Powerwave Technologies 5JS0045 Multicarrier PCS Power Amplifier User Manual Section 4

Powerwave Technologies Inc Multicarrier PCS Power Amplifier Section 4

User Manual Section 4

Download: Powerwave Technologies 5JS0045 Multicarrier PCS Power Amplifier User Manual Section 4
Mirror Download [FCC.gov]Powerwave Technologies 5JS0045 Multicarrier PCS Power Amplifier User Manual Section 4
Document ID122741
Application IDxGk+8GSWzf4bf4xgMbtp1w==
Document DescriptionUser Manual Section 4
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatMicrosoft Word - pdf
Filesize7.37kB (92161 bits)
Date Submitted2000-10-26 00:00:00
Date Available2001-01-17 00:00:00
Creation Date2000-10-26 03:46:42
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2000-10-26 03:46:44
Document TitleUser Manual Section 4

Section
PRINCIPLES OF OPERATION
4-1. INTRODUCTION
This section contains a functional description of the multicarrier cellular amplifier.
4-2. RF INPUT SIGNAL
The maximum input power for all carrier frequencies should not exceed the limits specified in table
1-2. For proper amplifier loop balance, the out of band components of the input signals should not
exceed -40 dBc. The input VSWR should be 2:1 maximum (or better).
4-3. RF OUTPUT LOAD
The load impedance should be as good as possible (1.5:1 or better) in the working band for good
power transfer to the load. If the amplifier is operated into a filter, it will maintain its distortion
characteristics outside the signal band even if the VSWR is infinite, provided the reflected power
does not exceed one watt. A parasitic signal of less than one watt incident on the output will not
cause distortion at a higher level than the normal forward distortion (i.e. -65 dBc).
4-4. SYSTEM FUNCTIONAL DESCRIPTION
The G3S-1900-80 amplifier is a linear, feed-forward power amplifier that operates in the 60 MHz
frequency band from 1930 MHz to 1990 MHz. It is designed to operate in a maximum of two
continuous frequency blocks in the PCS band or an instantaneous bandwidth of 20 MHz. A typical
two-module system is shown in figure 4-1. The power output specification is listed in table 1-2.
Each amplifier is a self-contained plug-in module and is functionally independent of the other
amplifier module. The amplifier modules are designed for parallel operation to achieve high peak
power output, and for redundancy in unmanned remote locations. Each amplifier in the system can
simultaneously transmit multiple carrier frequencies, at an average total power output of 70 watts
(one amplifier module in a subrack unit) to 140 watts (two amplifier modules), with -65 dBc third
order intermodulation distortion (IMD).
The output from each amplifier is an amplified composite signal of approximately 80 watts before
combiner losses. All phase and gain corrections are performed on the signal(s) in the individual
amplifier modules. In a two-module system, the amplifier outputs are fed to a power combiner and
combined to form a composite RF output of up to 140 watts. Each amplifier module has an alarm
and display board that monitors the amplifier performance. If a failure or fault occurs in an
amplifier module, it is displayed on the individual amplifier front panel.
4-5. G3S-1900-80 AMPLIFIER MODULE
The amplifier module, figure 4-2, has an average output of 80 watts power (800 watts peak
power) with intermodulation products suppressed to better than -65 dBc below carrier levels. The
amplifier provides an amplified output signal with constant gain and phase by adding approximately
25 dB of distortion cancellation on the output signal. Constant gain and phase is maintained by
continuously comparing active paths with passive references, and correcting for small variations
through the RF feedback controls. All gain and phase variations, for example those due to
temperature, are reduced to the passive reference variations. The amplifier module is comprised
of:
044-05077 Rev. A
4-1
Preamplifiers
Main amplifier
Error amplifier
Two feed-forward loops with phase-shift and gain controls
DC/DC power regulator
Alarm monitoring, control, and display panel
VVA
ACTIVE POWER COMBINER
RF IN J9
POWER SPLITTER
SPLITTER &
SIGNAL DIST.
ASSY.
500-01435
MCA 1
17
MCA 2
17
100
COUPLER
BPF
RF OUT J2
SIGNAL DISTRIBUTION
500-01467
COMBINER
ASSY
500-01434
12
30
IN-RUSH
RMS DET.
500-01451
IN-RUSH
J3/J4
DC_CH1
80A MAX
J5/J6
DC_CH2
80A MAX
ALC_LED
CONTROL
ASSEMBLY
500-01105
INTERFACE
ASSY.
500-01468
2X3
MOD PORT
2X3
BDM PORT
DB9
FORM C ALARMS J1
DB9
RS485/ADD.
J7
DB9
RS485/RS232
J8
Figure 4-1. G3S-1900-80 Two-Module Amplifier System
The main amplifier employs class AB amplification for maximum efficiency. The error amplifier and
feed forward loops are employed to correct signal nonlinearities introduced by the class AB main
amplifier. The error amplifier operates in class AB mode. The RF input signals are amplified by a
preamp and coupled to an attenuator and phase shifter in the first feed-forward loop. The main
signal is phase shifted by 180 degrees and amplified in the premain amplifier. The output from the
premain amplifier is fed to the class AB main amplifier. The output from the main amplifier is
typically 100 watts. The signal is output to several couplers and a delay line.
The signal output from the main amplifier is sampled using a coupler, and the sample signal is
