Philips 863283 Object Moved User Manual Product Brochure Sure Signs Vital Monitor VS4 4effc67e70b64f0abe31a77c0161a8e3
User Manual: Philips 863283 Product Brochure Philips SureSigns Vital signs monitor VS4 Philips - SureSigns VS VS4 Vital signs monitor863283
Open the PDF directly: View PDF .
Page Count: 1
Download | |
Open PDF In Browser | View PDF |
SureSigns VS4 vital signs monitor Act. Don’t react. Spot subtle but significant deterioration early Now vital signs can count for more. The SureSigns VS4 helps you track subtle signs of deterioration so you can document and escalate effectively. It simplifies your workflow with an intuitive touchscreen interface, and provides time-saving tools like QuickCapture and QuickCheck for documentation, and QuickAlerts (single- or multi-parameter modified Early Warning Scoring) to activate your hospital’s Rapid Response Team (RRT) as appropriate. Now you can act decisively to provide targeted care when it can do the most good. Because it’s wiser to act rather than react. Key advantages • Brings configurable Early Warning Scores to the bedside to help you identify subtle signs of patient deterioration for decisive action • Provides intuitive tools, such as QuickCapture to simplify documentation, and QuickAlerts to highlight patient deterioration for escalation • Offers desired interfacing, using standard networking infrastructures and the latest security and encryption1 Specs that matter, clinical benefits that count Now there’s a vital signs monitor that helps you identify subtle signs of patient deterioration early and act decisively. Alternate between spot check and frequent measurement of vitals. Capture and check values. Streamline your workflow. Simplify your workflow • Touchscreen: color LED backlit screen • Connect with IntelliVue Guardian software (MEWS) • QuickCheck -- Caregiver authentication at the bedside -- Patient record validation at the bedside -- Patient record review before export to EHR • QuickCapture -- Customize up to 40 observation and assessment entries for fast recall and reuse • QuickAlerts -- Choose Single or Modified Early Warning Scoring at the bedside, including detection of patient deterioration • QuickNBP -- Provides fast NBP measurements -- One-touch NBP on/off button • SpO2 -- Choice of Philips FAST-based SpO2 algorithm or Masimo® SET® or rainbow® SpO2 (including certain Masimo rainbow parameters) -- Either choice is compatible with a wide variety of sensors • Microstream™ etCO2 option -- Includes Integrated Pulmonary Index (IPI) • Temperature choices -- Welch Allyn® Predictive, Covidien™ tympanic, or Exergen® temporal • Biomedical and IT device maintenance tool kit • Exergen TemporalScanner™ thermometer option -- With optional disposable covers for cost-savings • 1D/2D/RFID barcode scanner -- Programmable to support consistent and reliable patient ID entry 2 Other benefits • Uses same supplies as all Philips monitors • Time-sync with hospital or network clock • Stores up to 800 patient records • Confirmation of exported records easily seen in green • LAN/serial data export in HL7 format • Internal WiFi – 802.11 a/b/g option • USB port for easy software upgrades and to import configuration settings • Nurse call output • Lithium ion battery • Battery management, including a visible icon to show unit is plugged in and charging • AC power input with power cord clip • Sturdy handle and rugged housing for easy portability • Compatible with SureSigns Dashboard Easy to use, easy to maintain Product specifications Width, height, W: 26 cm (10.2 in), H: 22 cm (8.6 in), depth D: 14.5 cm (5.7 in) Weight 3.6 kg (8 lb) Screen 21.3 cm (8.4 in) SVGA TFT-AM LCD, resistive touchscreen, 800 active pixels/line Resolution: 600 active lines per frame Viewing angle: ±60 degrees NBP CO2 • Oscillometric using stepwise deflation pressure – NBP interval choices • Adult measurement range – Systolic: 30 – 270 mmHg (4.0 – 36.0 kPa) – Diastolic: 10 – 245 mmHg (1.3 – 32.7 kPa) – MAP: 20 – 250 mmHg (2.7 – 34.0 kPa) • Pediatric measurement range – Systolic: 30 – 180 mmHg (4.0 – 24.0 kPa) – Diastolic: 10 – 150 mmHg (1.3 – 20.0 kPa) – MAP: 20 – 160 mmHg (2.7 – 21.3 kPa) • Neonatal measurement range – Systolic: 30 – 130 mmHg (4.0 – 17.0 kPa) – Diastolic: 10–100 mmHg (1.3 – 13.3 kPa) – MAP: 20 – 120 mmHg (2.7 – 16.0 kPa) • The NBP measurement has an accuracy over the ranges listed for these values – Maximum standard deviation: 8 mmHg – Maximum mean error: ±5 mmHg • Subsequent cuff inflation (in NBP interval mode only) – The subsequent inflation