Motors | Automation | Energy | Transmission & Distribution | Coatings

CFW11
Variable Frequency Drive

g

Easy installation of
options and 		
accessories

g

Free superdrive PC/
Drive communication
software

USACFW1109

www.weg.net

CFW11
Variable Frequency Drives
WEG's CFW11 uses state-of-the-art technology to control motors
up to 600HP. Aimed at increasing customers productivity, the
CFW11 offers the following innovations:

Standard Features

Applications
 Pumps
Fans / Blowers
g Conveyors
g Compressors
g 
Agitators and Mixers
g Extruders
g Grizzly Feeders
g Centrifuges
g Cranes and Hoists
g Rollout Tables
g Presses
g Saws
g
g

Options
Safety stop in
compliance
with EN 954 - 1 /

g

g

g

g

category III**
External control feed
with 24 Vdc
RFI filter in
compliance with EN
61800 - 3 (internal)**
DB Resistors 		
available upon
request


Same
programming as all other WEG VFD's
Plug and play philosophy (connect and use) enables quick and easy
installation of accessories and options.
g
USB for microcomputer connection for using SUPERDRIVE programming
and monitoring software as well as updating inverter firmware.
g
Human-Machine Interface (HMI) with backlit graphic display and soft-keys,
greatly facilitates inverter programming and operation.
g
DC link inductors (symetrically connected to positive and negative DC link
terminals) enable compliance with IEC61000-3-12 standard requirements
regarding harmonics, (no need for external line reactance)
g
Intelligent thermal management enables full protection of IGBTs, monitoring
of heatsink and internal air temperature.
g
Automatic control of the heatsink fan with speed sensor (additional
protection) and easily detachable from the unit for cleaning and
maintenance.
g
N ormal Duty and Heavy Duty ratings to adapt optimally to all kinds of
loads.
g
Protection with failure and alarm warnings.
g
Motor overload protection in compliance with IEC 60947-4-2/UL 508 C.
g
Memory card built into the standard product allows user to create functions
without the need to use an external PLC (soft-PLC via IEC61131-3
programming software)
g
Guided start-up simplifies initial user
programming.
g
Real time clock
g
TRACE / SCOPE function to assist with the start-up and system diagnostics.
g
g

Mounting Options
** Factory ordered

2

1-800-ASK-4WEG

Data is subject to change without notice.

www.weg.net

CFW11
Variable Frequency Drives
1.5 to 600 HP
Coding
1.
CFW11

2
0006

3
T

4
4

5
O

6
N1

7
Z

1. CFW11 series
2. Frame Size:

= A, B, C, D or E

0006 = 6 Amps
0024 = 24Amps
0242 = 242Amps
0601 = 601 Amps

3. Number of Phase:

B = Single phase or Three phase
S = Single phase
T = Three Phase

4. Input Voltage:

2 = 200...240VAC
4 = 380...480VAC

5. Options:

S = Standard
O = An option function built-in (Ex. ON1 - NEMA1 included)

6. Enclosure:

N1 = NEMA 1

7. End of Code:

Z

WEG Automation - Products and Solutions

3

www.weg.net

Variable Frequency Drives
CFW11
Plug and Play

The CFW11 frequency inverter incorporates Plug and Play technology automatically
recognizing and configuring accessories and options used, enabling easy installation and
safe operation while eliminating manual configuration.
Accessories
Name

Description

Slot

IOA-01

IOA Module for CFW11: 1 analog input (AI4 - 14
bits, voltage or current); 2 digital inputs; 2 analog
outputs (AO3 and AO4 -14 bits, voltage or
current); 2 digital outputs (open-collector). All
analog input and output are galvanic isolated.

1

IOB-01

IOB Module for CFW11: 2 isolated analog inputs
(AI3 and AI4 - 12 bits, voltage or current); 2 digital
inputs; Provides Galvanic Isolation for AO1 and
AO2 - 11 bits, voltage or current); 2 digital outputs
(open-collector). All analog inputs and outputs are
galvanically isolated.

