Portal 724 MX724BT Upper Arm Blood Pressure Monitor User Manual TempConfidential

Portal 724, LLC Upper Arm Blood Pressure Monitor TempConfidential

TempConfidential_User Manual

A sideSize:375X140 mm 说明:说明书为折叠式,A⾯的尾为B⾯的头。B sideCaution:Do not take measurement during chargingQuick Start GuideUpper Arm Blood Pressure MonitorPlease read this instruction before use this monitor243Thanks for buying our Upper Arm Blood Pressure Monitor 【The important Instructions should be learned before use】Systolic pressureUnder the table of Warning and Caution glyph is mainly to alert the user to the proper and safe use of this product, to prevent damage caused by misuse or harm the user and others.  graphic ◆E L B O WSHOULDER◆◆◆◆◆◆Ver1.0【Structure and Instruction】1【Upper Arm Blood Pressure Monitor】CuffMain unitTake off the USB rubber cover, then you'll find Power/Function ButtonMX-724BT【The important Instructions should be learned before use】 【The important Instructions should be learned before use】Note: please make the USB rubber cover well kept.the USBinterface for charging【Display】indicator displayDiastolic pressure indicator displayPulse indicatordisplayPress unitPulse symbolPulse unitBattary status indicator【 】Instruction of SymbolcontentCaution Indicates wrong use may cause casualtiesNotice Indicates wrong use may cause casualtiesIndicates a general prohibition (which does not Indicates a general mandatory (that must comply Symbol Means BF ApplicationSymbol Means class II equipmentElectronic Information Products Pollution control protection use period of the product is 10 years.【 】Product ApplicationSuitable for: at least 12 years of age or older people Usage: Measuring blood pressure (systolic, diastolic) 【 】Positioning the Pressure CuffPositioning the pressure cuff: “          ”Positioning the The blood pressure monitor can be measured in either Approximately 1-2cm from the inside of elbow to the Fastness of the cuff and arm: The max gap between the arm and cuff are not more than one finger width; there is no gap between the cuff and arm when most tight, but comfortable cuff is wrapped around the arm.edge of the cuffupper arm, however, since there is a little difference in blood pressure between the left and right arms, so be sure to always use the same arm for measurement.pressure cuff, “          ”Symbol toward the shoulder. and pulse(does not apply to newborns)symbolallow things)with the thing)Symbol, indicates safety and environmental Place the blood pressure monitor display in front of your eyes, then you can see it easily.【 】Proper posture for taking a measurementStretch your backSit on the chairTake off your coat, sweater or thick clothes, bare your upper arm or leave the thin clothes.Make the centre of the  pressure cuff at the same height as your heart The best height of chair between table is 25-30cm【 】NoteTake measurements while sit in a relax and quiet When measuring elbows on the table, palms up.NoteIn: the following situations, accurate measurements Immediately after exercising or taking a bath; In cold Within 1 hour of smoking or drinking alcohol, coffee Incorrect posture, unstable mood during the Taking, moving body, arm, or bend fingures during Using mobile phone or other sources of Taking measurement continuously (between two Arrhythmia patients may have a greater impact on NoteIn: For the measurement results do not overly rely on their own judgment, be sure to accept the doctor's guidance.◆environment;  before taking measurements, take 2 or 3 deep breaths and relax to stablize blood pressure; also sit quietly for about 4-5 minutes before taking measurements.or hot places; In a moving vehicle.cannot be correct.and black tea.measurement.the measurement.electromagnetic radiation during the measurementmeasurements  should be space 2-3 minutes)the measurement results【 】Operation Instruction【 】ManualBe prepared according to the correct method descriped earlier. Click “     ” button, the displayed by default will show the last user of the measured data after whole was out. Click: “     ” button, the display shows “0 mmHg” , followed by an air pump to inflate the cuff automatically, after the end of discouraged inflatable exhaust valve will automatically ladder, in this process, blood pressure and pulse rate can be measured.   ◆◆When measurement has been completed, the blood pressure and pulse data will be displayed on screen.◆◆★Take off the cuff, press “     ” button for 5 seconds, the monitor will be turn off. Note: When the monitor working, the “    ” symbol is always flashing. 【 】Emergency stop during measurementDuring the measurement, if the user feels discomfort or other reasons need to interrupt the measurement, you can hold down the “     ” button for 5 seconds and then release it, then the monitor will go off and auto exhaust, and also can remove the cuff directly.   【 】Instruction of turn off automatically functionThe monitor with auto turn off function, when the monitor will turn off automatically after keep 2 minutes still status at the symbol “    ” flashing.  【 】Instruction of battery status indicatorThe monitor built-in rechargeable lithium battery, when the battery power is less than the preset value monitor, the battery symbol “    ” will be displayed as “red”. If the default static in the boot under the battery symbol is displayed as “red”, you need to immediately USB charging cable and output in the box for DC 5V 1A mobile phone charger is connected, and then charging cable's small plug into the machine's USB port for charging, when charging the battery symbo is displayed as “white” and “flicker” when the battery symbol to “Always” (about two hours), indicates that the battery is already full.        Caution:  1.Continuous charging cannot more than a week, since overcharging may shorten battery life.2.If the product willnot be used for a long time, battery life may be shortened and reduced performance, it may cause the battery to malfunction or cause a fire or explosion.Please read  the care and maintenance【 】3.Please make the USB rubber cover well kept.