use. Note:You cannot use the device during charging. 1 Unplug the cable for connecting the two units from the micro-USB socket of the device. 2 Insert the micro-USB plug of the adapter cable into the micro-USB socket of the device. 3 Insert the USB plug into the socket of the adapter and insert the adapter into an electrical outlet. Note: Insert the USB plug into a properly accessible electrical outlet so that you can remove it easily. ,, The battery indicator is solid orange during charging. When the battery is fully charged, the battery indicator turns solid green. 4 Remove the micro-USB plug from the micro-USB socket of the device. Note: Only use the USB socket to connect the adapter cable or the cable for connecting the two units. Do not use this socket for any other purpose. 20 ENGLISH 5 To reconnect the two device units, insert the connector of the cable for connecting the two device units into the micro-USB socket Installing and setting up the Treatment App You need the Philips Treatment app to operate the device. Please go to the Apple App Store or Google Play, search for the ‘Philips Treatment’ app and press install. Using the device Use this device for its intended household use as described in this user manual. Note: It is important to perform the steps in the order described in this chapter. Attaching the electrodes and the device 1 Make sure that the skin you want to place the electrodes on looks healthy and is free from wounds or rashes. For TENS: Do not place the electrodes on red or inflamed skin and skin with open wounds, cancerous lesions or rashes. For EMS: Only place the electrodes on healthy, uninjured muscles. 2 Clean the skin with a moist cloth and dry it thoroughly. The skin you want to place the electrodes on must be dry, clean and free from cream or lotion. ENGLISH 21 Note: Dirt, grease or particles left on the skin may lodge themselves in the hydrogel of the electrodes.This has an adverse effect on the adhesive power of the electrodes. 3 Take the electrodes from the plastic bag and check them for damage and signs of wear. Caution: Do not use electrodes whose use-by date has expired. The use-by date is shown on the resealable plastic bag. Note: Replace the electrodes when they are damaged or dirty, when they have lost their adhesive power or when stimulation becomes uncomfortable, i.e. when you experience an unpleasant stinging or biting sensation. 4 Pull the electrode off the liner and place it on the skin at the place you want to treat. See section ‘Electrode placement’ and the placement guide. 5 Place the second electrode on the body part you want to treat. Note: Always place the electrodes on the skin before you connect the device. Note: Do not place the electrodes on top of each other or so close to each other that they touch each other. 22 ENGLISH 6 Attach the device to the electrodes. The device units have magnets in the center to ensure easy connection to the metal connectors of the electrodes. When the device units lock onto the electrodes properly, you hear a click. Note:You can wear the electrodes with the device units attached to them under your clothes, also during treatment. Note: Consult the electrode placement guide for the recommended position for the electrodes during treatment.This is only a recommendation.You can perform all activities allowed as intended use and not warned against in chapter ‘Important safeguards’ when you wear the device on your body.You can also continue to wear the device on your body in between treatments. Electrode placement If you want the best results from using this device, make sure that you place the electrodes correctly. Do not use the device on skin that lacks normal sensation.You may have to move the electrodes a few times to find the optimal place. In some cases, it can be helpful to mark the spot. At the back of this user manual, you find the electrode placement guides for TENS and EMS.They give suggestions for places where you can attach the electrodes. Place the electrodes on or near the treatment area.You may need assistance when you want to attach electrodes to hard-to-reach spots. Use of the device may lead to visible muscle contractions, especially in burst TENS programs (programs 7 to 11). These contractions are not harmful. If