Polvac Technical Author IGX Dryp Pump B
User Manual: Polvac IGX Dryp Pump b
Open the PDF directly: View PDF .
Page Count: 54
Download | |
Open PDF In Browser | View PDF |
A546-00-860 Issue A Original Important Safety Information Read the Safety Information in this section of the manual before installing, operating or maintaining the pump. This section must be read in conjunction with A546-00-880 and A546-00-840. http://www.bocedwards.com This page intentionally blank. CONTENTS dcs/7601/0607 Section Jun 07 Page 1 INTRODUCTION 1 2 INSTALLATION SAFETY 2 2.1 2.3 2.5 2.5.1 2.5.2 2.6 2.7 2.10 2.12 2.13 Locate the dry pumping system Connect the dry pumping system to your vacuum/exhaust system and interstage connection (if fitted) Connect the nitrogen supply (if provided) Flammable/pyrophoric materials Gas purges Leak-test the system Connect the electrical supply to the dry pumping system Connect the cooling-water hoses Commission the iGX system Install additional safety equipment 3 3 4 4 4 5 5 6 6 6 3 OPERATION 7 3.1 3.3 Start-up Manual shut-down 7 7 4 MAINTENANCE 8 4.1 4.2 4.3 Safety and maintenance frequency Relocate the system for maintenance Draining the cooling water 8 9 10 5 TRANSPORTATION, STORAGE AND DISPOSAL 11 5.1 5.3 Transportation Disposal 11 11 6 SERVICE, SPARES AND ACCESSORIES 11 6.1 Introduction 11 i PAGE i Issue A PAGE ii This page intentionally blank. Issue A ii Jun 07 Please refer to the appropriate section of this safety guide when a warning symbol appears in the installation guide (A546-00-880). 1 INTRODUCTION PAGE 1 INTRODUCTION This manual provides information for the safe installation, operation and maintenance of the Dry Pumping Systems. The following symbols may appear on the dry pumping system: Warning - refer to accompanying documentation. Warning - use protective equipment. Warning - risk of electric shock. RF earth (ground). Warning - hot surfaces. Protective earth (ground). Warning - moving parts present. Warning - heavy object. Material Safety Data Sheets for BOC Edwards supplied chemicals can be obtained by contacting BOC Edwards. Jun 07 1 Issue A 2 INSTALLATION SAFETY WARNING PAGE 2 Obey the safety instructions given below and take the appropriate precautions. If you do not, you can cause injury to people and damage to equipment. INSTALLATION SAFETY WARNING The system should not be operated with the BOC Edwards panels removed. Potential hazards on the dry pumping system include electricity, hot surfaces, process chemicals, Fomblin oil, nitrogen and water under pressure. Detailed safety information is given in Section 3 and BOC Edwards Publication Number P300-20-000 'Vacuum Pump and Vacuum System Safety'. • Only BOC Edwards engineers may install the dry pumping system. Users can be trained by BOC Edwards to conduct the tasks described in this manual, contact your local service centre or BOC Edwards for more information. • Do not remove the temporary cover or blanking plate from the dry pumping system inlet and exhaust until you are ready to connect the dry pumping system to your vacuum or exhaust-extraction system. Do not operate the dry pumping system unless the inlet and exhaust are connected to your vacuum and exhaust-extraction system. • Vent and purge the process system (if the dry pumping system is to replace an existing pumping system) with nitrogen for 15 minutes before you start installation work. Refer to Section 4. • Disconnect the other components in the process system from the electrical supply so that they cannot be operated accidentally. • Electrical, nitrogen and water supplies are all potentially hazardous energy sources. Before carrying out any maintenance the supply of these sources should be locked and tagged out. • Route and secure cables, hoses and pipework during installation to avoid possible trip hazards. • The pump system includes provision for ventilation extraction and secondary containment of oil and water leaks. Any unintended overflows or spills must be removed immediately to avoid risk of slips. • Obey all national and local rules and safety regulations when you install the dry pumping system. Consult BOC Edwards Publication Number P300-20-000 (Vacuum Pump and Vacuum System Safety) before you pump hazardous materials. This publication is available on request: contact your supplier or BOC Edwards. Issue A 2 Jun 07 2.1 Locate the dry pumping system WARNING PAGE 3 You must use suitable lifting equipment to move the system. It is too heavy to lift by hand. Do not exceed the topple angle of 10 ° when moving the pump. Wheel the system on its castors to move it into its operating position. The system should only be wheeled short distances over flat surfaces. If the floor surface is uneven or has obstacles the system should be lifted with suitable lifting equipment. 2.3 Connect the dry pumping system to your vacuum/exhaust system and interstage connection (if fitted) WARNING Pipe the exhaust to a suitable treatment plant to prevent the discharge of dangerous gases or vapours to the surrounding atmosphere. WARNING Do not operate the system with the exhaust pipeline blocked. If the exhaust pipeline is blocked, the system can generate exhaust pipeline pressures of up to 7 bar (7 x 105 Pa). Jun 07 3 Issue A INSTALLATION SAFETY WARNING 2.5 Connect the nitrogen supply (if provided) 2.5.1 Flammable/pyrophoric materials PAGE WARNING 4 You must obey the instructions and take note of any precautions given below to ensure that pumped gases do not enter their flammable ranges. INSTALLATION SAFETY When flammable or pyrophoric materials are present within the equipment you must: • Not allow air to enter the equipment • Ensure that the system is leak tight • Ensure that pumped gases do not enter their flammable range. This can be achieved by diluting flammable gases/vapours or oxidisers in the pump by supplying sufficient inert gas purge, for example dilution with nitrogen to below one quarter LEL (lower explosive limit) or, if that is not practical, to below 60% LOC (limiting oxidant concentration). • For further information please refer to Semiconductor Pumping Application Guide (Publication no. P411-00-090) or contact BOC Edwards: refer to the address page at the rear of this manual for details of your nearest BOC Edwards company. 2.5.2 Gas purges WARNING If you use inert gas purges to dilute dangerous gases to a safe level, ensure that the pump is shut down if an inert gas supply fails. Switch on the inert gas purge to remove air from the pump and the exhaust pipeline before the process starts. Switch off the purge flow at the end of the process only after the remaining flammable gases or vapours have been purged from the exhaust pipeline. If liquids that produce flammable vapours could be present in the pump foreline, then the inert gas purge to the dry pumping system should be left on all the time this liquid is present. Flammable liquids could be present in the foreline as a result of condensation or may be carried over from the process. When calculating the flow rate of inert gas required for dilution, consider the maximum flow rate for the flammable gases/vapours that could occur. For example, if a mass flow controller is being used to supply flammable gases to the process, you should assume a flow rate for flammable gases that could arise if the mass flow controller is fully open. Continually measure the inert gas flow rate: if the flow rate falls below that required, then the flow of flammable gases or vapours to the pump must be stopped. Issue A 4 Jun 07 2.6 Leak-test the system WARNING PAGE 5 2.7 Connect the electrical supply to the dry pumping system WARNING This equipment is suitable for Installation Category II as defined in IEC 60664-3. Connect the system to the electrical supply through a suitably rated isolator/connector for your dry pumping system. WARNING Ensure that the system and your electrical supply cable are suitably protected against earth (ground) faults and that the earth (ground) conductor of the electrical supply cable is longer than the phase conductors in the connector. You must fit a second protective earth (ground) conductor (with a cross-sectional area at least equal to phase conductor size) to the protective earth (ground) stud. WARNING All connections to the interface control must be double insulated or have equivalent protection. Do not connect voltages greater than 30 V a.c. or 60 V d.c. to the control/interface connections. If you do, the interface control will not provide protection against electric shock. WARNING There is no overload protection provided on the Systemable (T variant) system. Jun 07 5 Issue A INSTALLATION SAFETY Leak test the system after installation and seal any leaks found to prevent leakage of dangerous substances out of the system and leakage of air into the system. 