Operation and Maintenance Manual

Introduction
Read all instructions thoroughly. Installation of the OilTector must comply with all Federal, State and Local Codes, Regulations
and Practices. The OilTector must be installed by qualified personnel familiar with all applicable local electrical and mechanical codes. Refer to the National Electrical Code (NFPA 70). Failure to properly install and test this product can result in
personal injury or equipment malfunction.
The OilTector control system is designed and approved for the safe operation of pumping, alarming and monitoring of elevator
sump pits, transformer vaults and leachate well applications. The OilTector will activate a pump to remove water from elevator
pits in accordance with ASME A17.1. The OilTector stops the pump before oil or other harmful substances enter our water
supply. Indicator lights will illuminate on the control panel for the following: power, pump running, high alarm, high oil. The panel
has a set of auxiliary contacts that activate on power loss or high Oil/Water conditions. These contacts can be connected to the
OilTector remote panel which contains audio/visual alarming along with auxiliary contacts for connection to building automation
system or SCADA system. The recommended minimum sump size is Ø18” x 30” high.

Safety Guidelines
1.
2.
3.
4.
5.

6.
7.

8.

DO NOT USE WITH FLAMMABLE OR EXPLOSIVE FLUIDS SUCH AS GASOLINE, FUEL OIL, KEROSENE, ETC. DO NOT USE IN EXPLOSIVE ATMOSPHERES. PROBE/FLOAT SWITCH SHOULD
ONLY BE USED WITH WATER.
DO NOT HANDLE THE OILTECTOR SYSTEM WITH WET HANDS OR WHEN STANDING ON A WET
OR DAMP SURFACE OR IN WATER.
DISCONNECT ALL ELECTRICAL SERVICE BEFORE WORKING OR HANDLING THE OIL ALERT
SYSTEM.
INCOMING VOLTAGE MUST MATCH OILTECTOR SYSTEM VOLTAGE.
TO PREVENT ELECTRICAL SHOCK AND EQUIPMENT MALFUNCTION, USE ONLY WITH A PUMP
SUPPLIED WITH A GROUNDING CONDUCTOR AND GROUNDING-TYPE ATTACHMENT PLUG. BE
CERTAIN TO PLUG THE OILTECTOR PANEL INTO A PROPERLY GROUNDED, GROUNDING-TYPE
RECEPTACLE.
CONTROL PANEL AND ALARM MUST BE MOUNTED INDOORS. FOR OUTDOOR APPLICATIONS
CONSULT FACTORY.
SECURE LEVEL SENSOR ON DISCHARGE PIPE AT A LEVEL THAT GUARANTEES PARTIAL PUMP
SUBMERGANCE WHEN WATER LEVEL IS JUST BELOW THE “OFF” PROBE (THE LONGEST
PROBE). (See Figure 5 on page 3 of this manual). FAILURE TO PROPERLY MOUNT THE LEVEL
SENSOR MAY CAUSE THE PUMP TO ACTIVATE EVEN WHEN OIL IS PRESENT IN THE SUMP.
CAUTION! REMOVE ANY FLOAT SWITCH THAT IS CURRENTLY USED OR SUPPLIED WITH THE
PUMP. IF THE FLOAT CANNOT BE REMOVED, SECURE SWITCH SO THAT IT IS ALWAYS ON.

Part Numbers
OTC-115 - OilTector 115 volt Oil Sensor Control System (Control Panel, Alarm Panel, Level
Sensor). NEMA 4X enclosure.

OTC-230 - OilTector 230 volt Oil Sensor Control System (Control Panel, Alarm Panel, Level
Sensor). NEMA 4X enclosure.

Page 1 of 6
Manual 7235000G
DWG#7235000G

7000 Apple Tree Avenue, Bergen, NY 14416 Phone: (800) 543-2550-Fax: (585) 494-1839-www.libertypumps.com

Operation and Maintenance Manual

Description of Operation

On water rise, level reaches pump “start” probe to start the pump. Pump will remain on until level is below
“off” probe. The “off” probe senses air or oil and turns the pump off so the oil layer will not be pumped out of
the sump. If the liquid level reaches alarm probe and mechanical float, the system will differentiate between
water and oil and activate the remote alarm.

