Plugwise SCAN Plugwise Network Device User Manual 15a ZB9 SCAN EN

Plugwise B.V. Plugwise Network Device 15a ZB9 SCAN EN

Contents

15a_ZB9-SCAN_User Manual EN

Scan200.106.110211Presence deteconManual
2 3Scan ManualThank you for buying this extension to your Plugwise system. The Scan enables you to detect people’s presence by means of an IR sensor and to switch appliances and lighng on and o when people are or are not present in a room. The wireless Scan  is  baery  operated  and  communicates  measurement data  by  means  of  the  Plugwise  ZigBee  protocol.  This  does not  require the computer to be le  on. The Scan also  has a ‘daylight  override’  opon  to  switch  lights  o  automacally if the ambient light intensity is above a specied value for a certain period (the override opon is switched o as standard). This manual describes the installaon of a single Scan, but the same steps can be followed if you want to install mulple Scans at the same me.Before you start• Werecommendthatyoufollowthismanualcarefully;itisessenaltotakethestepsinthecorrectorder.• To be able to use the Scan, you will require a Plugwise networkconsisngofatleastaSckorStretchandaCircle+.A Plugwise network can never contain more Scans than 5 mes the number of  Circles.  What  this  manual  explains  for  the  Circle  also  applies  to  the Stealth and the Sng, or a combinaon thereof.• Ensure that you use the latest version of Source and that yourmoduleshavethelatestrmwareversion.YoucancheckthisbyclickingtheUpdatesbuoninSource.TheScanisonlysupportedifallothermoduleshavermwareversion2.36(asof13-05-2011)orlater.Ifthisisnotyetthecase,priortotheinstallaonoftheScan,theothermodulesmustrstbeupdated.InSource,checkwhethertheSckandallofthemodulesareonline.• InSource,checkwhethertheckattheboomleofthescreenshowsthattheSckisonline:• InSource,checkinthetreeat‘Overviews’toseewhetheralldevicesareonline.Thisisindicatedbygreyandyellowlights:• OnlyinsertthebaerywhenyoustarttousetheScan.AScanusesagreatdealmorepowerifitisnotconnectedtoaPlugwisenetwork.• TousetheScan,itmustbeconnectedtoaPlugwisenetwork.Finally,theScanmustbemountedontheceiling.Thesestepsareexplainedinmoredetailbelow.• Check whether all components are present. If a component ismissing,pleasecontactusassoonaspossible.Contents of the package• PerScan:    ScanMounng plateScan200.106.110211Manual1 3,6V AA baery This manual
4 51.  Adding the Scan to your Plugwise networkÌAddingtheScantoyourPlugwisenetwork.When you are asked to select a network, select the network to which the Scan must be added.ÌFillintheIDoftheScan.ThisIDisindicatedonthesckersthatareaachedtotheback.ÌClickthebuonwiththegreenarrow:Next,inserttheAAbaeryintheScan,makingnoteofthe+and–marks.ÌIfyouwanttoinstallmulpleScans,youcanaddtheIDsforalloftheScanstothelist.ThePlugwisenetworkwillthensearchfortheScanswiththenewIDsinthelist.WaitunlSourceindicatesthattheScanisonline.Thecirclewiththequesonmarkwillthenchangeintothefollowingicon:If the Scan is not found within several minutes, check whether the Plugwise network is operang correctly (refer to ‘Before you start’). If the Sck and the other modules are available in Source and the Scan is sll not shown as being online, follow the instrucons to delete the network sengs under ‘Delete network sengs’, see: ‘Advanced use’.ÌClick‘Next’andthen‘Finish’.TheScanisnowconnectedtoyournetwork.2.  Attaching the Scan to the ceilingÌTaketheScantothelocaonwhereitmustbeinstalled.TheScanmust always be in contact with its ‘parent’ (for example, a Circle),otherwise no communicaon can take place. Addionally, to ensureproperfunconingoftheScan,itshouldbeinstalledinalocaonwhereitisnotexposedtodirectsunlightorcarheadlightsandmustnotbedirectlyexposedtoanaircondionerorcentralheang/heater.ÌThisScanhasthefollowingsensivitysengs:ÌHighsensivity(parcularlysuitedtooceenvironments)ÌMediumsensivity(mainlyforhomeuse)ÌOThefollowinggureshowstherangeforthersttwosengsforvariousdegreesofregisteredmovements(forwalkingordeskwork)atvariousopmalinstallaonheights.ÌCheckwhetherSourcesllindicatesthattheScanisonline.ItcantakeseveralminutesforthenetworktoprocessthenewlocaonoftheScan.ÌAach the Scan mounng plate to the ceiling. The Up/Windowarrowontheinsideofthemounngplateindicatesthetop.EnsurethatthePlugwiselogoonthefrontendsupinahorizontalposion:Up/Window >< ResetÌWhenthemounngplateisaachedtotheceiling,slidetheScanfromaboveontotheplateunlyoufeeltheScanclickintoplace.4.50 m3.50 m6 mhigh sensivitymedium sensivity2.40 m2.70 m
