Powertech Co R9P016 ZigBee Tracking Energy Monitor User Manual Monitor Socket Strip CT 20120903

Powertech Industrial Co Ltd ZigBee Tracking Energy Monitor Monitor Socket Strip CT 20120903

User Manual

GREEN POWERLINKZIGBEE IN-HOME ENERGY MONITOR SOLUTIONUser Manual© Copyright 2012The information contained herein is subject to change without notice.This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent.Feb. 2012All Versions
TABLE OF CONTENTSINTRODUCTION -----------------------------------------------------------   2HARDWARE FEATURES ---------------------------------------------------  3INSTALLATION -----------------------------------------------------------  5 Wireless Setup Range -------------------------------------------------  5 Install Smart Socket ---------------------------------------------------  5 Install Smart Power Strip----------------------------------------------  6 Install CT Smart Meter in the circuit breaker panel---------------------  7           Prepare the electrical circuit breaker-----------------------------  8           Connect the CT clamps & voltage wires                to the current & voltage input terminals----------------------------- 9            Wiring Diagram---------------------------------------------------  10INITIAL SETUP------------------------------------------------------------  12    Install Battery in Energy Monitor---------------------------------------  12    Use an AC/DC Adapter (Included)---------------------------------------  12  Wall Mount the Energy Monitor-----------------------------------------  12    Perform Energy Monitor Initial Setup-----------------------------------  13           Currency and Electricity Setup------------------------------------  13           Carbon Emission Setup--------------------------------------------- 14OPERATION---------------------------------------------------------------  15 Initial Smart Metering Devices and Energy Monitor pair up-------------  15 Energy Monitor Display and Control-------------------------------------  15    Change channels on the energy monitor---------------------------  16    Turn ON/OFF the outlet of the smart socket-----------------------  16   View real time and projection energy consumption----------------  17    View Real Time energy information for the channel---------------  17    View projection energy information for the selected channel------  18    View accumulation energy consumption---------------------------  19    Activate the energy accumulation mode for the selected channel--  19    View total day energy accumulation for the selected channel------  20    View total month energy accumulation for the selected channel---  21    View total year energy accumulation for the selected channel-----  22    Exit energy accumulation mode for the selected channel----------  23Reset the Energy Monitor to Factory Default------------------------------  23Powerlink Essential Energy Monitor User Manual V1.01
INTRODUCTIONThank you for purchasing the GREEN POWERLINK Energy Saving Solution, an innovative product which is designed to manage home electricity usage efficiently and reduce home electricity bill.In an effort to reduce your electricity bills, why not first check out what appliance uses most energy in your home.The New GREEN POWERLINK Energy Monitor allows you to take control of home electricity usage while saving you money in the process.With GREEN POWERLINK, you can see how much electricity you are using and with greater awareness you’ll become more energy efficient. Fully educated with the critical energy information, you are naturally motivated to adopt new energy saving habits and reduce harmful carbon emission for our environment.The GREEN POWERLINK is the total solution for green inspiration, energy conservation, and surge protection for your everyday life.Powerlink Essential Energy Monitor User Manual V1.02Powerlink Essential Energy Monitor User Manual V1.03HARDWARE FEATURESZigBee Tracking Energy Monitor ZigBee Tracking Smart Socket*Link up to 9 PowerLink    energy tracking devices*ZigBee Link: 2.4GHz (IEEE 802.15.4)*Transmission Time: 6 seconds*Wireless Range: 100 ft in open area*ZigBee Function: Router*ZigBee Profile: Smart Energy 1.0*ZigBee Cluster: Simple Metering*Green Surge Protected LED Indicator*Manual ON/OFF Button w/    Green LED Indicator*Security: AES 128 bits (Optional)*Meet IEC 62053‐21 class I    standard (1~1.5%)*Surge Protected Outlet*180J Surge ProtectionR9P0160000 R9P136A600*ZigBee Link: 2.4GHz (IEEE 802.15.4)*Wireless Range: 100 ft in open area*Display instant energy consum    ption in Watts, Cost, CO2*Display forecasted energy usage in    KWH, Cost, CO2 by day/month/year*Display accumulated energy usage    by day/month/year*Surge counter displays the    frequency of surge occurrences*Energy Display Power Supply :    9V AC/DC adaptor (included)