2.10 Connect the cooling-water hoses WARNING PAGE 6 INSTALLATION SAFETY Do not leave the cooling-water supply turned on until after you complete the electrical installation of the pump. If you do, condensation may form inside the enclosure and there may be a risk of electric shock. 2.12 Commission the iGX system WARNING During some application cycles it is possible that the system may exceed OSHA 1910.95 Occupational Noise Exposure Limits, the EU noise directive 2003/10/EC or other regional noise limits dependant upon the process, duty cycle, installation or environment in which being operated. A sound pressure survey must be conducted after installation and, if necessary, controls implemented to ensure that the relevant limits are not exceeded during operation and that adequate precautions are taken to prevent personnel from exposure to high noise levels during operation. 2.13 Install additional safety equipment WARNING If your Process Tool/control system needs to know the total flow rate of nitrogen to the system for safety reasons, install suitable measurement equipment in the nitrogen supply pipeline. WARNING If you use the nitrogen purges to dilute dangerous gases to a safe level, ensure that the system shuts down if the nitrogen supply to the system fails. Issue A 6 Jun 07 3 OPERATION WARNING PAGE 7 WARNING Do not operate the system with any enclosures removed or damaged. If you do there may be a risk of an electric shock. 3.1 Start-up WARNING Ensure that it is safe to start the system. If you do not (and, for example, maintenance is being performed on components downstream of the system), you could cause injury to people. WARNING After the power is applied, the contactors will pull in automatically and all mains circuits will be energised. 3.3 Manual shut-down WARNING If you shut the system down and don’t isolate it from the electrical supply, do not disconnect the Pump Display Terminal or release control from the Pump Display Terminal or front panel. If you do the system could be started by another Module. WARNING Do not remove the inlet connections until the pump has been allowed to stop rotating and the power has been isolated. The pump can take up to three minutes to completely stop. Jun 07 7 Issue A OPERATION Do not operate the system with any enclosure panels removed or damaged and do not touch any parts of the pump(s) when the system is on. Surfaces of the pump(s) are very hot and can cause injury to people. 4 MAINTENANCE WARNING PAGE 8 MAINTENANCE Only personnel specially trained to perform electrical maintenance should attempt troubleshooting inside electrical enclosures. These enclosures contain hazardous voltages and are not operator areas. WARNING Leak test the system after maintenance and seal any leaks found to prevent leakage of dangerous substances out of the system and leakage of air into the system. 4.1 Safety and maintenance frequency WARNING Electrical, nitrogen and water supplies are all potentially hazardous energy sources. Before carrying out any maintenance the supply of these sources should be locked and tagged out. WARNING Personal protection equipment should be checked and used as specified by its supplier. Hazardous chemicals that have been pumped are located within the pumps and piping. Use of suitable protective gloves and clothing along with a respirator is recommended if contact with substances is anticipated. Particular caution should be exercised when working with Fomblin oil which may have been exposed to temperatures greater than 260 °C. Refer to BOC Edwards Material Safety Data Sheets for detailed information. • Ensure that the maintenance technician is familiar with the safety procedures which relate to the products pumped. • Allow the pumps to cool to a safe temperature before you fit lifting bolts or start maintenance work. • Vent and purge the dry pumping system with nitrogen before you start any maintenance work. • Isolate the dry pumping system and other components in the process system from the electrical supply so that they cannot be operated accidentally. Note that the emergency stop switch on the dry pumping system is not an electrical isolator, unless a disconnect box accessory is installed. • Wait for at least four minutes after you have switched off the electrical supply before you touch any electrical component on the dry pumping system. Issue A 8 Jun 07 • Route and secure cables, hoses and pipelines during maintenance to avoid possible risk of trips or entrapment. • Ensure that any oil or water collected in the secondary containment drip tray is removed before moving the system. • The enclosure panels should only be removed with the use of a special tool, when the system has been switched off and allowed to cool sufficiently (as an indication the system should be left for one hour with cooling water still connected at the flow rate specified in Table 1. • Take care to protect the sealing-faces from damage. • Do not touch or inhale the thermal breakdown products of fluorinated materials which may be present if the iGX system has been overheated to 260 °C and above. These breakdown products are very dangerous. Fluorinated materials in the iGX system may include oils, greases and seals. The iGX system may have overheated if it was misused, if it malfunctioned or if it was in a fire. BOC Edwards Material Safety Data Sheets for fluorinated materials used in the pump are available on request: contact your supplier or BOC Edwards (refer to the address page at the rear of this manual for contact details). 4.2 Relocate the system for maintenance WARNING The substances that accumulate in the exhaust-pipe, elbow and check-valve (supplied separately) can be dangerous. Do not allow these substances to come into contact with your skin or eyes. Do not inhale vapours from these substances. Fit blanking caps to the inlet and outlet flanges when you move the exhaust-pipe, elbow or check-valve around your workplace. The majority of synthetic oils/grease can cause inflammation of the skin (dermatitis). Safety precautions must be taken to prevent prolonged skin contact with these substances. Use of suitable protective gloves and clothing along with a respirator is recommended if contact with the substance is anticipated. System process gases and residue can be highly toxic. Take all necessary precautions when handling components that have, or could have, come into contact with them, including O-rings, lubricants and all exhaust accessories. WARNING You must use suitable lifting equipment to move the system. It is too heavy to lift by hand. Jun 07 9 Issue A 9 MAINTENANCE • Wear the appropriate safety-clothing when you come into contact with contaminated components. Dismantle and clean contaminated components inside a fume-cupboard. PAGE WARNING PAGE Do not exceed the topple angle of 10 ° when moving the pump. Wheel the system on its castors to move it into its operating position. The system should only be wheeled short distances over flat surfaces. If the floor surface is uneven or has obstacles the system should be lifted with suitable lifting equipment. 10 MAINTENANCE 4.3 Draining the cooling water WARNING Personal protection equipment should be checked and used as specified by its supplier. Use of suitable protective gloves and eye protection is recommended when carrying out this procedure. Issue A 10 Jun 07 5 TRANSPORTATION, STORAGE AND DISPOSAL 5.1 Transportation PAGE 11 WARNING 5.3 Disposal WARNING Dispose of the system and any components safely and in accordance with all local and national safety and environmental requirements. 