Powertech Co R9P016 ZigBee Tracking Energy Monitor User Manual Monitor Socket Strip CT 20120903

Powertech Industrial Co Ltd ZigBee Tracking Energy Monitor Monitor Socket Strip CT 20120903

User Manual

Download: Powertech Co R9P016 ZigBee Tracking Energy Monitor User Manual Monitor   Socket   Strip   CT 20120903
Mirror Download [FCC.gov]Powertech Co R9P016 ZigBee Tracking Energy Monitor User Manual Monitor   Socket   Strip   CT 20120903
Document ID1784561
Application IDr8xX5dt8XJBgbrVR0jZWRw==
Document DescriptionUser Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize138.01kB (1725083 bits)
Date Submitted2012-09-06 00:00:00
Date Available2012-09-06 00:00:00
Creation Date2012-09-03 16:15:24
Producing SoftwareAdobe PDF library 9.90
Document Lastmod2012-09-05 11:57:08
Document TitleMonitor & Socket & Strip & CT-20120903
Document CreatorAdobe Illustrator CS5.1

GREEN POWERLINK
ZIGBEE IN-HOME ENERGY
MONITOR SOLUTION
User Manual
© Copyright 2012
The information contained herein is subject to change without notice.
This document contains proprietary information, which is protected by copyright.
No part of this document may be photocopied, reproduced,
or translated into another language without the prior written consent.
Feb. 2012
All Versions
TABLE OF CONTENTS
INTRODUCTION ----------------------------------------------------------HARDWARE FEATURES --------------------------------------------------INSTALLATION ----------------------------------------------------------Wireless Setup Range ------------------------------------------------Install Smart Socket --------------------------------------------------Install Smart Power Strip---------------------------------------------Install CT Smart Meter in the circuit breaker panel--------------------Prepare the electrical circuit breaker----------------------------Connect the CT clamps & voltage wires
to the current & voltage input terminals----------------------------Wiring Diagram--------------------------------------------------INITIAL SETUP-----------------------------------------------------------Install Battery in Energy Monitor--------------------------------------Use an AC/DC Adapter (Included)--------------------------------------Wall Mount the Energy Monitor----------------------------------------Perform Energy Monitor Initial Setup----------------------------------Currency and Electricity Setup-----------------------------------Carbon Emission Setup--------------------------------------------OPERATION--------------------------------------------------------------Initial Smart Metering Devices and Energy Monitor pair up------------Energy Monitor Display and Control------------------------------------Change channels on the energy monitor--------------------------Turn ON/OFF the outlet of the smart socket----------------------View real time and projection energy consumption---------------View Real Time energy information for the channel--------------View projection energy information for the selected channel-----View accumulation energy consumption--------------------------Activate the energy accumulation mode for the selected channel-View total day energy accumulation for the selected channel-----View total month energy accumulation for the selected channel--View total year energy accumulation for the selected channel----Exit energy accumulation mode for the selected channel---------Reset the Energy Monitor to Factory Default------------------------------
10
12
12
12
12
13
13
14
15
15
15
16
16
17
17
18
19
19
20
21
22
23
23
Powerlink Essential Energy Monitor User Manual V1.0
INTRODUCTION
HARDWARE FEATURES
Thank you for purchasing the GREEN POWERLINK Energy Saving Solution, an
ZigBee Tracking Energy Monitor
innovative product which is designed to manage home electricity usage efficiently
ZigBee Tracking Smart Socket
R9P0160000
and reduce home electricity bill.
R9P136A600
In an effort to reduce your electricity bills, why not first check out what appliance
uses most energy in your home.
The New GREEN POWERLINK Energy Monitor allows you to take control of home
electricity usage while saving you money in the process.
With GREEN POWERLINK, you can see how much electricity you are using and
*Surge Protected Outlet
*Link up to 9 PowerLink
with greater awareness you’ll become more energy efficient.
*180J Surge Protection
energy tracking devices
Fully educated with the critical energy information, you are naturally motivated to
adopt new energy saving habits and reduce harmful carbon emission for our
environment.
The GREEN POWERLINK is the total solution for green inspiration, energy
conservation, and surge protection for your everyday life.