INSTALLATIONWireless Setup RangeThe energy monitor and smart socket/strip/CT meter communicate with wireless technology. To ensure the communication with no interruption, please locate and setup energy monitor, smart socket/strip/CT meter within 100 Ft of range.Install Smart SocketThe single outlet smart socket allows the user to track electricity consumption of individual home appliance and protect it against surge and voltage spikes.1. Plug in the smart socket to a powered AC outlet.2. Plug in the appliance into the smart socket outlet.3. The outlet power can be manually turned ON/OFF by pressing the “Manual ON/OFF” button on the smart socket. You may also control the outlet power remotely by using the energy monitor (see the operation instruction).4. Perform initial energy monitor and smart socket pair up (see the operation      instruction).Powerlink Essential Energy Monitor User Manual V1.04Powerlink Essential Energy Monitor User Manual V1.05ZigBee Tracking Smart Meter*6 Surge Protected Outlets*540J Surge Protection*Green Surge Protected LED    Indicator*Red Grounded Fault LED Indicator*Transmission Time: 6 seconds*ZigBee Function: Router*ZigBee Cluster: Simple Metering*Manual ON/OFF Button w/     Green LED Indicator*Meet IEC 62053‐21 class I    standard (1~1.5%)*ZigBee Link: 2.4GHz (IEEE 802.15.4)*Wireless Range: 100 ft in open area*ZigBee Profile: Smart Energy 1.0*Security: AES 128 bits (Optional)*Transmission Time: 6 seconds*ZigBee Function: Router*ZigBee Cluster: Simple Metering*Installation type: 1‐phase & 3‐wire*CT Meter Input Voltage:100~240V*CT Meter Input Current: 60A*CT Meter Frequency: 50/60Hz*CT Meter Accuracy: <1% at PF=1*Power Supply: Power acquired    from electrical meterR9P624NI00 M9PC020000ZigBee Tracking Smart Strip
Install Smart Power StripThe smart power strip allows the user to track electricity consumption of group home appliances in the same area and protect it against surge and voltage spikes.1. Plug in the smart power strip to a powered AC outlet.2. Plug in the appliances into the smart power strip outlets.3. The Energy Saver outlets on the power strip can be manually turned  ON/OFF by     pressing the “Manual ON/OFF” button on the power strip. You may also control     the energy saver outlets remotely by using the energy monitor (see the     operation instruction).4. Perform initial energy monitor and smart power strip pair up (see the         operation instruction).Powerlink Essential Energy Monitor User Manual V1.06Powerlink Essential Energy Monitor User Manual V1.07PROTECTED LED LIGHTThis LED light illuminatesto indicate that the surgeprotection is active andprotecting equipmentsfrom power surges.Manual ON/OFF”buttonManual ON/OFF”buttonPROTECTED LED LIGHTThis LED light illuminatesto indicate that the surgeprotection is active andprotecting equipmentsfrom power surges.GROUNDED LED LIGHTThis LED light illuminates to indicate that the surgeprotector is plugged into aproperly grounded outlet.ALWAYS ON OUTLETSare also available fordevices which are alwayskept on and needcontinuous power.
Powerlink Essential Energy Monitor User Manual V1.08Powerlink Essential Energy Monitor User Manual V1.09Install CT Smart Meter in the circuit breaker panelThe CT smart meter allows the user to measure entire electricity power consumption from electrical panel.  CautionYour safety is very important to us. Please read these cautions regarding the installation of your CT Smart Meter.• Electrical panel contains live electrical wires and components even when the     main circuit breaker has been switched off. Do not attempt any installation     unless you are familiar where these electrified areas are.• Any work on or near electrical panel could induce danger or fatal electrical     shock. It is highly recommended that all work should be done only by qualified     electricians or certified electrical specialist.Prepare the electrical circuit breakerWARNING: • Before you start, you must turn off all power in the electrical circuit breaker     by turning off the main breaker or main switch.• Some wires and components could still be live even when the main breaker      or switch is turned off. Please indentify these wires and components before     installation and pay attention to these areas at all time.1. Turn off all power by turning off the main breaker or main switch.2. Remove the cover of electricity circuit breaker panel. Connect the CT clamps & voltage wires to the current & voltage input terminalsBefore installation, please connect the CT clamp wires to the current input terminal following the sequence 1S(red) 1L(black) 2S(red) 2L(black). Then connect the voltage wires to the voltage input terminal following the sequence L(red) N(black).At the bottom of the current transformer, there is “K→L” indication mark.Before you clip on the CT over the power line, please make sure the powercurrent flow direction follow the “K→L” indication mark on the CTK LBotton view
Powerlink Essential Energy Monitor User Manual V1.010Powerlink Essential Energy Monitor User Manual V1.011Wiring DiagramRefer to the following wiring diagram and dial the mode switch that matches your electrical panel type. Then install CT clamp over the power line and voltage wires to L and N voltage terminals.Once the CT smart meter is installed in the electrical panel, turn on the main breaker and perform initial energy monitor and CT smart meter pair up (see the operation instruction).  1 Phase & 2 Wire – 1CT1 Phase & 3 Wire – 2CT