6 SERVICE, SPARES AND ACCESSORIES 6.1 Introduction WARNING Whenever you return the dry pumping system to a BOC Edwards Service Centre or other BOC Edwards company, you must comply with the requirements of the Return of BOC Edwards Equipment Procedure (refer to forms HS1 and HS2 at the rear of this manual). Jun 07 11 Issue A TRANSPORTATION, STORAGE AND DISPOSAL Do not drain the oil from the pump(s) whether dangerous substances have been pumped or not. You must fit blanking plates to seal all vacuum inlet and outlet ports (to prevent possible oil leakage). You must ensure that the system is correctly labelled, if in doubt contact BOC Edwards. PAGE 12 This page intentionally blank. Issue A 12 Jun 07 A546-00-880 Issue A Original Installation, Operation and Maintenance Guide iGX Dry Pumping Systems Description Item Number iGX100L 200 V-230 V 50/60 Hz iGX100L 380 V-460 V 50/60 Hz iGX100L 200 V-230 V 50/60 Hz SS iGX100L 380 V-460 V 50/60 Hz SS iGX600L 200 V-230 V 50/60 Hz iGX600L 380 V-460 V 50/60 Hz iGX600L 200 V-230 V 50/60 Hz SS iGX600L 380 V-460 V 50/60 Hz SS iGX100N 200 V-230 V 50/60 Hz iGX100N 380 V-460 V 50/60 Hz iGX100N 200 V-230 V 50/60 Hz SS iGX600N 200 V-230 V 50/60 Hz iGX600N 380 V-460 V 50/60 Hz iGX1000N 200 V-230 V 50 Hz iGX1000N 380 V-460 V 50 Hz iGX1000N 200 V-230 V 50/60 Hz SS iGX100M 200 V- 230 V 50/60 Hz iGX100M 380 V-460 V 50/60 Hz iGX100M 200 V-230 V 50/60 Hz SS iGX100 MTi 200 V-230 V 50/60 Hz iGX100 MTi 380 V-460 V 50/60 Hz iGX100MTi 200 V-230 V 50/60 Hz SS iGX600M 200 V-230 V 50/60 Hz iGX600M 380 V-460 V 50/60 Hz iGX600M 200 V-230 V 50/60 Hz SS A546-10-958 A546-10-959 A548-10-958 A548-10-959 A546-30-958 A546-30-959 A548-30-958 A548-30-959 A546-11-958 A546-11-959 A548-11-958 A546-31-958 A546-31-959 A546-81-958 A546-81-959 A548-81-958 A546-12-958 A546-12-959 A548-12-958 A546-48-958 A546-48-959 A548-48-958 A546-32-958 A546-32-959 A548-32-958 http://www.bocedwards.com Read the Safety Guide before installing, operating or maintaining this pump. Declaration of Conformity We, Edwards, Manor Royal, Crawley, West Sussex RH10 9LW, UK declare under our sole responsibility that the product(s): iGX100L 200-230V 50/60Hz iGX100L 380-460V 50/60Hz iGX100L 200-230V 50/60Hz SS iGX100 380-460V 50/60Hz SS iGX600L 200-230V 50/60Hz iGX600L 380-460V 50/60Hz iGX600L 200-230V 50/60Hz SS iGX600L 200-230V 50/60Hz SS A546-10-958 A546-10-959 A548-10-958 A548-10-959 A546-30-958 A546-30-959 A548-30-958 A548-30-959 iGX100N 200-230V 50/60Hz iGX100N 380-460V 50/60Hz iGX100N 200-230V 50/60Hz SS iGX600N 200-230V 50/60Hz iGX600N 380-460V 50/60Hz iGX1000N 200-230V 50/60Hz iGX1000N 380-460V 50/60Hz iGX1000N 200-230V 50/60Hz SS A546-11-958 A546-11-959 A548-11-958 A546-31-958 A546-31-959 A546-81-958 A546-81-959 A548-81-958 iGX100M 200-230V 50/60Hz iGX100M 380-460V 50/60Hz iGX100M 200-230V 50/60Hz SS iGX100MTi 200-230V 50/60Hz iGX100MTi 380-460V 50/60Hz iGX100MTi 200-230V 50/60Hz SS iGX600M 200-230V 50/60Hz iGX600M 380-460V 50/60Hz iGX600M 200-230V 50/60Hz SS A546-12-958 A546-12-959 A548-12-958 A546-48-958 A546-48-959 A548-48-958 A546-32-958 A546-32-958 A548-32-958 to which this declaration relates is in conformity with the following standard(s) or other normative document(s): EN1012-2 (1997) Compressor and Vacuum Pumps Safety Requirements; Part 2 - Vacuum Pumps. EN61010-1 (2001) Safety Requirements for Electrical Equipment for Measurement, Control and Laboratory Use; Part 1 – General Requirements. EN61326 (1998 + A2:2001) Electrical Equipment for Measurement, Control and Laboratory Use – EMC Requirements (Industrial locations immunity – Class A equipment emissions). when installed in accordance with the instruction manual supplied with the pump, following the provisions of: Low Voltage Directive. Electromagnetic Compatibility Directive. Machinery Safety Directive. 28th July 2007, Shoreham Dr S.E. Ormrod, Technical Director Date and Place This product has been manufactured under a quality system registered to ISO9001 P200-01-960 Issue A 73/023/EEC 89/336/EEC 98/37/EC iGX Dry Pumping System Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. CONTENTS dcs/7662/0507 Section 1 INTRODUCTION Section Page 1 1.1 1.2 1.3 1.4 Applications The iGXL system Priority of control Active utility control 1 1 4 4 2 INSTALLATION 5 2.1 2.2 2.3 5 6 2.4 2.5 2.6 2.7 2.8 2.9 2.10 2.11 2.12 2.13 Locate the iGX system Lubrication Connect the iGX system to your vacuum/exhaust system and interstage connection (if fitted) Connect to your factory extraction system (optional) Connect the nitrogen supply (if provided) Leak-test the iGX system Connect the electrical supply Connect an additional RF earth (ground) (optional) Connect to your emergency stop circuit Connect the cooling-water hoses Accessories Commission the iGX system Install additional safety equipment 6 7 7 7 8 9 10 11 11 11 14 3 OPERATION 15 3.1 3.2 3.3 3.4 3.5 3.6 3.7 Start-up Status indicators Manual shut-down Automatic shut-down Unplanned shutdown and alarms Emergency stop Restart the pump after an emergency stop or automatic shut-down 15 16 16 17 18 18 May 07 CONTENTS (continued) Page 3.8 Single equipment monitor (SEM) 19 4 MAINTENANCE 20 4.1 4.2 4.3 4.4 Safety and maintenance frequency Relocate the system for maintenance Draining the cooling water Cleaning the pump 20 20 21 21 5 TRANSPORTATION, STORAGE AND DISPOSAL 22 5.1 5.2 5.3 Transportation Storage Disposal 22 22 22 6 SERVICE, SPARES AND ACCESSORIES 23 6.1 6.2 6.3 Introduction Service Ordering accessories 23 23 24 18 i Issue A PAGE i iGX Dry Pumping System Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. ILLUSTRATIONS PAGE ii Figure Page 1 iGX applications chart 1 2 The controls/connectors 2 3 The rear status panel LED indicators 3 4 The front panel controls 3 5 Priority of control 4 6 System arrangement to reduce effective footprint (if required) 5 7 High and low Volt coding pin arrangement 9 8 Connections to emergency stop circuit (systemable) 10 9 Installing 3/8" quick connect fittings (provided) 12 10 Gas module access panel 13 11 Flow tube (14 slm) 13 12 Flow tube (4 slm) 13 TABLES Table 1 Safety sensors 2 Accessories Issue A Page 17 24 ii May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 1 INTRODUCTION 1.1 Applications PAGE If you use the iGX system on an application for which it is not suitable (refer to Figure 1), you may invalidate your warranties. If in doubt, contact BOC Edwards who will advise you as to the suitability of the iGX system for any particular application. 1 INTRODUCTION Figure 1 - iGX applications chart Note: This product is not ATEX compliant, a range of ATEX compliant pumping systems are available, contact BOC Edwards for details. 1.2 The iGXL system Pumping a chemical that will attack the materials in contact with these process materials may, over time, result in the internal contents of the pump becoming exposed to the external environment, which may constitute a safety hazard. If in doubt, contact BOC Edwards who will advise you as to the suitability of this pump for any particular application. It is also a feature of this pump design that process gases are contained within the gearbox. This pump is not suitable for use with flammable, hazardous, toxic or corrosive gases or material. May 07 1 Issue A Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System Item Control/connector identification PAGE 2 INTRODUCTION Figure 2 - The controls/connectors Issue A 1 Protective earth (ground) M5 2 Electrical supply connection 3 Rear status panel 4 Comms 4 - MicroTIM connection (if fitted) 5 Ethernet active LED 6 Ethernet installed LED 7 Comms 3 Ethernet connection 8 Comms 2 - LON module connection 9 Comms 1 - System control/PDT 2 connection 10 Gate valve interface (EMO on T variant) 11 EMS* 12 Accessory module interface* 13 GRC interface* 14 Extraction port 15 Lifting eyebolt 16 Pumped gas inlet connection 17 RF earth (ground) cable 18 Interstage connection (if fitted) 19 Seismic bracket (if fitted, 4 off) 20 Gas Module access panel 21 Nitrogen purge port 22 Cooling-water supply connection 23 Castors (3 off) 24 Levelling feet (4 off) 25 Cooling-water return connection 26 RF earth (ground) stud M6 27 Exhaust gas outlet connection 28 Leak-test port * Not on T variants 2 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System PAGE Indication 1 Power OK (green) 2 Running (green) 3 Warning (Amber) 4 Alarm (Red) 5 Tool control (Green) 3 INTRODUCTION Item Figure 3 - The rear status panel LED indicators Item Figure 4 - The front panel controls May 07 * 3 Control/connector identification 1 EMS button* 2 Start button 3 Stop button 4 AUC LED (green) 5 Local control button/LED (green) 6 Alarm LED (red) 7 Warning LED (amber) 8 Running LED (green) 9 Power OK LED (green) 10 Comms 5 pump display terminal (PDT 1) connection Not on T variants Issue A Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 1.3 PAGE 4 Priority of control The iGX system can be controlled by a number of modules: the Pump Display Terminal (PDT), from the tool through the MicroTIM, or from the front panel local control membrane (refer to Figure 4). Only one of these can have control of the iGX system at any one time. That is, once one of these has control of the iGX system, control requests from the other are denied. INTRODUCTION The PDT indicates who is in control. LEDs are also provided on the rear panel, front panel or PDT, which illuminate to indicate 'in control'. Please refer to Figure 5. 