Powerwave Technologies 5JS0120 Nexus Dual Band Repeater User Manual Nexus FT RMR indd

Powerwave Technologies Inc Nexus Dual Band Repeater Nexus FT RMR indd

Users Manual

Download: Powerwave Technologies 5JS0120 Nexus Dual Band Repeater User Manual Nexus FT RMR indd
Mirror Download [FCC.gov]Powerwave Technologies 5JS0120 Nexus Dual Band Repeater User Manual Nexus FT RMR indd
Document ID1330375
Application IDibyBABhTnDR7PDuqkhilYA==
Document DescriptionUsers Manual
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize134.47kB (1680932 bits)
Date Submitted2010-08-20 00:00:00
Date Available2011-01-16 00:00:00
Creation Date2008-09-03 15:40:03
Producing SoftwareAdobe PDF Library 8.0
Document Lastmod2010-08-20 16:04:58
Document TitleNexus_FT_RMR.indd
Document CreatorAdobe Illustrator CS3

COVERAGE SOLUTIONS
NEXUS FT RACK MOUNT RADIO
I N S T A L L AT I O N A N D S E R V I C E M A N U A L
0 4 4 - 0 5 3 2 6 R E V. B
J U LY 2 0 1 0
© 2010 Powerwave Technologies Incorporated. All rights reserved.
Powerwave Technologies and the Powerwave logo are registered trademarks.
Powerwave Technologies Inc. reserves the right to make changes to documentation and equipment, including but not limited to component substitution and circuitry changes. Changes that impact this document may be subsequently incorporated in a later revision
of this document.
This Powerwave product is designed to operate within the Normal Operating (typical operating) ranges or conditions specified in this
document. Operation of this equipment beyond the specified ranges in this document may cause (1) spurious emissions that violate
regulatory requirements; (2) the equipment to be automatically removed from service when maximum thresholds are exceeded; or
(3) the equipment to not perform in accordance with its specifications. It is the Operator's responsibility to ensure this equipment is
properly installed and operated within Powerwave operating specifications to obtain proper performance from the equipment and to
comply with regulatory requirements.
The rated output power of a Nexus FT is for multiple carriers. As long as the composite power does not exceed the rated power
(20W for North America), derating is not required for multiple carriers. For situations where regulatory requirements require reduced
interference to adjacent band users, the rating would have to be reduced by 3 dB. This power reduction is to be by means of input
power or gain reduction and not by an attenuator at the output of the device. Input power is rated at 115/230VAC, 50/60Hz, and
should be protected based on the power and fuse specifications in Chapter 5 of this manual. Power strips should, at a minimum,
conform to this requirement to prevent equipment damage and possible overload.
Federal Communications Commission (FCC)
This device complies with the technical standards governing mobile radio devices in accordance with FCC Rules. This device is
intended to facilitate the reception and transmission of mobile radio devices in the cellular, PCS or other mobile services, and its
operation by end users or others requires carrier consent under FCC rules. This equipment has been tested and found to comply
with the limits for a Class A digital device, pursuant to CRF47 part 15 of the FCC rules. This equipment is also certified to CRF47 part
22 (cellular), part 24 (PCS) and part 90 (iDEN800 and iDEN900) of the FCC Rules depending on the band of operation. Changes or
modifications not expressly approved by Powerwave Technologies, Inc. for compliance could void the user’s authority to operate this
equipment. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated
in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used
in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in
a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own
expense.
Industry Canada
The measured Canadian RF output power for the RH905022/13B is 46.3dBm.
European Requirements
The Powerwave Nexus FT apparatus introduced in EU markets are certified to ESTI EN 300 609-4 (GSM900 and DCS1800) and
ESTI EN 301 908-11 (WCDMA).
Powerwave Technologies Inc., 1801 East St. Andrew Place, CA 92705 Santa Ana, USA.
