Powerwave Technologies 5JS0084 Fiber-Fed Repeater/Radio Head User Manual RH300000 100 A
Powerwave Technologies Inc Fiber-Fed Repeater/Radio Head RH300000 100 A
Contents
- 1. User Manual 1
- 2. User Manual 2
User Manual 1
Utfärdare/Issued by Dattum/Date Godkänd/Approved Dok nr/Doc no Rev Product Management 2006-02-09 SYKLK RH300000/100-201 A Dok namn/Doc name Fil/file PRELIMINARY PRODUCT SPECIFICATION RH300000_100_A.doc Sida/Page Wide band Radio Head CDMA1900 MHz Product Number: RH300000/100 (incl. Fibre Optical Node) 1. Electrical specification (typical values) Applicable standards: Radio Transmission and Reception FCC EMC 3GPP TS25.113 Environmental ETS 300 019-2-4 Frequency band UL CDMA Frequency band DL CDMA Gain, maximum Gain adjustment range Gain step resolution Gain variation within each relevant band Max absolute delay (excluding fibre or coaxial cable delay) Noise figure including fiber optic interface at max gain* System Fiber optical loss System Fiber optical link length System input power range Receiver input port return loss Power supply voltage AC Power supply voltage DC (optional) Power consumption max 1850 – 1910 MHz 1930 – 1990 MHz 35.7 dB > 30 dB dB <2 dB <300 ns <5 dB < 10 20 +10 to +40 dBm 14 115 - 230 21-60 210 dB km *Note! If combined with other band, expect lower output power and affected noise figure Output power* dBm/carrier DL 4 carrier 26 8 carrier 23 Input and Output Impedance = 50 Ohms Industry Canada: 20 dB gain bandwidth = 85.6 MHz dB VAC VDC Utfärdare/Issued by Dattum/Date Godkänd/Approved Dok nr/Doc no Rev Product Management 2006-02-09 SYKLK RH300000/100-201 A Dok namn/Doc name Fil/file PRELIMINARY PRODUCT SPECIFICATION RH300000_100_A.doc Sida/Page 2. Environmental specification Temperature range Casing class 3. Mechanical specification Dimensions. (W x H x D) Weight RF-connectors Lock type -13 to + 131 °F -25 to + 55 °C NEMA4/IP65 17.4 x 20.9 x 7.7 440 x 530 x 195 50 22.5 N-type female ABLOY Inches mm lbs Kg Industry Canada: The Manufacturer's rated output power of this equipment is for single carrier operation. For situations when multiple carrier signals are present, the rating would have to be reduced by 3.5 dB, especially where the output signal is reradiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. FCC CFR 47, Part 15.21 Information to user: Any changes or modifications to the equipment not expressly approved by Powerwave Technologies, Inc. could void The user's authority to operate the equipment. Powerwave Technologies, Inc. will not be responsible for such changes. Powerwave Fiber Optics Preface User’s Manual Fiber Optics – English VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 Preface Powerwave Fiber Optics This document contains descriptions of Powerwave fiber optic units. Most sections in the document do not contain comlete information for building, installation, or commissioning systems and are therefore not allowed to be used as any kind of installation or commissioning guide. Only sections specificly declared to be installation or commissioning instructions are allowed to be used for that purpose. Hardware and software mentioned in this document are subjected to continuous development and improvement. Consequently, there may be minor discrepancies between the information in the document and the performance or design of the products. Specifications, dimensions and other statements mentioned in this document are subject to changes without prior notice. Powerwave and its suppliers shall not be liable for any damages related to this product, or for any other damages whatsoever caused of the use of or inability to use any Powerwave product. This is applicable even if Powerwave has been advised of the damage risk. Under any circumstances, Powerwave's entire liability shall be limited to replace such defective software or hardware which was originally purchased from Powerwave. LinDAS is a trademark of Powerwave. Microsoft is a registered trademark of Microsoft Corporation. Windows, Windows 98, Windows NT and Windows 2000 are trademarks of Microsoft Corporation. Intel and Pentium are registered trademarks of Intel Corporation. Hayes is a registered trademark of Hayes Microcomputer Products, Inc. Other trademarks mentioned in this manual are trademarks or registered trademarks of their respective owners. Powerwave Technologies, Inc., 1801 East St. Andrew Place, Santa Ana, CA 92705 USA Phone: +1 714 466 1000 – Fax: +1 714 466 5800 – Internet: www.powerwave.com This manual or parts of it may not be reproduced without the written permission of Powerwave Technologies. Infringements will be prosecuted. All rights reserved. Copyright © Powerwave Technologies, Inc., CA 92705 USA, 1994 – 2004. ii Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Preface Contents Abbreviations .................................................................................................................................. v 1. Safety ......................................................................................................................................... 1-1 Human Exposure of RF Radiation ..................................................................................... 1-3 Repeater Antennas ........................................................................................................ 1-3 Installation and Maintenance of Antenna Systems ....................................................... 1-3 Radiation Exposure ....................................................................................................... 1-4 Radiation Safety Distances ........................................................................................... 1-4 Static Electricity ................................................................................................................. 1-6 2. Introduction ............................................................................................................................... 2-1 Fiber Optics in General ...................................................................................................... 2-2 Fiber Optic Transmission Versus Electrical Transmission ........................................... 2-3 Duplex Transmission .................................................................................................... 2-4 System Building Blocks ..................................................................................................... 2-5 FON, Fiber Optic Node ................................................................................................. 2-6 FOU, Fiber Optic Unit .................................................................................................. 2-6 BMU, Base Station Master Unit ................................................................................... 2-7 RMU, Repeater Master Unit ......................................................................................... 2-7 FOR, Fiber Optic Repeater ........................................................................................... 2-7 OCM, Optical Converter Module ................................................................................. 2-8 RH, Remote Hub ........................................................................................................... 2-9 3. FON, Fiber Optic Node ............................................................................................................. 3-1 Functional Description ....................................................................................................... 3-1 Block Diagram .............................................................................................................. 3-2 R2R Communication .................................................................................................... 3-4 Gateway Node ............................................................................................................... 3-5 Alarm ............................................................................................................................ 3-5 Power ............................................................................................................................ 3-5 Backup Power ............................................................................................................... 3-5 Design ................................................................................................................................ 3-6 The FON Board ............................................................................................................. 