*ZigBee Link: 2.4GHz (IEEE 802.15.4)
*ZigBee Link: 2.4GHz (IEEE 802.15.4)
*Wireless Range: 100 ft in open area
*Transmission Time: 6 seconds
*Display instant energy consum
*Wireless Range: 100 ft in open area
*ZigBee Function: Router
ption in Watts, Cost, CO2
*Display forecasted energy usage in
*ZigBee Profile: Smart Energy 1.0
KWH, Cost, CO2 by day/month/year
*ZigBee Cluster: Simple Metering
*Display accumulated energy usage
Green LED Indicator
*Surge counter displays the
frequency of surge occurrences
*Energy Display Power Supply :
9V AC/DC adaptor (included)
Powerlink Essential Energy Monitor User Manual V1.0
*Green Surge Protected LED Indicator
*Manual ON/OFF Button w/
by day/month/year
*Security: AES 128 bits (Optional)
*Meet IEC 62053‐21 class I
standard (1~1.5%)
Powerlink Essential Energy Monitor User Manual V1.0
ZigBee Tracking Smart Strip
INSTALLATION
ZigBee Tracking Smart Meter
R9P624NI00
M9PC020000
Wireless Setup Range
The energy monitor and smart socket/strip/CT meter communicate with
wireless technology. To ensure the communication with no interruption, please
locate and setup energy monitor, smart socket/strip/CT meter within 100 Ft of
range.
*6 Surge Protected Outlets
*Transmission Time: 6 seconds
*540J Surge Protection
*ZigBee Function: Router
*Green Surge Protected LED
*ZigBee Cluster: Simple Metering
Install Smart Socket
*Installation type: 1‐phase & 3‐wire
Indicator
The single outlet smart socket allows the user to track electricity consumption
*Red Grounded Fault LED Indicator
*CT Meter Input Voltage:100~240V
*Transmission Time: 6 seconds
*CT Meter Input Current: 60A
*ZigBee Function: Router
*CT Meter Frequency: 50/60Hz
*ZigBee Cluster: Simple Metering
*CT Meter Accuracy: <1% at PF=1
1. Plug in the smart socket to a powered AC outlet.
*Manual ON/OFF Button w/
*Power Supply: Power acquired
2. Plug in the appliance into the smart socket outlet.
of individual home appliance and protect it against surge and voltage spikes.
3. The outlet power can be manually turned ON/OFF by pressing the “Manual
from electrical meter
Green LED Indicator
ON/OFF” button on the smart socket. You may also control the outlet power
*Meet IEC 62053‐21 class I
standard (1~1.5%)
remotely by using the energy monitor (see the operation instruction).
4. Perform initial energy monitor and smart socket pair up (see the operation
*ZigBee Link: 2.4GHz (IEEE 802.15.4)
instruction).
*Wireless Range: 100 ft in open area
*ZigBee Profile: Smart Energy 1.0
*Security: AES 128 bits (Optional)
Powerlink Essential Energy Monitor User Manual V1.0
Powerlink Essential Energy Monitor User Manual V1.0
PROTECTED LED LIGHT
This LED light illuminates
to indicate that the surge
protection is active and
protecting equipments
from power surges.
PROTECTED LED LIGHT
This LED light illuminates
to indicate that the surge
protection is active and
protecting equipments
from power surges.
Manual ON/OFF”
button
GROUNDED LED LIGHT
This LED light illuminates
to indicate that the surge
protector is plugged into a
properly grounded outlet.
Manual ON/OFF”
button
ALWAYS ON OUTLETS
Install Smart Power Strip
are also available for
devices which are always
kept on and need
continuous power.
The smart power strip allows the user to track electricity consumption of group
home appliances in the same area and protect it against surge and voltage spikes.
1. Plug in the smart power strip to a powered AC outlet.
2. Plug in the appliances into the smart power strip outlets.
3. The Energy Saver outlets on the power strip can be manually turned ON/OFF by
pressing the “Manual ON/OFF” button on the power strip. You may also control
the energy saver outlets remotely by using the energy monitor (see the
operation instruction).
4. Perform initial energy monitor and smart power strip pair up (see the
operation instruction).