Powerlink Essential Energy Monitor User Manual V1.012Powerlink Essential Energy Monitor User Manual V1.013INITIAL SETUPInstall Battery in Energy MonitorOpen the battery compartment on the back of the energy monitor and install 4 x AA 1.5V alkaline batteries with right polarity.Warning: Reversing the polarity may damage the product.Once batteries are installed, the energy monitor will turn on and enter initial setup mode. Please proceed and refer to the next instruction for initial setup.Note: Batteries are not included in the product kit.Please do not mix and match different types / new & old batteries in use with the energy monitor.Use an AC/DC Adapter (Included)The energy monitor can operate with the included 9V AC/DC adapter.When the AC/DC adaptor is used in conjunction with batteries installed, the energy monitor will be powered by the AC/DC adaptor to save batteries life in the energy monitor.Wall Mount the Energy Monitor1. Select a spot within the wireless range to mount the supplied wall bracket for     the energy monitor.2. The ideal locations for the energy monitor wall mount are entrance of a room or     location where the energy monitor can be easily seem and accessed.3. Use adhesive tape or supplied screws to securely attach the supplied wall     bracket to a wall.Perform Energy Monitor Initial SetupPerform the following initial setup steps for first time operation1. Currency and Electricity Rate Setup2. Carbon Emission SetupNote: During anytime, you may press the SET button for 3 seconds to enter setup mode and change currency, electricity rate, and carbon emission rate.Currency and Electricity SetupThere are more than 4,000 electric utilities across the US and Canada. In the event your local utility uses a tariff calculation other than flat electricity rate, please key in the average rate that most nearly resembles your utility’s tariff schedule.1. The $ symbol blinks first. Use the arrow key to     select currency symbol in $ /€ /£.2. Press the SET button to proceed to Electricity     Utility Rate setup.3. The electricity rate value blinks. Use the arrow     key to change the rate value.4. Press the SET button to proceed to Carbon     Emission setup.    Note: The default Currency is US dollar and     default Electricity rate is 0.12¢per     KWH.
Powerlink Essential Energy Monitor User Manual V1.014Powerlink Essential Energy Monitor User Manual V1.015Carbon Emission SetupCarbon dioxide is emitted in the process of producing electricity by burning coal & fossil fuel. This is usually referred to CO2 footprint or carbon emission, which in turn has contributed global warming and caused abnormal weather. The average carbon emission rate is 0.49Kg (1.08 lbs) of carbon emission for every 1 KWH of electricity produced. This can be changed depending upon your local electric utility. Please contact your local utility for carbon emission rate.OPERATIONInitial Smart Metering Devices and Energy Monitor pair upThe learning function allows you to expand more smart socket/strip/CT meter later on. You may purchase more compatible smart metering devices and pair up to 9 smart metering devices to the energy monitor.1. When pairing up smart metering devices and energy monitor, please bring     energy monitor close to the smart metering devices.2. On the energy monitor, use the arrow key to select from channel 1 to 9     which you wish to add the smart metering devices. 3. On the smart metering devices, press and hold the LEARNING button until     the LED indicator light flashes then release the button.4. Press the learning button on top of the energy monitor until it beeps once to     confirm the smart socket and energy monitor has been successfully paired     up.5. If you hear 3 beeps buzzer from the energy monitor, this indicates the smart     metering devices and energy monitor has not been successfully paired up.     Please follow step3 to step5 to redo the pair up procedures.6. Repeat step2 to step5 to add more smart metering devices to different     channel on the energy monitor.Energy Monitor Display and ControlThe user friendly energy monitor allows user to browse energy information and control smart socket and strip remotely.Discover home energy use by viewing real time, projection and accumulation energy information in Watts, KWH, Cost, and Carbon emission. Save money by adopting new energy saving habits and eliminating standby power waste. 1. The Kg symbol blinks first. Use the arrow key to     select the weight symbol in Kg  or LB. Then press     the SET button to proceed to carbon emission rate     setup.2. The carbon emission rate blinks. Use the arrow     key to change the value. Press the SET button to     finish initial setup.    Note: The default Carbon emission rate is 0.49Kg     of carbon emission for every 1KWH of electricity     produced.
