Psion 7535OEM186 HANDHELD COMPUTER WITH RFID User Manual 8000007 Book

Psion Inc HANDHELD COMPUTER WITH RFID 8000007 Book

Contents

users manual 1

Download: Psion 7535OEM186 HANDHELD COMPUTER WITH RFID User Manual 8000007 Book
Mirror Download [FCC.gov]Psion 7535OEM186 HANDHELD COMPUTER WITH RFID User Manual 8000007 Book
Document ID421360
Application IDxX03rfJLf81xv7HMF0VqTw==
Document Descriptionusers manual 1
Short Term ConfidentialNo
Permanent ConfidentialNo
SupercedeNo
Document TypeUser Manual
Display FormatAdobe Acrobat PDF - pdf
Filesize162.68kB (2033533 bits)
Date Submitted2004-05-10 00:00:00
Date Available2004-05-10 00:00:00
Creation Date2004-05-10 10:47:24
Producing SoftwareAcrobat Distiller 4.0 for Macintosh
Document Lastmod2004-05-10 10:47:56
Document Title8000007 Book
Document CreatorFrameMaker 7.0
Document Author: Eva Szabo

7535-RFID Hand-Held
Computer
User Manual
December 10, 2003
ISO 9001 Certified
Quality Management System
Part No. 8000007.B
© Copyright 2003 by Psion Teklogix Inc., Mississauga, Ontario
This document and the information it contains is the property of Psion Teklogix Inc.,
is issued in strict confidence, and is not to be reproduced or copied, in whole or in
part, except for the sole purpose of promoting the sale of Teklogix manufactured
goods and services. Furthermore, this document is not to be used as a basis for
design, manufacture, or sub-contract, or in any manner detrimental to the interests
of Psion Teklogix Inc.
All trademarks are the property of their respective holders.
Return-To-Factory Warranty
Psion Teklogix warrants a return-to-factory warranty for a period of one year from
shipment. The warranty on Psion Teklogix manufactured equipment does not extend
to any product that has been tampered with, altered, or repaired by any person other
than an employee of an authorized Psion Teklogix service organization. See Psion
Teklogix terms and conditions of sale for full details.
Service
When requesting service, please provide information concerning the nature of the
failure and the manner in which the equipment was used when the failure occurred.
Type, model, and serial number should also be provided. Before returning any
products to the factory, call the Customer Services Group for a Return
Authorization number.
Support Services
Psion Teklogix provides a complete range of product support services to its customers. In North America, these services can be accessed through the Psion Teklogix
Helpdesk. The Helpdesk coordinates repairs and training, helps you to troubleshoot
problems over the phone and arranges for technicians or engineers to come to your
site. For contact information and a listing of worldwide offices, please refer to
Appendix A: Support Services And Worldwide Offices.
Disclaimer
Every effort has been made to make this material complete, accurate and up-to-date.
Teklogix Inc. reserves the right to make changes without notice and shall not be
held responsible for damages resulting from reliance on the material presented in
this manual.
PROGRAM LICENSE AGREEMENTS
Microsoft's End User License Agreement
You have acquired a device (“DEVICE”) that includes software licensed by Psion
Teklogix Inc. from Microsoft Licensing Inc. or its affiliates (‘MS”). Those installed
software products of MS origin, as well as associated media, printed materials, and
“online” or electronic documentation (“SOFTWARE”) are protected by international intellectual property laws and treaties. The SOFTWARE is licensed, not sold.
All rights reserved.
IF YOU DO NOT AGREE TO THIS END USER LICENSE AGREEMENT
(“EULA”), DO NOT USE THE DEVICE OR COPY THE SOFTWARE.
INSTEAD, PROMPTLY CONTACT PSION TEKLOGIX INC. FOR INSTRUCTIONS ON RETURN OF THE UNUSED DEVICE(S) FOR A REFUND. ANY
USE OF THE SOFTWARE, INCLUDING BUT NOT LIMITED TO USE ON
THE DEVICE, WILL CONSTITUTE YOUR AGREEMENT TO THIS EULA
(OR RATIFICATION OF ANY PREVIOUS CONSENT).
GRANT OF SOFTWARE LICENSE. This EULA grants you the following
license:
•
You may use the SOFTWARE only on the DEVICE.
•
NOT FAULT TOLERANT. THE SOFTWARE IS NOT FAULT TOLERANT. PSION TEKLOGIX INC. HAS INDEPENDENTLY DETERMINED HOW TO USE THE SOFTWARE IN THE DEVICE, AND MS
HAS RELIED UPON PSION TEKLOGIX INC. TO CONDUCT SUFFICIENT TESTING TO DETERMINE THAT THE SOFTWARE IS SUITABLE FOR SUCH USE.
•
NO WARRANTIES FOR THE SOFTWARE. THE SOFTWARE is provided “AS IS” and with all faults. THE ENTIRE RISK AS TO SATISFACTORY QUALITY, PERFORMANCE, ACCURACY, AND
EFFORT (INCLUDING LACK OF NEGLIGENCE) IS WITH YOU.
ALSO, THERE IS NO WARRANTY AGAINST INTERFERENCE
WITH YOUR ENJOYMENT OF THE SOFTWARE OR AGAINST
Psion Teklogix 7535 Hand-Held Computer User Manual
License Agreement
INFRINGEMENT. IF YOU HAVE RECEIVED ANY WARRANTIES
REGARDING THE DEVICE OR THE SOFTWARE, THOSE WARRANTIES DO NOT ORIGINATE FROM, AND ARE NOT BINDING ON, MS.
II
•
Note on Java Support. The SOFTWARE may contain support for programs written in Java. Java technology is not fault tolerant and is not
designed, manufactured, or intended for use or resale as online control
equipment in hazardous environments requiring fail-safe performance, such
as in the operation of nuclear facilities, aircraft navigation or communication systems, air traffic control, direct life support machines, or weapons
systems, in which the failure of Java technology could lead directly to
death, personal injury, or severe physical or environmental damage. Sun
Microsystems, Inc. has contractually obligated MS to make this disclaimer.
•
No Liability for Certain Damages. EXCEPT AS PROHIBITED BY
LAW, MS SHALL HAVE NO LIABILITY FOR ANY INDIRECT,
SPECIAL, CONSEQUENTIAL OR INCIDENTAL DAMAGES
ARISING FROM OR IN CONNECTION WITH THE USE OR PERFORMANCE OF THE SOFTWARE. THIS LIMITATION SHALL
APPLY EVEN IF ANY REMEDY FAILS OF ITS ESSENTIAL PURPOSE. IN NO EVENT SHALL MS BE LIABLE FOR ANY AMOUNT
IN EXCESS OF U.S. TWO HUNDRED FIFTY DOLLARS
(U.S.$250.OO).
•
Limitations on Reverse Engineering, Decompilation, and Disassembly.
You may not reverse engineer, decompile, or disassemble the SOFTWARE,
except and only to the extent that such activity is expressly permitted by
applicable law notwithstanding this limitation.
•
SOFTWARE TRANSFER ALLOWED BUT WITH RESTRICTIONS.
You may permanently transfer rights under this EULA only as part of a permanent sale or transfer of the Device, and only if the recipient agrees to this
EULA. If the SOFTWARE is an upgrade, any transfer must also include all
prior versions of the SOFTWARE.
•
EXPORT RESTRICTIONS. You acknowledge that SOFTWARE is
subject to U.S. export jurisdiction. You agree to comply with all applicable
international and national laws that apply to the SOFTWARE, including the
U.S. Export Administration Regulations, as well as end-user, end-use and
destination restrictions issued by U.S. and other governments. For additional information see http://www.microsoft.com/exporting/.
Psion Teklogix 7535 Hand-Held Computer User Manual
License Agreement
Meetinghouse Data Communications, Inc. End User License Agreement
End User License Agreement:
ATTENTION: PLEASE READ THIS SOFTWARE LICENSE AGREEMENT
("LICENSE") CAREFULLY BEFORE INSTALLATION. USE OF THE SOFTWARE IS SUBJECT TO THE SOFTWARE LICENSE TERMS SET FORTH
BELOW. USING THE SOFTWARE INDICATES YOUR ACCEPTANCE OF
THESE LICENSE TERMS. IF YOU DO NOT ACCEPT THESE LICENSE
TERMS, YOU MUST RETURN THE SOFTWARE FOR A FULL REFUND. IF
THE SOFTWARE IS SUPPLIED WITH ANOTHER PRODUCT, YOU MAY
RETURN THE ENTIRE UNUSED PRODUCT FOR A FULL REFUND.
Software License Terms:
The following terms govern your use of the enclosed Software unless you have a
separate written agreement with Meetinghouse Data Communications, Inc. herein
also known as “MDC”.
License Grant:
MDC grants you a non-exclusive and non-transferable license to Use one copy of
the Software. "Use" means storing, loading, installing, executing or displaying the
Software. “Software” means software, documentation and any fonts accompanying
this License whether on disk, in read only memory, on any other media or in any
other form. You may not modify the Software or disable any licensing or control
features of the Software. If the Software is licensed for "concurrent use", you may
not allow more than the maximum number of authorized users to Use the Software
concurrently.
The Software is licensed as a "Shareware" version, on one computer only. You may
use the Software distributed and licensed as Shareware on a trial basis only. The
shareware version of the Software may be distributed freely without any associated
fees to other parties who wish to try the software as long as the Software is distributed within an exact copy of the original MDC self-extracting installation file. In
other words, nothing may be left out of the Shareware as distributed on MDC's web
site at http://www.mtghouse.com.
Psion Teklogix 7535 Hand-Held Computer User Manual
III
License Agreement
All permanent licenses are prepaid and the Software is licensed to you by MDC.
You own the media on which the Software is recorded but MDC and/or MDC’s
licensor(s) retain title to the Software. The Software and any copies which this
License authorizes you to make are subject to this License.
Permitted Uses and Restrictions:
This License allows you to install and use the Software on a single computer at a
time. This License does not allow the Software to exist on more than one computer
at a time. You may make one copy of the Software in machine-readable form for
backup purposes only. The backup copy must include all copyright information contained on the original. Except as expressly permitted in this License, you may not, in
whole or part, decompile, reverse engineer, disassemble, modify, rent, lease, loan,
sublicense, distribute or create derivative works based upon the Software, or transmit the Software over a network. You may not copy the Software onto any bulletin
board or similar system. You agree that you will not utilize any information obtained
from MDC or obtained or learned in the course of using the Software, to develop or
improve technology with similar functionality to the Software, nor will you directly
or indirectly assist any other party in doing so. You further agree that you will not
separate the various modules of the software for their different purposes, if any.
High Risk Activities:
The Software is not fault-tolerant and is not designed, manufactured or intended for
use or resale as on-line control equipment in hazardous environments requiring failsafe performance, such as in the operation of nuclear facilities, aircraft navigation or
communication systems, air traffic control, direct life support machines, or weapons
systems, in which the failure of the Software could lead directly to death, personal
injury, or severe physical or environmental damage ("High Risk Activities").
Accordingly, MDC and its suppliers specifically disclaim any express or implied
warranty of fitness for High Risk Activities. You agree that MDC and its suppliers
will not be liable for any claims or damages arising from the use of the Software in
such applications.
Ownership:
The Software is licensed, not sold. The Software is owned and copyrighted by MDC
or its third party suppliers. Your license confers no title or ownership in the Software
and is not a sale of any rights in the Software. You acknowledge such ownership and
intellectual property rights and will not take any action to jeopardize, limit or interfere in any manner with MDC's or its suppliers' ownership of or rights with respect
IV
Psion Teklogix 7535 Hand-Held Computer User Manual
License Agreement
to the Software. The Software is protected by copyright and other intellectual property laws and by international treaties. MDC's third party suppliers may protect their
rights in the event of any violation of these License Terms.
Termination:
Your rights under this License will terminate automatically without notice from
MDC if you fail to comply with any term(s) of this License. Upon termination, you
must immediately destroy the Software, together with all copies, adaptations and
merged portions in any form.
U.S. Government Restricted Rights:
The Software and documentation have been developed entirely at private expense
and are provided as "Commercial Computer Software" or "restricted computer software". They are delivered and licensed as "commercial computer software" as
defined in DFARS 252.227-7013 (Oct 1988), DFARS 252.211-7015 (May 1991) or
DFARS 252.227-7014 (Jun 1995), as a "commercial item" as defined in FAR 2.101
(a), or as "Restricted computer software" as defined in FAR 52.227-19 (Jun 1987)
(or any equivalent agency regulation or contract clause), whichever is applicable.
You have only those rights provided for such Software and Documentation by the
applicable FAR or DFARS clause or the MDC standard software agreement for the
product.
Export Law Assurances:
You may not use or otherwise export or reexport the Software except as authorized
by United States law and the laws of the jurisdiction in which the Software was
obtained. In particular, but without limitation, the Software may not be exported or
reexported (i) into (or to a national or resident of) any U.S. embargoed country or
(ii) to anyone on the U.S. Treasury Department's list of Specially Designated
Nationals or the U.S. Department of Commerce's Table of Denial Orders. By using
the Software, you represent and warrant that you are not located in, under control of,
or a national or resident of any such country or on any such list.
Limited Warranty on Media: (if applicable)
MDC warrants the media on which the Software is recorded to be free from defects
in materials and workmanship under normal use for a period of ninety (90) days
from the date of original retail purchase. Your exclusive remedy under this paragraph shall be, at MDC's option, a refund of the purchase price of the product containing the Software or replacement of the Software which is returned to MDC or a
Psion Teklogix 7535 Hand-Held Computer User Manual
License Agreement
MDC authorized representative with a copy of the receipt. THIS LIMITED WARRANTY AND ANY IMPLIED WARRANTIES ON THE MEDIA INCLUDING
THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
A PARTICULAR PURPOSE ARE LIMITED IN DURATION TO NINETY (90)
DAYS FROM THE DATE OF ORIGINAL RETAIL PURCHASE. SOME JURISDICTIONS DO NOT ALLOW LIMITATIONS ON HOW LONG AN IMPLIED
WARRANTY LASTS, SO THIS LIMITATION MAY NOT APPLY TO YOU. THE
LIMITED WARRANTY SET FORTH HEREIN IS EXCLUSIVE AND IN LIEU
OF ALL OTHERS, WHETHER ORAL OR WRITTEN, EXPRESS OR IMPLIED.
LICENSOR SPECIFICALLY DISCLAIMS ALL OTHER WARRANTIES. THIS
LIMITED WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU
MAY ALSO HAVE OTHER RIGHTS WHICH VARY BY JURISDICTION.
Disclaimer of Warranty on Software:
You expressly acknowledge and agree that use of the Software is at your sole risk.
The Software is provided "AS IS" and without warranty of any kind and MDC and
MDC’s licensor(s) (for the purposes of warranty and liability, MDC and MDC's
licensor(s) shall be collectively referred to as "MDC") EXPRESSLY DISCLAIM
ALL WARRANTIES AND/OR CONDITIONS, EXPRESS OR IMPLIED,
INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES
AND/OR CONDITIONS OF MERCHANTABILITY OR SATISFACTORY
QUALITY AND FITNESS FOR A PARTICULAR PURPOSE AND NONINFRINGEMENT OF THIRD PARTY RIGHTS. LICENSOR DOES NOT WARRANT THAT THE FUNCTIONS CONTAINED IN THE SOFTWARE WILL
MEET YOUR REQUIREMENTS, OR THAT THE OPERATION OF THE SOFTWARE WILL BE UNINTERRUPTED OR ERROR-FREE, OR THAT DEFECTS
IN THE SOFTWARE WILL BE CORRECTED. FURTHERMORE, LICENSOR
DOES NOT WARRANT OR MAKE ANY REPRESENTATIONS REGARDING
THE USE OR THE RESULTS OF THE USE OF THE SOFTWARE OR
RELATED DOCUMENTATION IN TERMS OF THEIR CORRECTNESS,
ACCURACY, RELIABILITY, OR OTHERWISE. NO ORAL OR WRITTEN
INFORMATION OR ADVICE GIVEN BY LICENSOR OR AN LICENSOR
AUTHORIZED REPRESENTATIVE SHALL CREATE A WARRANTY OR IN
ANY WAY INCREASE THE SCOPE OF THIS WARRANTY. SHOULD THE
SOFTWARE PROVE DEFECTIVE, YOU (AND NOT LICENSOR OR AN
LICENSOR AUTHORIZED REPRESENTATIVE) ASSUME THE ENTIRE
COST OF ALL NECESSARY SERVICING, REPAIR OR CORRECTION. SOME
JURISDICTIONS DO NOT ALLOW THE EXCLUSION OF IMPLIED WAR-
VI
Psion Teklogix 7535 Hand-Held Computer User Manual
License Agreement
RANTIES, SO THE ABOVE EXCLUSION MAY NOT APPLY TO YOU. THE
TERMS OF THIS DISCLAIMER DO NOT AFFECT OR PREJUDICE THE
STATUTORY RIGHTS OF A CONSUMER ACQUIRING LICENSOR PRODUCTS OTHERWISE THAN IN THE COURSE OF A BUSINESS, NEITHER DO
THEY LIMIT OR EXCLUDE ANY LIABILITY FOR DEATH OR PERSONAL
INJURY CAUSED BY LICENSOR’S NEGLIGENCE.
Limitation of Liability:
UNDER NO CIRCUMSTANCES, EXCEPT TO THE EXTENT PROHIBITED
BY LOCAL LAW, INCLUDING NEGLIGENCE, SHALL LICENSOR, ITS SUBSIDIARIES, AFFILIATES, OR SUPPLIERS BE LIABLE FOR ANY DIRECT,
INCIDENTAL, SPECIAL, INDIRECT OR CONSEQUENTIAL DAMAGES
(INCLUDING LOST PROFIT, LOST DATA, OR DOWNTIME COSTS) ARISING OUT OF OR RELATING TO THIS LICENSE, THE USE, INABILITY TO
USE, OR THE RESULTS OF USE OF THE SOFTWARE, WHETHER BASED IN
WARRANTY, CONTRACT, TORT OR OTHER LEGAL THEORY, AND
WHETHER OR NOT ADVISED OF THE POSSIBILITY OF SUCH DAMAGES.
In no event shall MDC's total liability to you for all damages exceed the price paid
for the license to use the Software, regardless of the form of the claim.
Government End Users:
If the Software is supplied to the United States Government, the Software is classified as "restricted computer software" as defined in clause 52.227-19 of the FAR.
The United States Government's rights to the Software are as provided in clause
52.227-19 of the FAR.
Controlling Law and Severability:
This License shall be governed by the laws of the United States and the State of
New Hampshire. As to any dispute relating to this License or the Software, you further agree to jurisdiction and venue in the Federal and State Courts located in the
State of New Hampshire. If for any reason a court of competent jurisdiction finds
any provision, or portion thereof, to be unenforceable, the remainder of this License
shall continue in full force and effect.
Acknowledgement:
Your use of any software produced by MDC is based only on your acknowledgement that you have read this License, understand it, and agree to be bound by its
terms and conditions.
Psion Teklogix 7535 Hand-Held Computer User Manual
VII
License Agreement
MDC Acknowledgments:
This product includes software developed by MDC and its licensors. This product
includes software developed by the OpenSSL Project for use in the OpenSSL Toolkit (http://www.openssl.org/)". This product includes cryptographic software written
by Eric Young (eay@cryptsoft.com). This product includes software written by Tim
Hudson (tjh@cryptsoft.com).
Complete Agreement:
This License constitutes the entire agreement between the parties with respect to the
use of the Software and supersedes all prior or contemporaneous understandings
regarding such subject matter. No amendment to or modification of this License will
be binding unless in writing and signed by MDC.