Powerlink Essential Energy Monitor User Manual V1.0
Powerlink Essential Energy Monitor User Manual V1.0
Install CT Smart Meter in the circuit breaker panel
Connect the CT clamps & voltage wires to the current & voltage
input terminals
The CT smart meter allows the user to measure entire electricity power
Before installation, please connect the CT clamp wires to the current input
terminal following the sequence 1S(red) 1L(black) 2S(red) 2L(black). Then
connect the voltage wires to the voltage input terminal following the sequence
L(red) N(black).
consumption from electrical panel.
Caution
Your safety is very important to us. Please read these cautions regarding the
installation of your CT Smart Meter.
• Electrical panel contains live electrical wires and components even when the
main circuit breaker has been switched off. Do not attempt any installation
At the bottom of the current transformer,
unless you are familiar where these electrified areas are.
there is “K→L” indication mark.
• Any work on or near electrical panel could induce danger or fatal electrical
shock. It is highly recommended that all work should be done only by qualified
electricians or certified electrical specialist.
Before you clip on the CT over the power line, please make sure the power
current flow direction follow the “K→L” indication mark on the CT
Prepare the electrical circuit breaker
WARNING:
• Before you start, you must turn off all power in the electrical circuit breaker
by turning off the main breaker or main switch.
• Some wires and components could still be live even when the main breaker
or switch is turned off. Please indentify these wires and components before
installation and pay attention to these areas at all time.
Botton view
1. Turn off all power by turning off the main breaker or main switch.
2. Remove the cover of electricity circuit breaker panel.
Powerlink Essential Energy Monitor User Manual V1.0
Powerlink Essential Energy Monitor User Manual V1.0
Wiring Diagram
1 Phase & 3 Wire – 2CT
Refer to the following wiring diagram and dial the mode switch that matches your
electrical panel type. Then install CT clamp over the power line and voltage wires
to L and N voltage terminals.
Once the CT smart meter is installed in the electrical panel, turn on the main
breaker and perform initial energy monitor and CT smart meter pair up (see the
operation instruction).
1 Phase & 2 Wire – 1CT
Powerlink Essential Energy Monitor User Manual V1.0
10
Powerlink Essential Energy Monitor User Manual V1.0
11
INITIAL SETUP
Perform Energy Monitor Initial Setup
Perform the following initial setup steps for first time operation
1. Currency and Electricity Rate Setup
Install Battery in Energy Monitor
2. Carbon Emission Setup
Open the battery compartment on the back of the energy monitor and install 4 x
AA 1.5V alkaline batteries with right polarity.
Note: During anytime, you may press the SET button for 3 seconds to enter
Warning: Reversing the polarity may damage the product.
setup mode and change currency, electricity rate, and carbon emission rate.
Once batteries are installed, the energy monitor will turn on and enter initial setup
Currency and Electricity Setup
mode. Please proceed and refer to the next instruction for initial setup.
There are more than 4,000 electric utilities across the US and Canada. In the
Note:
event your local utility uses a tariff calculation other than flat electricity rate,
Batteries are not included in the product kit.
please key in the average rate that most nearly resembles your utility’s tariff
Please do not mix and match different types / new & old batteries in use with the
schedule.
energy monitor.
1. The $ symbol blinks first. Use the arrow key to
select currency symbol in $ /€ /£.
Use an AC/DC Adapter (Included)
2. Press the SET button to proceed to Electricity
The energy monitor can operate with the included 9V AC/DC adapter.
Utility Rate setup.
When the AC/DC adaptor is used in conjunction with batteries installed, the energy
3. The electricity rate value blinks. Use the arrow
monitor will be powered by the AC/DC adaptor to save batteries life in the energy
key to change the rate value.
monitor.
4. Press the SET button to proceed to Carbon
Wall Mount the Energy Monitor
Emission setup.
1. Select a spot within the wireless range to mount the supplied wall bracket for
Note: The default Currency is US dollar and
the energy monitor.
default Electricity rate is 0.12¢per
2. The ideal locations for the energy monitor wall mount are entrance of a room or
KWH.
location where the energy monitor can be easily seem and accessed.
3. Use adhesive tape or supplied screws to securely attach the supplied wall
bracket to a wall.
Powerlink Essential Energy Monitor User Manual V1.0
12
Powerlink Essential Energy Monitor User Manual V1.0
13
OPERATION
Carbon Emission Setup
Carbon dioxide is emitted in the process of producing electricity by burning coal &
Initial Smart Metering Devices and Energy Monitor pair up
fossil fuel. This is usually referred to CO2 footprint or carbon emission, which in
turn has contributed global warming and caused abnormal weather.
