Pilz and KG PSENSG RFID Proximity switch with guard locking User Manual BA PSENsgate2
Pilz GmbH & Co. KG RFID Proximity switch with guard locking BA PSENsgate2
Contents
- 1. Manual part1
- 2. Manual part2
Manual part1
PSEN sg2c PSEN sensor technology Operating Manual1003267EN02 Preface This document is a translation of the original document. All rights to this documentation are reserved by Pilz GmbH & Co. KG. Copies may be made for internal purposes. Suggestions and comments for improving this documentation will be gratefully received. Pilz®, PIT®, PMI®, PNOZ®, Primo®, PSEN®, PSS®, PVIS®, SafetyBUS p®, SafetyEYE®, SafetyNET p®, the spirit of safety® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. SD means Secure Digital Content Section 1 Introduction 1.1 Validity of documentation 1.2 Retaining the documentation 1.3 Definition of symbols Section 2 Overview 2.1 Scope of supply 2.2 Unit features Section 3 Safety 3.1 3.2 3.2.1 3.2.2 3.2.3 3.3 Intended use Safety regulations Use of qualified personnel Warranty and liability Disposal For your safety Section 4 Function description 4.1 Normal /Unlock mode 4.2 Escape release 4.3 Auxiliary release 4.4 Pushbutton 4.5 Device types 4.6 Block diagram 10 10 11 12 13 14 18 Section 5 Wiring 5.1 5.2 5.3 5.4 5.5 5.6 5.7 5.8 5.9 5.9.1 5.9.2 5.10 5.11 19 19 20 20 21 22 23 23 23 24 24 24 25 25 Section 6 Notes on cable run Recommended cable cross sections General wiring guidelines Terminal configuration Wiring the connection terminals ESTOP pushbutton connection Enabling switch connection EMC requirements Connection to evaluation devices Connection examples PNOZmulti Connection examples PSS Single connection Series connection Installation 6.1 Install at profile 6.2 Initial installation safety switch and handle unit 6.3 Second installation of safety switch and handle unit / upgrade for left hinged gates 6.4 Inscription of buttons 6.5 Dimensions in mm 6.5.1 Drill holes Operating Manual PSEN sg2c 1003267EN02 28 29 33 34 35 35 35 Content 6.5.2 6.5.3 6.5.4 PSEN sg2c3xxx PSEN sg2c5xxxxx PSEN sg2c5xxxxxM12/5 36 37 38 Section 7 Adjustment 39 Section 8 Maintenance 40 Section 9 Operation 9.1 Status table 9.2 Normal mode and Unlock mode 9.3 Remedy 41 42 43 44 Section 10 Technical Details Order No. 570800570804 46 Section 11 Technical Details Order No. 570806570810 50 Section 12 Technical Details Order No. 570812570816 54 Section 13 Technical Details Order No. 570818570822 58 Section 14 Technical Details Order No. 570824570828 62 Section 15 Technical Details Order No. 570830570834 66 Section 16 Technical Details Order No. 570880570884 70 Section 17 Safety characteristic data 74 Section 18 Order reference 18.1 System 18.2 Safety switch 18.3 Handle unit with actuator 18.4 Accessories 75 75 76 77 77 Section 19 EC Declaration of Conformity 78 Operating Manual PSEN sg2c 1003267EN02 Introduction Introduction 1.1 Validity of documentation This documentation is valid for the product PSENsg2c. It is valid until new documentation is published. This operating manual explains the function and operation, describes the installation and provides guidelines on how to connect the product. 1.2 Retaining the documentation This documentation is intended for instruction and should be retained for future reference. 1.3 Definition of symbols Information that is particularly important is identified as follows: DANGER! This warning must be heeded! It warns of a hazardous situation that poses an immediate threat of serious injury and death and indicates preventive measures that can be taken. WARNING! This warning must be heeded! It warns of a hazardous situation that could lead to serious injury and death and indicates preventive measures that can be taken. CAUTION! This refers to a hazard that can lead to a less serious or minor injury plus material damage, and also provides information on preventive measures that can be taken. NOTICE This describes a situation in which the product or devices could be dam aged and also provides information on preventive measures that can be taken. It also highlights areas within the text that are of particular import ance. Operating Manual PSEN sg2c 1003267EN02 Introduction INFORMATION This gives advice on applications and provides information on special fea tures. Operating Manual PSEN sg2c 1003267EN02 Overview Overview 2.1 Scope of supply 2.2 Safety switch Handle unit Colour covers for illuminated buttons Pin for escape release Pin for auxiliary release Unit features Safe guard locking (only for revolving gates and swing gates) Safe interlocking (position monitoring) Transponder technology 2 safety inputs for series connection of multiple safety switches 2 safety outputs Guard locking element keeps the safety gate from being opened unintentionally Detection of broken bolt tongue and broken guard locking element Bolt tongue with drill holes to attach padlocks as a restart interlock Auxiliary release for opening the safety gate, when the plant's voltage is switched off Escape release for fast manual release of the guard locking in emergency situations from within the danger zone (revolving gates and swing gates) Suitable for left and right hinged safety gates Note: The handle unit PSEN sg1 actuator is only suitable for revolving gates and swing gates. Plugin springloaded terminals LED display for: – Supply voltage/fault – Gate closed – State of the hazardous machine – Request to stop the machine – State of the inputs – Bolt tongue engaged Depends on device type – various pushbuttons, as for example integral ESTOP pushbutton, section stop pushbutton, key switch... – Full coding/coding see Chapter Device types Operating Manual PSEN sg2c 1003267EN02 Safety Safety 3.1 Intended use The safety gate system is used for guard locking and interlocking swing gates and revolving gates. It meets the requirements in accordance with: EN 602041 EN 6094753 EN 62061: SIL CL 3 EN ISO 138491: Up to PL e (Cat. 4) EN 1088 EN ISO 14119 The safety level PL e (Cat. 4)/SIL CL 3 can only be achieved when The safety outputs use 2channel processing and The solenoid is operated 2channel via safe relay outputs, suitable for PL e (Cat. 4)/SIL CL 3 applications. Wiring errors should also be excluded using appropriate measures. The potential solutions are the protected cable layout or the use of pulsed semicon ductor outputs. 3.2 Safety regulations 3.2.1 Use of qualified personnel The products may only be assembled, installed, programmed, commissioned, operated, maintained and decommissioned by competent persons. A competent person is someone who, because of their training, experience and current pro fessional activity, has the specialist knowledge required to test, assess and operate the work equipment, devices, systems, plant and machinery in accordance with the general standards and guidelines for safety technology. It is the company’s responsibility only to employ personnel who: 3.2.2 Are familiar with the basic regulations concerning health and safety / accident preven tion Have read and understood the information provided in this description under "Safety" And have a good knowledge of the generic and specialist standards applicable to the specific application. Warranty and liability All claims to warranty and liability will be rendered invalid if The product was used contrary to the purpose for which it is intended Damage can be attributed to not having followed the guidelines in the manual Operating personnel are not suitably qualified Operating Manual PSEN sg2c 1003267EN02 Safety 3.2.3 3.3 Any type of modification has been made (e.g. exchanging components on the PCB boards, soldering work etc.). Disposal In safetyrelated applications, please comply with the mission time tM in the safetyre lated characteristic data. When decommissioning, please comply with local regulations regarding the disposal of electronic devices (e.g. Electrical and Electronic Equipment Act). For your safety WARNING! Potential loss of safety function during adjustment and repair work! When carrying out adjustment and repair work, make sure that the power supply of the plant is switched off and protected against switching on again. WARNING! Loss of safety function due to manipulative use of substitute actuating ele ments! When substitute actuating elements are used, these have to be installed as described in chapter Install at profile [ 29]. When substitute actuating elements are used in a manipulative way to defeat the protective device, op erating the plant presents a threat to life. The operator has to consider this in the hazard analysis and he must de termine possible countermeasures. Operating Manual PSEN sg2c 1003267EN02 Function description Function description The interlocking and guard locking system prevents the safety gates to the danger zone from opening while the hazardous machine is switched on. There is a high signal (safety gate closed and locked) at safety outputs X13 and X14 if the following conditions are met simultaneously: Inputs X23 and X24 are high and The bolt tongue is within the response range and The guard locking element is engaged in the bolt tongue and The escape or auxiliary release pin is in the correct position. Signal output X19 is high if: The bolt tongue is within the response rang There is a low signal (safety gate open and hazardous machine function interlocked) at safety outputs X13 and X14 if the following occurs: Inputs X23 or X24 are low or The guard locking element is outside the bolt tongue or The escape or auxiliary release has been operated If the safety outputs have been shut down by either of the inputs X23 or X24, they cannot be switched back on until both inputs are low simultaneously. A High signal has to be present at X16 (X26) and a Low signal at X17 (X27) for operat ing the solenoid after the hazardous movement has been ended. 4.1 Normal /Unlock mode Normal mode: The safety gate to the danger zone is not unlocked until the hazardous machine is stopped and the pushbutton for access request has been operated. The guard locking element is disengaged from the bolt tongue as soon as there is a high signal at terminals X16 and X17 or X26 and X27, followed by operation of the pushbutton for access request. Unlock mode: The safety gate to the danger zone is unlocked when the hazardous machine is stopped. This enables easier access for cleaning staff once the shift has ended, for example. The guard locking element is disengaged from the bolt tongue as soon as there is a high signal at terminals X16 and X17 or X26 and X27. Operating Manual PSEN sg2c 1003267EN02 10 Function description 4.2 Escape release The escape release enables the guard locking to be manually released from within the danger zone. (2) (4) (3) (1) Mode of operation Within the danger zone, if the escape release pin (1) is pressed in the direction of the safety gate, the cover on the escape release (2) is removed and the swivel piece (3) folds down wards. The bolt tongue (4) behind the swivel piece is released. The safety gate can be opened immediately, enabling the operator to leave the danger zone. The escape release pin must only be accessible from the inside of the danger zone. The escape release must be regularly inspected and cleaned, as described in the chapter Maintenance [ Operating Manual PSEN sg2c 1003267EN02 40]. 