Philips Medical Systems North America WMTS-MODULE WMTS Radio Module User Manual Application Note
Philips Medical Systems North America Co. WMTS Radio Module Users Manual Application Note
Contents
- 1. Users Manual Application Note
- 2. USERS MANUAL
Users Manual Application Note
Page 1 of 6 Philips Medical Systems Patient Monitoring Quality & Regulatory Group 3000 Minuteman Road Mailstop 0490 Andover, MA 01810 Tel: (978) 659-7383 Fax: (978) 685-5624 Application Note: WMTS-MODULE Prepared by: Last revised: Juan Brea 10-Mar-05 The following information is intended for Philips internal use only. It is a guide for the incorporation of the WMTS-MODULE into Philips patient monitoring medical devices. Interested Philips engineers should contact the Wireless ER Manager for additional information and referral to specific design specialists. This document is an internally controlled document under the Philips Quality System. Page 2 of 6 Table of Contents Table of Contents ..................................................................................................................... 2 Introduction............................................................................................................................... 3 Host Interface ........................................................................................................................... 3 Serial Connection ..................................................................................................................... 4 4.1 Serial Specification:........................................................................................................... 4 4.2 Maximum User Data Rate:................................................................................................ 4 WMTS-MODULE RF Shielding. ............................................................................................... 4 WMTS-MODULE Mounting Considerations............................................................................. 5 RF Input/Output, Antenna ........................................................................................................ 5 7.1 RF Transmitter Specifications........................................................................................... 5 Fault Conditions ....................................................................................................................... 5 8.1 Over/ Under Voltage ......................................................................................................... 5 8.2 Excessive Signal Level on Serial Input ............................................................................. 6 8.3 Excessive Data Rate on Serial Input ................................................................................ 6 Accompanying Documentation for products incorporating the WMTS-MODULE.................... 6 Page 3 of 6 Introduction The WMTS-MODULE is a serial network adapter designed to be used with specialized medical devices manufactured by Philips Medical Systems (Figure 1). It enables the host medical device to wirelessly establish bi directional communication with other remote devices using the Philips’ WMTS infrastructure. RF antenna Sheet Metal Housing +5 Vdc Coaxial RF cable Serial Data Radio Module Ground Figure 1: WMTS-MODULE Block Diagram Host Interface The WMTS radio module interfaces to the host though a single I/O connector (Figure 2). Via this connector the host must supply DC power, signal ground and modulating data to the radio module. The communication between the host device and the radio module is a two wire asynchronous serial interface (Table 1). WMTS Radio 6 pin header AMP 7 -338069-6. Figure 2: WMTS-MODULE Interface Host Connector Page 4 of 6 Pin Name Ground ITS_Tx I/O OUT Function First of two ground connections for the module. Serial data to host. ITS_Rx IN Serial data from host. Ground +5 vdc Second of two ground connections for the module. + 5 vdc +/- 5%, Sinks 35 mA average, 280 mA Peak during radio Tx/Rx Not Connected Table 1: Host Connector pin assignment 4.1 Serial Connection Serial Specification: The interface to the Host is a serial communication link (Table 2): Æ Flow Control: Æ Baud Rate: Æ Parity: Æ Bits: Æ Logic Levels: Tx, Rx; no hardware flow control 115.2 kbaud; No parity bit 8 bits of data, plus 1 Start/Stop bits TTL levels, 5 volt tolerant. ITS_Tx Logical Zero LOW 0.1 V max 0.55V max Logical One HIGH 2.9V min 2.3V min ITS_Rx 0.6V max 2.2V min Table 2: Serial Lines, Electrical DC Characteristics 4.2 Conditions 100uA sink 24mA sink 100uA load 24mA load Maximum User Data Rate: The maximum user data rate that the radio supports is 12 kbits/second in each direction. This maximum over the air data rate is fixed by design and cannot be modified by the user. WMTS-MODULE RF Shielding. The module contains all necessary RF shielding. The host device does not need to provide additional shielding. Page 5 of 6 WMTS-MODULE Mounting Considerations. The module is self-contained and can be mounted anywhere using the supplied threaded pem nuts. No special heat sinking considerations are required. There are no orientation constraints. RF Input/Output, Antenna The WMTS Radio Module is only approved for use with the antenna specified by Philips, part number M4842-61300. This antenna cannot be replaced with an antenna of a different type. The RF input and output of the WMTS-MODULE is matched to 50 ohms. A coaxial cable brings the RF outside the metal enclosure. This cable uses a unique non standard connector manufactured by JST (JST part number AYUI-1S-12676-221). The coaxial cable connects to a JST to reversed TNC adapter made by Amphenol (Amphenol part number 031-6101) where the antenna plugs in. The antenna is made by Radial to Philips’ specifications (Philips specifications number A-M484261300-1, rev A). 7.1 RF Transmitter Specifications The following table summarizes general transmitter specifications (Table 3). For complete details (including details on the receiver section) refer to ES-M4840-90108: 1. Frequency ranges: Bands: 1395 - 1400 MHz and 1427 - 1432 MHz 2. RF Output Power 8 dBm +2/-3dB, 6.3 mW (3.2 mW to 10 mW), into Antenna load. Calibrated into 50 ohms. 3. RF Output Power control a) Transmitter chain gain shall be calibrated at time of manufacture (env temp 25+/-5deg.C). b) Over power algorithm deployed to prevent excess power and also includes temperature compensation. 4. Transceiver frequency accuracy +/-15KHz relative to channel frequency, includes temperature compensation & aging effects. 5. Reference Frequency Calibration <4ppm 6. Modulation type FSK with Root Raised Cosine filtering (1M60Q7D) Table 3: WMTS Radio Module, Transmitter Specifications 8.1 Fault Conditions Over/ Under Voltage The input voltage from the DC power source to the module must remain between the values specified in Table 1. Operating the radio module from a voltage lower source lower than 4.75VDc or higher that 5.25 vdc can cause the regulator section to shut down ceasing operation of the radio module. Page 6 of 6 8.2 Excessive Signal Level on Serial Input The data input signal levels must be observed as specified in Table 2. Driving the input data line over 5 vdc can cause damage to the radio module input buffers, causing interruption of data transfer. 8.3 Excessive Data Rate on Serial Input The host serial communication data rate is fixed at 115.2 kbaud. Clocking data at different baud rates will result in incorrect data transfer. The maximum host/user over the RF link data rate is 12 kbps. Attempting to send data at a faster rate will result in data buffer overrun and data loss. Accompanying Documentation for products incorporating the WMTS-MODULE Products which incorporate this device will be labeled “Contains PQC-WMTS-MODULE”, and their accompanying documentation will also advise the user concerning frequency coordination (47 CFR 95.1109), as follows: “Operation of this equipment requires the prior coordination with a frequency coordinator designated by the FCC for the Wireless Medical Telemetry Service.”
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : No Create Date : 2005:03:10 19:28:23Z Modify Date : 2005:03:10 14:29:25-05:00 Page Count : 6 Creation Date : 2005:03:10 19:28:23Z Mod Date : 2005:03:10 14:29:25-05:00 Producer : Acrobat Distiller 5.0.5 (Windows) Author : usd05766 Metadata Date : 2005:03:10 14:29:25-05:00 Creator : usd05766 Title : Microsoft Word - Philips_Instructions_for_Use_Application_Note_WMTS-MODULE..EXIF Metadata provided by EXIF.tools