The learning function allows you to expand more smart socket/strip/CT meter
The average carbon emission rate is 0.49Kg (1.08 lbs) of carbon emission for every
later on. You may purchase more compatible smart metering devices and pair
1 KWH of electricity produced. This can be changed depending upon your local
up to 9 smart metering devices to the energy monitor.
electric utility. Please contact your local utility for carbon emission rate.
1. When pairing up smart metering devices and energy monitor, please bring
1. The Kg symbol blinks first. Use the arrow key to
energy monitor close to the smart metering devices.
select the weight symbol in Kg or LB. Then press
2. On the energy monitor, use the arrow key to select from channel 1 to 9
the SET button to proceed to carbon emission rate
which you wish to add the smart metering devices.
3. On the smart metering devices, press and hold the LEARNING button until
setup.
the LED indicator light flashes then release the button.
2. The carbon emission rate blinks. Use the arrow
4. Press the learning button on top of the energy monitor until it beeps once to
key to change the value. Press the SET button to
confirm the smart socket and energy monitor has been successfully paired
finish initial setup.
up.
5. If you hear 3 beeps buzzer from the energy monitor, this indicates the smart
Note: The default Carbon emission rate is 0.49Kg
metering devices and energy monitor has not been successfully paired up.
of carbon emission for every 1KWH of electricity
Please follow step3 to step5 to redo the pair up procedures.
produced.
6. Repeat step2 to step5 to add more smart metering devices to different
channel on the energy monitor.
Energy Monitor Display and Control
The user friendly energy monitor allows user to browse energy information
and control smart socket and strip remotely.
Discover home energy use by viewing real time, projection and accumulation
energy information in Watts, KWH, Cost, and Carbon emission. Save money by
adopting new energy saving habits and eliminating standby power waste.
Powerlink Essential Energy Monitor User Manual V1.0
14
Powerlink Essential Energy Monitor User Manual V1.0
15
Change channels on the energy monitor
View real time and projection energy consumption
The energy monitor can monitor and control
The energy monitor provides real time and
up to 9 smart metering devices. On the
projection energy information. Press the
energy monitor, each CH number
MODE button to scroll thru different energy
represents a smart metering device.
information display.
Press the arrow key to change the channel
→ Real Time
→
from CH1 to CH9 to ALL channels.
The energy monitor will not display energy
Daily Projection
→ →
information when the selected channel does
not exit.
Monthly Projection
When you select “ALL” channels, the energy
monitor will display the sum total energy
Yearly Projection
information of all available Channels.
View Real Time energy information for the channel
Turn ON/OFF the outlet of the smart socket
The energy monitor can display the ON/OFF
In Real Time Mode, the energy monitor will
Status of the energy saver outlets on the
display instant energy consumption in
surge protector.
Watts, energy cost in $/hr, and carbon
To avoid turning on or off the energy saver
emission in Kg/hr.
outlets by accident, the ON/OFF function can
only be accessed in real time mode.
In real time mode, use the ON/OFF Key on
the energy monitor to turn ON and OFF the
energy saver outlets of the surge protector.
Powerlink Essential Energy Monitor User Manual V1.0
16
Powerlink Essential Energy Monitor User Manual V1.0
17
View projection energy information for the selected channel
View accumulation energy consumption
The energy monitor provides energy usage accumulation display. This allows
DAY
MONTH
you to view total accumulation energy usage in day, month and year for each
YEAR
channel.
Activate the energy accumulation mode for the selected channel
1. Select the channel you wish to acquire
The energy monitor reads your device energy usage continuously while your device
energy usage accumulation. You can
is on and off, and calculates the projection energy information base on real time
and historical measurements.
DAY
active the energy usage accumulation for
each channel in different time.
We suggest let the energy monitor measure device several typical use cycles, and
2. In DAY mode, press the MODE button 3
the projection energy information will be more accurate.
In Projection Mode, the energy monitor will display energy consumption in KWH,
seconds to activate the energy accumula
energy cost in $, and carbon emission in Kg.
tion mode.
Use the MODE key to change from daily / monthly / yearly projection energy
information.
