Philips MNT80 GCX Mounting Assembly Installation Guide User Manual Product Brochure Intelli Vue MX500 And MX550 Solution Db4640d3411c4dfc9b95a77c0159059f
MNT80 Installation Guide for AG-0018-21 HCMNT80%2DInstallation%2DNote%2Dfor%2DAG%2D0018%2D21 Philips IntelliVue MX400/MX450/MX500/MX550 GCX Variable Height and Pivot Arm Wall Mount Mounting solutionMNT80
MNT59 Installation Note for AG-0018-21 HCMNT59%2DInstallation%2DNote%2Dfor%2DAG%2D0018%2D21 IntelliVue MX500 and MX550 GCX Variable Height and Pivot Arm Wall Mounts Mounting solutionMNT59
MNT72 Installation Note for AG-0018-01 HCMNT72%2DInstallation%2DNote%2Dfor%2DAG%2D0018%2D01 IntelliVue MX500/MX550 Dräger Narkomed 6000 Anesthesia Machine Mounting solutionMNT72
User Manual: Philips MNT80 Product Brochure Philips IntelliVue MX500 and MX550 Mounting solution Philips - Philips IntelliVue MX400/MX450/MX500/MX550 - HCMNT80MNT80
Open the PDF directly: View PDF
.
Page Count: 5
| Download | |
| Open PDF In Browser | View PDF |
3875 Cypress Drive Petaluma, CA 94954 800.228.2555 707.773.1100 Fax 707.773.1180 www.gcx.com Installation Guide Philips IntelliVue MP5/20/30/40/50/60/70, MX400/450/500/550/600/700/800 M-Series Arm Wall Mount Kit The purpose of this guide is to: 1. Describe attachment of Table Mount to Mounting Adapter. 2. Describe attachment of Down Post to Arm. 3. Describe mounting of Arm in Wall Channel. 4. Describe Mounting the Monitor on the Arm. 5. Describe attachment of Flexible Module Server (FMS) to Down Post. 6. Describe operation and adjustment of M-Series Arm. Parts Reference The following parts and hardware are included for this installation procedure (see photos for parts; hardware not shown). Item # Description Qty 1 M-Series Arm with Mounting Adapter 1 2 6'' Down Post Kit 1 3 #10-32 x 3/8'' Socket Head Cap Screw 3 4 M6 x 8mm Flat Head Machine Screw (FHMS) 2 5 M6 x 12mm FHMS 1 6 Adjustable Stop 1 7 5/32'' Hex Wrench 1 8 1/8'' Hex Wrench 1 9 Channel Cover, 16'' 1 *10 Spacer 1 *11 M6 x 16mm Pan Head Machine Screw (PHMS) 2 1 2 10 Table Mount (Supplied by Philips) *See "Non-Table Mount" at the bottom of page 3 for use of these parts. Tools Required: Phillips screwdriver (not provided), 5/32'' and 1/8'' hex wrenches (provided). Caution - Before mounting the Arm: 1. Verify that the Channel has been installed and approved in accordance with the Channel Installation guides. 2. Ensure that the weight of the device being mounted does not exceed the load rating of your M-Series Arm. Check the "Max Load" rating label located on top of the arm at the Slide pivot point. It is not recommended that this arm be used for weights outside of this range. 3. If assistance is needed regarding an application, please contact a GCX product specialist at (800) 228-2555. DU-AG-0018-21 Rev F 12/11/13 GCX Corp Page 1 of 5 Attaching the Philips Table Mount to the Mounting Adapter Installation Note: Do not attach the Table Mount to the Arm/Mounting Adapter if you will be mounting a monitor equipped with the mounting interface shown in photo (right). See "Mounting the Monitor on the Arm" (page 3) for instructions specific to this type of mounting plate. Do not attach Table Mount if Monitor is equipped with this mounting interface. 1. Fasten the Philips-supplied Table Mount to the Mounting Adapter with one (1) M6 x 12mm FHMS and two (2) M6 x 8mm FHMS (see below). M6 X 8mm FHMS (2) M6 X 12mm FHMS (1) Table Mount *Supplied by Philips Mounting Adapter Attaching the Down Post to the Arm Installation Note: The Down Post is used for mounting the Flexible Module Server (FMS). Skip this procedure if your IntelliVue monitoring system does not require a Down Post or FMS. 1. Align the three (3) mounting holes in the Lower Post Disc with the three (3) threaded holes in the Swivel Cup. 2. Using the 5/32'' hex wrench, fasten Post to Swivel Cup with three (3) #10-32 x 3/8'' SHCS. #10-32 x 3/8'' SHCS (3) Swivel Cup Lower Post Disc 6'' Down Post DU-AG-0018-21 Rev F 12/11/13 GCX Corp Page 2 of 5 Mounting the M-Series Arm in the Wall Channel 1. Insert the Adjustable Stop in the top opening of the wall channel and slide it to the bottom of the channel. Secure the Adjustable Stop in the channel by tightening the screw in the center of the Stop. Adjustable Stop 2. While supporting the bottom of the Arm, guide the Slide (at rear of Arm) into the top of the wall channel. Slide the Arm to the desired position in the channel and tighten two (2) set screws (bottom of the Slide) using the 1/8'' key. Slide Set Screws (2) Mounting the Monitor on the Arm Table Mount Mount the monitor in accordance with the Philips Table Mount instruction sheet. Non-Table Mount 1. Fit Spacer into recessed area on top of Mounting Adapter (below). Ensure Spacer remains between Mounting Adapter and monitor. 