11 Function description INFORMATION When the escape or auxiliary release is operated, there is a low signal at the safety outputs X13 and X14. An error code is issued. The PSENsgate is not ready for operation again until the escape release or auxiliary release has been reset to its unoperated state and the error has been reset. Please note that the cover of the escape release has to be checked and in stalled again after operation. 4.3 Auxiliary release When the plant is powered down, the auxiliary release enables the guard locking device to be released from the access side to the danger zone. (1) (2) (4) (3) Mode of operation: Carefully remove the cover on the escape release (1). Use a screwdriver (2) to pull out the escape or auxiliary release pin (3) from the swivel piece (4). The swivel piece folds down wards, the bolt tongue behind the swivel piece is released. The safety gate to the danger zone can be opened. Operating Manual PSEN sg2c 1003267EN02 12 Function description INFORMATION When the escape or auxiliary release is operated, there is a low signal at the safety outputs X13 and X14. An error code is issued. The PSENsgate is not ready for operation again until the escape release or auxiliary release has been reset to its unoperated state and the error has been reset. Please note that the cover of the escape release has to be checked and in stalled again after operation. 4.4 Pushbutton Pushbutton 4 Pushbutton 3 Pushbutton 2 Pushbutton 2 Pushbutton 1 Pushbutton 1 PSEN sg2c-3... PSEN sg2c-5... Pushbutton 1: Pushbutton for activating the guard locking of the safety gate Pressing the pushbutton for activating the interlock engages the guard locking element into the bolt tongue. Pushbutton 2: Pushbutton for access request and release of the safety gate – Pressing the pushbutton for access request disengages the guard locking element from the bolt tongue when a high signal is present at X16 and X17 or at X26 and X27 (solenoid operation). – Pressing the pushbutton for access request switches output X15 (access request) when a low signal is present at X16 and X17 or at X26 and X27 (solenoid opera tion). Operating Manual PSEN sg2c 1003267EN02 13 Function description Depending on the design, the device also has: Emergency stop or section stop pushbutton Pushbutton 3 and pushbutton 4 Pushbuttons that can be used depending on the application: – Operating a pushbutton switches the pushbutton output – The LEDs of the pushbuttons can be operated via the LED inputs. Further information on the different types of text is can be found in chapter Device types [ 14]. 4.5 Device types 21 different versions are available. They differ in number and quality of the pushbuttons basic coding of full coding M12 connection for enabling switch or no connection [6] [5] [5] [4] [4] [3] [3] [3] [2] [2] [2] [1] [1] [1] PSEN sg2c-3xxx Operating Manual PSEN sg2c 1003267EN02 PSEN sg2c-5xxxxx PSEN sg2c-5xxxxx-M12/5 14 Function description PSEN sg2c3xxx (3 pushbuttons) [1] pushbutton 1: Pushbutton for activating the guard locking of the safety gate [2] pushbutton 2: Pushbutton for access request and release of the safety gate [3] ESTOP/ or section stop Name key: [1] [2] [3] PSEN sg2c - 3 L X X 2.2* 3 pushbuttons = 3 Pushbutton illuminated = L Pushbutton unilluminated = P Key switch = B E-STOP = E Section stop = S no pushbutton = C Fully-coded *not included with all versions Versions: Pushbutton 1 Pushbutton 2 ESTOP/ Section stop Coding 3LPE Pushbutton illuminated Pushbutton unilluminated ESTOP coded 3LBE Pushbutton illuminated Key switch ESTOP coded 3LPS Pushbutton illuminated Pushbutton unilluminated Section stop coded 3LBS Pushbutton illuminated Key switch Section stop coded 3LPC Pushbutton illuminated Pushbutton unilluminated coded 3LBC Pushbutton illuminated Key switch coded 3LPE 2.2 Pushbutton illuminated Pushbutton unilluminated ESTOP fully coded Operating Manual PSEN sg2c 1003267EN02 15 Function description PSEN sg2c5xxxxx and PSEN sg2c5xxxxxM12 (5 pushbuttons): [1] pushbutton 1: Pushbutton for activating the guard locking of the safety gate [2] pushbutton 2: Pushbutton for access request and release of the safety gate [3], [4] pushbuttons 3 4: can be used depending on the application [5] ESTOP/ or section stop [6] M12 connection for enabling switch Name key: [1] [2] [3] [4] [5] [6] PSEN sg2c - 5 L X X L X - M12/5* 2.2* 5 pushbuttons = 5 Pushbutton illuminated = L Pushbutton unilluminated = P Key switch = B Pushbutton illuminated = L Key switch = B Pushbutton illuminated = L E-STOP = E Section stop = S no pushbutton = C Enabling switch Fully-coded Fig.: *not included with all versions Versions: Pushbut Pushbut Pushbut Pushbut ESTOP/ ton 1 ton 2 ton 3 ton 4 Section stop M12 Coding 5LPLLE Pushbut Pushbut Pushbut ton ton ton illumin unillumin illumin ated ated ated Pushbut ton illumin ated ESTOP coded 5LBLLE Pushbut ton illumin ated Pushbut ton illumin ated Pushbut ton illumin ated ESTOP coded 5LPLLS Pushbut Pushbut Pushbut ton ton ton illumin unillumin illumin ated ated ated Pushbut ton illumin ated Section stop coded Operating Manual PSEN sg2c 1003267EN02 Key switch 16 Function description 5LBLLS Pushbut ton illumin ated Pushbut ton illumin ated Pushbut ton illumin ated Section stop coded 5LPLLC Pushbut Pushbut Pushbut ton ton ton illumin unillumin illumin ated ated ated Pushbut ton illumin ated coded 5LBLLC Pushbut ton illumin ated Pushbut ton illumin ated Pushbut ton illumin ated coded 5LPKLE M12/5 Pushbut Pushbut ton ton illumin unillumin ated ated Key switch Pushbut ton illumin ated ESTOP Yes coded 5LBKLE M12/5 Pushbut ton illumin ated Key switch Pushbut ton illumin ated ESTOP Yes coded 5LPKLS M12/5 Pushbut Pushbut ton ton illumin unillumin ated ated Key switch Pushbut ton illumin ated Section stop Yes coded 5LBKLS M12/5 Pushbut ton illumin ated Key switch Pushbut ton illumin ated Section stop Yes coded 5LPKLC M12/5 Pushbut Pushbut ton ton illumin unillumin ated ated Key switch Pushbut ton illumin ated coded Key switch Pushbut ton illumin ated Yes coded 5LBKLC Pushbut M12/5 ton illumin ated Key switch Key switch Key switch Key switch Key switch 5LPLLE 2.2 Pushbut Pushbut Pushbut ton ton ton illumin unillumin illumin ated ated ated Pushbut ton illumin ated ESTOP fully coded 5LPKLE M12/5 2.2 Pushbut Pushbut ton ton illumin unillumin ated ated Pushbut ton illumin ated ESTOP Yes fully coded Operating Manual PSEN sg2c 1003267EN02 Key switch 17 Function description Block diagram 4.6 24 V Operating Manual PSEN sg2c 1003267EN02 18 Wiring Wiring 5.1 Notes on cable run The maximum cable run depends on the voltage drop in the supply voltage conductors for solenoid operation. The level of voltage drop is determined by the cable resistance of the cables solenoid current of the solenoid If the voltage drop in the supply voltage conductors becomes too high, the voltage for solenoid operation can permanently be set to the upper tolerance range (see Technical de tails). The max. conductor cross section is 10 mm. Example: Connecting 3 safety switches in series Total cable run: 25 m Conductor cross section: 0.5 mm2 Solenoid current per solenoid: 1.5 A Voltage for solenoid operation: 24 V Cable impedence(2x0.25 mm²) =0.05 Ohm/meter U~0.05*10*1.5*4.5~3.4 V U~0.05*5*1.5*3~1.1 V U~0.05*10*1.5*1.5~1.5 V U~cable specific impedence*cable length*cable factor*current The voltage drop over all the safety switches is 6 V. This means, there are only 18.0 V at the terminals of the last solenoid. The solenoid is no longer operated reliably. If the voltage for operating the solenoid is increased by the max. permitted tolerance to 26.4, there are still 20.4 V at the terminals of the last solenoid. The solenoid switches reliably. Operating Manual PSEN sg2c 1003267EN02 19 Wiring 5.2 Recommended cable cross sections The values in the table are valid for a series connection with max. 3 sensors and a voltage for solenoid operation of 24 V. The solenoid current is 1.5 A per solenoid. For differing values the conductor cross section must be calculated. 1 safety switches 2 safety switches 3 safety switches 0.25 mm2, AWG24 0.25 mm2, AWG24 0.5 mm2, AWG21 10 0.25 mm2, AWG24 0.25 mm2, AWG24 0.5 mm2, AWG21 15 0.25 mm2, AWG24 0.25 mm2, AWG24 0.5 mm2, AWG21 20 0.25 mm2, AWG24 0.5 mm2, AWG21 25 0.25 mm2, AWG24 0.5 mm2, AWG21 30 0.25 mm , AWG24 40 0.5 mm2, AWG21 Total cable run [m] 50 0.5 mm , AWG21 60 0.5 mm2, AWG21 70 Cable runs marked with an x are not recommended. For operating several safety switches with greater cable runs, the cables for solenoid oper ation (terminals X16 and X17) have to be carried individually, or several cables have to be used. If more than three safety switches are connected in series or cable runs over 60 m are required, please contact Pilz. The permitted conductor cross section is at least 0.25 mm². To have a higher conductor cross section, two cable cores can be inserted into a terminal. This adds together the con ductor cross sections and halves the cable resistances. In this case, use a terminal lug! The signals important for cable resistance are: 5.3 24 V (X11 or X21) 0 V (X12 or X22) the two solenoid operation signals (X16 and X17 or X26 and X27). General wiring guidelines Please note: All metallic surfaces on the safety switch are connected to 0 V via a resistor (100 kOhm) for functional earthing. UL requirements: – Use copper wiring with a temperature stability of 75 *. – Use an LVLC supply (LVLC: limited voltage, limited current). – Use multicore cable with a cable diameter of 6 ... 