NOTE: EXCEPT TO THE EXTENT ALLOWED BY LOCAL LAW, THESE
WARRANTY TERMS DO NOT EXCLUDE, RESTRICT, OR MODIFY, AND
ARE IN ADDITION TO, THE MANDATORY STATUTORY RIGHTS APPLICABLE TO THE LICENSE OF THE SOFTWARE TO YOU.
Meetinghouse Data Communications, Inc.
150 Greenleaf Avenue, Unit F
Portsmouth, NH 03801
Revised 8/12/2002
VIII
Psion Teklogix 7535 Hand-Held Computer User Manual
TABLE
OF CONTENTS
Program License Agreements . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . I
Approvals And Safety Summary . . . . . . . . . . . . . . . . . . . . . . . . . . .xiii
Chapter 1: Introduction
1.1
1.2
1.3
About This Manual . . . . . . . . . . .
Text Conventions . . . . . . . . . . . .
About The 7535 Hand-Held Computer .
1.3.1 Features. . . . . . . . . . . . . .
1.3.2 The 7535 Hand-Held Computer .
1.3.3 Regulatory Labels . . . . . . . .
Preparing The 7535 For Operation . . . . . . . . . . . . .
2.1.1 Equipment You Need To Get Started . . . . . . . .
2.1.2 Charging The Battery . . . . . . . . . . . . . . . .
2.1.3 Attaching Carrying Accessories . . . . . . . . . . .
2.1.3.1 Attaching The Hand Strap . . . . . . . . .
2.1.3.2 Attaching The Pistol Grip . . . . . . . . .
Powering Up The 7535 And Configuring The Radio . . . .
2.2.1 Installing The Battery And Switching The 7535 On.
.13
.13
.13
.13
.14
.15
.16
.17
2.2.3 Assigning An IP Address . . . . . . . . . . .
2.2.4 Name Servers Tab . . . . . . . . . . . . . . .
2.2.5 Advanced Features . . . . . . . . . . . . . . .
2.2.5.1 Rearranging Preferred Networks . .
2.2.5.2 Deleting A Preferred Network . . . .
2.2.5.3 Changing Network Properties . . . .
Checking The Scanner . . . . . . . . . . . . . . . .
Using Microsoft® ActiveSync® To Work With Files.
.24
.25
.26
.26
.27
.27
.27
.27
Chapter 2: Basic Checkout
2.1
2.2
2.3
2.4
Psion Teklogix 7535 Hand-Held Computer User Manual
Contents
2.5
2.6
Calibrating The Touchscreen . . . . . . . . . . . . . . . . . . . . . . 28
Resetting The 7535 Hand-Held . . . . . . . . . . . . . . . . . . . . . 28
Chapter 3: Getting To Know Your 7535
3.1
3.2
3.3
3.4
3.5
3.6
3.7
ii
Features Of The 7535 . . . . . . . . . . . . . . . . . . . . . . .
The Battery. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.1 Battery Safety . . . . . . . . . . . . . . . . . . . . . . . .
3.2.2 Removing And Installing The Battery Pack . . . . . . . .
3.2.3 Charging The Battery . . . . . . . . . . . . . . . . . . . .
Switching The 7535 Hand-Held On And Off . . . . . . . . . . .
The Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.1 Modifier Keys. . . . . . . . . . . . . . . . . . . . . . . .
3.4.1.1 Activating Modifier Keys. . . . . . . . . . . . .
3.4.1.2 Locking Modifier Keys. . . . . . . . . . . . . .
3.4.2 The Keys . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3 The 58-Key Keyboard . . . . . . . . . . . . . . . . . . .
3.4.4 The 36-Key Keyboard . . . . . . . . . . . . . . . . . . .
3.4.5 The Keypad Backlight . . . . . . . . . . . . . . . . . . .
The Display . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1 Adjusting The Display Backlight . . . . . . . . . . . . . .
3.5.2 Adjusting The Contrast . . . . . . . . . . . . . . . . . . .
3.5.3 Calibrating The Touchscreen . . . . . . . . . . . . . . . .
7535 Indicators. . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.1 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.1.1 Charge LED . . . . . . . . . . . . . . . . . . .
3.6.1.2 Radio Traffic LED . . . . . . . . . . . . . . . .
3.6.1.3 Scan LED. . . . . . . . . . . . . . . . . . . . .
3.6.1.4 User Application LED . . . . . . . . . . . . . .
3.6.2 Onscreen Indicators . . . . . . . . . . . . . . . . . . . . .
3.6.3 Audio Indicators . . . . . . . . . . . . . . . . . . . . . .
3.6.3.1 Adjusting The Beeper Volume . . . . . . . . . .
Internal Scanners. . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.1 Scanning Techniques . . . . . . . . . . . . . . . . . . . .
3.7.2 Scan LED Indicators . . . . . . . . . . . . . . . . . . . .
3.7.3 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . .
3.7.4 Operating One Dimensional (1D) Internal Laser Scanners.
3.7.5 Operating Internal PDF Laser Scanners . . . . . . . . . .
Psion Teklogix 7535 Hand-Held Computer User Manual
31
32
32
32
33
34
35
35
36
36
36
37
38
40
40
40
41
41
42
42
43
44
44
44
45
47
48
48
49
49
50
50
51
Contents
3.7.6 Operating Internal Two Dimensional (2D) Imager Scanners
Connecting & Disconnecting Tethered Peripherals . . . . . . . . .
Monitoring The Battery And Maximizing Run Time . . . . . . . .
3.9.1 Storing Batteries . . . . . . . . . . . . . . . . . . . . . . .
3.10 Monitoring The Network Connection. . . . . . . . . . . . . . . .
3.11 Uploading Data In A Docking Station . . . . . . . . . . . . . . .
3.12 General Maintenance . . . . . . . . . . . . . . . . . . . . . . . .
3.12.1 Caring For The Touchscreen . . . . . . . . . . . . . . . . .
3.12.2 Cleaning The 7535 . . . . . . . . . . . . . . . . . . . . . .
3.8
3.9
.51
.52
.53
.55
.55
.56
.56
.56
.57
.61
.61
.62
.63
.64
.65
.66
.66
.67
.68
.68
.69
.70
.71
.71
.71
.72
.73
.74
.75
.76
Chapter 4: Working With Windows CE
4.1
4.2
4.3
4.4
4.5
Navigating In Windows CE And Applications . . . .
4.1.1 Navigating Using A Touchscreen And Stylus .
4.1.2 Navigating Using The Keyboard. . . . . . . .
Working With Files, Folders And Programs . . . . .
The Startup Desktop. . . . . . . . . . . . . . . . . .
4.3.1 The Desktop Icons . . . . . . . . . . . . . . .
4.3.2 The Taskbar . . . . . . . . . . . . . . . . . .
4.3.2.1 Using The Taskbar . . . . . . . . . .
4.3.2.2 Customizing The Taskbar . . . . . .
The Start Menu . . . . . . . . . . . . . . . . . . . .
4.4.1 The Desktop . . . . . . . . . . . . . . . . . .
4.4.2 Security Settings . . . . . . . . . . . . . . . .
4.4.3 The System Tray . . . . . . . . . . . . . . . .
4.4.4 The Task Manager . . . . . . . . . . . . . . .
4.4.5 Cycle Tasks. . . . . . . . . . . . . . . . . . .
4.4.6 Power Info . . . . . . . . . . . . . . . . . . .
4.4.7 Programs . . . . . . . . . . . . . . . . . . . .
4.4.8 Settings . . . . . . . . . . . . . . . . . . . . .
4.4.9 Run . . . . . . . . . . . . . . . . . . . . . . .
4.4.10 Shutdown . . . . . . . . . . . . . . . . . . . .
Using A Dialogue Box . . . . . . . . . . . . . . . .
Chapter 5: Configuration
5.1
5.2
Remote Desktop Connection . . . . . . . . . . . . . . . . . . . . . . .83
Pocket PC Compatibility . . . . . . . . . . . . . . . . . . . . . . . . .83
Psion Teklogix 7535 Hand-Held Computer User Manual
iii
Contents
iv
5.3
5.4
5.5
The Control Panel . . . . . . . . . . . . . . . .
Control Panel Icons . . . . . . . . . . . . . . .
Basic Setup. . . . . . . . . . . . . . . . . . . .
5.5.1 Display Properties. . . . . . . . . . . . .
5.5.1.1 Display Contrast . . . . . . . .
5.5.1.2 Display Backlight . . . . . . .
5.5.1.3 Display Appearance . . . . . .
5.5.2 Keyboard Properties . . . . . . . . . . .
5.5.2.1 Key Repeat . . . . . . . . . . .
5.5.2.2 Keyboard Backlight . . . . . .
5.5.2.3 Keyboard One Shot Modes. . .
5.5.2.4 Keyboard Macro Keys . . . . .
5.5.2.5 Unicode Mapping . . . . . . .
5.5.3 Volume And Sound Properties . . . . . .
5.5.3.1 Volume Adjustments . . . . . .
5.5.4 Power Management Properties . . . . . .
5.5.4.1 Battery Capacity . . . . . . . .
5.5.4.2 Power Saving Schemes. . . . .
5.5.4.3 Suspend Threshold . . . . . . .
5.5.4.4 Charger Details . . . . . . . . .
5.5.5 Stylus Properties . . . . . . . . . . . . .
5.5.5.1 Setting Double-Tap Sensitivity .
5.5.5.2 Touchscreen Calibration . . . .
5.5.6 Certificate Assignment . . . . . . . . . .
. 83
. 84
. 88
. 88
. 88
. 89
. 91
. 92
. 92
. 93
. 94
. 95
. 97
. 99
. 99
.100
.100
.101
.102
.103
.103
.104
.104
.105
5.7
Scanner Properties Setup . . . . . . . .
5.7.1 Scanner Options. . . . . . . . . .
5.7.2 Bar Codes . . . . . . . . . . . . .
5.7.2.1 Code 39 Settings . . . .
5.7.2.2 Code 128 Settings . . .
5.7.2.3 EAN 13 Settings . . . .
5.7.2.4 EAN 8 . . . . . . . . .
5.7.2.5 UPC And EAN Settings
5.7.2.6 UPC A Settings . . . . .
5.7.2.7 UPC E Settings . . . . .
5.7.2.8 Codabar. . . . . . . . .
5.7.2.9 Code 93 . . . . . . . . .
5.7.2.10 Code 11 . . . . . . . . .
.118
.118
.121
.122
.124
.125
.126
.127
.127
.127
.128
.128
.128
Psion Teklogix 7535 Hand-Held Computer User Manual
Contents
5.8
5.7.2.11 Interleaved 2 of 5 . . . . . . . . . . .
5.7.2.12 MSI Plessey . . . . . . . . . . . . . .
5.7.2.13 Discrete 2 of 5 . . . . . . . . . . . . .
5.7.2.14 IATA 2 of 5 . . . . . . . . . . . . . .
5.7.2.15 Postal: Australian . . . . . . . . . . .
5.7.2.16 Postal: Japanese . . . . . . . . . . . .
5.7.2.17 Postal: Korean . . . . . . . . . . . . .
5.7.2.18 Postal: PlaNET. . . . . . . . . . . . .
5.7.2.19 Postal: PostNET . . . . . . . . . . . .
5.7.2.20 Postal: Royal Mail . . . . . . . . . . .
5.7.2.21 2D DataMatrix . . . . . . . . . . . . .
5.7.2.22 2D Maxicode. . . . . . . . . . . . . .
5.7.2.23 2D PDF-417 . . . . . . . . . . . . . .
5.7.2.24 2D Micro PDF-417 . . . . . . . . . .
5.7.2.25 2D QR Code . . . . . . . . . . . . . .
5.7.2.26 2D RSS Code . . . . . . . . . . . . .
5.7.2.27 Aztec . . . . . . . . . . . . . . . . . .
5.7.3 Translations . . . . . . . . . . . . . . . . . . .
SNMP (Simple Network Management Protocol) Setup
5.8.1 Contact Tab. . . . . . . . . . . . . . . . . . . .
5.8.2 Communities Tab . . . . . . . . . . . . . . . .
5.8.2.1 Adding A Community . . . . . . . . .
5.8.2.2 Modifying A Community Setting . . .
5.8.2.3 Removing An Existing Community . .
5.8.3 Trap Destination Tab . . . . . . . . . . . . . . .
5.8.3.1 Enabling Authentication TRAPS . . .
5.8.3.2 Adding A Destination . . . . . . . . .
5.8.3.3 Changing A Destination . . . . . . . .
5.8.3.4 Removing A Trap Destination . . . . .
5.8.4 Permitted Hosts Tab . . . . . . . . . . . . . . .
5.8.4.1 Adding A Host . . . . . . . . . . . . .
5.8.4.2 Changing A Host. . . . . . . . . . . .
129
129
129
130
130
130
130
131
131
131
131
131
131
132
132
132
132
132
134
135
136
137
138
138
139
139
139
140
140
141
141
142
147
147
147
147
148
149
Chapter 6: Tekterm Application
6.1
6.2
The Tekterm Application . . . . . . . .
Additional Keyboard Functions . . . . .
6.2.1 Function Keys And Softkeys. . .
6.2.1.1 Function Keys . . . . .
6.2.1.2 Softkey Function Keys.
6.2.2 Macro Keys. . . . . . . . . . . .
Psion Teklogix 7535 Hand-Held Computer User Manual
Contents
6.3
6.4
6.5
6.6
6.8
6.9
vi
Keyboard Modes . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.1 View Mode . . . . . . . . . . . . . . . . . . . . . . . . . .
6.3.1.1 Changing Font Sizes . . . . . . . . . . . . . . . .
6.3.1.2 Panning The Screen Contents . . . . . . . . . . .
6.3.1.3 Exiting View Mode . . . . . . . . . . . . . . . . .
6.3.2 Using The Task Manager To Switch Between Applications .
The Tekterm Status Area. . . . . . . . . . . . . . . . . . . . . . .
TESS Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.2 Working With Multiple Sessions . . . . . . . . . . . . . . .
6.5.3 The Field Types. . . . . . . . . . . . . . . . . . . . . . . .
6.5.4 IBM 5250 Emulation Keys . . . . . . . . . . . . . . . . . .
6.5.5 Data Entry. . . . . . . . . . . . . . . . . . . . . . . . . . .
6.5.5.1 TESS Edit Modes And Cursor Movement . . . . .
6.5.5.2  Key Behaviour In TESS . . . . . . . . . .
6.5.5.3  Key Behaviour In TESS . . . . . . . . .
6.5.6 TESS Status Message . . . . . . . . . . . . . . . . . . . . .
6.5.7 Lock Messages . . . . . . . . . . . . . . . . . . . . . . . .
6.5.8 Control Commands . . . . . . . . . . . . . . . . . . . . . .
6.5.9 Resetting A TESS Session . . . . . . . . . . . . . . . . . .
6.5.10 The Local Menu . . . . . . . . . . . . . . . . . . . . . . .
6.5.11 Selecting Another Host Computer . . . . . . . . . . . . . .
6.5.12 Queuing Mode . . . . . . . . . . . . . . . . . . . . . . . .
ANSI Emulation . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.6.1 Configuration . . . . . . . . . . . . . . . . . . . . . . . . .
6.6.2 Sending Data To The Host . . . . . . . . . . . . . . . . . .
6.6.3 Psion Teklogix Keyboard And VT220 Equivalent Keys . . .
6.6.4 Block Mode (Local Editing) . . . . . . . . . . . . . . . . .
6.6.5 Working With Sessions . . . . . . . . . . . . . . . . . . . .
6.6.5.1 Establishing A New Session . . . . . . . . . . . .
6.6.5.2 Listing Sessions And Moving To Other Sessions .
6.6.5.3 Closing A Session . . . . . . . . . . . . . . . . .
6.6.5.4 Printing A Screen . . . . . . . . . . . . . . . . . .
6.6.5.5 Smart Echo – Disabling . . . . . . . . . . . . . .
.150
.150
.150
.150
.151
.152
.153
.154
.154
.154
.154
.155
.155
.156
.157
.158
.159
.160
.160
.160
.161
.161
.162
.162
.162
.163
.163
.164
.165
.165
.165
.165
.166
.166
The Tekterm Startup Display Menu . . . . . . . . . . . . . . . . . . .168
Working With Menus . . . . . . . . . . . . . . . . . . . . . . . . . .169
Psion Teklogix 7535 Hand-Held Computer User Manual
Contents
6.10
6.11
6.12
6.13
6.9.1 Using The Keyboard To Navigate Through Menus . .
6.9.1.1 Sub-Menus . . . . . . . . . . . . . . . . . .
6.9.1.2 Numeric Parameters . . . . . . . . . . . . .
6.9.1.3 Y/N Parameters . . . . . . . . . . . . . . .
6.9.1.4 Alpha Parameters . . . . . . . . . . . . . .
6.9.1.5 String Entry Parameters . . . . . . . . . . .
6.9.2 Using The Touchscreen To Navigate Through Menus
6.9.2.1 Sub-Menus . . . . . . . . . . . . . . . . . .
6.9.2.2 Numeric Parameters . . . . . . . . . . . . .
6.9.2.3 Y/N Parameters . . . . . . . . . . . . . . .
6.9.2.4 Alpha Parameters . . . . . . . . . . . . . .
6.9.2.5 String Entry Parameters . . . . . . . . . . .
6.9.3 Saving Changes To Parameters . . . . . . . . . . . .
6.9.4 Retrieving Default Parameter Values . . . . . . . . .
Resetting The 7535 Hand-Held Computer . . . . . . . . . .
The Parameters Menu . . . . . . . . . . . . . . . . . . . . .
6.11.1 Security Settings . . . . . . . . . . . . . . . . . . . .
Display Options . . . . . . . . . . . . . . . . . . . . . . . .
More Parameters . . . . . . . . . . . . . . . . . . . . . . .
6.15 System Parameters . . . . . . . . . . . . . . . . . . . .
6.15.1 Keyboard . . . . . . . . . . . . . . . . . . . . . .
6.15.1.1 Macro Control Panel. . . . . . . . . . .
6.15.1.2 Indicators. . . . . . . . . . . . . . . . .
6.15.1.3 Softkeys . . . . . . . . . . . . . . . . .
6.15.1.4 Ctrl Panel . . . . . . . . . . . . . . . .
6.15.2 Audio . . . . . . . . . . . . . . . . . . . . . . . .
6.15.3 Power Mgmt Ctrl Panel . . . . . . . . . . . . . .
6.15.4 Security. . . . . . . . . . . . . . . . . . . . . . .
6.15.4.1 Default Mode . . . . . . . . . . . . . .
6.15.4.2 User Level Options . . . . . . . . . . .
6.15.4.3 Sup. Password . . . . . . . . . . . . . .
6.15.4.4 Allow Teklogix . . . . . . . . . . . . .
6.16 Scanner Control Panel. . . . . . . . . . . . . . . . . . .
6.17 View Manager . . . . . . . . . . . . . . . . . . . . . . .
6.17.1 Split Screen. . . . . . . . . . . . . . . . . . . . .
6.17.1.1 Splitting And Displaying Screens . . . .
6.17.1.2 Moving Between Split Screens . . . . .
6.17.1.3 Toggling Between Full & Split Screens .
170
170
170
171
171
171
173
173
174
174
174
174
175
175
175
176
176
177
177
180
181
181
182
182
182
183
184
185
185
185
186
186
187
187
188
189
190
190
Psion Teklogix 7535 Hand-Held Computer User Manual
vii
Contents
6.17.1.4 Using The Asterisk As A Wild Card . . . . . .
6.17.2 Custom Characters (Unicode™) . . . . . . . . . . . . .
6.17.2.1 Creating A Unicode™ Character. . . . . . . .
6.17.2.2 Displaying The Unicode™ Pop-up Window . .
6.18 Applications . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.18.1 ANSI Settings. . . . . . . . . . . . . . . . . . . . . . .