Powerlink Essential Energy Monitor User Manual V1.016Powerlink Essential Energy Monitor User Manual V1.017View real time and projection energy consumptionView Real Time energy information for the channelThe energy monitor provides real time and projection energy information. Press the MODE button to scroll thru different energy information display.In Real Time Mode, the energy monitor will display instant energy consumption in Watts, energy cost in $/hr, and carbon emission in Kg/hr.Change channels on the energy monitorTurn ON/OFF the outlet of the smart socketThe energy monitor can monitor and control up to 9 smart metering devices. On the energy monitor, each CH number represents a smart metering device.Press the arrow key to change the channel from CH1 to CH9 to ALL channels. The energy monitor will not display energy information when the selected channel does not exit.When you select “ALL” channels, the energy monitor will display the sum total energy information of all available Channels.The energy monitor can display the ON/OFF Status of the energy saver outlets on the surge protector. To avoid turning on or off the energy saver outlets by accident, the ON/OFF function can only be accessed in real time mode.In real time mode, use the ON/OFF Key on the energy monitor to turn ON and OFF the energy saver outlets of the surge protector.Real Time Daily Projection Monthly Projection Yearly Projection→→→ →
Powerlink Essential Energy Monitor User Manual V1.018Powerlink Essential Energy Monitor User Manual V1.019View projection energy information for the selected channelThe energy monitor reads your device energy usage continuously while your device is on and off, and calculates the projection energy information base on real time and historical measurements.We suggest let the energy monitor measure device several typical use cycles, and the projection energy information will be more accurate.In Projection Mode, the energy monitor will display energy consumption in KWH, energy cost in $, and carbon emission in Kg.Use the MODE key to change from daily / monthly / yearly projection energy information.View accumulation energy consumptionThe energy monitor provides energy usage accumulation display. This allows you to view total accumulation energy usage in day, month and year for each channel.Activate the energy accumulation mode for the selected channel1. Select the channel you wish to acquire      energy usage accumulation. You can     active the energy usage accumulation for     each channel in different time.2. In DAY mode, press the MODE button 3     seconds to activate the energy accumula    tion mode.DAY MONTH YEARDAY
Powerlink Essential Energy Monitor User Manual V1.020Powerlink Essential Energy Monitor User Manual V1.021View total day energy accumulation for the selected channelIn daily accumulation mode, the energy monitor will display the total accumulative energy information for the total duration days since accumulation mode is activated.1. The energy monitor will first display DAY01 for 3 seconds, then display the total     energy accumulation data for 10 seconds in repeat cycle. 2. After 24 hours, the energy accumulation display will advance to DAY 02 and     display the total energy accumulation data.Note: the plug icon flashes repeatedly as an accumulation mode indicatorView total month energy accumulation for the selected channelIn monthly accumulation mode, the energy monitor will display the total accumulative energy information for the total duration months since accumulation mode is activated.1. When the total energy usage accumulates over 30 days, it will move and     store the total energy accumulation data in MONTH database, and the DAY     accumulation data will be reset and re-accumulated.2. Press the MODE button to switch and view the total energy usage     accumulation for the past duration days and months.DAY DAY DAY DAYDAYDAY
Powerlink Essential Energy Monitor User Manual V1.022Powerlink Essential Energy Monitor User Manual V1.023View total year energy accumulation for the selected channelIn yearly accumulation mode, the energy monitor will display the total accumula-tive energy information for the total duration years since accumulation mode is activated.1. When the total energy usage accumulates over 12 months, it will move and     store the total energy accumulation data in YEAR database, and the MONTH     accumulation data will be reset and re-accumulated.2. Press the MODE button to switch and view the total energy usage accumulation     for the past duration days / months / years.Exit energy accumulation mode for the selected channel1. In DAY accumulation mode, press the MODE button 3 seconds to exit the     accumulation mode to projection mode.2. The energy usage will still be accumulated and stored in device’s database.Reset the Energy Monitor to Factory DefaultPlease follow the instruction below to reset the energy monitor to its factory default setting.Note:By performing resetting energy monitor to factory default, all saved data, setup & channel settings will be erased. 1. Locate the reset point on top of the energy monitor.2. Push a stylus or pen into the reset point for 5 seconds.3. The energy monitor will be hard reset to factory default setting. Please     perform all the necessary setup and channel setting.MONTH YEAR
Powerlink Essential Energy Monitor User Manual V1.024                   CAUTION:To assure continued FCC compliance:Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment.!   FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT  This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if   not installed and  used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  --  Reorient or relocate the receiving antenna. --  Increase the separation between the equipment and receiver. --  Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. --  Consult the dealer or an experienced radio/TV technician for help.  CAUTION:  To assure continued FCC compliance:   Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment.    FCC Label Compliance Statement: This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.  Exposure to Radio Frequency Radiation: To comply with FCC RF exposure compliance requirements, a separation distance of at least 20cm must be maintained between the antenna of this device and all persons. This device must not be co-located or operating in conjunction with any other antenna or transmitter.     若有附SAR報告則無此警語 產品小於8*10cm就要寫在手冊內警語