10 mm. The permitted conductor cross section for the connectors is 0.25 1.0 mm², 23 17 AWG. Operating Manual PSEN sg2c 1003267EN02 20 Wiring 5.4 When calculating the max. cable run, remember to take into account the chapter "Notes on cable run". Terminal configuration 1 3 5 7 9 11 13 15 X1 2 4 6 8 10 12 14 16 1 3 5 7 9 11 13 15 X2 2 4 6 8 10 12 14 16 PSEN sg2c5xxxx PSEN sg2c5xxxx M12/5 X11 X21 linked intern +24 UB ally +24 UB +24 UB X15 X25 linked intern 0 V ally 0V 0V X13 Safety output channel 1 Safety output channel 1 Safety output channel 1 X14 Safety output channel 2 Safety output channel 2 Safety output channel 2 Terminal PSEN sg2c3xxx X15 X25 linked intern Output pushbutton for ac Output pushbutton for ac Output pushbutton for ac ally cess request [2] cess request [2] cess request [2] X16 X26 linked intern Solenoid operation (24 V) Solenoid operation (24 V) Solenoid operation (24 V) ally X17 X27 linked intern Solenoid operation (24 V) Solenoid operation (24 V) Solenoid operation (24 V) ally X18 X28 linked intern Input for activating the ally guard locking of the safety gate Input for activating the guard locking of the safety gate Input for activating the guard locking of the safety gate X19 Signal output for state of the bolt tongue Signal output for state of the bolt tongue Signal output for state of the bolt tongue X110 Emergency stop 1.1 Emergency stop 1.1 Emergency stop 1.1 X111 Emergency stop 1.2 Emergency stop 1.2 Emergency stop 1.2 X112 Emergency stop 2.1 Emergency stop 2.1 Emergency stop 2.1 X113 Emergency stop 2.2 Emergency stop 2.2 Emergency stop 2.2 X114 n.c Pushbutton 3 LED3 n.c X115 n.c Pushbutton 4 LED4 Pushbutton 4 LED4 Operating Manual PSEN sg2c 1003267EN02 21 Wiring PSEN sg2c5xxxx M12/5 Terminal PSEN sg2c3xxx PSEN sg2c5xxxx X116 Signal output ESTOP Signal output ESTOP Enabling switch Pin5 and signal output ESTOP X23 Input, channel 1 Input, channel 1 Input, channel 1 X24 Input, channel 2 Input, channel 2 Input, channel 2 X29 n.c n.c Enabling switch M12 Pin 1 (optional) X210 n.c n.c Enabling switch M12 Pin 2 (optional) X211 n.c n.c Enabling switch M12 Pin 3 (optional) X212 n.c n.c Enabling switch M12 Pin 4 (optional) X213 n.c Pushbutton 3 channel 1 Pushbutton 3 channel 1 X214 n.c n.c Pushbutton 3 channel 2 X215 n.c Pushbutton 4 channel 1 Pushbutton 4 channel 1 X216 n.c n.c n.c 5.5 Wiring the connection terminals Connecting the cables: Use a flat blade screwdriver (DIN 5264A)! DIN 5264-A Strip the wire back 7 mm. Insert the screwdriver into the square hole. Insert the stripped wire into the square hole as far as it will go. Pull out the screwdriver. Check that the cable is firmly seated. Operating Manual PSEN sg2c 1003267EN02 22 Wiring 5.6 ESTOP pushbutton connection CAUTION! With versions with integral ESTOP pushbutton, the ESTOP pushbutton (terminals X110 to X113) must be integrated into the plant/machine's E STOP concept in accordance with EN/IEC 60204. 5.7 Enabling switch connection Details of the pin assignment of the female 5pin M12 connector for the enabling switch can be found in the block diagram and the terminal configuration. We recommend you use the PIT en1.0p5ms (order no. 401 110) as the enabling switch. 5.8 EMC requirements Please note: The power supply must meet the regulations for extra low voltages with protective sep aration (SELV, PELV). The inputs and outputs of the safety switch must have a protective separation to voltages over 60 V AC. The supply voltage has to be at the safety switch terminals within the indicated toler ances (see Technical details). the supply voltage of the safety switch must be secured with a fuse of type quick between 2 A and 10 A. The electrical installation must be performed in accordance with IEC/EN 60204. The assured release distance (SaO) can be influenced by external influences (e.g.: tem perature, dirt, EMC) (see Technical details). Operating Manual PSEN sg2c 1003267EN02 23 Wiring INFORMATION Safety relays with universal power supply or in AC device versions have in ternal potential isolation and are not suitable as evaluation devices. Only safety relays with a 24 V DC supply voltage are suitable. 5.9 Connection to evaluation devices 5.9.1 Connection examples PNOZmulti up to PL c/SIL CL 2 PL e/SIL CL 3 FS O1 FS O1 24 V) 5.9.2 FS O2 24 V) Connection examples PSS up to PL c/SIL CL 2 PL e/SIL CL 3 FS DO O1 FS DO O1 24 V) Operating Manual PSEN sg2c 1003267EN02 FS DO O2 24V) 24 Wiring 5.10 Single connection INFORMATION When the solenoid is operated in singlechannel, only a safety level of PL d (Cat. 2)/SIL CL 2 can be achieved. To achieve PL e (Cat. 4/SIL CL 3, the solenoid must have dualchannel op eration, e. g. via safe pulsed semiconductor outputs with high current load capacity (0.9 A for 50 ms). 24 V X2-3 0V X2-4 PSENsgate X1-1 X1-2 X1-8 X1-7 X1-6 X1-5 X1-9 X1-3 X1-4 O3 (ST) O2 (FS) O1 (FS) I1 (ST) I2 (ST) I3 (FS) I4 (FS) Auswertegerät/ Evaluation device/ Appareil de surveillance/ Dispositivo di controllo A1 A2 FS: Fail-safe ST: Standard 5.11 Series connection CAUTION! Extension of delayon deenergisation When several (n) devices are connected in series, the delayon deener gisation time adds with the number of interconnected safety switches. The may. delayon deenergisation is composed of max. delayon deenergisation actuator + (n1) x max. delayon deenergisation of the inputs + delayon deenergisation of the evaluation device Operating Manual PSEN sg2c 1003267EN02 25 Wiring INFORMATION When the solenoid is operated in singlechannel, only a safety level of PL d (Cat. 2) / SIL CL 2 can be achieved. To achieve PL e (Cat. 4)/SIL CL 3, the solenoid must have dualchannel op eration. For applications with singlechannel operation of the solenoid (up to PL d/SIL CL 2) a safe output with 2 A or a momentarily overloadable safe output (1.8 A for 50 ms) can be used. The device can be switched in series with all safety switches from Pilz. In the connection example the guard locking of safety switches is activated / deactivated via access request (X15). The maximum switching current of the solenoid is present only while switching the solenoids for about 50 ms. The solenoids of the safety switches are switched with a low time offset of ca. 1 s, to avoid power surges at the evaluation device. Operating Manual PSEN sg2c 1003267EN02 26 Wiring 0V 24 V X2-3 X2-4 PSENsgate X1-8 X1-7 X1-2 X1-1 X1-3 X1-4 X1-6 X1-5 X2-8 X2-7 X2-2 X2-1 X2-3 X2-4 X2-5 X2-6 PSENsgate X1-8 X1-7 X1-2 X1-1 X1-3 X1-4 X1-6 X1-5 X2-8 X2-7 X2-2 X2-1 X2-3 X2-4 X2-6 X2-5 PSENsgate X1-9 I1 (ST) X1-9 I2 (ST) X1-9 I3 (ST) X1-5 I4 (ST) PLC X1-2 X1-1 X1-6 O1 (FS) X1-7 O2 (FS) X1-8 X1-3 X1-4 I1 (FS) I2 (FS) O3 (ST) A1 A2 Operating Manual PSEN sg2c 1003267EN02 Auswertegerät/ Evaluation device/ Appareil de surveillance/ Dispositivo di controllo FS: Fail-safe ST: Standard 27 Installation Installation When installing make sure you comply with the requirements of DIN EN 1088. and EN ISO 14119. The safety switch and handle unit should be installed opposite each other in parallel. Safety switch and handle unit should be secured only with socket head cap screws M5 DIN EN ISO 4762. NOTICE It must not be possible to operate or remove the handle unit from inside the danger zone. Protect the handle unit from access, e.g. by covers on the hazard side of the door. INFORMATION The handle unit should be protected from unauthorised removal and from contamination. Safety switch and handle unit Should not be exposed to heavy shock or vibration Should not be used as a limit stop Operating Manual PSEN sg2c 1003267EN02 28 Installation 6.1 Install at profile Open the escape cover in the direction of opening and remove it. Prepare hole 9 mm for the escape release and attach profile nuts to the aluminium pro file (see also Dimensions for the drill holes [ 35]). The escape release does not require a drill hole. Operating Manual PSEN sg2c 1003267EN02 29 Installation Align actuator guide plate and safety switch. Please note the distance between the handle unit and the safety switch (see chapter Adjustment [ 39]). Fix actuator guide plate and safety switch with M5 DIN EN ISO 4762 socket head cap screws (hexagon socket, e.g.: Bossard: BN3 (without shaft), galvanised blue, torque setting MA = 5 Nm). Use washer M5 DIN125A (e.g.: Bossard: BN 715, galvan ised blue, dimension: 10 x 5.3 x 1) for this. The fixing screws on the safety switch are located under the cover of the escape re lease. Use an appropriate screw adhesive (e.g. Loctite 2700) to protect the socket head cap screws from working loose. When using only the unprotected screws [1] that can be reached at the side for in stalling the actuator guide plate, oneway screws have to be used for manipulation pro tection. When using the screws that are protected against manipulation under the bolt tongue [2], this is not necessary. [1] [2] Operating Manual PSEN sg2c 1003267EN02 30 Installation Unscrew the pressure screw from the housing and remove the rubber seal. Thread the cable through the correctly oriented pressure screw and the rubber seal, re move the blind insert if necessary. Remove the countersunk screws at the housing cover for the connection terminals and slowly remove the housing cover. In doing so, the spring mechanism moves the cover of the escape release upwards. Unscrew the plate of the strain relief. Connect and insert connection terminals. Position cable and screw on the strain relief plate (torque setting 0.9 Nm (8 inlbs)). Fix housing cover with screws (torque setting 1.7 +/ 0.1 Nm (15 inlbs)). Move the rubber seal along the cables and position it in the housing. Screw pressure screw on the thread. Operating Manual PSEN sg2c 1003267EN02 31 Installation Insert the escape or auxiliary release pin [1] into the safety switch and push it right to the back. The swivel piece [2] must be maintained in a vertical position, safe from the escape or auxiliary release pin. Screw the ball head on to the escape release pin. Check the escape release for ease of movement. Fold down the cover on the escape release * and lock into position. Screw the ball handle [4] into the handle unit, lock the bolt tongue of the handle unit [5] into position in the actuator guide plate. INFORMATION If the escape or auxiliary release pin is not inserted into the swivel piece correctly, commissioning of the PSENsgate will be aborted and an error code will be issued. [3] [4] [5] [2] [1] Shorten the escape release pin The escape release pin can be shortened, if required, so that it does not extend too much into the danger zone. Operating Manual PSEN sg2c 1003267EN02 32 Installation NOTICE Inside the danger zone, the escape release pin must protrude at least 65 mm from the profile. After installation, the escape release must be checked for proper operation. When shortening the escape release pin, the material of the escape release must not exceed a temperature of 100 °C 65 mm Pin for escape release with ball handle 45 mm Pin for auxiliary release If the escape release is not to be used, the escape release pin can be shortened to a length of 45 mm and then be used for the auxiliary release. The auxiliary release pin is also avail able as an accessory (order no. 570 771). NOTICE Please note that the escape release pin must not be shorter than 45 mm, to guarantee the full holding force. 6.2 Initial installation safety switch and handle unit Check whether the present bolt tongue is correctly oriented at the handle unit. Standard is righthand door hinge at delivery (leave of the door opens to the right). Coat the thread of the ball handle with screw adhesive (e.g. Loctite 2700) and screw firmly together with the handle unit by hand. Install bolt tongue with handle unit: – Position the screwdriver in the slots of the limit stop mechanism provided (see "Un lock bolt"). – Press screwdriver towards the base plate to release the springloaded limit stop mechanism. – Engage bolt tongue with handle unit in the actuator guide. – Ensure by moving backwards and forwards towards the limit stop that the handle unit cannot be removed from the actuator guide. Operating Manual PSEN sg2c 1003267EN02 33 Installation Fig.: Unlock bolt 6.3 Second installation of safety switch and handle unit / upgrade for lefthinged gates Uninstall safety switch from the installation site. Uninstall handle unit from the gate. To do this, position the screwdriver in the slots of the limit stop mechanism provided (see graphic " Unlock bolt".) Press screwdriver towards the base plate to release the springloaded limit stop mech anism. Disengage bolt tongue with handle unit in the actuator guide. Remove exposed fixing screws. Unscrew ball handle from the handle unit. Remove the cover of the handle unit from the bolt tongue (2 countersunk screws). Take limit stop from the bolt tongue and insert it from the other side into the location hole. Turn bolt tongue around its longitudinal axis and screw together with the cover of the handle unit. Perform work steps from chapter Initial installation safety switch and handle unit [ ]. Operating Manual PSEN sg2c 1003267EN02 33 34 Installation 6.4 Inscription of buttons Press the colour covers supplied with the device into the pushbuttons in accordance with the required function. The colour covers lock into position on the pushbuttons. NOTICE The safety switch may only be operated with colour covers correctly locked into position. Once the colour covers have locked into position, they can no longer be removed. The fields below the pushbuttons can be used for inscribing the pushbuttons. The pushbut tons can be written with a lettering device for 12 mm lettering band or with 32 x 10 mm la bels (e.g. AVERY(R) article number: 3320). 