3-6 Indicators ....................................................................................................................... 3-6 RF and Optical Ports ..................................................................................................... 3-8 Connection Ports ........................................................................................................... 3-9 Operational Control ............................................................................................................ 3-11 4. RF Over Fiber ........................................................................................................................... 4-1 The RF Modulated Signal Paths ........................................................................................ 4-2 Downlink RF Signal Path ............................................................................................. 4-3 Uplink RF Signal Path .................................................................................................. 4-8 FOU, Fiber Optic Unit .................................................................................................. 4-10 Noise, Intermodulation and Dynamic Signal Range ..................................................... 4-11 Simplex Transmission ........................................................................................................ 4-12 Duplex Transmission ......................................................................................................... 4-13 VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 iii Preface Fiber Optics Powerwave 5. IP Over Fiber ............................................................................................................................ 5-1 IP Network Terminology ................................................................................................... Requirements ..................................................................................................................... F-Net Characteristics ......................................................................................................... Node Units ......................................................................................................................... The FON Unit Net Interfaces ....................................................................................... Network Example .............................................................................................................. 5-2 5-3 5-4 5-5 5-6 5-7 6. Commissioning ......................................................................................................................... 6-1 Equipment Required .......................................................................................................... Commissioning the Fiber Optic System ............................................................................ Master Unit Downlink Path .......................................................................................... Slave Units ................................................................................................................... System Configuration Examples ....................................................................................... 6-1 6-2 6-2 6-3 6-6 7. Passive Devices ........................................................................................................................ 7-1 OSP, Optical Splitter ......................................................................................................... Graphic Symbol ............................................................................................................ Examples ...................................................................................................................... WDM, Wavelength Division Multiplexer ......................................................................... Graphic Symbol ............................................................................................................ Example ........................................................................................................................ Fiber Optic Cables ............................................................................................................. Powerwave Patch Cables .............................................................................................. Fiber Optic Connectors ...................................................................................................... Connector Types ........................................................................................................... Handling Connectors .................................................................................................... 7-2 7-3 7-3 7-4 7-5 7-5 7-6 7-8 7-9 7-10 7-11 8. Troubleshooting ........................................................................................................................ 8-1 Index ............................................................................................................................................... I-1 Questionnaire .............................................................................................................................. Q-1 iv Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Preface Abbreviations Abbreviations used in the document, in the software and in supported hardware: 3G AGC ALI ALR ALT AMPS AR BCCH BMU BA BS BSA BSC BSel BTS CDMA CH CHA CMB CSA CSel CU CW DAMPS DAS DC DCS DFB DIA DIF DL DNS DMB DPX EEPROM EGSM ETACS ETS F2F FCC FLI F-link F-net FON FOR FOT FOU GSM GPS HW ICMP IM IP LAN LED VM100 56/EN – User’s Manual Third Generation mobile system. Automatic Gain Control. Alarm Interface (board). Powerwave low power repeater (usually called Compact repeater). Powerwave low power train repeater. Advanced Mobile Phone Service. Powerwave repeater (usually called standard repeater). Broadcast Control Channel. Base station Master Unit. Booster Amplifier. Base Station. Band Selective Amplifier (board). Band Selective Compact repeater (board). Band Selective repeater. Base station Transceiver System. Code Division Multiple Access. Central Hub. Channel Amplifier (board). Combiner CDMA/WCDMA Segment Amplifier (board). Channel Selective repeater. Control Unit (board). Continuous Wave. Digital Advanced Mobile Phone Service. Distributed Antenna System. Directional Coupler. Digital Communication System (same as PCN). Distributed Feedback. Distribution (board). Diplex Filter. Downlink (signal direction from base station, via repeater, to mobile station). Domain Name Server. Digital Multimedia Broadcasting. Duplex filter. Electrical Erasable Programmable Read Only Memory. Extended Global System for Mobile communication. Extended Total Access Communication System. European Telecommunications Standards. Fiber to Fiber link (renamed to F-link/FLI). Federal Communications Commission. Fiber Link Interface. Fiber link. Fiber network. Fiber Optic Node. Fiber Optic Repeater. Fiber Optic Transceiver. Fiber Optic Unit. Global System for Mobile communication. Global Position System. Hardware Internet Control Message Protocol. Intermodulation. Internet Protocol. Local Area Network. Light Emitting Diode. Rev. P1A9-Draft 2004-11 Preface Fiber Optics LinDAS LNA MACID MRX MS MSC NAPT NMT NS OCM OM-Online OMS OMT16 OMT32 OSP PA PEP PCN PCS PPP PSM PSTN PSU PTFE R2R R2R net RAS RCC RCM RCU RF RH RIA RMS RMU RSSI RTC RX SLW SW TACS TDMA TX UDP UL UPS VAC VDC WAN WBA WCDMA WCS WDM WLI W-link W-net WRH vi Powerwave Light Indoor Distributed Antenna System. Low Noise Amplifier (unit). Physical address to RIA or CU board (comparable with Ethernet card MACID). Measurement Receiver (board). Mobile Station. Mobile Switching Center. Network Address and Port Translation. Nordic Mobile Telephone (system). Name Server. Optical Converter Module. Operation and Maintenance Online. Operation and Maintenance System. Operation and Maintenance Terminal (replaced with OMT32). Operation and Maintenance Terminal (replaced with OM-Online). Optical Splitter. Power Amplifier (board). Peak Envelope Power. Personal Communication Network (same as DCS). Personal Communication System. Point to Point Protocol. Power Supply Module. Public Switched Telephone Network. Power Supply Unit. Polytetrafluoro Ethylene (Teflon). Repeater to Repeater (Powerwave specific network). R2R network. Remote Access Service. Remote Communication Control (unit). RF Combiner Module. Remote Control Unit. Radio Frequency. Remote Hub. Repeater Interface Adapter (board). Root Mean Square. Repeater Master Unit. Received Signal Strength Indication. Real Time Clock. Receiver Sliding Window (Powerwave specific protocol). Software Total Access Communication System. Time Division Multiple Access. Transmitter User Datagram Protocol. Uplink (signal direction from mobile station via repeater to base station). Uninterruptible Power Supply. Voltage Alternating Current. Voltage Direct Current. Wide Area Network. Wideband Amplifier (board). Wideband Code Division Multiple Access. Wideband Coverage System. Wavelength Division Multiplexer. Wire Link Interface. Wire link. Wire network. Wideband Radio Head. Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 1. Safety In this chapter, the word ’repeater’ includes all Powerwave repeating units, such as repeaters, hubs and radio heads. It is necessary that any personnel involved in installation, operation or service of units included in an Powerwave repeater system understand and follow the below points. • The Powerwave repeaters are designed to receive and amplify signals from one or more base stations and retransmit the signals to one or more mobile stations. And, also to act the other way round, that is to receive signals from one or more mobile stations, amplify and retransmit the signals to the base stations. Powerwave repeater systems must be used exclusively for this purpose and nothing else. • Units supplied from the mains must be connected to grounded outlets and in conformity with the local prescriptions. • Power supply units supplied from the mains contain dangerous voltage that can cause electric shock. Disconnect the mains prior to any work in such a unit. Local regulations are to be followed when servicing such units. Authorized service personnel only are allowed to service units while the mains is connected. • All RF transmitting units, including repeaters, will generate radio signals and thereby give rise to electromagnetic fields that may be hazardous to the health of any person who is extensively exposed close to an antenna. See the Human Exposure of RF Radiation section on page 1-3. • Beryllium oxide Beryllium oxide (BeO) may be contained in power devices, for instance in dummy loads in directional couplers (DCC), in combiner units (CMB), and in attenuators on the FON board. Beryllium oxide is poisonous if present as dust or smoke that can be inhaled. Do not file, grind, machine, or treat these parts with acid. • Hydrogen fluoride Coaxial cables used in many Powerwave systems have the insulation made of PTFE, polytetrafluoro ethylene, that gives off small amounts of hydrogen fluoride when heated. Hydrogen fluoride is poisonous. Do not use heating tools when stripping off coaxial cable insulation. No particular measures are to be taken in case of fire because the emitted concentration of hydrogen fluoride is very low. VM100 56/EN – User’s Manual • A lithium battery is permanently mounted in repeater CU units, and in FON and OCM units. Due to the risk of explosion, this battery must only be removed from the board by an Powerwave authorized service technician. • NiCd batteries are mounted on the FON unit. These batteries contain environmental poisonous substances. If replaced, the old batteries should be taken care of as stated in the local prescriptions. Rev. P1A9-Draft 2004-11 1-1 Fiber Optics • Powerwave The FON unit contains a class IIIb laser transmitter that emits 2 – 5mW invisible laser radiation during operation. Avoid direct exposure from unconnected laser transmitter or fiber cord as follows: – Do not power up the FON unit if a fiber cable is not attached to the fiber output UL port, neither if a fiber cable is attached to the port but unattached in the other end. – Never look in the end of a fiber cable. The 1310nm and 1550nm laser light is not visible, so no signal identification can be made anyway. Use always an instrument, such as a power meter to detect signaling. – Never use any kind of magnifying devices that can focus the laser light to an unprotected eye. 1-2 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Human Exposure of RF Radiation This section contains a few words about repeater antennas and prescriptions for installaton and maintenance of antenna systems. Also, it describes how to calculate safety distances needed for RF radiation at different antenna power and frequencies. Repeater Antennas To be able to receive and transmit signals as described in the first bulleted paragraph on page 1-1, a repeater is connected to a donor antenna directed towards the base station, and a service antenna directed towards the coverage area. A fiber optic cable from the base station might, however, be substituted for the donor antenna. Installation and Maintenance of Antenna Systems Installation and maintenance of all repeater antenna systems must be performed with respect to the radiation exposure limits for public areas. The antenna radiation level is affected by the repeater output power, the antenna gain, and by transmission devices such as cables, connectors, splitters and feeders. Have also in mind that the system minimum coupling loss, typical between 25dB and 35dB, is determined by a standard with the purpose to protect base stations from noise and other performance dropping effects. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 1-3 Fiber Optics Powerwave Radiation Exposure WHO, World Health Organization, and ICNIRP, International Commission on NonIonising Radiation Protection, have determined recommendations for radiation exposure. ICNIRP recommends not to exceed the following radiation power for public exposure: Frequency 900MHz 1800MHz 2100MHz Radiation power 4,5W/m² 9,0W/m² 10,0W/m² For antennas larger than 20cm the maximum radiation power can be calculated by using the following formula: S = -------------------2 4uSur where S = Radiation power in W/m². P = Output power in W. r = Distance between antenna and human in meter. To tackle the worst case successfully, the calculation does not consider system power reducing actions, such as power control and DTX. Figure 1-1 shows the safety distance to an antenna due to the RF radiation. The distance is depending on the antenna output power and frequency, which is illustrated with two graphs in the figure. One of the graphs applies to 4.5W/m2 (900MHz) and the other to 9.0W/m2 (1800MHz) or 10.0W/m2 (2100MHz). The safety distance range in Figure 1-1 is 0 to 1.4 meter that covers an antenna power range of 10dBm to 50dBm (0.01W to 100W). Radiation Safety Distances This section illustrates the safety distances to the antennas for some typical repeater configurations. Outdoor GSM 900MHz Repeater output power Feeder loss Antenna gain EIRP +33dBm –5dB +17dBi +45dBm The safety distance can be read to 0.75 meter in Figure 1-1 as the maximum radiation power is 4.5W/m² for 900MHz. 1-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 100 50 9W/m2 (1800MHz) 10W/m2 (2100MHz) 31.6 4.5W/m2 (900MHz) 40 10.0 35 3.2 30 1.0 25 0.3 20 0.1 15 0.03 10 0.01 0.1 0.2 0.3 0.4 1.0 0.5 0.6 0.7 0.8 0.9 Safety distance to antenna in meter 1.1 1.2 1.3 Antenna output power in W Antenna output power in dBm 45 1.4 Figure 1-1. Safety distance to active antenna Indoor GSM 900MHz Repeater output power Feeder loss Antenna gain EIRP +22dBm –5dB +1dBi +18dBm The safety distance can be read to 0.035 meter for 4.5W/m² (900MHz). Outdoor UMTS Standard High Power Repeater output power Feeder loss Antenna gain EIRP +38dBm –5dB +17dBi +50dBm The safety distance can be read to 0.9 meter for 10W/m² (2100MHz). Indoor UMTS Repeater output power Feeder loss Antenna gain EIRP +24dBm –5dB +3dBi +22dBm The safety distance can be read to 0.035 meter for 10W/m² (2100MHz). VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 1-5 Fiber Optics Powerwave Static Electricity Static electricity means no risk of personal injury but it can severely damage essential parts of the equipment, if not handled carefully. Parts on the printed circuit boards as well as other parts in the equipment are sensitive to electrostatic discharge. Never touch the printed circuit boards or uninsulated conductor surfaces unless absolutely necessary. If you must handle the printed circuit boards or uninsulated conductor surfaces, use ESD protective equipment, or first touch the chassis with your hand and then do not move your feet on the floor. Never let your clothes touch printed circuit boards or uninsulated conductor surfaces. Always store printed circuit boards in ESD-safe bags. 1-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 2. Introduction The first official demonstration of the fiber optics technology took place at the British Royal Society in London, 1870. It was given by natural philosopher John Tyndall. He used a container