6.18.1.1 Host Conn . . . . . . . . . . . . . . . . . . .
6.18.1.2 Screen. . . . . . . . . . . . . . . . . . . . . .
6.18.1.3 Xmit Modes . . . . . . . . . . . . . . . . . .
6.18.1.4 Kbd Modes . . . . . . . . . . . . . . . . . . .
6.18.1.5 Edit Modes . . . . . . . . . . . . . . . . . . .
6.18.1.6 Serial . . . . . . . . . . . . . . . . . . . . . .
6.18.1.7 Host Char Set . . . . . . . . . . . . . . . . . .
6.18.1.8 Anchor View . . . . . . . . . . . . . . . . . .
6.18.2 TESS Settings. . . . . . . . . . . . . . . . . . . . . . .
6.18.2.1 Host Conn. . . . . . . . . . . . . . . . . . . .
6.18.2.2 Screen. . . . . . . . . . . . . . . . . . . . . .
6.18.2.3 Characters . . . . . . . . . . . . . . . . . . .
6.18.2.4 Tests . . . . . . . . . . . . . . . . . . . . . .
6.18.2.5 Features. . . . . . . . . . . . . . . . . . . . .
6.18.2.6 Scanner . . . . . . . . . . . . . . . . . . . . .
6.18.2.7 Fields . . . . . . . . . . . . . . . . . . . . . .
6.18.2.8 Anchor View . . . . . . . . . . . . . . . . . .
6.18.2.9 Emulation. . . . . . . . . . . . . . . . . . . .
6.19 Ports– Tether And Console. . . . . . . . . . . . . . . . . . . .
6.19.1 Tether And Console Port Peripheral Options. . . . . . .
6.19.2 Tether And Console Port Parameter Settings. . . . . . .
6.19.3 Tether And Console Port Scan-See Parameters . . . . .
6.19.3.1 Scan-See Sub-Menu – Mapping The Viewport
6.19.3.2 Scan-See Keyboard Mapping . . . . . . . . .
6.20 Network . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
6.20.1 Network Ctrl Panel Settings . . . . . . . . . . . . . . .
6.20.2 802.IQ v2 . . . . . . . . . . . . . . . . . . . . . . . . .
.190
.191
.191
.192
.194
.195
.196
.199
.202
.206
.209
.210
.210
.211
.212
.213
.214
.216
.218
.219
.223
.224
.227
.227
.235
.235
.236
.239
.239
.244
.244
.245
.245
External Bar Code Readers . . . . . . . . . . . . . . . . . . . .
7.1.1 PowerScan™ Standard, LR and XLR Bar Code Scanners .
7.1.2 Entering Data With The Bar Code Reader . . . . . . . . .
The 7535 Battery. . . . . . . . . . . . . . . . . . . . . . . . . .
.251
.251
.251
.251
Chapter 7: Peripheral Devices & Accessories
7.1
7.2
viii
Psion Teklogix 7535 Hand-Held Computer User Manual
Contents
7.3
7.4
7.5
7.6
7.7
7.8
7.9
7.2.1 Lithium-Ion Battery Safety Precautions . . . . . . . . . . .
Important Charger Safety Instructions . . . . . . . . . . . . . . .
Chargers . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
Gang Charger . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.5.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . .
7.5.2 Operator Controls . . . . . . . . . . . . . . . . . . . . . .
7.5.3 Charge Indicators. . . . . . . . . . . . . . . . . . . . . . .
7.5.4 Charging Batteries . . . . . . . . . . . . . . . . . . . . . .
7.5.5 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . .
7.5.5.1 Excessive Charge Duration . . . . . . . . . . . .
7.5.5.2 Indicator Flashing Red. . . . . . . . . . . . . . .
7.5.5.3 Power LED Does Not Light Up . . . . . . . . . .
7.5.5.4 Indicator Does Not Light When Battery Installed .
Combo Charger . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.6.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . .
7.6.2 Operator Controls . . . . . . . . . . . . . . . . . . . . . .
7.6.3 Using the Combo Charger With The 7535. . . . . . . . . .
7.6.4 Charging The Spare Battery . . . . . . . . . . . . . . . . .
7.6.5 Charge Indicators. . . . . . . . . . . . . . . . . . . . . . .
7.6.6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . .
Combo Dock . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.7.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . .
7.7.2 Using The Combo Dock . . . . . . . . . . . . . . . . . . .
7.7.3 Network Access . . . . . . . . . . . . . . . . . . . . . . .
7.7.4 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . .
Quad Dock . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
7.8.1 Installation . . . . . . . . . . . . . . . . . . . . . . . . . .
7.8.2 Indicators And Controls . . . . . . . . . . . . . . . . . . .
7.8.3 Using The Quad Dock . . . . . . . . . . . . . . . . . . . .
7.8.4 Network Access . . . . . . . . . . . . . . . . . . . . . . .
7.8.4.1 Network Addressing . . . . . . . . . . . . . . . .
7.8.5 Battery Charging . . . . . . . . . . . . . . . . . . . . . . .
7.8.6 Troubleshooting . . . . . . . . . . . . . . . . . . . . . . .
7.8.6.1 Network Link Unsuccessful . . . . . . . . . . . .
7.8.6.2 7535 LED Does Not Light When Docked. . . . .
Portable Docking Module (PDM). . . . . . . . . . . . . . . . . .
252
253
254
254
255
255
256
256
257
257
257
257
258
258
258
259
259
259
260
260
261
261
261
261
262
262
262
263
263
263
263
263
264
264
264
264
Psion Teklogix 7535 Hand-Held Computer User Manual
ix
Contents
7.11 The 7535 Picker Cradle . . . . . . . . . . . . . . . . . . . .
7.11.1 Picker Cradle Mounting Recommendations . . . . . .
7.11.1.1 Mounting Template. . . . . . . . . . . . . .
7.11.2 Wiring Guidelines . . . . . . . . . . . . . . . . . . .
7.11.3 Using The Picker Cradle . . . . . . . . . . . . . . . .
7.11.4 Maintaining The Picker Cradle . . . . . . . . . . . . .
7.11.5 Powered Cradle Installation In High Voltage Vehicles
7.11.5.1 Extreme Wet Environments . . . . . . . . .
7.11.6 Powered Cradle Installation . . . . . . . . . . . . . .
7.11.6.1 Wiring Vehicle Power To The Cradle . . . .
7.11.7 The Port Replicator . . . . . . . . . . . . . . . . . . .
.268
.269
.269
.270
.270
.270
.271
.271
.272
.273
.274
.277
.279
.279
.279
.280
.280
.281
.281
.282
.284
.284
.284
.287
.288
Chapter 8: Specifications
8.1
8.2
8.3
8.4
8.5
8.6
7535 Hand-Held Computer Specifications . . . . . . . . . .
RFID Specifications . . . . . . . . . . . . . . . . . . . . . .
Bar Code Scanning. . . . . . . . . . . . . . . . . . . . . . .
8.3.1 Internal Scanners . . . . . . . . . . . . . . . . . . . .
8.3.2 Internal Scanner Port . . . . . . . . . . . . . . . . . .
8.3.3 External Scanners . . . . . . . . . . . . . . . . . . . .
Internal Scanner Specifications . . . . . . . . . . . . . . . .
8.4.1 SE1200 High Performance & Long Range Specs . . .
8.4.2 SE1200 Advanced Long Range & SE2223 PDF Specs
8.4.3 Decode Zones . . . . . . . . . . . . . . . . . . . . . .
External Scanner Specifications . . . . . . . . . . . . . . . .
8.5.1 PowerScan™ LR and XLR Industrial Scanner Specs .
8.5.2 PowerScan™ Standard Range Scanner Specs . . . . .
Lithium-Ion Battery Pack . . . . . . . . . . . . . . . . . . .
Appendix A: Support Services And Worldwide Offices
A.1 Support Services . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A-1
A.1.1 Canada and USA: Technical Support and Repair Services . . .A-1
A.1.2 International Support. . . . . . . . . . . . . . . . . . . . . . .A-1
Appendix B: Port Pinouts
B.1 7535 Tether Port Pinout . . . . . . . . . . . . . . . . . . . . . . . . .B-1
Psion Teklogix 7535 Hand-Held Computer User Manual
Contents
B.2 Docking Station Connector . . . . . . . . . . . . . . . . . . . . . . . B-1
B.3 Battery Contacts . . . . . . . . . . . . . . . . . . . . . . . . . . . . . B-2
Appendix C: USB Setup Application
C.1 USB Setup. . . . . . . . . . . . . . . . . . . . . . . . . . . . .
C.1.1 Launching The Application . . . . . . . . . . . . . . . .
C.1.2 Pre-Installation: Updating usbstor.inf And wceusbsh.inf .
C.1.3 Installation: Installing The 7535 As a Device On Your PC
C.1.4 Post Installation . . . . . . . . . . . . . . . . . . . . . .
C-1
C-1
C-2
C-4
C-5
Psion Teklogix 7535 Hand-Held Computer User Manual
xi
APPROVALS AND SAFETY SUMMARY
Declaration Of Conformity
Product:
Application of Council
Directive(s):
Conformity Declared
to Standards:
Manufacturer:
Year of Manufacture:
Manufacturer’s Address
in the European
Community:
Type of Equipment:
Equipment Class:
7535 Hand Held Micro-computer with Portable Docking Module
R&TTE Directive:
1999/5/EEC
EMC Directive:
89/336/EEC
Low Voltage Directive: 73/23/EEC
Article 3.1a (Health): EN 60950: 2000
Article 3.1b (EMC): EN 301 489-17: v1.1.1; 09-2000
Article 3.2 (RF Spectrum): EN 300 328-2: v 1.1.1; 07 2000
EN 55022: 1998 + Am 1, Class B;
EN 61000-3-2; EN 61000-3-3
EN 55024:1998;
EN 61000-4-2; ±4kV CD; ±8kV AD
EN 61000-4-3; 3V/m, 80-1000 MHz
EN 61000-4-4; ±1kV Power lines
EN 61000-4-5; ±1kV Differential mode
EN 61000-4-6; 3VRMS, 150kHz-80MHz
EN 61000-4-11; AC Mains Ports
PSION TEKLOGIX INC.
2100 Meadowvale Boulevard
Mississauga, Ontario, Canada
L5N 7J9
2003
PSION TEKLOGIX S.A.
La Duranne; 135 Rue Rene Descartes; BP 421000
13591 Aix-En-Provence
Cedex 3; France
Information Technology Equipment
Commercial and Light Industrial
I the undersigned hereby declare that the equipment specified above conforms to
the above directives and standards.
Manufacturer:
Legal Representative
Rob Williams
Vice President of Engineering
Psion Teklogix Inc. Ontario
Domique Binckly
Vice President International Sales
Psion Teklogix S.A. France
Psion Teklogix 7535 Hand-Held Computer User Manual
xiii
Approvals And Safety Summary
FCC DECLARATION OF CONFORMITY (DoC)
Applicant’s Name & Address:
PSION TEKLOGIX
2100 Meadowvale Blvd.
Mississauga, Ontario
Canada L5N 7J9
Contact Person: Iain Roy
Telephone No.: (905) 813-9900
US Representative’s Name & Address:
1810 Airport Exchange Blvd., Suite 500
Erlanger, KY, 41018, USA
Contact Person: Joe Musgrave
Telephone No.: (859) 372-4106
Equipment Type/Environment:
Computing Devices
Trade Name / Model No.:
7535 Hand Held Micro-computer with
Portable Docking Module
Year of Manufacture:
2003
Standard(s) to which Conformity is Declared:
The 7535 Hand Held Micro-computer with Portable Docking Module, supplied by Psion
Teklogix, has been tested and found to comply with FCC PART 15, SUBPART B UNINTENTIONAL RADIATORS, CLASS B COMPUTING DEVICES FOR
HOME & OFFICE USE.
I, the undersigned, hereby declare that the equipment as tested is representative within
manufacturing tolerance to units.
xiv
Applicant
Legal Representative in U.S.
Signature
Signature
Rob Williams
Joe Musgrave
Full Name
Full Name
Vice President of Engineering
V.P. Global Solutions, Americas
Position
Position
Mississauga, Ontario, Canada
Erlanger, KY 41018, USA
Place
Place
July 4, 2003
July 4, 2003
Date
Date
Psion Teklogix 7535 Hand-Held Computer User Manual
Approvals And Safety Summary
This equipment complies with Class B Part 15 of the FCC rules.
Operation is subject to the following two conditions:
1. This device may not cause harmful interference, and
2. This device must accept any interference received, including interference that may cause undesired operation.
Changes or modifications not expressly approved by Psion Teklogix, the party
responsible for compliance, may void the user's authority to operate the equipment.
1. FCC Information to Users
For Class B Unintentional Radiators:
This equipment has been tested and found to comply with the limits for a Class B
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to
provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and can radiate radio frequency energy
and, if not installed and used in accordance with the instruction manual, may
cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment
does cause harmful interference to radio or television reception, which can be
determined by turning the equipment off and on, the user is encouraged to try to
correct the interference by one of more of the following measures:
•
Reorient or relocate the receiving antenna
•
Increase the separation between the equipment and receiver
•
Connect the equipment into an outlet on a circuit different from that to
which the receiver is connected.
•
Consult the dealer or an experienced radio/TV technician for help.
2. Warning to Users
Warning:
Changes or modifications not expressly approved by Psion
Teklogix Inc. could void the user's authority to operate the
equipment.
Psion Teklogix 7535 Hand-Held Computer User Manual
xv
Approvals And Safety Summary
LASER WARNINGS
For your own safety, it is critical that you comply with the following warnings:
CAUTION
Do not look into the laser beam or point the beam at people or animals.
CAUTION
Using controls or adjustments, or performing procedures other than those
specified herein may result in hazardous radiation exposure.
CAUTION
The use of optical instruments with this product will increase eye hazard.
This product contains a laser scanner that emits less than 1.2 mW maximum radiant
power at a wavelength of 650nm or 680nm. This product complies with 21 CFR
1040.10, 1040.11 and DIN EN 60825-1: 2001, and is classified as a Class 2 laser
product.
The SE1200 ALR has an maximum radiated power less than 1.4 mW; according to
EN 60825-1: 2001 it is classified as a Class 3B laser product.
DO NOT OPERATE IN AN EXPLOSIVE ATMOSPHERE
Operating Psion Teklogix equipment where explosive gas is present may
result in an explosion.
DO NOT REMOVE COVERS OR OPEN ENCLOSURES
To avoid injury, the equipment covers and enclosures should only be
removed by qualified service personnel. Do not operate the equipment
without the covers and enclosures properly installed.
xvi
Psion Teklogix 7535 Hand-Held Computer User Manual
Approvals And Safety Summary
CAUTION!
Danger of explosion if a 7535 battery is incorrectly handled, charged,
disposed of or replaced. Replace only with the same or equivalent type
recommended by the manufacturer. Dispose of used batteries according to
the instructions described in “Lithium-Ion Battery Safety Precautions” on
page 252. Carefully review all battery safety issues.
VORSICHT!
Explosiongefahr bei unsachgemäßem Austausch der Batterie Ersatz nur
durch denselben oder einen vom Hersteller empfohlenen gleichwertigen
Typ. Entsorgung gebrauchter Batterien nach Angaben des Herstellers.
Psion Teklogix 7535 Hand-Held Computer User Manual
xvii
1
INTRODUCTION
1.1 About This Manual . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 3
1.2 Text Conventions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4
1.3 About The 7535 Hand-Held Computer
1.3.1 Features . . . . . . . . . . . . .
1.3.2 The 7535 Hand-Held Computer .
1.3.3 Regulatory Labels . . . . . . . .
. . . . . . .5
. . . . . . . 5
. . . . . . . 7
. . . . . . . 9
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 1: Introduction
About This Manual
1.1 About This Manual
This manual describes how to configure, operate and maintain the Psion Teklogix
7535 hand-held computer.
Chapter 1: Introduction
provides a basic overview of the 7535 hand-held.
Chapter 2: Basic Checkout
describes the steps required to get the 7535 ready for operation.
Chapter 3: Getting To Know Your 7535
describes the 7535 features and outlines how to charge and maintain the battery.
This chapter also provides a description of the keyboard, how to navigate in
Microsoft® Windows® CE, how to use the internal scanner, and so on.
Chapter 4: Working With Windows CE
describes the Microsoft® Windows® CE desktop and how to use it. This
chapter also outlines the basics of moving around a Windows CE window,
selecting and opening icons, files, folders and working with a Windows
dialogue box.
Chapter 5: Configuration
provides a description of the Windows CE Control Panel and how to use it
to configure the 7535, along with the scanners attached to the hand-held,
and so on.
Chapter 6: Tekterm Application
describes TESS and ANSI operations. This chapter also provides descriptions of
the Tekterm parameters.
Chapter 7: Peripheral Devices & Accessories
describes the peripherals and accessories available for your 7535 hand-held.
Chapter 8: Specifications
details radio, hand-held computer and battery specifications.
Appendix A: Support Services And Worldwide Offices
provides the helpdesk phone number at the Mississauga, Ontario, Canada office
and details the support services available. This appendix also lists the worldwide office addresses and phone numbers.
Appendix B: Port Pinouts
includes 7535 pinouts.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 1: Introduction
Text Conventions
1.2 Text Conventions
Note: Notes highlight additional helpful information.
Important:
These statements provide particularly important instructions
or additional information that is critical to the operation of
the equipment.
Warning:
These statements provide critical information that may prevent
physical injury, equipment damage or data loss.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 1: Introduction
About The 7535 Hand-Held Computer
1.3 About The 7535 Hand-Held Computer
The 7535 is a ruggedized hand-held personal computer, running the Microsoft®
Windows® CE.net operating system. It is intended for use in commercial and light
industrial applications with a focus on real time wireless data transactions. All
possible bar code input methodologies are supported by one of the variety of
scanners available. Optimization for specific operational environments is supported
with a wide range of peripheral options and carrying accessories.
1.3.1 Features
•
Rugged design:
- sealed from water and dust to IP54 (light rain) rating.
- withstands multiple drops of up to 6.5 feet onto concrete.
•
Large 240 x 320 portrait mode display that is available in colour or black
and white with or without a touchscreen
•
Automatic backlighting for both the display and the keypad.
- automatic backlight and contrast control.
- daylight readable screen.
•
Processor and memory:
- Intel PXA255 400Mhz CPU with 32 MB FLASH and 64 MB RAM
standard.
•
Microsoft® Windows® CE.net operating system
•
Application software:
- Internet Explorer for CE.
- Tekterm terminal emulation.
•
Ergonomic keyboard designed to accommodate left- and right-handed use.
•
Two keyboard formats available:
- 58-key with 6 function keys (standard).
- 36-key large button with 10 function keys.
- keypads feature EL backlight for visibility in low-light conditions.
•
Wireless communication:
- Compact FLASH slot normally equipped with an IEEE 802.11b
11 Mbps 2.4GHz Wi-Fi radio.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 1: Introduction
Features
standard antenna integrated onto radio card.
optional high performance internal antenna available.
Bluetooth SD I/O radio.
•
Expansion slot:
- SD I/O slot that supports extra FLASH memory (up to 512 MB)
•
Programming environment:
- HTML
- .net Compact framework
- Java, Visual C++
•
Bar code applications:
- internal 1D and 2D scan engines.
- internal CMOS image capture scan engine.
