Powerware® 5140 Rack-Mount UPS Product Snapshot Rating: 6000 VA/ 6000 Watts Voltage: 200-240 Vac Frequency: 50/60 Hz Configuration: 6U rack-mount for standard 19-inch racks T o meet the power protection needs of In addition to its exceptional power rating and size, the Powerware 5140 also F e a ture s applications, Powerware Corporation incorporates Advanced Battery A (formerly Exide Electronics) proudly intro- Management (ABM™) which assures Power Factor Corrected (PFC) design protects more equipment duces the Powerware 5140 Rack-Mount reliability and improves performance by A uninterruptible power system (UPS). The doubling battery service life, optimizing 6U rack height conserves valuable rack space Powerware 5140 is powerful and flexible recharge time, and providing up to a 60- A enough to respond to the demands of day notice of the end of useful battery life. Advanced Battery Management (ABM™) doubles battery service life A Buck and Boost voltage regulation with pure sine wave output A Extended Battery Modules (EBMs) prolong run times A Modular design eases setup and service A Load Segments (separate receptacle groups) enable scheduled shutdowns and maximize run time for critical devices A Hot-Swappable batteries and Manual Bypass Switch simplify service A Backed by 10-Year Pro-rated Warranty (U.S. and Canada) rapidly expanding rack-based virtually any Enterprise computing network. The Powerware 5140 utilizes multiple receptacle groups, called Load Segments, The Powerware 5140 is designed with a which can be pre-configured to shutdown unity power factor rating, meaning it is peripherals first to effectively triple battery ideally suited to meet the requirements of run times for the most critical equipment. today's Power Factor Corrected (PFC) Extended Battery Modules (EBMs) are also loads. With proven and reliable technology, available to extend run times, and to it delivers up to a third more power than preserve data integrity, the Powerware traditionally rated UPSs while still 5140 is bundled with award-winning occupying only 6U (10.5 inches) of LanSafe III and FailSafe III power valuable rack space. management software. Technical Specifications1 Advanced Battery Management (ABM™) Technology Doubles Battery Service Life The lead-acid batteries typically used in a UPS are considered viable as long as they can maintain backup times of at least half that of new batteries. The illustration to the right shows that batteries that are constantly trickle charged (as are virtually all other UPS batteries on the market today) reach the end of their useful life in less than half the time of batteries charged using ABM. ABM uses a patented three-stage charging technique that not only doubles battery service life, but Data based upon tests performed by an independent battery manufacturer. also optimizes battery recharge time and provides up to a 60-day advanced notification of pending end of useful battery life. ELECTRICAL INPUT C O M M U N I C AT I O N S Voltage 200, 208, 220, 230, & 240 Vac user-selectable; see Model Selection Guide for default settings Serial Ports Normal Voltage Range ±20% of nominal voltage without using batteries Extended Voltage Range 160-288V without using batteries (set via front panel) Frequency 50/60 Hz, ±3 Hz (+5/-3 Hz with extended voltage range) Connection Hardwired Efficiency 96% ELECTRICAL OUTPUT User LEDs LCD LCD Languages Front Panel Buttons Communications Cable (2) Serial communication ports for use with power management software and installable option cards, including ConnectUPS SLC-EM SNMP Adapter and the Port Expander Card Normal Operation (green), On Battery (yellow), On Bypass (yellow), and Alarm (red) Two-line LCD with three button control Danish, Dutch, English, French, German, Spanish, Italian, and Japanese On, Off, and Alarm Silence/Self Test 6-foot communication cable included Power Out 6000 VA/6000 Watts E N V I R O N M E N TA L A N D S A F E T Y Voltage Range (online) ±10% of nominal voltage Operating Temperature Voltage Range (on battery) ±5% of nominal voltage Transit Temperature -20°C to 55°C Wave Form (on battery) Sine Wave Frequency Same as input (±0.5% during battery operation) Connections Receptacles or hardwired; see Model Selection Guide Max Current 29A at 208 Vac; 26A at 230 Vac Output Protection Resettable circuit breakers B AT T E R Y 10°C to 40°C (25°C for optimal performance) Storage Temperature 0°C to 25°C Humidity (Operation) 20 to 80% (noncondensing) Humidity (Non-operating) 5 to 95% Operating Altitude 0 to 10,000 feet (non-operating: 0 to 30,000 feet) Audible Noise 55 dBA at 1 meter Safety Markings UL, CSA, NOM. Models PW5140 6000i and PW5140 6000 HW also CE and VDE Safety Certifications UL1778; CSA22.2 No.107.1,No.107.2,No.950; CB Bulletin No.86AI; EN50091-1; EN60950; EMKO-TSE207/95; NOM-019-SCFI-1993 Type Maintenance-free, sealed, valve-regulated lead-acid (VRLA), (28), 12V 5 AH Extended Batteries Maximum of 2 Extended Battery Modules (EBMs) Backup Time See Battery Run Times table EMC Markings FCC-A; CISPR-A; VCCI Recharge Time <3 hours to 80% usable capacity Immunity IEC 801-2, IEC 801-3, IEC 801-4, IEC 801-5 Extended Battery Recharge Time <10 hours to 80% usable capacity Surge Suppression Conforms to IEEE 587B and ANSI C62.41 REPO Port Meets NEC code 645-11 intent and UL requirements 1. Due to continuing product improvement programs, specifications are subject to change without notice. Powerware 5140 Features Load Segments Load Segments are groups of receptacles that can be independently controlled via the front panel LCD interface and/or LanSafe III/FailSafe III, which is bundled with the Powerware 5140. Load Segments provide extended battery run times and flexible management of the UPS. The five Load Segments of model PW5140 6000i are outlined below. Unity Power Factor Rating What does unity power factor rating mean? Quite simply, it means that the watt rating of the UPS is equal to its VA rating. Traditionally, UPSs have been designed, built, and sold with a Load Segments divide the Powerware 5140 into five virtual UPSs power factor rating of approximately 0.6 to 0.7. For example, a 1000 VA UPS could supply a Shut down Load Segments to decrease load and extend backup time for other Load Segments Reboot a locked up server by turning a Load Segment off and on maximum of 600 to 700 watts. Historically, this 0.7 power factor was appropriate for the majority of computer loads the UPS was intended to support since most computers demanded power at a 0.7 power factor. Today, however, a large percentage of high-end computers, utilize Power Factor Corrected (PFC) power supplies, which have a power Front Panel Display factor of approximately 1.0. Take a look at the configuration below: Equipment Load: Watts Load: VA (3) Servers* 3300 3366 (2) Workstations* 1000 1020 (1) Color Monitor 200 300 Total 4500 4686 LCD Status Screen Menu Navigation Keys Bypass LED UPS On Battery Alarm LED Power On (Normal) *Equipment with PFC power supplies. On Off Alarm Silence/ Self-Test To support this load, you need to select a UPS with a rating that meets or exceeds both Extended Battery Modules (EBMs) the watt and VA demand shown above. To extend battery backup times, you can connect up to two EBMs. Each EBM