with a spout and water. As the water poured through the spout, the light from the inside of the container followed the curved water path. Figure 2-1. John Tyndall’s first guided light transmission This demonstation was the first research into guided light transmission. Ten years later, in 1880, William Wheeling patented a method to transfer light in tubes, ’piping light’ through plumbing. However, this never took off because Edison invented the light bulb. Alexander Graham Bell was, about the same time, the first ever to arrange an optical amplitude modulated transmission over 200m. This was, however, achieved by emitting light beams in free space. Graham Bell’s idea was not to use wire for telephone communication. In the decade around 1950, the first practical all-glass fibers was developed which gave a success to the technology. It was Brian O’Brien at the American Optical Company and Narinder Kapany at the Imperial College of Science and Technology in London who was first to practically use an image-transmitting fiber-scope. Narinder Kapany was the man who coined the term ’fiber optics’ in 1956. Since that time, the laser and then the semiconductor laser have been very important inventions making the technology to grow increasingly and also become a fascinating and mysterious industry, where much of the technology has been isolated from outsiders. This manual is an attempt to open the curtain for a small area of this technology – fiber optic transmission between repeaters. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 2-1 Powerwave Fiber Optics Fiber Optics in General In the beginning, when fiber optics became in practical use, a ’first window’ with a wavelength of 850nm was used. It had a loss of approximately 3dB/km. As the technology developed, the ’second window’ at 1300nm became more attractive because of the lower loss, below 1dB/km. Today, the ’third window’ at 1550nm is the most attractive wavelength with a loss of 0.2dB/km for silica-based fibers. The ’second window’ at 1300nm can today, with silica-based fibers, achieve a loss of only 0.35dB/km. The following figure illustrates the three ’windows’ where the loss is low over the usable wavelength range. 10 First window Rayleigh scattering loss Second Third window window Fiber molecule absorption loss dB/km 5 Visible light 600 800 1000 1200 1400 1600 1800 2000nm Figure 2-2. The three wavelength windows Figure 2-2 illustrates the losses for the three wavelengt windows, with silica-based fibers. The large absorption peaks in the diagram are caused mainly by moisture in the fiber, and by scattering at shorter wavlengths. Figure 2-2 also shows the visible light wavelegth band, the loss curve caused by Rayleigh scattering at shorter wavelengths, and the loss curve caused by fiber molecule absorption at longer wavelengths. The wavelengts used by the FON boards in the repeaters are within the second window (1310nm) and the third window (1550nm). 2-2 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Fiber Optic Transmission Versus Electrical Transmission This section points out some differences between fiber optic transmission and electrical transmission via copper. The most signficant differences are loss, bandwidth, electromagnetic interference, security, signal quality, and weight. Low loss per km In general, optical transmission over fiber offers the lowest propagation loss but also more complexity. It also adds conversion loss for electrical-to-optical signal conversion, and conversion loss the other way round. This means that there is a break-even distance due to the propagation loss, where fiber optics starts to be more cost-effective. For repeater usage, the following suggestion can be applicable: For a distance shorter than 100m, use coaxial cable. For a distance between 100m and 1000m, let the situation determine. For a distance longer than 1000m, use fiber optics. High bandwidth High bandwidth is an advantage for fiber optics. It has a higher bandwidth than any other alternative (the immense potential bandwidth of 1tHz, that is 1012Hz). High bandwidth makes fiber optics become more and more common even on short distances as the Internet and other types of data communication demand high bandwidths. This makes fiber optic parts more and more common, which in the long run decreases the break-even distance for fiber optics usage. No electromagnetic (EM) interference As fiber consists of a non-conductive material, it is unaffected by all EM radiation. Security For the same reason that fiber is immune to EM radiation, it does not emit any EM radiation that can be detected. High signal quality Because of the immunity to EM radiation, high bandwidth, and low loss, the signal quality can be considerably better for fiber optic transmission than for electric transmission in copper. Low weight A copper cable usually has a weight of ten times that of a fiber cable. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 2-3 Fiber Optics Powerwave Duplex Transmission Full duplex transmission can be performed in a single fiber by transmitting one wavelength in one direction and another wavelength in the reverse direction. A wavelength division multiplexer (WDM) in each end separates the signals to an optical transmitter and an optical receiver. This is further described in Chapter 7, Passive Devices. 2-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics System Building Blocks This section contains short descriptions of the Powerwave fiber optic building blocks listed below. Building modules • FON, Fiber Optic Node, page 2-6. • FOU, Fiber Optic Unit, page 2-6. Repeater units VM100 56/EN – User’s Manual • BMU, Base Station Master Unit, page 2-7. • RMU, Repeater Master Unit, page 2-7. • FOR, Fiber Optic Repeater, page 2-7. • OCM, Optical Converter Module, page 2-8. • RH, Remote Hub, page 2-9. Rev. P1A9-Draft 2004-11 2-5 Powerwave Fiber Optics FON, Fiber Optic Node The FON unit is the heart of all Powerwave fiber optic repeater systems. The FON unit contains an optical transmitter and an optical receiver. No other Powerwave repeater building block has these facilities. P102 P115 P109 RX P103 P105 P111 P116 P108 P106 P104 P113 P114 Beryllium oxide hazard P110 P101 TX P130 P112 Figure 2-3. The FON unit This unit is normally part of the FOU, Fiber Optic Unit. The FON unit is detailed in Chapter 3, FON, Fiber Optic Node. FOU, Fiber Optic Unit The FOU, Fiber Optic Unit, is a complete unit for fiber optic interconnection of two or more repeaters. It is built up on a flanged plate and can be inserted in all types of LGP Allgon AR repeaters. In the simpliest configuration, it contains a FON board and a DPX filter. P102 RX P103 P115 P109 P105 P111 P116 P108 P106 P104 Beryllium oxide hazard P113 P114 P110 P101 TX P130 P112 Figure 2-4. The FOU unit Figure 2-4 shows an example of the FOU with a typical configuration. Both RF and optical devices, such as DPX filters, RF combiners, optical splitters and WDMs, can be configured on the FOU plate. The FON board is always included in the FOU. The FOU is also described in the FOU, Fiber Optic Unit section in Chapter 4. 2-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics BMU, Base Station Master Unit A BMU is an RF repeater type equipped with a FOU that gives the repeater ability to transmit and receive optical signals on the service side. The BMU has an RF port for BTS connection and up to four fiber optic ports that can be connected to FORs. ALLGON By configuring the FOU with WDMs and OSPs, up to approximately four FORs can be fed in parallel by a BMU via double or single fiber communication. Up to approximately eight FORs can be fed with a high cover and two FOUs. RF The BMU is described, with all included sub units, block diagram, and mechanical design, in the VD203 66/EN, AR Repeaters, User’s Manual. RMU, Repeater Master Unit An RMU is an RF repeater type equipped with an FOU that gives the repeater ability to transmit and receive optical signals on the service side. The RMU has an RF port for a donor antenna and up to four fiber optic ports that can be connected to FORs. ALLGON By configuring the FOU with WDMs and OSPs, up to four FORs can be fed in parallel by a BMU via double or single fiber communication. Up to eight FORs can be fed with a high cover and two FOUs. RF The RMU is described, with all included sub units, block diagram, and mechanical design, in the VD203 66/EN, AR Repeaters, User’s Manual. FOR, Fiber Optic Repeater A FOR is an RF repeater type equipped with an FOU that gives the repeater ability to transmit and receive optical signals on the donor side. The FOR has a fiber optic donor port and an RF port for a service antenna. ALLGON RF By configuring the FOU with a splitter, another FOR can be optically connected to the same RF system. The FOR can be connected to a BMU or RMU. The FOR is described, with all included sub units, block diagram, and mechanical design, in the VD203 66/EN, AR Repeaters, User’s Manual. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 2-7 Powerwave Fiber Optics OCM, Optical Converter Module The OCM is, principally, an indoor rack mounted BMU with several channels for different bands, systems, and operators. The front view of the OCM is shown in Figure 2-5. RF IN/OUT ANT STATUS LOCAL O&M OPTICAL IN/OUT A1 B1 C1 A2 B2 C2 MAINS REMOTE WLI A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4 A5 A6 A7 A8 B5 B6 B7 B8 C5 C6 C7 C8 WLI CAUTION ! MAX RF INPUT +36dBm OPTICAL CONVERTER MODULE Figure 2-5. OCM, Optical Converter Module The OCM can contain up to three FON boards, and a large number of splitter configurations. The OCM is designed to work with an RCM, RF Combiner Module, in a DAS concept, see Figure 2-6. RH RH BTS RF IN/OUT ANT STATUS LOCAL O&M OPTICAL IN/OUT A1 A2 B1 C1 B2 C2 MAINS REMOTE WLI A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4 A5 A6 A7 A8 B5 B6 B7 B8 C5 C6 C7 C8 WLI OCM CAUTION ! MAX RF INPUT +36dBm CH RF IN/OUT OPTICAL CONVERTER MODULE BTS RF IN/OUT A1 B1 C1 A1 A2 A3 A4 B1 B2 B3 B4 C1 C2 C3 C4 A2 B2 C2 A5 A6 A7 A8 B5 B6 B7 B8 C5 C6 C7 C8 RCM CAUTION ! MAX BTS RF INPUT +40dBm RF COMBINER MODULE Figure 2-6. The concept of DAS System, installation, and commissioning descriptions of the OCM are found in the VD205 03/EN, LinDAS, Installation Guide. 2-8 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics RH, Remote Hub The RH is, principially, a FOR unit in a compact cabinet. The RH unit has, however, no FOU but the FON board is mounted directly in the cabinet. The RH is used in DAS systems. The front view of the RH is shown in Figure 2-7. Figure 2-7. RH, Remote Hub Figure 2-8 shows a Remote Hub cabinet inside with fiber optic cables from the OCM. P102 P103 Beryllium oxide hazard P101 LO HI ANT FON RX TX P115 P109 P104 P106 P110 P130 P105 P111 P112 P108 P113 P114 PSM Fiber optic cables from OCM. Figure 2-8. Remote hub donor fiber connection Installation and commissioning descriptions of the RH are found in the VD205 03/EN, LinDAS, Installation Guide. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 2-9 Fiber Optics 2 - 10 Rev. P1A9-Draft 2004-11 Powerwave VM100 56/EN – User’s Manual Powerwave Fiber Optics 3. FON, Fiber Optic Node This chapter describes the functionality, the design, and the operational control of the FON unit. P102 RX P115 P109 P103 P105 P111 P116 P108 P106 P104 Beryllium oxide hazard P113 P114 P110 P101 TX P130 P112 Figure 3-1. The FON unit A description of RF transmission over fiber using the FON unit is found in Chapter 4, RF Over Fiber. A description of IP network using the FON unit is found in Chapter 5, IP Over Fiber. Functional Description The Fiber Optic Node, FON, is a bi-directional electrical/optical signal converter and a node in either a wire network or a fiber network. It has also functionality for: – Electrical and optical signal supervision. – Internal and external alarm handling. – RS232 interface for local PC control via an O&M software (OM-Online). – Remote control via an O&M software (OM-Online or OMS). – Interface for RCC. – Interface for WLI, wire network. – Interface for FLI, fiber optic network. – Battery backup with charger. The FON unit can be installed in all Powerwave repeaters, remote hubs, and radio heads. This section contains a description of the FON unit, including block diagram, RF paths, IP path, R2R communication, FON as gateway node, alarm handling, power, and backup power. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-1 Powerwave Fiber Optics Block Diagram RF Path 1 RF IN P101 16dB, 8W FO TX 0 – 20dB Control Unit IP RF Path 2 RF OUT P102 16dB 0 – 20dB FO RX 16dB TEST P103 –15dB Figure 3-2. FON block diagram Figure 3-2 shows a block diagram of the FON unit. The downlink and uplink RF signal paths are described below. The control unit block contains circuitry and software for control of the RF paths, local and remote communication with O&M software, protocols for IP and R2R networks, internal and external alarm handling, power supervision, etc. The control unit has a number of input and output ports not shown in the block diagram. These ports are described in the Connection Ports section on page 3-9. RF Path 1 P102 The RF IN port (P101) is usually connected to BTS/DL in a BMU (Base station Master Unit), or to the UL amplifier in a FOR (Fiber Optic Repeater). The input frequency is 800 – 2200MHz and the input power 10 – 36dBm. P103 Beryllium oxide hazard P101 The first attenuator is a 16dB, 8W power device that is a security attenuator for the FON unit. It consists of two attenuators located under the shield, see the figure. There is a FON type without these input attenuators intended for specific configurations (described in the Uplink RF Signal Path section in Chapter 4). After the attenuator there is a software adjustable 0 – 20dB attenuator, manually set by the operator via O&M software. This attenuator is correctly set when the input power to the optical transmitter is 0dBm (examples are found in Chapter 6, Commissioning). The optical transmitter converts the electrical RF modulated signal to a 1310 or 1550nm optical RF modulated signal and injects it into a fiber for transmission to one or more fiber optic receivers. The output signal power is 2 – 5dBm, or 0.5 – 2dBm at low power (NF: 30 – 35dB and IP3: 30 – 35dBm). The IP3 is: 3-2 68dBm for channel selective repeater with 2 channels. 65dBm for channel selective repeater with 4 channels. 54dBm for band selective repeater. Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics RF Path 2 An optical 1310 or 1550nm input signal is received by an optical receiver. The power range for this input is between –15dBm and 1dBm optical power. To avoid receiver saturation, it should be less than 1dBm. After converting the optical RF modulated signal to an electrical RF modulated signal, it is amplified in two 16dB amplifier stages with a noise figure of 4dB each. Between the two 16dB amplifiers there is a software adjustable 0 – 20dB attenuator, manually set by the operator via O&M software. This attenuator is differently set depending on the FON usage. • If the FON unit is part of a BMU, then it is adjusted to an uplink gain that is dependent on the ratio of the BTS and the repeater coverage areas. • If the FON unit is part of a FOR, then it should be adjusted to match the repeater input amplifier power range. Examples of this are found in Chapter 6, Commissioning. The RF OUT port (P102) is usually connected to BTS/UL in a BMU, or to the DL amplifier in a FOR. The output power can be between 0dBm and 20dBm with a minimum noise (above the thermal noise) of 22dB. There is also an RF test output (P103) with an output level of 15dB below the RF OUT level. This output is intended for signal measurement without disconnecting the RF cable. IP Path The IP communication circuitry is located in the control unit. The subcarrier from the control unit is fed, via a filter, to the RF path before the optical transmitter, see Figure 3-2. In the connection point, the subcarrier is added to the RF signal. In the following optical transmitter, the RF signal with the added subcarrier is converted to an optical signal and transmitted to the connected optical receiver or receivers. A received optical RF signal with an added subcarrier is converted to an electrical signal in the optical receiver. After the first amplifier, the subcarrier passes a filter and is then fed to the IP circuitry input in the control unit. The subcarrier signal takes no power from the optical RF transmission. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-3 Powerwave Fiber Optics R2R Communication This section describes how to use the FON unit in R2R networks. The R2R network itself, its configuration, and R2R statistics are further described in the VM100 01/EN, OM-Online, User’s Manual. The R2R (Repeater to Repeater) network is an old Powerwave specific WLI network with SLW protocol and wire interconnection (W-net). WLI stands for Wire Link Interface, W-net for Wire network. SLW (Sliding Window) is an Powerwave specific protocol developed for the R2R network. The IP network can be used in fiber networks as well as in wire networks. However, the IP wire network and the R2R wire network have different protocols and can, for this reason, not communicate with each other. R2R network characteristics FON FON FON The R2R uses a twisted pair or RS-485 bi-directional bus with a master unit and slave units. The bus is connected to the FON boards via the WLI ports, see the Connection Ports section on page 3-10. An example of an R2R network with four FON nodes is shown in Figure 3-3. FON FON FON FON RCC PSTN RCC PSTN Figure 3-3. R2R network with four FON nodes Gateway The R2R network can contain maximum 12 nodes. One or several of these nodes can be gateway nodes, that is to be able to communicate remotely with an O&M software via modem. A description of the FON unit as gateway is found in the Gateway Node section on page 3-5. The R2R network in Figure 3-3 contains two gateway nodes (connected to the PSTN). Control station All nodes in an R2R network can, and should, be configured with Control Station Capability enabled, which means that they can be the master unit if the current master unit ceases to work. 3-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Gateway Node A FON unit can be used as a network gateway node for IP networks as well as for R2R networks by being connected to an RCC (Remote Communication Control) unit, see Figure 3-3. The RCC unit is connected to the FON board via the RCC port, see the Connection Ports section on page 3-10. Both the FON unit and the RCC unit can be installed in all Powerwave repeaters and remote hubs. The gateway node in various repeater types is further detailed in the VM100 01/EN, OM-Online, User’s Manual. Alarm The FON unit has the same alarm and event handling as the Powerwave repeaters and remote hubs. Consequently, the entire Alarms and Events chapter in the VM100 01/EN, OM-Online, User’s Manual is applicable also for the FON unit. This includes also the four external alarms that are connected to the FON board via the Alarm port, see the Connection Ports section on page 3-9. Power The FON unit requires 6.0 –8.0V power supply. All Powerwave repeaters and remote hubs have a 7V DC power supply that is used for this purpose. This power is connected to the FON board via the Power port, see the Connection Ports section on page 3-9. Backup Power If a power failure occurs, a backup battery has capacity to supply the FON control unit with the network for up to30 minutes at room temperature. This time is intended for alarm transmission. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-5 Powerwave Fiber Optics Design This section describes the FON board layout, including indicators, coaxial ports, optical ports, connectors, and jumpers. The FON Board The FON board is built up on a printed circuit board that also contains the battery backup. The FON board is shown in Figure 3-4. P102 P115 P109 RX P103 P105 P111 P116 P108 P106 P113 P114 P104 Beryllium oxide hazard P110 P101 TX P130 P112 Figure 3-4. The FON board Indicators FLI RX P105 P111 P116 P108 P115 P109 P106 P104 P113 P114 TX P130 FAULT OPER P110 BOOT POWER DATA WLI/R2R P112 CHARGE BATT Figure 3-5. FON indicators and ports The FON board contains the below described LED indicators. FLI (or F2F) fiber network Green LED that indicates, with a flashing light, that the unit receives data over the sub carrier. A steady light indicates that the unit does not currently receive any data, or there is no other node in the network. 3-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics OPER Green LED that lights up approximately 15 seconds after the mains is switched on. It shows, with a steady light, that the unit is ready for operation. FAULT Red LED that flashes 15 – 20 seconds after the mains is switched on. Then, it flashes for less serious alarms (Error) and is lit with a steady light for fatal alarms (Critical). POWER Yellow LED that indicates present power. It is lit with a steady light after the mains is switched on. BOOT Red LED that is lit with a steady light when the control unit boots, that is for 10 – 15 seconds after the mains is switched on. Then, it flashes for the next 5 – 10 seconds. After that, if no error is detected, the LED is off. If an error occur, then the LED is lit. WLI (or R2R) wire network Green LED that indicates, with a flashing light, that the unit is receiving data over the sub carrier. A steady light indicates one of the following three states: The unit is currently not receiving any data. The unit is currently not a Control station. Or, there is no other node in the network. DATA Blue LED that indicates data transmission in the W-net. BATT Green LED that indicates, with a steady light, that the battery pack currently is used as power source. CHARGE Yellow LED that indicates battery charge with a steady light. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-7 Powerwave Fiber Optics RF and Optical Ports P102 RX P103 Beryllium oxide hazard P101 TX Figure 3-6. RF and optical ports The FON board has three coaxial ports and two optical ports for the downlink and uplink RF signal. The following table shows the port numbers, connector types, and the port usages. Port Type P101 P102 P103 RX TX SMA SMA SMA DIN/APC DIN/APC Description Electrical RF input port (to the optical TX port). Electrical RF output port (from the optical RX port). Electrical RF output port (15dB below the P102 port). Optical input port (to the P102 and P103 RF ports). Optical output port (from the P101 RF port). Caution There are two power attenuators at the P101 port (under the shield) on the FON board, see Figure 3-6. These may contain beryllium oxide (BeO), which is poisonous. See Chapter 1, Safety. Beryllium oxide 3-8 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Connection Ports Except for the downlink and uplink RF ports, the FON board contains the below described connection ports. P104 – Debug This port is used only for development and debugging. P105 – Front LED indicators P105 is a 4 pole male connector used for the yellow and red LED indicators located on the front cabinet door. P106 – PC P106 is a 9 pole D-sub female RS-232 port used for local PC communication. This port has the following pinning: Pin 1 Not used (GND). Pin 2 Data from FON to PC. Pin 3 Data from PC to FON. Pin 4 DTR from PC to FON. Pin 5 GND Pin 6 DSR from FON to PC. Pin 7 RTS from PC to FON. Pin 8 CTS from FON to PC. P108 and P116 – Power Power and alarm ports for the FON board. P108 and P116 are 6 pole male connectors used for providing the FON board with power. P108 and P116 are connected in parallel for cascade connection or single use. These ports have the following pinning: Pin 1 +7V in. Pin 2 +7V backup out (controlled by P114). Pin 3 Alarm output. Pin 4 GND Pin 5 Not used. Pin 6 GND. P109 – Alarm P109 is a 7 pole male alarm connector used for external alarm sensors. This port has the following pinning: Pin 1 AIC Ground. Pin 2 AIC Ground. Pin 3 AI1 External alarm input 1 – EAL1. Pin 4 AI2 External alarm input 2 – EAL2. Pin 5 AI3 External alarm input 3 – EAL3. Pin 6 AI4 External alarm input 4 – EAL4. Pin 7 Not used. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3-9 Powerwave Fiber Optics P110 – W-link jumper This jumper is used to terminate units in a W-link. It has to be set in the parking state for all units except for the first and last units in a W-link. Parking state is shown in the figure (the pins farest away from the battery pack interconnected). The opposite state terminates the W-link. P111, P112 – WLI ports P111 and P112 are 5 pole male connectors used for interconnecting nodes in WLI-nets (IP or R2R networks). P111 and P112 are identical and connected in parallel. One of the connectors are intended to be used from the previous node, and the other connector to the next node in the network. Either of P111 or P112 can be used for the first and the last unit in the net chain. P113 – Batteries P113 is a 2 pole male connector used for the on-board backup batteries. P114 – Backup power output This jumper sets the backup power output state. The OFF state is shown in the figure (the pins closest to the battery pack interconnected). This jumper has to be in the OFF state when used in an OCM unit. Otherwise, it shall be in the ON state (opposite to the figure). P115 – Future port P115 is a 3 pole male connector intended for future use (not used for the time being). P130 – RCC port P130 is a 34 pole 2 line male connector used for connecting an RCC, Remote Communication Control unit. The P130 connector contains both the modem connection and RCC power supply. 33 3 - 10 34 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Operational Control The FON unit can be locally or remotely controlled via an O&M software (remote control via modem). All descriptions in this document refer to the OM-Online O&M software. Parameter names may differ somewhat when working with OMS, but the functionality of the parameters are the same. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 3 - 11 Fiber Optics 3 - 12 Rev. P1A9-Draft 2004-11 Powerwave VM100 56/EN – User’s Manual Powerwave Fiber Optics 4. RF Over Fiber This chapter describes the downlink RF modulated signal from the BTS to the repeater antenna, and the other way around from the repeater antenna to the BTS. The description is focused on the optical part of the RF transmission. The chapter is divided into the following main parts: • • • • • • • VM100 56/EN – User’s Manual RF signal path overview for downlink and uplink signals, page 4-2. Detailed description of the downlink signal path, page 4-3. Detailed description of the uplink signal path, page 4-8. Brief description of the FOU, Fiber Optic Unit, page 4-10. Brief descriptions of noise, intermodulation, and dynamic signal range, page 4-11. Some examples of simplex transmission, page 4-12. Some examples of full-duplex transmission, page 4-13. Rev. P1A9-Draft 2004-11 4-1 Powerwave Fiber Optics The RF Modulated Signal Paths Figure 4-1 illustrates the downlink RF modulated signal path from the BTS via a BMU, optical fiber, and a FOR to the repeater antenna. And also the uplink path from the repeater antenna back to the BTS. DL DC DPX TX FOR RX FON FON RX TX DPX BMU UL BTS Figure 4-1. Downlink and uplink RF modulated signal paths As the signal paths mainly are handled by the FON units, the signal description for this unit, found in the RF Path 1 and RF Path 2 sections in Chapter 3, is applicable to the downlink and uplink RF modulated signal paths. The amplifiers and duplex filter (DPX) in the FOR are, however, not included in the FON description, but are found in the repeater manual (VD203 66/EN, AR Repeaters, User’s Manual). The signal paths are, however, also described below, but more in terms of radio frequency signals in the entire chain, from the BTS to the repeater antenna, and the other way around. 4-2 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Downlink RF Signal Path The downlink RF modulated signal path, from the BTS to the repeater antenna, is shown in Figure 4-2. The item numbers in the figure are described below. DL DC DPX TX FOR RX FON FON DPX BMU 9 10 11 12 Figure 4-2. Downlink RF transmission path 1. DC coupler BMU 20dB DC DL 40dBm BTS NF 5dB The DC coupler on the BTS antenna path picks up the BTS downlink signal with a fixed coupling loss of 20dB. The left figure shows the DC coupler connected to the BTS antenna path and the BTS downlink amplifier with a typical noise figure of 5dB. The values in the figure are typical values that can vary from one system to another. 2. DPX duplex filter DPX A Powerwave duplex filter separates the downlink and uplink signal frequencies between the BTS antenna path and the separate input/output RF ports of the FON unit. The Powerwave DPX filter has a typical loss of 1dB. 3. Power attenuator An input 16dB/8W power attenuator is a security attenuator for the FON unit. 16dB, 8W 4. Software adjustable attenuator The software adjustable 0 – 20dB attenuator is set manually via an O&M software. This is described in the FON section of the VM100 01/EN, OM-Online, User’s Manual. 0 – 20dB The attenuator should be set to a calculated value that attenuates the signal power to 0dBm to the following optical transmitter. Example: Presume the typical values in the figures above are used, that is: – – – – BTS output = 40dBm DC coupler loss = 20dB DPX filter loss = 1dB power attenuator = 16dB Set the attenuator to 3dB (40dBm – 20dB – 1dB – 16dB = 3dB). VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 4-3 Powerwave Fiber Optics 5. Optical transmitter The optical transmitter converts the electrical RF modulated signal to a 1310 or 1550nm optical RF modulated signal. The transmitter ends with an optical female connector. TX The transmitter has a laser diode for transmitting the optical signal, and a back-facet monitor photodiode that provides a real-time monitoring of the optical output. 10 25°C Po (mW) 0°C 50°C 20 40 60 IF (mA) 80 100 The back-facet monitor photodiode is used to control the laser treshold current that is temperature dependent. See the treshold current bends of the optical power output curves for some different temperatures in the left figure. The values shown in the diagram are typical values that can vary for diffierent devices. By using the back-facet monitor photodiode, the optical transmitter is compensated for different operating temperatures and a temperature non-dependent electrical-to-optical curve can be used, see Figure 4-3. PO PO-RF IBIAS IRF Figure 4-3. Electircal to optical signal conversion The RF modulated optical output signal PO-RF has the same shape as the RF modulated electrical input signal IRF, see Figure 4-3. The IBIAS current is set to keep the dynamic 'IRF current range within the straight part of the curve, provided the input power is kept on about 0dBm (or lower). If the input power is much higher, then the PO-RF will be distored. The output signal can be the default power range or be set to a low power range via an O&M software. Default power range means 3.5 – 5dBm, low power range 0.5 – 2dBm. The noise figure for the optical transmitter is 30 – 35dB. The IP3 level is 30 – 35dBm. 4-4 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 6. Optical transmission In the example shown in Figure 4-2, the optical downlink transmission (between the optical transmitter and the optical receiver) is built-up with two optical connectors and one single-mode fiber. The optical connectors are of DIN/APC type. The coupling loss (gap and misalignment losses) for this connector type is approximately 0.5dB. The single-mode fiber loss is approximately 0.35dB/km for 1310nm and 0.20dB/km for 1550nm. The maximum fiber attenuation should not exceed 15dB. Example: At a distance of three kilometers, the optical transmission loss for a 1310nm signal is approximately 2dB (0.5dB + 3x0.35dB + 0.5dB), and for a 1550nm signal approximately 1.6dB (0.5dB + 3x0.20dB + 0.5dB). The optical transmission loss will increase for devices used to split the signal path to more than one receiver or to use the same fiber for both transmission directions. This is further described in the Simplex Transmission section on page 4-12, and in the Duplex Transmission section on page 4-13. Note that all optical losses, except for FOT/FOT and FON/FON conversion losses, are to be multiplied by two when converting to electrical RF losses. The reason why the optical loss has to be multiplied by two (in dB) is that the light detector in the optical receiver has a square shaped input area and thus extracts the square root of the input power. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 4-5 Powerwave Fiber Optics 7. Optical receiver The optical receiver performs the opposite function to the optical transmitter. It contains a light detector, that is a semiconductor photodiode that produces current in response to incident 1310 or 1550nm light. RX The conversion from an optical signal to an electrical RF signal is shown in Figure 4-4. PO PO-RF IRF Figure 4-4. Optical receiver light detector The optical input power to the light detector has to be between –15dBm and 1dBm. To avoid detector saturation that will result in signal distortion, it should be less than 1dBm. The optical output power is independent of the TX attenuation. The light detector adds very low amounts of shot noise and thermal noise. 8. Amplifier 16dB The converted electrical RF modulated signal is amplified in a 16dB amplifier with a noise figure of 4dB. 9. Software adjustable attenuator The software adjustable 0 – 20dB attenuator is set manually via an O&M software. This is described in the FON section of the VM100 01/EN, OM-Online, User’s Manual. 0 – 20dB Setting, see the following amplifier. 4-6 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics 10. Amplifier 16dB The RF modulated signal is finally amplified in the last FON stage, a 16dB amplifier with a noise figure of 4dB. The output signal minimum noise (above the thermal noise) is 22dB. The output power is set with the previous adjustable attenuator to match the repeater amplifier input level (maximum 13dBm). To achieve maximum output power from the repeater, the input signal level to the repeater has to be correct with respect to the gain. The signal level is adjusted with the FON adjustable attenuator. 