Powertech Co R9P016 ZigBee Tracking Energy Monitor User Manual Monitor Socket Strip CT 20120903
Powertech Industrial Co Ltd ZigBee Tracking Energy Monitor Monitor Socket Strip CT 20120903
User Manual
GREEN POWERLINK ZIGBEE IN-HOME ENERGY MONITOR SOLUTION User Manual © Copyright 2012 The information contained herein is subject to change without notice. This document contains proprietary information, which is protected by copyright. No part of this document may be photocopied, reproduced, or translated into another language without the prior written consent. Feb. 2012 All Versions TABLE OF CONTENTS INTRODUCTION ----------------------------------------------------------HARDWARE FEATURES --------------------------------------------------INSTALLATION ----------------------------------------------------------Wireless Setup Range ------------------------------------------------Install Smart Socket --------------------------------------------------Install Smart Power Strip---------------------------------------------Install CT Smart Meter in the circuit breaker panel--------------------Prepare the electrical circuit breaker----------------------------Connect the CT clamps & voltage wires to the current & voltage input terminals----------------------------Wiring Diagram--------------------------------------------------INITIAL SETUP-----------------------------------------------------------Install Battery in Energy Monitor--------------------------------------Use an AC/DC Adapter (Included)--------------------------------------Wall Mount the Energy Monitor----------------------------------------Perform Energy Monitor Initial Setup----------------------------------Currency and Electricity Setup-----------------------------------Carbon Emission Setup--------------------------------------------OPERATION--------------------------------------------------------------Initial Smart Metering Devices and Energy Monitor pair up------------Energy Monitor Display and Control------------------------------------Change channels on the energy monitor--------------------------Turn ON/OFF the outlet of the smart socket----------------------View real time and projection energy consumption---------------View Real Time energy information for the channel--------------View projection energy information for the selected channel-----View accumulation energy consumption--------------------------Activate the energy accumulation mode for the selected channel-View total day energy accumulation for the selected channel-----View total month energy accumulation for the selected channel--View total year energy accumulation for the selected channel----Exit energy accumulation mode for the selected channel---------Reset the Energy Monitor to Factory Default------------------------------ 10 12 12 12 12 13 13 14 15 15 15 16 16 17 17 18 19 19 20 21 22 23 23 Powerlink Essential Energy Monitor User Manual V1.0 INTRODUCTION HARDWARE FEATURES Thank you for purchasing the GREEN POWERLINK Energy Saving Solution, an ZigBee Tracking Energy Monitor innovative product which is designed to manage home electricity usage efficiently ZigBee Tracking Smart Socket R9P0160000 and reduce home electricity bill. R9P136A600 In an effort to reduce your electricity bills, why not first check out what appliance uses most energy in your home. The New GREEN POWERLINK Energy Monitor allows you to take control of home electricity usage while saving you money in the process. With GREEN POWERLINK, you can see how much electricity you are using and *Surge Protected Outlet *Link up to 9 PowerLink with greater awareness you’ll become more energy efficient. *180J Surge Protection energy tracking devices Fully educated with the critical energy information, you are naturally motivated to adopt new energy saving habits and reduce harmful carbon emission for our environment. The GREEN POWERLINK is the total solution for green inspiration, energy conservation, and surge protection for your everyday life. *ZigBee Link: 2.4GHz (IEEE 802.15.4) *ZigBee Link: 2.4GHz (IEEE 802.15.4) *Wireless Range: 100 ft in open area *Transmission Time: 6 seconds *Display instant energy consum *Wireless Range: 100 ft in open area *ZigBee Function: Router ption in Watts, Cost, CO2 *Display forecasted energy usage in *ZigBee Profile: Smart Energy 1.0 KWH, Cost, CO2 by day/month/year *ZigBee Cluster: Simple Metering *Display accumulated energy usage Green LED Indicator *Surge counter displays the frequency of surge occurrences *Energy Display Power Supply : 9V AC/DC adaptor (included) Powerlink Essential Energy Monitor User Manual V1.0 *Green Surge Protected LED Indicator *Manual ON/OFF Button w/ by day/month/year *Security: AES 128 bits (Optional) *Meet IEC 62053‐21 class I standard (1~1.5%) Powerlink Essential Energy Monitor User Manual V1.0 ZigBee Tracking Smart Strip INSTALLATION ZigBee Tracking Smart Meter R9P624NI00 M9PC020000 Wireless Setup Range The energy monitor and smart socket/strip/CT meter communicate with wireless technology. To ensure the communication with no interruption, please locate and setup energy monitor, smart socket/strip/CT meter within 100 Ft of range. *6 Surge Protected Outlets *Transmission Time: 6 seconds *540J Surge Protection *ZigBee Function: Router *Green Surge Protected LED *ZigBee Cluster: Simple Metering Install Smart Socket *Installation type: 1‐phase & 3‐wire Indicator The single outlet smart socket allows the user to track electricity consumption *Red Grounded Fault LED Indicator *CT Meter Input Voltage:100~240V *Transmission Time: 6 seconds *CT Meter Input Current: 60A *ZigBee Function: Router *CT Meter Frequency: 50/60Hz *ZigBee Cluster: Simple Metering *CT Meter Accuracy: <1% at PF=1 1. Plug in the smart socket to a powered AC outlet. *Manual ON/OFF Button w/ *Power Supply: Power acquired 2. Plug in the appliance into the smart socket outlet. of individual home appliance and protect it against surge and voltage spikes. 3. The outlet power can be manually turned ON/OFF by pressing the “Manual from electrical meter Green LED Indicator ON/OFF” button on the smart socket. You may also control the outlet power *Meet IEC 62053‐21 class I standard (1~1.5%) remotely by using the energy monitor (see the operation instruction). 4. Perform initial energy monitor and smart socket pair up (see the operation *ZigBee Link: 2.4GHz (IEEE 802.15.4) instruction). *Wireless Range: 100 ft in open area *ZigBee Profile: Smart Energy 1.0 *Security: AES 128 bits (Optional) Powerlink Essential Energy Monitor User Manual V1.0 Powerlink Essential Energy Monitor User Manual V1.0 PROTECTED LED LIGHT This LED light illuminates to indicate that the surge protection is active and protecting equipments from power surges. PROTECTED LED LIGHT This LED light illuminates to indicate that the surge protection is active and protecting equipments from power surges. Manual ON/OFF” button GROUNDED LED LIGHT This LED light illuminates to indicate that the surge protector is plugged into a properly grounded outlet. Manual ON/OFF” button ALWAYS ON OUTLETS Install Smart Power Strip are also available for devices which are always kept on and need continuous power. The smart power strip allows the user to track electricity consumption of group home appliances in the same area and protect it against surge and voltage spikes. 1. Plug in the smart power strip to a powered AC outlet. 2. Plug in the appliances into the smart power strip outlets. 3. The Energy Saver outlets on the power strip can be manually turned ON/OFF by pressing the “Manual ON/OFF” button on the power strip. You may also control the energy saver outlets remotely by using the energy monitor (see the operation instruction). 4. Perform initial energy monitor and smart power strip pair up (see the operation instruction). Powerlink Essential Energy Monitor User Manual V1.0 Powerlink Essential Energy Monitor User Manual V1.0 Install CT Smart Meter in the circuit breaker panel Connect the CT clamps & voltage wires to the current & voltage input terminals The CT smart meter allows the user to measure entire electricity power Before installation, please connect the CT clamp wires to the current input terminal following the sequence 1S(red) 1L(black) 2S(red) 2L(black). Then connect the voltage wires to the voltage input terminal following the sequence L(red) N(black). consumption from electrical