Powerlink Essential Energy Monitor User Manual V1.0
18
Powerlink Essential Energy Monitor User Manual V1.0
19
View total day energy accumulation for the selected channel
View total month energy accumulation for the selected channel
In daily accumulation mode, the energy monitor will display the total accumulative
In monthly accumulation mode, the energy monitor will display the total
energy information for the total duration days since accumulation mode is
accumulative energy information for the total duration months since
activated.
accumulation mode is activated.
DAY
DAY
DAY
DAY
DAY
1. The energy monitor will first display DAY01 for 3 seconds, then display the total
DAY
1. When the total energy usage accumulates over 30 days, it will move and
energy accumulation data for 10 seconds in repeat cycle.
store the total energy accumulation data in MONTH database, and the DAY
2. After 24 hours, the energy accumulation display will advance to DAY 02 and
accumulation data will be reset and re-accumulated.
display the total energy accumulation data.
2. Press the MODE button to switch and view the total energy usage
accumulation for the past duration days and months.
Note: the plug icon flashes repeatedly as an accumulation mode indicator
Powerlink Essential Energy Monitor User Manual V1.0
20
Powerlink Essential Energy Monitor User Manual V1.0
21
View total year energy accumulation for the selected channel
Exit energy accumulation mode for the selected channel
In yearly accumulation mode, the energy monitor will display the total accumula-
1. In DAY accumulation mode, press the MODE button 3 seconds to exit the
accumulation mode to projection mode.
tive energy information for the total duration years since accumulation mode is
2. The energy usage will still be accumulated and stored in device’s database.
activated.
MONTH
YEAR
Reset the Energy Monitor to Factory
Default
Please follow the instruction below to reset the energy monitor to its factory
default setting.
1. When the total energy usage accumulates over 12 months, it will move and
store the total energy accumulation data in YEAR database, and the MONTH
Note:
accumulation data will be reset and re-accumulated.
By performing resetting energy monitor to factory default, all saved data,
setup & channel settings will be erased.
2. Press the MODE button to switch and view the total energy usage accumulation
for the past duration days / months / years.
1. Locate the reset point on top of the energy monitor.
2. Push a stylus or pen into the reset point for 5 seconds.
3. The energy monitor will be hard reset to factory default setting. Please
perform all the necessary setup and channel setting.
Powerlink Essential Energy Monitor User Manual V1.0
22
Powerlink Essential Energy Monitor User Manual V1.0
23
!
CAUTION:
To assure continued FCC compliance:
Any changes or modifications not expressly approved by the grantee of this device
could void the user's authority to operate the equipment.
FEDERAL COMMUNICATIONS COMMISSION
INTERFERENCE STATEMENT
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation.
This equipment generates, uses and can radiate radio frequency energy and, if not
installed and used in accordance with the instructions, may cause harmful
interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause
harmful interference to radio or television reception, which can be determined by
turning the equipment off and on, the user is encouraged to try to correct the
interference by one or more of the following measures:
-- Reorient or relocate the receiving antenna.
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the
receiver is connected.
-- Consult the dealer or an experienced radio/TV technician for help.
CAUTION:
To assure continued FCC compliance:
Any changes or modifications not expressly approved by the grantee of this device
could void the user's authority to operate the equipment.