11. Repeater amplifier The repeater amplifier consists of a low noise amplifier, LNA, a repeater amplifer stage, and a power amplifier. These stages are described in the VD203 66/EN, AR Repeaters, User’s Manual. DPX 12. DPX duplex filter VM100 56/EN – User’s Manual Separates the downlink and uplink signal frequencies between the repeater service antenna and the separate downlink/uplink FOR amplifiers. The DPX filter is described in the VD203 66/EN, AR Repeaters, User’s Manual. Rev. P1A9-Draft 2004-11 4-7 Powerwave Fiber Optics Uplink RF Signal Path The uplink RF modulated signal path, from the repeater service antenna to the BTS, is shown in Figure 4-5. The item numbers in the figure are described below. Item numbers are omitted for those items that have the same function and settings as in the downlink path. BMU FON FON RX DC DPX DPX FOR TX UL Figure 4-5. Uplink RF transmission path 1. Repeater amplifier The repeater amplifier is the same as the downlink amplifier, but in this case the output power should be adjusted to match the FON input power range, 10 – 36dBm. 2. Power attenuator The input 16dB/8W power attenuator is the same as the downlink amplifier, but in this case an alternative configuration can be used. DPX 16dB, 8W In the alternative configuration a FON unit without this power attenuator is used. In this case a lower output power from the FOR unit is fed directly to the following adjustable attenuator. The advantage of this configuration is less signal noise. 3. Software adjustable attenuator The software adjustable 0 – 20dB attenuator is set manually via an O&M software. This is described in the FON section of the VM100 01/EN, OM-Online, User’s Manual. 0 – 20dB DPX If the BTS has a larger coverage area than the repeater, then the attenuator is usually adjusted to a total uplink gain to the BTS of –10dB (shown in the figure). DC BMU –10dB BTS 4-8 FON If the coverage area is the same for the BTS and the repeater, then the BTS antenna input sensitivity with connected repeater should be the same as the sensitivity at the repeater antenna input. The total uplink gain can, however, not be set only on the software adjustable attenuator but has to be balanced on the three uplink set points highlighted in Figure 4-6 (see the next section). Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Setting the total uplink gain The three uplink set points, highlighted in Figure 4-6, have to be balanced to a total uplink gain appropriate to the ratio of the coverage areas for the BTS and the repeater. DC FOR FON FON RX TX DPX DPX BMU UL –10dB Figure 4-6. Total uplink gain setting points Coupling factors and power losses in the entire uplink chain, including the optic fiber, have also to be considered when setting the total uplink gain. A power calculator should be used when determining the uplink settings. Some examples with various settings are found in Chapter 6, Commissioning. VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 4-9 Powerwave Fiber Optics FOU, Fiber Optic Unit The FOU, Fiber Optic Unit, is a complete unit for fiber optic interconnection of two or more repeaters. It is built up on a flanged plate and can be inserted in all types of LGP Allgon AR repeaters. In the simpliest configuration, it contains a FON board and a DPX filter. Figure 4-7 shows a simple configured FOU, Fiber Optic Unit. FOU DPX RX FON TX Figure 4-7. The FOU, Fiber Optic Unit An FOU inserted in the BMU and in the FOR is shown in Figure 4-8. BMU FOU FOR FOU FON FON TX RX DPX DPX DC TX DPX RX BTS Figure 4-8. FOU inserted in the BMU and FOR The FOU can also be configured with optical splitters for more than one FOR in the optical network, and with WDMs for optical duplex transmission. 4 - 10 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Noise, Intermodulation and Dynamic Signal Range This section contains brief descriptions of noise, intermodulation, and dynamic signal range. Noise and intermodulation Figure 4-9 shows noise and intermodulation values for the optical transmission. Conversion loss 25dB TX FON Gain 30dB RX LFO NF = 30 – 35dB IP3 = 30 – 35dBm NFOUT FON NF = 3 – 4dB Figure 4-9. Noise and intermodulation If the fiber loss, LFO, is lower than 5dB, the output noise figure, NFOUT, is determined by the optical transmitter (’1’ in Figure 4-9). If the fiber loss, LFO, is higher than 5dB, the output noise figure, NFOUT, is determined by the receiver amplifier (2). Intermodulation and IP3 The third order of intermodulation is illustrated on a frequency axis in the figure. f1 f2 2f2–f1 DPX 2f1–f2 The formula for it reads: IM3 = 3P0 – 2IP3 dB where: IM3 = Intermodulation level. P0 = Carrier power. IP3 = The IP3 point of the amplifier. The IP3 values from the various types of repeater amplifiers are: BSA 54dBm CHA 68dBm for 2 channels, 65dBm for 4 channels. ALR 48dBm (compact repeater and RH) WRH 35dBm Dynamic signal range VM100 56/EN – User’s Manual The dynamic range for the RF signal is determined by the noise level and the IM requirements. The dynamic range is represented by a vertical arrow in the figure, where: P = Power S = Signal level. N = Noise floor + intermodulation. Rev. P1A9-Draft 2004-11 4 - 11 Powerwave Fiber Optics Simplex Transmission This section contains two examples of simplex transmission over fiber. RMU FOR BTS DL = 1310nm UL = 1310nm DL UL Figure 4-10. Simplex transmission between an RMU and a FOR unit The first example, shown in Figure 4-10, illustrates a simple configuration. This configuration is described in the previous sections in this chapter, but in this case an RMU is used for radio transmission with the BTS. The downlink and uplink wavelength is 1310nm. FOR BMU FOR FOR FOR BTS UL DL DL = 1310nm UL = 1310nm 50 50 50 50 UL UL UL 50 50 50 50 50 50 50 50 Figure 4-11. Simplex transmission between a BMU and four FOR units The second example, shown in Figure 4-11, illustrates a BMU and four FOR units connected via optical splitters in a star configuration. Downlink and uplink wavelength is 1310nm. The optical power loss for an optical 50/50 splitter is 3dB. Additional connectors add a loss of 0.5dB each. Due to the power sharing, up to approximately four slave nodes (FOR) can be connected to a master FON unit (BMU). For additional slave nodes, another FON unit has to be inserted in the BMU. The optical splitters are usually included in the FOU located in the BMU. Figure 4-11 shows, schematically, these parts outside the BMU cabinet. 4 - 12 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual Powerwave Fiber Optics Duplex Transmission This section contains two examples of full-duplex transmission over fiber. RMU FOR BTS DL DL = 1550nm UL = 1310nm UL DX O DX O Figure 4-12. Duplex transmission between an RMU and a FOR unit The first example, shown in Figure 4-12, illustrates the same repeater configuration as in the previous section, but now with full-duplex over one fiber achieved by using an optical WDM (DX O) in each repeater. The downlink wavelength is 1550nm, the uplink wavelength is 1310nm. The power loss for an optical WDM is 1dB. Additional connectors add the loss by 0.5dB each. The WDMs are included in the FOUs. BMU FOR FOR FOR BTS UL 1310nm UL 1308nm DL 1550nm DX O DX O DX O 30 70 50 50 UL 1312nm DX O Figure 4-13. Duplex transmission between a BMU and three FOR units The second example, shown in Figure 4-13, illustrates a BMU and three FOR units interconnected via optical splitters in a chain configuration. Full-duplex over one fiber is achieved by using an optical WDM (DX O) in each repeater node. The downlink wavelength is 1550nm, the uplink wavelengths are 1308nm, 1310nm, and 1312nm from the three slave nodes (FOR). VM100 56/EN – User’s Manual Rev. P1A9-Draft 2004-11 4 - 13 Fiber Optics Powerwave The optical power loss for an optical 30/70 percent splitter is 5.2dB/1.5dB, for a 50/50 percent splitter 3dB. The power loss for an optical WDM is 1dB. Additional connectors add the loss by 0.5dB each. Due to the power sharing, up to approximately four slave nodes (FOR) can be connected to a master FON unit (BMU). For additional slave nodes, another FON unit has to be inserted in the BMU. The optical WDMs and splitters are usually included in the FOU located in the BMU. Figure 4-13 shows, schematically, these parts outside the BMU cabinet. 4 - 14 Rev. P1A9-Draft 2004-11 VM100 56/EN – User’s Manual
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : No XMP Toolkit : 3.1-701 Modify Date : 2006:09:07 14:47:37-07:00 Create Date : 2006:09:07 14:46:40-07:00 Metadata Date : 2006:09:07 14:47:37-07:00 Creator Tool : PDFCreator Version 0.8.0 Format : application/pdf Title : RH300000_100_A Creator : syashg Document ID : uuid:4bad8fc3-916e-488f-a6ef-46ffde583ba9 Instance ID : uuid:ca5c0b13-0bcc-4b0c-8965-d2b1d0766787 Producer : AFPL Ghostscript 8.14 Has XFA : No Page Count : 50 Author : syashgEXIF Metadata provided by EXIF.tools