Position Technology POSIPIN User Manual CR R885 S manual
Position Technology Inc CR R885 S manual
Contents
- 1. CR R885 A manual
- 2. CR R885 S manual
CR R885 S manual
PIN and Proximity Reader Stand-alone System (CR-R885-S and CR-R885-SB) Installation and Operating Instructions TABLE OF CONTENTS Installation .......................................................................... 2 Mounting and Wiring ................................................................ 2 Mounting on Metal Surfaces ..................................................... 2 Technical Specifications ........................................................... 3 Feedback .................................................................................. 5 Resetting to Default .................................................................. 5 Card Presentation Test ............................................................ 5 System Programming ........................................................ 6 Section [001] Card/Code Options ............................................. 6 Section [002] Door Lock Control .............................................. 7 Section [003] Access Granted Options .................................... 7 Section [004] Display on Card Read ........................................ 8 Section [005] Keypad Lockout .................................................. 9 Section [101] Buzzer Setting .................................................... 9 Section [102] Face Light Intensity ............................................ 9 Section [103] Face Light Operation .......................................... 9 Section [104] Face Light Colour ............................................. 10 Section [200] Changing the Installer Code ............................. 10 Resetting the Installer and Master Codes to Default .............. 10 Master Programming ....................................................... 11 Sections [201] and [202] Changing the Master Codes ........... 11 Section [203] User Code Programming .................................. 11 Deleting a User Code ............................................................. 13 Section [204] User Code Reset .............................................. 14 User Operation ................................................................. 15 User Access ........................................................................... 15 Panic Alarm ............................................................................ 16 User Code Table ............................................................... 17 Warranty ............................................................................ 19 PosiPin 1 INSTALLATION To select an installation site: • Avoid wiring the PosiPin cables in the same conduit as AC power cables, lock power or signal wiring. • Reader wiring must remain a minimum of 30cm (12in) away from other wiring, such as wiring for AC power, computer data, telephones, electric locks, etc. • Avoid sites within 1.1m (3.5ft) of computer monitors or CRTs. • Avoid sites near sources of broad spectrum EMI noise, such as motors, pumps, generators, DC to AC converters, AC switching relays, power supplies and light dimmers. • Avoid sites near potential sources of RF signals, such as cellular phones, two-way radios, etc. MOUNTING AND WIRING Use the mounting plate as a guide to drill two holes to secure the mounting plate and a hole for the cable 0.95cm to 2.54cm (0.375in to 1in) wide. Place a grommet around the edge of the hole for the cable. Prepare PosiPin’s cable by cutting the cable jacket back 3.175cm (1.25in) and stripping the wires back 0.635cm (0.25in). Splice PosiPin’s wires with a recommended cable wire (see page 5) and connect as shown in Figure 1 on page 4. MOUNTING ON METAL SURFACES Although the read range may decrease, PosiPin can be mounted on metal. However, do not box in or surround the card reader with any kind of metal. If the reader must be installed in a metal enclosure, ensure that the face of the card reader is not covered and that at least 1.6" (4cm) remain between the card reader and the metal on all sides of the card reader. 2 Installation and Operating Instructions TECHNICAL SPECIFICATIONS Input Voltage: Input Current: Consumption: Frequency: Typical: 13.8VDC, min.: 11.0VDC, max: 14.5VDC Typical: 65mA @ 12.5VDC, with card: 105mA Typical: 812mW @ 12.5VDC, with card 1.31mW Exciter Field: 125KHz Pulse Modulated, receive low: 12.500KHz, Receive high: 15.625KHz Operating Temp: -35°C (-31°F) to +65°C (+149°F) Cable Distance: 152.4m (500ft.) Suggested Cables: 22AWG, 0.8mm, Multi-conductor, Alpha 5196, 5198 18AWG, 1.2mm, Multi-conductor, Alpha 5386, 5388 Belden 9553, 18AWG, 6-conductor, stranded w/ overall shield Indicators: Beeper, red LED and green LED For CR-R885-S: red and green Face Light For CR-R885-SB: blue and green Face Light Weight: 280g (9.8 oz.) Material: Black, UV resistant, ABS plastic Dimensions: 99.5mm (5.75in.) x 118.5mm (2in.) x 19.5mm (1in.) PosiPin 3 Figure 1: Connection drawing 4 Installation and Operating Instructions FEEDBACK Depending on the programming mode chosen, the feedback will differ. In the section System Programming