- supports decoded and undecoded tethered scanners.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 1: Introduction
The 7535 Hand-Held Computer
1.3.2 The 7535 Hand-Held Computer
Figure 1.1 7535 With 58-Key Keyboard
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 1: Introduction
The 7535 Hand-Held Computer
Figure 1.2 7535 Docking Port
Figure 1.3 Tether Port
Figure 1.4 Scanner Window
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 1: Introduction
Regulatory Labels
1.3.3 Regulatory Labels
Figure 1.5 Laser Warning Labels
Figure 1.6 Radio Labels
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 1: Introduction
Regulatory Labels
Figure 1.7 Manufacturer’s Label
Warning:
10
Using controls or adjustments or performing procedures other than
those specified herein may result in hazardous radiation exposure.
Psion Teklogix 7535 Hand-Held Computer User Manual
2
BASIC CHECKOUT
2.1 Preparing The 7535 For Operation . . . . . . . . . . . .
2.1.1 Equipment You Need To Get Started . . . . . . . .
2.1.2 Charging The Battery . . . . . . . . . . . . . . . .
2.1.3 Attaching Carrying Accessories . . . . . . . . . .
2.1.3.1 Attaching The Hand Strap . . . . . . . . .
2.1.3.2 Attaching The Pistol Grip . . . . . . . . .
2.2 Powering Up The 7535 And Configuring The Radio . . .
2.2.1 Installing The Battery And Switching The 7535 On
13
13
13
13
14
15
16
17
2.2.3 Assigning An IP Address . . . . . . . . . . . .
2.2.4 Name Servers Tab. . . . . . . . . . . . . . . .
2.2.5 Advanced Features . . . . . . . . . . . . . . .
2.2.5.1 Rearranging Preferred Networks . . .
2.2.5.2 Deleting A Preferred Network . . . . .
2.2.5.3 Changing Network Properties . . . . .
Checking The Scanner . . . . . . . . . . . . . . . .
Using Microsoft® ActiveSync® To Work With Files.
Calibrating The Touchscreen . . . . . . . . . . . . .
Resetting The 7535 Hand-Held . . . . . . . . . . . .
24
25
26
26
27
27
27
27
28
28
2.3
2.4
2.5
2.6
Psion Teklogix 7535 Hand-Held Computer User Manual
11
Chapter 2: Basic Checkout
Preparing The 7535 For Operation
2.1 Preparing The 7535 For Operation
Typically, 7535 hand-helds are configured at the factory and arrive ready for use.
Although the 7535 is equipped with an internal Compact Flash and SD I/O slot,
these slots are not intended for user modification. If a device needs to be changed or
added in these slots, contact qualified Psion Teklogix personnel. Refer to
Appendix A: Support Services And Worldwide Offices for the service number
closest to you.
2.1.1 Equipment You Need To Get Started
You’ll need:
•
•
•
A 7535 compatible battery charger, docking station or portable docking
module (PDM) with power supply.
An operating wireless network (if you are not operating the equipment in
batch mode).
A medium Phillips head screwdriver.
2.1.2 Charging The Battery
Important:
The 7535 uses a high capacity Lithium-Ion battery. It is critical
that you review the battery safety guidelines in “Lithium-Ion
Battery Safety Precautions” on page 252 before charging the
battery.
Batteries shipped from the factory are not charged. They must be fully charged prior
to use. Full capacity may not be reached until at least 5 full charge/discharge cycles
have been performed.
7535 batteries can be charged using a gang charger or the 7535 internal charger.
When using the internal charger, a suitable power source is required. All chargers
and docking stations are described in Chapter 7: Peripheral Devices & Accessories
beginning on page 254.
2.1.3 Attaching Carrying Accessories
Psion Teklogix recommends that a carrying accessory – a hand strap, pistol grip or
shoulder strap – be installed on the 7535 before use.
If your hand-held is not fitted with a hand strap or pistol grip, you can install either
using the carrying accessory kit supplied. You’ll need:
•
A Phillips head screwdriver.
Psion Teklogix 7535 Hand-Held Computer User Manual
13
Chapter 2: Basic Checkout
Attaching The Hand Strap
Important:
2.1.3.1
Do not use adhesives such as Loctite to secure the screws on the
carrying accessories. These chemicals may damage the plastic
casing.
Attaching The Hand Strap
Note: A Phillips head screwdriver is required.
Two Phillips head screws are provided with the hand strap.
•
Attach the strap to the two threaded inserts located at the back of the 7535
near the top of the unit.
Figure 2.1 Attaching The Hand Strap
14
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 2: Basic Checkout
Attaching The Pistol Grip
•
Stretch the handstrap toward the base of the 7535, and hook the bottom of
the handstrap into the slot near the base of the battery pack.
Figure 2.2 Hooking The Hand Strap To The 7535
2.1.3.2
Attaching The Pistol Grip
Note: A Phillips head screwdriver is required.
The pistol grip is attached to the back of the 7535 using the four threaded inserts in
the upper part of the 7535 casing. Four black #4-40 Phillips head screws are
provided with this accessory.
Note: Prior to installation, make sure the trigger mechanism is securely
snapped into the pistol grip body and that the trigger operates properly.
Psion Teklogix 7535 Hand-Held Computer User Manual
15
Chapter 2: Basic Checkout
Powering Up The 7535 And Configuring The Radio
•
Position the pistol grip so that it fits snugly over the back of the unit and
the inserts on the back of the 7535 align with the holes in the pistol grip.
Figure 2.3 Attaching The Pistol Grip
•
Using a Phillips screwdriver, securely fasten the pistol grip to the back of
the 7535.
2.2 Powering Up The 7535 And Configuring The Radio
Note: Psion Teklogix offers a Portable Docking Module (PDM) along with its
power supply to help speed the checkout and confirmation process for
your 7535. The PDM can power your hand-held with or without a battery
installed in the 7535. Refer to Chapter 7: Peripheral Devices & Accessories beginning on page 249 for more information about this accessory.
16
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 2: Basic Checkout
Installing The Battery And Switching The 7535 On
2.2.1 Installing The Battery And Switching The 7535 On
If you are not using a docking station or PDM:
•
Slide the charged battery with the contoured plastic facing you into the
7535. Click the battery into place.
Figure 2.4 Installing The Battery
Note: If you are using a docking station, you can insert an uncharged battery,
dock the unit and switch it on.
If you are using a PDM, you can configure your unit without a battery, with
a charged battery or with an uncharged battery.
If you are using a hand strap:
•
Hook the bottom of the hand strap into the slot at the base of the battery.
To switch the 7535 on:
•
•
Press and hold down the  key for at least one second.
When all four LEDs flash orange, release the  button.
A splash screen displaying the Psion Teklogix logo and the Microsoft®
Windows® CE. net logo appears. When Windows® CE has successfully loaded, the
startup desktop is displayed.
Note: The screen may go blank for a few seconds after the splash screen loading
bar reaches the end. This is part of the normal Windows CE cold boot
process. The desktop is displayed after a few moments.
Psion Teklogix 7535 Hand-Held Computer User Manual
17
Chapter 2: Basic Checkout
Name Servers Tab
•
•
Press the  arrow key to highlight Specify an IP address.
Press the  key to move from field to field, and type an IP, Subnet Mask
and Default Gateway address. Press  to save your information.
2.2.4 Name Servers Tab
Note: If DHCP is enabled, name server addresses are assigned automatically.
•
•
•
In the $NETWLAN1 Settings window, press the  key followed by the
 arrow key to display the IP Information tab.
In the IP Information tab, highlight the Configure... button, and press
.
Press the  key followed by the  arrow key to display the
Name Servers tab.
Figure 2.13 Name Servers Tab
The DNS and WINS fields in the Name Servers tab allow you to specify additional
WINS and DNS resolvers. The format for these fields is ###.###.###.###.
Psion Teklogix 7535 Hand-Held Computer User Manual
25
Chapter 2: Basic Checkout
Advanced Features
2.2.5 Advanced Features
To display the Advanced Wireless Settings dialogue box:
•
Highlight the Advanced... button in the Wireless Information tab and press
.
This window lists the available preferred networks.
Figure 2.14 Advanced Settings
2.2.5.1
Rearranging Preferred Networks
The 7535 attempts to connect with the networks listed in this dialogue box in
sequence, beginning at the top of the list. If you need to rearrange this list of
networks – move networks up and down in the list:
•
•
•
26
Press the  key to move the cursor into the networks list.
Use the  or  arrow keys to highlight the network that you
want to move up or down in the list.
To move the highlighted item in the list upward or downward, press 
to highlight the Up or Down button, and press .
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 2: Basic Checkout
Deleting A Preferred Network
2.2.5.2
Deleting A Preferred Network
To delete a network from this list:
• Press the  key to highlight the networks list.
• Use the  or  arrow keys to highlight the network that you
want to remove.
• Highlight the Delete button, and press .
2.2.5.3
Changing Network Properties
To change the properties of an existing preferred network:
• Highlight the network that you want to modify.
• Press  to highlight the Properties button, and press .
• Make any necessary changes in the Wireless Properties dialogue box, and press
 to save the changes.
2.3 Checking The Scanner
If your 7535 is equipped with an internal scanner, it will successfully decode most
1D bar codes as delivered. Press the SCAN button and check for a valid decode on
any UPC bar code. If desired, set the “Dot Time” parameter to zero in the ‘Teklogix
Scanners’ applet in the Control Panel to turn off the default aiming dot.
Performance is improved if you disable all unneeded bar codes under the ‘Bar
Codes’ dialogue screen. Review “Scanner Properties Setup” on page 118 for details
about bar codes.
2.4 Using Microsoft® ActiveSync® To Work With Files
ActiveSync® – Microsoft PC connectivity software – can be used to connect the
7535 to PCs running this software. By connecting the 7535 to a PC with a cable and
running ActiveSync on the PC, you can:
• View 7535 files from Windows Explorer.
• Drag and drop files between the 7535 and the PC in the same way that you
would between PC drives.
• Back up 7535 files to the PC, then restore them from the PC to the
hand-held again, if needed, and so on.
Note: You’ll need the USB setup utility to configure the .ini file. For information
about this USB application, refer to Appendix C: USB Setup Application.
Psion Teklogix 7535 Hand-Held Computer User Manual
27
Chapter 2: Basic Checkout
Calibrating The Touchscreen
To install ActiveSync, follow the step-by-step instructions provided with the
program’s setup wizard. Refer to the following website for details:
http://www.microsoft.com/windowsmobile/resources/downloads/pocketpc/activesync35.mspx
2.5 Calibrating The Touchscreen
If your 7535 is equipped with a touchscreen, it will need to be calibrated. Refer to
“Calibrating The Touchscreen” on page 41 for details.
2.6 Resetting The 7535 Hand-Held
Important:
Because Psion Teklogix cannot guarantee what has been saved
(registry) after a reset, this should be considered as a last resort.
To reset the 7535:
•
Press and hold down the  key and the  key simultaneously for a minimum of six seconds.
A reset results in a complete reboot of the unit. All RAM memory contents are lost.
The contents of the flash memory and memory card may be preserved, but Psion
Teklogix cannot guarantee. However, you should keep in mind that When the 7535
is reset, the screen displays the Psion Teklogix and Microsoft® Windows® CE.net
splash screen before displaying the startup desktop.
Note: You do not need to reset your 7535 after configuring the radio.
28
Psion Teklogix 7535 Hand-Held Computer User Manual
3
GETTING TO KNOW YOUR 7535
3.1 Features Of The 7535 . . . . . . . . . . . . . . . . . . . . . . . .
3.2 The Battery . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.1 Battery Safety . . . . . . . . . . . . . . . . . . . . . . . . .
3.2.2 Removing And Installing The Battery Pack . . . . . . . . .
3.2.3 Charging The Battery . . . . . . . . . . . . . . . . . . . . .
3.3 Switching The 7535 Hand-Held On And Off . . . . . . . . . . . .
3.4 The Keyboard . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.1 Modifier Keys. . . . . . . . . . . . . . . . . . . . . . . . .
3.4.1.1 Activating Modifier Keys . . . . . . . . . . . . . .
3.4.1.2 Locking Modifier Keys . . . . . . . . . . . . . . .
3.4.2 The Keys . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.4.3 The 58-Key Keyboard . . . . . . . . . . . . . . . . . . . .
3.4.4 The 36-Key Keyboard . . . . . . . . . . . . . . . . . . . .
3.4.5 The Keypad Backlight . . . . . . . . . . . . . . . . . . . .
3.5 The Display . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.5.1 Adjusting The Display Backlight . . . . . . . . . . . . . . .
3.5.2 Adjusting The Contrast . . . . . . . . . . . . . . . . . . . .
3.5.3 Calibrating The Touchscreen . . . . . . . . . . . . . . . . .
3.6 7535 Indicators . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.1 LEDs . . . . . . . . . . . . . . . . . . . . . . . . . . . . .
3.6.1.1 Charge LED . . . . . . . . . . . . . . . . . . . . .
3.6.1.2 Radio Traffic LED . . . . . . . . . . . . . . . . . .
3.6.1.3 Scan LED . . . . . . . . . . . . . . . . . . . . . .
3.6.1.4 User Application LED . . . . . . . . . . . . . . . .
3.6.2 Onscreen Indicators. . . . . . . . . . . . . . . . . . . . . .
3.6.3 Audio Indicators . . . . . . . . . . . . . . . . . . . . . . .
3.6.3.1 Adjusting The Beeper Volume . . . . . . . . . . . .
3.7 Internal Scanners . . . . . . . . . . . . . . . . . . . . . . . . . .
3.7.1 Scanning Techniques . . . . . . . . . . . . . . . . . . . . .
3.7.2 Scan LED Indicators . . . . . . . . . . . . . . . . . . . . .
3.7.3 Troubleshooting. . . . . . . . . . . . . . . . . . . . . . . .
3.7.4 Operating One Dimensional (1D) Internal Laser Scanners. .
3.7.5 Operating Internal PDF Laser Scanners . . . . . . . . . . .
3.7.6 Operating Internal Two Dimensional (2D) Imager Scanners.
31
32
32
32
33
34
35
35
36
36
36
37
38
40
40
40
41
41
42
42
43
44
44
44
45
47
48
48
49
49
50
50
51
51
Psion Teklogix 7535 Hand-Held Computer User Manual
29
Chapter 3: Getting To Know Your 7535
3.8 Connecting & Disconnecting Tethered Peripherals .
3.9 Monitoring The Battery And Maximizing Run Time
3.9.1 Storing Batteries. . . . . . . . . . . . . . . .
3.10 Monitoring The Network Connection . . . . . . .
3.11 Uploading Data In A Docking Station . . . . . . .
3.12 General Maintenance. . . . . . . . . . . . . . . .
3.12.1 Caring For The Touchscreen . . . . . . . . .
3.12.2 Cleaning The 7535 . . . . . . . . . . . . . .
30
Psion Teklogix 7535 Hand-Held Computer User Manual
52
53
55
55
56
56
56
57
Chapter 3: Getting To Know Your 7535
Features Of The 7535
3.1 Features Of The 7535
7535 Screen
Sound Port
Ambient Light Sensor
Tether Port
Docking Port
Figure 3.1 Front Of 7535
Stylus
(Pointing Tool)
Scanner Window
Battery Pack
Tether Port
Figure 3.2 Back Of 7535
Psion Teklogix 7535 Hand-Held Computer User Manual
31
Chapter 3: Getting To Know Your 7535
The Battery
3.2 The Battery
The 7535 hand-held operates with a Lithium-Ion battery pack. Preparing the
hand-held unit for operation requires that a battery pack be charged and installed in
the unit.
3.2.1 Battery Safety
Important:
Before attempting to install, use or charge the battery pack, it is
critical that you review and follow the important safety guidelines
in the section entitled “Lithium-Ion Battery Safety Precautions”
beginning on page 252.
3.2.2 Removing And Installing The Battery Pack
Note: TURN OFF THE 7535 HAND-HELD BEFORE REMOVING THE
BATTERY PACK. If you do not turn the hand-held off before removing
the battery, it may be necessary to reboot the unit. Any active sessions
will be lost.
Removing The Battery Pack
•
•
32
If your 7535 is equipped with a hand strap, unhook it from the base of the
battery.
Press down the release tab at the top of the battery, and slide the battery out.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
Charging The Battery
Installing The Battery Pack
To install the battery pack:
•
Slide the battery pack with the contoured plastic facing you into the 7535.
Click the battery into place.
Figure 3.3 Installing The Battery Pack
•
If your computer is equipped with a hand strap, insert the hook at the end of
the hand strap into the slot at the base of the battery.
3.2.3 Charging The Battery
Important:
FOR DETAILED INFORMATION about 7535 chargers and
docking stations, refer to Chapter 7: Peripheral Devices & Accessories beginning on page 249. For battery safety, refer to “Lithium-Ion Battery Safety Precautions” beginning on page 252.
All batteries must be charged before use. The 7535 battery can be charged with a
variety of chargers. These include:
•
•
•
6-Gang Charger (Model #HU3006) – charges up to six Lithium-Ion batteries at one time.
Portable Docking Module (Model #HU4001 or HU1005 and HU3220 or
HU3220) – charges the 7535 battery (with the battery installed in the unit).
Combo Charger (Model #HU3002) – a desktop charger that charges the
7535 internal battery along with a spare battery pack.
Psion Teklogix 7535 Hand-Held Computer User Manual
33
Chapter 3: Getting To Know Your 7535
Switching The 7535 Hand-Held On And Off
•
•
•
Combo Docking Station (Model #HU4002) – operates as both a charger
and a docking station. Operating as a charger, both the battery installed in
the computer and a spare battery can be charged simultaneously.
Quad Docking Station (Model #HU4004) – can charge the battery of up to
four 7535s inserted in the docking station while transferring data through an
Ethernet connection.
Powered Cradle (Model #HU1000, HU1010) – can charge the 7535 with
the battery installed in the hand-held.
It can take from 1.5 to 4 hours to charge a battery. The 7535’s intelligent charging
system protects the battery from over-charging by terminating the charge process
when the battery is at maximum capacity.
Note: Refer to “Monitoring The Battery And Maximizing Run Time” on page 53
for additional information about the 7535 battery.
Important:
To avoid damaging the battery, chargers will not begin the charge
process until the battery temperature is between 0˚C (32˚F) and
39˚C (102˚F). If the battery is too hot or cold, the battery status
LED flashes yellow and the charge is suspended. Refer to
Table 3.1, “Charge LEDs” on page 43 for details.
3.3 Switching The 7535 Hand-Held On And Off
Switching On The 7535
•
•
Press and hold down the  key for at least one second.
When all four LEDs flash orange, release the  button.
A splash screen displaying the Psion Teklogix logo and the Microsoft®
Windows® CE. net logo appears followed by the startup desktop.
Note: If the 7535 is in suspend state, pressing  key ‘wakes’ the
unit from this state. The screen in which you were working before the
computer entered suspend state is displayed.
34
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
The Keyboard
Switching Off The 7535
Important:
Keep in mind that turning off the 7535 does not result in a
complete reboot; rather, the unit enters a power-saving,
“suspend” state. When the 7535 is turned on from suspend state,
operation resumes within a few seconds.
To switch off the 7535:
•
Press the  key, and then press the  key.
Important:
If the word ‘BLUE’ is displayed in uppercase in the taskbar area
at the bottom of the screen, this key is locked “on” – the 7535 will
not switch off. Press the  key again to unlock it; then
press   to switch the 7535 off.
If, however, you’ve disabled the “Blue Key” in the ‘One Shot’ dialogue box (see “Keyboard One Shot Modes” on page 94), the 7535
can be turned off even when the  key is locked ‘on’.
3.4 The Keyboard
The 7535 offers two types of keyboard layouts – a 58-key keyboard and a 36-key,
large button keyboard. Most of the keys on these keyboards operate much like a
desktop computer. Where a key or key function is not consistent with the PC
keyboard, the differences are noted.