1.4 Active utility control Active Utility Control (AUC) is available on the iGX system. This function reduces the power of the iGX system while on stand-by. The power reduction is achieved by reducing the rotational speed of the iGX pump. This function also reduces the nitrogen purge of M variant systems while in stand-by mode. Advanced Active Utility Control (AAUC) is also available. This function, in addition to AUC, can reduce the water flow of the iGX system while on stand-by, therefore allowing further reductions in power. Contact BOC Edwards for advice. The AUC functionality is controlled by the on/off process signal from the Tool Interface Module. 1. 2. 3. 4. 5. 6. PDT1 PDT2 LON Tool Front panel None in control Take Release Figure 5 - Priority of control Issue A 4 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 2 INSTALLATION 2.1 Locate the iGX system PAGE 5 1. Use suitable lifting equipment (refer to Figure 2) attached to the lifting eyebolt (15) to move the iGX system close to its final operating position. 2. Adjust the levelling feet (24) to make sure that the iGX system is level and is not supported by the castors. The lifting eyebolt must be retained for future use with this system. 3. If required, the iGX system can be secured to the floor by fitting suitable bolts or studs (not supplied) through the M10 docking points on the chassis. If vibration transmission to the floor is a concern, suitable vibration isolators (not supplied) should be fitted between the docking points and the bolt or stud, if doing this the levelling feet will need to be removed. 4. 5. If preferred, the lifting eyebolt can be removed and replaced with the lifting eyebolt hole plug supplied with the systems. Ensure that access is possible to the emergency stop button (refer to Figure 4, item 1), if not use an iGX Disconnect Box (refer to Section 6.3). Figure 6 - System arrangement to reduce effective footprint (if required) May 07 5 Issue A INSTALLATION Use the following procedure to locate the iGX system in its operating position. The iGX system must be located on a firm, level surface, to ensure that the system is not damaged. Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System If you want to secure the iGX in place to prevent inadvertent movement (for example, during an earthquake), take note of the following: • The iGX system seismic brackets (Figure 2, item 19) are designed to withstand a level 4 earthquake in a ground floor installation. • The iGX system can be secured to the floor by fitting suitable bolts or studs (not supplied) through the 17.5 mm hole in the seismic brackets. • If vibration transmission to the floor is a concern, suitable vibration isolators (not supplied) should be fitted between the seismic brackets and the bolt or stud. • Although the iGX system is supplied with four seismic brackets, two brackets are capable of protecting the system during an earthquake. The system can therefore be secured as shown in Figure 6 for example, to reduce the effective system footprint if required. • If all four seismic brackets are to be used, ensure that the bolt spacing is adequate for the floor strength and loads anticipated. PAGE 6 INSTALLATION 2.2 Lubrication The iGX system is given a charge of oil before it leaves the factory. There is no requirement to check and adjust the oil level. 2.3 Connect the iGX system to your vacuum/exhaust system and interstage connection (if fitted) Do not reuse any O-ring or O-ring assembly and do not allow debris to get into the iGX system during installation. When you connect your iGX system to your vacuum system, take note of the following: • To get the best pumping speed, ensure that the pipeline which connects the vacuum system to the iGX system is the minimum length possible and has an internal diameter not less than the iGX system inlet-port. • Ensure that all components in the vacuum pipeline have a maximum pressure rating which is greater than the highest pressure that can be generated in your system. • Incorporate flexible pipelines in the vacuum pipeline to reduce the transmission of vibration and to prevent loading of coupling-joints. We recommend that you use BOC Edwards braided flexible pipelines. The pipelines should be suitable for 110 °C. • Adequately support vacuum/exhaust pipelines to prevent the transmission of stress to pipeline coupling-joints. • Incorporate a pressure gauge in the inlet pipeline, so that you determine that the iGX system operates correctly. • You must be able to isolate the iGX system inlet from the atmosphere and from your vacuum system if you have pumped or produced corrosive chemicals. • The outlet of the exhaust pipe can have a check-valve (optional accessory) fitted which prevents the suck-back of exhaust vapours after the iGX system is shutdown. The check-valve also provides additional attenuation of the pulses in exhaust pressure. Issue A 6 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System Refer to Figure 2, items 16, 18 and 27. Use the following procedure to connect the inlet and exhaust of the iGX system to your vacuum inlet and exhaust pipeline: 1. 2. 2.4 Connect to your factory extraction system (optional) Refer to Figure 2, item 27. 2.5 Connect the nitrogen supply (if provided) CAUTION Ensure that your nitrogen supply conforms to the requirements given in the Technical Data Section. If it doesn’t flow, the sensors may not operate correctly, the gas pipelines may become blocked or the iGX system may be damaged. Refer to Figure 2, item 21. Note: For optimum nitrogen, ensure that your nitrogen supply complies with the Technical Data Section (A536-00-840). Refer to Table 1. 2.6 Leak-test the iGX system Note: If you need further information on leak-testing, look it up on the Web using the URL at the start of manual, or contact your supplier or BOC Edwards for advice. Refer to Figure 2, item 28. May 07 7 Issue A PAGE 7 INSTALLATION 3. 4. Remove the temporary cover or blanking plate from the inlet of the iGX system. Retain the nuts, bolts, washers and blanking plate for future use. Retain the temporary cover for future use on non-contaminated pumps only. Use the O-ring supplied and suitable nuts, bolts and washers (not supplied) to connect the inlet-flange (Figure 2, item 16) of the iGX system to your vacuum system. Use the NW25 trapped O-ring and clamp supplied to connect the exhaust outlet (Figure 2, item 27) on the exhaust pipe, to your exhaust extraction system. Use the NW16 trapped O-ring and clamp supplied to connect the interstage connection (Figure 2, item 18) if fitted. Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 2.7 Connect the electrical supply CAUTION PAGE 8 This is an industrial (Class A) product as defined by EN61326. To ensure compliance with European Electromagnetic Compatibility (EMC) requirements for EMC emissions, please note that it is not intended for use in domestic buildings, or in properties directly connected to an electrical supply network which also supplies domestic buildings. INSTALLATION CAUTION Do not connect voltages greater than specified in Table 5 to the control/interface connections. If you do, the interface control may be damaged. Note: Note: BOC Edwards recommend that the electrical supply be connected to a suitable isolator, which is easily accessible for maintenance and clearly identified. If you need further information on connecting the electrical supply, look it up on the Web using the URL at the start of manual, or contact your supplier or BOC Edwards for advice. Refer to Figure 2, item 2. Use the following procedure to connect the electrical supply to the iGX system. When you make the electrical supply cable, ensure that the earth (ground) conductor is longer than the phase conductors. This will ensure that if the cable is accidentally dragged and the strain relief bush on the electrical supply connector mating-half fails, the earth (ground) conductor will be the last conductor to be pulled from the connector. You must fit a secondary protective earth (ground) conductor (with a cross-sectional area at least equal to phase conductor size) to the protective earth (ground) stud. Remote: 1. 