on page 6 and Master Programming on page 11, the combinations of visual feedback and beep tones are specified step by step. Visual Feedback: When information is entered on the reader’s keypad, the red and/or green LEDs will flash, remain constant or extinguish depending on the step reached in programming. Confirmation Beep: When an operation is successfully entered, the reader emits a rapid series of beep tones (“beep-beep-beep-beep-beep”). Rejection Beep: When the system reverts to a previous status or an operation is incorrectly entered, the reader emits one long beep tone (“beeeeeeeeeep”). RESETTING TO DEFAULT To reset all sections to factory defaults, disconnect reader’s power supply. Press and hold the [1] and [2] keys simultaneously while re-connecting its power supply. Sections are reset when the reader emits a confirmation beep. CARD PRESENTATION TEST Place the card parallel to the PosiPin reader (as shown in the figure) and move it toward the reader until the reader provides audio or visual feedback. PosiPin 5 SYSTEM PROGRAMMING The Installer code (default: 000000) can program a new Installer Code PIN in section [200] and program all the system sections from [001] to [005] and [101] to [104]. To enter System Programming Mode: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter the [INSTALLER CODE] and press the [ENTER] key. Reader emits a confirmation beep and the green LED flashes. 3. Enter the 3-digit [SECTION] and press the [ENTER] key. Reader emits a confirmation beep and green LED becomes constant. 4. Enter the required [DATA] and press the [ENTER] key. The reader emits a confirmation beep and the green LED flashes. 5. To program another section, repeat steps 2 and 3. To exit, press and hold the [CLEAR] key for 4 seconds. The reader emits a rejection beep and the green LED extinguishes. SECTION [001] CARD/CODE OPTIONS PosiPin can function as a reader only, as a keypad only or as a combined reader and keypad. Option [3] by default Enter Description [0] [1] [2] [3] Keypad and reader disabled. For programming only. Reader only. Present valid card to the reader for Access Granted. Keypad only. Enter valid code on the keypad for Access Granted. Keypad and reader enabled. A user must present BOTH a valid card AND enter a valid code to receive an Access Granted. When a Card/Code option is set, it may require several seconds for the system to update the programming. The reader emits a confirmation beep once the modification is complete. 6 Installation and Operating Instructions SECTION [002] DOOR LOCK CONTROL The Door Lock Control determines the length of time the locking device remains unlatched after an Access Granted. When [0] is programmed, the lock is unlatched after an Access Granted and remains unlatched until it receives a second Access Granted (functions like a key). When [1] to [5] is programmed, the lock remains unlatched for the defined time period. Option [2] by default. Enter Description [0] [1] [2] [3] [4] [5] Card/Code Controlled Free Access (Latched) 1 second 5 seconds 10 seconds 20 seconds 60 seconds SECTION [003] ACCESS GRANTED OPTIONS The Access Granted Options depend on the Card/Code Options set in section [001]. Option [0] by default. Enter Description [0] [1] [2] Single Access Granted Dual Access Granted Dual Access Granted with Dual Panic Disarm Single Access Granted When [0] is programmed, one user can obtain Access Granted by using a valid card, code or both depending on the Card/Code Option set. PosiPin 7 Dual Access Granted When [1] is programmed, two users are required to obtain Access Granted. Each user must use a valid card, code or both depending on the Card/Code Option set. Only one user is required to disarm a Panic Alarm. Example: When the reader and the keypad are enabled, User 1 must present a valid card and enter a valid code and then User 2 must present a valid card and enter a valid code for Access Granted. Dual Access Granted with Dual Panic Disarm When [2] is programmed, two users are required to obtain Access Granted (same as Dual Access Granted) and two users are required to disarm a Panic Alarm. For example, a Panic Alarm is triggered, User 1 must present a valid card and enter a valid code and then User 2 must present a valid card and enter a valid code to disarm the alarm. SECTION [004] DISPLAY ON CARD READ The visual feedback when a card is presented to the reader can be adjusted according to the installation’s requirements. Option [3] by default. Enter Description [0] [1] [2] [3] [4] [5] [6] [7] Display on Card Read disabled Red Status LED flashes Green Status LED flashes Red and green Status LEDs flash Face Light flashes Face Light and red Status LED flash Face Light and green Status LED flash Face Light and both Status LEDs flash 8 Installation and Operating Instructions SECTION [005] KEYPAD LOCKOUT When Keypad Lockout is enabled and the Installer Code is entered incorrectly 3 consecutive times, the keypad ignores all entries for 60 seconds. Option [0] by default. Enter Description [0] [1] Keypad Lockout disabled Keypad Lockout enabled SECTION [101] BUZZER SETTING The number of beep tones emitted as a response to a card being presented to the reader can