The  and  modifier keys provide access to additional keys and
system functions. These functions are colour coded in orange and blue print above
the keyboard keys.
3.4.1 Modifier Keys
The , , ,  and  keys are modifier
keys. Pressing a modifier key changes the function of the next key pressed. For
example, on a 58-key keyboard, a square bracket is printed in orange print above the
<4> key. Pressing the  key followed by the <4> key displays a square
bracket rather than the number 4.
Psion Teklogix 7535 Hand-Held Computer User Manual
35
Chapter 3: Getting To Know Your 7535
Activating Modifier Keys
The ,  and  keys operate much like a desktop keyboard
except that they are not chorded (two keys held down simultaneously). The modifier
key must be pressed first followed by the key whose function you want modified.
3.4.1.1
Activating Modifier Keys
When a modifier key is pressed once, it is displayed in lowercase letters in the
taskbar at the bottom of the 7535 screen. For example, if the  key is
pressed, ctrl key is displayed at the bottom of the unit screen. Once the next key is
pressed, the modifier key becomes inactive and disappears from the taskbar.
3.4.1.2
Locking Modifier Keys
When a modifier key is pressed twice, it is ‘locked’ on. A ‘locked’ modifier key is
displayed in uppercase letters in the taskbar. For example, pressing the  key
twice locks it on – it is displayed as BLUE KEY in the taskbar at the bottom of the
computer screen.
The locked modifier key will remain active until it is pressed a third time to unlock
or turn it off. Once a modifier key is unlocked (pressed a third time), the uppercase
representation at the bottom of the screen is no longer displayed.
Note: The locking function of the  and  keys can be disabled so that pressing either of these keys once will lock the keys ‘on’.
If you disable the ‘One Shot’ function of either of these keys, pressing the
 and/or  key once will lock the key ‘on’. Pressing
the same key a second time will unlock or turn it ‘off’. Refer to “Keyboard
One Shot Modes” on page 94 for details.
3.4.2 The Keys
The  Key
The  key is used to display uppercase alpha characters and provide access
to the symbols above the numeric keys.
The Arrow Keys
The Arrow keys move the cursor around the screen in the direction of the arrow –
up, down, left and right. The cursor is the flashing box or underline character that
indicates where the next character you type will appear.
36
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
The 58-Key Keyboard
The  Key
The  key (sometimes referred to as destructive backspace) moves the
cursor one character to the left, erasing the incorrectly entered key stroke.
The  key ( ) erases the character at the cursor position.
The  And  Key
The  and  keys modify the function of the next key pressed and are
application dependent.
The  Key
Typically, the  key moves the cursor to the next field to the right or
downward.
The  Key
Generally, this key is used as a keyboard shortcut to close the current menu,
dialogue box or activity and return to the previous one.
The  Key
Pressing this key inserts a blank space between characters. In a Windows dialogue
box, pressing the  key enables (√) or disables a checkbox.
The  Key
Pressing the  key – the yellow key with the star-burst scan symbol on it –
activates the scanner beam while pressed. For units that do not have internal
scanners, this key is inoperable.
3.4.3 The 58-Key Keyboard
In addition to alphanumeric keys that are directly accessible on the keyboard (no key
combination is required) and the keys described in this chapter, the 58-key keyboard
also provides function keys and macro keys.
Function keys  through  can be used with the CE operating system or
another application. The additional function keys –  through  along
with the macros are not used as part of the Windows CE operating system.
All function keys and macro keys can be custom defined for each application. The
Tekterm application utilizes these keys. Refer to “Additional Keyboard Functions”
on page 147 for details about Tekterm keys.
Psion Teklogix 7535 Hand-Held Computer User Manual
37
Chapter 3: Getting To Know Your 7535
The 36-Key Keyboard
3.4.4 The 36-Key Keyboard
On 36-key 7535s, all alpha characters are printed on the unit plastic in orange
typeface above the numeric keys. To access an alpha character, you must first press
the  key and then press the numeric key above which the alpha
character you want to type is printed.
Because the alpha keys on a 36-key keyboard are laid out much like the letters on a
telephone – generally in groups of three letters per numeric key – you need to take a
few extra steps to access the alphabetic characters. The examples in this section help
illustrate how to access alpha characters.
Choosing A Single Alpha Character
Note: Keep in mind that the following examples assume that ‘One Shot’ is
enabled for the  key. Refer to “Keyboard One Shot Modes”
on page 94 for details.
The examples below illustrate how to access A, B and C, all of which are printed in
orange characters above the numeric key, <2>.
To choose the letter ‘a’:
• Press the  key, and press the numeric key <2>.
To choose the letter ‘b’:
• Press the  key twice to lock it ‘on’, and press <2> twice.
• Press the  key again to unlock or turn it off.
To choose the letter ‘c’:
• Press the  key twice to lock it ‘on’.
• Press <2> three times, and then
• Press the  key again to unlock or turn it off.
Creating Uppercase Letters
To display a capital letter:
• Press the  key and then the  key before typing the
alpha character.
38
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
The 36-Key Keyboard
Choosing More Than One Alpha Character From The Same Key
If you need to choose more than one alpha character from a single key, you’ll need
to press the ‘Accept’ key between alpha selections. The ‘Accept’ key is presented as
an arrow ⇒ symbol above the ‘0’ (zero) key. Pressing this key signals the 7535 to
display the alpha character you’ve chosen and await the next selection from the
same key.
For example, suppose you want to type the letters ‘a’, ‘b’ and ‘c’. These letters are
all accessible from the numeric key, <2>.
To type the letter ‘a’:
• Press the  key twice to lock it ‘on’, and then press the numeric
key, <2>.
• Press the ‘Accept’ key < ⇒> to indicate that the letter ‘a’ should be
accepted and that another letter from the same key will be chosen.
To type the letter ‘b’:
• Press the <2> key twice.
• Press < ⇒> to accept the letter ‘b’.
To type the letter ‘c’:
• Press the <2> key three times.
When you have completed your alpha selections from this key, you can do one of the
following:
• If you want to choose additional alpha characters from another key(s),
leave the  key ‘on’, and press the next numeric key that
supports the alpha character you require.
• If you do not want to choose any additional alpha characters, press
 again to unlock or turn ‘off’ the key and end alpha selection.
Choosing Multiple Alpha Characters From A Range Of Keys
If you plan on choosing alpha characters from a number of different keys, you are
not required to press the ‘Accept’ < ⇒> key after each alpha selection. The < ⇒>
key is only required when you are choosing more than one alpha character from the
same key – e.g., ‘a’, ‘b’ and ‘c’ from the <2> key.
Psion Teklogix 7535 Hand-Held Computer User Manual
39
Chapter 3: Getting To Know Your 7535
The Keypad Backlight
Suppose you want to type the letters ‘a’, ‘d’ and ‘g’. These alpha characters are
accessed from the numeric keys <2>, <3> and <4>.
•
•
•
With the  key locked ‘on’ (press twice), press <2> to type the
letter ‘a’.
Press <3> to type ‘d’, and press <4> to type the letter ‘g’.
To end alpha selection, press the  key a third time to unlock it.
3.4.5 The Keypad Backlight
The intensity of the keypad backlight and the conditions under which this backlight
is activated can be configured using the Keyboard icon in the Windows CE Control Panel.
The behaviour of the keypad backlight is tailored in the Keyboard Properties dialogue box.
Refer to “Keyboard Backlight” on page 93 for details about this option.
Note: Keep in mind that this option may be restricted to supervisory use only.
3.5 The Display
7535s are equipped with display backlighting to improve character visibility in low
light conditions. The backlight switches on when a key is pressed and the ambient
light is below the set threshold. A light sensor on the front of the hand-held
determines the ambient light level. On some displays, the contrast can also be
adjusted to further improve character visibility.
3.5.1 Adjusting The Display Backlight
The behaviour of the display backlight – the ambient light threshold below which
the backlight will become active and the intensity of the backlight – can be specified
in the Display Properties dialogue box in the Windows CE Control Panel.
Note: Refer to “Display Backlight” on page 89 for details about the Display
Properties dialogue box.
40
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
Adjusting The Contrast
3.5.2 Adjusting The Contrast
Note: In addition to the manual adjustments described in this section, the display contrast can also be adjusted using the Windows CE Control Panel.
Refer to “Display Contrast” on page 88 for details about this dialogue
box.
The display contrast can be adjusted from the unit keyboard using the  key
and function keys  and . Pressing 
darkens the display, and
pressing 
lightens the display. Keep in mind that adjusting the contrast on
a colour display is much less pronounced than on a monochrome display.
To adjust the display contrast:
• Press the  key twice to lock it on, and then press 
. to
darken the display or 
. to lighten the display.
• Once you’ve successfully adjusted the display contrast, remember to press
the  key again to turn it ‘off’.
3.5.3 Calibrating The Touchscreen
If your 7535 touchscreen has never been calibrated or if you find that the stylus
pointer is not accurate when you tap on an item, use the Stylus Properties dialogue box in
the Windows CE Control Panel to recalibrate the screen.
•
In the Control Panel, choose the Stylus icon to display the Stylus Properties window.
Figure 3.4 Stylus Icon
Psion Teklogix 7535 Hand-Held Computer User Manual
41
Chapter 3: Getting To Know Your 7535
7535 Indicators
•
Select the Calibration tab, and then choose the ‘Recalibrate’ button.
Figure 3.5 Calibration Screen
•
Follow the directions on the calibration screen to calibrate the screen.
3.6 7535 Indicators
7535s use LEDs (Light Emitting Diode), onscreen messages and audio tones as
indicators.
3.6.1 LEDs
The 7535 is equipped with four tri-coloured LEDs. This section outlines what these
LEDs indicate.
Important:
42
If an LED is illuminated in red, the operator should be cautious
as this generally indicates an abnormal operating condition or
active laser emission.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
Charge LED
User
Application
LED
Radio Traffic
LED
Scanner
LED
Charge
LED
Figure 3.6 Keyboard LEDs
3.6.1.1
Charge LED
The lower-right LED is reserved for internal charger/power status. This indicator is
active even when the 7535 is inserted in a docking station (and in suspend mode) so
that the charge status of the battery can be detected easily.
Function
Charge LED Behaviour
External power not available.
Fully charged to within 95% of charge
capacity.
Quick charge successfully completed to
within 75% of charge capacity.
Charge in progress.
Cell temperature out of range for charge.
Unable to charge battery.
Charge circuit failure.*
LED off.
LED displays solid green colour.
LED flashes slow green.
LED displays solid yellow colour.
LED flashes yellow.
LED displays solid red colour.
LED flashes fast red.*
*If the charge fails, refer to the charger troubleshooting sections in Chapter 7: Peripheral Devices &
Accessories beginning on page 254 for helpful details.
Table 3.1 Charge LEDs
Psion Teklogix 7535 Hand-Held Computer User Manual
43
Chapter 3: Getting To Know Your 7535
Radio Traffic LED
3.6.1.2
Radio Traffic LED
The upper-left LED on your 7535 flashes either orange or green to indicate when the
radio transmits and receives data.
Note: Keep in mind that while the standard 802.11b radio supports the transmit/receive LED, not all radios support this function.
Function
Radio Traffic LED Behaviour
Radio Transmit
Radio Receive
LED flashes orange.
LED flashes green.
Table 3.2 Transmit and Receive LEDs
3.6.1.3
Scan LED
Successful scans are indicated in two ways – with a scan LED and with an
audio tone.
Function
Scan in progress
Successful scan
Unsuccessful scan
Scan LED Behaviour
LED displays solid red during scan.
LED displays solid green after decode.
Off when scan ended.
LED flashes red.
Table 3.3 Scan LED
3.6.1.4
User Application LED
This indicator is available for user-loaded custom Windows CE applications. Refer
to the 7535 SDK Manual for details about this LED. Neither Windows CE nor
Tekterm use this LED.
44
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
Onscreen Indicators
3.6.2 Onscreen Indicators
The taskbar at the bottom of the screen displays a variety of system status indicators.
Figure 3.7 Taskbar
This display changes dynamically, and only those icons that are applicable are
displayed. For example, if a radio is not installed in your 7535, the radio signal icon
is not displayed in the taskbar.
Windows® Start Button
If you have a touchscreen, you can display the Start Menu by tapping on the Windows®
Start button in the taskbar.
Psion Teklogix 7535 Hand-Held Computer User Manual
45
Chapter 3: Getting To Know Your 7535
Onscreen Indicators
Modifier Key Indicators
, , ,  and  are modifier keys that
have onscreen indicators to show when a key is active or locked. If a modifier key is
pressed once to activate it, the key is displayed in the taskbar in lowercase characters
– for example, pressing the  key once displays blue key in the taskbar. If a
modifier key is pressed twice, it is ‘locked on’ and the onscreen indicator is
displayed in uppercase letters in the taskbar – for example, pressing  twice
displays BLUE KEY in the taskbar.
Battery Gauge
The battery shaped icon displayed in the taskbar provides a visual indication of the
remaining battery power. The icon acts as a meter that is either full, at three-quarter
level, half, quarter level or empty.
When the battery level is low – approximately 15 minutes from empty – a warning
window pops up. When the battery power is completely depleted, a final warning
window indicates that the 7535 will be powered down.
If the 7535 is using external AC power, an AC icon is displayed in the taskbar.
Full
75%
50%
25%
Empty
AC Connection
Battery Charge
The battery charge icon is displayed in the taskbar when the 7535 hand-held battery
is being charged.
Radio Signal Quality
Increasing radio signal quality is represented by longer, filled bars within this icon.
Good
Reception
46
Psion Teklogix 7535 Hand-Held Computer User Manual
Weak
Reception
No Radio
Link
Chapter 3: Getting To Know Your 7535
Audio Indicators
Tethered Devices
When a peripheral is attached to the tether port and activated, an associated icon
appears in the taskbar. The sample to the left indicates that a USB device is
connected to the tether port.
Scanner
USB Device
RFID
Serial Device Scan-See
Docking Device
When a 7535 is inserted in a docking station, charger or cradle, an associated icon
appears in the taskbar.
Gang Charger, Combo Charger &
Combo Docking Station
Quad Docking Station
Power Cradle
Portable Docking
Module (PDM)
Security Level
Security levels can be set to limit user access to 7535 settings. In addition,
applications can be restricted to prevent inadvertent changes.
3.6.3 Audio Indicators
The 7535 beeper provides a variety of sounds and can be configured to emit a sound
when a key is pressed, a keyboard character is rejected, scan input is accepted or
rejected, an operator’s entry does not match in a match field or the battery is low.
The volume function keys are located in the top row of the keyboard. The increase
volume key is labelled with a plus symbol
and the decrease volume function
key is labelled with a minus symbol
Psion Teklogix 7535 Hand-Held Computer User Manual
47
Chapter 3: Getting To Know Your 7535
Adjusting The Beeper Volume
3.6.3.1
Adjusting The Beeper Volume
On 58-key keyboards, the volume function keys are accessed by pressing 
 and .
On 36-key keyboards, the volume function keys are accessed by pressing 
< F3> and .
To adjust the beeper volume:
•
•
Press the  key twice to lock the key ‘on’ and then, press the
increase volume function key
or the decrease volume
function
key until the volume is meets your requirements.
Remember to press the  key again to turn it ‘off’.
3.7 Internal Scanners
Important:
For detailed scanner specifications and decode zone tables, refer
to “Internal Scanner Specifications” beginning on page 281.
The scanner installed in your unit can be configured using the Scanner Properties
dialogue box in the Control Panel.
The 7535 can be equipped with a:
•
•
•
One dimensional (1D) internal laser scanner,
Internal PDF laser scanner, or a
Two dimensional (2D) internal imager scanner.
It is critical that you review the warnings listed in “Laser Warnings” on page xvi in
the Approvals and Safety section at the beginning of this manual before using any of
the scanners described in this chapter. “Scanning Techniques” outlines the
mechanics of a successful scan. In addition, review “Scan LED Indicators” on
page 49 to better understand how to interpret whether or not a bar code has been
successfully scanned. Finally, “Troubleshooting” on page 50 provides some helpful
suggestions should the scan fail.
48
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
Scanning Techniques
3.7.1 Scanning Techniques
Note: The scanning techniques described here apply to internal and external
scanners.
•
•
•
•
•
•
Hold the scanner at an angle. Do not hold it perpendicular to the bar code.
Do not hold the scanner directly over the bar code. In this position, light can
reflect back into the scanner’s exit window and prevent a successful decode.
Scan the entire bar code. If you are using a 1D or PDF laser scanner, make
certain that the scan beam crosses every bar and space on the bar code,
including the margins on either end of the symbol.
If you are using a 2D imaging scanner, make certain the red, oval shaped
framing mark is centered within the bar code you want to scan.
Hold the scanner farther away for larger bar codes.
Hold the scanner closer for bar codes with bars that are close together.
3.7.2 Scan LED Indicators
The 7535 scanner LED (the lower-left LED) indicates whether or not your scan is
successful. The LED behaves as follows:
•
•
•
Scan In Progress: scan LED displays solid red colour.
Successful Scan: scan LED displays solid green colour and turns off when
the scan is ended.
Unsuccessful scan: scan LED flashes red.
A bar code icon appears on the screen during a scan. While the scanner beam is
active, the onscreen message states – SCANNING. If the scan is successful, the bar
code data is displayed on the screen until the scan button (or pistol trigger) is
released.
Psion Teklogix 7535 Hand-Held Computer User Manual
49
Chapter 3: Getting To Know Your 7535
Troubleshooting
3.7.3 Troubleshooting
If the scanner is not working, investigate the following:
• Is the 7535 on?
• Check that the bar code symbology being scanned is enabled for the 7535
you are using. Check any other parameters that affect the scanning procedure or the bar code.
• Check the bar code to make sure it is not damaged. Try scanning a different
bar code to verify that the problem is not with the bar code.
• Check that the bar code is within the proper range.
• Does the hand-held display the warning without scanning? This suggests a
hardware problem in the 7535.
• Is the laser beam scanning across the bar code?
• Once the scan beam has stopped, check the scanner window for
dirt or fogging.
3.7.4 Operating One Dimensional (1D) Internal Laser Scanners
•
Turn the 7535 on. Wait until the unit has booted up completely.
Important:
•
50
If an aiming dot is available on the installed scanner, the dot will
be enabled for a configurable time period (including off), after
which normal scanning begins. Refer to “Dot Time (msec)” on
page 120 for details.
Double-clicking the trigger will override the aiming delay and
initiate an immediate scan. Note that the aiming dot is standard
on long-range and high visibility internal scanners.
Aim at the bar code and press the scan key or the trigger. A scan beam and a
warning indicator appear until a successful decode is achieved or six
seconds have elapsed.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
Operating Internal PDF Laser Scanners
3.7.5 Operating Internal PDF Laser Scanners
This scanner decodes PDF417 two-dimensional bar codes.
•
•
Turn the 7535 on. Wait until the unit has booted up completely.
Aim at the bar code and press the scan key or the trigger. The beam expands
into a rectangle covering the bar code to properly scan it. The scan beam
and a warning indicator are visible until a successful decode is achieved or
three seconds have elapsed.
3.7.6 Operating Internal Two Dimensional (2D) Imager Scanners
An imager scanner takes a snap shot of a single bar code or multiple bar codes (at
one time). It can find a bar code regardless of its orientation – that is, even a bar code
printed at a 45 degree angle to the 7535 will be decoded successfully.
Note: When scanning multiple bar codes, ensure that all of the desired bar
codes are within the field of view of the scanner. It is possible that even
when all bar codes are within the field of view, not all of them may be
decoded. Only successfully decoded bar codes are passed to the application program. The application program then issues a warning, asking that
you scan the missing bar codes.