panel. Caution Your safety is very important to us. Please read these cautions regarding the installation of your CT Smart Meter. • Electrical panel contains live electrical wires and components even when the main circuit breaker has been switched off. Do not attempt any installation At the bottom of the current transformer, unless you are familiar where these electrified areas are. there is “K→L” indication mark. • Any work on or near electrical panel could induce danger or fatal electrical shock. It is highly recommended that all work should be done only by qualified electricians or certified electrical specialist. Before you clip on the CT over the power line, please make sure the power current flow direction follow the “K→L” indication mark on the CT Prepare the electrical circuit breaker WARNING: • Before you start, you must turn off all power in the electrical circuit breaker by turning off the main breaker or main switch. • Some wires and components could still be live even when the main breaker or switch is turned off. Please indentify these wires and components before installation and pay attention to these areas at all time. Botton view 1. Turn off all power by turning off the main breaker or main switch. 2. Remove the cover of electricity circuit breaker panel. Powerlink Essential Energy Monitor User Manual V1.0 Powerlink Essential Energy Monitor User Manual V1.0 Wiring Diagram 1 Phase & 3 Wire – 2CT Refer to the following wiring diagram and dial the mode switch that matches your electrical panel type. Then install CT clamp over the power line and voltage wires to L and N voltage terminals. Once the CT smart meter is installed in the electrical panel, turn on the main breaker and perform initial energy monitor and CT smart meter pair up (see the operation instruction). 1 Phase & 2 Wire – 1CT Powerlink Essential Energy Monitor User Manual V1.0 10 Powerlink Essential Energy Monitor User Manual V1.0 11 INITIAL SETUP Perform Energy Monitor Initial Setup Perform the following initial setup steps for first time operation 1. Currency and Electricity Rate Setup Install Battery in Energy Monitor 2. Carbon Emission Setup Open the battery compartment on the back of the energy monitor and install 4 x AA 1.5V alkaline batteries with right polarity. Note: During anytime, you may press the SET button for 3 seconds to enter Warning: Reversing the polarity may damage the product. setup mode and change currency, electricity rate, and carbon emission rate. Once batteries are installed, the energy monitor will turn on and enter initial setup Currency and Electricity Setup mode. Please proceed and refer to the next instruction for initial setup. There are more than 4,000 electric utilities across the US and Canada. In the Note: event your local utility uses a tariff calculation other than flat electricity rate, Batteries are not included in the product kit. please key in the average rate that most nearly resembles your utility’s tariff Please do not mix and match different types / new & old batteries in use with the schedule. energy monitor. 1. The $ symbol blinks first. Use the arrow key to select currency symbol in $ /€ /£. Use an AC/DC Adapter (Included) 2. Press the SET button to proceed to Electricity The energy monitor can operate with the included 9V AC/DC adapter. Utility Rate setup. When the AC/DC adaptor is used in conjunction with batteries installed, the energy 3. The electricity rate value blinks. Use the arrow monitor will be powered by the AC/DC adaptor to save batteries life in the energy key to change the rate value. monitor. 4. Press the SET button to proceed to Carbon Wall Mount the Energy Monitor Emission setup. 1. Select a spot within the wireless range to mount the supplied wall bracket for Note: The default Currency is US dollar and the energy monitor. default Electricity rate is 0.12¢per 2. The ideal locations for the energy monitor wall mount are entrance of a room or KWH. location where the energy monitor can be easily seem and accessed. 