Powerwave Technologies 5JS0058 Multi-Carrier Power Amplifier User Manual I GENERAL DESCRIPTION
Powerwave Technologies Inc Multi-Carrier Power Amplifier I GENERAL DESCRIPTION
User Manual
869-894 MHz G3S-800-180-29 Installation & Service Manual Multi-Carrier Power Amplifier 869 – 894 MHz 180 Watts Average Power (210 W Max.) -60 dBc Intermodulation Distortion Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A April 2002 G3S-800-180-029 Installation & Service Manual © 2002 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies, and the Powerwave logo are registered trademarks Powerwave Technologies, Inc. reserves the right to make changes to the documentation and equipment, including but not limited to component substitution and circuitry changes. Changes that impact this manual may subsequently be incorporated in a later revision of this manual. April 2002 Powerwave Technologies, Inc. 1801 East St. Andrew Place Santa Ana, CA 92705 Tel: (714) 466-1000 (888) 797-9283 Fax: (714) 466-5800 Web Site: www.powerwave.com Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A ii April 2002 G3S-800-180-029 Installation & Service Manual Table Of Contents Section 1 General Description Par. No. 1-1 1-2 1-3 1-4 1-5 Page No. Introduction.......................................................................................................................................................... 1-1 General Description.......................................................................................................................................... 1-1 Functional And Physical Specifications ....................................................................................................... 1-1 Equipment Changes............................................................................................................................................ 1-1 Ordering Information.......................................................................................................................................... 1-2 Section 2 Installation 2-1 2-2 2-3 2-4 2-5 2-6 2-6.1 2-6.2 Introduction.......................................................................................................................................................... 2-1 Electrical Service Recommendations............................................................................................................ 2-1 Air Conditioning .................................................................................................................................................. 2-2 Unpacking and Inspection................................................................................................................................ 2-2 Installation Instructions .................................................................................................................................... 2-3 Amplifier Module Connectors.......................................................................................................................... 2-4 Amplifier Module Status, Alarm, Control, and Power Connector ............................................................ 2-4 Amplifier Module RF Connector ...................................................................................................................... 2-5 Section 3 Operating Instructions 3-1 3-2 3-2.1 3-2.1.1 3-2.1.2 3-2.1.3 3-2.1.4 3-2.1.5 3-2.1.6 3-2.2 3-3 Introduction.......................................................................................................................................................... 3-1 Location and Function of Amplifier Module Controls and Indicators ..................................................... 3-1 Voltage Indicators and On/Off /Reset Switch............................................................................................... 3-1 On Off Switch....................................................................................................................................................... 3-1 RF On Switch ....................................................................................................................................................... 3-1 +27VDC Indicator ................................................................................................................................................ 3-2 +15VDC Indicator ................................................................................................................................................ 3-2 +5VDC Indicator .................................................................................................................................................. 3-2 -5VDC Indicator ................................................................................................................................................... 3-2 Alarm Indicators ................................................................................................................................................. 3-2 Initial Start-Up and Operating Procedures ................................................................................................... 3-4 Section 4 Principles of Operation 4-1 4-2 4-3 4-4 4-4.1 4-4.2 4-4.3 4-4.4 4-5 4-6 4-7 Introduction.......................................................................................................................................................... 4-1 RF Input Signal .................................................................................................................................................... 4-1 RF Output Load..................................................................................................................................................... 4-1 G3S-800-180-029 Amplifier Module ................................................................................................................ 4-1 Main Amplifier .................................................................................................................................................... 4-2 Error Amplifier..................................................................................................................................................... 4-2 Amplifier Monitoring ......................................................................................................................................... 4-2 Amplifier Module Cooling ................................................................................................................................ 4-3 Power Distribution ............................................................................................................................................. 4-3 Intermodulation................................................................................................................................................... 4-3 Alarms................................................................................................................................................................... 4-3 Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A iii April 2002 G3S-800-180-029 Installation & Service Manual Section 5 Maintenance 5-1 5-2 5-3 5-4 5-5 5-5.1 5-5.1.1 5-5.1.2 5-5.1.3 5-5.1.4 5-5.1.5 5-6 5-6.1 5-6.2 Introduction.......................................................................................................................................................... 5-1 Periodic Maintenance....................................................................................................................................... 5-1 Test Equipment Required For Test .................................................................................................................. 5-1 Clean Air Inlets/Outlets..................................................................................................................................... 5-2 Performance Test ............................................................................................................................................... 