◆Using the same arm to measure your blood pressure at ◆the same time every dayPlease do not let the cuff is inflated long-term◆◆1~2cm9★中度⾼⾎压重度⾼⾎压2.Operation/transportation/ storage environmentOperation EnvironmentOperation temperature : +5~+40℃,Humidity: 15%~80% RH,Atmospheric pressure:80~105 kPa, avoid electromagnetic interference, vibration, dust, noise and large environmentTransportation and storage environment conditions, and may shake, bump environmentTemperature: -20~+55℃,Humidity: 15%~80% RH,No cold agglutination phenomenon, Atmospheric pressure: 80~105 kPa, avoid high temperatures, high humidity, direct sunlight, dusty, and causticity gasGuide of operation under electromagnetic environmentWhen the monitor works with other devices may cause electromagnetic interference,  if interference phenomena occur when you use them, you should check the work environment to identify sources of interference and take the following measures to eliminate the interference:◆◆Changing the direction of the interference deviceIncrease the interference between the device and the monitor  8【 】Product specification1.Technical specification76【 】TroubleshootingThe following table is a common fault and possible error codes will be displayed in the course may encounter, as well as causes, exclude the method, if they are consistent with the situation in use can be handled with reference to the appropriate method.    Common fault Causation SolutionPress“    ”button, the monitor cannot workBattery voltage is low or exhausted Charging powerThe cuff has been wrapped incorrectlyIncorrect positionunstable moodWear too thick clothesInfluenced by environmental factorsPlease read the relative chapter carefulNote: Blood pressure is dynamic, so the results of each measurement has some differencesFault code Causation SolutionEr1 Over pressure, measurement object measured data exceeds the measurement rangeEr2Er6When measuring the detected signal is too weakThe cuff is wrapped too loosely or not wrapped around the upper armEr3 Measurement overtimeCheck the cuff for leaks, then re-test after have a restEr4Er5Er7Er8System error Restart the monitor, then re-testExcessive movement (with signal interference, etc.)Please stay quietly when measuredAir leakage Check the cuff is leak air or notPressure error Restart and re-testBlood pressure value is abnormally high or lowCaution: Please consult the distributor when  faced with the above conditions or malfunction can not be excluded in the process of using the monitor.Measurementvalues aredifferent witheachmeasurement5( mmHg )( mmHg )12013014016018080 85 90 100 110Max hypertensionLowest hypotension2356-The most appropriate blood pressure(Target value)-Normal blood pressure-Normal hypertension-Mild hypertension-Severe hypertension-Moderate hypertension1124563【 】Blood pressure status classification standardBelow is World Health Organization (WHO), the International Society of Hypertension blood pressure (ISH) developed classification standards.  Referring to WHO / ISH blood pressure classification (1999 revised)Hypotension has no clear definition, generally think that ★the systolic blood pressure less than 100mmHg (13.3kPa) for hypotension.Note: Above symbol is for reference only, please be sure to accept the doctor's guidance.4Bluetooth status indicator【 】Product specification【 】Care and Maintenance 【 】Product specificationBlood pressure: ±3 mmHg(±0.4kPa)Measurement  Blood pressure: 20~300 mmHg(2.7~40 kPa)MX-724BTProduct Name  Upper Arm Blood Pressure MonitorProduct Model Method of  Oscillographic systemDisplay Digital LEDAccuracy Pulse: ±5% of display readingPulse: 40~199/minEquipment  Intermittent operation modeElectrical  Symbol Means BF ApplicationSymbol Means class II equipmentDevice typesafety classificationoperation moderangeMeasurementNo.Pressure  Resistive pressure sensorPressurization  Automatic pressurized inflationExhaust mode Automatic pressure release, stepped deflationAuto turn offMeasurement  From press “     ” button to start the measurement Battery built-in 3.7V 800mAh rechargable Li batteryMethod of  With output DC5V/1A USB Cable for charging Charging time About 2 hoursWeight The main unit + cuff +Li battery total is approx: Dimension Main unit: (Approx) 140.5 length x 56.3 width x 33 Arm dimension  25~36cm Note: The above specifications are subject to change height (mm)chargingperiod to display the data needs 45 secondsmethodsensor“    ”symbol is flash, the static time can be 2 minutes(Approx)263gwithout notice.To avoid damage to the unit by the accuracy and security measurements, please observe the following: The cuff balloon containing highly airtight, use caution, do not fold, pull, twist balloon. After each use, please keep the monitor and accessories tidy and properly placed, avoid strong force to the unit (such as dropping the unit on the floor).  Don't put the monitor and accessories in high temperatures, high humidity, dust or direct sunlight environment.  When cleaning the main unit, please wipe it with a soft, dry cloth, if necessary dampened with water or a neutral detergent, thoroughly wrung and then wipe, do not put it into the water to wash or use benzine, thinner, gasoline, etc. to wipe.    Don't moisten the cuff or don't wash the cuff with waterDon't attempt to disassemble or repair the unit If the product is not used for above 6 month, please  charging the battery and place it very well. Each 6  month should check the power of the battery, if the  power is exhaust, charging it very well in time.   【 】Care and MaintenancePortal 724, LLC275 Hartz Way, Suite 105, Secaucus, NJ 07094 U.S.ANote: Instructions for the folding tail A plane is the B-side of the headClose the interference device ◆-Consult the dealer or an experienced radio/TV technician  for help.-Connect the equipment into an outlet on a circuit different  from that to which the receiver is connected.-Increase the separatio between the equipment and  receiver.-Reorient or telocate the receiving antenna.If this equipment does cause harmful interference to radio or television, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interfrence by one or more of the following measures:This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference  (2) this device must accept any interference received,       including interference that may cause undesired       operation.reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. device, pursuant to part 15 of the FCC Rules. These limits are designed to provide This equipment has been tested and found to comply with the limits for a Class B digital could void the user's authority to operate the equipment.changes or modifications not expressly approved by the party responsible for compliance

Navigation menu