When scanning a single bar code, ensure that only the desired bar code is
within the field of view of the scanner.
Because imager scanners generally have a shorter depth of field than laser scanners,
some practise may be required to find the optimal distance from the types of bar
codes being scanned. Although the imager includes illumination LEDs, ambient
light will help the imager decode the bar codes, especially if the bar code is far from
the 7535.
Important:
•
•
Keep in mind that the imager scanner is a camera, and the LED
illumination is a flash. Glare can be an issue on reflective media
such as plastic coated bar codes, just as glare is an issue for photographers. When pointing at a shiny surface, either shift the bar
code to the side or top, or angle the bar code so that the glare
reflects away from the imager scanner.
Turn the 7535 computer on. Wait until the unit has booted up completely.
Aim at the bar code and press the scan key or the trigger.
Psion Teklogix 7535 Hand-Held Computer User Manual
51
Chapter 3: Getting To Know Your 7535
Connecting & Disconnecting Tethered Peripherals
•
When the scan button or trigger is pressed, a red, oval shaped light (the
framing marker) is displayed. Centre the framing marker in the field – either
in the centre of the bar code you want to scan or in the centre of the area in
which multiple bar codes are to be scanned.
Illumination LEDs will flash and a picture of the bar code(s) is taken.
3.8 Connecting & Disconnecting Tethered Peripherals
Tethered peripherals such as scanners and printers connect to the hand-held
computer with a quick release, circular connector. When a peripheral is connected to
the hand-held, the 7535 detects the peripheral and loads the necessary drivers for it.
An icon in the taskbar at the bottom of the screen provides a visual representation of
the peripheral and indicates that it is ready for operation.
To attach the peripheral to the round, tether port on the side of the 7535:
•
Insert the barrel of the plug into the tether port and rotate slowly until
it clicks into place. The red dot on the port and on the connector should
be aligned.
Figure 3.8 Attaching The Cable To The Tether Port
52
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
Monitoring The Battery And Maximizing Run Time
To remove the peripheral:
•
Grasp the shell of the plug, and pull it back gently to unlock and release the
connector.
Figure 3.9 Disconnecting The Tether Cable
Important:
Never attempt to disconnect a peripheral by pulling the connector
by the wire. The connector is locked into place and can only be
unlocked and removed by pulling back the plug shell.
3.9 Monitoring The Battery And Maximizing Run Time
Under normal operating conditions, fully charged batteries last for 10 hours. As
Lithium-Ion batteries age, their capacity decreases gradually, and they are generally
considered depleted after approximately 2 years of use (less than 60% of original
capacity remaining). Keep in mind however that heavy usage or operating the 7535
at temperature extremes will shorten the battery life.
Lithium-Ion batteries do not require conditioning cycles and the 7535 battery
system (including chargers) requires no user interaction to maintain peak
performance.
Psion Teklogix 7535 Hand-Held Computer User Manual
53
Chapter 3: Getting To Know Your 7535
Monitoring The Battery And Maximizing Run Time
To maximize the run time of your batteries, consider the following:
•
•
•
The display backlight is the largest drain on the battery. Try to keep its
brightness as low as possible.
The hand-held is ‘event’ driven – that is, when the unit is not in use, it
reverts to sleep mode (even when it appears to be running), saving battery
power. Events include a key press, touchscreen taps and scan triggers.
Power consumption is reduced if you avoid unnecessary events, and allow
the unit to sleep as much as possible.
The 7535 battery is a ‘smart battery’ with built-in intelligence. The taskbar
battery icon is a linear gauge used to estimate the remaining run time of the
battery. It is important to note that the battery capacity icon displays quarter
percentages of nominal capacity (the capacity of a new battery). An aged
battery, even when fully charged, shows somewhat less capacity than
nominal.
Double-tapping on the battery icon displays a dialogue box that provides
detailed information about the battery status and performance. If the
remaining capacity indication seems inaccurate, the battery may need recalibration. Recalibration requires that the battery be fully charged, discharged
and then charged again before use. If the battery is fully discharged and
charged on a regular basis, recalibration should not be necessary.
•
•
•
54
When the hand-held is switched off, it goes into a low-power, suspend state
but continues to draw a small amount of power from the battery. This
should not be an issue unless the unit is left in suspend state for more than a
week – in this case, the battery should be removed.
Batteries left unused for durations of more than one or two months should
be fully charged, discharged and then charged again before use. This recalibrates the gas gauge and allows the internal electronics to determine the
actual capacity of the battery.
The hand-held can determine when the useful life of the battery has expired
and will notify the user. Chargers may reject batteries that have exceeded
their lifespan.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
Storing Batteries
3.9.1 Storing Batteries
Long term battery storage is not recommended. If storage is necessary:
•
•
•
•
•
Always try to use a ‘first-in first-out’ approach to minimize storage time.
Lithium-Ion batteries age much faster at elevated temperatures. Store batteries at temperatures between 0˚ C and 20˚C.
Always charge batteries to 40 to 60% before storing them. Batteries can be
damaged by an over-discharge phenomenon that occurs when an empty
battery is stored for a long period of time such that the cell voltage drops
below a lower limit.
To minimize storage degradation, recharge stored batteries to 40 to 60%
every 4 or 6 months to prevent over-discharge damage.
A ‘never used’ Li-Ion battery that has been stored for 3 years may have
limited or no useful life remaining once put into service. Think of batteries
as perishable goods.
3.10 Monitoring The Network Connection
If your hand-held is equipped with a wireless LAN radio, it will typically associate
with the nearest access point. The radio signal quality meter in the taskbar indicates
the relative strength of the communication link.
To access the radio signal icon from the keyboard:
•
•
•
•
Press  <0> to display the Start Menu.
Choose System Tray from the menu.
Use the  and  arrow keys to highlight the radio signal
icon in the taskbar.
Press  to display the wireless statistics box dialogue box.
If you have a touchscreen:
•
Tap on the radio icon in the taskbar to display the wireless statistics
dialogue box.
Note: Moving in and out of the radio coverage area can have varying effects on
a network session. At times, you may need to renew your connection by
logging in again.
Psion Teklogix 7535 Hand-Held Computer User Manual
55
Chapter 3: Getting To Know Your 7535
Uploading Data In A Docking Station
3.11 Uploading Data In A Docking Station
The Combo Docking and Quad Docking peripherals allow the 7535 to link to an
Ethernet network. They are typically used to upload transaction data to a server
computer when a radio link in not available. When a 7535 is properly inserted in a
docking station, a dock icon is displayed in the taskbar at the bottom of the 7535
screen. The 7535 also detects the presence of the Ethernet network. Review the
documentation provided with the user application installed in your 7535 before
preforming data uploads.
3.12 General Maintenance
3.12.1 Caring For The Touchscreen
The top of the touchscreen is a thin, flexible polyester plastic sheet with a
conductive coating on the inside. The polyester can be permanently damaged by
harsh chemicals and is susceptible to abrasions and scratches. Using sharp objects
on the touchscreen can scratch or cut the plastic, or crack the internal conductive
coating.
The chemicals listed below must not come into contact with the touchscreen:
•
•
•
•
•
mustard,
sodium hydroxide,
concentrated caustic solutions,
benzyl alcohol, and
concentrated miner acids.
If the touchscreen is used in harsh environments, consider applying a disposable
screen protector (PN HU6110). These covers reduce the clarity of the display
slightly but will dramatically extend the useful life of the touchscreen. When they
become scratched and abraded, they are easily removed and replaced.
56
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 3: Getting To Know Your 7535
Cleaning The 7535
3.12.2 Cleaning The 7535
Important:
•
•
•
Do not immerse the unit in water. Dampen a soft cloth with mild
detergent to wipe the unit clean.
Use only mild detergent or soapy water to clean the hand-held unit.
Avoid abrasive cleaners, solvents or strong chemicals for cleaning. The
7535 has a plastic case that is susceptible to harsh chemicals. The plastic is
partially soluble in oils, mineral spirits and gasoline. The plastic slowly
decomposes in strong alkaline solutions.
To clean ink marks from the keypad and touchscreen, use isopropyl
alcohol.
Psion Teklogix 7535 Hand-Held Computer User Manual
57
4
WORKING WITH WINDOWS CE
4.1 Navigating In Windows CE And Applications . . .
4.1.1 Navigating Using A Touchscreen And Stylus
4.1.2 Navigating Using The Keyboard . . . . . . .
4.2 Working With Files, Folders And Programs . . . .
4.3 The Startup Desktop . . . . . . . . . . . . . . . .
4.3.1 The Desktop Icons . . . . . . . . . . . . . .
4.3.2 The Taskbar . . . . . . . . . . . . . . . . . .
4.3.2.1 Using The Taskbar . . . . . . . . . .
4.3.2.2 Customizing The Taskbar . . . . . .
4.4 The Start Menu . . . . . . . . . . . . . . . . . . .
4.4.1 The Desktop . . . . . . . . . . . . . . . . .
4.4.2 Security Settings . . . . . . . . . . . . . . .
4.4.3 The System Tray . . . . . . . . . . . . . . .
4.4.4 The Task Manager . . . . . . . . . . . . . .
4.4.5 Cycle Tasks . . . . . . . . . . . . . . . . . .
4.4.6 Power Info . . . . . . . . . . . . . . . . . .
4.4.7 Programs . . . . . . . . . . . . . . . . . . .
4.4.8 Settings . . . . . . . . . . . . . . . . . . . .
4.4.9 Run . . . . . . . . . . . . . . . . . . . . . .
4.4.10 Shutdown . . . . . . . . . . . . . . . . . .
4.5 Using A Dialogue Box . . . . . . . . . . . . . . .
61
61
62
63
64
65
66
66
67
68
68
69
70
71
71
71
72
73
74
75
76
Psion Teklogix 7535 Hand-Held Computer User Manual
59
Chapter 4: Working With Windows CE
Navigating In Windows CE And Applications
4.1 Navigating In Windows CE And Applications
Graphic user interfaces like Windows CE for portable devices and desktop Windows
(2000, XP, etc.) utilize ‘point and click’ navigation. An equivalent keyboard shortcut
is also available for every ‘point and click’ action.
Windows CE supports the same ‘point and click’ user interface and keyboard
shortcuts as desktop Windows with one difference – the ‘point and click’ action is
accomplished using a touchscreen rather than a mouse. Actions can be performed
using any combination of keyboard shortcuts or touchscreen tapping (provided your
7535 is equipped with a touchscreen).
4.1.1 Navigating Using A Touchscreen And Stylus
Note: If the touch screen is not registering your screen taps accurately, the
touchscreen may need recalibration. Refer to “Calibrating The Touchscreen” on page 41.
A touchscreen is an optional feature. A 7535 equipped with a touchscreen has a
stylus – a pointing tool that looks like a pen – stored in a slot at the top of the 7535.
The stylus is used to select objects on the touchscreen.
Note: To prevent damage to the touchscreen, use only the stylus (pen)
supplied with your 7535.
To open a file, launch an applet or open a folder:
•
Double-tap the stylus on the appropriate icon.
Psion Teklogix 7535 Hand-Held Computer User Manual
61
Chapter 4: Working With Windows CE
Navigating Using The Keyboard
4.1.2 Navigating Using The Keyboard
If your 7535 has a standard screen (rather than a touchscreen), choosing icons and
navigating dialogue boxes, displaying the desktop, and so on requires keyboard
input. If your unit has already been fully configured and your application is
launched at startup, you’ll have little need for keyboard navigation.
Operation
Key or Key Combination
Switch between active applications
Open task manager
Move the cursor
Open file, folder or icon
Exit & Save
Close/Exit & Do Not Save
Navigate Dialogue Boxes
Select Radio Button/Press Button
Go to Start Menu
 
 
Arrow keys




To move cursor up  
To display the contents of the next ‘tab’ in
a dialogue box  

<0>
Table 4.1 Keyboard Navigation
Keep in mind that unlike a desktop computer, the 7535 does not support key
chording (pressing two keys at the same time). You must press one key followed by
the next in sequence.
Refer to “Working With Files, Folders And Programs” on page 63 for additional
details about keyboard navigation.
62
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Working With Files, Folders And Programs
4.2 Working With Files, Folders And Programs
Folder
Program Icon
File
Figure 4.1 Working With Windows Icons
•
•
Use the arrow keys to highlight the icon you want to open or launch.
Press .
If you have a touchscreen:
•
Double-tap on the appropriate icon – either a folder icon, a program icon or
a file icon – to open or launch your selection.
Psion Teklogix 7535 Hand-Held Computer User Manual
63
Chapter 4: Working With Windows CE
The Startup Desktop
4.3 The Startup Desktop
When the 7535 boots up, the startup desktop (shell) is displayed. Any applications
stored in the Startup folder start up immediately.
Note: The startup folder is located in \Windows\StartUp and
\Flash Disk\StartUp.
Figure 4.2 The 7535 Startup Desktop
To access desktop icons:
•
Use the arrow keys to highlight the icon, and press  to launch the
highlighted icon.
Note: If the arrow keys do not highlight the desktop icons, the desktop may not
be selected. Press  0 (zero) to display the Start Menu, and select
Desktop. Now the desktop will be “in focus” and the arrow keys will highlight the icons.
If you have a touchscreen:
•
64
Tap on the icon to open a window or, in the case of an application icon,
launch an application.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
The Desktop Icons
4.3.1 The Desktop Icons
The icons displayed in the startup desktop operate in much the same way as those
displayed on any standard PC desktop that is running Windows®.
My Computer
Choosing this icon displays the contents of your 7535 computer. If you’re not sure
how to work with the files, folders and programs displayed, refer to “Working With
Files, Folders And Programs” on page 63.
Recycle Bin
This option temporarily contains items that were deleted, allowing you to either
permanently delete or restore these items.
Internet Explorer
Choosing this icon launches Internet Explorer – a standard Windows CE version.
Keep in mind that your supervisor will need to set up access using the Internet Options
and the Network and Dial-up Connections icons in the Control Panel.
Remote Desktop Connection
This option allows your 7535 to communicate with a remote desktop PC. “Remote
Desktop Connection” on page 83 provides a website with step-by-step instructions.
Psion Teklogix 7535 Hand-Held Computer User Manual
65
Chapter 4: Working With Windows CE
The Taskbar
4.3.2 The Taskbar
Figure 4.3 The Taskbar
The 7535 is equipped with a taskbar at the bottom of the screen. It displays icons
through which you can view the battery capacity and radio signal quality of your
unit. If the hand-held is attached to a charger, cradle, docking station or PDM, an
associated icon is displayed. In addition, the taskbar displays the application(s)
currently running on your unit and the security level assigned to your 7535.
The taskbar also displays active modifier keys – , , ,
 and . Keys that have been locked “on” are displayed in
uppercase letters. For example, if you press the  key twice to lock it “on”, it
is displayed as CTRL KEY in the taskbar.
4.3.2.1
•
•
•
•
Using The Taskbar
Press  <0> to display the Start Menu.
Type  to choose System Tray from the menu.
Use the arrow keys to highlight the icon in the taskbar about which you’d
like more information.
Press  to display the appropriate dialogue box.
If you have a touchscreen:
•
66
Using the stylus, tap on the indicator you want to view – the battery icon for
example – to display a dialogue box listing the current battery capacity
information.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Customizing The Taskbar
4.3.2.2
Customizing The Taskbar
To customize the taskbar so that it displays only those icons you require:
•
•
Press  <0> (zero) to display the Start Menu.
Highlight the Settings option, highlight Taskbar... in the sub-menu, and
press .
The Taskbar and Start Menu dialogue box is displayed.
Figure 4.4 Taskbar And Start Menu Settings
•
Under the General tab, highlight the options you want to activate, and press
the  key to select them. A check mark indicates active items.
If you have a touchscreen:
•
Tap the stylus on the items you want to activate or deactivate. The check
mark indicates active items.
Psion Teklogix 7535 Hand-Held Computer User Manual
67
Chapter 4: Working With Windows CE
The Start Menu
4.4 The Start Menu
Note: Some of the Start Menu items may be disabled based on the 7535’s
current security settings.
The Start Menu lists the operations you can access and work with. It is available from
the startup desktop or from within any application.
To display the menu:
• Press  <0> (zero).
Figure 4.5 Start Menu
•
Use the arrow keys to highlight a menu item, and press , or
If the menu item has an underlined character:
•
Type the underlined alpha character – for example, to display the Power
Info dialogue box, type the letter p.
If you have a touchscreen:
•
Tap on the Windows® Start button in the taskbar. Tap on the item in the
menu with which you want to work.
4.4.1 The Desktop
Choosing the Desktop option from the Start Menu displays the 7535 desktop.
68
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Security Settings
4.4.2 Security Settings
Choosing the Security option from the Start Menu displays a dialogue box in
which you can define the access level for the 7535 – Teklogix, Supervisor or User.
Figure 4.6 Security Levels
Security Level
These security levels define the options accessible to the operator in the Start Menu
and the taskbar. When you change security levels, you’ll need to enter the
appropriate password in the Password textbox. The security level is represented by an
icon in the shape of a lock in the taskbar.
Changing A Password
Note: Keep in mind that this is the same password as that assigned through the
Password control panel applet. Refer to “Control Panel Icons” on page 84.
To assign a password:
•
•
Choose a security level, and enter the existing password in the Password field
Choose the Set Password button.
A dialogue box labelled Password Properties is displayed.
•
•
Type the new password in the Password: text box
In the Confirm Password: text box, retype the new password.
Psion Teklogix 7535 Hand-Held Computer User Manual
69
Chapter 4: Working With Windows CE
The System Tray
Configuring Security
Choosing the Configure button displays the Configure Security dialogue box.
Figure 4.7 Configuring Security
This dialogue box allows you to determine which security levels will have an
associated icon displayed in the taskbar. By default, a security icon is not displayed
for user-level security.
4.4.3 The System Tray
The System Tray option allows access to the icons in the taskbar at the bottom
of the screen. The taskbar displays indicators such as a battery capacity gauge and
the security level. These indicators are attached to dialogue boxes that provide
additional information.
• Choose System Tray from the Start Menu.
When System Tray is chosen, the taskbar icons become accessible. To display
the dialogue box attached to an icon:
•
•
Use the arrow keys to highlight an icon – for example – the security icon.
Press  to display the security level dialogue box.
If you have a touchscreen:
•
70
Tap on the icon with which you want to work. The associated dialogue box
is displayed.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
The Task Manager
4.4.4 The Task Manager
The Task Manager option allows you to switch to another task or to end an
active task. To display the task manager window:
•
•
Press <0>, or
Press  .
Figure 4.8 Task Manager
4.4.5 Cycle Tasks
When Cycle Tasks is selected (and the Task Manager is not open), you can
cycle through active applications. To choose this option:
•
•
Press <0>, and type , or
Press  .
4.4.6 Power Info
Selecting Power Info from the Start Menu displays the Power Properties dialogue box.
This dialogue box indicates the remaining charge capacity of the battery.
Psion Teklogix 7535 Hand-Held Computer User Manual
71
Chapter 4: Working With Windows CE
Programs
4.4.7 Programs
With Programs highlighted, press the  arrow key to display a
sub-menu of options.
Figure 4.9 Program Sub-Menu
This sub-menu allows you to choose ActiveSync and Command Prompt, and you can access
the Internet Explorer, installed applications (e.g., Open Tekterm), Remote Desktop Connection or
Windows Explorer.
ActiveSync®
This option allows you to connect to another device using ActiveSync.
Command Prompt
Command Prompt is used to access the DOS command prompt. At the prompt, you can
type DOS commands such as dir to display all the directories in the drive.