Phone +1 714 466 1000 – Fax +1 714 466 5800 – Internet www.powerwave.com
Revision Record
Revision Letter
Date of Change
Reason for Change
Rev A
September 2008
Initial release
Rev B
July 2010
Updated manual to show new FT RMR product
044-05326 Rev B
iii
Nexus FT RM RMR
This page intentionally left blank
iv
044-05326 Rev B
Nexus FT RM RMR
Table of Contents
TABLE OF CONTENTS
Warning, Cautions, and Notes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Safety . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Human Exposure to RF Radiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Repeater Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Installation and Maintenance of Antenna Systems . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . vii
Radiation Exposure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Electrostatic Discharge (ESD) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . viii
Chapter 1 - Product Description
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Scope of Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Cabinet Design . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rack Mount Radio module (RMR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
1-1
1-1
1-1
1-2
1-2
Chapter 2 - Indicators
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
Chapter 3 - Installation
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Site Survey . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Unpacking and Inspection . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
RMR Cabinet Location . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Rack Mounting the RMR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Downlink and Uplink . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Service and WLI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Main Power and Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Commissioning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Initial Startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3-1
3-1
3-1
3-1
3-1
3-2
3-2
3-3
3-4
3-5
3-5
Chapter 4 - Maintenance
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Clearing Alarm Faults . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Field Replaceable Units . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Fan Removal and Replacement . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
NetWay Manager (NWM) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Return For Service Procedures . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Obtaining an RMA . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Repackaging for Shipment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
4-1
4-1
4-1
4-1
4-5
4-5
4-6
4-6
4-6
4-6
Chapter 5 - Specifications
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
044-05326 Rev B
Table of Contents
Nexus FT RM RMR
List of Figures
1-1 Powerwave Nexus FT RM rack- fully equipped . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
1-2 Nexus FT Rack Mount Radio (RMR) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1-2
2-1 External Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 2-1
3-1 Downlink and Uplink Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
3-2 RMR Service and WLI Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
3-3 RMR Main Power and Grounding Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
4-1 Fan Assembly Screws . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
4-2 Fan Assembly . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
List of Tables
3-1
3-2
3-3
3-4
Downlink and Uplink Connection Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-2
RMR Service and WLI Connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-3
RMR Main Power and Grounding . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-4
Initial Status Procedure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3-5
4-1 Recommended Periodic Maintenance . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4-2 Alarm Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-1
4-3 Fan Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4-5
5-1 RMR Specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 5-1
vi
044-05326 Rev B
Preface
Warning, Cautions, and Notes
Warnings, Cautions, and Notes are found throughout this manual where applicable. The associated icons in
warnings and cautions are used to quickly identify a potential condition that could result in the consequences
described below if precautions are not taken. Notes clarify and provide additional information to assist the
user.
WARNING: The warning symbol means danger. You are in a situation that could cause bodily
injury or death. Before you work on any equipment, be aware of the hazards involved with electrical and RF circuitry and be familiar with standard practices for preventing accidents.
CAUTION: The caution symbol means the potential exists for equipment damage or loss of
data.
NOTE: Notes contain helpful suggestions or references to material not covered in the document.
Safety
Any personnel involved in installation, operation, or service of units included in a Powerwave repeater
system must understand and follow the points below:
❑ Powerwave Nexus FT Rack Mount Radios (RMR) are designed to receive and amplify signals from
one or more base stations and retransmit the signals to one or more mobile stations. They also act
the other way round, that is to receive signals from one or more mobile stations, then amplify and
retransmit the signals to the base stations. Powerwave Nexus FT RMR systems must be used
exclusively for this purpose and nothing else.
❑ Units supplied from the mains must be connected to grounded outlets and in conformity with the local
prescriptions.
❑ Power supply units supplied from the mains contain dangerous voltage that can cause electric shock.
Disconnect the mains prior to any work in such a unit. Local regulations are to be followed when
servicing such units. Only authorized service personnel are allowed to service units while the mains
are connected.
❑ All RF transmitting units, including Nexus FT RMRs, will generate radio signals and thereby give rise
to electromagnetic fields that may be hazardous to the health of any person who is extensively
exposed close to an antenna.
Human Exposure to RF Radiation
Safe distances must be kept when working around antennas. The following paragraphs describe the
cautions to be aware of during the installation and maintenance of antenna systems and how to calculate
safety distances needed for RF radiation at different antenna power and frequencies.
Repeater Antennas
To be able to receive and transmit signals, a repeater is connected to a donor antenna directed towards the
base station and a service antenna directed towards the coverage area. A fiber optic cable from the base
station might, however, be substituted for the donor antenna.