1

IOC-01 (*)

8 digital inputs and outputs

1

IOE-01 (*)

6 - PT100 or KTY 84 - thermistor inputs

1

ENC-01

Interface for incremental encoder 5 to 12Vdc,
100kHz (1) with repeater

2

ENC-02

Interface for incremental encoder 5 to 12Vdc,
100kHz(1)

2

RS485-01

Interface for RS-485 serial communication
(modbus)

3

RS232-01

Interface for RS-232C serial communication

3

CAN/RS485-01

CAN interface (CANopen, DeviceNet); RS-485

3

CAN interface (CANopen, DeviceNet)

3

Profibus DP interface

3

CAN-01
PROFIBUS DP-01
(*)

PLC functions; IEC programming; electronic gear box
9 digital inputs; 3 relay outputs; 3 digital outputs
PLC11-01 (*)

14-bit analog input; 2 analog outputs with 14-bit
resolution

1, 2
and 3

2 encoder interfaces; RS-485 MODBUS-RTU; CAN
(CANopen, DeviceNet, CANopen master/slave)
PROFIBUS DP-05*

Profibus DP interface (Anybus)

4

Devicenet-05*

Devicenet 4 interface (Anybus)

4

EtherNet IP-05 (*)

Ethernet IP interface (Anybus)

4

HMID - 01

Blind cover for slot HMI

-

RHMIF - 01

Frame for remote HMI

-

KN1A - 01

Conduit kit for size A

-

KN1B - 01

Conduit kit for size B

-

KN1C - 01

Conduit kit for size C

-

Note: * Anybus card goes in slot 4 and allows the user to combine PLC11 board with Profibus DP-05,
Devicenet-05 or Ethernet IP-05

4

1-800-ASK-4WEG

www.weg.net

Variable Frequency Drives
CFW11
Superdrive Programming Software

Programming software for PC (USB connection), Windows™
environment for parametrization, command and monitoring
of CFW11 inverters.
Human/Machine Interface

Left soft key: function
defined by the text in the display

Right soft key: function defined by
the text in the display.

Monitoring Modes

WEG Automation - Products and Solutions

5

www.weg.net

Variable Frequency Drives
CFW11
(NEMA1/IP21 Frame size A, B, C – NEMA1/IP20 Frame Size D)

480V

230V

Motor
Volts

HP

Amps

HP

Amps

CATALOG NUMBER

INPUT POWER SUPPLY: SINGLE OR THREE PHASE - 200…240V
1.5
6
1.5
5
CFW110006B2ON1Z
2
7
2
7
CFW110007B2ON1Z
INPUT POWER SUPPLY: SINGLE PHASE - 200…240V
3
10
3
10
CFW110010S2ON1Z
INPUT POWER SUPPLY: THREE PHASE - 200…240V
2
7
1.5
5.5
CFW110007T2ON1Z
3
10
2
8
CFW110010T2ON1Z
5
13
3
11
CFW110013T2ON1Z
5
16
5
13
CFW110016T2ON1Z
7.5
24
7.5
20
CFW110024T2ON1Z
10
28
10
24
CFW110028T2ON1Z
10
33.5
10
28
CFW110033T2ON1Z
15
45
15
36
CFW110045T2ON1Z
20
54
20
45
CFW110054T2ON1Z
25
70
20
56
CFW110070T2ON1Z
30
86
25
70
CFW110086T2ON1Z
40
105
30
86
CFW110105T2ON1Z
50
142
40
115
CFW110142T2ON1Z
60
180
50
142
CFW110180T2ON1Z
75
211
60
180
CFW110211T2ON1Z
50
142
40
115
CFW110142T2ON1DBZ
60
180
50
142
CFW110180T2ON1DBZ
75
211
60
180
CFW110211T2ON1DBZ
INPUT POWER SUPPLY: THREE PHASE - 380…480V
2
3.6
2
3.6
CFW110003T4ON1Z
3
5
3
5
CFW110005T4ON1Z
5
7
3
5.5
CFW110007T4ON1Z
7.5
10
5
10
CFW110010T4ON1Z
10
13.5
7.5
11
CFW110013T4ON1Z
10
17
10
13.5
CFW110017T4ON1Z
15
24
10
19
CFW110024T4ON1Z
20
31
15
25
CFW110031T4ON1Z
25
38
20
33
CFW110038T4ON1Z
30
45
25
38
CFW110045T4ON1Z
40
58.5
30
47
CFW110058T4ON1Z
50/60
70.5
40
61
CFW110070T4ON1Z
75
88
50
73
CFW110088T4ON1Z
75
105
75
88
CFW110105T4ON1Z
100/125
142
75
115
CFW110142T4ON1Z
150
180
100 142
CFW110180T4ON1Z
175
211
125 180
CFW110211T4ON1Z
75
105
75
88
CFW110105T4ON1DBZ
100/125
142
75
115
CFW110142T4ON1DBZ
150
180
100 142
CFW110180T4ON1DBZ
175
211
125 180
CFW110211T4ON1DBZ
200
242
150 211
CFW110242T4SZ
250
312
200 242
CFW110312T4SZ
300
370
250 312
CFW110370T4SZ
350
477
300 370
CFW110477T4SZ
400
515
350 477
CFW110515T4SZ
500
601
450 515
CFW110601T4SZ
600
720
500 601
CFW110720T4SZ