they are uncomfortable, move the electrodes to a different place. Be aware that muscle contraction is a desired effect in EMS programs (programs 16 to 20). If no contraction occurs in an EMS program, the electrode is not placed correctly, or the intensity is too low. ENGLISH 23 Using the app to start and stop a treatment 1 Turn on Bluetooth on your mobile device. Your devices Cancel Philips PulseRelief PR3094/00 Product ID: 12345678901234567890 Software version: 12345678901234567890 Forget my device Clear my history Philips BlueTouch PR0000/00 Product ID: 12345678901234567890 Software version: 12345678901234567890 Forget my device Clear my history 3 Open the Philips Treatment App. Add new PulseRelief Treatment area Cancel Skip Rotate to select treatment area Treatment area Cancel 2 Use the on/off button to set the device to standby. ,, The status indicator on the device lights up solid green to indicate that the device is in standby mode and ready for treatment. ,, If you do not start the treatment within 5 minutes, the device turns off automatically. If this happens, you first have to press the on/off button again to start a treatment. Skip Selecting a treatment area At first-time use, you always have to select a treatment area. If you have used the device before, you can choose between ‘My previous treatment’ to repeat the previous treatment and ‘Select new treatment’ to start a different treatment. 1 Rotate the body animation on the screen. 2 Tap on one of the suggested locations for the electrodes to select the area you want to treat. Next Rating your pain intensity › Your pain level Skip 10 none moderate extreme Next 1 Swipe vertically to rate the intensity of your pain on a scale from 0 to 10. If you experience no pain tap 0 and if you experience the worst pain ever tap 10. If your pain is somewhere in between, rate it by tapping the appropriate number. ENGLISH 24 Select treatment › Conventional no limit May give you a continuous tingling stimulation Thorough stimulus no limit May give you a more thorough stimulating sensation Gentle massage 30 min May give you a mild flowing stimulation sensation Soft stimulus no limit May give you a softer stimulating sensation, e.g. for sensitive body parts Continous Burst 30 min May give you a pulsing burst stimulation to release endorphins in your body no limit Pre-activity PulseRelief Selecting your treatment 1 Scroll through the list of programs and tap a program to select it. 2 The start screen of the treatment appears. › Gentle massage 30:00 Starting and stopping a treatment 1 Tap the play button on the screen. ,, The treatment screen opens and the time starts to count down. ,, The status indicator on the device starts to flash orange. PulseRelief Gentle massage 34 27:58 2 On the treatment screen, you can tap the + or the - to increase or decrease the intensity to a comfortable level. PulseRelief Gentle massage 27:58 Continue Note:The pain intensity you indicate is not used by the app to determine the intensity of the treatment. The rating is only stored in your treatment diary.You can turn off this feature in the settings tab of the app. End 3 In programs with a specified maximum treatment time, treatment continues until the timer has counted down to 0. In programs that have no specified maximum treatment time, the timer counts up from 0. It continues to count up until you stop the treatment. If you want to stop or interrupt the treatment, tap the square in the center of the pulsing treatment indicator to stop the program. -- To resume the program, tap ‘Continue’ or the arrow next to the time. -- To end the program, tap ‘End treatment’. › ENGLISH 25 Switching to another program 1 If you want to switch to another treatment program while a program is running: -- on a smartphone or iPod, tap the name of the program in the treatment screen. -- on a tablet, tap ‘Treatment list’ 2 The list of programs opens. Tap the treatment program you want to use. 3 The start screen of the treatment appears. Tap the play button to start the treatment. 4 Tap the + to increase the intensity to a comfortable level. Note:When you switch to another program during treatment, the intensity is automatically reset to 0. This is a safety measure.The intensity level of the previous program may be too high for the new program. Adapting the treatment time 1 Tap the time displayed in the treatment screen. 