2. 3. 4. 5. 6. 7. Attach the strain relief bush to the cover. Then pass a suitable cable through the strain relief bush and cover. Refer to the technical data section or the Web for information on cable sizes. • Cables must be bare ended without ferrules to ensure correct clamping in the connector block. Connect the cable phase wires to connections a1, a2 and b1 on the connector block. Connect the earth (ground) wire of the cable to one of the two earth (ground) connections on the connector block. Refit the cover to the connector block, then tighten the strain relief bush. Fit the coding pins according to voltage variant as shown in Figure 7. Connect the mating half to the electrical supply connector (Figure 2, item 2) of the iGX system. Connect the other end of the electrical supply cable to your electrical supply through a suitable isolator. Systemable (T variants): Connect the end of the supplied electrical supply cable to your electrical supply through a suitable isolator with overload protection in accordance with local regulations - refer to the Technical Data section for pump system rating. Issue A 8 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System Low Volt pin configuration Keyed connector PE Coding pin a1 b1 Coding pin Mounting screw b2 a2 Mounting screw Mounting screw b1 a1 Mounting screw Coding pin b2 a2 Coding pin PE PAGE 9 INSTALLATION High Volt pin configuration 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14. 15. 16. 17. 18. 19. Figure 7 - High and low Volt coding pin arrangement 2.8 Connect an additional RF earth (ground) (optional) If you will operate the iGX system in an area subject to high RF (radio frequency) emissions, in accordance with good RF installation practice, we recommend that you: • Use a star washer to connect the end of the earth (ground) cable (Figure 2, item 17) connected to the iGX inlet to one of the bolts that you use to secure the inlet-flange. • Connect an additional earth (ground) cable to the RF earth (ground) stud (Figure 2, item 26). You must use a suitable low-impedance cable (for example, use braided cable). May 07 9 Issue A Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 2.9 PAGE 10 Connect to your emergency stop circuit Systemable (T variants): INSTALLATION The pump electrical supply (Figure 2, Item 2) must be connected to an emergency stop facility. The operation of the emergency stop function must immediately disconnect power from the pump when the emergency stop control is operated. Returning the emergency stop control to its normal position must not result in power being re-applied to the pump; a separate start or reset control must be used for this. The EMO connector (Figure 2, item 10) must also be connected to an emergency stop facility to stop the pump immediately, in the same way as the emergency stop function. Refer to Figure 8 and Table 5 for connection details. A. B. 1. 2. 3. 4. 5. Customer Emergency stop facility iGX system Reset/Start Electrical supply to the iGX system (Figure 2, item 2) EMO (Figure 2, item 10) Emergency stop Electrical supply Figure 8 - Connections to emergency stop circuit (systemable) Remote (optional): Note: If you do not connect to your own control equipment, you must fit the external EMS shorting plug supplied to the EMS connector (Figure 2, item 11) on the rear of the iGX system. If you do not, you will not be able to operate the iGX system. If required, you can connect your own control equipment to the iGX system to shut it down in an emergency using the EMS connection (Figure 2, item 11 and Table 5). The emergency stop control must be compliant with IEC 60947-5-1 (This should be a red self latching mushroom push button on a yellow background.). Issue A 10 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 2.10 Connect the cooling-water hoses Note: For optimum water-cooling, ensure that your cooling-water supply complies with the Technical Data Section (A536-00-840) and that they are connected in parallel. Refer to Figure 9. BOC Edwards recommend that quick connectors (provided) be used to reduce the risk of water spillage during connection/disconnection. PAGE 11 Connect the cooling-water supply as follows: INSTALLATION 1. 2. 3. 4. 5. 6. 7. 8. 9. 10. 11. Remove the dust-caps from the cooling-water inlet and outlet. Apply Loctite 577 (not supplied) to all male threads prior to installation. Connect the reducing bushing (3) to the threaded end of the coupler (2). Connect this sub-assembly to the water return port on the pumping system (4). Connect the threaded end of the nipple (1) to the customer water return line. Connect the reducing bushing (3) to the threaded end of the nipple (1). Connect this sub-assembly to the water supply port on the pumping system (5). Connect the threaded end of the coupler (2) to the customer water supply line. Connect the customer supply and return hoses to the pump. Turn on the cooling-water supply. Inspect the water hoses, pipelines and connections and check that there are no leaks. Turn off the water supply while you complete the remainder of the installation procedures. 2.11 Accessories Refer to the individual accessories manuals for installation, information, refer to Section 6.3. The disconnect box when fitted, is used to energize and isolate the power supply to the system. It also allows the isolation of the electrical supply during an emergency, and for maintenance and trouble shooting the system, thereby satisfying SEMI S2 requirements. The photohelic switch/gauge when fitted, allows monitoring for loss of extraction from the enclosure, thereby satisfying SEMI S2 requirements. 2.12 1. 2. 3. 4. Commission the iGX system Switch on the external electrical supply and check that the power OK LED (Figure 4, item 9) goes on. If the LED does not go on, Contact BOC Edwards or refer to the BOC Edwards website. Switch on the cooling-water and nitrogen supplies. Ensure that the exhaust-extraction system is not blocked (for example, that valves in the exhaust-extraction system are open). Ensure that all openings to atmospheric pressure in the foreline vacuum system are closed. May 07 11 Issue A Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 5. 6. PAGE 12 Press local control button (Figure 4, item 5). The green LED will illuminate. Then press the Start button (Figure 4, item 2). If the iGX system starts and continues to operate, continue at Step 7. If a warning or alarm condition is indicated: • Shut-down the iGX system: refer to Section 3.3. • Contact BOC Edwards or refer to the BOC Edwards website. INSTALLATION 1. 2. 3. 4. 5. Nipple 3/8 inch BSPP Coupler 3/8 inch BSPP Reducing bushing 1/4 inch BSPP to 3/8 inch BSPT Cooling-water return connection Cooling-water supply connection 3 2 AS/0688/A 1 5 4 3 1 2 Figure 9 - Installing 3/8" quick connect fittings (provided) Issue A 12 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 7. Figure 11 - Flow tube (14 slm) 1. 2. Securing screw Access panel Figure 12 - Flow tube (4 slm) Figure 10 - Gas module access panel If a different nitrogen flow rate is required please contact BOC Edwards for further advice. 