Notes: ”HP” rating based on FLA values from WEG W22, 2 and 4 poles, 460VAC, NEMA Premium motors”.
Use as a guide only. Motor FLA may vary with speed and manufacturer.
ALWAYS compare motor FLA to Nominal AMPS of VFD and overload conditions.

6

1-800-ASK-4WEG

Frame
Enclosure
Size

DB

DIMENSIONS
HxWxD

App. Shpg. Wt.
(lbs.)

Multiplier
Symbol

A
A

NEMA 1
NEMA 1

YES

12.04 x 5.71 x 8.94
12.04 x 5.71 x 8.94

19.9
20.8

V1
V1

A

NEMA 1

YES

12.04 x 5.71 x 8.94

20.8

V1

A
A
A
A
B
B
B
C
C
C
D
D
E
E
E
E
E
E

NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1

YES

12.04 x 5.71 x 8.94
12.04 x 5.71 x 8.94
12.04 x 5.71 x 8.94
12.04 x 5.71 x 8.94
13.82 x 7.45 x 8.94
13.82 x 7.45 x 8.94
13.82 x 7.45 x 8.94
17.64 x 8.66 x 11.51
17.64 x 8.66 x 11.51
17.64 x 8.66 x 11.51
19.82 x 11.81 x 12
19.82 x 11.81 x 12
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1

19.9
19.9
20.8
21.2
28.5
28.5
28.5
44.1
45
49.2
115.9
120.2
150
150
150
150
150
150

V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1

A
A
A
A
A
B
B
B
C
C
C
D
D
E
E
E
E
E
E
E
E
F
F
F
F
G
G
G

NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
NEMA 1
IP20
IP20
IP20
IP20
IP20
IP20
IP20

12.04 x 5.71 x 8.94
12.04 x 5.71 x 8.94
12.04 x 5.71 x 8.94
12.04 x 5.71 x 8.94
12.04 x 5.71 x 8.94
13.82 x 7.45 x 8.94
13.82 x 7.45 x 8.94
13.82 x 7.45 x 8.94
17.64 x 8.66 x 11.51
17.64 x 8.66 x 11.51
17.64 x 8.66 x 11.51
19.82 x 11.81 x 12
19.82 x 11.81 x 12
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
26.6 x 13.2 x 14.1
48.6 x 16.9 x 14.2
48.6 x 16.9 x 14.2
48.6 x 16.9 x 14.2
48.6 x 16.9 x 14.2
50 x 21.1 x 16.8
50 x 21.1 x 16.8
50 x 21.1 x 16.8