Installation and Maintenance of Antenna Systems
Installation and maintenance of all antenna systems must be performed with respect to the radiation
exposure limits for public areas. The antenna radiation level is affected by the output power, antenna gain,
and transmission devices such as cables, connectors, splitters and feeders. Also have in mind the system
minimum coupling loss, typically between 25 dB and 35 dB, is determined by a standard with the purpose
to protect base stations from noise and other performance dropping effects.
044-05326 Rev B
vii
Electrostatic Discharge (ESD)
Nexus FT RM RMR
Radiation Exposure
The World Health Organization (WHO) and International Commission on Non-Ionising Radiation Protection
(ICNIRP) have determined recommendations for radiation exposure. ICNIRP recommends not to exceed
the following radiation power for public exposure:
Frequency Radiation power
800/900 MHz
1800/1900 MHz
2100 MHz
4.5W/m²
9.0W/m²
10.0W/m²
For antennas larger than 20cm the maximum radiation power can be calculated by using the following
formula:
S= P/(4πr2)
S = Radiation power in W/m²
P = Output power in W
r = Distance between antenna and human in meters
Electrostatic Discharge (ESD)
ESD can severly damage essential parts of the equipment if not handled carefully. Parts on
Printed Circuit Board Assemblies (PCBA) as well as other parts in the equipment are
sensitive to ESD. Never touch the PCBA or uninsulated conductor surfaces unless
absolutely necessary.
If you must handle the PCBAs or uninsulated conductor surfaces, use ESD protective
equipment or first touch the chassis with your hand. Never let your clothes touch PCBAs or
uninsulated conductor surfaces and always store PCBAs in ESD-safe bags.
viii
044-05326 Rev B
Chapter 1
Product Description
Introduction
This manual contains information and procedures for installation, operation, and maintenance of the Rack
Mount Radio module as part of the Nexus FT Rack Mount Repeater. In this manual, the Nexus FT Rack Mount
Radio is referred to as the RMR. The manual is organized into chapters as follows:
❑
Chapter 1- Product Description
❑
Chapter 2- Indicators
❑
Chapter 3- Installation
❑
Chapter 4- Maintenance
❑
Chapter 5- Specifications
Scope of Manual
This manual is intended for use by service technicians familiar with similar types of equipment. It contains
required service information for the RMR and is current as of the printing date. Changes which occur after the
printing date may be incorporated by a complete manual revision or alternatively as additions.
Overview
The RMR is a repeater designed to be part of a Distributed Antenna System (DAS). The components are
mounted on a 19 in. rack and are intended for use in an indoor, temperature controlled environment.
As part of a DAS, the RMR extends coverage into uncovered areas in wireless mobile systems such as base
station fringe areas, tunnels, convention centers, airports, and buildings. It receives, amplifies, and transmits
signals to/from a Base Transceiver Station (BTS) and to/from Mobile Stations (MS).
The RMR unit is a dual wide band, bi-directional, RF amplifier with two separate donor ports and a common
(duplexed) service port per band. It connects to aFiber Base Distribution Unit (FBU) that combines, splits and
converts RF signals to an optical signal in the Uplink (UL) direction. In the Downlink (DL) direction, the FBU
converts optical signals to RF signals and splits the signal to RF outputs. Two separate full-duplex fibers handle
signal transport between the BTS Master Unit and the FBU. See the Fiber Base Unit Installation and Service
Manual (part number 044-05348) for more details. The DL signal and the UL signal combine onto one optical
fiber through a Wavelength Division Multiplexer (WDM). Wideband 4-way combiners handle RF splitting and
combining. The UL output signal is connected to the FBU via RF coax cable, converted to light, and sent via
fiber toward the BTS.
A Wireless Portal module distributes the DL/UL signals to/from the DAS.
The RMR is microprocessor controlled with alarm and operational status LEDs visible on the front. Cooling is
provided through forced air fans. Operational parameters are set using a PC running Powerwave OM-Online
software which communicates with the RMRs through the FBU or through a system solution. Remote operation
can be accomplished via Public Switched Telephone Network (PSTN) or a GSM net. The Operation and
Maintenance System (OMS) provides for Network Operations Center (NOC) configuration and alarm
monitoring.
