Powerwave Technologies 5JS0094 Wideband Radio Head User Manual 044 05251 WRH
Powerwave Technologies Inc Wideband Radio Head 044 05251 WRH
Users Manual
Wideband Radio Head (WRH) Installation and Service Manual 044-05251 Rev A March 2007 © 2007 Powerwave Technologies Incorporated. All rights reserved. Powerwave Technologies and the Powerwave logo are registered trademarks. Powerwave Technologies Inc. reserves the right to make changes to the documentation and equipment, including but not limited to component substitution and circuitry changes. Changes that impact this document may subsequently be incorporated in a later revision of this document. This Powerwave product is designed to operate within the Normal Operating (typical operating) ranges or conditions specified in this document. Operation of this equipment beyond the specified ranges in this document may cause (1) spurious emissions that violate regulatory requirements; (2) the equipment to be automatically removed from service when maximum thresholds are exceeded; or (3) the equipment to not perform in accordance with its specifications. It is the Operator's responsibility to ensure this equipment is properly installed and operated within Powerwave operating specifications to obtain proper performance from the equipment and to comply with regulatory requirements. The rated output power of a standard WRH is for single carrier operation; for a WRH-V it is for multiple carriers. As long as the composite power does not exceed the rated power (20W for North America), derating is not required for mutiple carriers. For situations above that, the rating would have to be reduced by 3.5 dB, especially where the output signal is re-radiated and can cause interference to adjacent band users. This power reduction is to be by means of input power or gain reduction and not by an attenuator at the output of the device. Input power is rated at 115/230VAC, 50/60Hz, and should be protected with a 20 A breaker. Power strips should, at a minimum, conform to this requirement to prevent equipment damage and possible overload. Federal Communications Commission (FCC) This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to part 15 of the FCC Rules. Changes or modifications not expressly approved by Powerwave Technologies, Inc. for compliance could void the user’s authority to operate this equipment. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense. Industry Canadian Requirement All Powerwave apparatus introduced on the Canadian market meet all requirements of the Canadian Interference-Causing Equipment Regulations. The -20dB bandwidth at 1900 MHz band is 80 MHz. The -20dB bandwidth at the 850 MHz is 34 MHz. Powerwave Technologies Inc., 1801 East St. Andrew Place, CA 92705 Santa Ana, USA. Phone +1 714 466 1000 – Fax +1 714 466 5800 – Internet www.powerwave.com Wideband Radio Head Revision Record Revision Record Revision Letter Date of Change Reason for Change 3A August 2005 Original VD203 66 March 2007 Document number changed to 044-05251 and manual updated 044-05251 Rev A This Page Intentionally Left Blank ii 044-05251 Rev A Table of Contents Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . v Chapter 1 - Product Description Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Scope of Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1 Human Exposure of RF Radiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Installation and Maintenance of Antenna Systems. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Radiation Exposure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Electrostatic Discharge (ESD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-2 Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 WRH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 WRH-V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 Chassis Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Sub Unit Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Wideband Amplifier PCBA (WBA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Power Amplifier PCBA (PA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Multi-Carrier Power Amplifier PCBA (MCPA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Booster Amplifier PCBA (BA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Control Unit PCBA (CU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-4 Distribution PCBA (DIA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Low Noise Amplifier (LNA) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Duplex Filter (DPX). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 Fiber Optic Unit (FOU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 Fiber Optic Node (FON) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 Power Supply Unit (PSU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 Remote Control Unit (RCU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI) . . . . . . . . . . . . . . . . . . .1-6 Sub Unit Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7 WRH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7 WRH-V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8 Fiber Optic Distribution Networks . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9 Multi-Operator Configurations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9 Chapter 2 - Controls, Indicators and Connectors Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 Front Cover Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 Cabinet Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 PCBA Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 CU PCBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 FON PCBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 WRH-V PCBA Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 WRH PCBA Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 DIA PCBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 BA PCBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6 DPX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6 LNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6 FON . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6 PSU . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-7 Software and Hardware Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9 044-05251 Rev A Table of Contents Wideband Radio Head Chapter 3 - Installation Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 Site Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 WRH Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-1 Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 Main Power and Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 Fiber Optic and RF Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 WRH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 WRH-V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6 Optional Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6 Alarms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6 External Alarm. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6 Door Open Alarm . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6 Fiber Link Interface (FLI). . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7 Main Power Breakdown Relay . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7 21-60 Volt DC PSU Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8 Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9 Initial Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10 Chapter 4 - Maintenance Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 Clearing Alarm Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 Field Replaceable Units. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 FON. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 PSU. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 WRH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 Return For Service Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 Obtaining an RMA. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 Repackaging for Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 Remote Control Unit (RCU) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 RCU for Radio Communication. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-8 RCU for Telephone Line Communication . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-8 Chapter 5 - Specifications Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 Appendix A - Block Diagrams Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Standard WRH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . WRH-V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Non-Diversity. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diversity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ii A-1 A-1 A-2 A-2 A-3 044-05251 Rev A Wideband Radio Head List of Figures List of Figures 1-1 Powerwave Wideband Radio Head (WRH) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-3 1-2 CU PCBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 1-3 DIA PCBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 1-4 LNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-5 1-5 FOU in WRH-V . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-6 1-6 Standard WRH Sub Unit Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-7 1-7 Standard WRH with Booster Option Sub Unit Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8 1-8 WRH-V Sub Unit Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-8 1-9 Fiber Optic Star Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9 1-10 Multi-operator System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-9 2-1 2-2 2-3 2-4 2-5 2-6 2-7 2-9 External Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 Cabinet Internal Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-1 CU PCBA LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 FON LED Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 DIA PCBA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 LNA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6 FON Connector Locations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-7 PSU Location. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-8 3-1 Mounting Bracket. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2 3-2 Mounting Bracket Installation on Wall . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-2 3-3 Attaching the Bracket to a Pole . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3 3-4 Attaching the Bracket to a Mast. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-3 3-5 Attaching the WRH to the Bracket . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-4 3-6 WRH Cable Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 3-7 WRH-V Cable Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-6 3-8 External Alarm Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7 3-9 Main Power Breakdown Relay Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8 3-10 PSU Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-8 3-11 Connecting a PC for Local Access . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9 4-1 RCU in the WRH Cabinet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-8 A-1 Standard WRH Block Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-1 A-2 WRH-V Block Digram - Non-diversity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-2 A-3 WRH-V Block Diagram - Diversity . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . A-3 List of Tables 2-1 CU PCBA LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-2 2-2 FON PCBA LED Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-3 2-3 WRH-V PCS Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4 2-4 WRH-V Cellular Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-4 2-5 DIA PCBA Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-5 2-6 BA PCBA Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6 2-7 DPX Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6 2-8 LNA Connections. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-6 2-9 FON Connectors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-7 2-10 Hardware/Software Compatibility . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-9 044-05251 Rev A iii List of Tables Wideband Radio Head 3-1 3-2 3-3 3-4 Cable Connection Procedure. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-5 Main Power Breakdown Relay Connection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-7 PSU Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-9 Initial Startup Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3-10 4-1 4-2 4-3 4-4 4-5 Recommended Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 Alarm Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-1 FON Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 PSU Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-6 WRH Replacement Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4-7 5-1 WRH Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5-1 iv 044-05251 Rev A Wideband Radio Head Abbreviations Abbreviations The following list of abbreviations are used throughout this manual, the software, and the repeater: AGC Automatic Gain Control ALI Alarm Interface AMPS Advanced Mobile Phone Service BA Booster Amplifier BeO Beryllium Oxide BMU Base Station Master Unit BS Base Station, BS antenna = towards the base station BSA Band Selective Amplifier BSel Band Selective BTS Base Transceiver Station CDMA Code Division Multiple Access CHE Channel Amplifier for GSM and EDGE CMB Combiner CSA Channel Selective Amplifier CSel Channel Selective CU Control Unit CW Continuous Wave DAMPS Digital Advanced Mobile Phone Service DC Directional Coupler DCS Digital Communication System (same as PCN) DIA Distribution Interface DL Downlink signal direction (from base station via repeater to mobile station) DPX Duplex filter EDGE Enhanced Data rates for GSM Evolution EEPROM Electrical Erasable Programmable Read Only Memory EGSM Extended Global System for Mobile communication ESD Electrostatic Discharge ETACS Extended Total Access Communication System ETSI European Telecommunications Standard Institute FLI Fiber Link Interface FON Fiber Optic Node FOR Fiber Optic Repeater FOU Fiber Optic Unit GSM Global System for Mobile communication HW Hardware ICNIRP International Commission on Non-Ionizing Radiation Protection LED Light Emitting Diode LNA Low Noise Amplifier MCPA Multi-Carrier Power Amplifier MS Mobile Station, MS antenna = towards the mobile station MSC Mobile Switching Center 044-05251 Rev A Abbreviations NEMA Wideband Radio Head National Electrical Manufacturers Association NiCd Nickel Cadmium NMT Nordic Mobile Telephone system NOC Network Operations Center OCM Optical Converter Module OMS Operation and Maintenance System PCN Personal Communication Network (same as DCS) PCS Personal Communication System POI Point of Interconnect PSM Power Supply Module PTFE Polytetrafluoro Ethylene (Teflon) R2R Repeater-to-Repeater RCI Remote Control Interface RCU Remote Control Unit RCM RF Converter Module RF Radio Frequency RIA Repeater-to-Repeater Adapter RMU Remote Master Unit RSSI Received Signal Strength Indication RTC Real Time Clock SW Software TACS Total Access Communication System TDMA Time Division Multiple Access UL Uplink signal direction (from mobile station via repeater to base station) UPS Uninterruptible Power Supply WHO World Health Organization WLI Wire Link Interface WRH Wideband Radio Head vi 044-05251 Rev A Chapter 1 Product Description Introduction This manual contains information and procedures for installation, operation, and maintenance of the Wideband Radio Head (WRH). The manual is organized into chapters as follows. Chapter 1 - Product Description Chapter 2 - Controls and Indicators Chapter 3 - Installation Chapter 4 - Maintenance Chapter 5 - Specifications Scope of Manual This manual is intended for use by service technicians familiar with similar types of equipment. It contains service information required for the equipment described and is current as of the printing date. Changes which occur after the printing date may be incorporated by a complete manual revision or alternatively as additions. Safety It is necessary that any personnel involved in installation, operation or service of units included in a Powerwave Distributed Antenna System (DAS) understand and follow the below points. 044-05251 Rev A • Powerwave WRHs are designed to receive and amplify signals from one or more base stations and retransmit the signals to one or more mobile stations. And, also to act the other way round, that is to receive signals from one or more mobile stations, amplify and retransmit the signals to the base stations. Powerwave WRH systems must be used exclusively for this purpose and nothing else. • Units supplied from the mains must be connected to grounded outlets and in conformity with the local prescriptions. • Power supply units supplied from the mains contain dangerous voltage that can cause electric shock. Disconnect the mains prior to any work in such a unit. Local regulations are to be followed when servicing such units. Authorized service personnel only are allowed to service units while the mains is connected. • The WRH cover must be secured in opened position, for instance by tying it up. Otherwise, the cover can be closed by the wind and cause your fingers getting pinched or your head being hit. • When working on a WRH on high ground, for instance on a mast or pole, be careful not to drop parts or the entire WRH. Falling parts can cause serious personal injury. • All RF transmitting units, including WRHs, will generate radio signals and thereby give rise to electromagnetic fields that may be hazardous to the health of any person who is extensively exposed close to an antenna. • A lithium battery is permanently mounted on the CU and FON PCBAs. Due to the risk of explosion, this battery must only be removed from the board by an Powerwave authorized service technician. • NiCd batteries are mounted on the FON PCBA. These batteries contain environmental poisonous substances. If replaced, the old batteries should be taken care of as stated in the local prescriptions. 1-1 Safety Wideband Radio Head • The FON unit contains a class IIIb laser transmitter that emits 2 – 4mW invisible laser radiation during operation. Avoid direct exposure from unconnected laser transmitter or fiber cord. • Do not power up the FON unit if a fiber cable is not attached to the fiber output UL port, neither if a fiber cable is attached to the port but unattached in the other end. • Never look in the end of a fiber cable. The 1310nm and 1550nm laser light is not visible, so no signal identification can be made anyway. Use always an instrument, such as a power meter to detect signaling. • Never use any kind of magnifying devices that can focus the laser light to an unaided eye. Human Exposure of RF Radiation Safe distances must be kept when working around antennas. The following paragraphs describe the cautions to be aware of during the installation and maintenance of antenna systems and how to calculate safety distances needed for RF radiation at different antenna power and frequencies. Antennas To be able to receive and transmit signals, a WRH is connected to a donor antenna directed towards the base station and a service antenna directed towards the coverage area. A fiber optic cable from the base station might, however, be substituted for the donor antenna. Installation and Maintenance of Antenna Systems Installation and maintenance of all antenna systems must be performed with respect to the radiation exposure limits for public areas. The antenna radiation level is affected by WRH output power, antenna gain, and transmission devices such as cables, connectors, splitters and feeders. Also have in mind the system minimum coupling loss, typically between 25dB and 35dB, is determined by a standard with the purpose to protect base stations from noise and other performance dropping effects. Radiation Exposure The World Health Organization (WHO) and International Commission on Non-Ionising Radiation Protection (ICNIRP) have determined recommendations for radiation exposure. ICNIRP recommends not to exceed the following radiation power for public exposure: FrequencyRadiation power 800/900 MHz 1800/1900 MHz 2100 MHz 4.5W/m² 9.0W/m² 10.0W/m² For antennas larger than 20cm the maximum radiation power can be calculated by using the following formula: S = --------------------2 4×π×r S = Radiation power in W/m² P = Output power in W r = Distance between antenna and human in meters Electrostatic Discharge (ESD) ESD can severly damage essential parts of the equipment if not handled carefully. Parts on printed circuit board assemblies (PCBA) as well as other parts in the