19.9
20.3
20.3
20.8
21.2
28.5
29.8
31.3
45.9
52.9
54.9
119.5
122.8
150
150
150
150
150
150
150
150
267
271
277
287
420
425
441

V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1
V1

NO
YES

YES

NO

YES

NO

NO

www.weg.net

Variable Frequency Drives
CFW11
Options and Accessories

Shielding Kit

Conduit Kit

Keypad Accessories and Remote Keypad
Cables

PLC & Flash
Memory
Modules

Communication Modules

Encoder
Modules

I/O Exp
Modules

DESCRIPTION

CATALOG NUMBER

Multiplier Symbol

IOA-01

V1

IOB-01

V1

Incremental encoder module, 5 to 12 VDC at 100 kHZ, with encoder signal repeater

ENC-01

V1

Incremental encoder module, 5 to 12 VDC at 100 kHZ, without encoder signal repeater

ENC-02

V1

RS485-01
RS232-01

V1
V1

RS232-02

V1

CAN/RS485-01
CAN-01
PROFDP-05
DEVICENET-05
ETHERNET/IP-05
RS232-05
RS485-05

V1
V1
V1
V1
V1
V1
V1

PLC11-01

V1

IOA Module for CFW11: 1 analog input (AI4 - 14 bits, voltage or current); 2 digital inputs; 2 analog
outputs (AO3 and AO4 -14 bits, voltage or current); 2 digital outputs (open-collector). All analog
input and output are galvanic isolated.
IOB Module for CFW11: 2 isolated analog inputs (AI3 and AI4 - 12 bits, voltage or current); 2 digital
inputs; Provides Galvanic Isolation for AO1 and AO2 - 11 bits, voltage or current); 2 digital outputs
(open-collector). All analog inputs and outputs are galvanically isolated.

RS-485 serial communication module (Modbus-RTU)
RS-232C serial communication module (Modbus-RTU)
RS232C serial commuication module with DIP-switches for microcontroller’s flash memory
programming
CAN and RS-485 communication module (CANopen / Modbus / DeviceNet)
CAN interface module (CANopen / DeviceNet
Profibus DP interface module - Anybus card*
DeviceNet interface module - Anybus card*
Ethernet/IP interface module - Anybus card*
RS-232 serial communication module (Modbus-RTU)
RS-485 serial communication module (Modbus-RTU)
PLC functions; Ladder programming; electronic gear box; 9 digital inputs; 3 dry-contact digital
outputs; 3 open-collector digital outputs; 1 analog input (14 bits); 2 analog outputs (14 bits); 2
encoder interfaces; RS-485 Mobus-RTU interface; CAN interface (CANopen, CANopen master/slave)
Flash Memory Module for CFW11
CFW11 keypad
Frame for keypad remote assembly
Blank cover for keypad slot
1m (3.3ft) remote keypad cable
2m (6.6ft) remote keypad cable
3m (10ft) remote keypad cable
5m (16ft) remote keypad cable
7.5m (25ft) remote keypad cable
10m (33ft) remote keypad cable
Remote Station-includes Start PB, Stop PB, 1-NC and 1-NO contact block, Potentiometer 5k and
legends (22mm) replaces CFW-REM
Remote Station-includes Start PB, Stop PB, 1-NC and 1-NO contact block, Potentiometer 5k and
legends (30mm) replaces CFW-REM
Conduit Kit for frame size A
Conduit Kit for frame size B
Conduit Kit for frame size C
IP21 Kit for frame size D
Power Cables Shielding Kit for frame size A
Power Cables Shielding Kit for frame size B
Power Cables Shielding Kit for frame size C
Power cables shielding kit for frame size D
Power cables shielding kit for frame size E

MMF-01

V1

HMI-01
RHMIF-01
HMID-01
IHM-CAB-RS-1M
IHM-CAB-RS-2M
IHM-CAB-RS-3M
IHM-CAB-RS-5M
IHM-CAB-RS-7.5M
IHM-CAB-RS-10M

V1
V1
V1
V1
V1
V1
V1
V1
V1

CSW-SP3PBS

Z5

CSW30-SP3PBS

Z5

KN1A-01
KN1B-01
KN1C-01
KIP21D-01
PCSA-01
PCSB-01
PCSC-01
PCSD-01
PCSD-01

V1
V1
V1
V1
V1
V1
V1
V1
V1

*Anybus card goes in slot 4 and allows the user to combine the PLC11 board with DeviceNet, Profibus, or Enternet/IP.

