Philips NOCTN333 452299123691 User Manual Product Brochure Intelli Bridge System Patient Care Device Connectivity And Interoperability Solution 3a4fa6438b04487b8b81a77c014983d6
User Manual: Philips NOCTN333 Product Brochure Philips IntelliBridge System Patient care device connectivity and interoperability solution Philips - IntelliBridge SystemNOCTN333
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
IntelliBridge System Making clever connections When comprehensive information is your target, interoperability is your tactic The print quality of this copy is not an accurate representation of the original. Vendor-neutral interoperability between your hospital information systems and patient care devices can both enhance the efficiency of your clinical workflow, and let you leverage patient data to inform clinical decisions. Whether the sources are ventilators, infusion pumps, anesthesia machines, or other equipment – from Philips or other manufacturers – IntelliBridge System can provide the hardware and software to make connections possible. It captures data from a broad range of devices, and translates it to HL7 format for upload to an electronic medical record. This reduces the need for manual data entry, and may enhance the accuracy of medical records. The result can also go beyond just documentation. IntelliBridge System also supports gathering alarm and alert information from the patient care devices connected to it, and transferring it to the Patient Information Center iX (PIC iX). Through the PIC iX and the mobility solutions that integrate with it, such as CareEvent, this information can then be further distributed. This helps caregivers make informed decisions, even when they are not at the bedside, and is what makes IntelliBridge System a leading interoperability solutions for medical devices. Key benefits • IHE-compliant, vendor-neutral interoperability between your hospital information systems and various patient care devices • Conversion of parameter units for consistent documentation across devices • Automatic association of patients with devices (using the PIC iX ADT interface) • Inclusion of alarm information into PIC iX and Philips mobility solutions The print quality of this copy is not an accurate representation of the original. Components IntelliBridge System consists of hardware, and of software components. Patient care devices • Standalone patient monitoring • Respiratory care • Anesthesia delivery • Hemodialysis • Infusion • Infant thermal care • ECLS/ECMO • ... The IntelliBridge EC40 (4 data ports) or EC80 Hub (8 data ports) detects the device, and selects the right interface to capture its Medical Data Interface Language (MDIL) data. The hub then passes the data on to the IntelliBridge Device Interfacing Engine. CAT5 cable (RJ-45 connectors) For patient care devices without a direct connection to the hospital LAN, the IntelliBridge EC5 Device ID Module connects to the serial port (RS-232). The module provides unique identification information to make the device “plug and play”. 10/100/1000 Mbps Ethernet connection to the hospital LAN • The IntelliBridge Device Interfacing Engine runs on a Philips-supplied host computer, a virtual server, or the PIC iX. The device interfacing engine collects data from patient care devices either connected through IntelliBridge hubs or directly to it over the LAN. It both maintains a database of the data it aggregates and translates the data into HL7 format, which it sends to hospital information systems. • The IntelliBridge Management Console is a web application that runs with the device interfacing engine, to give support personnel a way of configuring and troubleshooting the IntelliBridge System from a browser. • View status of the hubs and connected patient care devices. • Install patient care device interfaces and firmware on the hubs. • Define parameter unit conversions. Network Recommendations We recommend running IntelliBridge System on a dedicated VLAN, to avoid conflicts with other devices. Multiple IntelliBridge Systems can run on the same VLAN, if necessary. The print quality of this copy is not an accurate representation of the original. Features and benefits Connectivity for a broad selection of patient care devices IntelliBridge System provides device interfaces for many popular patient care devices (for a full, current list refer to the IntelliBridge Device Interface Library). We collaborate with leading medical device manufacturers to continually develop interfaces as new devices are introduced, as well as to keep existing interfaces up-to-date. And many medical device manufacturers – including companies with devices for niche applications – develop their own interfaces, using our IntelliBridge Open Interface protocol. Compliance to IHE HL7 The Integrating the Healthcare Enterprise (IHE) initiative aims to establish standards for healthcare interoperability. Because Philips is an active member and key contributor to the initiative, IntelliBridge System uses an HL7 format that complies with several IHE profiles, making integration and maintenance easy. These profiles include • In the IHE Patient Care Device (PCD) domain