5-2 Amplifier System Performance Test............................................................................................................... 5-2 Amplifier IMD Test ..............................................................................................................................................5.3 Gain Test............................................................................................................................................................... 5-3 Harmonic Test ..................................................................................................................................................... 5-3 Spurious Emissions Test................................................................................................................................... 5-4 Input Return Loss ................................................................................................................................................ 5-4 Field Replacement Parts and Modules.......................................................................................................... 5-5 G3S-800-180-029 Power Amplifier Module................................................................................................... 5-5 Cooling Fans ........................................................................................................................................................ 5-6 Section 6 Troubleshooting 6-1 6-2 6-2.1 6-2.2 6-2.3 6-2.4 6-2.5 6-2.6 6-2.7 6-2.8 6-2.9 6-3 6-3.1 6-3.2 Introduction.......................................................................................................................................................... 6-1 Troubleshooting .................................................................................................................................................. 6-1 DC Voltage Indicators Not Illuminated .......................................................................................................... 6-1 OVER PWR Illuminated or Blinking ................................................................................................................ 6-1 HIGH TEMP Illuminated .................................................................................................................................... 6-2 VSWR Illuminated .............................................................................................................................................. 6-2 DC FAIL Illuminated............................................................................................................................................ 6-3 FAN FAIL Illuminated ......................................................................................................................................... 6-3 LOOP FAIL Illuminated....................................................................................................................................... 6-3 LOW PWR Illuminated....................................................................................................................................... 6-3 LPA DISABLE Illumunated ................................................................................................................................ 6-3 Return for Service Procedures ........................................................................................................................ 6-4 Obtaining an RMA .............................................................................................................................................. 6-4 Repackaging for Shipment ............................................................................................................................... 6-4 List of Illustrations Figure No. 1-1 2-1 2-2 2-3 3-1 4-1 5-1 5-2 G3S-800-180-029 Front and Side View ........................................................................................................... 1-3 G3S-800-180-029 Rear View ............................................................................................................................. 2-4 DC and Logic Connector.................................................................................................................................... 2-4 Amplifier RF Connector ..................................................................................................................................... 2-5 G3S-800-180-029 Amplifier Module RF Control Indicators ........................................................................ 3-1 G3S-800-180-029 Power Amplifier Module Functional Block Diagram ................................................. 4-2 Amplifier System Test Setup Diagram........................................................................................................... 5-3 Amplifier Spring Clip Location ........................................................................................................................ 5-5 Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A iv April 2002 G3S-800-180-029 Installation & Service Manual List Of Tables Table No. 1-1 1-2 2-1 2-2 2-3 2-4 2-5 3-2 5-1 5-2 5-3 Major Amplifier Components........................................................................................................................... 1-2 G3S-800-180-029 MCPA Functional Specifications .................................................................................... 1-2 Sample of DC Cable Ratings............................................................................................................................. 2-1 Averaged DC Current Load ............................................................................................................................... 2-2 Averaged Heat Loading ..................................................................................................................................... 2-3 Amplifier Module DC and Logic Connector Definition............................................................................... 2-5 Amplifier RF Connector Definition.................................................................................................................. 2-4 Amplifier Module Alarm Indicators Definition ............................................................................................ 3-3 Periodic Maintenance....................................................................................................................................... 5-1 Test Equipment Required .................................................................................................................................. 5-2 MCPA Test Data Sheet ...................................................................................................................................... 5-5 Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A April 2002 G3S-800-180-029 Installation & Service Manual Section 1 General Description 1-1 Introduction This manual contains information and procedures for installation, operation, and maintenance of Powerwave’s G3S-800-180-029 multicarrier cellular amplifier. The manual is organized into six sections as follows: Section 1. General Description Section 2. Installation Section 3. Operating Instructions Section 4. Principles of Operation Section 5. Maintenance Section 6. Troubleshooting 1-2 General Description The G3S-800-180-029 (see figure 1-1) is a linear, feed-forward power amplifier that operates in the 25 MHz frequency band from 869 MHz to 894 MHz. The amplifier can simultaneously transmit multiple frequencies, with better than -60 dBc third order intermodulation distortion (IMD). It is designed for use in an amplifier system that is modular in design, and is ideally suited for use in AMPS/TDMA/CDMA/CDPD/W-CDMA base stations. The plug-in Model G3S-800-180-029 amplifier modules can each provide 180 watts of power nominally (210 W max.) and function completely independently of each other. The amplifier modules are designed for parallel operation to produce high peak power output and system redundancy for remote applications, when installed in multi-module amplifier subracks manufactured by Powerwave. All solid-state, the system is designed to provide trouble-free operation with minimum maintenance. The system's modular construction and unique and highly effective LED-based operational status and fault indicators help minimize downtime. The turn-on and turn-off sequences of voltages are fully automatic, as is overload protection and recycling. Inadvertent operator damage from front panel manipulation is virtually impossible. The amplifier module has a status connector that allows the host system to monitor the amplifier module’s status. The front panel of each amplifier module has unit level status/fault indicators and an RF on/off/reset switch. Primary power for the amplifier is +27 Vdc. Cooling for each plug-in amplifier module is provided by four fans, two mounted on the front and two on the rear of the module. The fans draw outside air through the front of the module and exhaust hot air out through the rear of the module. 