Data is subject to change without notice.

WEG Automation - Products and Solutions

7

www.weg.net

Variable Frequency Drives
CFW11
Technical Data
Supply

200...240V: +10% ...-15% of rated voltage
380...480V: +10% ...-15% of rated voltage

Supply frequency

50/60Hz, +/-2Hz

Output frequency

0 to 300Hz
Vector with encoder

Types of control

Vector sensorless
V V W: voltage vector
V/F (scalar)

Ambient temperature
Humidity
Altitude

-10 ...50ºC
up to 60º with output current reduction (2%/ºC above 50ºC)
5 to 90% without condensation
0 to 1000m
Up to 4000m without current reduction (1%n for each 100m above 1000m)
Dynamic braking (available in all standard models)

Braking methods

Optimal braking
DC braking

Efficiency
Degree of protection
Possibility of flange mounting
Overload
Analog inputs

Greater than 97%
IP21 for models with A, B and C sizes
IP20 / NEMA1 for models with D size
Available in all standard models, rear part of heatsink with IP54 degree of protection
Normal Duty: 110%, 60s
Heavy Duty: 150%, 60s
1 differential, resolution 12 bits, 0 to 10V/(0)4 to 20mA
1 differential, resolution 11 bits + signal, 0 to +/- 10V/(0)4 to 20mA

Analog outputs

2 isolated, resolution 11 bits, 0 to 10V/(0)4 to 20mA

Digital inputs

6 optoisolated, bi-directional, 24Vdc

Relay outputs

3 reverse contact outputs (NO/NC), 240Vac/1A

Motor thermistor

P TC/PT100/KTY84, use 1 analog output programmed for contstant current + 1 analog input programmed
for voltage

Supply + 24Vdc available for user

24Vdc +\-20%, 500ma
IEC 60146 – Semiconductor convertors
UL508C – Safety for power conversion equipment
EN 50178 – Electronic equipment for use in power installations
EN 61800-2 – General requirements adjustable speed electrical power drive systems

Norms

EN 61800-5-1 – Safety requirements adjustable speed electrical power drive systems
E N 61800-3 – EMC product standard including specific test methods adjustable speed electrical power drive
systems
EN 60204 – Electronic equipment of machines
RoHS and WEEE Guidelines

8

1-800-ASK-4WEG

www.weg.net

Variable Frequency Drives
Communication Options & Superdrive
Profibus, Modbus and Device Net
Catalog Number

Multiplier
Symbol

SUPERDRIVE

V1

SUPERDRIVE+USB

V1

SUPERDRIVE KIT - CFW08 (KCS-CFW08 - RS232 PC Cable + CD Software)

KSD-CFW08

V1

SUPERDRIVE KIT - CFW09 (KCS-CFW09 - RS232 PC Cable + CD Software)

KSD-CFW09

V1

SUPERDRIVE G2 KIT - SSW06

KSDG2-SSW06

V1

SUPERDRIVE G2 KIT - SSW07 (KRS-232-SSW07 + CAB-RS-3 + CD Software)

KSDG2-SSW07

V1

MIW-02

V1

417102506

V1

Description
SUPERDRIVE Software
SUPERDRIVE Software + USB Cable

RS-232/485 Converter (mounted externally)
RS-485 Kit for PC

Communication Options
The table below shows the hardware options required to provide WEG VFD’s and Soft Starters
with different serial communications or networking capabilities.