be adjusted from 0 (disabled) to 7 (7 rapid beep tones). Option [3] by default. SECTION [102] FACE LIGHT INTENSITY The Face Light’s illumination can be adjusted according to the installation’s requirements from 0 (extinguished) to 8 (brightest). Option [4] by default. SECTION [103] FACE LIGHT OPERATION The Face Light can be set to remain illuminated continually or can follow the state of the Status LEDs. Option [1] by default. Enter Description [0] [1] Face Light constant Face Light follows Status LEDs PosiPin 9 SECTION [104] FACE LIGHT COLOUR The Face Light’s colour can be modified as desired. Option [0] by default. This feature only applies when Face Light Operation programmed in Section [103] is set for Option [0]: Face Light constant. Enter Description [0] [1] Red (for CR-R885-S) or Blue (for CR-R885-SB) Face Light Green Face Light SECTION [200] CHANGING THE INSTALLER CODE The Installer Code (000000 by default) is used to program all the system’s sections, but cannot program the Master and User Codes (see page 11). In section [200] enter six digits where each digit can be any value from 0 to 9. RESETTING THE INSTALLER AND MASTER CODES TO DEFAULT To reset the Installer Code, Master Code 1 and Master Code 2 to factory defaults, disconnect the reader’s power supply. Press and hold the [3] and [4] keys simultaneously while re-connecting its power supply. Installer Code, Master Code 1 and Master Code 2 are reset when the reader emits a confirmation beep. 10 Installation and Operating Instructions MASTER PROGRAMMING Master Programming Mode is used to program Master and User Codes. SECTIONS [201] AND [202] CHANGING THE MASTER CODES Master Code 1 (default: 111111) is used to program both Master Codes, the User Codes and the Section [002] Door Lock Control (see page 7). Master Code 2 (default: 222222) can program the User Codes and change its own PIN. Master Code 2 cannot program Master Code 1 or the Door Lock Control. In the desired section enter the 6-digit personal identification number (PIN) where each digit can be any value from 0 to 9. To change the Master Codes: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter [MASTER CODE 1 or MASTER CODE 2] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash simultaneously. 3. Enter [201] to change Master Code 1 or [202] to change Master Code 2 and press the [ENTER] key. Reader emits a confirmation beep and the green LED becomes constant. 4. Enter the new PIN and press the [ENTER] key. The reader emits a confirmation beep and the green LED flashes. 5. To exit, press and hold the [CLEAR] key for 4 seconds. The reader emits a rejection beep and the green LED extinguishes. SECTION [203] USER CODE PROGRAMMING Master Code 1 and 2 can activate cards and program the personal identification numbers (PIN) for the User Codes. PosiPin includes 1000 User Codes. User Code 000 to 999 can be 1 to 8 digits in length where PosiPin 11 each digit can be any value from 0 to 9. You can use the table on page 17 to record the User Codes. To program User Codes: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter [MASTER CODE 1 or MASTER CODE 2] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash simultaneously. 3. Enter [203] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash alternately. 4. Enter the User Code number from 000 to 999. Press the [ENTER] key. The reader emits a confirmation beep and the green LED illuminates. If the red LED illuminates, the section is empty. If the red LED stays extinguished, a User Code is already programmed in the section. 5. Program the card and/or code depending on the Card/Code Option selected (see page 6). If Reader Only or Keypad Only are enabled, present the card to the reader or enter the PIN. If Keypad and Reader are enabled, first present the card to the reader and then enter the PIN. Press the [ENTER] key. The reader emits a confirmation beep and advances to the next section. 6. To program another section, repeat step 5. To exit, press and hold the [CLEAR] key for 4 seconds. When you press the [CLEAR] key in step 5: If the section is not programmed, PosiPin will exit the section and revert to step 4. If a card was entered or a key was pressed, PosiPin will delete the information and remain in the section. You can then enter a new card or PIN. 12 Installation and Operating Instructions DELETING A USER CODE User Codes can be deleted individually. When the User Code is deleted, a new card and/or PIN can be programmed in the section. To delete User Codes: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter [MASTER CODE 1 or MASTER CODE 2] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash simultaneously. 3. Enter [203] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash alternately. 4. Enter the section of the desired User Code. Press the [ENTER] key. The reader emits a confirmation beep and the green LED illuminates. If the red LED illuminates, the section is empty. If the red LED remains extinguished, a User Code is already programmed in the section. 5. Press the [CLEAR] key. The red LED flashes. 6. Press the [ENTER] key to delete the section’s programming and advance to the next section. Press the [CLEAR] key to exit the section without deleting the programming. 