o Alert Communication Management (ACM) profile o Device Enterprise Communication (DEC) profile • In the IHE IT Infrastructure Technical Framework o Patient Administration Management (PAM) profile. Converting parameter units Different healthcare organizations use different units for patient parameter data. For example, one site may document volumes in liters while another prefers milliliters. IntelliBridge System lets users specify which units to use for which parameters, and converts these for the HL7 output. IntelliBridge System applies the conversion globally for each specified parameter. This means that even if several patient care devices use different units for the same parameter, the HL7 data sent to the electronic medical record is consistent. If you are using a Patient Information Center iX (PIC iX) • To help you achieve more comprehensive and accurate patient records, IntelliBridge System can use the PIC iX ADT interface. This lets it automatically associate patient demographic information with the data from the patient care device. • To help caregivers make informed decisions, IntelliBridge System can distribute alarm or alert notifications and integrate with the PIC iX alarm management tools. This makes it possible for IntelliBridge System to distribute alarms from patient care devices to mobility solutions, such as CareEvent. The print quality of this copy is not an accurate representation of the original. The print quality of this copy is not an accurate representation of the original. Specifications IntelliBridge EC5 IntelliBridge E40/EC80 17 × 35 × 57 mm (0.67 × 1.38 × 2.24 in) With mounting bracket: 200 × 200 × 75 mm (7.87 × 7.87 × 2.95 in) Physical Dimensions (H × W × D) Without mounting bracket: 200 × 200 × 87 mm (7.87 × 7.87 × 3.43 in) Weight 35 g (1.23 oz) 1.4 kg (3.09 lb) N/A 100 to 240 VAC (auto sensing), 1A, 50 to 60 Hz Operating temperature -5 to 50°C (23 to 122°F) 0 to 55°C (32 to 131°F) Operating humidity 15 to 95% RH at 45°C (113°F) Up to 95% RH at 40°C (104°F) Operating altitude -457 to 4,572 m (-1500 to 15,000 ft) Up to 3,048 m (10,000 ft) Storage temperature -40 to 70°C (-40 to 158°F) -40 to 60°C (-40 to 140°F) Storage humidity Up to 90% RH at 65°C (149°F) Up to 90% RH at 60°C (140°F) Storage altitude -457 to 15,240 m (-1500 to 50,000 ft) Up to 3,048 m (10,000 ft) Electrical Input power Environmental Compliance EN 60601-1:1990+A1:1993+A2:1995 IEC 60601-1:1988+A1:1991+A2:1995 EN 60601-1-1:2001/IEC 60601-1-1:2000 UL 60601-1:2003 CAN/CSA C22.2#601.1-M90:1990 AS/NZS 3200.1.0-1998 EN/IEC 60601-2-49:2001 Safety • • • • • • • Electromagnetic compatibility EN/IEC 60601-1-2:2001 The print quality of this copy is not an accurate representation of the original. • • • • • • • • IEC 601-1 + Am. 1 + Am.2 + Corr. EN60601-1: 1991/A2:1995 IEC 60601-1-4: 1996/A1:1999 EN60601-1-4: 1996/A1:1999 For Canada: CSA C22.2 No. 601.1- M90 (2005) For U.S.: UL 60601-1, First Edition CE marking to Council Directive 93/42/EEC CSA marking to applicable Canadian and U.S. standards EN/IEC 60601-1-2:2001 About the Philips IntelliBridge solution Philips has a proven track record of providing patient device connectivity for a broad selection of Philips and third-party patient care devices since we introduced the VueLink Interface Module in 1992. The IntelliBridge family of connectivity solutions – IntelliBridge Bedside, IntelliBridge System, and IntelliBridge Enterprise - continues this commitment to addressing the need for automated data capture and documentation, and end-to-end alarm management and alert notification. The print quality of this copy is not an accurate representation of the original. © 2016 Koninklijke Philips N.V. All rights reserved. Specifications are subject to change without notice. www.philips.com 4522 991 23691 * DEC 2016 The print quality of this copy is not an accurate representation of the original.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : Yes Encryption : Standard V2.3 (128-bit) User Access : Print, Copy, Annotate, Fill forms, Extract, Print high-res Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c015 81.157285, 2014/12/12-00:43:15 Create Date : 2016:12:15 13:53:11+01:00 Metadata Date : 2017:01:18 10:07:16-05:00 Modify Date : 2017:01:18 10:07:16-05:00 Creator Tool : Adobe InDesign CC 2017 (Macintosh) Instance ID : uuid:a3c95dc3-5dfb-4941-a04d-d0db91dd18b5 Original Document ID : adobe:docid:indd:b1ddd603-51ee-11db-b025-8168767f4149 Document ID : xmp.id:aa672529-0edb-4a2e-a32c-d9769c78cdd9 Rendition Class : proof:pdf Version ID : 1 Derived From Instance ID : xmp.iid:7e1accaa-07bb-4647-aff5-6148a7474bca Derived From Document ID : xmp.did:40d8493c-752b-43a7-a9c5-d00ae3ced214 Derived From Original Document ID: adobe:docid:indd:b1ddd603-51ee-11db-b025-8168767f4149 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2017 (Macintosh) History Changed : / History When : 2016:12:15 13:53:11+01:00 Format : application/pdf Title : 452299123691.indd Producer : Adobe PDF Library 15.0 Trapped : False GTS PDFX Version : PDF/X-1:2001 GTS PDFX Conformance : PDF/X-1a:2001 Page Count : 8 Creator : Adobe InDesign CC 2017 (Macintosh)EXIF Metadata provided by EXIF.tools