CFW08

RS-232

RS-485

Profibus-DP

DeviceNet

Modbus-RTU

KCS-CFW08

KCS-CFW08 MIW-02

KCS-CFW08
MIW-02
MFW-01/PD

KCS-CFW08
MIW-02
MFW-01/DN

KCS-CFW08
MIW-02

CFW09

See CFW09 accessories

CFW11

See CFW11 accessories

SSW03

Standard

MIW-02

MIW-02
MFW-01/PD

MIW-02
MFW-01/DN

MIW-02
MFW-01/MR

SSW04

Standard

MIW-02

MIW-02
MFW-01/PD

MIW-02
MFW-01/DN

MIW-02
MFW-01/MR

SSW05

Standard

MIW-02

MIW-02
MFW-01/PD

MIW-02
MFW-01/DN

MIW-02
MFW-01/MR

SSW06

Standard

KRS-485-SSW06

KFB-PD-SSW06

KFB-DN-SSW06

MIW-02
MFW-01/MR

SSW07

See SSW07 Accessories

"RS-485 Kit for PC" is required when SUPERDRIVE communicates with a multi drive RS-485					
network. It is composed of a RS-232/RS-485 converter and a cable to connect to PC.					

Superdrive
WEG Superdrive is a windows based software program that allows serial (RS - 232 or RS - 485)
communication between a PC and all WEG Soft Starters and Variable Frequency Drives. Superdrive is
an excellent programming, documentation, and troubleshooting tool for WEG Soft Starters and VFD’s.
Superdrive is available for free download at www.wegelectric.com.
Hardware accessories may be required depending on the Soft Starter or VFD line.
Standard Features
g Online and Offline Soft Starter or VFD programming
g Command and Monitoring
g Parameter set storage in a computer file format

WEG Automation - Products and Solutions

9

www.weg.net

Notes

24/ Technical
7 Support
for Drives and Soft Starters

1-877-WEG-DRIV
(934-3748)

www.weg.net
WEG Automation - Products and Solutions

10

WEG is known for its global sales and service capabilities which
allow us to provide custom solutions all over the world. With a full
range of IEC/NEMA Global Certifications and a full-line of motors,
automation, controls, transformers, and generators, WEG can supply and support the right product for your needs anywhere in the
world. To learn more about our company and solutions, or to locate
a U.S. Distributor near you, call 1-800-ASK-4WEG.

IMPORTANT NUMBERS
for doing Business with WEG

1-800-ASK-4WEG

(275 - 4934)

1-770-338-1632		
1-800-839-2529		
1-404-431-1801		
1-877-WEG-DRIV		

Sales (M-F, 8am-5pm EST).

Fax for inside sales
Warranty & Parts
After Hours Sales Emergency
24/7 Drives Tech Support

(934 - 3748)

wegsales@weg.net
parts@weg.net		

Email
Parts Email

WEG Electric Corp.
6655 Sugarloaf Parkway, Duluth, GA 30097

WEG Electric Corp. offers the following products, and more! With a full range
of IEC/NEMA Global Certifications and a full line of products, WEG can supply
the right solution for your needs anywhere in the world. To learn more about
WEG’s products and solutions or to locate a Distributor near you, please call
1-800-ASK-4WEG or visit www.weg.net/us.
Low Voltage Motors,

Variable Frequency Drives

Custom Panels

Single and 3-Phase, 1/8 – 700HP

Low Voltage 1/4 to 2500HP, 230V – 480V

Custom configured to your specification.

General Purpose Motors

Medium Voltage 500-8000HP

NEMA 1, 12, 3R, 4 and 4X cabinets

Explosion Proof Motors

Multi-pump systems

Quick delivery of preconfigured drives

Crusher Duty Motors

NEMA 4X

and soft starters

IEC Tru-Metric Motors

Dynamic braking resistors

UL 508 certified

Pump Motors including JP/JM

Line and load reactors

Low Voltage (230-460)

P-Base Pump Motors

Plug and play technology

Made in the U.S.A.