equipment are sensitive to ESD. Never touch the PCBA or uninsulated conductor surfaces unless absolutely necessary. If you must handle the PCBAs or uninsulated conductor surfaces, use ESD protective equipment or first touch the chassis with your hand. Never let your clothes touch PCBAs or uninsulated conductor surfaces and always store PCBAs in ESD-safe bags. 1-2 044-05251 Rev A Wideband Radio Head Overview Overview Figure 1-1 Powerwave Wideband Radio Head (WRH) Powerwave WRHs work as bi-directional on-frequency amplifiers used to fill out uncovered areas in wireless mobile systems such as base station fringe areas, tunnels, convention centers, airports and business buildings. It receives, amplifies and transmits signals to/from a base transceiver station (BTS) to/from mobile stations (MS) with both directions being served simultaneously. Connections to the WRH are made with N-type or 7/16" male connectors. WRHs are microprocessor controlled with alarm and operational status LEDs visible on the front cover. Cooling is provided through convection heat dissipation. Operational parameters, such as gain, channel number and power levels are set using a PC running Powerwave OM-Online software which can communicate with the WRHs either locally or remotely via modem. Remote operation can be performed via PSTN or a GSM net. The Operation and Maintenance System (OMS) provides for Network Operations Center (NOC) configuration and alarm monitoring. WRHs can be configured in many combinations depending on the wireless system, single or double system operation, and output power. The following paragraphs provide a description of the different models of WRH’s available. WRH The Standard WRH is used for analog or digital systems such as GSM, TACS, ETACS, AMPS, DAMPS, CDMA and WCDMA. It can be equipped with two bands in the cabinet and two bands in a high cover. It has a fiber optic donor port and an RF port for a service antenna (or RF cable) and is designed to be connected to a BTS via a BMU or OCM. A booster option is available for the standard WRH to provide greater output power. This unit is equipped with a 6dB Booster Amplifier (BA) in the downlink path. The BA reduces the number of bands with one band per BA used in the cabinet and an additional one band if a high cover is used. The BA is located in the cabinet and is supplied from the existing PSU. For two bands, a high cover is used. WRH-V The WRH-V is designed to provide a higher output power level and comes equipped with a MCPA in the downlink path. The MCPA restricts the number of bands to one in the cabinet and one additional band if a high cover is used. The MCPA is located in the cabinet and is supplied from the existing PSU. For two bands, a high cover is used. 044-05251 Rev A 1-3 Overview Wideband Radio Head Chassis Design The WRH is housed in a cast aluminium waterproof chassis, class NEMA4 / IP65 approved for outdoor use but is also suited for indoor installations. The chassis consists of a cabinet and a cover attached with hinges. The cabinet contains the WRH circuitry. The cover comes as either a low or high version. The high cover can be used as an empty cover or be equipped as a part of the WRH or an independent WRH unit. A WRH with a high cover that is equipped as two independent units can, for example, be equipped for channel selective operation in the cabinet and band selective operation in the cover. Inside the WRH, a number of amplifier PCBAs are individually shielded and located under a metal cover that can be opened outward. These PCBAs are of different types depending on the supported system. Functionally, all WRHs are built up with a number of sub units. These are listed and described in the following sections. Sub Unit Overview A number of amplifier PCBAs are individually shielded and located under a metal cover inside the WRH. This cover can be opened outward for access. These amplifier PCBAs are of different types depending on the supported system. All of the WRHs are built up with a number of sub units which are described in the following sections. Wideband Amplifier PCBA (WBA) WRHs can handle multiple carriers over a wide band. Each band requires one WBA for the uplink and downlink, and one associated PA or MCPA for the downlink. The cabinet can be equipped with up to two WBAs along with two PAs supporting two bands or one MCPA supporting one band. Positions 1 and 3 are assigned for a WBA. Power Amplifier PCBA (PA) The PA is used to amplify the output signal from the WBA in the dowlink direction and reside in positions 2 and 4. Multi-Carrier Power Amplifier PCBA (MCPA) Installed in the WRH-V only, the MCPA is used to amplify the output signal from the WBA. Each MCPA can handle one band in the downlink direction. It requires an extra heat sink element on the outside of the cabinet or high cover to dissipate the heat generated. The MCPA occupies positions 2 through 4 in the cabinet and 6 through 8 in a high cover. Booster Amplifier PCBA (BA) A WRH can be modified with a BA on the DL path to increase the output power by 6dB (typically) depending on system configuration. This BA can operate with a maximum of 2 channels and occupies position 3 in the cabinet and position 7 in a high cover. It also requires an extra heat sink element on the outside of the cabinet or high cover. Some configurations use the existing PSU while others require a second PSU. Control Unit PCBA (CU) The CU is the core microprocessor controller in the WRH and is connected to P2 on the DIA. It contains a microprocessor, main memory, flash memory for the CU software, EEPROM memory for parameters, memory for the event log and statistics, a REFO reference oscillator, ports for local and remote communication, battery powered real-time clock, and MAC identity circuit. The CU supervises and controls operational parameters such as gain control and channel handling, alarms, event log, password and logon. The CU is also a control interface for OM-Online and OMS. Software for the CU can be downloaded from OM-Online, either locally or remotely, or from OMS. It is located in the lower right part of the shielded DIA frame. 1-4 044-05251 Rev A Wideband Radio Head Overview Figure 1-2 CU PCBA Distribution PCBA (DIA) The DIA is the core distribution PCBA on which all other PCBAs and units connect to in the cabinet with the exception of the PA. A shielded metal frame on the DIA provides the mounting location for the CU, ALI and RCIs, if used. P36 P11 P34 V2 P12 P13 P29 P14 P22 V1 XOB 16 V2 P28 P36 LED P22 P34 16 1 15 16 P5 P3 15 P26 16 16 P4 P2 32 P31 PC P32 M ODEM W6B 10 P21 PSU ALLGON INNOVATION SWEDEN M 105 R6 LNA DOWN-LINK V6 P24 GND V6 GND P35 PARKING FOR W5 P32 P24 10 P33 ALARM AUX1 W5 P27 16 P25 P29 15 P23 LNA UP-LINK V6B P25 15 P28 DOOR V1 16 P14 X0B P23 P27 16 P13 16 P6 X0A S->M P26 16 P12 P11 M->S XOA P33 P4 P5 P6 P2 P3 P21 P35 P31 Figure 1-3 DIA PCBA Low Noise Amplifier (LNA) LNAs are used on the uplink and are located at the top of the cabinet and the high cover, if equipped. All coaxial connectors are SMA-type. Signals from the DPX output are fed to the LNA input connector IN. OUT1 and OUT2 outputs feed the WBAs of the same signal direction. The signal level in these connectors are +20dB referenced to the antenna input. Another output, OUT LOW, is an expansion output for an additional LNA if the WRH is equipped in the cover part of the chassis. The gain to this connector is +2dB. The +7V input is used for +7V supply from the DIA PCBA and ATT is a control signal for a controllable attenuator in the LNA. Figure 1-4 LNA Duplex Filter (DPX) DPXs are located on the metal cover sheet in the upper part of the cabinet. Service and donor DPXs are identical. 044-05251 Rev A 1-5 Overview Wideband Radio Head Fiber Optic Unit (FOU) The FOU is a metal plate mounted on top of the cover plate in the upper part of the WRH. The FON and fiber optic connectors are mounted on the FOU. It can also be configured with combiners, splitters, and WDMs to obtain a desired combination of several branches with double or single fiber. Figure 1-5 FOU in WRH-V Fiber Optic Node (FON) The FON is the main part of the FOU. It is a bi-directional electrical/optical signal converter and a node in a fiber network. In addition, the FON has all the functionality included in the CU PCBA and contains battery backup. It has also functionality for: • • • • • • Electrical and optical signal supervision Internal and external alarm handling RS232 interface for local PC control via an O&M software (OM-Online) Remote control via an O&M software (OM-Online or OMS) Interfaces for RCU and FLI Battery backup with charger There are two versions of the FON; one with three SMA ports (UL, DL and RX Mon) and the other with four SMA ports (UL, DL, RX Mon and TX Mon). The FON has coaxial ports for DL and UL RF signals and two optical ports for DL and UL fiber connections. Power Supply Unit (PSU) A PSU is located in the lower center of the cabinet and, if configured, the high cover. Remote Control Unit (RCU) The RCU is an optional communication unit for remote control of WRHs via PSTN or RF modems. RCU types and details are described in Chapter 4. Alarm Interface PCBA (ALI) and Remote Control Interface PCBA (RCI) The ALI handles alarms and alarm communication. It is replace with an RCI if an RCU is used and provides an interface between the CU and an RCU for remote communication via modem. The RCI also handles alarms and alarm communication. Either unit is located in the lower left part of the shielded DIA frame. 