6 73.  UseCommunicaon in the networkThe  Scan  contacts  one  of  the  Circles  in  your  network.  This  Circle transmits the measurement data to the other Circles. If the Circle that the Scan tries to contact is unavailable, a connecon will be made with another Circle. This can take several seconds. The computer does not need to be switched on to be able to use the Scan.Switching and insightThe Scan can be set up, for example, to switch on lighng automacally when human presence is registered. The Scan then sends a ‘Switch on’ command in case of a detected movement. If a ‘Switch on’ command has already been sent, the command will not be sent again. A switching delay can also be set  up (1–255 minutes, 10 minutes is standard)  to determine that lighng is switched o aer a certain period in which no movement is detected. In addion, ‘daylight override’ can also be acvated. Starng at a certain level of ambient light, bearing in mind the specied switching delay, the lighng is then switched o automacally. Detected  movements  will  be  ignored:  no  addional  ‘Switch  on’ command will be sent unl the quanty of ambient light falls below a certain lower-limit value.The  following  gure  shows  how  the  Scan  responds  to  detected movements and ambient light in a given scenario.An overview  of  the opons  for  linking  switching  acons to the Scan in Source, as well as other soware funcons, is available in the latest Source manual. The manual is available at www.plugwise.com/manuals. The  Scan  does  not  take  into  account  other  switching  acons  in  the network, such as those from the Plugwise Switch or Plugwise Source.Removing ScanIf the Scan will (temporarily) no longer be used, it can be removed from the Plugwise network. ÌStart Source and go to Sengs, Devices. ÌThe list of ‘Non-assigned modules’ is displayed to the right of the screen. Right-click the Scan and then click ‘Delete’. ÌThe Scan will now be ignored by the network. ÌTo also physically remove the Scan from the ceiling, follow the steps as described in secon 2, ‘Aaching the Scan to the ceiling’, in reverse order. ÌNote: remove the baery. As long as the Scan is not assigned to a network,  it  will consume more power and  the baery will therefore drain more quickly.4.  Advanced useConnecng Scan to another networkAer a Scan has been removed from a network (see the explanaon above), it can  be connected to  another  Plugwise system.  To do  this, follow the normal installaon procedure.Restarng ScanIn case of problems, the Scan can be restarted. For this purpose, a reset buon can be found on the back of the module, which can be acvated by inserng a long, thin object such as a pin or a paperclip (not a pencil or mechanical pencil, which can break o) in the hole marked ‘Reset’. When the LED light in the casing (on the front of the module) begins to ash, the Scan has restarted.Deleng network sengsYou can also delete all of the sengs saved on the Scan. As a result, the Scan will also forget its posion in the network. To delete all of the sengs, follow the instrucons as described in the secon ‘Restarng Scan’, but keep the reset buon pressed unl the rapid ashing of the LED light stops. This should take about 10 seconds.Firmware updatesWhen  a  new  rmware  version  is  available,  the  update  can  be downloaded  and  sent  to  the  Scan.  More  informaon  on  rmware updates is provided in the Source manual. Aer you send the rmware update  from Source, press the white wake buon on the top of the front of the Scan. The Scan will then waken temporarily to receive and install the rmware update.  LIGHTS ON LIGHTS ONswitchingdelayswitchingdelayupper limitambient light‘daylight override’acvated‘daylight override’deacvatedlower limitambient lightLIGHTS ONLIGHTS OFFONONON ONOFFOFFOFFmovementdetectedlevel ofambient lightSwitch on/offcommand sent
8 95.  EnvironmentOld electrical and electronic devices oen containvaluablematerials.Therefore,neverdisposeofdiscardeddevicesasnormalhouseholdrubbish.Handthedeviceintoalocalauthoritycolleconpointforelectricalandelectronicdevices.Neverthrowbaeriesawaywiththehouseholdrubbish;insteadhandtheminatthespecialcolleconpoints.6.  Technical detailsSpecicaonsParameters Min. Nominal Max. Unit CommentsInstallaonInstallaonheight 2.40 2.70 3.50 mEnvironmentOperaonal 056095˚C%RH NocondensaonStorage -4008595˚C%RH NocondensaonPower supplySupplyvoltage 3.2 3.6 3.6 Vdc Single3.6V(2400mAh)AALiionbaeryBaerylife 2 yearBasedon1rmwareupdateperyear,amaintenanceintervalof24hoursand±20switchaconsperday.Powerconsumpon 150 mWInfrared deteconWavelengthrange 3 14 μm OpmisedforpresencedeteconofpeopleDeteconangle 170 ˚ DependingonposionofinstallaonDeteconrange 0 6 mDimensions 86x80x21 mm HeightxwidthxdepthMemoryStoragecapacity 512 kByte UsedforZigBeermwareupdatesServicelife 100,000 Cycles Programming/delengZigBee communicaonBaudrate 250 kbps O-QPSKFrequency 2400 2483.5 MHz 6 channels of the 2.4 GHzISMbandBandwidth 2.0 MHz 5MHzchannelspaceReceponsensivity -92 -97 -98 dBm @1%per20-bytepacketTransmissionpower -32 3 5 dBmLEDWhentheScansendsdatawirelesslyviathePlugwiseZigBeeprotocol,aredLEDlightstartstoashinthecasing.7.  Support and contactAdetailedPlugwiseSourcemanualisdisplayedifyouclickthe‘Help’buonattheboom ofthe screen.Our websitecontainsapageoffrequentlyaskedquesons:www.plugwise.comIfyou sllhavequesons,pleasecontactusviathecontactform onthesupportpageonourwebsiteorviaourservicenumber.Youcanofcoursealsocontactusifcomponentsaremissing.Wewouldalsobepleasedtohearfromyouifyouarehappywiththedeliveredproduct.