044-05326 Rev B
1-1
Rack Mount Radio module (RMR)
Nexus FT RMR
Cabinet Design
The Nexus FT RMR modules are intended to be mounted in a 482 mm (19 in) cabinet at least 600 mm (23 in)
deep, similar to the one shown Figure 1-1.I
Typical RMR position
Figure 1-1 Powerwave Nexus FT RM rack- fully equipped
Rack Mount Radio module (RMR)
RMRs can handle multiple carriers over a wide band. The cabinet can be equipped with up to four RMRs.
Figure 1-2 Nexus FT Rack Mount Radio (RMR)
1-2
044-05326 Rev B
Chapter 2
Indicators
Introduction
This chapter contains descriptions of the controls, indicators, and connectors for the Nexus FT RMR.
Indicators
Red
Amber
Figure 2-1 External Indicators
The LEDs, shown in Figure 2-1, provide easy identification of a fault in the system. The amber operation LED
lights up approximately 15 seconds after the main power is switched on. When the LED is steady, the RMR is
ready for operation. The red alarm LED indicates a system error alarm when flashing and a critical alarm
when steady.
044-05326 Rev B
2-1
Indicators
Nexus FT RMR
This page intentionally left blank
2-2
044-05326 Rev B
Chapter 3
Installation
Introduction
This chapter contains unpacking, inspection, and installation instructions for installing and powering up the
Nexus FT RMR.
Site Survey
Powerwave recommends that a site survey be performed prior to equipment ordering or installation.
Performing a detailed site survey reduces or eliminates installation and turn-up delays. Pay particular
attention to power plant capacity, cooling needs, floor space, and RF/DC cabling/breaker requirements.
Cabinet dimensions and weights are listed in Chapter 5.
Unpacking and Inspection
This equipment has been operated, tested, and calibrated at the factory. Carefully open the container to
remove the equipment. Retain all packing material so it can be reassembled in the event the unit must be
returned to the factory. Perform the following steps:
❑ Visually inspect equipment for damage that may have occurred during shipment. If possible, in the
presence of the delivery person, if possible.
❑ Check for evidence of water damage, bent or warped chassis, loose screws or nuts, or extraneous
packing material in connectors.
If the equipment is damaged, file a claim with the carrier once the extent of the damage is assessed.
If the equipment must be returned to the factory, please contact the factory for a Return Material Authorization
(RMA). See Chapter 4.
RMR Cabinet Location
The RMR is designed for use in an indoor, temperature controlled environment mounted in a 19 inch cabinet.
Ensure the rear of the unit is supported properly.The RMR should be placed in an area that is free of
obstructions, easily accessible, and allows for proper air-flow and ventilation.
Rack Mounting the RMR
1.
2.
3.
4.
Set the RMR in the required position.
Align the mounting holes with the holes on the rack.
Insert the four mounting screws and tighten until secure.
Ensure the rear of the unit is supported properly.
044-05326 Rev B
3-1
Connections
Nexus FT RMR
Connections
Downlink and Uplink
RF and fiber cable connections should be verified both internally and externally before powering up the
equipment. Verify these connections with the as-built drawings and documents for your specific system
configuration. Table 3-1 and Figure 3-1 show the steps to connect the RMR module to the Nexus Fiber Base
Unit (FBU) at the head end.
Table 3-1 Connection Procedure
Step
Action
Connect a fiber cable between the RMR fiber terminal and a head end device, such as the FBU.
Connect an RF cable between the customer’s system and the Service 1 and Service 2 ports on the
RMR.
Service 1
Service 2
Fiber cable
Figure 3-1 RMR to FBU and Service 1/2 Connections
3-2
044-05326 Rev B
Nexus FT RMR
Connections
Main Power and Grounding
Local regulations need to be followed for the main power connection. Nexus FT RMRs are approved in
accordance with EN and UL/cUL regulations. This is, however, only valid if a classified power cord is used.
For the Nexus FT RMR to meet these regulations you must select one of the following classified and
approved cord types:
❑ EN – H 05 W5 - F HMR
❑ UL – AWM Style 2587
❑ CSA– AWM 1 A/B 11 A/B
WARNING: For Nexus FT RMRs supplied from the main power source, the main outlet must be
grounded.
Table 3-2 RMR Main Power and Grounding
Step
Action
Connect a power cable between the RMR and an appropriate power supply.
Connect a ground cable between the ground terminal on the RMR and an appropriate ground at the
installation site.