產品小於8*10cm就要寫在手冊
24
Powerlink Essential Energy Monitor
User Manual V1.0
內警語

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
XMP Toolkit                     : 3.1-702
Format                          : application/pdf
Title                           : Monitor & Socket & Strip & CT-20120903
Creator Tool                    : Adobe Illustrator CS5.1
Create Date                     : 2012:09:03 16:15:24+08:00
Modify Date                     : 2012:09:05 11:57:08+08:00
Metadata Date                   : 2012:09:05 11:57:08+08:00
Thumbnail Width                 : 256
Thumbnail Height                : 56
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 4463 bytes, use -b option to extract)
Document ID                     : xmp.did:EE798742172068118083E395AA583615
Instance ID                     : uuid:c0301704-4964-43c9-905c-d41eab9c3ceb
Original Document ID            : uuid:801EF41CDEAF11DF924CD171F6479B81
Rendition Class                 : proof:pdf
Derived From Instance ID        : uuid:f69df8d8-cf42-d547-87ed-72c88d109d2c
Derived From Document ID        : xmp.did:414966981D2068118083CCE25350421E
Derived From Original Document ID: uuid:801EF41CDEAF11DF924CD171F6479B81
Derived From Rendition Class    : proof:pdf
History Action                  : saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:94A08A962F2068118083B73BE0020E3F, xmp.iid:F97F1174072068118C14C16D92274346, xmp.iid:08801174072068118083CCE25350421E, xmp.iid:414966981D2068118083CCE25350421E, xmp.iid:EE798742172068118083E395AA583615
History When                    : 2011:12:29 15:19:42+08:00, 2012:02:14 17:21:36+08:00, 2012:02:22 14:55:09+08:00, 2012:02:22 17:49:51+08:00, 2012:09:03 16:15:11+08:00
History Software Agent          : Adobe Illustrator CS5.1, Adobe Illustrator CS5.1, Adobe Illustrator CS5.1, Adobe Illustrator CS5.1, Adobe Illustrator CS5.1
History Changed                 : /, /, /, /, /
Manifest Link Form              : EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference, EmbedByReference
Manifest Reference File Path    : /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee CT-2.psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee-6.psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/DSC_0121-strip..psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee-3.psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee-1.psd, /Users/olivea/Desktop/imac/型錄/日規/link image/green power zigbee/zigbee-3.psd, /Users/olivea/Desktop/imac/ 中性包材設計/ 說明書/Zigbee_Monitor & Socket & Strip & CT 20120903/link/zigbee-3.psd
Startup Profile                 : Basic CMYK
N Pages                         : 1
Has Visible Transparency        : True
Has Visible Overprint           : False
Max Page Size W                 : 209.999929
Max Page Size H                 : 148.500152
Max Page Size Unit              : Millimeters
Font Name                       : ArialMT, Arial-BoldMT, MyriadPro-Regular, DIN-Regular, DIN-Medium, DIN-Bold, DIN-Black, DINOT-Bold, LiHeiPro, AdobeMingStd-Light, DFHei-Md
Font Family                     : Arial, Arial, Myriad Pro, DIN, DIN, DIN, DIN, DINOT, 儷黑 Pro, Adobe 明體 Std, DFHei Md-HK-BF
Font Face                       : Regular, Bold, Regular, Regular, Medium, Bold, Black, Bold, 中黑, L, Md-HK-BF
Font Type                       : Open Type, Open Type, Open Type, Type 1, Type 1, Type 1, Type 1, Open Type, TrueType, Open Type, Unknown
Font Version                    : Version 5.06, Version 5.06, Version 2.102;PS 2.000;hotconv 1.0.67;makeotf.lib2.5.33168, 001.000, 003.130, 001.000, 001.000, Version 7.460;PS 7.046;hotconv 1.0.38, 6.0d4e1, Version 6.007;PS 6.001;hotconv 1.0.67;makeotf.lib2.5.33168, 7.0d17e1
Font Composite                  : False, False, False, False, False, False, False, False, False, False, False
Font File Name                  : Arial.ttf, Arial Bold.ttf, MyriadPro-Regular.otf, DINReg; DIN-Regular, DINMed; DIN-Medium, DINBol; DIN-Bold, DINBla; DIN-Black, DINOT-Bold.otf, 儷黑 Pro.ttf, AdobeMingStd-Light.otf, STHeiti Light.ttc
Plate Names                     : Cyan, Magenta, Yellow, Black, PANTONE Black C
Swatch Groups Colorants Red     : 59
Swatch Groups Colorants Green   : 35
Swatch Groups Colorants Blue    : 20
Swatch Groups Colorants Tint    : 100.000000
Swatch Groups Colorants Cyan    : 0.000000
Swatch Groups Colorants Magenta : 13.000000
Swatch Groups Colorants Yellow  : 48.999996
Swatch Groups Colorants Black   : 97.999992
Swatch Groups Group Name        : Grayscale
Swatch Groups Group Type        : 1
Swatch Groups Colorants Swatch Name: K=5
Swatch Groups Colorants Mode    : GRAY
Swatch Groups Colorants Type    : PROCESS
Swatch Groups Colorants Gray    : 12
Producer                        : Adobe PDF library 9.90
Page Count                      : 14
Creator                         : Adobe Illustrator CS5.1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: NHS-R9P016

Navigation menu