2 Change the remaining treatment time. Quick start From the start screen, you can immediately start the program you used during your previous treatment. 1 From the start screen, tap the name of the treatment under ‘My previous treatment’. 2 Swipe vertically to rate the intensity of your pain on a scale from 0 to 10. 3 Start the treatment. ENGLISH 26 Other app features My treatment Cancel Treatment type Gentle massage Date 2014 / 04 / 11 Duration 40 minutes Intensity ave. 34 Treatment area Upper leg My pain level 3 / 10 19:43 How do you feel now? Rate your treatment Fatigued Same Relaxed Energized 1 After the program finishes, you get to a screen that asks you to describe how you feel. You can indicate this by tapping one of the icons. Done My treatment diary 2014 / 04 / 12 11:08 Gentle massage 2014 / 04 / 12 11:08 Gentle massage 2014 / 04 / 12 11:08 Gentle massage › › › 2014 / 04 / 12 11:08 Gentle massage 2014 / 04 / 12 11:08 › › 2 Tap the book symbol to open your diary. The diary shows when treatments took place, which program you used and how long the treatment lasted. -- Tap the arrow to see more details. Information Using your PulseRelief Troubleshooting Contact us Setttings Your devices Pain level tracking Sensation tracking Treatment area tracking Run treatment in background About › 3 Tap the ‘i’ to open the information screen. This screen contains the following items: -- Using your PulseRelief -- Contact us 4 Tap the settings symbol to open the settings screen. This screen contains the following items: -- Your devices -- Pain level tracking -- Sensation tracking -- Treatment area tracking -- Run treatment in background -- About Using a second device To treat a larger area of the body or to treat different body areas at the same time, you can pair a second PulseRelief device to the app. ENGLISH 27 Cancel Your devices Philips PulseRelief PR3094/00 Product ID: 12345678901234567890 Software version: 12345678901234567890 Forget my device Clear my history Philips BlueTouch PR0000/00 Product ID: 12345678901234567890 Software version: 12345678901234567890 Forget my device Clear my history 1 Tap the settings symbol and then tap ‘Your Devices’. 2 At the bottom of the screen, tap the device you want to pair: PulseRelief. Add new PulseRelief 3 Turn on the device when the app tells you to. To pair device, press power button for about 5 seconds until green light 4 The app enters pairing mode. Paired! 5 When the device is paired to the app, the smart phone icon disappears and only the device is shown. 6 Tap ‘Back’ to go back to the treatment screen. After use Caution: Always end the treatment in the app or by pressing the on/off button before you remove the device or the electrodes. If you fail to do this, you may get an unpleasant sensation in your fingers when you touch the connectors. This sensation is not harmful, but it can be unpleasant 28 ENGLISH 1 Press the on/off button to turn off the device. 2 Detach the device from the electrodes by pulling it off. Note: If you forget to turn off the device, it will turn off automatically after 5 minutes. 3 If you have used the device several times in one day, recharge it before your next treatment. 4 Peel the electrodes off the skin by pulling at the edge. Note:You can continue to use the electrodes at the same spot if treatment is still effective. If it is no longer effective, move the electrodes to a different spot. You also have to move the electrodes to a different spot if the skin under the electrodes becomes irritated. Care for and storage of the electrodes 1 Place the electrodes back on the liner. 2 Slide the liner with the electrodes back into the bag. ENGLISH 29 3 Reseal the bag for dust-free storage. Note:To keep the electrodes in good condition and to prevent the hydrogel layer from drying out, always store them in the resealable bag when they are not attached to your body for treatment. Seal the resealable bag to guarantee dust-free storage. Note: If you want to store electrodes for more than a month, keep them at temperatures between 41°F (+5°C) and 80.6°F (+27°C). Do not store the electrodes in the freezer or the refrigerator. Avoid high temperatures and exposure to direct sunlight. Cleaning Do not immerse the device in water or rinse it under the tap. Do not immerse the electrodes in water. 