Power cable
Ground Cable
Figure 3-2 RMR Main Power and Grounding Connections
044-05326 Rev B
3-3
Commissioning
Nexus FT RMR
Commissioning
Before proceeding, carefully read the Safety section and check all connections made during the installation.
Ensure cables are properly tightened and not damaged.
The RMR can be configured locally with OM-Online by connecting a standard serial cable from the COM port
on the PC to the P31 PC port (RS-232) located on the front of the RMR. Details on using OM-Online are
described in the OM-Online User Manual - Connecting a PC for Local Access
Initial Startup
To complete the initial start-up of the Nexus FT RMR, follow the steps listed in Table 3-4.
Table 3-3 Initial Statup Procedure
Step
Action
Turn main power on.
Check the LEDs on the RMR. Refer to Figure 2-1 in Chapter 2 for correct power up indications.
NOTE: When optimizing RMRs, offset the UL gain 20 dB less than the DL gain as a starting point.
Always monitor the UL pass bands for noise levels and/or IMDs when optimizing and commissioning.
3-4
044-05326 Rev B
Chapter 4
Maintenance
Introduction
This chapter contains periodic maintenance and performance test procedures for the Nexus FT RMR.
Periodic Maintenance
Periodic maintenance requirements are listed in Table 4-1, as well as the intervals at which the tasks should
be performed.
Table 4-1 Recommended Periodic Maintenance
Task
Interval
Action
Inspection of cables
and connectors
12 months
Inspect power, RF, and Fiber cables for signs of damage or wear
(frayed insulation, cracks, punctures, etc.) Check connections to be
sure they are tight.
Clean cooling fans
12 months
Clean any dirt or debris that may potentially block air flow.
Optional
Perform cable sweeps.
Clean equipment
Clean as required depending on operating environment.
Troubleshooting
The sections that follow contain a list of problems that could occur and a few suggested actions that might
correct each problem. If the suggested corrective action does not eliminate the problem, please contact your
Powerwave field representative or help line for further instruction.
Clearing Alarm Faults
Table 4-2 lists the alarms that can be generated in the Nexus FT RMR. Critical, Error, and Warning alarms are
sent automatically from a Nexus FT RMR to OM-Online, stored and then viewed in the Alarm window.
Table 4-2 Alarm Troubleshooting
ID
Alarm Text
Power
044-05326 Rev B
Alarm Unit
PSM
Alarm
Description
Critical
PSM does not work properly. A sum signal from the PSM
indicates that at least one voltage output has dropped. If no mains
breakdown relay is used, then the alarm will also be sent at mains
breakdown
Ceasing
PSM. Ceasing is sent if the PSM works at start-up, and there is a
corresponding critical PSM alarm logged in the Events log. The
RMR will restart when the power is back and this alarm will be
sent
Ceasing
The cause of the alarm has ceased
4-1
Troubleshooting
Nexus FT RMR
Table 4-2 Alarm Troubleshooting (Continued)
ID
Alarm Text
RMR restart
Mains
breakdown
Alarm Unit
CU
External
Alarm
Description
None
Power on start, or user ordered reboot. Logged to indicate a
normal power up, or a restart ordered by the operator
Warning
Software error restart, 1st – 7th time. Restart 1st to 7th time during
a 14 day period. The counter is reset every 14th day, counted
from power up
Error
Software error restart 8th – 10th time. Restart 8th to 10th time
during the 14 day period. At the 11th time, the SW bank will be
blocked and not used anymore until a user ordered reset is
performed, or power is switched off/on
Critical
The mains power is gone. Used with an external relay indicating
mains breakdown. The external relay should be connected to
External Alarm 1 and the RMR configured to indicate this alarm. If
no relay is used, a mains breakdown will be reported as a PSM
fault
Ceasing
The mains power is back. Sent if there is a corresponding critical
mains breakdown alarm logged in the Events Log. The RMR will
restart when the power is back
Alarm reset
CU
None
Alarm reset by the user. All alarms are reset. The cause of the
alarm will be re-evaluated and reported, if still active
Local bus
error
WBA #,
MCPA#
Error
Error when communicating on the bus. The CU has no contact
with the WBA, or MCPA PCBA, which is taken out of service
Main bkd w
backup
External
Error
Used to indicate that the mains is no longer available. RMR is
powered by external battery backup unit. Suggested remedy:
Check the mains power
Ceasing
The cause of the alarm has ceased
Err in ADconverter
Warning