6.5 Dimensions in mm 6.5.1 Drill holes (29,5) 139,6 22,5 118,5 160 160 95 72 14 41,5 7± 6 12,9 7± 6 20 74,75 11 127 133 Operating Manual PSEN sg2c 1003267EN02 35 Installation 6.5.2 PSEN sg2c3xxx 74,5 46,3 49,7 108,2 44,2 141,4 170 110 86 Ø8 465 7± 6 173 21 146,5 SW 33 Operating Manual PSEN sg2c 1003267EN02 30 36 Installation 6.5.3 PSEN sg2c5xxxxx 74,5 49,7 46,3 555 44,2 141,4 146,5 173 21 169,7 86 110 7 ±6 108,2 SW 33 Operating Manual PSEN sg2c 1003267EN02 30 37 Installation 6.5.4 PSEN sg2c5xxxxxM12/5 74,5 49,7 46,3 18,2 568 44,2 141,4 146,5 173 21 170 110 86 7± 6 108,2 SW 33 Operating Manual PSEN sg2c 1003267EN02 30 38 Adjustment Adjustment Always test the function with one of the approved evaluation devices. Check the distance between the actuator guide plate and the safety switch (see graphic). Distance between actuator guide plate and safety switch in mm 7 ±6 Operating Manual PSEN sg2c 1003267EN02 39 Maintenance Maintenance Maintenance of the escape release: Check the correct functionality of the escape release at least every once per month. When dust, humidity and dirt exposure is high we recommend that you keep to shorter intervals. Please note that the cover of the escape release has to be checked for damage and then installed again. Clean the escape release and the bolt tongue and test their mobility. Otherwise no maintenance work needs to be performed on the interlocking and guard lock ing system PSENsg2c. Please return any faulty devices to Pilz. Operating Manual PSEN sg2c 1003267EN02 40 Operation Operation Check the function of the safety switch before commissioning. Teaching in the actuator PSEN sg2cxxx (versions with basic coding) Any corresponding Pilz actuator (see Technical details) is detected as soon as it is brought into the response range. PSEN sg2cxxx 2.2 (versions with full coding) The first corresponding actuator to be detected by the safety switch (see Technical de tails) is taught in automatically as soon as it is brought into the response range. NOTICE Please note: No other actuator may be taught in once an actuator has been taught. Status indicators "Device" LED illuminates green: The unit is ready for operation "Safety Gate" LED lights up yellow: Bolt tongue is engaged "Input" LED lights up yellow: Input circuits are closed or a HIGH signal is present "Lock" LED illuminates blue: The guard locking element is engaged in the bolt tongue, guard locking is active. Signals X16 and X17 (or X26 and X27) are present. "Lock" LED illuminates green: The guard locking element is engaged in the bolt tongue, guard locking is active. Signals X16 and X17 (or X26 and X27) are not present. LED "Lock" flashes green and blue: Pushbutton 2 for access requirement was con firmed and the machine stop was requested. Pushbutton status displays (pushbutton see device versions): Pushbutton LED [1] lights up: The guard locking element is engaged in the bolt tongue, guard locking is active. Signals X16 and X17 (or X26 and X27) are not present. The pushbuttons 3 and 4 can be used depending on the requirement and device version. Pushbutton LED [3] can be used depending on the application. It is operated via the in put (see Terminal assignment). Pushbutton LED [4] can be used depending on the application. It is operated via the in put (see Terminal assignment). Operating Manual PSEN sg2c 1003267EN02 41 Operation 9.1 Status table 24 0V 0V 24 0V 24 0V 24 24 0V 24 24 24 24 24 24 24 24 24 0V 24 24 24 24 24 24 0V 0V 24 0V 24 24 LED button 1 LED Safety Gate 0V LED Lock 0V LED Input Solenoid operation X1-6 0V “Device” LED Solenoid operation X1-6 Input X1-8* Signal output X1-9 Output X1-5 0V Pushbutton 2 operated Safety outputs X1-3 and X1-4 0V Pushbutton 1 operated Inputs X2-3 and X2-4 Guard locking element engaged Bolt tongue engaged Gate closed Mode Normal 24 0V Unlock Locking Lock Power on Operating mode This table shows the change of states of the inputs and outputs and the LEDs when switch ing from the "Lock" operating mode to the "Interlock" operating mode. 24 0V 0V 24 24 24 0V 0V 24 24 * The guard locking element can be engaged either by pressing the pushbutton key for ac tivating the guard locking of the safety gate or by operating the input X 18. Operating Manual PSEN sg2c 1003267EN02 42 Operation Legend: LED on LED flashes LED off 9.2 Normal mode and Unlock mode The device is in Normal mode when delivered. Normal mode In this mode the guard locking element is only disengaged from the bolt tongue when the pushbutton 2 for access request is pressed. Unlock mode In this mode the guard locking element is disengaged from the bolt tongue as soon as there is a High signal at the terminals X16 or X26. Switching between Normal mode and Unlock mode Switch off supply voltage Press and hold the pushbutton 2 for access request and the pushbutton 1 for activating the guard locking simultaneously Switch on the supply voltage and hold both pushbuttons until "Device" LED lights up blue. Then release the pushbuttons. The active mode is signalled by quick flashing of one of the LEDs: – Normal mode: LED of pushbutton 1 for activating the guard locking and LED "Safety Gate" are flashing – Unlock mode: "Input" LED flashes Press one of the pushbuttons to change to the new mode Reset function After an error that was signalled by the red LED "Device" the device can be restarted by a reset: Rectify the error. Press the pushbutton for access request [2] and hold the pushbutton for at least 5 seconds. Operating Manual PSEN sg2c 1003267EN02 43 Operation 9.3 Remedy Fault conditions are indicated by flashing the LEDs. Some errors are displayed through periodic flashing (see table); with other errors it is possible to establish an error code through the number of flashes. Error Cause Remedy Safety switch does not re act, LED "Device" does not light Supply voltage missing/too low Check supply voltage and apply 24 V "Safety Gate" LED flashes a see section Error codes code and "Device" LED flashes red see section Error codes "Device" LED illuminates red Internal error Please contact Pilz "Input" LED flashes yellow, only one safety output switches Only one channel of the in put circuit is open (partial operation) Open both channels of the input circuit and close them again Signal output does not switch when actuator is en gaged, "SafetyGate" LED does not light up Actuator not detected Insert actuator as far as it will go Solenoid does not switch Supply voltage or voltage for solenoid operation is too low, error in the wiring Solenoid does not switch, "SafetyGate" LED does not light up Actuator not detected Safety outputs do not switch Escape or auxiliary release pin is not correctly in posi tion "Safety Gate" LED lights up and guard locking element is engaged, but the outputs are not switching. Wrong actuator, e.g. 1.1 coded actuators with 2.2 coded safety switch Check voltages and apply 24 V, check wir ing, Increase voltage for solenoid to increase tolerance, reduce cable run, Use cable with a greater conductor cross section Insert actuator as far as it will go Check whether the LED "Lock / Area Safe" flashes red Position the escape or auxiliary release pin as far as it will go Perform reset Insert correct actuator Error codes Error codes are issued after 9ß0 seconds at the latest at the LED "Safety Gate". The num ber of LED flashes corresponds to the error code. The error code consists of one digit. (4 x flashing: error code 4). The flashing sequence is constantly repeated and separated from each other by longer periods. Operating Manual PSEN sg2c 1003267EN02 44 Operation Error code Description Remedy Short circuit on 0 V DC with at least one of the two safety outputs X13 and X14 Check the wiring of terminals X13 and X14, rectify the wiring error During operation, short circuit Rectify wiring error at terminal X13 between safety output X13 and 24 V DC During operation, short circuit Rectify wiring error at terminal X14 between safety output X14 and 24 V DC At least one of the two safety out puts X13 and X14 have voltage applied during system runup Operating Manual PSEN sg2c 1003267EN02 Check the wiring of terminals X13 and X14, rectify the wiring error 45 Technical Details Order No. 570800570804 10 Technical Details Order No. 570800570804 General Approvals Sensor's mode of opera tion Codification in accordance with ISO 14119 Building class in accord ance with ISO 14119 Electrical data Supply voltage Voltage Kind Voltage tolerance Output of external power supply (DC) Max. inrush current at UB Max. switching frequency Magnet. supply voltage Max. solenoid current t <150 ms Max. cable capacitance at the safety outputs Noload, PNOZ with re lay contacts PNOZmulti, PNOZelog, PSS Max. inrush current im pulse Current pulse, A1 Pulse duration, A1 Max. unit fuse protection in accordance with UL Max. overall cable resist ance Rlmax Singlechannel at UB DC Inputs Number Voltage at inputs Input current range ESTOP Number of N/C contacts Release type, ESTOP Operating Manual PSEN sg2c 1003267EN02 570800 CE, TÜV 570802 CE, TÜV 570804 CE, TÜV Transponder Transponder Transponder Low Low Low 570800 570802 570804 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 1,5 A 1,5 A 1,5 A 40 nF 40 nF 40 nF 70 nF 70 nF 70 nF 5,00 A 0,0002 ms 5,00 A 0,0002 ms 5,00 A 0,0002 ms 3A 3A 3A 1000 Ohm 570800 24 V DC 5,0 mA 570800 Turn release 1000 Ohm 570802 24 V DC 5,0 mA 570802 Turn release 1000 Ohm 570804 24 V DC 5,0 mA 570804 – – 46 Technical Details Order No. 570800570804 ESTOP Utilisation category In accordance with the standard Contacts, AC15 at Current Contacts, DC13 at Current Mechanical life Signal output Output voltage Max. current Section stop Number of N/C contacts Release type Utilisation category In accordance with the standard Contacts AC15 at Max. current Contacts DC13 at Max. current Mechanical life Signal output Output voltage Max. current Semiconductor outputs OSSD safety outputs Signal outputs Switching current per out put Breaking capacity per out put Residual current at "0" signal Short circuitproof Pushbutton Utilisation category In accordance