1 Clean the device with a damp cloth and a mild cleaning agent, e.g. dishwashing liquid. Note:You can also clean the device with 70% isopropyl alcohol (IPA). Caution: Do not use any other cleaning agents than the ones mentioned above, as other cleaning agents could damage the material, e.g. cause loss of gloss. 2 If the electrodes are dirty, put a drop of water on your finger and gently rub the dirt off the surface. Note: Do not use soap or alcohol to clean the electrodes. 30 ENGLISH This device has no other serviceable parts. Call call toll-free 1-844-531-6861 (Monday - Saturday 9:00 AM - 9:00 PM EST, Sunday 9:00 AM – 6:00 PM EST, excluding Major Holidays) for assistance. Assistance For assistance, visit our website www.philips.com/ support or call toll-free 1-844-531-6861 (Monday - Saturday 9:00 AM - 9:00 PM EST, Sunday 9:00 AM – 6:00 PM EST, excluding Major Holidays). Online information is available 24 hours a day, 7 days a week. Troubleshooting This chapter summarizes the most common problems you could encounter with the PulseRelief. If you are unable to solve the problem with the information below, visit www.philips.com/support for a list of frequently asked questions or contact the Philips Consumer Care Centre in your country. Problem Possible cause Solution The battery indicator on the device was orange and then the device turned off. The battery is empty. Charge the device (see chapter ‘Preparing for use’). The battery indicator on the device is solid orange. The battery is low. This means that the battery has 30% of its capacity left. Recharge the device as soon as possible (see chapter ‘Preparing for use’). ENGLISH 31 Problem Possible cause Solution I experienced an unpleasant sensation when I touched the connectors of the device or the electrodes. You did not end the treatment in the app or did not press the on/off button on the device before you removed the device. Always end the treatment in the app or press the on/off button on the device before you remove the device from your skin. In this way, you avoid the unpleasant sensation when you touch the connectors of the device or touch the electrodes. This sensation is unpleasant but not harmful. The treatment feels different or less pleasant than usual. The intensity is too high or too low. On the program settings screen in the app, tap + or - to increase or decrease the intensity. You can also choose a different treatment program. The electrodes are not in the right place. Turn off the device and detach it from the electrodes. Remove the electrodes from the skin and move them to a slightly different place. The electrodes are not properly attached. Turn off the device and detach it from the electrodes. Check if the electrodes are attached to the skin properly. The electrodes are too dirty. Clean the electrodes (see chapter ‘Cleaning’). If this does not help, replace the electrodes. 32 ENGLISH Problem Possible cause Solution The electrodes are worn. Replace the electrodes immediately. You are using electrodes that are past their use-by date. Remove the electrodes and use new ones that are not past their use-by date. Replacement Electrodes Replace the electrodes if: -- they are damaged or torn. -- they are past the use-by date indicated on the resealable bag. -- they have lost their adhesive power. Never use plaster or tape to attach them to your skin. -- stimulation feels less strong. -- when stimulation is uncomfortable, i.e. when you experience an unpleasant stinging or biting sensation. Note: Always replace the electrodes with electrodes recommended for this device by the manufacturer. Accessories PulseRelief accessories may be purchased at a store near you or on our website www.philips.com/store. Caution: Only use this device with the adapter, cord and electrodes recommended by the manufacturer. ENGLISH 33 Full Two-Year Warranty Philips Electronics North America Corporation warrants each new Philips product, Model PR3841, against defects in materials or workmanship for a period of two years from the date of purchase, and the electrode pads for 30 days, and agrees to repair or replace any defective product without charge. IMPORTANT: This warranty does not cover damage resulting from accident, misuse or abuse, lack of reasonable care, the affixing of any attachment not provided with the product or loss of parts or subjecting the product to any but the specified voltage.