The analog-to-digital converter on the CU PCBA does not give
reliable values
New unit
detected
None
Compared to the last power on, the CU has recognized at least
one additional hardware unit
Inst. unit lost
Error
Compared to the last power on, the CU lacks at least one
hardware unit
10
EEPROM
error
Error
EEP read or write fail. Data cannot be written or read from the
EEPROM on the CU PCBA. User parameters are stored in the
EEPROM
11
Log memory
fault
Error
Log memory fault. Indicates that the log memory on the CU PCBA
is faulty. The RMR will not work. Not available in all CU software
versions
12
High temp
Warning
The CU PCBA temperature is higher than 90°C
Ceasing
The CU PCBA temperature has fallen below 90°C
CU
CU
13
REFO error
Error
Significant REFO drift or error detected by CU
14
Ext REFO
error
Warning
Suggested remedy: Check the reference source and the cables
4-2
044-05326 Rev B
Nexus FT RMR
Troubleshooting
Table 4-2 Alarm Troubleshooting (Continued)
ID
15
Alarm Text
CU battery
fault
Alarm Unit
CU
Alarm
Description
Warning
CU RAM battery fault. The battery for the RAM on the CU PCBA
has a voltage outside the normal 2.7 to 3.5 Volt. An alarm may be
initiated at start-up if the RMR has been stored out of power for a
long time. Suggested remedy: Ensure jumper P3 on the CU PCBA
is mounted to charge the battery
Ceasing
The cause of the alarm has ceased
16
SW load error
CU
Error
Software load error. An error has occurred during a software load
process. The flash memory does not contain a proper software.
Suggested remedy: Check the CU software using the OM-Online
SW Manager. Do NOT restart the RMR
17
Log cleared
CU
None
Log memory has been cleared. The check sum in the Events Log
memory is faulty. The log is cleared. Can be caused by a bad
RAM battery backup or low voltage to the RAM
18
RTC restarted
CU
None
The time is changed by the operator (logged to keep track of
changes made to the RTC)
Warning
Time reset to 1994-01-01. The RTC was unable to keep track of
the time and did a reset. Suggested remedy: Ensure jumper P3 on
the CU PCBA is mounted to charge the battery
Error
RTC does not operate. The CU has detected an error in the RTC
operation which makes the time unreliable. Suggested remedy:
Replace the CU PCBA
Config
The door has been open 30 seconds without disabling the alarm
Ceasing
The door has been closed 30 seconds, or the alarm is disabled
Config
External alarm input EA1 active more than 1 second
Ceasing
External alarm input EA1 no longer active
Config
External alarm input EA2 active more than 1 second
Ceasing
External alarm input EA2 no longer active
Config
External alarm input EA3 active more than 1 second
Ceasing
External alarm input EA3 no longer active
Config
External alarm input EA4 active more than 1 second
Ceasing
External alarm input EA4 no longer active
None
Invalid RMR password
Error
The backup battery on the RCU or the FON PCBA does not work
properly. Suggested remedy: Check cables or replace battery
Ceasing
The cause of the alarm has ceased
19
RTC error
20
Door open
alarm
21
22
23
24
External
alarm 1
External
alarm 2
Fan failure
alarm 3
Fan failure
alarm 4
34
Login failed
40
Battery fault
044-05326 Rev B
External
External
External
External
External
RCU, FON
charger
4-3
Troubleshooting
Nexus FT RMR
Table 4-2 Alarm Troubleshooting (Continued)
ID
42
48
Alarm Text
Antenna
isolation
Battery
backup fault
Alarm Unit
Alarm
WBA #,
Channel #,
UL/DL
Warning
Low antenna isolation. The antenna isolation is lower than the
gain set. Gain is reduced by 10dB – 13dB below the oscillation
point. Suggested remedy: Decrease gain or increase antenna
isolation
Error
Low antenna isolation at lowest gain. The gain has been reduced
as much as possible but the oscillation still remains. The amplifier
is turned off. Suggested remedy: Decrease gain or increase
antenna isolation
Ceasing
Normal operation again, that is no oscillation can be detected
13dB above the gain set
Error
If a battery backup unit alarm is connected to external alarm 2,
then the operator can configure the RMR to display this alarm
when the battery backup unit indicates alarm
Ceasing
The cause of the alarm has ceased
External
Description
70
Bad table
alarm
CU
Error
Requested table contains incorrect information (SW error)
71
Table not
found
CU
Error
Requested table not found in the database (SW or calibration
error)
72
Table
database
error
CU
Error
Table database not found (calibration error)
80
Antenna
SWR alarm
Donor
antenna
service
antenna
Error
Too low antenna return loss, caused either by cables, connectors,
or antenna problems.