1-3 Functional And Physical Specifications Functional and physical specifications for the amplifier are listed in table 1-2. 1-4 Equipment Changes Powerwave Technologies, Inc. reserves the right to make minor changes to the equipment, including but not necessarily limited to component substitution and circuitry changes. Changes that impact this manual may subsequently be incorporated in a later revision of this manual. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved All specifications are subject to change without notice. Contact the factory for complete performance data. 044-05112 Rev. A 1-1 April 2002 G3S-800-180-029 Installation & Service Manual 1-5 Ordering Information Table 1-1 following gives the part numbers and descriptions to be used when ordering either an entire amplifier or replacement fans. Table 1-1 Major Amplifier Components Model Number G3S-800-180-029 800-01075-003 800-00972-002 Description 180 W 869-894 MHz MCPA Module Front fan assembly Rear fan assembly. Table 1-2 G3S-800-180-029 Multicarrier Cellular Amplifier Functional Specifications Frequency Range Instantaneous Bandwidth Total Typical / Maximum Input Power Total Output Power IMD and In-band Spurious, mean measurement, 30 KHz bandwidth@ +26 to +28Vdc, 25°C Out of Band Spurious & Noise, measured in 30 KHz BW RF Gain Gain Flatness: Gain Variation w/ Voltage and Frequency Gain Variation Over Temperature: Noise Figure Output Protection: Input Port Return Loss: Harmonics: Out of Band Spurious: Duty Cycle: DC Input Power: DC Circuit Breaker Rating Operating Temperature: Storage Temperature: Operating Humidity: Storage Humidity: DC Input, Summary Alarm, and RF Input / Output Connectors: Heat Generation Weight Dimensions: Electrical Service Recommendations Circuit Breakers 869-894 MHz (25 MHz Bandwidth) 25 MHz -5.44 / -5.0 dBm 180 W (52.55 dBm) Nominal, 210 W (53.22 dBm) Max. (1 Module) -60 dBc or -16 dBm max @ up to 16 equal power CW tones with a combined maximum power of P0 with a max single carrier power of P0/16. -60 dBc max @ +26 to +28 Vdc 58 dB +0.5 dB ±0.5 dB @ 27 Vdc ±1 Vdc + 0.5 dB; 26 to 28 Vdc ±0.5 dB 28 dB max Mismatch Protected 16 dB min Better than -50 dBc Better than -60 dBc Continuous +27 Vdc ±1 Vdc, 62 amps typical (70 amps max) Operational +21.7 Vdc to 30 Vdc (Po derated outside normal operating range) 100 Amps 0 ºC to +40 ºC -40 ºC to +85 ºC 0 % to 80 % Relative Humidity (noncondensing) 0 % to 100 % Relative Humidity (noncondensing) 21-Pin D-Subminiature Combo Connector plus singlepin D-Sub connector for additional DC capability. 4852 BTUs @ 26 VDC, Po = 180 W (1 Amplifier) 50 lbs. 5.20” High, 17.00” Wide, 20.00” Deep Capable of handling anticipated inrush current (normally 25% over equipment maximum current draw), in a load center with a master switch. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved All specifications are subject to change without notice. Contact the factory for complete performance data. 044-05112 Rev. A 1-2 April 2002 G3S-800-180-029 Installation & Service Manual Figure 1-1 G3S-800-180-029 Copyright Powerwave Technologies, Inc., April 2002. All rights reserved All specifications are subject to change without notice. Contact the factory for complete performance data. 044-05112 Rev. A 1-3 April 2002 G3S-800-180-029 Installation & Service Manual Section 2 Installation 2-1 Introduction This section contains installation recommendations, unpacking, inspection, and installation instructions for the Multicarrier Cellular Amplifier. Carefully read all material in this section prior to equipment unpacking or installation. Also read and review the operating procedures in Section 3 prior to installing the equipment. It is important that the licensee perform these tasks correctly and in good faith. If applicable, carefully review the Federal Communications Commission (FCC) rules as they apply to your installation. DON'T TAKE CHANCES WITH YOUR LICENSE. 2-2 Electrical Service Recommendations Powerwave Technologies recommends that proper AC line conditioning and surge suppression be provided on the primary AC input to the +27 Vdc power source. All electrical service should be installed in accordance with the National Electrical Code, any applicable state or local codes, and good engineering practice. Special consideration should be given to lightning protection of all systems in view of the vulnerability of most transmitter sites to lightning. Lightning arrestors are recommended in the service entrance. Straight, short ground runs are recommended. The electrical service must be well grounded. Each amplifier system should have its own circuit breaker, so a failure in one does not shut off the whole installation. Circuit breakers should be capable of handling the anticipated inrush current, in a load center with a master switch. Powerwave recommends that a 100 amp circuit breaker be installed in the power distribution unit for each amplifier. DC wire smaller than 2 AWG 90°C copper DC should not be installed. Each amplifier should have its own DC cable pair. See table 2-1. CAUTION This table and the foregoing are provided as guidelines. Follow the appropriate NEC standards in your area and the cable manufacturer’s recommendation for proper cable selection. Table 2-1 Sample of DC Cable Ratings AWG or Copper 3 Cond. In Raceway Aluminum Single Conductor In Free Air 3 Cond. In Raceway Single Conductor In Free Air MCM 90°C 110°C 90°C 110°C 125°C 200°C 90°C 110°C 90°C 110°C 14 25 30 30 40 40 45 -- -- -- -- -- -- 12 30 35 40 50 50 55 25 25 30 40 40 45 10 40 45 55 65 70 75 30 35 45 50 55 60 55 60 75 85 90 100 40 45 55 65 70 80 70 80 100 120 125 135 55 60 80 95 100 105 125°C 200°C 95 105 135 160 170 180 75 80 105 125 135 140 125 135 185 210 225 240 100 105 140 165 175 185 145 160 215 245 265 280 110 125 165 190 205 220 165 190 250 285 305 325 130 150 190 220 240 255 Based on ambient temperature of 30°C (86°F) 100% Load Factor Source: Industrial Electric Wire & Cable Inc., Technical Guide Vol. 4M 11/99, Table III Suggested Ampacities - All Types of Insulations; Based on National Electric Code Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 2-1 April 2002 G3S-800-180-029 Installation & Service Manual According to the laws of probability used to formulate Erlang tables, rarely are all channels transmitting at the same time. We can use Erlang tables to predict typical maximum current usage. Table 2-2 describes the current load for a 3 sector (70%), 2 sector (80%) and omni (90%) site. Based on this table, an 800 amp power plant may suffice. Battery backup or UPS systems should be installed in remote sites or in sites which experience brownout conditions or generator switchovers. Adding this equipment should eliminate the need for site visits by technicians after brownouts or power outages. Battery backup systems also provide excellent DC filtering as a side benefit. Table 2-2 Averaged DC Current Load (Amperes) (typical, based on % of output power) Amplifier Power No. Of 3 Sector (70%) 2 Sector (80%) 1 Sector (90%) Amplifiers Averaged Current Averaged Current Averaged Current 180 180 180 180 484 323 161 54 334 167 56 176 59 100% Typical 554 370 185 62 2-3 Air Conditioning Each G3S-800-180-029 amplifier generates 4852 BTUs of heat at full power. A fully populated MCR30829-1-3 subrack operating at full power will generate 14,556 BTUs of heat. A full threesector site employing three fully populated MCR30829-1-3 subracks will generate 52,510 BTUs of heat at full power (500W per subrack, 70A, 27VDC). A five-ton air conditioner is needed to cool this Powerwave equipment. A full three-sector site probably needs at least a five-ton air conditioner to cool all of the site's equipment, based on heat load averaging as described in table 2-2. In keeping with section 2-3, table 2-3 describes the heat load for a 3 sector (70%), 2 sector (80%) and omni (90%) site. Perform a site survey to determine actual air conditioning needs. Table 2-3 Averaged Heat Loading (British Thermal Units/hr) (typical, based on % of output power) Amplifier Power No. Of Amplifiers 3 Sector (70%) Averaged BTU's 180 180 180 180 38,973 25,982 12,991 4,330 2 Sector (80%) Averaged BTU's 26,735 13,368 4,456 1 Sector (90%) Averaged BTU's 100% Typical 13,961 4,654 43,666 29,111 14,555 4852 2-4 Unpacking And Inspection This equipment has been operated, tested and calibrated at the factory. Only in the event of severe shocks or other mistreatment should any substantial readjustment be required. Carefully open the container(s) and remove the amplifier module(s). Retain all packing material that can be reassembled in the event that the unit must be returned to the factory. CAUTION Exercise care in handling equipment during inspection to prevent damage caused by rough or careless handling. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 2-2 April 2002 G3S-800-180-029 Installation & Service Manual Visually inspect the amplifier module for damage that may have occurred during shipment. Check for evidence of water damage, bent or warped chassis, loose screws or nuts, or extraneous packing material in the connector or fans. Inspect the rear panel connector for bent connector pins. If the equipment is damaged, a claim should be filed with the carrier once the extent of any damage is assessed. We cannot stress too strongly the importance of IMMEDIATE careful inspection of the equipment and the subsequent IMMEDIATE filing of the necessary claims against the carrier if necessary. If possible, inspect the equipment in the presence of the delivery person. If the equipment is damaged, the carrier is your first area of recourse. If the equipment is damaged and must be returned to the factory, write or phone for a return authorization. Powerwave may not accept returns without a return authorization. Claims for loss or damage may not be withheld from any payment to Powerwave, nor may any payment due be withheld pending the outcome thereof. WE CANNOT GUARANTEE THE FREIGHT CARRIER'S PERFORMANCE. 2-5 Installation Instructions (refer to figures 1-1 and 2-1) The G3S-800-180-029 amplifier module is designed for installation in a subrack for connection of DC power, RF, and monitor cables. To install the amplifier proceed as follows: 1. Install the subrack in an equipment rack and secure in place, based on the installation instructions from the appropriate manual for the subrack being installed. 2. Connect the subrack RF output to a high quality transmit filter. Powerwave recommends that a 800W average power / 14KW instantaneous peak power rated filter be used in most applications. 3. Connect the combined transceiver output(s) to the RF Input port of subrack. 4. Connect the alarm cable(s) to the alarm port of subrack. WARNING Verify that all circuit breaker switches on the power distribution panel are in the OFF position. Turn off external primary DC power before connecting DC power cables. 5. Connect positive primary power and negative primary power to the subrack. Tighten the subrack power connections. 6. Verify that the plug-in amplifier’s front panel On/Off switch is in the Off position. 7. Inspect the 21-pin D-Sub male combo connector on the rear of each amplifier before installing the amplifier in the amplifier subrack. Verify that all pins are straight, no pins are recessed, that the alignment shield is not bent, and no packing material is embedded in the connector. CAUTION Forcing the amplifier into the subrack at too fast a rate may cause the pins on the 21-pin D-sub connector of the amplifier to become recessed or broken. 8. Install the plug-in amplifier module(s) in the subrack. Tighten left and right thumbscrews until finger tight. Tighten the thumbscrews with a slotted screw driver about 1/8 of a turn past finger tight. 9. Check your work before applying DC voltage to the system. Make certain all connections are tight and correct. 10. Turn the power distribution circuit breakers back on. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 2-3 April 2002 G3S-800-180-029 Installation & Service Manual 11. Measure primary DC input voltage. DC input voltage should be +27 Vdc ±1.0 Vdc. If the DC input voltage is above or below the limits, call and consult Powerwave before you turn on your amplifier system. 12. Refer to section 3 for initial turn-on and checkout procedures. 2-6 Amplifier Module Connectors The amplifier has three connectors on the right rear of the module. The larger is a 21-pin male D-Sub combo, which provides the status, alarm, control, and power connections. The smaller BMA coaxial female connectors provide the RF connections. Refer to figure 2-1. Figure 2-1 G3S-800-180-029 Amplifier, Rear View 2-6.1 Amplifier Module Status, Alarm, Control, And Power Connector The amplifier has a separate remote alarm and control connector, which may be used by the host system to monitor and control the individual amplifier modules. The status, alarm, control, and power connections on the amplifier connector are made through a 21-pin male D-Sub combo connector (figure 2-2) and are listed and described in table 2-4. A1 2 3 4 5 6 7 8 9 A3 A2 A4 10 11 12 13 14 15 16 17 Figure 2-2 DC and Logic Connector (on Rear of G3S-800-180-029 Amplifier Module) Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 2-4 April 2002 G3S-800-180-029 Installation & Service Manual Table 2-4 Amplifier Module DC and Logic Connector Definition Pin Function Description A1 A2 A3 A4 Power Input Power Input Ground Ground RS485 +TxD RS485 +RxD Service Loop MCPA Disabled (Summary Fault) 10 11 12 13 14 Mod Addr 0 Mod Addr 1 TP1 Manual Download DC on stat RS485 –TxD RS485 –RxD SCL7 SDA7 FP Disable Output 15 FP RST 16 17 GND Module Detect +27 Vdc (Power Contact) +27 Vdc (Power Contact) Ground (Power Contact) Ground (Power Contact) Serial Communication Data Out Serial Communication Data In TTL input to Amp. Gnd. for special test mode (Note 1) TTL signal normally low indicates MCPA enabled. A high level indicates that the MCPA has been disabled. Over Power, Over Voltage takes one second to activate the signal. TTL input to Amp. Gnd. supplied by shelf to identify slot. TTL input to Amp. Gnd. supplied by shelf to identify slot. TTL output. Future test point. GND to download manually TTL output. High indicates Amp is powered on. Serial Communication Data Out Serial Communication Data In No connection No connection Output, GND if the front panel switch is in the OFF position; +5 volts indicates the front panel switch is in the ON position. Output, GND if the front panel switch is in the RESET position; +5 volts otherwise. Ground Ground potential. Informs the subrack that an MCPA is plugged in. Note 1: Service loop grounded allows the MCPA to be enabled or disabled by the front panel switch when not mounted in the shelf. 2-6.2 Amplifier Module RF Connector The amplifier has separate RF connectors, which are used for the RF signal input and output. The RF connections on the amplifier connector are made through two BMA female coaxial connectors (figure 2-3) and are listed and described in table 2-5. A1 A2 Figure 2-3 Amplifier RF Connector Table 2-5 Amplifier RF Connector Definition Pin A1 A2 Function RF Input RF Output Description BMA Coaxial Female, Radiall BMA Coaxial Female, Radiall Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 2-5 April 2002 G3S-800-180-029 Installation & Service Manual Section 3 Operating Instructions 3-1 Introduction This section contains operating instructions for the Multicarrier Cellular Amplifier System. 3-2 Location And Function Of Amplifier Module Controls And Indicators Primary +27 Vdc power is applied to the amplifier via a 100-amp circuit breaker (ON-OFF) located on the left side of the amplifier front panel. The plug-in amplifier module RF control and indicators, located in the center of the amplifier front panel between the cooling fans, are shown in figure 3-1. The status and RF control functions and alarms are described in detail in the subsequent paragraphs. Figure 3-1 G3S-800-180-029 Amplifier Module RF Control and Indicators 3-2.1 Voltage Indicators And On/Off/Reset Switch 3-2.1.1 On Off Switch This is the DC power switch for the amplifier module. The On/Off switch is a circuit breaker rated for the inrush current and maximum current draw allowable with this amplifier module. This switch should be in the Off position whenever the amplifier is inserted or removed from an amplifier subrack. 