1-6 044-05251 Rev A Wideband Radio Head Overview Sub Unit Locations WRH LNA - UL WBA DL/UL LNA - DL PA DL WBA DL/UL PA DL WBA DL/UL PA DL WBA DL/UL PA DL FON DPX DPX FOU ALI/RCI FON FOU CU PSU PSU (RCU) (RCU) Figure 1-6 Standard WRH Sub Unit Locations For single wideband operation the cabinet is equipped with a WBA in position 1 for both DL and UL paths and an associated PA in position 2 for DL signal amplification. For dual band operation another set of PCBAs can be used in positions 3 and 4. The WRH has a FON for uplink transmission via fiber optics. A high cover can be equipped as well providing up to four bands. PCBA positions are illustrated in the Figure 1-6 and a block diagram is located in Appendix A. The booster option boosts the output DL signal from the PA. The BA is located at position 3 in the cabinet. A booster can only be equipped for one band in the cabinet and an additional band in a high cover. PCBA positions are illustrated in the Figure 1-7 and a block diagram is located in Appendix A. 044-05251 Rev A 1-7 Overview Wideband Radio Head LNA - UL LNA - DL WBA DL/UL PA DL BA DL WBA DL/UL PA DL BA DL FON DPX FON DPX FOU ALI/RCI FOU ALI/RCI CU CU PSU PSU (RCU) (RCU) Figure 1-7 Standard WRH with Booster Option Sub Unit Locations WRH-V The WRH-V has a configuration similar to the standard WRH with the exception of a the MCPA that boosts the output DL signal from the PA. The MCPA is located at positions 3 and 4 in the cabinet. The MCPA requires an additional heat sink and is attached to the MCPA PCBA. A WRH-V can only be equipped for one band in the cabinet and an additional band in a high cover. PCBA positions are illustrated in the Figure 1-8 and a block diagram is located in Appendix A. LNA - UL WBA DL/UL MCPA DL WBA DL/UL FON DPX ALI/RCI FON DPX FOU CU MCPA DL FOU ALI/RCI CU PSU PSU (RCU) (RCU) Figure 1-8 WRH-V Sub Unit Locations 1-8 044-05251 Rev A Wideband Radio Head Overview Fiber Optic Distribution Networks Fiber optic networks are setup identically to data networks. WRHs are connected is a star configuration as illustrated in Figure 1-9. In this example, a Base Station Master Unit (BMU) is fed by a BTS via an RF cable. An Optical Converter Module (OCM) could also be used depending on the system configuration. The BMU or OCM contain three FONs and provide continuity to the FONs in the four WRHs. By using Wave Division Multiplexers (WDMs) and Optical Splitters (OSPs) in the WRHs, the distribution net can be built up with a combination of star and daisy-chain connections using double or single fiber. BMU WRH BTS RF WRH WRH WRH Figure 1-9 Fiber Optic Star Configuration Multi-Operator Configurations Multi-operator systems require the use of Point of Interconnects (POIs), RF Combining Modules (RCMs) and OCMs as illustrated in Figure 1-10. In this simple example, two operators have two sectors each. Each sector is connected to a POI and then to a RCM. The RCM is interconnected with an OCM via coaxial cables. The combined DL and UL signals are converted to optical signals in the OCM and then distributed to the WRHs. Additional information is provided in the Fiber Optic Equipment Operation and Maintenance Manual. OCM Operator 1 Sector 1 Sector 2 Operator 2 Sector 1 Sector 2 POI RCM POI POI RCM POI Figure 1-10 Multi-operator System 044-05251 Rev A 1-9 Overview Wideband Radio Head This Page Intentionally Left Blank 1-10 044-05251 Rev A Chapter 2 Controls, Indicators and Connectors Introduction This chapter contains descriptions of the controls, indicators and connectors for the WRH. Front Cover Indicators Amber Red Figure 2-1 External Indicators Two LEDs are located on the front cover to provide easy identification of a fault in the system. The amber operation LED lights up approximately 15 seconds after the main power is switched on. When the LED is steady, the WRH is ready for operation. The red alarm LED indicates a system error alarms when flashing and a critical alarm when steady. Cabinet Indicators POWER 16 OPER P36 S->M 16 16 P12 P34 LED P22 15 16 P3 15 16 P25 P29 P27 P32 MODEM W 6B P4 16 P2 32 P31 PC 10 P33 ALARM P21 PSU 10 AUX1 15 W5 16 P 23 LNA UP -LIN K 16 P5 15 P26 DPX P 28 D OOR V1 P14 X0B DC 16 P13 16 P6 CU V2 P11 X0A MS -20 dB FAULT BOOT TEST -30 dB POWER ALARM M->S ALI or RCI OPER FAULT 10V ALLGO N INNOVATION SW EDEN M105 R6 P24 LNA DOW N-LINK V6 DC DPX GND TEST -30 dB MS -20 dB P35 PARKING FO R W 5 ANT ANT POWER SUPPLY UNIT WLI / R2R DATA Figure 2-2 Cabinet Internal Indicators Figure 2-2 illustrates the LED indicators located on the ALI, or RCI, and CU PCBAs as well as the 115/220V main power switch (‘S’) in the cabinet. These indicators are described in further detail in the following sections. 044-05251 Rev A 2-1 PCBA Indicators Wideband Radio Head PCBA Indicators This following paragraphs describe the LED indicators on the main PCBAs inside the WRH. CU PCBA Figure 2-3 illustrates the location of the LEDs on the CU and Table 2-1 describes their indications. WLI DATA POWER BOOT FAULT OPER Figure 2-3 CU PCBA Indicators Table 2-1 CU PCBA LED Indicators LED Description WLI Wire Line Interface. A flashing green LED indicates the unit is receiving data over the subcarrier. A steady green LED indicates: the unit is currently not receiving any data, is currently not a control station or there is no other node in the network. DATA POWER Blue LED indicating data transmission in the W-net. Yellow LED indicating present power and remains steady after power is switched on. BOOT Steady red LED when the CU boots (10 – 15 seconds after main power is switched on), then flashing red (5 – 10 seconds), then off if no error is detected. If an error is detected LED will stay on. FAULT Flashing red LED for 15 – 20 seconds after main power is switched on. Flashes for less serious alarms (Error) and is on solid for fatal alarms (Critical). OPER Steady green LED indicates WRH is ready for operation. WARNING: A lithium battery is permanently mounted on the CU PCBA. Due to risk of explosion, this battery must not be removed. In case of battery malfunction, replace the CU PCB. FON PCBA The FON is illustrated in Figure 2-4 and the LED indicators are described in Table 2-2. 2-2 044-05251 Rev A Wideband Radio Head WRH-V PCBA Connections P117 Figure 2-4 FON LED Indicators Table 2-2 FON LED Indications LED Description FLI or F2F Green LED. Fiber Line Interface (FLI). Flashing LED indicates the unit is receiving data over the sub carrier. A steady LED indicates the unit has detected an FLI subcarrier, but is not carrying any data. OPER Green LED. Lights up for approximately 15 seconds after the mains is switched on. When steady, it indicates the unit is ready for operation. FAULT Red LED. Flashes for 15 – 20 seconds after the mains is switched on. Will flash for less serious alarms and be steady for fatal alarms. POWER Yellow LED. Indicates power is present BOOT Red LED. Steady LED when the control unit boots up (10 – 15 seconds after the mains is switched on). Next enters a flashing state for 5 – 10 seconds. If no error is detected, the LED is off. If an error occurs, the LED remains on. WLI Green LED. Wire Line Interface. Flashing LED indicates unit is receiving data over the subcarrier. A steady LED indicates one of the following: The unit is not currently receiving any data, the unit is not currently a control station or there is no other node in the network. DATA Blue LED. Indicates data transmission in the W-net BATT Green LED. Steady LED indicates battery pack is currently used as power source CHARGE Yellow LED. Steady LED indicates battery charging WRH-V PCBA Connections The following tables list the connections on the main PCBAs inside the WRH-V. Table 2-3 describes the connections for the WRH-V configured for PCS with diversity and non-diversity and Table 2-4 for Cellular with diversity and non-diversity. 044-05251 Rev A 2-3 WRH-V PCBA Connections Wideband Radio Head Table 2-3 WRH-V PCS Connections From To Cable Type Non-Diversity 800-15790-001 Diversity 800-15790-002 ANT M Duplexer M 1/4 super flex Used Used ANT D Duplexer D RG223 Not Used Used DuplexerM MCPA Out .141 conform Used Used DuplexerM LNA In RG223 Used Used DuplexerD LNA In RG223 Not Used Used M LNA Out WBA P2101 RG316 Used Used D LNA Out WBA P3101 RG316 Not Used Used MCPA IN WBA P1401 .086 conform Used Used WBA P2401 M FON P101 RG316 Used Used WBA P3401 D FON P101 RG316 Not Used Used WBA P1101 M FON P102 RG316 Used Used Table 2-4 WRH-V Cellular Connections 2-4 From To Cable Type Non-Diversity 800-16568-001 Diversity 800-16568-002 ANT M Duplexer M 1/4 super flex Used Used ANT D Duplexer D RG223 Not Used Used DuplexerM MCPA Out .141 conform Used Used DuplexerM LNA In RG223 Used Used DuplexerD LNA In RG223 Not Used Used M LNA Out WBA P2101 RG316 Used Used D LNA Out WBA P3101 RG316 Not Used Used MCPA IN WBA P1401 .086 conform Used Used WBA P2401 M FON P101 RG316 Not Used Not Used WBA P3401 D FON P101 RG316 Not Used Not Used WBA P1101 M FON P102 RG316 Not Used Not Used DX DL LO (M) WBA P1101 RG316 Used Used DX UL1 LO (M) WBA P2401 RG316 Used Used DX UL2 LO (D) WBA P3401 RG316 Not Used Used DX DL HI (M) Cable 327 RG316 Used Used DX UL1 HI (M) Cable 325 RG316 Used Used DX UL2 HI (D) Cable 326 RG316 Not Used Used DX DL C M FON P102 RG223 Used Used DX UL1 C (M) M FON P101 RG223 Used Used DX UL2 C (D) M FON P101 RG223 Not Used Used 044-05251 Rev A Wideband Radio Head WRH PCBA Connections WRH PCBA Connections The tables in the following sections list the connections on the main PCBAs inside the standard WRH. DIA PCBA Figure 2-5 illustrates and Table 2-5 lists the connections on the DIA PCBA. P36 P11 P34 V2 P12 P13 P29 P14 P22 V1 XOB 16 V2 P28 P36 LED P22 P34 16 1 15 16 P5 P3 15 P26 16 P25 16 P4 P2 32 P31 PC P27 P32 MODEM W6B 10 P21 PSU ALLGON INNOVATION SWEDEN M105 R6 LNA DOWN-LINK V6 P24 GND V6 GND P35 PARKING FOR W5 P32 P24 10 P33 ALARM AUX1 W5 16 15 P29 P23 LNA UP-LINK V6B P25 15 P28 DOOR V1 16 P14 X0B P23 P27 16 P13 16 P6 X0A S->M P26 16 P12 P11 M->S XOA P33 P4 P5 P6 P2 P3 P21 P35 P31 Figure 2-5 DIA PCBA Connectors and Testpoints Table 2-5 DIA PCBA Connections Port Connected to P2 CU PCBA P3, 5, 6 Not Used P4 P11 - 14 ALI or RCI PCBA Channel PCBA positions 1 through 4 P21 PSU, connector 1 P22 LED PCBA in cover P23 LNA/UL P24 LNA/DL P25 Expansion output port to cover circuitry. Only in cabinets. P26 Expansion input port to cover circuitry. Used in equipped high covers. P27 Auxiliary Port (8-pin male) - Pins 2 and 3 must always be interconnected to provide the CU and ALI/RCI PCBAs with voltage. If there is no cable connected, pins 2 and 3 must be interconnected with a jumper. P28 Door switch port - Normally, alarm input AI4 is used for door opening alarm EAL4 which is arranged using an optional door switch. Signal AI4 and AIC are thus available also in the P28 connector, to which the door switch is connected. The EAL4 door switch alarm is activated 10 – 30 seconds after the cover has been opened. P29 Power to FON P31 RS-232 PC Port (9-pin D-sub female) - Used for local PC communication. P32 RS-232 Modem port (9-pin D-sub male) P33 External Alarm Port (15-pin D-sub female) - Used for external alarm sensors and alarm equipment. Four alarm inputs, EAL1 – EAL4, and two alarm outputs. P34 Not used P35 PSU, connector 2 P36 Not used 044-05251 Rev A 2-5 WRH PCBA Connections Wideband Radio Head BA PCBA Table 2-6 lists the connections for the BA PCBA. Table 2-6 BA PCBA Connections Port Connected to P3 P5 on the PA/DL PCBA P4 HI on the service DPX DPX Table 2-7 lists the DPX connections. DPXs are located on the FOU in the upper part of the cabinet. Table 2-7 DPX Connections Service DPX for Non-diversity ANT Connected to Service antenna (or DPX on the service (MS) DC HI Connection from the MCP or PA LO IN on the LNA/UL Secondary DPX for Diversity ANT Connected to Service diversity RX1 antenna HI Not used LO Connection to LNA LNA Figure 2-6 illustrates the front of the LNA and Table 2-8 defines the connections. Figure 2-6 LNA Table 2-8 LNA Connections LNA Port Connected to OUT LOW IN on the LNA/UL in the cover, if equipped IN ATT +7V OUT1 LO on the service DPX duplex filter. P23 on the DIA PCBA. P2101 on the WBA PCBA. FON Figure 2-7 illustrates the locations of the connectors on the FON and Table 2-9 defines the port numbers, connector types, and port usage. 