90
245
4-4
FON power
alarm
Not In
Allowed Area
FON RF
CU
Suggested remedy: Check antenna and cables
Ceasing
The cause of the alarm has ceased
Error
A DC voltage on a FON PCBA is out of range. Suggested remedy:
Replace the FON PCBA.
Ceasing
The cause of the alarm has ceased
None
RMR is moved from the operating area and the RF HW is
switched on or off
044-05326 Rev B
Nexus FT RMR
Field Replaceable Units
Field Replaceable Units
The fan assembly is the only field replaceable unit. If any other components fail, please contact Powerwave
for service.
Fan Removal and Replacement
Refer to Table 4-3 and figures 4-1 and 4-2.
Table 4-3 Fan Removal
Step
Action
Disconnect power from the RMR.
Remove four retaining screws from the fan assembly housing. See Figure 4-1.
Remove the fan assembly and disconnect the plug. See Figure 4-2.
Install the new fan assembly in reverse order.
Remove these screws
Figure 4-1 Fan Assembly Screws
Figure 4-2 Fan Assembly
044-05326 Rev B
4-5
NetWay Manager (NWM)
Nexus FT RMR
NetWay Manager (NWM)
NWM is a Powerwave software package for network management. NWM can be used to access repeaters for
alarm reception, radio parameter configuration, software downloading, and scheduling activities.
Return For Service Procedures
When returning products to Powerwave, the following procedures will ensure optimum response.
Obtaining an RMA
A Return Material Authorization (RMA) number must be obtained prior to returning equipment to the factory
for service. Pease contact our Repair Department at +1-714-466-1000 to obtain this number, or FAX your
request to +1-714-466-5800. Failure to obtain this RMA number may result in delays in receiving repair
service.
Repackaging for Shipment
To ensure safe shipment of the unit, it is recommended that the original package designed for shipping the
unit be reused. If it is not available, contact Powerwave’s Customer Service Department at 1-800-797-9283,
+1-714-466-100 or by e-mail at support@pwav.com for packing material.
4-6
044-05326 Rev B
Chapter 5
Specifications
Introduction
This chapter provides specifications for the Nexus FT RMR.
Table 5-1: RMR Specifications
Electrical
Frequency band UL
824 to 849 MHz (Cellular)
806 to 824 MHz (800 iDEN)
896 to 902 MHz (900 iDEN)
1850 to 1910 MHz (PCS)
Frequency band DL
869 to 894 MHz (Cellular)
851 to 869 MHz (800 iDEN)
935 to 941 MHz (900 iDEN)
1930 to 1990 MHz (PCS)
Max absolute delay
<300 ns
Gain adjustment range (in 1 dB steps)
30 dB
Gain
Uplink
Downlink
Variation
*These are typical values and may vary due
to cable length.
35 to 60 dB typical - Excluding fiber link
45 to 70 dB typical - Excluding fiber link
Typically ± 1.5 dB versus temperature
± 2.0 dB versus DL frequency
± 0.5 dB versus DL output power
± 0.5 dB versus input voltage
± 2.0 dB versus UL frequency
Instantaneous bandwidth
25 MHz (Cellular)
18 MHz (800 iDEN)
5 MHz (900 iDEN)
60 MHz (PCS)
45 MHz (AWS)
Uplink AGC limit
0 dBm at FON input
Downlink AGC limit
43 dBm at antenna port
Return Loss
11 dB (Service Port), 14 dB (Donor Port)
Downlink, Spurious and Emissions level
-13 dBm/1 MHz (FCC)
Downlink power
+46.3 dBm RMS (20 Watts)
Noise figure excluding Uplink
4 dB
Power supply voltage
85 - 265VAC
Current Rating
.6A RMS
Maximum Current Draw (Dual Band)
6.5 A @115 VAC
3 A @ 230 VAC
044-05326 Rev B
5-1
Introduction
Nexus FT RMR
Table 5-1: RMR Specifications (Continued)
Recommend Fuse Size
10 - 20 A for AC Voltage
Power consumption
420 W typical, 600 W max
Impedance
Input
Output
Not Applicable
50 Ω
Mechanical
Dimensions (W x H x D in inches)
403 x 265.9 x 551 mm (15.9 x 10.5x 21.7 in)
Weight
< 30 kg (66 lbs)
Service Antenna port connector
Female N-Type
Donor Port Connector
SMA
Environmental
Operating Temperature Range
-0 °C to +55 °C (32°F to +131°F)
Altitude
-142 m to 4000 m (-466 ft. to 13100 ft.