8. After you have commissioned the iGX system: • If you want to continue to operate the iGX system, refer to Section 3.1, step 4. • Otherwise, shut-down the system: refer to Section 3.3. May 07 13 Issue A PAGE 13 INSTALLATION If your iGX system is an L or M variant, continue at step 8. For N variants, the nitrogen purge flow should be checked as follows; i. Open the gas module access panel by removing the securing screw. Refer to Figure 10 for the iGX100, (same location for iGX600). ii. Confirm the flow is 14 slm (factory default setting). The centre of the ball should be aligned to the 14 slm marking on the flow tube (refer to Figure 11). If not, then proceed at step (iii); iii. Close (clockwise) the 4/5 variable restrictor (marked 4/5) and confirm the flow rate is 4 slm. If not, then adjust the shaft seals variable restrictor (marked SS) until the flow tube indicates a flow rate of 4 slm (refer to Figure 12). iv. Open (anti-clockwise) the 4/5 variable restrictor until the flow tube indicates a total flow of 14 slm (refer to Figure 11). v. Replace the gas module access panel. Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 2.13 PAGE 14 Install additional safety equipment If the sensors or microprocessors fail, the total flow rate of nitrogen displayed or output by the iGX system may be incorrect. If you need to know the total flow rate of nitrogen to the dry pump for safety reasons, you should therefore fit suitable measurement equipment in the nitrogen supply pipeline. If you fit a rotameter, ensure that it is suitable for use with nitrogen and that it is correctly calibrated. INSTALLATION If the nitrogen supply to the iGX system fails, a warning message will be shown on the Pump Display Terminal (if fitted) and will be sent to the Interface Module(s) connected to the iGX system. Ensure that your installation is configured so that it remains safe if there is a failure of the nitrogen supply to the iGX system. If an alarm condition is detected (and the iGX system is not configured to ’run til crash’ refer to Section 3.4) the iGX system will shutdown automatically. You must ensure that your installation remains safe if the iGX system shuts down automatically. Issue A 14 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 3 OPERATION 3.1 Start-up PAGE 15 CAUTION OPERATION The system is designed to ride through short term power interruption and to automatically restart once the power is restored. CAUTION Do not operate the pump if the pipeline is restricted or blocked as the pump will not operate correctly and may be damaged. Refer to Section 1.1. 1. 2. 3. Switch on the cooling-water supply. Switch on the electrical supply. Check that the exhaust-extraction system is not restricted, and that any valves in the exhaust-extraction system are open. The pump can be started using either the MicroTIM, the PDT or the front panel local control membrane. Front panel local control membrane operation: 4. To operate the system using the front panel local control membrane (refer to Figure 4); • Press and hold the 'Local Control' button (Figure 4, item 5). The Green LED will illuminate when control is taken. The message 'Keys in Control' will be displayed on the PDT if connected. • Press and hold the Start button (Figure 4, item 2) until pumps starts and the Running LED (Figure 4, item 8) is illuminated. MicroTIM operation: 5. Use your control equipment to set the pump start/stop signal to the interface connector and check that the Running LED is illuminated. • Control must be taken with the MicroTIM. The message 'MicroTIM IN CONTROL' will be displayed on the PDT if connected. May 07 15 Issue A Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System PDT operation: PAGE 6. 16 If the system is to be operated using the PDT; • Connect the PDT to the required PDT connection, front (Figure 4, item 10) rear (Figure 2, item 9) OPERATION • Control must be taken with the PDT - press 'Control' button. The message 'PDT1 IN CONTROL' will be displayed if the front connection is used and the message 'PDT2 IN CONTROL' will be displayed if the rear connection is used. • Press Start button. • Press ENTER. • The system will start and the Running LEDs will be illuminated. 3.2 Status indicators Refer to Figures 3 and 4. 3.3 Manual shut-down The pump can be shutdown using either the MicroTIM, the PDT or the front panel local control membrane. Note that only the item in control can stop the pump (refer to Section 1.3). Front panel local control membrane operation: Press and hold the stop button (Figure 4, item 3) until the running LED (Figure 4, item 8) flashes. The running LED will then turn off when the pump has shutdown. MicroTIM operation: Use your control equipment to reset the pump start/stop signal to the interface connector. The Running LED (Figure 4, item 8) will then go off, and the pump running status output signal will open. PDT operation: Selecting either ’normal’ or ’fast’ shutdown will shut the pump down immediately. If the pump is not going to be required for some time, switch off the electrical supply and the cooling-water supply. Issue A 16 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 3.4 Automatic shut-down CAUTION PAGE 17 If you select ’Run 'til crash’, the pump(s) can be damaged and you may invalidate any warranties on the iGX system equipment. Note: • • • • • • • • • 'Run 'til crash' is automatically reset to 'off ' when the electrical supply is removed. POWERLOSS EMS DP ACTUAL SPEED DP THERMISTOR HIGH EXHAUST PRESSURE * DP STATUS MB ACTUAL SPEED MB STATUS MB THERMISTOR HIGH Note: * M variants only Safety sensor Shut-down condition Dry pump motor thermal snap switch (PTO) Power is shut-off to the motor if the motor winding temperature exceeds 150 °C. Inverter thermistor Power is shut-off to the motor if the temperature exceeds 110 °C. Dry pump body temperature sensor Water circuit temperature sensor + Power is shut-off to the motor if the pump body temperature exceeds 160 °C (Warning at 150 °C). Power is shut-off to the motor if the temperature exceeds 70 °C (Warning at 60 °C). Table 1 - Safety sensors + N and M variants only. May 07 17 Issue A OPERATION Normally, if an alarm condition exists, the iGX control system will shutdown the iGX system. If required you can request 'run 'til crash' operation. In this mode of operation, most alarm conditions will be ignored and the pump(s) will continue to operate. For safety reasons the following alarms will shut-down the iGX system even if you have selected 'run til crash': Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 3.5 PAGE 18 Unplanned shutdown and alarms The iGX system is fitted with a number of pump protection sensors (refer to Table 1) that will give warnings and alarms. The decision on whether or not to shutdown the pump is left with the tool. OPERATION If the iGX system has an unplanned shutdown, ensure that the cause of the shutdown is identified and rectified before restarting. If you are in any doubt, please call a BOC Edwards Service Engineer. 3.6 Emergency stop Note: The emergency stop switch is not an electrical isolator. To shut down the iGX system in an emergency, press the emergency stop switch (Figure 4, item 1). Alternatively, you can operate the emergency stop controls in your own control system if you have connected your emergency stop circuit to the iGX system as described in Section 2.9. When emergency stop is selected: • • • • • • The pump (and the booster pump) is switched off. The solenoid-valve(s) in the Gas Module close, to switch off the supply of nitrogen to the pump. The solenoid-valve(s) in the temperature control manifold(s) de-energise with loss of temperature control. The Pump Display Terminal will display 'STOP ACTIVATED'. (If connected) The Running LED will go off. The Alarm LED illuminates. 3.7 Restart the pump after an emergency stop or automatic shut-down Note: If the iGX system has automatically shut down because of high pump power, check that the pump is free to rotate before you restart the iGX system: Contact BOC Edwards or refer to the BOC Edwards website. If you have used the emergency stop switch on the front panel to shut down the iGX system, you must reset the emergency stop switch before you can restart the iGX system. Turn the emergency stop switch to reset it, then restart the iGX system as described in Section 3.1. If the iGX system has been automatically shut down because of an alarm condition, the alarm condition must be rectified before you can restart the iGX system. Restart the iGX system as described in Section 3.1. Issue A 18 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 3.8 Single equipment monitor (SEM) CAUTION PAGE 19 Ensure that you use the correct configuration setpoints for your application. If you do not, the iGX system may be damaged during operation. May 07 19 Issue A OPERATION If there is an SEM connected to your iGX system, you are able to download configuration sets, which contain preset configuration values, for example setpoints. Contact BOC Edwards or go to the BOC Edwards website for more details. Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System PAGE 20 4 MAINTENANCE 4.1 Safety and maintenance frequency MAINTENANCE The iGX system requires little user maintenance. Safety sensors fitted to the iGX system do not require routine maintenance. The maintenance operations you can carry out are described in the following sections, any other maintenance must be carried out by BOC Edwards service centres (refer to Section 6). The frequency of maintenance operations depends on your process. Adjust the frequency of maintenance operations according to your experience. When you maintain the iGX system, use BOC Edwards maintenance and service kits. These contain all of the necessary seals and other components necessary to complete maintenance operations successfully. Ensure that your nitrogen and cooling-water supplies comply with the Technical Data Section (A536-00-840) and that they are connected in parallel. Contact BOC Edwards or refer to the BOC Edwards website. 4.2 Relocate the system for maintenance CAUTION Drain the cooling-water from the iGX system as stated in Section 4.3, if you will transport or store it in conditions where the cooling-water could freeze. If you do not, cooling-water may freeze in the iGX system and damage the pump(s) and/or the cooling-water pipelines. If you want to remove the iGX system from its operating location and move it to another location where you will do maintenance, use the following procedure: 1. Purge the iGX system and shut down the iGX system as described in Section 3 and allow the iGX system to cool down. 2. Isolate the power by disconnecting the mating-half from the electrical supply connector, then isolate the water and the gas purge supply. 3. Switch off your nitrogen and cooling water supplies. Disconnect the nitrogen supply, taking care as any trapped gas under pressure is released. Disconnect the cooling-water supply followed by the cooling-water return. 4. Disconnect the inlet and outlet from the vacuum and exhaust systems and fit blanking caps. 5. If necessary, disconnect the iGX air-extraction port from your factory extraction system. 6. If necessary disconnect any accessories from the iGX system. 7. Adjust the levelling feet so that the iGX system rests on the castors. 8. Move the iGX system to the location where you will do maintenance. After maintenance is complete, re-install the iGX system as described in Section 2. Issue A 20 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 4.3 1. 2. 3. 4. 5. 7. Relocate the system for maintenance as stated in Section 4.2. Connect a regulated clean dry air supply (20 psig) to the cooling water supply connection (Figure 2, item 22). Do not turn on the air supply yet. Connect a drain hose to the cooling water return connection (Figure 2, item 25). Position the open end of the drain hose in a suitable collection container. Turn on the clean dry air supply. Monitor the drain hose outlet until no further cooling water is purged. If the system is a load-lock (L) the procedure is complete. If the system is an N or M variant continue at step 6. Connect the iGX system to a suitable mains electrical supply. The iGX control system will now energise each temperature control valve in sequence for a period of ten seconds, purging the cooling water from all flow paths. After a period of one minute from connection of the electrical supply, ensure no further cooling water is being purged. If there is, repeat the entire procedure. The cooling water drain procedure is now complete. Disconnect the air supply, electrical supply and the drain hoses. Dispose of the drained cooling water accordingly. 4.4 Cleaning the pump CAUTION Do not use cleaning materials based on strong alkalis, aggressive or chlorinated solvents. Do not use cleaning materials containing abrasives. Inspect the pump monthly and, if necessary, wipe the outside clean with a soft lint free cloth and a proprietary cleaning material based on demineralised water or isopropanol. May 07 21 Issue A PAGE 21 MAINTENANCE 6. Draining the cooling water Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System PAGE 22 5 TRANSPORTATION, STORAGE AND DISPOSAL 5.1 Transportation Follow the procedure laid out in Section 5.2 and then read form HS1 and fill out form HS2, which can be found at the back of A536-00-860. TRANSPORTATION, STORAGE AND DISPOSAL 5.2 Storage CAUTION Drain the cooling-water from the iGX system, if you will transport or store it in conditions where the cooling-water could freeze. If you do not, the coolingwater may freeze in the iGX system and damage the pump(s) and/or the cooling-water pipelines. Store the iGX system as follows: 1. 2. 3. Follow the procedure set out in Section 4.2. Store the iGX system in clean dry conditions until required. When required for use, prepare and install the iGX system as described in Section 2 of this manual. 5.3 Disposal BOC Edwards products are supported by a world-wide network of BOC Edwards Service Centres. Each Service Centre offers a wide range of options including disposal. Refer to Section 6.2 for more information. Pump system materials suitable for recycling include cast iron, steel, SG iron, PTFE, stainless steel, brass, aluminium, zinc alloy, nickel, mild steel, ABS. Take particular care with the following: • Fluoroelastomers which may have decomposed as the result of being subjected to high temperatures • Components which have been contaminated with dangerous process substances • Lithium battery. Issue A 22 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 6 SERVICE, SPARES AND ACCESSORIES 6.1 Introduction Note: Whenever you return the iGX system to a BOC Edwards Service Centre or other BOC Edwards company, you must comply with the requirements of Section 6 and with the requirements of the Return of BOC Edwards Equipment Procedure (refer to forms HS1 and HS2 at the end of Important Safety Information A536-00-860). Note: You must not drain the oil from the iGX pump. You must clearly state the pump is full of oil when you complete form HS2. PAGE 23 Order spare parts and accessories from your nearest BOC Edwards company or distributor. When you order, please state for each part required: • Model and Item Number of your equipment • Serial number (if any) • Item Number and description of the part. 6.2 Service BOC Edwards products are supported by a world-wide network of BOC Edwards Service Centres. Each Service Centre offers a wide range of options including: equipment decontamination; service exchange; repair; rebuild and testing to factory specifications. Equipment that has been serviced, repaired or rebuilt is returned with a full warranty. Your local Service Centre can also provide BOC Edwards engineers to support on-site maintenance, service or repair of your equipment. For more information about service options, contact your nearest Service Centre or other BOC Edwards company. May 07 23 Issue A SERVICE, SPARES AND ACCESSORIES BOC Edwards products, spares and accessories are available from BOC Edwards companies in Belgium, Brazil, Canada, China, France, Germany, Israel, Italy, Japan, Korea, Singapore, Switzerland, United Kingdom, U.S.A and a world-wide network of distributors. The majority of these centres employ Service Engineers who have undergone comprehensive BOC Edwards training courses. Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System 6.3 Ordering accessories Accessory PAGE 24 Item number iGX photohelic switch/gauge kit A507-27-000 iGX disconnect box 200/230 V, 50/60 Hz a.c. A507-28-000 SERVICE, SPARES AND ACCESSORIES EMS module* SPI D373-70-310 MCM D373-70-320 LAM Alliance D373-70-350 C3 D373-70-360 MicroTim SPI D373-60-310 MCM D373-60-320 TEL D373-60-330 E73 D373-60-340 LAM Alliance D373-60-350 C3 D373-60-360 Hitachi D373-60-370 Gate valve connection lead* A532-08-403 Pump Display Terminal 5-way XLR plug(PDT) D372-80-700 *Not on T variant †ASM required Extension cables 5 way XLR, 3 m D373-70-591 5 way XLR, 5 m D373-70-592 5 way XLR, 10 m D373-70-595 5 way XLR, 15 m D373-70-596 5 way XLR, 25 m D373-70-597 Table 2 - Accessories Issue A 24 May 07 Please refer to the appropriate Section in A546-00-860 for important safety information when you see a warning symbol. iGX Dry Pumping System Accessory Item number Stainless steel water quick disconnects A507-17-000 1/4" BSPP straight Parker A507-18-000 1/4" BSPP 90° Snap-tite A507-19-000 1/4" BSPP 90° Parker A507-20-000 3/8" BSPP straight Snap-tite A507-21-000 3/8" BSPP straight Parker A507-22-000 3/8" BSPP 90° Snap-tite A507-23-000 3/8" BSPP 90° Parker A507-24-000 PAGE 25 SERVICE, SPARES AND ACCESSORIES 1/4" BSPP straight Snap-tite Brass water quick disconnects 3/8" BSPP 90° Snap-tite A507-48-000 Flow control valve 1 lpm (100 only) A507-38-000 2 lpm (3/100, 6/100 and 10/100 only) A507-39-000 PDT holster D372-09-800 PDT Adaptor, 5-way XLR plug/RJ12 socket D373-70-526 *Not on T variant †ASM required Exhaust enclosure kits iGX check valve loadlock (L) A507-43-000 iGX check valve process (N and M) A507-44-000 iGX check valve with enclosure loadlock (L) A507-45-000 iGX check valve with enclosure process (N and M) A507-46-000 Accessory Support Module (ASM) iGX Water flow switch kit (Pump) D373-70-761 † A507-16-000 iGX Water flow switch kit (Combination)† iGX Water flow monitor kit † A507-25-000 A507-26-000 Table 2 - Accessories (continued) May 07 25 Issue A iGX Dry Pumping System PAGE 26 This page intentionally blank. Issue A 26 May 07 A546-00-840 Issue A Original Technical data iGX Dry Pumping Systems Description Item Number iGX100L 200 V-230 V 50/60 Hz iGX100L 380 V-460 V 50/60 Hz iGX100L 200 V-230 V 50/60 Hz SS iGX100L 380 V-460 V 50/60 Hz SS iGX600L 200 V-230 V 50/60 Hz iGX600L 380 V-460 V 50/60 Hz iGX600L 200 V-230 V 50/60 Hz SS iGX600L 380 V-460 V 50/60 Hz SS iGX100N 200 V-230 V 50/60 Hz iGX100N 380 V-460 V 50/60 Hz iGX100N 200 V-230 V 50/60 Hz SS iGX600N 200 V-230 V 50/60 Hz iGX600N 380 V-460 V 50/60 Hz iGX1000N 200 V-230 V 50 Hz iGX1000N 380 V-460 V 50 Hz iGX1000N 200 V-230 V 50/60 Hz SS iGX100M 200 V- 230 V 50/60 Hz iGX100M 380 V-460 V 50/60 Hz iGX100M 200 V-230 V 50/60 Hz SS iGX100 MTi 200 V-230 V 50/60 Hz iGX100 MTi 380 V-460 V 50/60 Hz iGX100MTi 200 V-230 V 50/60 Hz SS iGX600M 200 V-230 V 50/60 Hz iGX600M 380 V-460 V 50/60 Hz iGX600M 200 V-230 V 50/60 Hz SS A546-10-958 A546-10-959 A548-10-958 A548-10-959 A546-30-958 A546-30-959 A548-30-958 A548-30-959 A546-11-958 A546-11-959 A548-11-958 A546-31-958 A546-31-959 A546-81-958 A546-81-959 A548-81-958 A546-12-958 A546-12-959 A548-12-958 A546-48-958 A546-48-959 A548-48-958 A546-32-958 A546-32-959 A548-32-958 http://www.bocedwards.com This page intentionally blank. Technical Data 1 iGX DRY PUMPING SYSTEM 1.1 Technical data PAGE Characteristics General Dimensions (L x W x H)* 100 230 kg < 60 < 55 < 55 < 55 dB(A) Vibration level at inlet < 1.5 < 1.5 < 1.5 < 1.5 mm s-1 Vibration to the floor (when docked) < 0.05 < 0.05 < 0.05 < 0.05 mm s-1 Initial force to push the pump 0.06 0.09 0.10 0.11 kN Sustained force to push the pump 0.04 0.06 0.07 0.07 kN Warm up time to nominal pumping performance 15 15 15 15 minutes Minimum warm up time to process gas pumping 2 2 2 2 hours 100 300 600 800 m3h-1 0.005 0.0007 0.0007 0.0007 mbar 1 2 2 2 l min-1 1 1.6 1.6 1.7 kW Pump inlet flange (bolted) ISO63 ISO63 ISO100 ISO100 Exhaust gas outlet NW25 NW25 NW25 NW25 50 50 50 50 Typical to peak pumping speed (no gas purge/cold pump) Extraction port May 07 mm 220 Water-cooling Minimum flow rate required system Typical heat removed from the system † Units 200 ultimate)† Ultimate (shaft seal purge only) * 1000 120 Noise level (at Connections 600 695 x 280 x 395 695 x 280 x 695 695 x 280 x 695 695 x 280 x 695 Mass (excluding packaging) Performance 300 Refer to Web for installation drawings. Check valve accessory fitted. mm dia Table 1 - Technical data 1 Issue A 1 iGX DRY PUMPING SYSTEM Type Technical Data PAGE Type Characteristics Gas system Nitrogen supply pressure range 2 L IGX DRY PUMPING SYSTEM N M Units 2.5 to 6.9 2.5 to 6.9 bar gauge Stability of supply ± 1.4 ± 1.4 bar gauge Nitrogen supply quality <0.01 <0.01 μm Nitrogen flow rate 14 44 slm Gas module pressure 2 2 bar gauge ± 0.04 @ 0.41 ± 4.3 bar gauge Pressure transducer accuracy Mass flow transducer accuracy Interstage (I) slm Peak pumping speed, interstage 25 25 m3h-1 Ultimate, interstage 0.1 0.5 mbar NW16 NW16 Pump interstage flange Table 2 - Technical data 1.2 Electrical data Supply voltage and frequency Full load (A) Booster motor rating (kW) Pump motor rating (kW) 100 12 1.9 200/230 50/60 Hz 300 600 22 22 1.9 1.9 1.9 1.9 1000 22 1.9 1.9 100 8 1.9 380/460 50/60Hz 300 600 14 14 1.9 1.9 1.9 1.9 1000 14 1.9 1.9 Table 3 - Electrical data Issue A 2 May 07 Technical Data 1.3 Loading Levelling foot loads 300 510 266 107 216 287 45 58 43 54 600 510 243 108 216 311 56 55 61 48 1000 510 243 108 216 310 56 55 61 48 PAGE 3 iGX DRY PUMPING SYSTEM Centre of gravity A B C D E 1 2 3 4 100 510 246 103 216 167 26 35 28 31 Table 4 - Centre of gravity and levelling foot loads (Refer to Figure 1) Figure 1 - Centre of gravity and levelling foot loads May 07 3 Issue A Technical Data 1.4 PAGE 4 Connections IGX DRY PUMPING SYSTEM Description Mating connector description/ external supply rating PDT1 XLR type 5-way plug Internal supply rating 24 V d.c. 0.75 A mm2 Mains connection Weidmuller HDC 16D free socket, PG21, 6 stranded wire, 13-18 mm cable OD Ethernet connection Standard RJ45 type or Neutrik Ethercon RJ45 IEE802.3 10BaseT Ethernet LON module connection XLR type 4-way plug 24 V d.c. 0.75 A PDT2 XLR type 5-way plug 24 V d.c. 0.75 A Gate valve interface* CPC 9-way plug, standard gender, socket contacts 24 V d.c. (48 V peak), 100 mA EMO (on T variant only) 6 - common and 7 - normally closed CPC 7-way plug, standard gender, socket contacts 30 V d.c. 0.5 A EMS* XLR type 6-way plug External emergency stop switch 1 - supply, 2 - return Internal emergency stop switch 3 - common, 4 - normally open 24 V d.c. 100 mA 30 V a.c. 1 A 60 V d.c. 0.55 A Comms supply 5 - supply, 6 - return 24 V d.c. 0.5 A Accessory module interface* Preh locking DIN 8-way plug GRC interface* DIN type 6-way plug 1 - Normally open and 3 - common 30 V a.c. 1 A 2 - Normally open and 4 - normally closed 30 V d.c. 1 A 5 - Normally open and 6 - common 60 V d.c. 0.5 A 24 V d.c. 1.3 A Table 5 - iGX connector types * Issue A Not on T variant. 4 May 07 Technical Data 1.5 General data Item Description Rating Electrical Supply voltage 3-phase 200/230 V, 50/60 Hz a.c. 380/460 V, 50/60 Hz a.c. Recommended fuse/isolator rating Full load current rating, refer to Table 3. Class CC fuse rated to 600 V. Voltage tolerance range + 10% Installation category II (IEC 664) Earth leakage ≤6 Harmonic voltage distortion factor 5% Maximum supply pressure 100 psig Minimum supply pressure 36 psig Minimum flow rate required Refer to Table 1 Cooling-water supply temperature range 10 - 30 Maximum particle size 0.03 Acidity 6.5 to 8.0 pH Hardness < 100 ppm Resistivity >1 k cm Solids (turbidity) < 100 ppm Materials in contact with cooling-water Stainless steel, PTFE, copper, brass and fluoroelastomer. Cooling-water ¼” BSPT male Nitrogen ¼” tube fitting Pump, shafts and rotors Cast SG iron, steel, aluminium Seals PTFE and fluoroelastomer Connections Materials in contact with process gas 5 5 V V mA l min-1 °C mm2 Table 6 - Technical data May 07 PAGE Issue A iGX DRY PUMPING SYSTEM Water-cooling system Units Technical Data PAGE Item Description Rating Operating conditions Intended Use: Indoor use 6 Units Ambient temperature range: IGX DRY PUMPING SYSTEM Operating +5 to +40 °C Storage -45 to +55 °C Relative humidity 10 to 90 % Maximum operating altitude 2000 m Pollution degree 2 (IEC 61010) Table 6 - Technical data (continued) Issue A 6 May 07
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No XMP Toolkit : XMP Core 5.4.0 Modify Date : 2015:09:09 11:58:06-04:00 Creator Tool : FrameMaker 7.0 Create Date : 2007:09:19 14:47:55Z Metadata Date : 2015:09:09 11:58:06-04:00 Producer : Acrobat Distiller 8.0.0 (Windows) Creator : Dominic Doherty Format : application/pdf Title : Technical Author Document ID : uuid:7c6863e7-fe29-42f5-9680-10df8d20f6cd Instance ID : uuid:6a3da21b-43ec-444f-b7bd-c528b820804b Page Count : 54 Author : Dominic DohertyEXIF Metadata provided by EXIF.tools