Powerwave Technologies 5JS0045 Multicarrier PCS Power Amplifier User Manual Section 6

Powerwave Technologies Inc Multicarrier PCS Power Amplifier Section 6

User Manual Section 6

Download: Powerwave Technologies 5JS0045 Multicarrier PCS Power Amplifier User Manual Section 6
Mirror Download [FCC.gov]Powerwave Technologies 5JS0045 Multicarrier PCS Power Amplifier User Manual Section 6
Document ID122742
Application IDxGk+8GSWzf4bf4xgMbtp1w==
Document DescriptionUser Manual Section 6
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatMicrosoft Word - pdf
Filesize2.25kB (28161 bits)
Date Submitted2000-10-26 00:00:00
Date Available2001-01-17 00:00:00
Creation Date2000-10-26 03:47:21
Producing SoftwareAcrobat Distiller 4.0 for Windows
Document Lastmod2000-10-26 03:47:22
Document TitleUser Manual Section 6

Section
TROUBLESHOOTING
6-1
INTRODUCTION
This section contains a list of problems which users have encountered and a few suggested
actions that may correct the problem. If the suggested corrective action does not eliminate the
problem, please contact your Powerwave field representative or the factory for further instructions.
NOTE
Check your sales order and equipment warranty
before attempting to service or repair the unit. Do
not break the seals on equipment under warranty or
the warranty will be null and void. Do not return
equipment for warranty or repair service until proper
shipping instructions are received from the factory.
6-2
TROUBLESHOOTING
Refer to table 6-1 for troubleshooting suggestions.
SYMPTOM
Any voltage indicators (green)
are not lit or blinking
HIGH TEMP alarm (red) is lit
OVER PWR alarm (red) is lit
VSWR alarm (red) is lit
LOW PWR alarm (red) is lit
Table 6-1. Troubleshooting.
SUGGESTED ACTION
1. Check that subrack power connection is secure.
2. Check for proper power supply voltage.
3. Check fuses or circuit breakers on amplifier or subrack.
4. Verify that amplifier is fully inserted into subrack.
1. Verify fan(s) are operating properly.
2. Check ambient temperature (not to exceed spec – see
table 1-2).
Verify RF input level does not exceed spec – see table 1-2.
Check output connections and cables for integrity and
tightness.
Contact Powerwave field representative or factory.
6-3
RETURN FOR SERVICE PROCEDURES
When returning products to Powerwave, the following procedures will ensure optimum response.
6-3.1
Obtaining an RMA
A Return Material Authorization (RMA) number must be obtained prior to returning
equipment to the factory for service. Please contact our Repair Department at
(949) 809-1100 to obtain this number, or FAX your request to (949) 757-6676. Failure to
obtain this RMA number may result in delays in receiving repair service.
6-3.2
Repackaging for Shipment
To ensure safe shipment of the amplifier, it is recommended that the package designed
for the amplifier be used. The original packaging material is reusable. If it is not available,
contact our Repair Department for packing materials and information.
044-05077 Rev. A
6-1

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.2
Linearized                      : Yes
Create Date                     : 2000:10:26 03:47:21
Producer                        : Acrobat Distiller 4.0 for Windows
Modify Date                     : 2000:10:26 03:47:22-04:00
Page Count                      : 1
EXIF Metadata provided by EXIF.tools
FCC ID Filing: E675JS0045

Navigation menu