Oil Well Pumping Motors
Pool & Spa Motors

Network communications: Profibus-DP,
DeviceNet, Modbus-RTU

Generators

Brake Motors

PLC functions integrated

Compressor Duty Motors

Complete line of options and accessories

Brushless Synchronous Generators for
diesel gen-sets up to 4,200kVA

Farm Duty Motors

Hydro-generators up to 25,000kVA

Poultry Fan Motors

Soft Starters

Auger Drive Motors

3-1500HP

IEEE 841 Motors

Oriented start-up

Power Transformers

Stainless Steel Wash Down Motors

Built-in bypass contactor

Built and engineered in North America

Saw Arbor Motors

Universal source voltage (230-575V,
50/60Hz)

Voltages < 500kV

Pad Mounted Motors

Network communications: Profibus-DP,
DeviceNet, Modbus-RTU

Station class, oil filled, round core, copper
windings

Vector Duty Motors

Complete Line of options and accessories
MV Soft-starter 3.3kV, 4.16kV: up to

Special configurations and designs
available!

3500HP, Withdrawable Power Stacks, & 8x
PT100 Temperature monitoring

Ask your WEG Sales Representative for
details.

Motors up to 70,000HP and 13,200V

Controls

Designed, built, and engineered to ANSI
standards.

Wound Rotor Systems (including starters)
up to 70,000HP and 13,200V

Mini – Contactors
IEC Contactors

Custom Solution Package Sales

Synchronous Motors up to 70,000HP and
13,200V

Thermal Overload Relays

Explosion proof motors (Ex-d) up to
1,500kW and 11kV

Molded Case Circuit Breakers

Ex-n, Ex-e, Ex-p motors

Enclosed Starters: combination & noncombination,

WEG can package any of its products for
ease of sale! Enjoy a single point of contact
for the entire package of products and
assistance from quote through after-sales
support. Ask your WEG Sales
Representative for details.

Cooling Tower Motors
Commercial HVAC Motors

Large Electric Motors
Low Voltage 3-phase motors up to
2,500HP

Manual Motor Protectors
Smart Relays

Turbo-generators up to 62,500kVA

Ratings 5-300MVA

Timing & Motor Protection Relays
Terminal Blocks

confirmed 8/2012

Please contact your authorized distributor:

WEG Electric Corp.
6655 Sugarloaf Parkway
Duluth, GA 30097
Phone: 1-800-ASK-4WEG
web: www.weg.net