2-6 044-05251 Rev A Wideband Radio Head WRH PCBA Connections P117 Figure 2-7 FON Connector Locations Table 2-9 FON Connectors Port Description P101 SMA, electrical RF input port (to the optical TX port) P102 SMA, electrical RF output port (from the optical RX port) P103 SMA, electrical RF output port (15dB below the P102 port) RX DIN/APC, optical input port (to the P102 and P103 RF ports) TX DIN/APC, optical output port (from the P101 RF port) P104 Used only for development and debugging P105 4-pin male, door LED indicators. Used for the yellow and red LED indicators located on the front cabinet door P106 9-pin D-sub female, RS-232 used for local PC communication P108/116 6-pin male, parallel connected power ports for the FON P109 7-pin male, used for external alarm sensors P110 W-link jumper, used to terminate units in a W-link. It has to be set in the parking state for all units except for the first and last units in a W-link. The Parking state (P) has the jumper between the center and bottom pins. The opposite state (T) terminates the W-link. P111/112 5-pin male, WLI ports used for interconnecting nodes in WLI-nets (IP or R2R networks). They are identical and connected in parallel. One of the connectors are intended to be used from the previous node and the other connector to the next node in the network. Either can be used for the first and the last unit in the net chain. P113 2-pin male, used for the on-PCBA backup batteries. P114 Backup power output jumper, sets the backup power output state. The OFF state has jumper between the center and left pins. This jumper has to be in the OFF state when used in an OCM. Otherwise, it shall be in the ON state. P115 3-pin male, future port - intended for future use P117 SMA, electrical RF input port (15dB below the P101 port) P130 34-pin, 2-line male, RCU port used for connecting an RCU. The connector contains both the modem connection and RCU power supply. PSU The PSU is located in the bottom middle of the cabinet or in an equipped high cover. The PSU has all the voltages required for the WRH. It has capacity for the radio circuitry, fiber optics, modem, etc., and also supplies the BA if used. Multi-band WRH-Vs always require a second PSU. There are two PSU types with different input voltages: 044-05251 Rev A 2-7 WRH PCBA Connections Wideband Radio Head 1. 115/230V 50/60Hz, 300W input max. 2. 21- 60V DC, 300W input max. The DIA provides most of the internal connection between the sub units and external ports. Connectors involved are also located on the DIA. Refer to Table 2-6 for descriptions of the connectors. P34 P36 16 V2 P36 S->M P34 16 LED P22 16 1 P28 DOOR 16 P5 P3 16 P4 16 P2 32 P31 PC MS -20 dB P32 M ODEM W6B 10 W5 P21 PSU A LLGON INNOV ATION SWEDEN M 105 R6 P24 LNA DOWN-LINK V6 DC DPX 10 P33 ALARM AUX1 P33 P27 16 P25 P29 DPX 15 P23 LNA UP- LINK TEST -30 dB 15 15 P26 DC V1 P14 X0B 15 P32 16 P13 16 P6 X0A M->S 16 P12 P11 P31 P28 GND TEST -30 dB MS -20 dB P35 PARKING FOR W5 ANT ANT P27 POWER SUPPLY UNIT Figure 2-8 PSU Location The External Alarm Port P33 is used for external alarm sensors and alarm equipment. The four alarm inputs are low-level inputs with common ground (AIC). Use an insulated switch or relay to initiate alarms (open switches in normal operating mode, closed switches cause alarm). The alarm switch connection can be toggled between active open and active closed. The alarm input voltage ratings, related to ground (AIC), are: Vinmax= 5.5V, Vinmin= –0.5V. The four alarm inputs are connected to the following pins: Pin 14 AI1 External alarm input 1 - EAL1 Pin 15 AI2 External alarm input 2 - EAL2 Pin 7 AI3 External alarm input 3 - EAL3 Pin 8 AI4 External alarm input 4 - EAL4 Pin 6 AIC Ground. Two alarm outputs are 1 pole closing and 1 pole opening relay outputs insulated from each other. Maximum ratings, related to ground or any other alarm terminal, are 50V AC / 60V DC. The alarm outputs are defined as follows: Pin 9 and 1 AO1 and AO8 Closed when operating, otherwise open. Pin 10 and 2 AO6 and AO7 Open when operating, otherwise closed. Pin 11 and 3 AO2 and AO5 Closed at alarm state, otherwise open. Pin 12 and 4 AO3 and AO4 Open at alarm state, otherwise closed. 2-8 044-05251 Rev A Wideband Radio Head Software and Hardware Compatibility Software and Hardware Compatibility There are different versions of CU PCBA software which can be combined with PCBAs of various revisions. These have unique part numbers and revision information. Below, you will find a table of software currently available in combination with CU PCBA revisions. Table 2-10 Hardware / Software Compatibility CU PCBA part # CU Software part # K103/3 (500-13817-001) SA102 06/x SA102 07/x SA102 08/x Comments More memory. MAC ID is added on the PCBA. R2R functionality integrated. This information is accurate as of 01/31/2007. As new versions of hardware and software are released without prior notice. Contact your Powerwave sales representative if in doubt about the latest revision status. For detailed information, refer to the release notes for the CU software to be downloaded (normally found in the readme.txt file provided with the program files). 044-05251 Rev A 2-9 Software and Hardware Compatibility Wideband Radio Head This Page Intentionally Left Blank 2-10 044-05251 Rev A Chapter 3 Installation Introduction This chapter contains unpacking, inspection and installation instructions for installing and powering up the WRH. Site Survey Powerwave recommends that a site survey be performed prior to equipment ordering or installation. Performing a detailed site survey reduces or eliminates installation and turn-up delays. Pay particular attention to power plant capacity, cooling needs, floor space, and RF/DC cabling/breaker requirements. Cabinet dimensions, clearance dimensions, and weights are listed in Chapter 5. Unpacking and Inspection This equipment has been operated, tested, and calibrated at the factory. Carefully open containers to remove equipment. Retain all packing material that can be reassembled in the event unit must be returned to the factory. Perform the following steps: • Visually inspect equipment for damage that may have occurred during shipment. If possible, in the presence of the delivery person. • Check for evidence of water damage, bent or warped chassis, loose screws or nuts, or extraneous packing material in connectors. If equipment is damaged, file a claim with the carrier once the extent of any damage is assessed. If equipment must be returned to factory, please contact factory for a Return Material Authorization (RMA). See Chapter 4. WRH Location The WRH is designed with a weather proof outdoor cabinet that can be mounted without any kind of shelter from rain, snow or hail. The same unit can be installed indoors. A preferable site for the WRH is a location free of obstructions, easily accessible and allows for proper air-flow and ventilation. If a WRH is installed outdoor and can be exposed to direct sunshine, it is essential that air can circulate around the WRH with no obstacle. The operating temperature must not exceed 131°F (55°C). A shelter can be used to shade the WRH from direct sunshine. Never open a WRH when rain, snow, hail, high humidity or high winds are present unless some kind of temporary shelter can be erected. Limitations for very bad weather are found in the next section. Mounting The WRH is easy to mount using the provided mounting bracket, which has 9/16-inch (14mm) holes for 3/8-inch (10mm) or 1/2-inch (12mm) fixing screws. Clamps with C-C measures of 3.5-inch (90mm), 5.3-inch (135mm), 5.7-inch (144mm), 8.1-inch (205mm), 9.8-inch (250mm), and 11.8-inch (300mm) can be used as well. The vertical C-C measure for these are 16.2-inch (411mm). There is a 9/16-inch (14mm) single hole in the middle of the mounting bracket, marked ‘A’ in the figure, which is intended for a locking screw to lock the bracket into place. 044-05251 Rev A 3-1 Mounting Wideband Radio Head 411 Ø14 90 135 144 205 250 300 Figure 3-1 Mounting bracket Normally, the WRH is mounted on a wall, pole, or mast. Figure 3-2 illustrates the installation of the mounting bracket on a wall using four fixing screws and a locking screw. Figure 3-2 Mounting bracket installation on wall 3-2 044-05251 Rev A Wideband Radio Head Mounting Figure 3-3 illustrates the installation of the mounting bracket on a pole using two 5.7-inch (144mm) Ushaped clamps and a locking screw. Figure 3-3 Attaching the bracket to a pole Figure 3-4 illustrates a mast installation using two 11.8-inch (300mm) bar-shaped clamps and no locking screw. Figure 3-4 Attaching the bracket to a mast 044-05251 Rev A 3-3 Connections Wideband Radio Head After installing the mounting bracket, hang the WRH on the upper supports, as illustrated in Figure 35. Tighten the upper and lower mounting screws to secure it into place using the 6mm hex socket wrench. Locking cylinders, used to prevent unauthorized removal of the repeater, can be inserted and locked with a key after the lower screws have been tightened. Make sure the donor antenna, directed towards the BTS antenna, and the service antenna, directed towards the area to be covered by the WRH, are mounted and installed properly. Figure 3-5 Attaching the WRH to the bracket Connections This section describes general examples of how to connect the input and output ports on the WRH. Main Power and Grounding Local regulations need to be followed for the main power connection. WRHs are approved in accordance with EN and UL/cUL regulations. This is, however, only valid if a classified power cord is used. For the WRH to meet these regulations you must select one of the following classified and approved cord types: • EN – H 05 W5 - F HMR • UL – AWM Style 2587 • CSA– AWM 1 A/B 11 A/B For outdoor use, the power cord should meet at least IP65 encapsulation requirements. Do not turn the main power on until you are ready to commission the WRH WARNING: For WRHs supplied from the main power source, the main outlet must be grounded. 