Installation of the Control Panel

1. It is highly recommended to mount the control panel in the same area as the sump pump to eliminate any
splicing of sensor and pump wires. See “Installation of Preset Level Sensor Holder” for more information on
splicing.
2. Determine mounting location for the control panel. Mount panel at the desired location making sure the
mounting location of the control panel is within 6 feet of electrical receptacle.
3. Plug pump cable into control panel receptacle cable. Plug power cable into receptacle only when ready for
testing. See Testing System installation.
4. If the panel is to be installed with conduit, the cables and cord seals must first be removed. Please make
note of wire locations. The incoming power 115V is connected to L1 and L2 of the contactor, pump receptacle is T1 and T2 on the contactor. Low voltage cable from the level sensing module: green - TB1 off probe,
yellow - TB2 start probe, red - TB3 alarm probe, white - TB4 float, black - TB5 float. Low voltage auxiliary
contacts are TB6 and TB7. Do not mix low voltage probe wires or auxiliary contacts in high voltage conduits.
See figure 3 and figure 6.

Control Panel

Figure 2

Figure 1
.50"

5.25"

4.02"

60500A0

Remote alarm can be mounted
2500 ft. from control panel!

8.82"

9.75"

120 V
Receptacle

Figure 3

Elevator Sump

Remote Alarm has
additional auxiliary
contacts for building
alarm system.

Warning – Do not mix high and low voltage circuits in the
same conduit, failure to do so will cause system malfunction. The Preset Level Sensor and Auxiliary
Contact wires are low voltage class 2 circuits
- Do not install sensor cables in conduits
with main power or pump cables.

60500A0

Pump “On”
Level
Pump “Off”
Level

Oil “Film”
Detection Level

Conduit

A

B

C

D

A Conduit – Low Voltage Preset Level Sensor
A C
B Conduit – High Voltage Pump Cable
B D
C Conduit – High Voltage Incoming Power Cable
D Conduit – Low Voltage Auxiliary Contact for Remote Alarm

Page 2 of 6
Manual 7235000G
DWG#7235000G

7000 Apple Tree Avenue, Bergen, NY 14416 Phone: (800) 543-2550-Fax: (585) 494-1839-www.libertypumps.com

Operation
Operation and
and Maintenance
Maintenance Manual
Manual

Installation of Preset Level Sensor Holder
1. Review figures 4, 5 and 6.
2. Attach sensor holder to discharge pipe or separate pipe (mounted to side wall) using the stainless
steel pipe clamp. Make sure sensor is clear of inlet water and at least 1” to 2” away from any conductive
material. Make sure the bottom probe (off level) is at the same height as the top of the pump or just slightly
below ensuring submergence of the pump. See figure 5.
3. Route the five conductor cable to the control panel through the liquid tight cord connector and tighten
compression nut.
4. Connect the wires from the level sensor to the terminal strip inside the control panel. See figure 6.
5. If splicing on sensor cable is required:

Figure 4

A. For any splicing longer than 100 feet, consult factory.
B. Use liquid tight junction boxes and appropriate liquid tight
connectors and/or conduit.

Preset Level
Sensor Holder

High Level
Float

C. Do not mix high and low voltage circuits in same junction box.
D. For level sensor splice, it is recommended to use 5 conductor,
18 AWG shielded cable. Only ground the shield on one end of
the cable – easiest to ground shield wire in panel to the ground lug.

High Level
Probe
Pump
Start

Figure 6
Circuit Board

Off
Probe

Figure 5
Discharge Pipe

4

5

Black

3

Red

2

Yellow

Green

1

White

Mount

6

Side Wall
Mount

7

Contacts
Off
Start Alarm Float Float Auxiliary
24VDC, 1A
Probe Probe Probe
Conect to Remote Alarm
Or BAS/SCADA System