Internet Explorer
The 7535 is equipped with Microsoft® Internet Explorer consistent with all
Windows CE devices on the market. You can access the Internet Options icon through
the Start Menu under Settings>Control Panel or by double-tapping on the
desktop icon labelled My Computer and then, double-tapping on the Control Panel icon.
72
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Settings
Windows Explorer
Windows Explorer installed on your 7535 is consistent with all Windows CE.NET 4.2
devices. You can access this option either from the Start Menu under
Programs>Windows Explorer.
Remote Desktop Connection
Remote Desktop Connection is a 7535 application used to connect to a Windows Terminal
Server so that you can run a “session” on the Server machine using the 7535
(Windows CE device). “Remote Desktop Connection” on page 83 provides a
website with details about this option.
4.4.8 Settings
With Settings highlighted, pressing the  arrow key displays a
sub-menu of options, including Control Panel, Network and Dial-up Connections and Taskbar and
Start Menu settings.
Figure 4.10 Settings Sub-Menu
Control Panel
The Control Panel contains applets used to configure hardware, the operating system
and the shell. If your 7535 is running with the Psion Teklogix Tekterm application or
another application, additional configuration applets may appear in the Control Panel.
Psion Teklogix 7535 Hand-Held Computer User Manual
73
Chapter 4: Working With Windows CE
Run
Network And Dial-Up Connections
The Network and Dial-up Connections window allows you to configure the 7535 radio or
execute an existing configuration. Refer to “Configuring An IEEE 802.11 Radio
Installed In The 7535” on page 18 for radio setup details.
Taskbar And Start Menu
The Taskbar and Start Menu option displays a dialogue box in which you can
customize the taskbar, choosing which options will be displayed. Refer to
“Customizing The Taskbar” on page 67 for additional details about this option.
4.4.9 Run
Choosing the Run option from the Start Menu displays a dialogue box in which you
can enter the name of the program, folder or document you want to open or launch.
Figure 4.11 Run Dialogue Box
74
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Shutdown
4.4.10 Shutdown
With Shutdown highlighted, pressing the  arrow key displays a
sub-menu of options, including Suspend, Warm Reset and Cold Reset.
Figure 4.12 Shutdown Sub-Menu
Note: This menu varies slightly depending on the security level chosen. When
the 7535 is set to User level, the Shutdown option is replaced by Suspend.
A sub-menu is not available.
At Teklogix security level, an additional option is available in the
sub-menu – Bootloader. This option behaves like cold-reset, except
that the 7535 starts Bootloader rather than Windows CE.
Suspend
The Suspend option suspends the 7535 immediately – this is equivalent to turning the
hand-held off.
Warm Reset
The Warm Reset option resets the 7535, leaving all saved files and (registry) settings
intact. Any unsaved data is lost.
Cold Reset
The Cold Reset option resets the 7535. Any files not stored in permanent memory are
lost. However, the registry settings are saved.
Psion Teklogix 7535 Hand-Held Computer User Manual
75
Chapter 4: Working With Windows CE
Using A Dialogue Box
4.5 Using A Dialogue Box
A dialogue box (like the samples in Figure 4.13) appears when you need to make
selections and enter further information.
You can move between dialogue items by tapping on them, or by pressing the arrow
keys and the  key. (  moves the cursor backwards.)
Tabs
Radio
Button
Textbox
Dropdown Menu
Checkbox
Button
Figure 4.13 Dialogue Boxes
Note: If your unit is equipped with a touchscreen, you can use the stylus to tap
on an element in a dialogue box to select or deselect it, display dropdown
menu items, save your selections, and so on.
Dialogue boxes contain one or more of the following elements:
Tab: A tab separates different elements of a dialogue box. Press the  key
until a tab in the dialogue box is highlighted. To display adjoining tabs, press the
 or  arrow key. To display the information in the next tab from
anywhere in the window, press  .
Textbox: A textbox requires that you type information. Press the  key to
highlight the textbox and then type the appropriate information.
Dropdown: This type of menu is identified by up and down arrows next to the
dropdown menu to indicate that additional options are available. Press the 
key to highlight the menu, and use the arrow keys on your keyboard to cycle through
the options.
76
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 4: Working With Windows CE
Using A Dialogue Box
Checkbox: This box allows you to select or deselect an option. To select or deselect
a checkbox, press the  key to highlight the checkbox, and press the
 key to select (√) or deselect it.
Radio buttons: These buttons allow you to choose from a number of options. For
example, in the sample screen in Figure 4.13 on page 76 you can choose to ‘Obtain an
IP address via DHCP’ or ‘Specify an IP address’. Press the  key to highlight a radio
button option, and then select a radio button by pressing the arrow keys to highlight
the appropriate option.
Buttons: This type of button allows you to ‘Save’, ‘Delete’ and so on the options
you’ve chosen in a dialogue box. Use the  key to highlight the button you
want to use. Press the  key to activate it.
Saving Your Choices: Once you’ve made all your changes, press the 
key to save your changes and exit the window.
Note: A dialogue box item that is displayed in grey text indicates that it is not
currently available.
Psion Teklogix 7535 Hand-Held Computer User Manual
77
5
CONFIGURATION
5.1
5.2
5.3
5.4
5.5
Remote Desktop Connection . . . . . . . . .
Pocket PC Compatibility . . . . . . . . . . .
The Control Panel . . . . . . . . . . . . . . .
Control Panel Icons . . . . . . . . . . . . . .
Basic Setup . . . . . . . . . . . . . . . . . .
5.5.1 Display Properties . . . . . . . . . . .
5.5.1.1 Display Contrast . . . . . . . .
5.5.1.2 Display Backlight . . . . . . .
5.5.1.3 Display Appearance . . . . . .
5.5.2 Keyboard Properties . . . . . . . . . .
5.5.2.1 Key Repeat. . . . . . . . . . .
5.5.2.2 Keyboard Backlight . . . . . .
5.5.2.3 Keyboard One Shot Modes . .
5.5.2.4 Keyboard Macro Keys . . . . .
5.5.2.5 Unicode Mapping . . . . . . .
5.5.3 Volume And Sound Properties . . . . .
5.5.3.1 Volume Adjustments . . . . . .
5.5.4 Power Management Properties . . . . .
5.5.4.1 Battery Capacity . . . . . . . .
5.5.4.2 Power Saving Schemes . . . .
5.5.4.3 Suspend Threshold. . . . . . .
5.5.4.4 Charger Details . . . . . . . .
5.5.5 Stylus Properties . . . . . . . . . . . .
5.5.5.1 Setting Double-Tap Sensitivity
5.5.5.2 Touchscreen Calibration . . . .
5.5.6 Certificate Assignment . . . . . . . . .
5.7 Scanner Properties Setup . . . .
5.7.1 Scanner Options . . . . .
5.7.2 Bar Codes . . . . . . . . .
5.7.2.1 Code 39 Settings .
5.7.2.2 Code 128 Settings
. 83
. 83
. 83
. 84
. 88
. 88
. 88
. 89
. 91
. 92
. 92
. 93
. 94
. 95
. 97
. 99
. 99
100
100
101
102
103
103
104
104
105
118
118
121
122
124
Psion Teklogix 7535 Hand-Held Computer User Manual
79
Chapter 5: Configuration
5.7.2.3 EAN 13 Settings . . . . . . . . . . . . .
5.7.2.4 EAN 8 . . . . . . . . . . . . . . . . . .
5.7.2.5 UPC And EAN Settings . . . . . . . . .
5.7.2.6 UPC A Settings. . . . . . . . . . . . . .
5.7.2.7 UPC E Settings . . . . . . . . . . . . . .
5.7.2.8 Codabar. . . . . . . . . . . . . . . . . .
5.7.2.9 Code 93. . . . . . . . . . . . . . . . . .
5.7.2.10 Code 11 . . . . . . . . . . . . . . . . .
5.7.2.11 Interleaved 2 of 5 . . . . . . . . . . . .
5.7.2.12 MSI Plessey . . . . . . . . . . . . . . .
5.7.2.13 Discrete 2 of 5 . . . . . . . . . . . . .
5.7.2.14 IATA 2 of 5 . . . . . . . . . . . . . . .
5.7.2.15 Postal: Australian . . . . . . . . . . . .
5.7.2.16 Postal: Japanese . . . . . . . . . . . . .
5.7.2.17 Postal: Korean. . . . . . . . . . . . . .
5.7.2.18 Postal: PlaNET . . . . . . . . . . . . .
5.7.2.19 Postal: PostNET. . . . . . . . . . . . .
5.7.2.20 Postal: Royal Mail . . . . . . . . . . .
5.7.2.21 2D DataMatrix . . . . . . . . . . . . .
5.7.2.22 2D Maxicode . . . . . . . . . . . . . .
5.7.2.23 2D PDF-417. . . . . . . . . . . . . . .
5.7.2.24 2D Micro PDF-417 . . . . . . . . . . .
5.7.2.25 2D QR Code . . . . . . . . . . . . . .
5.7.2.26 2D RSS Code . . . . . . . . . . . . . .
5.7.2.27 Aztec . . . . . . . . . . . . . . . . . .
5.7.3 Translations . . . . . . . . . . . . . . . . . . . .
5.8 SNMP (Simple Network Management Protocol) Setup.
5.8.1 Contact Tab . . . . . . . . . . . . . . . . . . . .
5.8.2 Communities Tab . . . . . . . . . . . . . . . . .
5.8.2.1 Adding A Community . . . . . . . . . .
5.8.2.2 Modifying A Community Setting . . . .
5.8.2.3 Removing An Existing Community . . .
5.8.3 Trap Destination Tab . . . . . . . . . . . . . . .
5.8.3.1 Enabling Authentication TRAPS. . . . .
5.8.3.2 Adding A Destination . . . . . . . . . .
5.8.3.3 Changing A Destination . . . . . . . . .
5.8.3.4 Removing A Trap Destination . . . . . .
80
Psion Teklogix 7535 Hand-Held Computer User Manual
125
126
127
127
127
128
128
128
129
129
129
130
130
130
130
131
131
131
131
131
131
132
132
132
132
132
134
135
136
137
138
138
139
139
139
140
140
Chapter 5: Configuration
5.8.4 Permitted Hosts Tab . . . . . . . . . . . . . . . . . . . . . . . . 141
5.8.4.1 Adding A Host . . . . . . . . . . . . . . . . . . . . . . . 141
5.8.4.2 Changing A Host. . . . . . . . . . . . . . . . . . . . . . 142
Psion Teklogix 7535 Hand-Held Computer User Manual
81
Chapter 5: Configuration
Remote Desktop Connection
5.1 Remote Desktop Connection
Remote Desktop Connection is a 7535 application used to connect to a Windows Terminal
Server so that you can run a “session” on the Server machine, using the 7535
(Windows CE device).
Refer to the following website for step-by-step information about setting up this
connection:
http://www.microsoft.com/WindowsXP/pro/using/howto/gomobile/remotedesktop/default.asp
5.2 Pocket PC Compatibility
The 7535 supports the AYGShell API set that allows PocketPC-compatible
applications to run on the hand-held. Microsoft® Windows® CE.NET 4.2 is
designed to include application programming interface (API) compatibility support
for the Microsoft Windows Powered Pocket PC 2002 shell in 7535s running
Windows® CE.NET 4.2.
The website listed below describes the APIs exposed through AYGShell and the
application compatibility between Windows Powered Pocket PC 2002-based
applications and Windows CE.NET 4.2-based devices:
http://msdn.microsoft.com/library/default.asp?url=/library/en-us/dncenet /html/WINCENET_CEPCC_App.asp
5.3 The Control Panel
The Windows CE Control Panel provides a group of icons through which you can set a
variety of system-wide properties, such as mouse sensitivity, network configuration
and the desktop color scheme.
Note: If you are uncertain how to move around a dialogue box and make selections, review “Using A Dialogue Box” on page 76.
When the 7535 boots up, the startup desktop (shell) is displayed, and any
applications stored in the Startup folder start up immediately.
To access the Windows CE Control Panel:
•
•
•
Press BLUE> <0> to display the Start Menu.
Highlight Settings in Start Menu, and press the  arrow key to
highlight the Control Panel option.
Press the  key to display the contents of the Control Panel window.
Psion Teklogix 7535 Hand-Held Computer User Manual
83
Chapter 5: Configuration
Control Panel Icons
If you have a touchscreen:
•
Use the stylus to tap on the Windows Start button in the taskbar to display the
Start Menu. Tap on Settings>Control Panel.
The Control Panel folder contains icons used in the setup of your 7535.
Figure 5.1 Control Panel
5.4 Control Panel Icons
The Windows CE Control Panel provides a group of icons that allow you to customize
and adjust settings on your 7535.
Date/Time
Allows you to set the current Month, Date, Time and Time Zone on your
unit.
Display
Changes the appearance (window colour scheme) on the unit desktop.
Keyboard
Toggles character repeat on and off and specifies delay and rate for repeated
characters. It also allows you to adjust the keyboard backlight threshold and
intensity.
84
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Control Panel Icons
Volume & Sound
Allows you to adjust the volume of the beep that is emitted to indicate
events like warnings, key clicks and, if your unit is equipped with a touchscreen, screen taps.
Sounds (wave files) cannot be reproduced on 7535 units. The beeper
volume and the conditions under which it sounds are tailored from within
the application installed on your unit.
Mouse Properties
For units equipped with touchscreens, this icon allows you to customize the
sensitivity and speed of the stylus double-tap.
Owner
Provides fields in which you can specify owner information. A ‘Notes’ tab
allows additional information to be entered and displayed when the unit is
powered up. ‘Network ID’ tab information is used to access network resources.
(This information should be provided by your System Administrator.)
Password
Allows you to assign a password to restrict access to elements of the unit.
Once assigned, password access cannot be circumvented so it is important
that you write down your password and keep it in a safe place. Refer to
“Security Settings” on page 69 for details.
Power
Displays battery pack power status. (Alternately, battery status can be
accessed through the taskbar.) The ‘Power Scheme’ tab allows you to determine a suspend states, and the ‘Charger’ tab determines whether or not a
battery that requires it, can be recalibrated. (Refer to “Power Saving
Schemes” on page 101 for details.)
Psion Teklogix 7535 Hand-Held Computer User Manual
85
Chapter 5: Configuration
Control Panel Icons
Regional Settings
Allows you to specify the local language the display text will use along
with the format of numbers, currency, time and date for your region.
Remove Programs
Lists the programs that can be removed from your unit. To remove a program, select it and then click on the Remove button.
Stylus
Adjusts how Windows CE recognizes your double-tap (as slow or rapid
successive taps).
Under the ‘Calibration’ tab, you can recalibrate your touchscreen by tapping
on the ‘Recalibrate’ button and following the directions on the calibration
screen.
System
Displays system and memory properties. Under the Memory tab, you can
allocate memory between storage memory and program memory.
Dialing
Specifies dialing settings, including area code, country code, dial type and
the code to disable call waiting. You can store multiple patterns – for example, ‘Work’, ‘Home’, and so on using this dialogue box.
Certificates
A public key is transmitted as part of a certificate. The certificate assigned
through this icon is used to ensure that the submitted public key is, in fact,
the public key that belongs to the submitter. The client checks that the certificate has been digitally signed by a certification authority that the client
explicitly trusts. “Certificate Assignment” on page 105 directs you to the
appropriate setup information.
86
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Control Panel Icons
PC Connection
Enables direct connections to a desktop computer. Selecting the ‘Change Connection’ button allows you to change the type of direct connect to your PC.
Teklogix Scanners
Used to set up scanner parameters and choose the bar code symbologies
that the 7535 scanner will successfully read.
Network And Dial-up Connections
Displays a network window from which the 7535 radio can be configured
and an existing configuration can be executed. Refer to “Configuring An
IEEE 802.11 Radio Installed In The 7535” on page 18 for details.
Internet Options
Used to configure your Internet browser including options such as identifying the default and search page that the browser applies when connecting to
the Internet, setting the cache size, specifying the Internet connection
options, and defining the security level that is applied when browsing.
SNMP
SNMP (Simple Network Management Protocol) is the protocol used to
monitor and manage devices attached to a TCP/IP network.
Input Panel
The 7535 is equipped with the framework for a Soft Input Panel (SIP)
should you need to design your own SIP.
Psion Teklogix 7535 Hand-Held Computer User Manual
87
Chapter 5: Configuration
Basic Setup
5.5 Basic Setup
5.5.1 Display Properties
•
In the Control Panel, choose the Display icon.
Figure 5.2 Choosing The Display Icon
5.5.1.1
Display Contrast
The Contrast tab allows you to adjust the 7535 display contrast to suit the environment
in which you are using the hand-held.
88
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Display Backlight
•
In the Display Properties dialogue box, open the Contrast tab.
Figure 5.3 Display Contrast Properties
Sliding bar in the Contrast tab to the left decreases or darkens the display contrast.
Sliding the bar to the right to increases or lightens the display contrast.
5.5.1.2
Display Backlight
The backlight is activated for a configurable amount of time if the ambient light is
below a specified threshold and if the 7535 is in use (key press, scanner trigger or
data received from the host). The Display Properties dialogue box in the Control Panel
allows you to specify the intensity of the backlight along with how the backlight
behaves in low-light conditions and when the unit is not in use.
Note: Keep in mind that this option may be restricted to supervisory use only.
Psion Teklogix 7535 Hand-Held Computer User Manual
89
Chapter 5: Configuration
Display Backlight
•
In the Display Properties dialogue box, open the Backlight tab.
Figure 5.4 Display Backlight Properties
Note: Backlight changes take affect immediately. You do not need to reset
the 7535.
ON Threshold
The 7535 is equipped with an ambient light sensor. This sliding bar allows you to
determine how dark the ambient light needs to be before the backlight turns on.
Intensity
This parameter is used to adjust the light intensity of the 7535 backlight. Sliding the
bar to the left lowers the light intensity, and sliding it to the right raises the intensity.
Bright For
The value chosen from this dropdown menu determines the duration of time that the
backlight stays on at the configured intensity when a unit is not in use.
Dim For
The value chosen from this dropdown menu determines the duration of time that
the backlight stays on at half the configured intensity (dimmed backlight) when a
unit is not in use.
90
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Display Appearance
External Power Checkbox
When you select (√) the checkbox next to ‘When using external power keep the backlight
always ON.’, the backlight remains ON at the configured intensity when the 7535 is
operating with external power (not battery power). If the 7535 is drawing power
from its battery, this option is ignored and the other parameters defined in Display
Properties dialogue box take affect.
5.5.1.3
•
Display Appearance
In the Display Properties dialogue box, open the Appearance tab.
Figure 5.5 Display Appearance Properties
This dialogue box allows you to customize the display colour scheme.
Psion Teklogix 7535 Hand-Held Computer User Manual
91
Chapter 5: Configuration
Keyboard Properties
5.5.2 Keyboard Properties
This icon displays the Keyboard Properties dialogue box in which you can adjust the
repeat rate of the keys, the intensity of the keyboard backlight and the behaviour of
the  and  modifier keys. This dialogue box also allows you to
define macro keys and Unicode characters.
•
In the Control Panel, choose the Keyboard icon.
Figure 5.6 Choosing The Keyboard Icon
5.5.2.1
•
Key Repeat
In the Keyboard Properties dialogue box, open the Repeat tab.
Figure 5.7 Key Repeat Properties
92
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Keyboard Backlight
Repeat Delay
The value assigned for this parameter determines the delay in milliseconds between
repeat characters. Sliding the Repeat Delay bar to the left increases the delay between
key repeats while sliding the bar to the right shortens the repeat delay time.
Repeat Rate
The value assigned for the Repeat Rate parameter determines how quickly the key you
press repeats and is measured in characters per second (cps). Sliding the bar to the
left slows the repeat rate, and sliding the bar to the right increases the repeat rate.