* Use of unauthorized replacement parts will void this warranty. PHILIPS ELECTRONICS NORTH AMERICA CORPORATION WILL NOT PAY FOR WARRANTY SERVICE PERFORMED BY A NON-AUTHORIZED REPAIR SERVICE AND WILL NOT REIMBURSE THE CONSUMER FOR DAMAGE RESULTING FROM WARRANTY SERVICE PERFORMED BY A NON-AUTHORIZED REPAIR SERVICE. NO RESPONSIBILITY IS ASSUMED FOR ANY SPECIAL, INCIDENTAL OR CONSEQUENTIAL DAMAGES. In order to obtain warranty service, simply go to www.philips.com or call toll-free 1-844-531-6861 (Monday - Saturday 9:00 AM - 9:00 PM EST, Sunday 9:00 AM – 6:00 PM EST, excluding Major Holidays) for assistance. It is suggested that for your protection you return shipments of product by insured mail, insurance prepaid. Damage occurring during shipment is not covered by this warranty. NOTE: No other warranty, written or oral, is authorized by Philips Electronics North America Corporation. 34 ENGLISH This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above exclusion and limitations may not apply to you. * Read enclosed instructions carefully. In U.S. only manufactured for: Philips Consumer Lifestyle, A Division of Philips Electronics North America Corporation, P.O. Box 10313, Stamford, CT 06904. This symbol on the product’s nameplate means it is listed by TÜV Rheinland US PHILIPS and Philips Shield are Registered Trademarks of Koninklijke Philips N.V. © 2015 Philips Electronics North America Corporation. All Rights Reserved. 45-Day Money-Back Guarantee If you are not fully satisfied with your Philips PulseRelief send the product back and we’ll refund you the full purchase price.The PulseRelief must be shipped prepaid by insured mail, insurance prepaid, have the original sales receipt, indicating purchase price and date of purchase, and the money-back guarantee return authorization form enclosed. We cannot be responsible for lost mail. The PulseRelief must be postmarked no later than 45 days after the date of purchase. Philips reserves the right to verify the purchase price of the product and limit refunds not to exceed suggested retail price.To obtain money-back guarantee return authorization form, call toll-free 1-844-531-6861 (Monday - Saturday 9:00 AM - 9:00 PM EST, Sunday 9:00 AM – 6:00 PM EST, excluding Major Holidays) for assistance. Delivery of refund check will occur 6–8 weeks AFTER receipt of returned product. ENGLISH 35 Battery recycling -- This Philips Pulse Relief contains a rechargeable Lithium-Ion battery which must be disposed of properly. -- Contact your local town or city officials for battery disposal information. You can also call 1-800-8-BATTERY or visit www.rbrc.com for battery drop-off locations. -- For assistance, visit our website www.philips.com/support or call toll-free 1-844-531-6861 (Monday - Saturday 9:00 AM - 9:00 PM EST, Sunday 9:00 AM – 6:00 PM EST, excluding Major Holidays). 36 ENGLISH Compliance information -- This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Radio interference This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment to an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. ENGLISH 37 RF Radiation Exposure Statement This equipment complies with FCC RF radiation exposure limits set forth for an uncontrolled environment. For handheld/body-worn operation, this equipment has been tested and meets the FCC RF exposure guidelines. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. Use of other accessories may not ensure compliance with FCC RF guidelines. Do not attempt to repair or modify this equipment. Any repairs or alterations made by the user to the equipment may void the warranty and compliance of the equipment. Changes or modifications made to this equipment not expressly approved by Philips may void the FCC authorization to operate this equipment. For assistance visit our website www.philips.com/support or call toll-free 1-844-531-6861 (Monday - Saturday 9:00 AM - 9:00 PM EST, Sunday 9:00 AM – 6:00 PM EST, excluding Major Holidays). Electromagnetic emissions and immunity The PulseRelief device is approved according to electromagnetic compatibility (EMC) safety standard EN 60601-1-2. It is designed to be used in typical domestic environments. 