3-2.1.2 RF ON Switch Three position switch: Off (down position) - Turns off RF section of amplifier module. On (center position) - Normal amplifier on position. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 3-1 April 2002 G3S-800-180-029 Installation & Service Manual Reset (up position) - When toggled to reset position, all the red LED indicators will turn on one at a time in sequence followed by all the green indicators one at a time in sequence; this will also reset the fault latches. If the switch is held in the reset position, a microcontroller reset will occur. This will be verified by the LEDs toggling state again. The switch is spring loaded to return to the normal ON position when released. If a fault occurs and the MCPA is disabled, the alarms can be cleared and the MCPA enabled by this reset position. The functions of the switch are disabled for five seconds after a power-up condition. 3-2.1.3 +27VDC Indicator Green LED. When lit, indicates that the +27 Vdc supply is greater than +21 Vdc and less than +31 Vdc. If the +27 Vdc indicator goes out, the DC FAIL indicator will illuminate. This indicates that the +27 Vdc voltage dropped below +21 Vdc. 3-2.1.4 +15VDC Indicator Green LED. When lit, indicates that the +15 Vdc supply is greater than +12 Vdc and less than +17 Vdc. If the +15 Vdc indicator goes out, the DC FAIL indicator will illuminate. This indicates that the +15 Vdc voltage dropped below +12 Vdc or increased above +17 Vdc. 3-2.1.5 +5VDC Indicator Green LED. When lit, indicates that the +5 Vdc supply is greater than +2 Vdc and less than +7 Vdc. If the +5 Vdc indicator goes out, the DC FAIL indicator will illuminate. This indicates that the +5 Vdc voltage dropped below +2 Vdc or increased above +7 Vdc. 3-2.1.6 -5VDC Indicator Green LED. When lit, indicates that the -5 Vdc supply is greater than -7 Vdc and less than -2 Vdc. If the -5 Vdc indicator goes out, the DC FAIL indicator will illuminate. This indicates that the -5 Vdc voltage dropped below -7 Vdc or increased above -2 Vdc. 3-2.2 Alarm Indicators The alarm modes described here are indicative of amplifier alarm modes made to the amplifier subrack. The amplifier subrack interprets these alarms and may subsequently deliver a different alarm indication to the host equipment. Refer to the amplifier subrack manual to determine host equipment level alarms. Refer to section 6 to interpret and correct the various alarm states. Refer to table 3-1. A ‘Minor Alarm’ indicates a potential fatal amplifier problem via the amplifier front panel LEDs. and the MCPA fault will be in evaluation. A ‘Major Alarm’ indicates a major problem but the MCPA module will not be disabled. A ‘Critical Alarm’ is indicative of a fatal problem. The fault indicator will latch on and the MCPA module will be disabled. Both ‘Major Alarm’ and ‘Critical Alarm’ will be sent to the host system via the MCPA subrack. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 3-2 April 2002 G3S-800-180-029 Installation & Service Manual Table 3-1 Amplifier Module Alarm Indicators Definition Alarm Mode LED MCPA Disable signal Condition Module (pin 4 inTable 2-1) Over Pwr Critical Red Disable High Over Pwr Critical High Temp Minor Red Red Disable Enable High Low High Temp Critical Red Disable High MCPA MCPA module output power >220 watts (Note 4) Input power >-3 dBm High temperature detected High temperature detected for longer than two minutes 14.5 W < Reflected Power < 38W 60W < Reflected power detected at output longer than approx. two min. One of the internal DC voltages dropped below or exceeded the safe threshold level Voltage out of range for longer than approx. two minutes (Note 2) +27 Vdc input >30 V for longer than one sec. after initial detection of DC input >31 V (Note 3) VSWR Minor Red Enable Low VSWR Critical Red Disable High DC Fail Minor Red Enable Low DC Fail Critical Red Disable High Critical Red Disable High Major Red Enable Low Any fan failure Minor Red Enable Low Loop Fail Critical Red Disable High Low Pwr Minor Red Enable Low Low Pwr Critical Red Disable High LPA DISAB. Critical Red Disable High Loop failure detected Loop failure detected longer than 2 minutes Rack controller detected MCPA output is 3 dB below that of the other MCPA in the system. Rack controller detected low power condition for more than approx. two minutes Unit is manually switched off using the front panel RF ON switch, or disabled by a serial command or auto shutdown by an alarm condition. DC Fail (Over voltage) Fan Fail (one) Loop Fail NOTES: 1. RS-485 serial alarm will follow LED status. 2. The appropriate status LED shall turn off indicating which voltage is out of its range. 3. When overvoltage is detected: a) MCPA shall shut down (disable) b) Turn on red DC Fail LED c) Set flag for DC Fail alarm 4. When overpower is detected: a) MCPA shall shut down (disable) b) Turn on Over Pwr LED c) Set flag for Over Pwr alarm d) The MCPA module uses an RMS power detector to determine the overpower fault. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 3-3 April 2002 G3S-800-180-029 Installation & Service Manual 3-3 Initial Start-Up And Operating Procedures The amplifier module has two operating controls, both located on the front face of the module: the power ON - OFF switch and the RF ON - ON/OFF/RESET switch (refer to figures 1-1 and 3-1). To perform the initial start-up, proceed as follows: 1. Verify that all input and output cables are properly connected. CAUTION Before applying power, make sure that the input and output of the amplifier are properly terminated at 50 ohms. Do not operate the amplifier without a load attached. Refer to table 1-2 for input power requirements. Excessive input power may damage the amplifier WARNING Ensure the amplifier is turned off while disconnecting and reconnecting cables between the antenna interface and power measurement equipment. Failure to do so may cause damage to the equipment or personal injury. NOTE The output coaxial cable between the amplifier and the antenna must be 50 ohm coaxial cable. Use of any other cable will distort the output. 2. Verify that the amplifier front panel switches are in the OFF position. 3. Turn on supply that provides +27 Vdc to the amplifier system. Do not apply an RF signal to the amplifier system 4. Place the ON - OFF circuit breaker on the amplifier in the ON position. Visually check the indicators on the amplifier module, and verify that the following indicators are on: A. LPA DISAB. indicator (red) should be on. B. The +27VDC, +15VDC, +5VDC and -5VDC indicators (green) on the amplifier module should be on. 5. Set the RF ON switch to the ON (center) position. All red LEDs should turn off after six seconds. 6. Follow the power setting procedure set forth in the amplifier subrack or system integration manual. Turn on external exciter/transceiver and apply RF input signals. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 3-4 April 2002 G3S-800-180-029 Installation & Service Manual Section 4 Principles of Operation 4-1 Introduction This section contains a functional description of the Multicarrier Cellular Amplifier. 4-2 RF Input Signal This amplifier may be installed in a base station system as either a stand-alone module (i.e. in a micro-cell application), or combined with multiple amplifiers in a combining subrack product available from Powerwave. In either case, the maximum input power for all carrier frequencies should not exceed the limits specified in table 1-2. For proper amplifier loop balance and to ensure compliance with FCC rules, the out of band components of the input signals should not exceed -40 dBc. The input VSWR presented to the amplifier should be 2:1 (or better) to maximize the transfer of input power to the amplifier; this is particularly important when the amplifier is not installed in a Powerwave manufactured combining subrack. 