with the standard Contacts AC12 at Max. current Contacts DC12 at Max. current Electrical life Mechanical life Contact material Operating Manual PSEN sg2c 1003267EN02 570800 570802 570804 EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles – – – – – – 24 V 100 mA 570800 – – 24 V 100 mA 570802 – – – – 570804 Turn release – – – – – – – – – – – – EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles – – 570800 – – 570802 24 V 100 mA 570804 500 mA 500 mA 500 mA 12,0 W 12,0 W 12,0 W 0,20 mA Yes 570800 0,20 mA Yes 570802 0,20 mA Yes 570804 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 47 Technical Details Order No. 570800570804 Times Test pulse duration, safety outputs Switchon delay after UB is applied Inputs typ. Inputs max. Actuator typ. Actuator max. Delayon deenergisation Inputs typ. Inputs max. Actuator typ. Actuator max. Supply interruption before deenergisation in the in put circuit Simultaneity, channel 1 and 2 Environmental data Metal surface temperature Ambient temperature In accordance with the standard Temperature range Storage temperature In accordance with the standard Temperature range Climatic suitability In accordance with the standard Humidity EMC Vibration In accordance with the standard Frequency Amplitude Shock stress In accordance with the standard Acceleration Duration Operating Manual PSEN sg2c 1003267EN02 570800 570802 570804 450 µs 450 µs 450 µs 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 20,0 ms 20,0 ms 20,0 ms 7 ms 570800 40 °C 7 ms 570802 40 °C 7 ms 570804 40 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 60068227 30g 11 ms EN 60068227 30g 11 ms EN 60068227 30g 11 ms 48 Technical Details Order No. 570800570804 Environmental data Airgap creepage Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Housing Mechanical data Escape release available Mechanical life Minimum holding force Max. vertical offset Max. lateral offset Max. angular offset Actuator 1 Operating distances Assured operating dis tance Sao Min. operating distance Somin Typical operating dis tance So Assured release dis tance Sar Change of operating distance with temperat ure changes Typ. hysteresis Connection type Cable Material Top Actuator Dimensions Height Width Depth Actuator dimensions Height Width Depth Weight of actuator Weight 570800 570802 570804 III 30 V III 30 V III 30 V 1,00 kV 1,00 kV 1,00 kV IP54 570800 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator IP54 570802 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator IP54 570804 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator 2,0 mm 2,0 mm 2,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 4,0 mm 4,0 mm 4,0 mm +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 465,0 mm 200,0 mm 108,0 mm 465,0 mm 200,0 mm 108,0 mm 465,0 mm 200,0 mm 108,0 mm 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.570 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.570 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.570 g The standards current on 2013 apply. Operating Manual PSEN sg2c 1003267EN02 49 Technical Details Order No. 570806570810 11 Technical Details Order No. 570806570810 General Approvals Sensor's mode of opera tion Codification in accordance with ISO 14119 Building class in accord ance with ISO 14119 Electrical data Supply voltage Voltage Kind Voltage tolerance Output of external power supply (DC) Max. inrush current at UB Max. switching frequency Magnet. supply voltage Max. solenoid current t <150 ms Max. cable capacitance at the safety outputs Noload, PNOZ with re lay contacts PNOZmulti, PNOZelog, PSS Max. inrush current im pulse Current pulse, A1 Pulse duration, A1 Max. unit fuse protection in accordance with UL Max. overall cable resist ance Rlmax Singlechannel at UB DC Inputs Number Voltage at inputs Input current range Section stop Number of N/C contacts Release type Operating Manual PSEN sg2c 1003267EN02 570806 CE, TÜV 570808 CE, TÜV 570810 CE, TÜV Transponder Transponder Transponder Low Low Low 570806 570808 570810 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 1,5 A 1,5 A 1,5 A 40 nF 40 nF 40 nF 70 nF 70 nF 70 nF 5,00 A 0,0002 ms 5,00 A 0,0002 ms 5,00 A 0,0002 ms 3A 3A 3A 1000 Ohm 570806 24 V DC 5,0 mA 570806 Turn release 1000 Ohm 570808 24 V DC 5,0 mA 570808 – – 1000 Ohm 570810 24 V DC 5,0 mA 570810 – – 50 Technical Details Order No. 570806570810 Section stop Utilisation category In accordance with the standard Contacts AC15 at Max. current Contacts DC13 at Max. current Mechanical life Signal output Output voltage Max. current Semiconductor outputs OSSD safety outputs Signal outputs Switching current per out put Breaking capacity per out put Residual current at "0" signal Short circuitproof Pushbutton Utilisation category In accordance with the standard Contacts AC12 at Max. current Contacts DC12 at Max. current Electrical life Mechanical life Contact material Times Test pulse duration, safety outputs Switchon delay after UB is applied Inputs typ. Inputs max. Actuator typ. Actuator max. Delayon deenergisation Inputs typ. Inputs max. Actuator typ. Actuator max. Operating Manual PSEN sg2c 1003267EN02 570806 570808 570810 EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles – – – – – – – – – – – – 24 V 100 mA 570806 – – 570808 – – 570810 500 mA 500 mA 500 mA 12,0 W 12,0 W 12,0 W 0,20 mA Yes 570806 0,20 mA Yes 570808 0,20 mA Yes 570810 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570806 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570808 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570810 450 µs 450 µs 450 µs 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 51 Technical Details Order No. 570806570810 Times Supply interruption before deenergisation in the in put circuit Simultaneity, channel 1 and 2 Environmental data Metal surface temperature Ambient temperature In accordance with the standard Temperature range Storage temperature In accordance with the standard Temperature range Climatic suitability In accordance with the standard Humidity EMC Vibration In accordance with the standard Frequency Amplitude Shock stress In accordance with the standard Acceleration Duration Airgap creepage Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Housing Mechanical data Escape release available Mechanical life Minimum holding force Max. vertical offset Max. lateral offset Operating Manual PSEN sg2c 1003267EN02 570806 570808 570810 20,0 ms 20,0 ms 20,0 ms 7 ms 570806 40 °C 7 ms 570808 40 °C 7 ms 570810 40 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 60068227 30g 11 ms EN 60068227 30g 11 ms EN 60068227 30g 11 ms III 30 V III 30 V III 30 V 1,00 kV 1,00 kV 1,00 kV IP54 570806 Yes 200,000 cycles 1.000 N 5 mm 3 mm IP54 570808 Yes 200,000 cycles 1.000 N 5 mm 3 mm IP54 570810 Yes 200,000 cycles 1.000 N 5 mm 3 mm 52 Technical Details Order No. 570806570810 Mechanical data Max. angular offset Actuator 1 Operating distances Assured operating dis tance Sao Min. operating distance Somin Typical operating dis tance So Assured release dis tance Sar Change of operating distance with temperat ure changes Typ. hysteresis Connection type Cable Material Top Actuator Dimensions Height Width Depth Actuator dimensions Height Width Depth Weight of actuator Weight 570806 1,5 deg PSEN sg2 actuator 570808 1,5 deg PSEN sg2 actuator 570810 1,5 deg PSEN sg2 actuator 2,0 mm 2,0 mm 2,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 4,0 mm 4,0 mm 4,0 mm +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 465,0 mm 200,0 mm 108,0 mm 465,0 mm 200,0 mm 108,0 mm 465,0 mm 200,0 mm 108,0 mm 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.570 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.570 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.570 g The standards current on 2013 apply. Operating Manual PSEN sg2c 1003267EN02 53 Technical Details Order No. 570812570816 12 Technical Details Order No. 570812570816 General Approvals Sensor's mode of opera tion Codification in accordance with ISO 14119 Building class in accord ance with ISO 14119 Electrical data Supply voltage Voltage Kind Voltage tolerance Output of external power supply (DC) Max. inrush current at UB Max. switching frequency Magnet. supply voltage Max. solenoid current t <150 ms Max. cable capacitance at the safety outputs Noload, PNOZ with re lay contacts PNOZmulti, PNOZelog, PSS Max. inrush current im pulse Current pulse, A1 Pulse duration, A1 Max. unit fuse protection in accordance with UL Max. overall cable resist ance Rlmax Singlechannel at UB DC Inputs Number Voltage at inputs Input current range ESTOP Number of N/C contacts Release type, ESTOP Operating Manual PSEN sg2c 1003267EN02 570812 CE, TÜV 570814 CE, TÜV 570816 CE, TÜV Transponder Transponder Transponder Low Low Low 570812 570814 570816 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 1,5 A 1,5 A 1,5 A 40 nF 40 nF 40 nF 70 nF 70 nF 70 nF 5,00 A 0,0002 ms 5,00 A 0,0002 ms 5,00 A 0,0002 ms 3A 3A 3A 1000 Ohm 570812 24 V DC 5,0 mA 570812 Turn release 1000 Ohm 570814 24 V DC 5,0 mA 570814 Turn release 1000 Ohm 570816 24 V DC 5,0 mA 570816 – – 54 Technical Details Order No. 570812570816 ESTOP Utilisation category In accordance with the standard Contacts, AC15 at Current Contacts, DC13 at Current Mechanical life Signal output Output voltage Max. current Section stop Number of N/C contacts Release type Utilisation category In accordance with the standard Contacts AC15 at Max. current Contacts DC13 at Max. current Mechanical life Signal output Output voltage Max. current Semiconductor outputs OSSD safety outputs Signal outputs Switching current per out put Breaking capacity per out put Residual current at "0" signal Short circuitproof Pushbutton Utilisation category In accordance with the standard Contacts AC12 at Max. current Contacts DC12 at Max. current Electrical life Mechanical life Contact material Operating Manual PSEN sg2c 1003267EN02 570812 570814 570816 EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles – – – – – – 24 V 100 mA 570812 – – 24 V 100 mA 570814 – – – – 570816 Turn release – – – – – – – – – – – – EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles – – 570812 – – 570814 24 V 100 mA 570816 500 mA 500 mA 500 mA 12,0 W 12,0 W 12,0 W 0,20 mA Yes 570812 0,20 mA Yes 570814 0,20 mA Yes 570816 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 55 Technical Details Order No. 570812570816 Times Test pulse duration, safety outputs Switchon delay after UB is applied Inputs typ. Inputs max. Actuator typ. Actuator max. Delayon deenergisation Inputs typ. Inputs max. Actuator typ. Actuator max. Supply interruption before deenergisation in the in put circuit Simultaneity, channel 1 and 2 Environmental data Metal surface temperature Ambient temperature In accordance with the standard Temperature range Storage temperature In accordance with the standard Temperature range Climatic suitability In accordance with the standard Humidity EMC Vibration In accordance with the standard Frequency Amplitude Shock stress In accordance with the standard Acceleration Duration Operating Manual PSEN sg2c 1003267EN02 570812 570814 570816 450 µs 450 µs 450 µs 