38 ENGLISH Specifications Model PR3841 Rated voltage(V) - adapter 100-240 ~ 150mA Rated frequency (Hz) - adapter 50-60 Rated output - adapter 5V , 300 mA Class Medical device Class 2 Ingress of water - device IP22 Self-adhesive hydrogel electrode 2.16in (50mm) x 2.16in (50mm) Battery type - device Li-Ion Adapter The adapter is specified as part of the device Pulse output parameters Frequency range 1-100 Hz Pulse duration 60-350 µs for programs 1 to 20 Maximum current output 60mA at 500-1000 Ohm Maximum output voltage 60V Current pulse shape Biphase symmetrical (net current 0 DC) ENGLISH 39 Operating conditions Temperature from 41°F (+5°C) to 104°F (+40°C) Relative humidity from 15% to 93% (non-condensing) Atmospheric pressure from 700hPa to 1060hPa Storage and transport conditions Temperature - electrodes from 32°F (0°C) to 104°F (+40°C) Temperature - device from 14°F (-10°C) to 122°F (+50°C) Relative humidity less than 93% (non-condensing) Atmospheric pressure from 700hPa to 1060hPa Note: If you want to store the electrodes for more than a month, keep them at temperatures between 41°F (+5°C) and 80.6°F (+27°C). Note: Do not store the electrodes in the freezer or refrigerator. Do not expose them to high temperatures, nor immerse them in water, or leave them outside of the plastic bag. Program specifications The table below gives information on the frequency, pulse width and pre-set time of each program. The current pulse in all programs has a symmetrical bi-phase waveform. 40 ENGLISH Program name Program type Frequency Pulse width Pre-set time Conventional Conventional 100 Hz 200µs continuous Thorough stimulus Conventional 40 Hz 200µs continuous Pre-activity Conventional 100 Hz 150µs continuous Soft stimulus Conventional 80 Hz 60µs continuous Deep stimulus Conventional 80 Hz 150µs continuous Radiating Pulse Conventional 60 Hz 150µs continuous Continuous burst Burst 100 Hz, 2 Hz 250µs 30 min. Slow kneading Burst 80 Hz, 1 Hz 200µs 30 min. Mild kneading Burst 80 Hz, 3 Hz 200µs 30 min. Deep kneading Burst 80 Hz, 2 Hz 150µs 30 min. Diffuse burst Burst 80 Hz, 2 Hz 180µs 30 min. Mixed frequency Freq. Mod. 8-100 Hz 250µs 30 min. Pulsing massage Freq. Mod. 2-8 Hz 250µs 30 min. Deep massage Freq. Mod. 2-80 Hz 180µs 30 min. Gentle massage Freq. Mod. 8-80 Hz 150µs 30 min. Muscle stimulation Ampl. Mod. pulse 40 Hz 200µs 30 min. Muscle stimulation Ampl. Mod. flow 50 Hz 150µs 20 min. ENGLISH 41 Program name Program type Frequency Pulse width Pre-set time Muscle stimulation Ampl. Mod. wave 65 Hz 200µs 30 min. Muscle stimulation Ampl. Mod. flux 40 Hz 350µs 25 min. Muscle stimulation Ampl. Mod. bounce 50 Hz 300µs 20 min. Explanation of symbols Symbols on the adapter and the device -- This symbol indicates that the adapter is double insulated (Class II) and complies with IEC 60601-1. -- This symbol indicates that you must not throw away the adapter and device with the normal household waste. For instructions on disposal of the battery, see chapter ‘Battery recycling’. -- This symbol is the certification logo that identifies the accredited compliance test house. 42 ENGLISH Symbols on the device -- This symbol indicates the serial number. It is followed by the serial number of the device. -- This symbol indicates the reference number of the manufacturer. It is the type number of the device. -- This symbol indicates the degree of protection. It indicates that the hazardous parts inside the device cannot be accessed with a finger. It also indicates that vertically falling water drops will not damage the device when tilted up to 15 degrees. -- This symbol means that, in compliance with IEC 60601-1, the part of the device that comes into physical contact with the user, i.e., the applied part, is of type BF or Body Floating type. The applied parts are the electrodes. -- This symbol means that this device emits non-ionizing radiation. All devices with RF transmitters or that use RF electromagnetic energy must have a label with this symbol. ENGLISH 43 -- This symbol means: caution TENS output. You find this symbol near all electrode connections. -- This symbol indicates the manufacturer. It appears next to the legal address of the manufacturer. -- This symbol means that the device conforms to EC Directives. 