occupies A traditionally rated 5000 VA/3750 watt UPS 3U (5.25 inches) of rack space. without a unity power factor rating cannot be used. The Powerware 5140, on the other You can hot-swap both the standard batteries and EBMs without powering down the connected load. This makes it possible to extend the life of the UPS without returning the unit for service. hand, has capacity to spare. Powerware® 5140 Model Selection Guide MODEL NUMBER POWER OUT (VA/W AT T ) I N P U T /O U T P U T V O LTA G E (V A C ) FREQUENCY (H Z ) INPUT CONNECTION PW5140 6000i 6000/6000 208/2302 50/603 Hardwired PW5140 6000 6000/6000 208/2302 50/603 Hardwired PW5140 6000 HW Options 6000/6000 208/2302 50/603 Hardwired PW5140 BATT – – – PW5140 PDU7 250/250 120 PW5119 MK23 – – OUTPUT R E C E P TA C L E S (12) IEC-320, C13 & (3) IEC-320, C194 (2) L6-30R & (2) IEC-3205 Hardwired & (2) IEC-3205 60 Custom Adapter Custom Adapter (2) 5-15R – – – – DIMENSIONS (H X W X D) 1 10.5 x 17.25 x 24.3 in 26.7 x 43.8 x 61.7 cm 10.5 x 17.25 x 24.3 in 26.7 x 43.8 x 61.7 cm 10.5 x 17.25 x 24.3 in 26.7 x 43.8 x 61.7 cm 5.25 x 17.25 x 22.5 in 13.3 x 43.8 x 57.2 cm 1.98 x 19.28 x 9.90 in 5.03 x 48.97 x 25.15 cm Adjustable; fits standard 19-inch rack WEIGHT (KG/LB) 136/3006 136/3006 136/3006 81.6/180 8.6/19 4.5/10 1. 19-inch wide front panel with a 17.25-inch wide chassis; depth does not include front panel (.5 inches) 2. 208/230 Vac auto-sensing default. User-selectable via LCD interface for 200, 208, 220, 230, and 240 Vac. 3. Automatic frequency synchronization. 4. Divided into 5 Load Segments. 5. Divided into 2 Load Segments; IEC-320 receptacles are used to connect optional PW5140 PDU. 6. Shipping weight is 325 pounds (147 kg). 7. Sidewall design occupies 0U of rack space. B AT T E R Y R U N T I M E S LOAD 1000 Watts 2000 Watts 3000 Watts 4000 Watts 5000 Watts 6000 Watts S TA N D A R D ONE ADDITIONAL TWO ADDITIONAL B AT T E R I E S 1 hour 2 minutes 28 minutes 18 minutes 12 minutes 8 minutes 6 minutes E X T E N D E D B AT T E R Y M O D U L E 2 hours 24 minutes 1 hour 6 minutes 40 minutes 28 minutes 21 minutes 18 minutes E X T E N D E D B AT T E R Y M O D U L E S 3 hours 56 minutes 1 hour 47 minutes 1 hour 6 minutes 47 minutes 36 minutes 28 minutes This table provides typical information. Battery times are approximate and may vary with equipment, configuration, disk access, battery use, temperature, etc. R E A R PA N E L S PW5140 6000i PW5140 6000 HW PW5140 6000 A (2) I N S TA L L A B L E O P T I O N S L O T S E HARDWIRE INPUT I B (2) C O M M U N I C AT I O N P O R T S F LOAD SEGMENT 1 J LOAD SEGMENT 5 LOAD SEGMENT 4 C M A N U A L B Y PA S S S W I T C H G LOAD SEGMENT 2 K CIRCUIT BREAKER(S) D REPO P O R T H LOAD SEGMENT 3 L IEC-320 R E C E P TA C L E S M HARDWIRE OUTPUT Powerware Corporation Corporate Headquarters Latin America/Caribbean China and North Asia 8609 Six Forks Road Raleigh, NC 27615 U.S.A. Toll Free: 1.877.797.9273 (PWRWARE) or 919.872.3020 Fax: 1.800.753.9433 or 919.870.3411 E-mail: info@powerware.com www.powerware.com Europe/Middle East/Africa Australia and South Pacific Southeast Asia Canada Revision 5140FXA 7/99 Reprint 7/99 Sunrise, FL: 954.835.1180 Berkshire, England: 44.1753.606700 Singapore: 65.861.9877 Hong Kong: 852.2745.6682 Sydney, Australia: 61.2.9878.5000 Toronto, Ontario: 416.798.0112 FOR PDU C O N N E C T I O N
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.1 Linearized : No Page Count : 4 Create Date : 1999:07:26 14:14:34 Producer : Acrobat Distiller 3.01 for Power Macintosh Creator : QuarkXPressª 4.03: LaserWriter 8 8.5.1 Author : mdeeb Title : _PW5140_.799EXIF Metadata provided by EXIF.tools