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 20,0 ms 20,0 ms 20,0 ms 7 ms 570812 40 °C 7 ms 570814 40 °C 7 ms 570816 40 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 60068227 30g 11 ms EN 60068227 30g 11 ms EN 60068227 30g 11 ms 56 Technical Details Order No. 570812570816 Environmental data Airgap creepage Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Housing Mechanical data Escape release available Mechanical life Minimum holding force Max. vertical offset Max. lateral offset Max. angular offset Actuator 1 Operating distances Assured operating dis tance Sao Min. operating distance Somin Typical operating dis tance So Assured release dis tance Sar Change of operating distance with temperat ure changes Typ. hysteresis Connection type Cable Material Top Actuator Dimensions Height Width Depth Actuator dimensions Height Width Depth Weight of actuator Weight 570812 570814 570816 III 30 V III 30 V III 30 V 1,00 kV 1,00 kV 1,00 kV IP54 570812 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator IP54 570814 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator IP54 570816 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator 2,0 mm 2,0 mm 2,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 4,0 mm 4,0 mm 4,0 mm +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 555,0 mm 200,0 mm 108,0 mm 555,0 mm 200,0 mm 108,0 mm 555,0 mm 200,0 mm 108,0 mm 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.670 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.670 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.670 g The standards current on 2013 apply. Operating Manual PSEN sg2c 1003267EN02 57 Technical Details Order No. 570818570822 13 Technical Details Order No. 570818570822 General Approvals Sensor's mode of opera tion Codification in accordance with ISO 14119 Building class in accord ance with ISO 14119 Electrical data Supply voltage Voltage Kind Voltage tolerance Output of external power supply (DC) Max. inrush current at UB Max. switching frequency Magnet. supply voltage Max. solenoid current t <150 ms Max. cable capacitance at the safety outputs Noload, PNOZ with re lay contacts PNOZmulti, PNOZelog, PSS Max. inrush current im pulse Current pulse, A1 Pulse duration, A1 Max. unit fuse protection in accordance with UL Max. overall cable resist ance Rlmax Singlechannel at UB DC Inputs Number Voltage at inputs Input current range ESTOP Number of N/C contacts Release type, ESTOP Mechanical life Operating Manual PSEN sg2c 1003267EN02 570818 CE, TÜV 570820 CE, TÜV 570822 CE, TÜV Transponder Transponder Transponder Low Low Low 570818 570820 570822 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 1,5 A 1,5 A 1,5 A 40 nF 40 nF 40 nF 70 nF 70 nF 70 nF 5,00 A 0,0002 ms 5,00 A 0,0002 ms 5,00 A 0,0002 ms 3A 3A 3A 1000 Ohm 570818 24 V DC 5,0 mA 570818 Turn release 6050 cycles 1000 Ohm 570820 24 V DC 5,0 mA 570820 Turn release 6050 cycles 1000 Ohm 570822 24 V DC 5,0 mA 570822 Turn release 6050 cycles 58 Technical Details Order No. 570818570822 ESTOP Signal output Output voltage Max. current Section stop Number of N/C contacts Release type Utilisation category In accordance with the standard Contacts AC15 at Max. current Contacts DC13 at Max. current Mechanical life Signal output Output voltage Max. current Semiconductor outputs OSSD safety outputs Signal outputs Switching current per out put Breaking capacity per out put Residual current at "0" signal Short circuitproof Pushbutton Utilisation category In accordance with the standard Contacts AC12 at Max. current Contacts DC12 at Max. current Electrical life Mechanical life Contact material Times Test pulse duration, safety outputs Operating Manual PSEN sg2c 1003267EN02 570818 570820 570822 24 V 100 mA 570818 Turn release 24 V 100 mA 570820 – – 24 V 100 mA 570822 – – EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles – – – – – – – – – – – – 24 V 100 mA 570818 – – 570820 – – 570822 500 mA 500 mA 500 mA 12,0 W 12,0 W 12,0 W 0,20 mA Yes 570818 0,20 mA Yes 570820 0,20 mA Yes 570822 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570818 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570820 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570822 450 µs 450 µs 450 µs 59 Technical Details Order No. 570818570822 Times Switchon delay after UB is applied Inputs typ. Inputs max. Actuator typ. Actuator max. Delayon deenergisation Inputs typ. Inputs max. Actuator typ. Actuator max. Supply interruption before deenergisation in the in put circuit Simultaneity, channel 1 and 2 Environmental data Metal surface temperature Ambient temperature In accordance with the standard Temperature range Storage temperature In accordance with the standard Temperature range Climatic suitability In accordance with the standard Humidity EMC Vibration In accordance with the standard Frequency Amplitude Shock stress In accordance with the standard Acceleration Duration Airgap creepage Overvoltage category Pollution degree Operating Manual PSEN sg2c 1003267EN02 570818 570820 570822 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 20,0 ms 20,0 ms 20,0 ms 7 ms 570818 40 °C 7 ms 570820 40 °C 7 ms 570822 40 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 60068227 30g 11 ms EN 60068227 30g 11 ms EN 60068227 30g 11 ms III III III 60 Technical Details Order No. 570818570822 Environmental data Rated insulation voltage Rated impulse withstand voltage Protection type Housing Mechanical data Escape release available Mechanical life Minimum holding force Max. vertical offset Max. lateral offset Max. angular offset Actuator 1 Operating distances Assured operating dis tance Sao Min. operating distance Somin Typical operating dis tance So Assured release dis tance Sar Change of operating distance with temperat ure changes Typ. hysteresis Connection type Cable Material Top Actuator Dimensions Height Width Depth Actuator dimensions Height Width Depth Weight of actuator Weight 570818 30 V 570820 30 V 570822 30 V 1,00 kV 1,00 kV 1,00 kV IP54 570818 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator IP54 570820 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator IP54 570822 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator 2,0 mm 2,0 mm 2,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 4,0 mm 4,0 mm 4,0 mm +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 555,0 mm 200,0 mm 108,0 mm 555,0 mm 200,0 mm 108,0 mm 555,0 mm 200,0 mm 108,0 mm 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.670 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.670 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.670 g The standards current on 2013 apply. Operating Manual PSEN sg2c 1003267EN02 61 Technical Details Order No. 570824570828 14 Technical Details Order No. 570824570828 General Approvals Sensor's mode of opera tion Codification in accordance with ISO 14119 Building class in accord ance with ISO 14119 Electrical data Supply voltage Voltage Kind Voltage tolerance Output of external power supply (DC) Max. inrush current at UB Max. switching frequency Magnet. supply voltage Max. solenoid current t <150 ms Max. cable capacitance at the safety outputs Noload, PNOZ with re lay contacts PNOZmulti, PNOZelog, PSS Max. inrush current im pulse Current pulse, A1 Pulse duration, A1 Max. unit fuse protection in accordance with UL Max. overall cable resist ance Rlmax Singlechannel at UB DC Inputs Number Voltage at inputs Input current range ESTOP Number of N/C contacts Release type, ESTOP Operating Manual PSEN sg2c 1003267EN02 570824 CE, TÜV 570826 CE, TÜV 570828 CE, TÜV Transponder Transponder Transponder Low Low Low 570824 570826 570828 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 1,5 A 1,5 A 1,5 A 40 nF 40 nF 40 nF 70 nF 70 nF 70 nF 5,00 A 0,0002 ms 5,00 A 0,0002 ms 5,00 A 0,0002 ms 3A 3A 3A 1000 Ohm 570824 24 V DC 5,0 mA 570824 Turn release 1000 Ohm 570826 24 V DC 5,0 mA 570826 Turn release 1000 Ohm 570828 24 V DC 5,0 mA 570828 – – 62 Technical Details Order No. 570824570828 ESTOP Utilisation category In accordance with the standard Contacts, AC15 at Current Contacts, DC13 at Current Mechanical life Signal output Output voltage Max. current Section stop Number of N/C contacts Release type Utilisation category In accordance with the standard Contacts AC15 at Max. current Contacts DC13 at Max. current Mechanical life Signal output Output voltage Max. current Semiconductor outputs OSSD safety outputs Signal outputs Switching current per out put Breaking capacity per out put Residual current at "0" signal Short circuitproof Pushbutton Utilisation category In accordance with the standard Contacts AC12 at Max. current Contacts DC12 at Max. current Electrical life Mechanical life Contact material Operating Manual PSEN sg2c 1003267EN02 570824 570826 570828 EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles – – – – – – 24 V 100 mA 570824 – – 24 V 100 mA 570826 – – – – 570828 Turn release – – – – – – – – – – – – EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles – – 570824 – – 570826 24 V 100 mA 570828 500 mA 500 mA 500 mA 12,0 W 12,0 W 12,0 W 0,20 mA Yes 570824 0,20 mA Yes 570826 0,20 mA Yes 570828 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 63 Technical Details Order No. 570824570828 Times Test pulse duration, safety outputs Switchon delay after UB is applied Inputs typ. Inputs max. Actuator typ. Actuator max. Delayon deenergisation Inputs typ. Inputs max. Actuator typ. Actuator max. Supply interruption before deenergisation in the in put circuit Simultaneity, channel 1 and 2 Environmental data Metal surface temperature Ambient temperature In accordance with the standard Temperature range Storage temperature In accordance with the standard Temperature range Climatic suitability In accordance with the standard Humidity EMC Vibration In accordance with the standard Frequency Amplitude Shock stress In accordance with the standard Acceleration Duration Operating Manual PSEN sg2c 1003267EN02 570824 570826 570828 450 µs 450 µs 450 µs 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 20,0 ms 20,0 ms 20,0 ms 7 ms 570824 40 °C 7 ms 570826 40 °C 7 ms 570828 40 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 60068227 30g 11 ms EN 60068227 30g 11 ms EN 60068227 30g 11 ms 64 Technical Details Order No. 570824570828 Environmental data Airgap creepage Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Housing Mechanical data Escape release available Mechanical life Minimum holding force Max. vertical offset Max. lateral offset Max. angular offset Actuator 1 Operating distances Assured operating dis tance Sao Min. operating distance Somin Typical operating dis tance So Assured release dis tance Sar Change of operating distance with temperat ure changes Typ. hysteresis Connection type Cable Material Top Actuator Dimensions Height Width Depth Actuator dimensions Height Width Depth Weight of actuator Weight 570824 570826 570828 III 30 V III 30 V III 30 V 1,00 kV 1,00 kV 1,00 kV IP54 570824 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator IP54 570826 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator IP54 570828 Yes 200,000 cycles 1.000 N 5 mm 3 mm 1,5 deg PSEN