4-3 RF Output Load The load impedance should be as good as possible (1.5:1 or better) in the working band for good power transfer to the load. If the amplifier is operated into a filter, it will maintain its distortion characteristics outside the signal band. 4-4 G3S-800-180-029 Amplifier Module The G3S-800-180-029 amplifier is a linear, feed-forward power amplifier that operates in the 25 MHz frequency band from 869 MHz to 894 MHz. The amplifier modules are designed for parallel operation to achieve high peak power output, and provide system redundancy when installed in multi-module amplifier subracks manufactured by Powerwave. The Powerwave amplifier system is ideally suited for unmanned remote locations. The amplifier module, figure 4-1, has an average output of 180 watts nominal power (1800 watts peak power) with intermodulation products suppressed to better than -60 dBc below carrier levels. The amplifier provides an amplified output signal with constant gain and phase. Constant gain and phase is maintained by continuously comparing active paths with passive references, and correcting for small variations through the RF feedback controls. All gain and phase variations, for example those due to temperature, are reduced to the passive reference variations. Each amplifier module has an alarm and display board that monitors the amplifier performance. If a failure or fault occurs in an amplifier module, it is displayed on the individual amplifier front panel. The amplifier module is comprised of: Predistorter Pre-amplifiers Main amplifier Error amplifier Two feed-forward loops with phase-shift and gain controls DC/DC power regulator Alarm monitoring, control and display panel The main amplifier employs class AB amplification for maximum efficiency. The error amplifier and feed forward loops are employed to correct signal nonlinearities introduced by the class AB main amplifier. The error amplifier operates in class AB mode. The RF input signals are ampli Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 4-1 April 2002 G3S-800-180-029 Installation & Service Manual fied by a preamp and coupled to an attenuator and phase shifter in the first feed-forward loop. The main signal is phase shifted by 180 degrees and amplified in the premain amplifier. The output from the premain amplifier is fed to the class AB main amplifier. The output from the main amplifier is typically 220 watts. The signal is output to several couplers and a delay structure. The signal output from the main amplifier is sampled using a coupler, and the sample signal is combined with the main input signal and input to the second feed-forward loop. The error signal is attenuated, phase shifted 180 degrees, then fed to the error amplifier where it is amplified to a level identical to the sampled output from the main amplifier. The output from the error amplifier is then coupled back and added to the output from the main amplifier. The control loops continuously make adjustments to cancel out any distortion in the final output signals. 1st Loop Phase & Gain Pre Dist Pre Main FWD PWR Pre Amp 2nd Loop Phase & Gain Delay RF Out Main Amp Delay -30dB -10dB RFL PWR Error Amp Feed Forward Loop control +15 +5 -5 +27VDC Power Supply Alarms & Display Front Panel Smart Rack Figure 4-1 G3S-800-180-029 Power Amplifier Module Functional Block Diagram 4-4.1 Main Amplifier The input and output of the amplifier employ two-stage, class AB amplifiers which provide approximately 32 dB of gain in the 25 MHz frequency band from 869 to 894 MHz. The amplifier operates on +27 Vdc, and a bias voltage of +5 Vdc, and is mounted directly on a heat sink that is temperature monitored by a thermostat. If the heat sink temperature exceeds 90° C, a high temperature fault occurs. The alarm logic controls the +5 Vdc bias voltage that shuts down the amplifier. 4-4.2 Error Amplifier st The main function of the error amplifier is to amplify the distortion signal generated by the 1 Loop, to a level that cancels out the distortion and IMD when the error signal is coupled onto the main signal at the amplifier output. The error amplifier is a balanced multistage, class AB amplifier. 4-4.3 Amplifier Monitoring In the main and error amplifier modules, all normal variations are automatically compensated for by the feedforward loop control. However, when large variations occur beyond the adjustment range of the loop control, a loop fault will occur. The alarms are displayed on the front panel indicators and output via a 21-pin connector on the rear of the module to the subrack summary board Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 4-2 April 2002 G3S-800-180-029 Installation & Service Manual for subsequent remote monitoring via the ALARMS connector. Refer to paragraph 2-6 as well as figure 2-2 and table 2-3 for a description of the ALARMS connector. 4-4.4 Amplifier Module Cooling Although each amplifier module contains its own heat sink, it is cooled with forced air. Four fans are used for forced air-cooling and redundancy. The fans, located on the front and rear of the amplifier module, draw air in through the front of the amplifier and exhaust hot air out the back of the module. The fans are field replaceable. 4-5 Power Distribution Primary DC power for the system is provided by the host system to the MCR30829-1-3 Series or compatible subrack. The subrack supplies each amplifier module with +27 Vdc directly and via the RF power splitter/combiner. The amplifier module has a DC/DC converter that converts the +27 Vdc to +15 Vdc, +5 Vdc and -5 Vdc. 4-6 Intermodulation The G3S-800-180-029 amplifier is designed to deliver a 180-watt nominal composite average power (210 W max.), multi-carrier signal, occupying a bandwidth less than or equal to 25 MHz, in the band from 869 to 894 MHz. The maximum average power for linear operation, and thus the amplifier efficiency, will depend on the type of signal amplified. Three or more CW tones of equal input power will lower individual intermodulation products. If the frequencies are not equally spaced, the level of intermodulation products gets very low. When the frequencies are equally spaced, those products fall on top of each other on the same frequency grid. The average power of all intermodulation beats falling on the same frequency is called the composite intermodulation; it is -60 dBc or better. 4-7 Alarms The presence of several plug-in amplifier alarms can be detected at the DC and logic connector on the amplifier rear panel. Refer to table 2-3 and figure 2-2 for a description of the connector. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 4-3 April 2002 G3S-800-180-029 Installation & Service Manual Section 5 Maintenance 5-1 Introduction This section contains periodic maintenance and performance test procedures for the Multicarrier Cellular Amplifier. It also contains a list of test equipment required to perform the identified tasks. NOTE Check your sales order and equipment warranty before attempting to service or repair the unit. Do not break the seals on equipment under warranty or the warranty will be null and void. Do not return equipment for warranty or repair service until proper shipping instructions are received from the factory. 5-2 Periodic Maintenance Periodic maintenance requirements are listed in table 5-1. Table 5-1 also lists the intervals at which the tasks should be performed. WARNING Wear proper eye protection to avoid eye injury when using compressed air. Table 5-1 Periodic Maintenance Task Cleaning Air Vents Inspection Cables and Connectors Performance Tests Interval Action 30 Days Inspect and clean per paragraph 5-4 12 Months Inspect signal and power cables for frayed insulation. Check RF connectors to be sure that they are tight. Perform annual test per paragraph 5-5. 12 Months 5-3 Test Equipment Required For Test Test equipment required to test the amplifier system is listed in table 5-2. Equivalent test equipment may be substituted for any item, keeping in mind that a thermistor type power meter is required. NOTE All RF test equipment must be calibrated to 0.05 dB resolution. Any deviation from the nominal attenuation must be accounted for and factored into all output readings. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 5-1 April 2002 G3S-800-180-029 Installation & Service Manual Table 5-2 Test Equipment Required Nomenclature Signal Generator 30 dB Attenuator, 500 Watt 20 dB Attenuator, 20 Watt (2 each) Spectrum Analyzer Coax Directional Coupler Power Meter/Sensor Network Analyzer Current Probe Manufacturer RDL Weinschel Corp. Tenuline Model IMD-801D-03A 53-30-34 H.P. H.P. H.P. H.P. 8560E 778D 437B/8481A 8753C 5-4 Cleaning Air Inlets/Outlets The air inlets and outlets should be cleaned every 30 days. If the equipment is operated in a severe dust environment, they should be cleaned more often as necessary. Turn off DC power source before removing fans. If dust and dirt are allowed to accumulate, the cooling efficiency may be diminished. Using either compressed air or a brush with soft bristles, loosen and remove accumulated dust and dirt from the air inlet panels. 5-5 Performance Test Performance testing should be conducted every 12 months to ensure that the amplifier system meets the operational specifications listed in table 5-3. Also verify system performance after any amplifier module is replaced in the field. The test equipment required to perform the testing is listed in table 5-2, and the test setup is shown in figure 5-1. NOTE The frequencies used in this test are typical for an amplifier with a 25 MHz band from 869 MHz to 894 MHz. Select evenly spaced F1, F2, F3, and F4 frequencies that cover the instantaneous bandwidth of your system. 5-5.1 Amplifier System Performance Test This test is applicable to the G3S-800-180-029 amplifier modules. To perform the test, proceed as follows: 1. Connect test equipment to the amplifier as shown in figure 5-1. NOTE Do not apply any RF signals at this time. Turn on signal generator and set frequency F1 to 880 MHz, F2 to 883 MHz, F3 to 886 MHz, and F4 to 889 MHz. Adjust each signal generator output so that the sum power output from all four signal generators equals -6 dBm at the input. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 5-2 April 2002 G3S-800-180-029 Installation & Service Manual 20 dB Directional Coupler Unit Under Test +27 Vdc Gnd 30 dB Attenuator 20 dB Attenuator 500 W 20 W RF Out G3S-800-180 Plug-in Amplifier Module Power Meter RF In 1:2 Splitter Spectrum Analyzer 8651E Network Analyzer 8753C Filter / Isolator Signal Generator Sensor Head 8482A Sensor Head 8482A Power Meter Figure 5-1 Amplifier System Test Setup Diagram 5-5.1.1 Amplifier IMD Test And Current Test 2. Adjust attenuator for an input signal at -10 dBm. Turn on the amplifier by setting RF ON switch of amplifier. Adjust variable attenuator to set amplifier power output on power meter to 180 watts. Measure IMD on spectrum analyzer. IMD should be -60 dBc max. Record test data in table 5-3. Set RF ON switch to OFF. 3. With the amplifier module set at 180 watts power output, use the current probe (magnetic field type) and measure the dc current flow from the +27 Vdc power source. Current should be 70 amps maximum. Record test data in table 5-3. 5-5.1.2 Gain Test 4. Disconnect spectrum analyzer from test setup, and connect the network analyzer. 5. Set network analyzer as follows: Ø Power output to -10 dBm. Ø Frequency start to 869 MHz. Ø Frequency stop to 894 MHz. Ø Normalize the network analyzer for gain and return loss. 6. Check the gain across the band from 869 MHz to 894 MHz. Gain should be between 58 dB. Record test data in table 5-3. 5-5.1.3 Harmonics Test 7. With the power set at 180 watts power output, use the spectrum analyzer and check the frequency band from 869 MHz to 894 MHz for harmonics. Harmonics should be 5 dBm maximum. Record test data in table 5-3. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 5-3 April 2002 G3S-800-180-029 Installation & Service Manual 5-5.1.4 Spurious Test 8. With the power amplifier set at 180 watts power output, use the spectrum analyzer and check the frequency band from 869 MHz to 894 MHz for spurious signals. Spurious signals should be -60 dBc maximum. Record test data in table 5-3. 5-5.1.5 Input Return Loss Test 9. Reset and turn on amplifier module. Read and record the S11 return loss measurement on network analyzer. Input return loss should be –16 dB maximum. Record test data in table 5-3. Table 5-3 Multicarrier Cellular Amplifier Test Data Sheet DATE _________________________________ AMPLIFIER S/N _________________________ TEST CONDITIONS: Load and Source Impedance: 50 Ohms VSWR: < 1.2:1 Supply Voltage: +27 Vdc ±1.0 Vdc TEST 4-TONE IMD RF Gain Gain Flatness Harmonics Spurious Input Return Loss DC Power SPECIFICATION Vcc = 27 Vdc PO = 180 W Freq.: 880, 883, 886, and 889 MHz Vcc = 27 Vdc PO = 180 W Freq. = 880 MHz Vcc = 27 Vdc ±1 Vdc PO =180 W 869-894 MHz Band Vcc = 27 Vdc PO = 180 W 869-894 MHz Band Vcc = 27 Vdc PO =180 W 869-894 MHz Band Vcc = 27 Vdc PO = 180 W 869-894 MHz Band Vcc = 27 Vdc PO = 180 W 4 Tones MIN MAX DATA -60 dBc 57.5 dB 58.5 dB -0.5 dB +0.5 dB 5 dBm -60 dBc -16 dB 70 Amps PASS _________________________________ FAIL _______________________________ Tested by ______________________________ Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 5-4 April 2002 G3S-800-180-029 Installation & Service Manual 5-6 Field Replaceable Parts And Modules The following parts and modules can be replaced in the field on site by a qualified technician with experience maintaining RF power amplifiers and similar equipment: 1. G3S-800-180-029 power amplifier modules 2. Cooling fans 5-6.1 G3S-800-180-029 Power Amplifier Module To replace a power amplifier module, proceed as follows: 1. Set both the RF ON On/Off/Reset switch and the power ON/OFF switch on the front panel of the amplifier module to OFF. 2. Loosen two screws that secure amplifier module to subrack. CAUTION The amplifier is equipped with a spring clip on each side panel to prevent the amplifier from being fully removed from the subrack via the front panel handles. When removing the amplifier from the subrack, it is very important to support the amplifier such that the rear of the module does not suddenly drop when it disengages from the track. A drop such as this could damage the module or cause personal injury. Spring Clip Figure 5-2 Amplifier Spring Clip Location 3. Use the handle on the front of the module, and with a steady even pressure, gently pull the module about half way out of subrack until the spring-clips prevent the amplifier from being removed (refer to figure 5-2). 4. Simultaneously press the front half of each spring clip towards the center of the amplifier and resume removal of the amplifier. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 5-5 April 2002 G3S-800-180-029 Installation & Service Manual 5-6.2 Cooling Fans To replace a front cooling fan, proceed as follows: 1. Loosen four snap fasteners that secure fan to amplifier module. Disconnect fan power connector from amplifier module. To replace a rear cooling fan, proceed as follows: 1. Remove amplifier module from subrack; see paragraph 5-6.1 preceding. 1. Loosen the four Phillips head screws that secure the fan to the amplifier module. Disconnect the fan power connector from the amplifier module. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 5-6 April 2002 G3S-800-180-029 Installation & Service Manual Section 6 Troubleshooting 6-1 Introduction This section contains a list of problems and a few suggested actions that may correct the problem. If the suggested corrective action does not eliminate the problem, please contact your Powerwave field representative or the factory for further instructions. NOTE Check your sales order and equipment warranty before attempting to service or repair the unit. Do not break the seals on equipment under warranty or the warranty will be null and void. Do not return equipment for warranty or repair service until proper shipping instructions are received from the factory. 6-2 Troubleshooting The following are general guidelines established to aid Field Engineers or Cell Site Technicians in the proper method of Powerwave equipment fault resolution by fault mode. 6-2.1 DC Voltage Indicators Not Illuminated 1. Check the front panel ON/OFF switch. 2. Check the power plant circuit breaker. 3. Check for +27 + 1.0 VDC at the amplifier subrack input. 