3. Use adhesive tape or supplied screws to securely attach the supplied wall bracket to a wall. Powerlink Essential Energy Monitor User Manual V1.0 12 Powerlink Essential Energy Monitor User Manual V1.0 13 OPERATION Carbon Emission Setup Carbon dioxide is emitted in the process of producing electricity by burning coal & Initial Smart Metering Devices and Energy Monitor pair up fossil fuel. This is usually referred to CO2 footprint or carbon emission, which in turn has contributed global warming and caused abnormal weather. The learning function allows you to expand more smart socket/strip/CT meter The average carbon emission rate is 0.49Kg (1.08 lbs) of carbon emission for every later on. You may purchase more compatible smart metering devices and pair 1 KWH of electricity produced. This can be changed depending upon your local up to 9 smart metering devices to the energy monitor. electric utility. Please contact your local utility for carbon emission rate. 1. When pairing up smart metering devices and energy monitor, please bring 1. The Kg symbol blinks first. Use the arrow key to energy monitor close to the smart metering devices. select the weight symbol in Kg or LB. Then press 2. On the energy monitor, use the arrow key to select from channel 1 to 9 the SET button to proceed to carbon emission rate which you wish to add the smart metering devices. 3. On the smart metering devices, press and hold the LEARNING button until setup. the LED indicator light flashes then release the button. 2. The carbon emission rate blinks. Use the arrow 4. Press the learning button on top of the energy monitor until it beeps once to key to change the value. Press the SET button to confirm the smart socket and energy monitor has been successfully paired finish initial setup. up. 5. If you hear 3 beeps buzzer from the energy monitor, this indicates the smart Note: The default Carbon emission rate is 0.49Kg metering devices and energy monitor has not been successfully paired up. of carbon emission for every 1KWH of electricity Please follow step3 to step5 to redo the pair up procedures. produced. 6. Repeat step2 to step5 to add more smart metering devices to different channel on the energy monitor. Energy Monitor Display and Control The user friendly energy monitor allows user to browse energy information and control smart socket and strip remotely. Discover home energy use by viewing real time, projection and accumulation energy information in Watts, KWH, Cost, and Carbon emission. Save money by adopting new energy saving habits and eliminating standby power waste. Powerlink Essential Energy Monitor User Manual V1.0 14 Powerlink Essential Energy Monitor User Manual V1.0 15 Change channels on the energy monitor View real time and projection energy consumption The energy monitor can monitor and control The energy monitor provides real time and up to 9 smart metering devices. On the projection energy information. Press the energy monitor, each CH number MODE button to scroll thru different energy represents a smart metering device. information display. Press the arrow key to change the channel → Real Time → from CH1 to CH9 to ALL channels. The energy monitor will not display energy Daily Projection → → information when the selected channel does not exit. Monthly Projection When you select “ALL” channels, the energy monitor will display the sum total energy Yearly Projection information of all available Channels. View Real Time energy information for the channel Turn ON/OFF the outlet of the smart socket The energy monitor can display the ON/OFF In Real Time Mode, the energy monitor will Status of the energy saver outlets on the display instant energy consumption in surge protector. Watts, energy cost in $/hr, and carbon To avoid turning on or off the energy saver emission in Kg/hr. outlets by accident, the ON/OFF function can only be accessed in real time mode. In real time mode, use the ON/OFF Key on the energy monitor to turn ON and OFF the energy saver outlets of the surge protector. Powerlink Essential Energy Monitor User Manual V1.0 16 Powerlink Essential Energy Monitor User Manual V1.0 17 View projection energy information for the selected channel View accumulation energy consumption The energy monitor provides energy usage accumulation display. This allows DAY MONTH you to view total accumulation energy usage in