sg2 actuator 2,0 mm 2,0 mm 2,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 4,0 mm 4,0 mm 4,0 mm +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 568,0 mm 200,0 mm 108,0 mm 568,0 mm 200,0 mm 108,0 mm 568,0 mm 200,0 mm 108,0 mm 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.690 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.690 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.690 g The standards current on 2013 apply. Operating Manual PSEN sg2c 1003267EN02 65 Technical Details Order No. 570830570834 15 Technical Details Order No. 570830570834 General Approvals Sensor's mode of opera tion Codification in accordance with ISO 14119 Building class in accord ance with ISO 14119 Electrical data Supply voltage Voltage Kind Voltage tolerance Output of external power supply (DC) Max. inrush current at UB Max. switching frequency Magnet. supply voltage Max. solenoid current t <150 ms Max. cable capacitance at the safety outputs Noload, PNOZ with re lay contacts PNOZmulti, PNOZelog, PSS Max. inrush current im pulse Current pulse, A1 Pulse duration, A1 Max. unit fuse protection in accordance with UL Max. overall cable resist ance Rlmax Singlechannel at UB DC Inputs Number Voltage at inputs Input current range Section stop Number of N/C contacts Release type Operating Manual PSEN sg2c 1003267EN02 570830 CE, TÜV 570832 CE, TÜV 570834 CE, TÜV Transponder Transponder Transponder Low Low Low 570830 570832 570834 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 1,5 A 1,5 A 1,5 A 40 nF 40 nF 40 nF 70 nF 70 nF 70 nF 5,00 A 0,0002 ms 5,00 A 0,0002 ms 5,00 A 0,0002 ms 3A 3A 3A 1000 Ohm 570830 24 V DC 5,0 mA 570830 Turn release 1000 Ohm 570832 24 V DC 5,0 mA 570832 – – 1000 Ohm 570834 24 V DC 5,0 mA 570834 – – 66 Technical Details Order No. 570830570834 Section stop Utilisation category In accordance with the standard Contacts AC15 at Max. current Contacts DC13 at Max. current Mechanical life Signal output Output voltage Max. current Semiconductor outputs OSSD safety outputs Signal outputs Switching current per out put Breaking capacity per out put Residual current at "0" signal Short circuitproof Pushbutton Utilisation category In accordance with the standard Contacts AC12 at Max. current Contacts DC12 at Max. current Electrical life Mechanical life Contact material Times Test pulse duration, safety outputs Switchon delay after UB is applied Inputs typ. Inputs max. Actuator typ. Actuator max. Delayon deenergisation Inputs typ. Inputs max. Actuator typ. Actuator max. Operating Manual PSEN sg2c 1003267EN02 570830 570832 570834 EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles – – – – – – – – – – – – 24 V 100 mA 570830 – – 570832 – – 570834 500 mA 500 mA 500 mA 12,0 W 12,0 W 12,0 W 0,20 mA Yes 570830 0,20 mA Yes 570832 0,20 mA Yes 570834 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570830 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570832 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570834 450 µs 450 µs 450 µs 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 67 Technical Details Order No. 570830570834 Times Supply interruption before deenergisation in the in put circuit Simultaneity, channel 1 and 2 Environmental data Metal surface temperature Ambient temperature In accordance with the standard Temperature range Storage temperature In accordance with the standard Temperature range Climatic suitability In accordance with the standard Humidity EMC Vibration In accordance with the standard Frequency Amplitude Shock stress In accordance with the standard Acceleration Duration Airgap creepage Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Housing Mechanical data Escape release available Mechanical life Minimum holding force Max. vertical offset Max. lateral offset Operating Manual PSEN sg2c 1003267EN02 570830 570832 570834 20,0 ms 20,0 ms 20,0 ms 7 ms 570830 40 °C 7 ms 570832 40 °C 7 ms 570834 40 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 60068227 30g 11 ms EN 60068227 30g 11 ms EN 60068227 30g 11 ms III 30 V III 30 V III 30 V 1,00 kV 1,00 kV 1,00 kV IP54 570830 Yes 200,000 cycles 1.000 N 5 mm 3 mm IP54 570832 Yes 200,000 cycles 1.000 N 5 mm 3 mm IP54 570834 Yes 200,000 cycles 1.000 N 5 mm 3 mm 68 Technical Details Order No. 570830570834 Mechanical data Max. angular offset Actuator 1 Operating distances Assured operating dis tance Sao Min. operating distance Somin Typical operating dis tance So Assured release dis tance Sar Change of operating distance with temperat ure changes Typ. hysteresis Connection type Cable Material Top Actuator Dimensions Height Width Depth Actuator dimensions Height Width Depth Weight of actuator Weight 570830 1,5 deg PSEN sg2 actuator 570832 1,5 deg PSEN sg2 actuator 570834 1,5 deg PSEN sg2 actuator 2,0 mm 2,0 mm 2,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 4,0 mm 4,0 mm 4,0 mm +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 568,0 mm 200,0 mm 108,0 mm 568,0 mm 200,0 mm 108,0 mm 568,0 mm 200,0 mm 108,0 mm 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.690 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.690 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.690 g The standards current on 2013 apply. Operating Manual PSEN sg2c 1003267EN02 69 Technical Details Order No. 570880570884 16 Technical Details Order No. 570880570884 General Approvals Sensor's mode of opera tion Codification in accordance with ISO 14119 Building class in accord ance with ISO 14119 Electrical data Supply voltage Voltage Kind Voltage tolerance Output of external power supply (DC) Max. inrush current at UB Max. switching frequency Magnet. supply voltage Max. solenoid current t <150 ms Max. cable capacitance at the safety outputs Noload, PNOZ with re lay contacts PNOZmulti, PNOZelog, PSS Max. inrush current im pulse Current pulse, A1 Pulse duration, A1 Max. unit fuse protection in accordance with UL Max. overall cable resist ance Rlmax Singlechannel at UB DC Inputs Number Voltage at inputs Input current range ESTOP Number of N/C contacts Release type, ESTOP Operating Manual PSEN sg2c 1003267EN02 570880 CE, TÜV 570882 CE, TÜV 570884 CE, TÜV Transponder Transponder Transponder High High High 570880 570882 570884 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 24 V DC 15 %/+10 % 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 2,0 W 5,00 A 1 Hz 24 V 1,5 A 1,5 A 1,5 A 40 nF 40 nF 40 nF 70 nF 70 nF 70 nF 5,00 A 0,0002 ms 5,00 A 0,0002 ms 5,00 A 0,0002 ms 3A 3A 3A 1000 Ohm 570880 24 V DC 5,0 mA 570880 Turn release 1000 Ohm 570882 24 V DC 5,0 mA 570882 Turn release 1000 Ohm 570884 24 V DC 5,0 mA 570884 Turn release 70 Technical Details Order No. 570880570884 ESTOP Utilisation category In accordance with the standard Contacts, AC15 at Current Contacts, DC13 at Current Mechanical life Signal output Output voltage Max. current Semiconductor outputs OSSD safety outputs Signal outputs Switching current per out put Breaking capacity per out put Residual current at "0" signal Short circuitproof Pushbutton Utilisation category In accordance with the standard Contacts AC12 at Max. current Contacts DC12 at Max. current Electrical life Mechanical life Contact material Times Test pulse duration, safety outputs Switchon delay after UB is applied Inputs typ. Inputs max. Actuator typ. Actuator max. Delayon deenergisation Inputs typ. Inputs max. Actuator typ. Actuator max. Operating Manual PSEN sg2c 1003267EN02 570880 570882 570884 EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles EN 6094751 48 V 1,5 A 48 V 1,5 A 6050 cycles 24 V 100 mA 570880 24 V 100 mA 570882 24 V 100 mA 570884 500 mA 500 mA 500 mA 12,0 W 12,0 W 12,0 W 0,20 mA Yes 570880 0,20 mA Yes 570882 0,20 mA Yes 570884 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570880 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570882 EN 6094751 48 V 0,1 A 48 V 0,1 A 1,000,000 cycles 1,000,000 cycles AgNi 570884 450 µs 450 µs 450 µs 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 1,1 s 15 ms 20 ms 90 ms 120 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 15 ms 20 ms 30 ms 260 ms 71 Technical Details Order No. 570880570884 Times Supply interruption before deenergisation in the in put circuit Simultaneity, channel 1 and 2 Environmental data Metal surface temperature Ambient temperature In accordance with the standard Temperature range Storage temperature In accordance with the standard Temperature range Climatic suitability In accordance with the standard Humidity EMC Vibration In accordance with the standard Frequency Amplitude Shock stress In accordance with the standard Acceleration Duration Airgap creepage Overvoltage category Pollution degree Rated insulation voltage Rated impulse withstand voltage Protection type Housing Mechanical data Escape release available Mechanical life Minimum holding force Max. vertical offset Max. lateral offset Operating Manual PSEN sg2c 1003267EN02 570880 570882 570884 20,0 ms 20,0 ms 20,0 ms 7 ms 570880 40 °C 7 ms 570882 40 °C 7 ms 570884 40 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 60068214 20 55 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 6006821/2 25 70 °C EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 60068278 93 % r. h. at 40 °C EN 55011: class A, EN 6100042, EN 6100043, EN 6100044, EN 6100045, EN 6100046, EN 6100048 EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 6006826 10,0 55,0 Hz 1,00 mm EN 60068227 30g 11 ms EN 60068227 30g 11 ms EN 60068227 30g 11 ms III 30 V III 30 V III 30 V 1,00 kV 1,00 kV 1,00 kV IP54 570880 Yes 200,000 cycles 1.000 N 5 mm 3 mm IP54 570882 Yes 200,000 cycles 1.000 N 5 mm 3 mm IP54 570884 Yes 200,000 cycles 1.000 N 5 mm 3 mm 72 Technical Details Order No. 570880570884 Mechanical data Max. angular offset Actuator 1 Operating distances Assured operating dis tance Sao Min. operating distance Somin Typical operating dis tance So Assured release dis tance Sar Change of operating distance with temperat ure changes Typ. hysteresis Connection type Cable Material Top Actuator Dimensions Height Width Depth Actuator dimensions Height Width Depth Weight of actuator Weight 570880 1,5 deg PSEN sg2 actuator 2.2 570882 1,5 deg PSEN sg2 actuator 2.2 570884 1,5 deg PSEN sg2 actuator 2.2 2,0 mm 2,0 mm 2,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 3,0 mm 4,0 mm 4,0 mm 4,0 mm +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 +0,01mm/°C 0,1 mm Springloaded terminal, plugin LiYY 24 x 0,5 mm2 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 Valox 553 Stainless steel 1.4301 465,0 mm 200,0 mm 108,0 mm 555,0 mm 200,0 mm 108,0 mm 568,0 mm 200,0 mm 108,0 mm 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.570 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.670 g 110,0 mm 195,0 mm 108,0 mm 1.390 g 2.690 g The standards current on 2013 apply. Operating Manual PSEN sg2c 1003267EN02 73 Safety characteristic data 17 Safety characteristic data Operating EN ISO mode 138491: 2008 PL EN ISO 138491: 2008 EN IEC 62061 SIL CL Category EN IEC 62061 Lambda d/ EN ISO Lambda 138491 2006, EN PFHD [1/h] IEC EN ISO 138491: 2008 TM [year] Mechan. service life [cycles] B10D 1ch. guard locking PL d 2ch. guard