3-4 044-05251 Rev A Wideband Radio Head Connections Fiber Optic and RF Connections Fiber optic and RF cable connections should be verified both internally and externally before powering up the equipment. This section illustrates the general internal connections of the WRH and WRH-V. Verify these connections with the as-built drawings and documents for your specific system configuration. Table 3-1 lists the steps for external connections to the WRH. Table 3-1 Cable Connection Procedure Step Action Connect the service antenna coaxial cable to the left in the cabinet using an N-type male connector. Connect the fiber optic cable from the OCM or BMU to the fiber optic cable demark on the FOU. Connect station ground. Mount the main power plug to the main power cord and connect it to the PSU. WRH Figure 3-6 illustrates the cables and connections for a standard WRH. Figure 3-6 WRH Cable Connections 044-05251 Rev A 3-5 Optional Connections Wideband Radio Head WRH-V Figure 3-7 illustrates the cables and connections for the WRH-V. Figure 3-7 WRH-V Cable Connections Optional Connections Alarms Alarm signals from external sensors are received by an ALI or RCI which forwards them to the CU. The RCI is used if the WRH has an RCU, otherwise the ALI is used. The software on the CU can activate acoustic or visual alarms or direct the alarm to the P33 alarm port for forwarding via an RCU to an OM-Online or OMS workstation. Alarms can also be handled by the FON. Alarms can be configured from an OM-Online or OMS workstation. External Alarm Burglary, fire or other external alarms can be handled by the WRH. External alarm sensors and alarm signals are connected to the P33 alarm port located to the left in the cabinet, as illustrated in Figure 38. The P33 alarm port is described in Chapter 2. The cable for this installation is taken through a strain relief bushing at the bottom of the WRH cabinet. Door Open Alarm A door open alarm can be configured and installed in the WRH. This is arranged with a door switch connected to P28, as illustrated in Figure 3-8. 3-6 044-05251 Rev A Wideband Radio Head Optional Connections P28 P33 16 V2 P36 S->M 16 P34 P14 LED P22 16 1 P28 DOO R P26 P3 16 15 P4 16 P2 32 P32 MODEM W6B 10 P31 PC P21 PSU W5 AL LGON INN OVATION SWEDEN M105 R6 P24 LNA DOWN-LINK V6 DC DPX 10 P33 ALARM AUX1 MS -20 dB P27 TEST -30 dB P25 P23 LNA UP-LINK DPX 16 15 P29 DC 16 P5 15 X0B 15 V1 16 P13 16 P6 X0A M->S 16 P12 P11 GND TEST -30 dB MS -20 dB P35 PARKING F OR W5 ANT ANT POWER SUPPLY UNIT Figure 3-8 External alarm connection Fiber Link Interface (FLI) The FLI feature makes it possible to interconnect WRHs. By using an RF distribution fiber network, no wire or other communication device is required. Main Power Breakdown Relay To be able to distinguish PSU faults from power failure, a main power breakdown relay can be used. This relay is not included in the WRH. It has to be mounted outside the WRH cabinet. The relay intended for this purpose must fulfil the following specifications: Closing time: Max. 30 milliseconds Insulation coil/contact: Min. 4KV A main power connected relay must also be in compliance with valid local regulations. Table 3-2 Main Power Breakdown Relay Connection Step Action Connect a current less closed relay contact to pin AI1 and AIC on the P33 alarm connector, see Figure 3-11. Alarm is initiated by short-circuiting pin AI1 and AIC in the P33 port. Connect the relay coil. It must be supplied from the same fuse as the WRH After commissioning, select Mains Breakdown in the alarm configuration window in OM-Online or OMS. Refer to the OM-Online User Manual 044-05251 Rev A 3-7 Optional Connections Wideband Radio Head P33 16 V2 P36 S->M X0A 16 P34 LED P22 P28 DOOR 15 P26 16 15 P27 P25 P29 P32 MODEM W6B 10 16 P4 P2 W5 LNA DOWN-LINK V6 P31 PC 10 P33 ALARM P21 PSU ALLGON INNOVATION SWEDEN M105 R6 P24 32 AUX1 16 15 TEST P3 DPX -30 dB 16 P5 P23 L NA UP -LINK DC V1 P14 X0B 16 1 15 MS -20 dB 16 P13 16 P6 M->S 16 P12 P11 GND P35 PARKING FOR W5 ANT POWER SUPPLY UNIT P33:AI1 P33:AIC Figure 3-9 Main power breakdown relay connection 21-60 Volt DC PSU Installation The 115/220 VAC PSU can be replaced with a 21 to 60 VDC DC PSU as described below. 16 V2 P36 S->M X0A 16 P34 16 1 LED P22 P28 DOOR P3 16 P4 16 P2 32 P32 MODEM W6B 10 P31 PC W5 P21 PSU ALLGON INNOVATION SWEDEN M105 R6 P24 LNA DOWN-LINK V6 DC DPX 10 P33 ALARM AUX1 MS -20 dB P27 16 P25 P29 15 DPX TEST -30 dB 15 P23 LNA UP-LINK DC 16 P5 15 P26 V1 P14 X0B 15 16 P13 16 P6 M->S 16 P12 P11 GND TEST -30 dB MS -20 dB P35 PARKING FOR W5 ANT ANT POWER SUPPLY UNIT PSU Figure 3-10 PSU Connections 3-8 044-05251 Rev A Wideband Radio Head Commissioning Table 3-3 PSU Replacement Procedure Step Action Disconnect main power Remove the main power plug from the PSU ('1' in Figure 3-12) Disconnect the power cable bundle connectors (2) on the PSU Loosen the four fixing screws (3) using a 5mm Allen key and remove the PSU Examine the removed PSU and identify the supply voltage for the WRH (13.5V or 27V) Set the new PSU to the correct supply voltage by moving the jumper as illustrated on the PSU. This must be done before the PSU is mounted in the WRH Mount the PSU with the four fixing screws (3) Connect the PSU to the DIA PCBA (2) with a cable marked VE007 98/1. This cable must be used even if one connector will be left over at the DIA PCBA (previous versions of the DIA had only one connector) 10 Connect the DC power cable. The supplied cable should have a radiation limiter. The + pole should be connected to one of the left terminals in the PSU connector with the brown part of the DC cable. The – pole should be connected to one of the right terminals in the PSU connector with the blue part of the DC cable 11 Apply power and verify the yellow LED on the PSU lights Commissioning Before proceeding, carefully read the Safety section and check all connections made during the installation. To fulfill the IP65 weather protective requirements, ensure cable strain relief bushings are properly tightened. Also, ensure gaskets at cable inlets and on the cabinet are properly fitted and not damaged. A WRH can be configured locally with OM-Online by connecting a standard serial cable from the COM port on the PC to the P31 PC port (RS-232) located to the right in the cabinet (see Figure 3-14). The P31 PC port is described in Chapter 2. OM-Online is described in the OM-Online User Manual. P31 16 V2 S->M P34 P27 15 15 16 P25 P32 MODEM W 6B 10 P4 16 P2 32 P31 PC 10 P33 ALARM P21 PSU AUX1 16 W5 P3 P29 DPX TEST 16 P5 P23 LNA UP-LINK DC MS -20 dB 15 P26 -30 dB P28 DOOR V1 LED P22 16 P6 X0B 16 1 15 16 P14 X0A 16 P13 M->S P36 16 P12 P11 ALLGON I NNOVATIO N SW EDEN M105 R6 P24 LNA DOW N-LINK V6 GND P35 PARKING FOR W 5 ANT POWER SUPPLY UNIT Figure 3-11 Connecting a PC for Local Access 044-05251 Rev A 3-9 Commissioning Wideband Radio Head Initial Startup Table 3-4 Initial Statup Procedure Step 3-10 Action Turn the main power on Check the Yellow LED on the power supply unit. It must be a steady on Check the four CU PCBA LEDs. Refer to the CU PCBA section in Chapter 2 for the correct power up indications Check the three ALI PCBA LEDs or the corresponding LEDs on the RCI PCBA. Refer to the ALI or RCI PCBA section in Chapter 2 for the correct power up indications. The LEDs follow the alarm relays. 044-05251 Rev A Chapter 4 Maintenance Introduction This chapter contains periodic maintenance and performance test procedures for the WRH. Periodic Maintenance Periodic maintenance requirements are listed in Table 4-1, as well as the intervals at which the tasks should be performed. Table 4-1 Recommended Periodic Maintenance Task Interval Action Inspection of cables and connectors 12 months Inspect power, RF and Fiber cables for signs of damage or wear (frayed insulation, cracks, punctures, etc.) Check connections to be sure they are tight. Optional Perform cable sweeps. Clean equipment Clean as required depending on operating environment. Troubleshooting The sections that follow contain a list of problems that could occur and a few suggested actions that can correct the problem. If the suggested corrective action does not eliminate the problem, please contact your Powerwave field representative or help line for further instruction. Clearing Alarm Faults Table 4-2 contains a list of those alarms which can be generated in the WRH. Critical, Error and Warning alarms can be sent automatically from a WRH to OM-Online and/or OMS, stored and then viewed. These can be viewed in the Alarm window. Table 4-2 Alarm Troubleshooting ID Alarm Text Alarm Unit Alarm Description Power PSU Critical PSU1 in the cabinet does not work properly. A sum signal from the PSU1 indicates that at least one voltage output has dropped. If no mains breakdown relay is used, then the alarm will also be sent at mains breakdown. Ceasing PSU1 in the cabinet works properly again. Ceasing is sent if the PSU1 works at start-up, and there is a corresponding critical PSU1 alarm logged in the Events log. The WRH will restart when the power is back and this alarm will be sent. Critical PSU2 in the cover does not work properly. A sum signal from the PSU2 indicates that at least one voltage output has dropped. If no mains breakdown relay is used, then the alarm will also be sent at mains breakdown. PSU 044-05251 Rev A 4-1 Troubleshooting Wideband Radio Head FON 4-2 WRH restart Mains breakdown CU External Ceasing PSU2 in the cover works properly again. Ceasing is sent if the PSU2 works at start-up, and there is a corresponding critical PSU2 alarm logged in the