Note: Use the field at the bottom of this dialogue box to test the repeat delay and
rate settings you’ve chosen.
5.5.2.2
•
Keyboard Backlight
In the Keyboard Properties dialogue box, open the Backlight tab.
Figure 5.8 Keyboard Backlight Properties
ON Threshold
The ON Threshold sliding bar allows you to determine how dark the ambient light needs
to be before the keyboard backlight turns on.
Intensity
This parameter is used to adjust the light intensity of the 7535 keyboard backlight.
Sliding the bar to the left darkens the keyboard backlight intensity, and sliding it to
the right lightens the intensity.
Psion Teklogix 7535 Hand-Held Computer User Manual
93
Chapter 5: Configuration
Keyboard One Shot Modes
ON Time
The value chosen from this dropdown menu determines the duration of time that the
keyboard backlight stays on when a unit is not in use.
5.5.2.3
•
Keyboard One Shot Modes
In the Keyboard Properties dialogue box, open the One Shots tab.
Figure 5.9 Keyboard One Shot Properties
When these options are enabled (√), the  and  keys only
remain active until the next key is pressed. If the ‘One Shots’ options are disabled
(the checkbox is left blank), the  and  keys are locked ‘on’
when pressed only once; they remain ‘on’ until they are pressed a second time to
unlock them.
Note: Keep in mind that checking the taskbar lets you know whether or not
these keys are locked on. When the  and  keys
are locked ‘on’, the taskbar at the bottom of the screen displays them
in uppercase characters – BLUE KEY and ORANGE KEY. If these keys are displayed in lowercase characters in the taskbar, you’ll know that the Blue Key
and the Orange Key are not locked. They will become inactive following a
key press.
94
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Keyboard Macro Keys
5.5.2.4
•
Keyboard Macro Keys
In the Keyboard Properties dialogue box, open the Macros tab.
Figure 5.10 Macro Dialogue Box
A macro has 20 programmable characters (or “positions”). The macro keys can be
programmed to replace frequently used keystrokes, along with the function of
executable keys including ,  and  (-),
function keys and arrow keys.
Recording And Saving A Macro
You can program up to 12 macro keys on a 58-key keyboard and 6 macro keys on a
36-key keyboard.
•
In the Macro: menu, highlight a macro key number – for example, macro 1 to
assign a macro to macro key . Press the  key twice to highlight
the Record Macro button, and press .
Psion Teklogix 7535 Hand-Held Computer User Manual
95
Chapter 5: Configuration
Keyboard Macro Keys
A message screen is displayed instructing you to ‘Please Enter Key Strokes’.
Figure 5.11 Recording A Macro
•
•
Type the macro sequence you want to assign to the Macro key. You can type
text and numbers, and you can program the function of special keys into a
macro.
When you’ve finished recording your macro sequence, press the key
sequence –   .
A new screen displays the macro sequence you created. The Save Macro button is
highlighted.
•
Press  to save your macro.
Note: If you want to discard the macro you’ve just created, press the  key
to highlight the Discard Macro button and press .
Executing A Macro
To execute a macro:
•
96
Press the macro key to which you’ve assigned the macro. For example, if
you created a macro for macro key ‘1’, press  to execute the macro.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Unicode Mapping
Deleting A Macro
To delete a macro:
•
•
5.5.2.5
•
In the Macros tab, use the arrow keys to highlight the macro number you want
to delete.
Press  to highlight the Delete Macro button, and press .
Unicode Mapping
In the Keyboard Properties dialogue box, open the Unicode Mapping tab.
Figure 5.12 Unicode Mapping
The Unicode Mapping tab is used to map combinations of virtual key values and
 and  states to Unicode™ values. This tab shows the configured
Unicode character along with the Unicode value. For example, the sample screen
above shows “a (U+0061)” indicating that the character “a” is represented by the
Unicode value “0061”, and so on. Keep in mind that Unicode configurations are
represented as hexidecimal rather than decimal values.
All user-defined Unicode mappings are listed in the Unicode Mapping tab in order of
virtual key value, and then by order of the shift state. If a Unicode mapping is not
listed, the Unicode mapping is mapped to the default Unicode value.
Psion Teklogix 7535 Hand-Held Computer User Manual
97
Chapter 5: Configuration
Unicode Mapping
Adding And Changing Unicode Values
Important:
•
Changes to Unicode mappings are not saved until you exit the
Keyboard Properties dialogue box.
Press  to highlight the Add/Change button, and press .
Figure 5.13 Adding And Change Unicode Values
•
•
Highlight the a value in the Unicode mapping list – in the sample screen
above, a value will be assigned to virtual key 0 (VK 0).
Press  to position the cursor in the ‘Unicode Mapping’ field and
type a Unicode value for the highlighted key.
Note: To add a shifted state –  and/or , press  to position the cursor in the checkbox next to ‘SHIFT Pressed’ and/or ‘CTRL
Pressed’. Press  to select (√) the shift state you want to assign.
Removing Unicode Values
•
•
98
In the ‘Unicode Mapping’ tab, highlight the item you want to delete, and
press  to highlight the Remove button.
Press  to delete the value.
Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Volume And Sound Properties
5.5.3 Volume And Sound Properties
Note: Sounds (wave files) cannot be reproduced on 7535 units. The conditions
under which 7535s emit sounds are tailored from within the application
installed on your unit.
• In the Control Panel, choose the Volume & Sounds icon.
Figure 5.14 Choosing The Volume Icon
5.5.3.1
Volume Adjustments
Figure 5.15 Volume Settings
•
•
Slide the volume button to the left to lower the beeper volume or to the right
to increase the beeper volume.
Under the heading ‘Enable sounds for:’, enable (√) the conditions under which
you want the 7535 to emit a beep.
Psion Teklogix 7535 Hand-Held Computer User Manual
99
Chapter 5: Configuration
Power Management Properties
5.5.4 Power Management Properties
This icon displays a Power Properties dialogue box that indicates the unit’s battery
capacity and allows you to manage battery use.
•
In the Control Panel, choose the Power icon.
Figure 5.16 Choosing The Power Icon
5.5.4.1
•
Battery Capacity
In the Power Properties dialogue box, open the Battery tab.
Figure 5.17 Power Battery Properties
The Battery tab details information about the battery installed in your 7535.
100 Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Power Saving Schemes
5.5.4.2
•
Power Saving Schemes
In the Power Properties dialogue box, open the Schemes tab.
Figure 5.18 Power Scheme Properties
Power Scheme
This dropdown menu allows you to specify whether the unit is using AC Power or
Battery Power.
Switch State To Suspend
Important:
Psion Teklogix recommends setting the Suspend value to 10 minutes. Setting ‘Switch State To Suspend’ to ‘Never’ will adversely
affect the battery run time.
To further reduce power consumption, carefully consider the
duration of time that the display backlight is ‘on’ (see “Display
Backlight” on page 89).
When the 7535 is idle – not receiving any user input (a key touch, a scan, and so on)
or system activity (serial data, an activity initiated by an application, and so on), the
hand-held uses the value assigned in the Switch State To Suspend field to determine when
the unit will go to sleep (appear to be off).
When the time in the Suspend field elapses without any activity, the unit enters Suspend
state. In Suspend state, the 7535 CPU enters a sleep state, and the radio is shut off. The
state of the device (RAM contents) is preserved. Pressing  wakes the
system from suspend state. When the 7535 is in suspend state, the network
connection will not be broken immediately. If the connection is dropped, you must
re-establish the network connection.
Psion Teklogix 7535 Hand-Held Computer User Manual
101
Chapter 5: Configuration
Suspend Threshold
5.5.4.3
•
Suspend Threshold
In the Power Properties dialogue box, open the Suspend Threshold tab.
Figure 5.19 Suspend Threshold Properties
Suspend Threshold
The sliding bar in this tab is used to set the battery capacity (as a percentage value)
at which the hand-held will be forced into a suspend state. For example, if you slide
the bar in the Suspend Threshold tab to the right to the 10% level, when the battery
capacity falls to 10%, the 7535 will enter suspend state. You will not be able to
resume until the battery is charged, or you operate the 7535 using AC power. The
allowable threshold ranges from 0 to 50%. The default value is 0%.
Note: The7535 hand-held does not enter suspend state when it is using
AC power.
Main Battery Status
This field indicates the status of the main battery.
Estimated Operating Time
This field estimates the length of time the 7535 can remain ‘on’ (operating) before
reaching the configured Suspend Threshold.
Estimated Battery Backup Time
This field displays the amount of time the state of the 7535 will be maintained in
suspend at the currently configured Suspend Threshold.
102 Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Charger Details
5.5.4.4
•
Charger Details
In the Power Properties dialogue box, open the Charger tab.
When the 7535 is in a Combo Dock, enabling (√) Allow Battery Calibration in this tab
allows a battery requiring recalibration to be fully discharged and recharged.
Recalibration occasionally extends the battery charge time. If you prefer that the
battery always be charged in the shortest time possible, do not check this box.
5.5.5 Stylus Properties
Note: Touchscreen calibration may not be enabled on your unit. If your screen
appears to require recalibration, contact your supervisor.
•
In the Control Panel, choose the Stylus icon.
Figure 5.20 Stylus Icon
Psion Teklogix 7535 Hand-Held Computer User Manual
103
Chapter 5: Configuration
Setting Double-Tap Sensitivity
5.5.5.1
•
Setting Double-Tap Sensitivity
In the Double-Tap tab, follow the directions to tailor the sensitivity of the stylus
when you tap on the touchscreen.
Figure 5.21 Setting Stylus Sensitivity
5.5.5.2
Touchscreen Calibration
Touchscreens rarely require recalibration. However, if your touchscreen has never
been calibrated or if you find that the stylus pointer is not accurate when you tap on
an item, follow the directions below.
•
Choose the Calibration tab and then tap on the Recalibrate button.
Figure 5.22 Calibrating The Touchscreen
•
Follow the directions in the Calibration tab to recalibrate the screen.
104 Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Certificate Assignment
5.5.6 Certificate Assignment
•
In the Control Panel, choose the Certificate icon.
The dialogue box is used in conjunction with 802.1x authentication to enhance 7535
security.
Figure 5.23 Certificates Dialogue Box
For a detailed description about Certificate setup for both the server and client-side
devices (7535s), refer to the following website:
www.microsoft.com/windows2000/techinfo/planning/walkthroughs/default.asp - "Security Services"
Note: When importing certificates, the 7535 only recognizes .cer files.
Psion Teklogix 7535 Hand-Held Computer User Manual
105
5.7 Scanner Properties Setup
The Teklogix Scanners icon in the Control Panel provides dialogue boxes in which you can
tailor bar code options and choose the bar codes your scanner will recognize.
5.7.1 Scanner Options
Figure 5.45 Bar Code Options
To display the sub-menus available in the Options tab:
•
Highlight the option you want to work with, and press the right
 key.
To change a parameter:
•
Highlight the parameter and press the  arrow key, or press the
 key.
If a field requires text entry, a text field is displayed in which you can type
the appropriate value.
Display Parameters
Scan Result
When this parameter is enabled (set to ‘ON’), the type of bar code and the result of
the scan appear on the screen. Note that this information is only displayed after a
successful decode and is visible only while the scanner trigger is pressed. When the
trigger is released, this information is cleared from the screen.
Chapter 5: Configuration
Scanner Options
Scan Indicator
When this parameter is enabled (set to ‘ON’), the laser warning logo appears on the
display whenever the scanner is activated.
Scan Result Time (sec)
The value assigned to the “Scan Result Time (sec)” parameter determines how long
the scan results of a successful scan are displayed on the screen. Time is measured in
seconds, and a value of “0” (zero) disables the parameter.
Note: To remove the scan result from the screen before the “Result Time” has
expired, point the scanner away from the bar code and press the trigger.
Scan Beep
This parameter determines whether or not the 7535 emits an audible scanner ‘beep’
when a scan is performed. Set this parameter to either ‘ON’ to enable the beeper or
‘OFF’ to disable it.
Scan Log File
If this parameter is enabled, the input barcode and the modified/translated output bar
code are logged in the file \Flash Disk\ScanLog.txt. Keep in mind that if the ‘Scan
Log File’ is enabled, there is a slight performance effect when performing multiple
scans since the log file is written to persistent storage.
Double Click Parameters
Click Time (msec)
This parameter controls the maximum gap time (in milliseconds) for a double-click.
If the time between the first and second clicks of the scanner trigger is within this
time, it is considered a double-click. The allowable range is 0 to 1000. A value of
zero disables this feature.
A double-click produces different results depending on whether or not a value is
assigned in the “Click Data” parameter. When a value is not assigned for the “Click
Data”, double-clicking the scanner trigger overrides the target dot delay set in the
“Dot Time” parameter and initiates a normal scan sweep. If a value is assigned for
the “Click Data” parameter, double-clicking the scanner trigger inserts the “Click
Data” value rather than initiating a scan.
Psion Teklogix 7535 Hand-Held Computer User Manual
119
Chapter 5: Configuration
Scanner Options
Click Data
For both integrated and external scanners, this parameter determines which
character is sent to the application installed in your 7535 following a double-click.
A dialogue box appears, asking that you press the key you want to insert. The
ASCII/Unicode key value of the keypress is displayed.
Pressing the  key in this dialogue box resets the data to zero.
Options
Dot Time (msec)
The value selected for “Dot Time (msec)” determines (in milliseconds) how long the
targeting dot remains on before the scanner switches to a normal scan sweep. The
allowable values are: 0, 0.1, 0.5, 1.0, 1.5, 2.0, 2.5 and 3.0
seconds. A value of 0 (zero) disables the target dot.
Short Code
When enabled (set to ‘ON’), this parameter allows scanning of short I 2 of 5 bar
codes (2 characters). When disabled, these short bar codes are rejected.
Enabling “Short Code” may reduce the robustness of the decoding since the
7535 must decode more potential bar codes; it is therefore not recommended for
general-purpose bar codes with 4 or more characters.
Verify
The value entered for this parameter determines the number of correct additional
decodes required after the initial decode before a bar code is accepted. Higher
values significantly increase the time it takes to decode a bar code but also improve
the reliability of the decoded bar code.
Security
This parameter controls the tolerance for decoding edge-to-edge bar codes
(Code 93, Code 128, UPC/EAN). Lower values have a lower tolerance for misreads,
but they also increase the time it takes to decode the bar code. The default value of
30 is generally a good compromise setting.
120 Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Bar Codes
5.7.2 Bar Codes
Figure 5.46 Bar Code Selection
All the available bar code symbologies can be selected from this menu.
Important:
To improve the decode speed and performance, enable (set to
‘ON’) only those codes that are required by the application.
Keep in mind that some bar code types are only available when an internal imaging
scanner is installed. The bar code settings do not affect the operation of internal or
external decoded scanners. These scanners must be configured by scanning special
configuration bar codes. These configuration bar codes affect the communication
speed or data format between the scanner and the 7535 and must not be changed.
The scanner manufacturer provides programming manuals for configuration
purposes.
• For Symbol, refer to “Programming Guide P300”.
• For PSC, refer to “Powerscan Programing guide (PSC)”.
Psion Teklogix 7535 Hand-Held Computer User Manual
121
Chapter 5: Configuration
Code 39 Settings
Figure 5.47 Code 39 Bar Code Settings
A ‘plus’ sign (+) to the left of the each bar code listed in this Barcodes tab indicate that
that a sub-menu of parameters is attached. To work with a sub-menu:
•
•
•
Highlight the bar code you want to work with, and press the 
arrow key to display the sub-menu.
Use the  and  arrow keys to highlight a parameter.
To change a parameter value, press  or the  arrow key.
If a field requires text entry, a text box is displayed in which you can enter
the appropriate value.
5.7.2.1
Code 39 Settings
Full Ascii
If this parameter is enabled (set to ‘ON’), the characters +, %, and / are used as
escape characters. The combination of an escape character and the next character
is converted to an equivalent ASCII character.
Include Check
If this parameter is enabled (set to ‘ON’), the check digit is included with the
decoded bar code data.
122 Psion Teklogix 7535 Hand-Held Computer User Manual
Chapter 5: Configuration
Code 39 Settings
AIAG Strip
If this parameter is enabled (set to ‘ON’), the AIAG data identifier is removed from
each decoded Code 39 label. The data identifier occurs in the first position next to
the Code 39 start character. It can be a single alphabetic character or a series of
numeric digits followed by an alphabetic character. This identifier defines the
general category or specific use of the data contained in the rest of the bar code.
Note: If your unit is operating with the Psion Teklogix TESS application, this
parameter should not be used in conjunction with the TESS AIAG feature.
This is because the 7535 hand-held performs the strip function before it
processes the data through the AIAG feature; if the prefix is stripped, the
data is not identified as AIAG.
Error Accept
If the “Err Accept” and “AIAG Strip” parameters are enabled (set to ‘ON’), all label
data without an AIAG identifier character is accepted. If the “Err Accept” parameter
is disabled and the “AIAG Strip” parameter is enabled (set to ‘ON’), the label data is
not accepted.
Mod Checks
Mod 43 Check
If this parameter is enabled (set to ‘ON’), the Mod 43 check digit is calculated.
Mod 10 Check
If this parameter is enabled (set to ‘ON’), the Mod 10 check digit is calculated.
None
If you choose ‘None’, a check is not executed.
Field Size/Chars
Field Size
The field size is the length of the field after the first character is stripped and
the prefix and suffix characters are added. If the field size is non-zero, only
bar codes of that length are passed through.
Psion Teklogix 7535 Hand-Held Computer User Manual
123
Chapter 5: Configuration
Code 128 Settings
Prefix Char
This character, if non-zero, is added before a successfully decoded bar code. Press
the key you want to insert in the dialogue box attached to this parameter. The
ASCII/Unicode key value of the keypress is displayed.
Pressing the  key in this dialogue box resets the data to zero.
Suffix Char
Note: The appended character is treated as any other keyboard character.
For example, if  is pressed, the usual action for that key is
performed. If your unit is operating with the Psion Teklogix ANSI
emulation application, the 7535 transmits the escape sequence
associated with the function immediately after the bar code data.
This character, if non-zero, is added after a successfully decoded bar code. Press the
key you want to insert in the dialogue box attached to this parameter. The
ASCII/Unicode key value of the keypress is displayed.
Pressing the  key in this dialogue box resets the data to zero.
Strip Leading
This parameter determines the number of characters that will be removed from the
beginning of the bar code before the prefix character is added.
Note: For Code 39 bar codes, the “AIAG Strip” is performed before the
“Strip Leading”.
Strip Trailing
The value entered in this parameter determines the number of characters that will be
removed from the end of the bar code before the suffix character is added.
5.7.2.2
Code 128 Settings
Include Sym
Setting “Include Sym” to ‘ON’ causes the group separator(s) and start code
contained in this type of bar code to be displayed on the screen.
Note: This option is available only when ‘EAN/UCC 128’ is selected.
124 Psion Teklogix 7535 Hand-Held Computer User Manual

Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : No
Page Count                      : 135
Has XFA                         : No
XMP Toolkit                     : XMP toolkit 2.9.1-13, framework 1.6
About                           : uuid:fb36db67-6bf0-464a-983d-6ebc7176aef7
Modify Date                     : 2004:05:10 10:47:56-04:00
Create Date                     : 2004:05:10 10:47:24-04:00
Metadata Date                   : 2004:05:10 10:47:56-04:00
Document ID                     : uuid:5adb1138-a4b9-487d-8dd0-e79147652a93
Format                          : application/pdf
Title                           : 8000007 Book
Creator                         : FrameMaker 7.0
Author                          : Eva Szabo
Producer                        : Acrobat Distiller 4.0 for Macintosh
EXIF Metadata provided by EXIF.tools
FCC ID Filing: GM37535OEM186

Navigation menu