USACFW1109

Pushbuttons & Pilot Lights



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : No
Create Date                     : 2011:10:06 10:01:31-04:00
Creator                         : Adobe InDesign CS5 (7.0)
Modify Date                     : 2012:08:29 09:44:20-04:00
Has XFA                         : No
XMP Toolkit                     : Adobe XMP Core 4.2.1-c043 52.372728, 2009/01/18-15:56:37
Metadata Date                   : 2012:08:29 09:44:20-04:00
Creator Tool                    : Adobe InDesign CS5 (7.0)
Instance ID                     : uuid:c789e4bc-7271-5c4e-863a-43906a118e9e
Document ID                     : xmp.did:38DAC0F81F206811923F904967C6FB95
Original Document ID            : xmp.did:E0690B6C0D206811923F904967C6FB95
Rendition Class                 : proof:pdf
History Action                  : created, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved, saved
History Instance ID             : xmp.iid:E0690B6C0D206811923F904967C6FB95, xmp.iid:E2690B6C0D206811923F904967C6FB95, xmp.iid:36DAC0F81F206811923F904967C6FB95, xmp.iid:37DAC0F81F206811923F904967C6FB95, xmp.iid:38DAC0F81F206811923F904967C6FB95, xmp.iid:A28C869D41206811923F904967C6FB95, xmp.iid:F97F117407206811AFFDBBC32CE50EA4, xmp.iid:FA7F117407206811AFFDBBC32CE50EA4, xmp.iid:FA7F1174072068118DBBA080488A0BC3, xmp.iid:CEF41415172068118DBBA080488A0BC3, xmp.iid:7FF0ECC74B2068118DBBA080488A0BC3, xmp.iid:9915A711ED2068118DBBA080488A0BC3, xmp.iid:FD7F117407206811AE56CD9AC064AE30, xmp.iid:5AF99EA038206811B34BE2502058CC91, xmp.iid:5DF99EA038206811B34BE2502058CC91, xmp.iid:0080117407206811A46CB3FEE8B207BA, xmp.iid:FE7F11740720681191098D316A9CADEA, xmp.iid:FF7F11740720681191098D316A9CADEA, xmp.iid:008011740720681191098D316A9CADEA, xmp.iid:E03982EB43226811A005EF1F23F4C13B, xmp.iid:F77F117407206811958DB9B79F6DA37F, xmp.iid:4B1B144E902068118083C5C9BE2A0320, xmp.iid:4C1B144E902068118083C5C9BE2A0320, xmp.iid:CC3CECC7AF21681180838167B8811DA4, xmp.iid:7A31A6EEAF21681180838167B8811DA4, xmp.iid:777DDF0CB021681180838167B8811DA4, xmp.iid:A0A69C343D2068118083F5E6FC60736C, xmp.iid:A03D67BC412068118083F5E6FC60736C, xmp.iid:3B5B69D35C2068118083F5E6FC60736C, xmp.iid:810BFEFE98206811822A9A4DFE752DEC, xmp.iid:C180B44099206811822A9A4DFE752DEC, xmp.iid:95EDAB1E9F206811822A9A4DFE752DEC, xmp.iid:22BDCA805E2068118083878C1C48EB14, xmp.iid:CA6A359B5E2068118083878C1C48EB14
History When                    : 2009:08:17 10:05:40-04:00, 2009:08:17 11:43:28-04:00, 2009:08:17 11:43:28-04:00, 2009:08:17 11:43:59-04:00, 2009:08:17 11:43:59-04:00, 2009:08:17 15:44:18-04:00, 2009:08:18 08:57:08-04:00, 2009:08:18 09:12:34-04:00, 2009:09:08 09:23:27-04:00, 2009:09:08 16:28:45-04:00, 2009:09:09 11:57:46-04:00, 2009:09:09 12:18:49-04:00, 2009:09:18 16:04:04-04:00, 2009:09:21 14:40:29-04:00, 2009:09:21 15:05:21-04:00, 2009:12:01 16:49:27-05:00, 2010:03:04 11:35:10-05:00, 2010:03:04 11:39:28-05:00, 2010:03:04 11:40:31-05:00, 2010:12:03 12:42:46-05:00, 2010:12:06 12:01:17-05:00, 2011:03:02 07:01:33-05:00, 2011:03:02 07:01:33-05:00, 2011:03:14 10:09:41-04:00, 2011:03:14 10:10:46-04:00, 2011:03:14 10:11:37-04:00, 2011:05:13 07:13:24-04:00, 2011:05:13 07:45:50-04:00, 2011:05:13 10:59:45-04:00, 2011:09:30 07:10:59-04:00, 2011:09:30 07:12:49-04:00, 2011:09:30 07:54:49-04:00, 2011:10:06 08:48:30-04:00, 2011:10:06 08:49:14-04:00
History Software Agent          : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0, Adobe InDesign 7.0
History Changed                 : /, /metadata, /metadata, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /, /;/metadata, /metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata, /;/metadata
Derived From Instance ID        : xmp.iid:37DAC0F81F206811923F904967C6FB95
Derived From Document ID        : xmp.did:E0690B6C0D206811923F904967C6FB95
Derived From Original Document ID: xmp.did:E0690B6C0D206811923F904967C6FB95
Derived From Rendition Class    : default
Doc Change Count                : 688
Format                          : application/pdf
Producer                        : Adobe PDF Library 9.9
Trapped                         : False
Page Count                      : 12
EXIF Metadata provided by EXIF.tools

Navigation menu