pressure is determined automatically depending on the previous measurement and patient type Measurement range: 0 mmHg – 150 mmHg Total response time for adults: 3.9 seconds Accuracy: 0 mmHg – 38 mmHg: ±2 mmHg 39 mmHg – 150 mmHg: ±(5% of reading + 0.08% for every 1 mmHg above 38 mmHg) Respiration rate range: 1 – 150 bpm Respiration accuracy: ±1 bpm in the range of 0 – 70 bpm, ±2 bpm in the range of 71 – 120 bpm, ±3 bpm in the range of 121 – 150 bpm SpO2 Philips FAST-based Meets EN ISO 9919 standard Measurement range: 0 – 100% Pulse rate measurement range: 30 bpm – 300 bpm Pulse accuracy: within 2% or 1 bpm SpO2 Masimo SET and rainbow SpO2 measurement range: 0 – 100% SpO2 accuracy: depends upon patient type and motion/no motion SpHb measurement range, no motion: 0 – 25.0 g/dL SpHb accuracy: ±1 g/dL over range of 8 – 17 g/dL RRa measurement range: 0 breaths per minute to 70 breaths per minute RRa accuracy: 4 breaths per minute to 70 breaths per minute, ±1 breath per minute SpHb and RRa are only supported on adult and pediatric patients (>10 kg) Temperature Welch Allyn® predictive Modes: predictive and monitored Probe sites: oral, rectal, or axillary Range: Monitor mode: 26.7 – 43.3 °C (80.1 – 109.9 °F) Predictive mode: 34.4 – 40.6 °C (93.9 – 105.1 °F) Accuracy: ±0.1 °C (±0.2 °F) Measurement time: 4 - 6 seconds Temperature Covidien™ tympanic Equivalency modes: ear (no adjustment), oral, core, and rectal (adjusted from ear) Range: 33 – 42.0 °C (91.4 – 107.6 °F) Accuracy (overall range): ±0.2 °C (±0.4 °F) Measurement response time: ≤ 2 seconds Temperature Exergen® temporal Range: 16 – 43 °C (60.8 – 109.4 °F) Accuracy: ±0.1 °C (±0.2 °F) Response time: approximately 1 second IntelliVue Guardian software Adult only Battery Lithium ion, 10.8 – 11.1 V Data output HL7 format, via Ethernet port Serial data Patient type Adult, pediatric, neonatal EWS system would be a major change “An in the hospital, especially from the nursing and medical records perspective.” Archie Marangos, Biomed, Tufts Medical Center, Boston, MA 3 Make vital signs count for more Catch the subtle signs that signal patient deterioration. With the SureSigns VS4, you can act, not just react. Ordering information Parameters To order Also available To order NBP, FAST-based SpO2 863283 A01 SureSigns premium rollstand 989803176601 SpO2 and NBP accessories included No accessories A02 SureSigns standard rollstand 989803144001 Wall mount 989803144011 2D barcode scanner 989803147821 2D barcode scanner holder 989803191611 HS-1 2D barcode scanner 989803176611 HS-1 barcode scanner roll-stand insert 989803184701 Temperature Welch Allyn predictive temperature T01 Covidien tympanic temperature T02 Exergen temporal temperature T03 Exergen temporal cap holder C05 SpO2 Masimo SET SpO2 M01 Masimo rainbow SpO2, SpHb M02 Masimo rainbow SpO2, RRa M03 Serial interface adapter 989803159601 Masimo SpO2 LNCS cable C01 Wireless upgrade kit 989803181201 Masimo SpO2, SpHb cable C02 Tympanic temperature upgrade kit 863293 Masimo SpO2, SpHb, RRa cable C03 Masimo SpO2, SpHb/LNCS, RRa cable C04 Adult NBP cuff N01 Capnography Microstream CO2 E01 Other 1 FIPS (US only) F01 IntelliVue Guardian software G01 Recorder R01 802.11 a/b/g wireless W01 Predictive temperature 863294 upgrade kit Temporal temperature upgrade kit 863342 IntelliVue Guardian software license 863357 SpO2 FAST to Masimo SET upgrade kit 863343 Premium rollstand has an easy-to-clean molded basket that swivels for easy positioning in tight spaces, and dedicated sections for accessories such as a barcode scanner, cleaning wipes, NBP cuffs, extra disposable temperature covers, and the SpO2 sensor. SureSigns VS4 has tested compatible with Cisco Compatible Extensions, Version 4. Go to www.cisco.com/go/compatibledisclaimer for complete disclaimer. Masimo, SET, and rainbow are registered trademarks of Masimo Corporation. Microstream and Covidien are trademarks of Covidien companies. Welch Allyn is a registered trademark and TemporalScanner is a trademark of Welch Allyn Corporation. Exergen is a registered trademark of Exergen Corporation. All other trademarks are property of their respective owners. ©2016 Koninklijke Philips N.V. All rights are reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication. Trademarks are the property of Koninklijke Philips N.V. or their respective owners. www.philips.com/SureSigns Printed in the Netherlands. 4522 991 18911 * MAY 2016
Source Exif Data:
File Type : HTML File Type Extension : html MIME Type : text/html Title : Object movedEXIF Metadata provided by EXIF.tools