4. A. If the voltage is low, verify that all DC connections between the power plant and the amplifier subrack are tight. B. If the voltage is correct, 1. Remove the amplifier from the subrack slot and move the amplifier to another amplifier subrack slot. 2. Check the voltage on the power pins of the mating amplifier and amplifier subrack connector. 3. Verify that the amplifier DC connections are not damaged. Return the amplifier to the factory for repair. 6-2.2 OVER PWR Illuminated or Blinking 1. If all the amplifiers in a given amplifier subrack are in Over Pwr and the LPA Disable LED is illuminate, then the input RF power level is too high and the amplifiers have been turned off. RF power may be incorrectly set during equipment commissioning. This may be due to a faulty jumper cable. Verify the amplifier subrack output cables, transmit filter, and directional coupler are in proper working order. The loss between the amplifier subrack and the hatch plate is typically less than 2.0 dB. 2. If all the amplifiers in a given amplifier subrack are in Over Pwr and the LPA Disable LED is not illuminated, then the input RF power level is too high. The amplifier subrack is attempting to maintain a safe power output level (smart subracks with True RMS power detectors and voltage variable attenuators only). RF power may be incorrectly set during equipment commissioning. This may be due to a faulty jumper cable. Verify the amplifier subrack output ca- Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 6-1 April 2002 G3S-800-180-029 Installation & Service Manual bles, transmit filter, and directional coupler are in proper working order. The loss between the amplifier subrack and the hatch plate is typically less than 2.0 dB. 3. 4. If only one or two amplifiers in a given amplifier subrack are in Over Pwr and the LPA Disable LED is blinking, then the amplifier subrack is probably in Sleep Mode (smart subracks with True RMS power detectors and voltage variable attenuators only). A. Pressing the On/Off/Reset switch momentarily in the Up position or cycling DC power on the amplifier should bring the amplifier back on-line. B. Sleep Mode firmware may be disabled in the field with a PC interface and software available from Powerwave. Move the amplifier to another slot in a different subrack, if available. Mark the amplifier with a sticker or place a tie wrap on the handle to identify the amplifier. Monitor for future failure. A. If the same amplifier fails again, return the amplifier to the factory for repair. B. If the replacement amplifier in the original subrack fails, replace the amplifier subrack. 6-2.3 HIGH TEMP Illuminated 5. 6. If an amplifier is in HIGH TEMP and the LPA Disable LED is illuminate, then the amplifier heat sink temperature is too high. This may be due to: A. High ambient temperature. B. Fan failure. C. Insufficient air-volume capacity. Most of Powerwave’s amplifiers require a certain amount of free-space to allow proper airflow. Correct the heat problem, then reset the amplifier by momentarily pressing the Reset button on the amplifier front panel up. 6-2.4 VSWR Illuminated 7. If all the amplifiers in a given amplifier subrack are in VSWR and the LPA Disable LED is illuminate, then the output RF reflected power level is too high and the amplifiers have been turned off. This may be due to a faulty jumper cable or transmit filter. Verify the amplifier subrack output cables, transmit filter, and directional coupler are in proper working order. The loss between the amplifier subrack and the hatch plate is typically less than 2.0 dB. This fault normally occurs during site or just following site power setting and normally takes about 10 to 15 minutes to reveal itself. This fault may not occur at low power levels (i.e. when just one or two channels are up). 8. If one amplifier in an amplifier subrack is in VSWR and the LPA Disable LED is illuminated, then the output RF reflected power level is too high for that amplifier. This may be due to A. A damaged or recessed amplifier RF output connector. Return the amplifier to the factory for repair. Mishandling of the amplifier normally causes recessed pins. Before installing an amplifier, look at the D-sub connector to ensure none of the pins are recessed, bent or that the outer connector shield is not damaged. When installing the amplifier, do not force the amplifier into the slot. Gentle even pressure is all that is needed to properly seat the amplifier. B. Improper seating of the amplifier. 1. Ensure the amplifier thumbscrews are properly tightened. 2. Try seating the amplifier in another subrack slot. 3. Try seating the amplifier in a subrack in another sector. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 6-2 April 2002 G3S-800-180-029 Installation & Service Manual 6-2.5 DC FAIL Illuminated If an amplifier is in DC FAIL and the LPA Disable LED is illuminate, then one of the four amplifier DC voltages is either out of tolerance or not present. Return the amplifier to the factory for repair. 6-2.6 FAN FAIL Illuminated If an amplifier is in FAN FAIL, then the one of the amplifier’s cooling fans has failed. Replace the fan. Fan failure does not cause the amplifier to shut down; amplifier shut down is determined by heat sink temperature. 6-2.7 LOOP FAIL Illuminated 9. Loop Fail is always accompanied by LPA Disable LED illuminated. This may be due to A. Inability of the amplifier to maintain a 180° phase shift between the first and second loops. B. A damaged error amplifier. This can be caused by C. 1. Out of band spurious or intermods being applied at too high of a level at the amplifier input port. An input band-pass filter may be necessary to correct this problem. 2. Disconnecting amplifier RF output cables while the amplifier is still turned on. Always turn the amplifier off when moving output RF cables from the hatch plate to test equipment and back again. Improper power balance between amplifiers in a given subrack. 1. Ensure the amplifier thumbscrews are properly tightened. Reset the amplifier by momentarily pressing the Reset button on the amplifier front panel up. 2. Try seating the amplifier in another subrack slot. 3. Try seating the amplifier in a subrack in another sector. 6-2.8 LOW PWR Illuminated Low Power is always accompanied by the LPA Disable LED illuminated. This is due to the gain of either the internal preamplifier or main amplifier being 0.5 dB (typically) or more below the amplifier specification. The amplifier should be returned to the factory. 6-2.9 LPA DISABLE Illuminated 10. LPA Disable LED illuminated indicates that the amplifier RF section is turned off. This may be due to A. An accompanied alarm indicating a critical amplifier fault (i.e. Loop Fail fault). B. A response to a subrack command, purposely inhibiting the amplifier (i.e. Sleep Mode activation) C. Improper seating of the amplifier in the subrack. 11. Ensure the amplifier thumbscrews are properly tightened. Reset the amplifier by momentarily pressing the Reset button on the amplifier front panel up. 12. Try seating the amplifier in another subrack slot. 13. Try seating the amplifier in a subrack in another sector. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 6-3 April 2002 G3S-800-180-029 Installation & Service Manual 6-3 Return For Service Procedures When returning products to Powerwave, the following procedures will ensure optimum response. 6-3.1 Obtaining An RMA A Return Material Authorization (RMA) number must be obtained prior to returning equipment to the factory for service. Please contact our Repair Department at (888) 797-9283 or (714) 4661000 to obtain this number, or FAX your request to (714) 466-5816. Failure to obtain this RMA number may result in delays in receiving repair service. 6-3.2 Repackaging For Shipment To ensure safe shipment of the amplifier, it is recommended that the package designed for the amplifier be used. The original packaging material is reusable. If it is not available, contact Powerwave’s Customer Service Department for packing materials and information. Copyright Powerwave Technologies, Inc., April 2002. All rights reserved 044-05112 Rev. A 6-4 April 2002
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Modify Date : 2002:06:03 14:56:54-07:00 Create Date : 2002:06:03 14:38:54-07:00 Title : I. GENERAL DESCRIPTION. Author : Steve Ault Creator : Microsoft Word 8.0 Producer : Acrobat Distiller 4.05 for Windows Page Count : 30EXIF Metadata provided by EXIF.tools