2. Insert two (2) M6 x 16mm PHMS through bottom of Mounting Adapter and thread into mounting holes in bottom of monitor (right). Spacer Mounting Adapter Spacer M6 x 16 mm PHMS (2) Mounting the MX400/450/500/550 Monitor (Fixed Mount Adapter) Mount the monitor in accordance with separate Installation Guide DU-PH-0073-15 provided with the Mounting Adapter, ordered separately. DU-AG-0018-21 Rev F 12/11/13 GCX Corp Page 3 of 5 Mounting the Flexible Module Server (FMS) on the Down Post Installation Note: This procedure is not applicable unless Down Post has been installed. 1. Mount the FMS on the Down Post by placing the Clamp around the Down Post and tightening the knob. FMS Clamp Down Post Installing the Wall Channel Cover Install the Wall Channel Cover in accordance with the Channel Cover Installation Guide (DU-UT-0001-20). M-Series Arm Operation and Adjustment Positioning Arm in Channel WARNING: Do not attempt to remove the Arm from the Channel while an instrument is mounted. 1. While *supporting the weight of the mounted instrument, loosen the two (2) socket head set screws (SHSS) in the Slide. A 1/8'' hex key is provided for this task. 2. Push up or pull down at the end of the arm nearest the Slide. Tighten the set screws to secure the Arm in the Channel * It may be necessary to dismount the instrument before adjusting the Arm in the Channel. Socket Head Set Screws (2) Swiveling the Mounted Instrument and Adjusting Swivel Tension 1. To swivel the mounted instrument simply push or pull the corners of the instrument. 2. To adjust swivel tension, tighten or loosen the Swivel Tension Nut using a 1/2'' [13 mm] socket wrench or nut driver. Swivel Tension Nut DU-AG-0018-21 Rev F 12/11/13 GCX Corp Page 4 of 5 Tilting the Mounted Instrument Installation Note: Shown without mounted device for detail purposes. 1. To tilt the instrument, grasp the top and bottom of the instrument and tilt it to the desired angle. Tilt Tension Screws (2) 2. To adjust tilt tension, equally tighten or loosen the two (2) Tilt Tension Adjustment screws using the 5/32'' hex wrench provided. Pivoting the Arm and Adjusting Pivot Tension 1. To pivot the Arm at the Slide, simply push on the side of the Arm or mounted instrument. 2. To adjust pivot tension, loosen or tighten the Pivot Tension Bolt using a 1/2" [13 mm] socket driver. Cable Management Two cable management features allow convenient placement and flow of cables: 1. An open cavity beneath the arm (with flexible cable covers) allows management of cables between the front and rear of the arm. Flexible Cable Covers 2. A “pass-through” channel at the rear of the slide allows cables to pass behind the arm within the Channel. Pivot Tension Bolt Installation Note: If cable connectors are too large to fit through the pass-through, try placing the cables in the "pass-through" before installing the arm in the Channel. Pass-through Slide Routine Maintenance Periodically inspect all tilting, swiveling, pivoting, and mounting hardware. Tighten as necessary for optimal operation and safety. Cleaning the Mounting Assembly 1. The mounting assembly may be cleaned with most mild, non-abrasive solutions commonly used in the hospital environment (e.g. diluted bleach, ammonia, or alcohol solutions). 2. The surface finish will be permanently damaged by strong chemicals and solvents such as acetone and trichloroethylene. 3. Do not use steel wool or other abrasive material to clean the mounting assembly. 4. Damage caused by the use of unapproved substances or processes will not be covered by warranty. We recommend testing of any cleaning solution on a small area of the arm that is not visible to verify compatibility. 5. Do not submerge or allow liquids to enter the arm. Wipe any cleaning agents off of the arm immediately using a waterdampened cloth. Dry the arm thoroughly after cleaning. CAUTION: GCX makes no claims regarding the efficacy of the listed chemicals or processes as a means for controlling infection. Consult your hospital’s infection control officer or epidemiologist. To clean or sterilize mounted instruments or accessory equipment, refer to the specific instructions delivered with those products. DU-AG-0018-21 Rev F 12/11/13 GCX Corp Page 5 of 5
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : No Page Count : 5 Language : en-US Tagged PDF : Yes Title : GCX Mounting Assembly Installation Guide Author : Sean Creator : Microsoft® Word 2010 Create Date : 2013:12:11 15:12:54-08:00 Modify Date : 2013:12:11 15:12:54-08:00 Producer : Microsoft® Word 2010EXIF Metadata provided by EXIF.tools