Events Log. The WRH will restart when the power is back and this alarm will be sent. Error The FON 10 Volt charger voltage is below limit. Suggested remedy: Replace the FON Ceasing The cause of the alarm has ceased. None Power on start, or user ordered reboot. Logged to indicate a normal power up, or a restart ordered by the operator. Warning Software error restart, 1st – 7th time. Restart 1st to 7th time during a 14 day period. The counter is reset every 14th day, counted from power up. Error Software error restart 8th – 10th time. Restart 8th to 10th time during the 14 day period. At the 11th time, the SW bank will be blocked and not used anymore until a user ordered reset is performed, or power is switched off/on. Critical The mains power is gone. Used with an external relay indicating mains breakdown. The external relay should be connected to External Alarm 1 and the WRH configured to indicate this alarm. If no relay is used, a mains breakdown will be reported as a PSU fault. Ceasing The mains power is back. Sent if there is a corresponding critical mains breakdown alarm logged in the Events Log. The WRH will restart when the power is back. Alarm reset CU None Alarm reset by the user. All alarms are reset. The cause of the alarm will be re-evaluated and reported, if still active. Local bus error WBA #, PA#, MCPA# Error Error when communicating on the bus. The CU has no contact with the WBA, PA or MCPA PCBA, which is taken out of service. Main bkd w backup External Error Used to indicate that the mains is no longer available. WRH is powered by external battery backup unit. Suggested remedy: Check the mains power. Ceasing The cause of the alarm has ceased. Err in ADconverter Warning The analog-to-digital converter on the CU PCBA does not give reliable values. New unit detected None Compared to the last power on, the CU has recognized at least one additional hardware unit. Inst. unit lost Error Compared to the last power on, the CU lacks at least one hardware unit. 10 EEPROM error Error EEP read or write fail. Data cannot be written or read from the EEPROM on the CU PCBA. User parameters are stored in the EEPROM. 11 Log memory fault Error Log memory fault. Indicates that the log memory on the CU PCBA is faulty. The WRH will not work. Not available in all CU software versions. 12 High temp Warning The CU PCBA temperature is higher than 90°C. CU CU 044-05251 Rev A Wideband Radio Head Troubleshooting Ceasing The CU PCBA temperature has fallen below 90°C. 13 REFO error Error Significant REFO drift or error detected by CU. 14 Ext refo error Warning Suggested remedy: Check the reference source and the cables. 15 CU battery fault Warning CU RAM battery fault. The battery for the RAM on the CU PCBA has a voltage outside the normal 2.7 to 3.5 Volt. An alarm may be initiated at start-up if the WRH has been stored out of power for a long time. Suggested remedy: Ensure jumper P3 on the CU PCBA is mounted to charge the battery. Ceasing The cause of the alarm has ceased. CU 16 SW load error CU Error Software load error. An error has occurred during a software load process. The flash memory does not contain a proper software. Suggested remedy: Check the CU software using the OM-Online SW Manager. Do NOT restart the WRH. 17 Log cleared CU None Log memory has been cleared. The check sum in the Events Log memory is faulty. The log is cleared. Can be caused of a bad RAM battery backup or low voltage to the RAM. 18 RTC restarted CU None The time is changed by the operator (logged to keep track of changes made to the RTC). Warning Time reset to 1994-01-01. The RTC was unable to keep track of the time and did a reset. Suggested remedy: Ensure jumper P3 on the CU PCBA is mounted to charge the battery. Error RTC does not operate. The CU has detected an error in the RTC operation which makes the time unreliable. Suggested remedy: Replace the CU PCBA. Config The door has been open 30 seconds without disabling the alarm. Ceasing The door has been closed 30 seconds, or the alarm is disabled. Config External alarm input EA1 active more than 1 second. Ceasing External alarm input EA1 no longer active. Config External alarm input EA2 active more than 1 second. Ceasing External alarm input EA2 no longer active. Config External alarm input EA3 active more than 1 second. Ceasing External alarm input EA3 no longer active. Config External alarm input EA4 active more than 1 second. Ceasing External alarm input EA4 no longer active. 19 RTC error 20 Door open alarm 21 22 23 24 External alarm 1 External alarm 2 External alarm 3 External alarm 4 044-05251 Rev A External External External External External 4-3 Troubleshooting 30 No modem found Remote ctrl None No modem found, that is no answer is returned on a poll string to the modem. 33 No connection Remote ctrl None No connection at callback. The WRH has tried to call as many times as stated in the alarm call settings. No connection was established. Warning No connection at alarm call. The WRH has tried to call as many times as stated in the alarm call settings. No connection was established. This alarm does not generate a new attempt to report alarm by alarm call. None Invalid WRH password. 34 Login failed 35 Remote connection Remote ctrl None Modem connection to OM-Online opened. Not logged on CU2. Login Registry gives the same function and more information about CU2. 36 Modem init failed Remote ctrl None Initiation string to modem not OK. The initiation string sent to the modem is not OK. The string may contain commands not recognized by the modem. An alarm might be sent anyway. Suggested remedy: Check the modem using the OM-Online or OMS modem debugger. 37 Remote timeout Remote ctrl Warning The time limit of 20 minutes is exceeded without extending the timer. The modem connection is terminated by the WRH. 38 PIN code failed Remote ctrl Warning The PIN code sent to MS is incorrect. To unlock the MS/SIM card, the PUK code will probably be needed. Ceasing The cause of the alarm has ceased. Warning When using a PC-card together with the MS, the alarm indicates contact with the PC-card, but MS is not present or turned off. Note: A Nokia MS does not power-up after power failure. Suggested remedy: Ensure the cellular phone is connected. Ceasing The cause of the alarm has ceased. Error The backup battery on the RCU or the FON PCBA does not work properly. Suggested remedy: Check cables or replace battery. Ceasing The cause of the alarm has ceased. Warning Low antenna isolation. The antenna isolation is lower than the gain set. Gain is reduced by 10dB – 13dB below the oscillation point. Suggested remedy: Decrease gain or increase antenna isolation. Error Low antenna isolation at lowest gain. The gain has been reduced as much as possible but the oscillation still remains. The amplifier is turned off. Suggested remedy: Decrease gain or increase antenna isolation. Ceasing Normal operation again, that is no oscillation can be detected 13dB above the gain set. 39 40 42 4-4 Wideband Radio Head No phone detected Battery fault Antenna isolation Remote ctrl RCU, FON charger WBA #, Channel #, UL/DL 044-05251 Rev A Wideband Radio Head 48 50 Battery backup fault Fiberoptical error Troubleshooting External FOT fiber optics Error If a battery backup unit alarm is connected to external alarm 2, then the operator can configure the WRH to display this alarm when the battery backup unit indicates alarm. Ceasing The cause of the alarm has ceased. Configurable If a fiber unit alarm is connected to external alarm 3, then the operator can configure the WRH to display this alarm when the fiber optical unit indicates alarm. Ceasing The cause of the alarm has ceased. 70 Bad table alarm CU Error Requested table contains incorrect information (SW error). 71 Table not found CU Error Requested table not found in the database (SW or calibration error). 72 Table database error CU Error Table database not found (calibration error). 80 Antenna SWR alarm Donor antenna service antenna Error Too low antenna return loss, caused either by cables, connectors, or antenna problems. Suggested remedy: Check antenna and cables. Ceasing The cause of the alarm has ceased. Error A DC voltage on a FON PCBA is out of range. Suggested remedy: Replace the FON PCBA. Ceasing The cause of the alarm has ceased. Error Laser transmitter control loop voltage out of range. Suggested remedy: Replace the FON PCBA. Ceasing The cause of the alarm has ceased. Warning Received optical level is below any of the two limits (one for Warning and one for Error). Suggested remedy: Check optical cables. Error Received optical level is below any of the two limits (one for Warning and one for Error). Suggested remedy: Check optical cables. Ceasing The cause of the alarm has ceased. 90 91 92 FON power alarm FON TxStable alarm FON RxLevel alarm FON RF FON RF FON 93 FON SPI alarm FON F2F Error The SPI bus connection to the RF modem does not work properly. Suggested remedy: Replace the FON PCBA. 245 Not In Allowed Area CU None WRH is moved from the operating area and the RF HW is switched on or off. Remarks: The Door open alarm requires an optional door switch described in the P33 Alarm Port section in Chapter 5. The Main power breakdown alarm requires a relay not included in the WRH (see Main Power Breakdown Relay in Chapter 3). 