day, month and year for each YEAR channel. Activate the energy accumulation mode for the selected channel 1. Select the channel you wish to acquire The energy monitor reads your device energy usage continuously while your device energy usage accumulation. You can is on and off, and calculates the projection energy information base on real time and historical measurements. DAY active the energy usage accumulation for each channel in different time. We suggest let the energy monitor measure device several typical use cycles, and 2. In DAY mode, press the MODE button 3 the projection energy information will be more accurate. In Projection Mode, the energy monitor will display energy consumption in KWH, seconds to activate the energy accumula energy cost in $, and carbon emission in Kg. tion mode. Use the MODE key to change from daily / monthly / yearly projection energy information. Powerlink Essential Energy Monitor User Manual V1.0 18 Powerlink Essential Energy Monitor User Manual V1.0 19 View total day energy accumulation for the selected channel View total month energy accumulation for the selected channel In daily accumulation mode, the energy monitor will display the total accumulative In monthly accumulation mode, the energy monitor will display the total energy information for the total duration days since accumulation mode is accumulative energy information for the total duration months since activated. accumulation mode is activated. DAY DAY DAY DAY DAY 1. The energy monitor will first display DAY01 for 3 seconds, then display the total DAY 1. When the total energy usage accumulates over 30 days, it will move and energy accumulation data for 10 seconds in repeat cycle. store the total energy accumulation data in MONTH database, and the DAY 2. After 24 hours, the energy accumulation display will advance to DAY 02 and accumulation data will be reset and re-accumulated. display the total energy accumulation data. 2. Press the MODE button to switch and view the total energy usage accumulation for the past duration days and months. Note: the plug icon flashes repeatedly as an accumulation mode indicator Powerlink Essential Energy Monitor User Manual V1.0 20 Powerlink Essential Energy Monitor User Manual V1.0 21 View total year energy accumulation for the selected channel Exit energy accumulation mode for the selected channel In yearly accumulation mode, the energy monitor will display the total accumula- 1. In DAY accumulation mode, press the MODE button 3 seconds to exit the accumulation mode to projection mode. tive energy information for the total duration years since accumulation mode is 2. The energy usage will still be accumulated and stored in device’s database. activated. MONTH YEAR Reset the Energy Monitor to Factory Default Please follow the instruction below to reset the energy monitor to its factory default setting. 1. When the total energy usage accumulates over 12 months, it will move and store the total energy accumulation data in YEAR database, and the MONTH Note: accumulation data will be reset and re-accumulated. By performing resetting energy monitor to factory default, all saved data, setup & channel settings will be erased. 2. Press the MODE button to switch and view the total energy usage accumulation for the past duration days / months / years. 1. Locate the reset point on top of the energy monitor. 2. Push a stylus or pen into the reset point for 5 seconds. 3. The energy monitor will be hard reset to factory default setting. Please perform all the necessary setup and channel setting. Powerlink Essential Energy Monitor User Manual V1.0 22 Powerlink Essential Energy Monitor User Manual V1.0 23 ! CAUTION: To assure continued FCC compliance: Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. FEDERAL COMMUNICATIONS COMMISSION INTERFERENCE STATEMENT This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: -- Reorient or relocate the receiving antenna. -- Increase the separation between the equipment and receiver. -- Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. -- Consult the dealer or an experienced radio/TV technician for help. CAUTION: To assure continued FCC compliance: Any changes or modifications not expressly approved by the grantee of this device could void the user's authority to operate the equipment. 產品小於8*10cm就要寫在手冊 24 Powerlink Essential Energy Monitor User Manual V1.0 內警語