combined with the main input signal and input to the second feed-forward loop. The error signal is
attenuated, phase shifted 180 degrees, then fed to the error amplifier where it is amplified to a
level identical to the sampled output from the main amplifier. The output from the error amplifier is
then coupled back and added to the output from the main amplifier. The control loops continuously
make adjustments to cancel out any distortion in the final output signals.
044-05077 Rev. A
4-2
The primary function of the first loop is to provide an error signal for the second loop. The primary
function of the second loop is to amplify the error signal to cancel out spurious products developed
in the main amplifier. The input signal is amplified by a preamplifier and fed to a coupler and delay
line. The signal from the coupler is fed to the attenuator and phase shifter in the 1st loop. The
first loop control section phase shifts the main input signals by 180 degrees and constantly
monitors the output for correct phase and gain.
Figure 4-2. G3S-1900-80 Power Amplifier Module Functional Block Diagram
The 2nd loop control section obtains a sample of the distortion added to the output signals by the
main amplifiers, phase shifts the signals by 180 degrees, then feeds it to the error amplifier.
There it is amplified to the same power level as the input sample and coupled on to the main
output signal. The final output is monitored by the 2nd loop and adjusted to ensure that the signal
distortion and IMD on the final output is canceled out.
4-5.1. MAIN AMPLIFIER
The input and output of the amplifier employ two-stage, class AB amplifiers, which provide
approximately 25 dB of gain in the 60 MHz frequency band from 1930 to 1990 MHz. The amplifier
operates on +27 Vdc, and is mounted directly on a heat sink, which is temperature monitored by a
thermal sensor. If the heat sink temperature exceeds 85 °C, a high temperature fault occurs. The
alarm logic controls the transistor bias voltage, which shuts down the amplifier.
4-5.2. ERROR AMPLIFIER
The main function of the error amplifier is to sample and amplify the signal distortion level
generated by the main amplifier, to a level that cancels out the distortion and IMD when the error
signal is coupled onto the main signal at the amplifier output. The error amplifier is a balanced
multistage, class AB amplifier, has 75 dB of gain, and produces up to a 65-watt output. The
amplifier operates on +27 Vdc and is mounted directly on a heat sink.
4-5.3. AMPLIFIER MONITORING
In the main and error amplifier modules, all normal variations are automatically compensated for by
the feedforward loop control. However, when large variations occur beyond the adjustment
044-05077 Rev. A
4-3
range of the loop control, a loop fault will occur. The alarms are displayed on the front panel
indicators and output via a 21-pin connector on the rear of the module to the subrack summary
board for subsequent remote monitoring via the ALARMS connector. Refer to paragraph 2-5.1 as
well as figure 2-2 and table 2-1 for a description of the ALARMS connector.
4-5.4. AMPLIFIER MODULE COOLING
Although each amplifier module contains its own heat sink, it is cooled with forced air. Four fans
are used for forced air cooling and redundancy. The fans, located on the front and rear of the
amplifier module, draw air in through the front of the amplifier and exhaust hot air out the back of
the module. The fans are field replaceable.
4-6. POWER DISTRIBUTION
Primary DC power for the system is provided by the host system to the MCR2200 Series subrack.
The subrack supplies each amplifier module with +27 Vdc directly and via the RF power
splitter/combiner. The amplifier module has a DC/DC converter that converts the +27 Vdc to +15
Vdc, +5 Vdc and -5 Vdc.
4-7. INTERMODULATION
The G3S-1900-80 amplifier is designed to deliver a 80-watt composite average power, multicarrier
signal, occupying a bandwidth less than or equal to 20 MHz, in the bandwidth from 1930 to 1990
MHz. The maximum average power for linear operation, and thus the amplifier efficiency, will
depend on the type of signal amplified.
4-7.1 TWO TONE INTERMODULATION
When measured with two equal CW tones spaced anywhere from 30 kHz to 20 MHz apart, and at
any power level up to the average power, the third order intermodulation products will be below
-65 dBc
4-7.2 MULTITONE INTERMODULATION
Adding more tones to the signal will lower individual intermodulation products. If the frequencies
are not equally spaced, the level of intermodulation products gets very low. When the frequencies
are equally spaced, those products fall on top of each other on the same frequency grid. The
average power of all intermodulation beats falling on the same frequency is called the composite
intermodulation; it is -65 dBc or better.
4-8. ALARMS
The presence of several plug-in amplifier alarms can be detected at the DC and logic connector on
the amplifier rear panel. Refer to table 2-1 and figure 2-2 for a description of the connector.
044-05077 Rev. A
4-4

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2000:10:26 03:46:42
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2000:10:26 03:46:44-04:00
Page Count                      : 4
EXIF Metadata provided by EXIF.tools
FCC ID Filing: E675JS0045

Navigation menu