044-05251 Rev A 4-5 Field Replaceable Units Wideband Radio Head Field Replaceable Units The following units can be replaced in the field on-site by a qualified technician with experience maintaining RF equipment: • FON • PSU • WRH FON To replace a FON PCBA, proceed as described in the Table 4-3. Table 4-3 FON Replacement Procedure Step Action Open WRH door and secure Locate power connector on FON and remove connector from PCBA Verify all cables on FON are labeled before disconnecting, then disconnect all cables. CAUTION: Do not look into the end of any fiber optic cable. Be sure to cap fiber optic cables to protect the connecting end from damage. Remove screws securing FON PCBA to FOU and remove PCBA Replace FON PCBA in reverse order and apply power Connect PC to OM Online port, login to FON and verify configuration and IP address. NOTE: Make sure ‘Fiberoptical’ classmark in the FON Status window is checked, otherwise FON will not be operational. Close WRH door and secure PSU To replace a PSU, proceed as desribed in the Table 4-4. Table 4-4 PSU Replacement Procedure Step 4-6 Action Open WRH door and secure Disconnect main power plug from PSU Disconnect power cable bundle from PSU Loosen screws securing PSU using a 5mm Allen key and remove. NOTE: screws are designed to not be removed completely from PSU. Replace PSU in reverse order and apply power Close WRH door and secure 044-05251 Rev A Wideband Radio Head Return For Service Procedures WRH To replace a WRH, proceed as desribed in the Table 4-5. Table 4-5 WRH Replacement Procedure Step Action Open WRH door and secure Disconnect main power plug from PSU Verify all cables connected to WRH are labeled before disconnecting, then disconnect all cables Remove mounting screws from bottom legs of WRH and loosen mounting screws in top legs Close and secure door WARNING: A fully loaded WRH can weigh 96lbs. Lifting of the WRH should be done by two people. Do not attempt to carry the WRH up a ladder. Lift the WRH off the mount hinges Replace WRH in reverse order Connect PC to OM Online port and verify configuration. For Fiber Optic installations, verify IP address. Close WRH door and secure Return For Service Procedures When returning products to Powerwave, the following procedures will ensure optimum response. Obtaining an RMA A Return Material Authorization (RMA) number must be obtained prior to returning equipment to the factory for service. Pease contact our Repair Department at 1-714-466-1000 to obtain this number, or FAX your request to 1-714-466-5800. Failure to obtain this RMA number may result in delays in receiving repair service. Repackaging for Shipment To ensure safe shipment of the unit, it is recommended that the original package designed for shipping the unit be reused. If it is not available, contact Powerwave’s Customer Service Department for packing materials. Remote Control Unit (RCU) The RCU provides remote control of Powerwave WRHs. It contains an integrated mobile phone, modem and power supply backup. The RCU is installed in the bottom front of the cabinet, on top of the PSU as illustrated in Figure 4-1. The RCU is connected to P130 on either an RCI or FON. A jumper is required between pins 1 and 2 on the RCI if the P130 cable connector is disconnected. If a main power failure occurs, the unit has a battery with enough capacity for sending a number of alarms. 044-05251 Rev A 4-7 Remote Control Unit (RCU) Wideband Radio Head 16 V2 P34 15 16 P5 P3 15 P26 16 P27 P4 16 P2 32 P31 PC P32 MODEM W6B 10 P21 PSU ALLGON INNOVATION SWEDEN M105 R6 P24 LNA DOWN-LINK V6 DC DPX 10 P33 ALARM AUX1 W5 MS -20 dB P25 P29 DPX 16 15 P23 LNA UP-LINK TEST -30 dB 15 DC M->S S->M LED P22 P28 DOOR V1 P14 X0B 16 1 16 P13 16 P6 X0A 16 P12 P36 16 P11 GND TEST -30 dB MS -20 dB P35 PARKING FOR W 5 ANT ANT POWER SUPPLY UNIT RCU Figure 4-1 RCU in the WRH cabinet RCU for Radio Communication The RCU antenna for a radio modem is connected to the BS antenna via the uplink DC, provided the RCU and the WRH operate in the same cell system. Otherwise, the modem must have a separate antenna. Data is transferred between the WRH and the RCU via the P130 modem port on the RCI or FON. The RCU is also powered via the same port and has a battery with enough capacity to send a number of alarms if a main power failure occurs. RCU for Telephone Line Communication The land line version uses a telephone line connected to a terminal block on the RCU. A free strain relief bushing at the bottom of the WRH is used for the external telephone line cable. 4-8 044-05251 Rev A Chapter 5 Specifications Introduction This chapter provides specifications for the different WRH product line. Table 5-1 WRH Specifications Generic Dimensions (W x H x D in inches) 17.5 x 21 x 7 (low cover) 17.5 x 21 x 11 (high cover) Weight Empty low cover Cabinet with a low cover Cabinet with a high cover Equipped cabinet or high cover w/extra heat sink element 13 lbs (6.0 kg) 50 lbs (22.5 kg) 96lbs (44.0 kg) 41 lbs (18.5 kg) Temperature range -13 to +131°F (-25 to + 55°C) Casing class NEMA4/IP65 Fiber-Optic Link Budget 10dBo Amplifiers in 1 cabinet or 1 high cover Standard = 2 (WBA / PA combination) High Power = 1(WBA / MCPA combination) Receiver input port return loss 14dB Power supply voltage (default) 115 VAC Power consumption 160 W (standard WRH) 210 W typical, 250 W max (WRH-V) Fiber Optics (FON) Bandwidth @ 3dB 800 – 2200 MHz Power Consumption, total <5 W Wavelength TX: DFB 1310 or 1550 nm RX: 1250 – 1600 nm Transmitter Max continuous RF input Optical output power, two levels RF attenuation settable by SW in 1dB steps +36dBm +3 or 0dBm 0-20dB Receiver Max optic power input RF attenuation settable by SW in 1dB steps Alarm threshold level, settable warning Alarm threshold level, settable error +5dBm 4-24dB 0-40dBm 0-40dBm 044-05251 Rev A 5-1 Introduction Wideband Radio Head Standard WRH (SMR / iDEN 800 / 900 MHz) Frequency band UL 806-824 MHz; 896-901 MHz Frequency band DL 851-869 MHz; 935-940 MHz Max absolute delay <300 ns Gain adjustment range (in 1 dB steps) 30dB Gain (max variation –25 to +55 °C) <2dB Maximum input power (non-destructive) +13dBm Return Loss 14dB AGC for UL and DL ≥30dB Noise figure including fiber optic node 4dB Standard WRH (900 / 1800 / 2100 MHz) Frequency band UL 890-915 MHz; 1710-1785 Mhz; 1920-1980 MHz Frequency band DL 935-960 MHz; 1805-1880 MHz; 2110-2170 MHz Absolute group delay 5 µs Gain adjustment range (in 1 dB steps) 30dB Gain (max variation –25 to +55 °C) <2dB Noise figure UL at max gain 4dB WRH-V Frequency band UL 824-849 MHz; 1850-1910 MHz Frequency band DL 869-894 MHz; 1930-1990 MHz Max absolute delay <300 ns Gain adjustment range (in 1 dB steps) 30dB Gain Uplink Downlink Variation 35 to 60dB typical 45 to 70dB typical 3dB versus temperature and frequency including fiber link Instantaneous bandwidth 25 MHz Maximum input power (non-destructive) +13dBm Return Loss 11dB TX band IMD < -60dBc (1930-1990 MHz) Full power 8 EDGE carriers TX spurious in RX band < -111dBm / 200kHz Full power 8 EDGE carriers Output power +43dBm Noise figure excluding fiber optic link 4dB 5-2 044-05251 Rev A Appendix A Block Diagrams Introduction This appendix describes the main signals paths for the WRH. Standard WRH Figure A-1 illustrates a single band WRH block diagram. The TX signal from the BTS is converted to an optical signal at a FON within a BMU or OCM and fed to the WRH via a fiber optic cable. The FON in the WRH converts the fiber optic signal back to RF. It also supervises the signaling and reports errors via the RCU connected to the CU. The RF signal enters the WBA at P1101. Amplification occurs in the LNA and the additional amplifier stages followed by controllable attenuators. The signal exits the WBA on P1401 and enters the PA at P4 where it is amplified and fed to the DPX. If a BA is installed, the signal goes through it before being fed to the DPX, boosting the output DL signal from the PA by typically 6dB. The amplified output signal passes the DPX before it is fed to the service antenna. The uplink signal path is located on the same WBA but has no PA or BA stage. An optional LNA can be used. WBA PA BA 850 MHz TX0/RX0 DL DPX FOU To/From OCM or BMU DX WDM FON UL LNA WBA DX PA BA DL DPX RCU 1900 MHz TX0/RX0 UL LNA PSU RCI CU ALI To External alarms Figure A-1 Standard WRH Block Diagram 044-05251 Rev A A-1 WRH-V Wideband Radio Head WRH-V Non-Diversity Figure A-2 illustrates non-diversity block diagram configuration of the WRH-V. The WRH-V is always fed by a BTS via either a BMU or an OCM. The TX signal from the BTS is converted to an optical signal in a BMU or OCM and fed to the WRH-V via a fiber optic cable. The optical signal is received by the FON and converted to an RF signal. The FON supervises the signaling and reports errors via the RCU connected to the CU. The RF signal enters the WBA, is amplified, and further amplified in amplifier stages followed by controllable attenuators. The signal exits the WBA and enters the MCPA where it is amplified and fed to the DPX. The amplified output signal passes the DPX before it is fed to the service antenna. The uplink signal path is located on the same WBA but only has an LNA before entering the WBA. WBA MCPA 850 MHz TX0/RX0 DL DPX FOU To/From OCM or BMU DX WDM FON UL LNA WBA DX MCPA DL DPX RCU 1900 MHz TX0/RX0 UL LNA PSU RCI CU ALI To External alarms Figure A-2 WRH-V Block Diagram - Non-Diversity A-2 044-05251 Rev A Wideband Radio Head WRH-V Diversity Figure A-3 illustrates the diversity block diagram configuration of the WRH-V. With diversity installed, there are two paths on the UL instead of one. This requires an additional FON for the added receive path signal. Signal flow is identical to the non-diversity version with the MCPA on the DL and LNAs on the UL providing the additional amplification out of and into the WBA. WBA MCPA DL DPX 850 MHz TX0/RX0 FOU UL LNA FON 850 MHz RX1 UL DX DPX LNA WBA To/From OCM or BMU DX WDM FON MCPA DL DPX DX 1900 MHz TX0/RX0 UL LNA RCU UL LNA PSU 1900 MHz RX1 RCI CU DPX ALI To External alarms Figure A-3 WRH-V Block Diagram - Diversity 044-05251 Rev A A-3 WRH-V Wideband Radio Head This Page Intentionally Left Blank A-4 044-05251 Rev A Powerwave Installation and Service Manual Corporate Headquarters Powerwave Technologies, Inc. 1801 East St. Andrew Place Santa Ana, CA 92705 USA Tel: 714-466-1000 Fax: 714-466-5800 www.powerwave.com Main European Office Antennvägen 6 SE-187 80 Täby Sweden Tel: +46 8 540 822 00 Fax: +46 8 540 823 40 Main Asia-Pacific Office 23 F Tai Yau Building 181 Johnston Road Wanchai, Hong Kong Tel: +852 2512 6123 Fax: +852 2575 4860 ©Copyright March 2005, Powerwave Technologies, Inc. All Rights reserved. Powerwave, Powerwave Technologies, The Power in Wireless and the Powerwave logo are registered trademarks of Powerwave Technologies, Inc.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.3 Linearized : No Page Count : 55 Page Mode : UseOutlines XMP Toolkit : XMP toolkit 2.9.1-13, framework 1.6 About : uuid:bb90b285-0914-4af5-a32b-e0cd7f9d4e79 Producer : Acrobat Distiller 6.0.1 (Windows) Creator Tool : FrameMaker 7.2 Modify Date : 2007:04:13 13:02:07-07:00 Create Date : 2007:04:12 08:00:57Z Metadata Date : 2007:04:13 13:02:07-07:00 Document ID : uuid:867537cf-83f9-47c5-b878-bea27e1019c0 Format : application/pdf Title : 044-05251 WRH.book Creator : FrameMaker 7.2EXIF Metadata provided by EXIF.tools