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-702 Format : application/pdf Title : Monitor & Socket & Strip & CT-20120903 Creator Tool : Adobe Illustrator CS5.1 Create Date : 2012:09:03 16:15:24+08:00 Modify Date : 2012:09:05 11:57:08+08:00 Metadata Date : 2012:09:05 11:57:08+08:00 Thumbnail Width : 256 Thumbnail Height : 56 Thumbnail Format : JPEG Thumbnail Image : (Binary data 4463 bytes, use -b option to extract) Document ID : xmp.did:EE798742172068118083E395AA583615 Instance ID : uuid:c0301704-4964-43c9-905c-d41eab9c3ceb Original Document ID : uuid:801EF41CDEAF11DF924CD171F6479B81 Rendition Class : proof:pdf Derived From Instance ID : uuid:f69df8d8-cf42-d547-87ed-72c88d109d2c Derived From Document ID : xmp.did:414966981D2068118083CCE25350421E Derived From Original Document ID: uuid:801EF41CDEAF11DF924CD171F6479B81 Derived From Rendition Class : proof:pdf History Action : saved, saved, saved, saved, saved History Instance ID : xmp.iid:94A08A962F2068118083B73BE0020E3F, xmp.iid:F97F1174072068118C14C16D92274346, xmp.iid:08801174072068118083CCE25350421E, xmp.iid:414966981D2068118083CCE25350421E, xmp.iid:EE798742172068118083E395AA583615 History When : 2011:12:29 15:19:42+08:00, 2012:02:14 17:21:36+08:00, 2012:02:22 14:55:09+08:00, 2012:02:22 17:49:51+08:00, 2012:09:03 16:15:11+08:00 History Software Agent : Adobe Illustrator CS5.1, Adobe Illustrator CS5.1, Adobe Illustrator CS5.1, Adobe Illustrator CS5.1, Adobe Illustrator CS5.1 History Changed : /, /, /, /, / Manifest Link Form : EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference Manifest Reference File Path : /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee CT-2.psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee-6.psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/DSC_0121-strip..psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee-3.psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee-1.psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee-3.psd, /Users/olivea/Desktop/imac/ 中性包材設計/ 說明書/Zigbee_Monitor & Socket & Strip & CT 20120903/link/zigbee-3.psd Startup Profile : Basic CMYK N Pages : 1 Has Visible Transparency : True Has Visible Overprint : False Max Page Size W : 209.999929 Max Page Size H : 148.500152 Max Page Size Unit : Millimeters Font Name : ArialMT, Arial-BoldMT, MyriadPro-Regular, DIN-Regular, DIN-Medium, DIN-Bold, DIN-Black, DINOT-Bold, LiHeiPro, AdobeMingStd-Light, DFHei-Md Font Family : Arial, Arial, Myriad Pro, DIN, DIN, DIN, DIN, DINOT, 儷黑 Pro, Adobe 明體 Std, DFHei Md-HK-BF Font Face : Regular, Bold, Regular, Regular, Medium, Bold, Black, Bold, 中黑, L, Md-HK-BF Font Type : Open Type, Open Type, Open Type, Type 1, Type 1, Type 1, Type 1, Open Type, TrueType, Open Type, Unknown Font Version : Version 5.06, Version 5.06, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, 001.000, 003.130, 001.000, 001.000, Version 7.460;PS 7.046;hotconv 1.0.38, 6.0d4e1, Version 6.007;PS 6.001;hotconv 1.0.67;makeotf.lib2.5.33168, 7.0d17e1 Font Composite : False, False, False, False, False, False, False, False, False, False, False Font File Name : Arial.ttf, Arial Bold.ttf, MyriadPro-Regular.otf, DINReg; DIN-Regular, DINMed; DIN-Medium, DINBol; DIN-Bold, DINBla; DIN-Black, DINOT-Bold.otf, 儷黑 Pro.ttf, AdobeMingStd-Light.otf, STHeiti Light.ttc Plate Names : Cyan, Magenta, Yellow, Black, PANTONE Black C Swatch Groups Colorants Red : 59 Swatch Groups Colorants Green : 35 Swatch Groups Colorants Blue : 20 Swatch Groups Colorants Tint : 100.000000 Swatch Groups Colorants Cyan : 0.000000 Swatch Groups Colorants Magenta : 13.000000 Swatch Groups Colorants Yellow : 48.999996 Swatch Groups Colorants Black : 97.999992 Swatch Groups Group Name : Grayscale Swatch Groups Group Type : 1 Swatch Groups Colorants Swatch Name: K=5 Swatch Groups Colorants Mode : GRAY Swatch Groups Colorants Type : PROCESS Swatch Groups Colorants Gray : 12 Producer : Adobe PDF library 9.90 Page Count : 14 Creator : Adobe Illustrator CS5.1EXIF Metadata provided by EXIF.tools