Casing class
IP21
5-2
044-05326 Rev B


Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.3
Linearized                      : Yes
Encryption                      : Standard V2.3 (128-bit)
User Access                     : Print, Extract, Print high-res
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:08:04
Instance ID                     : uuid:c7f18730-da30-4e4f-a82c-d2973319238b
Document ID                     : adobe:docid:indd:f5dba9ce-7b1f-11dd-b866-a7900895c5f7
Rendition Class                 : proof:pdf
Derived From Instance ID        : f5dba9cd-7b1f-11dd-b866-a7900895c5f7
Derived From Document ID        : adobe:docid:indd:f5dba9c8-7b1f-11dd-b866-a7900895c5f7
Create Date                     : 2008:09:03 15:40:03-07:00
Modify Date                     : 2010:08:20 16:04:58-07:00
Metadata Date                   : 2010:08:20 16:04:58-07:00
Creator Tool                    : Adobe Illustrator CS3
Thumbnail Width                 : 256
Thumbnail Height                : 248
Thumbnail Format                : JPEG
Thumbnail Image                 : (Binary data 8712 bytes, use -b option to extract)
Format                          : application/pdf
Title                           : Nexus_FT_RMR.indd
Producer                        : Adobe PDF Library 8.0
Trapped                         : False
GTS PDFX Version                : PDF/X-1:2001
GTS PDFX Conformance            : PDF/X-1a:2001
N Pages                         : 1
Has Visible Transparency        : False
Has Visible Overprint           : False
Max Page Size W                 : 612.000000
Max Page Size H                 : 792.000000
Max Page Size Unit              : Points
Font Name                       : HelveticaNeueLTStd-BdEx, HelveticaNeueLTStd-Ex, HelveticaNeue-Extended
Font Family                     : Helvetica Neue LT Std, Helvetica Neue LT Std, HelveticaNeue Extended
Font Face                       : 73 Bold Extended, 53 Extended, Extended
Font Type                       : Open Type, Open Type, Unknown
Font Version                    : OTF 1.029;PS 001.000;Core 1.0.33;makeotf.lib1.4.1585, OTF 1.029;PS 001.000;Core 1.0.33;makeotf.lib1.4.1585, Version 2.037;PS 2.000;hotconv 1.0.51;makeotf.lib2.0.18671
Font Composite                  : False, False, False
Font File Name                  : HelveticaNeueLTStd-BdEx.otf, HelveticaNeueLTStd-Ex.otf, MyriadPro-Regular.otf
Plate Names                     : Cyan, Magenta, Yellow, Black, PANTONE 2748 CVC, PANTONE Cool Gray 10 CVC, PANTONE 2747 CVC
Swatch Group Name               : Default Swatch Group
Swatch Group Type               : 0
Swatch Colorant Swatch Name     : PANTONE 2747 CVC, PANTONE 2748 CVC, PANTONE Cool Gray 10 CVC
Swatch Colorant Type            : SPOT, SPOT, SPOT
Swatch Colorant Tint            : 100.000000, 100.000000, 100.000000
Swatch Colorant Mode            : CMYK, CMYK, CMYK
Swatch Colorant Cyan            : 100.000000, 100.000000, 0.000000
Swatch Colorant Magenta         : 78.999299, 75.999498, 0.000000
Swatch Colorant Yellow          : 0.000000, 0.000000, 0.000000
Swatch Colorant Black           : 8.999630, 17.999300, 72.000098
Page Count                      : 25
Creator                         : Adobe Illustrator CS3
EXIF Metadata provided by EXIF.tools
FCC ID Filing: E675JS0120

Navigation menu