0344 is the number of the notified body. -- This symbol tells users to read the user manual before they start using the device. -- This symbol is the standby symbol. It appears next to the button that sets the device to standby. 44 ENGLISH -- This is the pulse symbol. It appears next to the status indicator. -- This is the battery symbol. It appears next to the battery indicator. -- This symbol is a certification mark. It is used on electronic products manufactured or sold in the United States. It confirms that the electromagnetic interference from the device is lower than the limits approved by the FCC. Symbols on the adapter -- This symbol means: alternating current. -- This symbol means: direct current. ENGLISH 45 -- This symbol means that the adapter conforms to EC Directives. -- This symbol means that the adapter may only be used indoors. -- This symbol indicates the USB connector. -- This symbol indicates the micro-USB connector. -- This symbol is the certification mark for technical equipment. The GS mark is based on the German Equipment and Product Safety Act. -- This symbol shows that the no-load power CEC Efficiency Level is 5 in order to meet EU requirements. 46 ENGLISH Symbols on electrode bag The symbols on the electrode bag mean the following. -- Do not use the device while driving, operating machines, or performing other activities that may present a risk of injury. -- Do not use damaged or worn electrodes or electrodes that have lost their adhesive power. -- The electrodes may only be used by one person. Do not share them with another person. -- Do not place the electrodes on top of each other, or so close to each other that they touch each other. -- Do not place electrodes on your head or on your neck. ENGLISH 47 -- Do not place the electrodes on your chest. 80.6°F +27°C 41.0°F +5°C -- Use the device only on normal, intact, clean, and healthy skin. ,, Do not use the device over open wounds or rashes, and over swollen, red, infected, or inflamed areas or skin eruptions (e.g., phlebitis, thrombophlebitis, varicose veins). -- Do not use the device over, or close to, cancerous lesions. -- This symbol indicates the minimum and maximum storage temperatures that apply if electrodes are stored for more than one month. -- This is the use-by symbol. It indicates after which date you must not use the electrodes anymore. -- This symbol indicates the manufacturer’s batch code so that the batch or lot can be identified. -- This symbol indicates the expiry date. After this date you must not use the electrodes anymore.Electrode placement guide 48 ENGLISH TENS For a description of the TENS programs (programs 1 - 15), refer to chapter ‘Pre-set programs’. ENGLISH 49 EMS For a description of the EMS programs (programs 16 - 20), refer to chapter ‘Pre-set programs’. 50 51 4222.100.3688.1
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Creator : Adobe InDesign CC 2014 (Macintosh) Modify Date : 2015:06:24 17:13:46+02:00 XMP Toolkit : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04 Metadata Date : 2015:06:24 17:13:46+02:00 Creator Tool : Adobe InDesign CC 2014 (Macintosh) Instance ID : uuid:b7153f70-dcbd-4b8b-a2bd-20b5a742afe8 Original Document ID : adobe:docid:indd:2c3d3668-ef10-11e4-b006-8af3f655cf0b Document ID : xmp.id:7ac9a92d-dcfd-4369-af66-35888ce2415c Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:2e29dc05-f466-4a7b-a73a-7ba166a1c51b Derived From Document ID : xmp.did:a61b54d7-c745-4100-9103-07553010a269 Derived From Original Document ID: adobe:docid:indd:2c3d3668-ef10-11e4-b006-8af3f655cf0b Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2014 (Macintosh) History Changed : / History When : 2015:05:11 09:51:14+02:00 Format : application/pdf Phsprop 2 : 1000 series Create Date : 2005:12:01 12:32:37Z Ww numpages : 56 Ww pagecnt Back Outside : 1 Ww pagecnt Cover Outside : 1 Ww pagecnt Fold Out : 4 Ww pagecnt Cover Inside : 1 Ww pagecnt Back Inside : 1 Ww pagecnt TOL : 1 Ww pagecnt Content : 44 Ww pagecnt lang : EN:44; Producer : Adobe PDF Library 11.0 Trapped : False Page Layout : SinglePage Page Mode : UseOutlines Page Count : 52EXIF Metadata provided by EXIF.tools