7. Press and hold the [CLEAR] key for 4 seconds to exit. PosiPin 13 SECTION [204] USER CODE RESET User Code Reset is used to delete all the User Codes (from User Code 000 to 999). To reset all User Codes: 1. Press and hold the [CLEAR] key for 4 seconds. The reader emits a confirmation beep, the green LED illuminates and the red LED extinguishes. 2. Enter [MASTER CODE 1 or MASTER CODE 2] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash simultaneously. 3. Enter [204] and press the [ENTER] key. Reader emits a confirmation beep and the red and the green LEDs flash alternately. 4. Press the [1] key and then press the [ENTER] key to confirm the reset. The reader emits a confirmation beep when the User Codes are deleted. When the User Codes are reset, it may require several seconds for the system to update the programming. The reader emits a confirmation beep once the modification is complete. 14 Installation and Operating Instructions USER OPERATION USER ACCESS Access is granted according to the Card/Code Option (see page 6) and the Access Granted Option set (see page 7). Single Access Granted Reader 1 user: user presents a valid card to the reader. Only Dual Access Granted 2 users: each user presents a valid card to the reader. Keypad 1 user: user enters a valid User 2 users: each user in turn enters a valid User Code on the Code on the keypad and Only keypad and presses the presses the [ENTER] key. [ENTER] key. 2 users: the first user presents Reader 1 user: user presents a valid card to the reader. The reader a valid card to the reader. The and Keypad emits a confirmation beep and reader emits a confirmation the green Status LED flashes. beep and the green Status LED flashes. The first user must User must enter a valid User Code on the keypad and press enter a valid User Code on the keypad and press the [ENTER] the [ENTER] key within 10 seconds. key within 10 seconds. The reader will emit a Confirmation Beep and the red Status LED flashes slowly. The second user has 30 seconds to present a valid card to the reader and then enter a valid User Code. The second user’s card and/or User Code must be different from the first. PosiPin 15 PANIC ALARM A panic alarm can be generated by pressing and holding the [CLEAR] and [ENTER] keys for 2 seconds. The Panic Alarm will activate the panic output (see page 4). Access will not be granted to users until the Panic alarm is disarmed. Disarming a Panic Alarm depends on the Card/Code Option (see page 6) and Access Granted Option (see page 7). To disarm a Panic Alarm: Single Access Granted Reader Only Dual Access Dual Access Granted with Granted Dual Panic Disarm present 1 valid card to the reader 2 users: each user presents a valid card to the reader. 2 users: each user enters a valid User Code and presses the [ENTER] key. 2 users: the first user presents Reader a valid card to the reader. then and must enter a valid User Code Keypad present 1 valid card to the and press the [ENTER] key. reader then enter 1 valid User The second user has 30 Code and press the [ENTER] key seconds to present a valid card to the reader and then enter a valid User Code. Keypad Only enter 1 valid User Code and press the [ENTER] key The second user’s card and/or User Code must be different from the first. 16 Installation and Operating Instructions USER CODE TABLE Use this table to keep a record of the User Codes. If you require extra pages, photocopy this table. The PIN column is provided for your convenience, however, we recommend not using it for security reasons. User Name Code For example: 000 John Doe Card Number PIN (optional) 0123456789 12345678 PosiPin 17 User Code Name 18 Installation and Operating Instructions Card Number PIN (optional) WARRANTY The Seller warrants its products to be free from defects in materials and workmanship under normal use for a period of two years. Except as specifically stated herein, all express or implied warranties whatsoever, statutory or otherwise, including without limitation, any implied warranty of merchantability and fitness for a particular purpose, are expressly excluded. Because Seller does not install or connect the products and because the products may be used in conjunction with products not manufactured by Seller, Seller cannot guarantee the performance of the security system. Seller obligation and liability under this warranty is expressly limited to repairing or replacing, at Seller's option, any product not meeting the specifications. In no event shall the Seller be liable to the buyer or any other person for any loss or damages whether direct or indirect, consequential or incidental, including without limitation any damages for lost profits stolen goods or claims by any other party caused by defective goods or otherwise arising from the improper, incorrect or otherwise faulty installation or use of the merchandise sold. NOTES Printed in Canada 08/2001 SPINEI-00
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.2 Linearized : No Create Date : 2001:08:15 14:56:42 Producer : Acrobat Distiller 4.0 for Windows Modify Date : 2001:08:15 14:56:45-04:00 Page Count : 23EXIF Metadata provided by EXIF.tools