5 Conductor Cable from
Preset Level Sensor
Page 3 of 6
Manual 7235000G
DWG#7235000G

7000 Apple Tree Avenue, Bergen, NY 14416 Phone: (800) 543-2550-Fax: (585) 494-1839-www.libertypumps.com

Operationand
andMaintenance
MaintenanceManual
Manual
Operation
Installation of the Alarm Panel
The OilTector Remote Alarm Panel is powered by 120 VAC coming from standard wall outlets and is transformed to 9VDC.
Installing a 9 Volt battery provides battery back-up.
When the OilTector Control Panel’s Auxiliary Contacts “close” the buzzer and light will turn “on” and the alarm panel’s auxiliary
contacts will be activated. Pressing the “silence switch deactivates the buzzer and auxiliary contacts. When the OilTector Control
Panel’s Auxiliary Contacts reset, the remote alarm panel will automatically reset itself.
Test product weekly. Make sure the green ”power on” light is “on”. Press the “Test” switch; the red alarm light and buzzer should
turn “on”. If the battery back up system is utilized, unplug the wall mount power supply (the green light will be off). Now press the
“Test” switch; the red alarm light and buzzer will turn “on”. If the buzzer sounds less loudly than when tested with the normal power
supply, then replace the battery.
1. To install/replace the battery for the backup power feature, remove the two side screws and install 9 VDC battery (Duracell
model MX 1604B2). After installing battery, press the test button to activate the alarm to make sure the battery works properly.
Reinstall side screws. See Figures 7.
2. Determine mounting location for the Alarm Panel. Make sure power outlet is within 6 feet of the alarm. Make sure the outlet
is on a separate circuit breaker from any other device and not on a switched receptacle to maintain power integrity. Mount the
alarm using two #8 x 1 1/4" self tapping screws (not included). Use #8 plastic anchor if mounting to sheet rock. See Figure 8.
The alarm can be mounted up to 2500 feet from the panel using 18 ga wire.
3. If Auxiliary Contacts are used, continue; otherwise go to step 4. Remove cover from base and remove 1/2" electrical knockout
from base. Use 16 - 2 AWG stranded wire - make sure there is at least 6" of wire inside of enclosure. Install a 1/2" strain relief
with jam nut. Connect wires for required application using wire nuts. Caution ! - When installing wires, route all wires away from
sharp objects & internal components. See figures 9 & 10.
4. There are two terminals on the bottom of the alarm panel. Connect a wire from the first terminal to the CONTROL PANEL
terminal #6 and connect another wire from the second terminal of the alarm panel to CONTROL PANEL terminal #7. See Figure
8
5. Plug the power supply into a 120VAC, 50/60 HZ standard wall outlet. For UL applications, remove center screw on receptacle
and place cord from wallmount transformer inside the plastic cord holder. Secure plastic cord holder to the receptacle by reinstall
ing screw to the center hole of receptacle. See Figure 8. For Canadian applications DO NOT INSTALL Plastic Cord Holder! The
green "Normal" light should come on.
6. Test the system by pressing the "Test" switch. The buzzer and the red warning light will be "on". The green "Normal" light will
be "off". While holding the “Test” switch, press the “Silence” switch. The buzzer will silence, but the alarm light will remain “on”.
Let go of the “Test” switch and the alarm light will turn “off” and the green “Normal” light will turn “On” indicating the system is now
in a normal condition.
Figure 7 - Installing/Replacing Battery
Battery Strap
Connector

OilTector

Duracell Model
MX1604B2
9 VDC Battery

Battery
Holder

Figure 9 - Installing Field Wiring for Auxiliary Contacts

2 wire cable
To BAS/SCADA
1/2" Strain
Relief

Figure 8 - Mounting
Use #8 X 1 1/4"
Mounting Hole (2)
Self Tapping Screws
Cover
Side Screw
120VAC Wallmount
Receptacle
Base
Terminal Block
Center
Screw
connects to terminal
Plastic
Cord
blocks 6 & 7 of the
Holder
CONTROL PANEL

Wire Nuts

1/2" Electrical
Knockout
Jam
Nut

Base

Figure 10
Auxiliary Contacts

Connects to BAS/SCADA system

White - Common
Red - Normally Closed
Black - Normally Open
Class 2, 24 VDC/VAC(50/60HZ)
500 milliamps MAXIMUM!