locking PL e 2ch. OSSD PL e Sensor with N/C contacts PL e Cat. 2 SIL CL 2 1,83E09 – – 20 Cat. 4 SIL CL 3 3,80E10 – – 20 Cat. 4 SIL CL 3 2,08E09 – – 20 200,000 cycles 200,000 cycles 200,000 cycles Cat. 4 SIL CL 3 2,08E09 0,20 75.000 20 6050 cycles NOTICE Be sure that you observe the mechanical life. The safety characteristic data are only valid as long as the values of mechanical life are met. Operating Manual PSEN sg2c 1003267EN02 74 Order reference 18 Order reference 18.1 System Product type Features Order no. PSEN sg2c3LPE Safety gate system (transponder technology) with safe inter locking and safe guard locking, 1 pushbutton illuminated, 1 pushbutton unilluminated,1 ESTOP pushbutton 570 800 PSEN sg2c3LBE Safety gate system (transponder technology) with safe inter 570 802 locking and safe guard locking, 1 pushbutton illuminated, 1, key switch, 1 ESTOP pushbutton PSEN sg2c3LPS Safety gate system (transponder technology) with safe inter locking and safe guard locking, 1 pushbutton illuminated, 1 pushbutton unilluminated, 1 section stop pushbutton PSEN sg2c3LBS Safety gate system (transponder technology) with safe inter 570 806 locking and safe guard locking, 1 pushbutton illuminated, 1, key switch, 1 ESTOP pushbutton PSEN sg2c3LPC Safety gate system (transponder technology) with safe inter 570 808 locking and safe guard locking, 1 pushbutton illuminated, push button unilluminated PSEN sg2c3LBC Safety gate system (transponder technology) with safe interlock 570 810 and safe guard locking device, 1 pushbutton illuminated, 1 key switch PSEN sg2c5LPLLE Safety gate system (transponder technology) with safe inter locking and safe guard locking, 3 pushbuttons illuminated, 1 pushbutton unilluminated, 1 ESTOP pushbutton 570 812 PSEN sg2c5LBLLE Safety gate system (transponder technology) with safe inter locking and safe guard locking, 3 pushbuttons illuminated, 1, key switch, 1 ESTOP pushbutton 570 814 PSEN sg2c5LPLLS Safety gate system (transponder technology) with safe inter locking and safe guard locking, 3 pushbuttons illuminated, 1 pushbutton unilluminated, 1 section stop pushbutton 570 816 PSEN sg2c5LBLLS Safety gate system (transponder technology) with safe inter locking and safe guard locking, 3 pushbuttons illuminated, 1, key switch, 1 section stop pushbutton 570 818 PSEN sg2c5LPLLC Safety gate system (transponder technology) with safe inter 570 820 locking and safe guard locking, 3 pushbutton illuminated, push button unilluminated PSEN sg2c5LBLLC Safety gate system (transponder technology) with safe interlock 570 822 and safe guard locking device, 3 pushbuttons illuminated, 1 key switch PSEN sg2c5LPKLE M12/5 Safety gate system (transponder technology) with safe inter locking and safe guard locking, 2 pushbuttons unilluminated, 1 key switch, 1 pushbutton unilluminated, 1 ESTOP pushbutton, 1 connection for enabling switch 570 824 PSEN sg2c5LBKLE M12/5 Safety gate system (transponder technology) with safe inter locking and safe guard locking, 2 pushbuttons illuminated, 2, key switches, 1 ESTOP pushbutton, 1 connection for enabling switch 570 826 Operating Manual PSEN sg2c 1003267EN02 570 804 75 Order reference Product type Features PSEN sg2c5LPKLS M12/5 Safety gate system (transponder technology) with safe inter 570 828 locking and safe guard locking, 2 pushbuttons unilluminated, 1 key switch, 1 pushbutton unilluminated, 1 section stop pushbut ton, connection for enabling switch PSEN sg2c5LBKLS M12/5 Safety gate system (transponder technology) with safe inter locking and safe guard locking, 2 pushbuttons illuminated, 2, key switches, 1 section stop pushbutton, connection for en abling switch PSEN sg2c5LPKLC M12/5 Safety gate system (transponder technology) with safe inter 570 832 locking and safe guard locking, 2 pushbuttons unilluminated, 1 key switch, 1 pushbutton unilluminated, connection for enabling switch PSEN sg2c5LBKLC M12/5 Safety gate system (transponder technology) with safe inter locking and safe guard locking, 2 pushbuttons unilluminated,2 key switches, connection for enabling switch 570 834 PSEN sg2c3PLE 2.2 Safety gate system (transponder technology) with safe inter locking and safe guard locking, 1 pushbutton illuminated, 1 pushbutton unilluminated 1 ESTOP pushbutton, fully coded 570 880 PSEN sg2c5LPLLE 2.2 Safety gate system (transponder technology) with safe inter locking and safe guard locking, 3 pushbuttons illuminated, 1 pushbutton unilluminated 1 ESTOP pushbutton, fully coded 570 882 PSEN sg2c5LPKLE M12/5 2.2 Safety gate system (transponder technology) with safe inter locking and safe guard locking, 2 pushbuttons unilluminated, 1 key switch, 1 pushbutton unilluminated, 1 ESTOP pushbutton, fully coded 570 884 18.2 Order no. 570 830 Safety switch Product type Features Order no. PSEN sg2c3LPE (switch) Safety switch, 1 pushbutton illuminated, 1 pushbutton unillu minated, 1 ESTOP pushbutton 570 801 PSEN sg2c3LBE (switch) Safety switch, 1 pushbutton illuminated, 1 key switch, 1 E STOP pushbutton 570 803 PSEN sg2c3LPS (switch) Safety switch, 1 pushbutton illuminated, 1 pushbutton unillu minated, 1 section stop pushbutton 570 805 PSEN sg2c3LBS (switch) Safety switch, 1 pushbutton illuminated, 1 key switch, 1 section 570 807 stop pushbutton PSEN sg2c3LPC (switch) Safety switch, 1 pushbutton illuminated, 1 pushbutton unillu minated 570 809 PSEN sg2c3LBC (switch) Safety switch, 1 pushbutton illuminated, 1 key switch 570 811 PSEN sg2c5LPLLE (switch) Safety switch, 3 pushbuttons illuminated, 1 pushbutton unillu minated, 1 ESTOP pushbutton 570 813 PSEN sg2c5LBLLE (switch) Safety switch, 3 pushbuttons illuminated, 1 key switch, 1 E STOP pushbutton 570 815 PSEN sg2c5LPLLS (switch) Safety switch, 3 pushbuttons illuminated, 1 pushbutton unillu minated, 1 section stop pushbutton 570 817 Operating Manual PSEN sg2c 1003267EN02 76 Order reference Product type Features Order no. PSEN sg2c5LBLLS (switch) Safety switch, 3 pushbuttons illuminated, 1 key switch, 1 sec tion stop pushbutton 570 819 PSEN sg2c5LPLLC (switch) Safety switch, 3 pushbuttons illuminated, 1 pushbutton unillu minated 570 821 PSEN sg2c5LBLLC (switch) Safety switch, 3 pushbuttons illuminated, 1 key switch 570 823 PSEN sg2c5LPKLE M12/5 (switch) Safety switch, 2 pushbuttons illuminated, 1 key switch, 1 push 570 825 button unilluminated, 1 ESTOP pushbutton, connection for en abling switch PSEN sg2c5LBKLE M12/5 (switch) Safety switch, 2 pushbuttons illuminated, 2 key switches, 1 E STOP pushbutton, connection for enabling switch 570 827 PSEN sg2c5LPKLS M12/5 (switch) Safety switch, 2 pushbuttons illuminated, 1 key switch, 1 push button unilluminated, 1 section stop pushbutton, connection for enabling switch 570 829 PSEN sg2c5LBKLS M12/5 (switch) Safety switch, 2 pushbuttons illuminated, 2 key switches, 1 sec 570 831 tion stop pushbutton, connection for enabling switch PSEN sg2c5LPKLC M12/5 (switch) Safety switch, 2 pushbuttons illuminated, 1 key switch, 1 push button unilluminated, connection for enabling switch PSEN sg2c5LBKLC M12/5 (switch) Safety switch, 2 pushbuttons illuminated, 2 key switch, connec 570 835 tion for enabling switch PSEN sg2c3PLE 2.2 (switch) Safety switch, 1 pushbuttons illuminated, 1 pushbutton unillu minated, 1 ESTOP pushbutton, fully coded 570 881 PSEN sg2c5LPLLE 2.2 (switch) Safety switch, 3 pushbuttons illuminated, 1 pushbutton unillu minated, 1 ESTOP pushbutton, fully coded 570 883 PSEN sg2c5LPKLE M12/5 2.2 (switch) Safety switch, 2 pushbuttons illuminated, 1 key switch, 1 push button unilluminated, 1 ESTOP pushbutton, fully coded 570 885 18.3 570 833 Handle unit with actuator Product type Features Order no. PSEN sg2c actuator Handle unit with actuator 570 890 PSEN sg2c actuator 2.2 Handle unit with fully coded actuator 570 891 18.4 Accessories Product type Features Order no. PSEN sg2 cover Housing cover of the safety switch 570 773 PSEN sg2c Set spring loaded terminals Connection terminals, rubber seal, pressure screw 570 777 PSEN sg escape release pin Pin for escape release 570 870 PSEN sg auxiliary release Pin for auxiliary release pin 570 871 PSEN sg color covers (pushbutton) 570 875 Operating Manual PSEN sg2c 1003267EN02 Colour covers for illuminated buttons 77 EC Declaration of Conformity 19 EC Declaration of Conformity This product/these products meet the requirements of the directive 2006/42/EC for ma chinery of the European Parliament and of the Council. The complete EC Declaration of Conformity is available on the Internet at www.pilz.com/downloads. Representative: Norbert Fröhlich, Pilz GmbH & Co. KG, FelixWankelStr. 2, 73760 Ost fildern, Germany Operating Manual PSEN sg2c 1003267EN02 78 Americas Australia Scandinavia Brazil +61 3 95446300 +45 74436332 Spain +55 11 97569-2804 Europe +34 938497433 +1 888-315-PILZ (315-7459) Austria Switzerland Mexico +43 1 7986263-0 +41 62 88979-30 +52 55 5572 1300 Belgium, Luxembourg The Netherlands USA (toll-free) +32 9 3217575 +31 347 320477 +1 877-PILZUSA (745-9872) France Turkey +33 3 88104000 +90 216 5775552 Asia Germany United Kingdom China +49 711 3409-444 +44 1536 462203 +86 21 60880878-216 Ireland Japan +353 21 4804983 You can reach our +81 45 471-2281 Italy international hotline on: South Korea +39 0362 1826711 +49 711 3409-444 +82 31 450 0680 support@pilz.com Pilz develops environmentally-friendly products using ecological materials and energy-saving technologies. products and environmentally-friendly solutions. Partner of: The Best of German En gineering Pilz GmbH & Co. KG Felix-Wankel-Straße 2 73760 Ostfildern, Germany Tel.: +49 711 3409-0 Fax: +49 711 3409-133 info@pilz.com www.pilz.com CMSE ® , InduraNET p ® , PAS4000 ® , PAScal ® , PASconfig ® , Pilz ® , PIT ® , PLID ® , PMCprimo ® , PMCprotego ® , PMCtendo ® , PMD ® , PMI ® , PNOZ ® , Primo ® , PSEN ® , PSS ® , PVIS ® , SafetyBUS p SafetyEYE ® , SafetyNET p ® , the spirit of safety ® are registered and protected trademarks of Pilz GmbH & Co. KG in some countries. We would point out that product features may vary from the details stated in this document, depending on the status at the time of publication and the scope of the equipment. We accept no responsibility for the validity, accuracy and entirety of the text and graphics presented in this information. Please contact our Technical Support if you have any questions. ® Canada © Pilz GmbH & Co. KG, 2011 Technical support is available from Pilz round the clock. Support 100XXXX-DE-0X 0-0-2-3-000, 2014-00 Printed in Germany Pilz GmbH & Co. KG, 2014 1003267EN02,©201405 Printed in Germany Front cover
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Author : Create Date : 2014:06:05 12:20:20+02:00 Modify Date : 2014:10:15 15:26:34+02:00 Subject : Has XFA : No XMP Toolkit : Adobe XMP Core 5.2-c001 63.139439, 2010/09/27-13:37:26 Format : application/pdf Creator : Description : Title : BA PSENsgate2 Creator Tool : SCHEMA ST4 Metadata Date : 2014:10:15 15:26:34+02:00 Keywords : Producer : ST4 PDF Engine (Build 4.1.1.1) Document ID : uuid:f88bb5c1-c0f5-4834-a5dd-25391c57f360 Instance ID : uuid:aaa63c1c-34ff-46f6-99f4-7edd31c88a1e Page Mode : UseOutlines Page Count : 79EXIF Metadata provided by EXIF.tools