Page 4 of 6
Manual 7235000G
DWG#7235000G

7000 Apple Tree Avenue, Bergen, NY 14416 Phone: (800) 543-2550-Fax: (585) 494-1839-www.libertypumps.com

Operation and
and Maintenance
Maintenance Manual
Manual
Operation

Testing the complete system

Upon complete installation of controls, pump and piping, the complete system should be tested for quality assurance.
1. Test high oil circuit by lifting the float switch with the sump empty of water. Oil is non conductive like “air”, and
when the float is lifted only the HIGH OIL indicator will be illuminated. The auxiliary contacts in the control panel
and the remote alarm will activate.
2. Test a pump cycle by slowly filling tank with water. Stop filling tank with water when the level touches middle
probe. When the water touches the middle probe, pump should start and pump down to the bottom probe at
which time the pump will stop. Check discharge plumbing for leads and make sure discharge is going to the
correct area.
3. Test high water circuit. Unplug the pump from the control panel and slowly fill the tank until the water level just
touches the upper probe. When the water touches the upper probe, the HIGH WATER indicator will be illuminated. The auxiliary contacts in the control panel and the remote alarm will activate.
4. Test the remote alarm for power loss. Unplug the power cord on the control panel. The auxiliary contacts will
close and the remote alarm will activate.

Testing panel - Using 5 gallon pail.
If it is not possible to test the complete system outlined above, then test the panel operation using a 5 gallon pail
filled with water. The system requires a temporary ground wire run from the control panel into the liquid in the pail
for correct operation.
1. Run Temporary Ground wire (14 AWG Copper Wire) from the ground lug inside panel and into the pail of
water. Make sure at least ½” of copper wire is exposed and immersed in the water.
2. Before lowering the sensor probe into the pail, lift the float switch, the HIGH OIL indicator will be illuminated.
The auxiliary contacts in the control panel and the remote alarm will activate.
3. Lower the sensor probe into the bucket of water slowly so that the longest probe is immersed in the water.
Slowly continue to lower so the middle probe touches the water, the pump should activate. While the pump is
activated, slowly remove the sensor probe out of the water until the longest probe is no longer in the water, the
pump should turn off. Repeat a couple of times for quality assurance.
4. Lower the sensor probe into the bucket of water slowly so that the longest probe and the middle probe are
immersed in water, the pump will activate. Continue to lower sensor probe so that water touches the shortest
probe, the HIGH WATER indicator will be illuminated. The auxiliary contacts in the control panel and the remote
alarm will activate.
5. This completes testing. Remove temporary ground from panel and retighten ground lug with all the green
wires. Return to manual for “Installation of Preset Level Sensor Holder”.
Ground Lug
60500A0

Temporary 14 AWG Ground Wire
120 V
Receptacle

Page 5 of 6
Manual 7235000G
DWG#7235000G

7000 Apple Tree Avenue Bergen, NY 14416 Phone: (800) 543-2550-Fax:
: (585) 494-1839-www.libertypumps.com

Operation and
and Maintenance
Maintenance Manual
Manual
Operation

Maintenance
1. The preset level control must be kept clean and free of rust, mud, soap or any conductive material.
2. Every year clean probes keeping them free of debris, calcium or iron deposits.
3. Fuses in control panel are 5mm X 20mm 1/2amp for F1 and 5mm X 20mm 1amp for F2.
(Spare fuses are included for your convenience)
4. Every year replace 9 Volt Battery in Remote Alarm.

Trouble Shooting
Symptom

Possible Cause

Action

Pump does not run

Panel Power Cord Unplugged
Pump not plugged into panel
Defective Contactor
Loose level sensor wires
Pump failure

Plug in Outlet, Check Power
Plug pump to panel plug
Replace Contactor
Tighten connections
Replace pump

Pump turns off before
bottom probe

Poor pump ground or system ground

Check grounding system

Page 6 of 6
Manual 7235000G
DWG#7235000G

7000 Apple Tree Avenue Bergen, NY 14416 Phone: (800) 543-2550-Fax:
: (585) 494-1839-www.libertypumps.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2009:12:09 17:15:48-06:00
Creator                         : Adobe Illustrator CS4
Modify Date                     : 2009:12:09 17:15:48-06:00
XMP Toolkit                     : Adobe XMP Core 4.2.1-c041 52.342996, 2008/05/07-20:48:00
Metadata Date                   : 2009:12:09 17:15:48-06:00
Creator Tool                    : Adobe Illustrator CS4
Format                          : application/pdf
Title                           : Liberty Pump OilTector Installation Instructions Rev. 7235000G Page 1
Document ID                     : uuid:c1a2a87f-ccb4-4baa-b7f4-d2c50017b9cf
Instance ID                     : uuid:154d41eb-ff74-45c0-9c68-c5a6571370c2
Producer                        : Adobe PDF library 9.00
Page Count                      : 6
EXIF Metadata provided by EXIF.tools

Navigation menu