17539 1 Grundfos 95906639 Brochure User Manual
17537 1 Grundfos 59896879 Brochure 17537_1_Grundfos 59896879 Brochure 17537_1_Grundfos 59896879 Brochure pdf pumpproducts
17540 1 Grundfos 59896781 Brochure 17540_1_Grundfos 59896781 Brochure 17540_1_Grundfos 59896781 Brochure pdf pumpproducts
17527 1 Grundfos 52722393 Brochure 17527_1_Grundfos 52722393 Brochure 17527_1_Grundfos 52722393 Brochure pdf pumpproducts
17538 1 Grundfos 59896773 Brochure 17538_1_Grundfos 59896773 Brochure 17538_1_Grundfos 59896773 Brochure pdf pumpproducts
17526 1 Grundfos 52722370 Brochure 17526_1_Grundfos 52722370 Brochure 17526_1_Grundfos 52722370 Brochure pdf pumpproducts
User Manual: Pump 17539 1 Grundfos 95906639 Brochure
Open the PDF directly: View PDF .
Page Count: 84
Download | |
Open PDF In Browser | View PDF |
GRUNDFOS PRODUCT GUIDE UP Series Circulator pumps 60 Hz Contents Mission 3 Cross reference Quick cross reference for competitive 3-speed pumps Reference for replacing ALPHA models Reference for replacing Comfort models Reference for replacing TACO models Reference for replacing Bell & Gossett models Reference for replacing Laing models Reference for replacing Armstrong models Discontinued products 4 5 5 6 8 9 10 11 Performance ranges 3-speed 3-speed stainless steel Comfort Pump Closed systems Open systems Open systems 1/2" Open systems 3/4" 12 13 13 14 14 15 15 Product range Cast iron Bronze Stainless steel 16 17 18 Identification Type key Nameplate 19 20 Applications Heating systems Domestic hot-water systems Cooling systems Construction Materials of construction Installation Pumped liquids Ambient and liquid temperatures Maximum system pressure Minimum inlet pressure Performance ALPHA MixiMizer - mixing reset pump Variable-speed pump Comfort System UP 10 Comfort pump 21 21 21 21 22 22 23 23 23 23 23 24 25 26 27 28 Technical data Comfort Pump UP 10-16 B5/BN5 UP 15-10 B5/B7 UP 15-10 BUC5/7 2 29 30 31 UP 15-10 F/FR UP Comfort System 15-10 SU7P/TLC UP 15-18 B5/B7 UP 15-18 BUC5/BUC7 UP 15-29 SU/SF UP 15-35 SUC UPS 15-35 SUC/SFC UP 15-42 B5/B7 UP 15-42 BUC5/BUC7 UP 15 MixiMizer 15-42 BUC5/MR and BUC7/MR UP 15-42 F/FR UPS 15-42 F UP 15 Miximizer 15-42 FC/MR UP 15 Variable Speed 15-42 F/VS UP 15-55 SUC UPS 15-55 SFC/SUC ALPHA 15-55 F/FR/SF/LC UPS 15-58 FC/FRC UP 15-100 F UP 26-64 F UP 26 Variable Speed 26-64 F/VS UP 26-96 F/BF UP 26 Variable Speed 26-96F/VS UP 26-99 F/BF UPS 26-99 F/BFC UP 26-116 F/BF UP 26-120 U UPS 26-150 F/SF UP 43-44 F/BF UPS 43-44 FC/BFC UP 43-70 F UP 43-75 F/BF UPS 43-100 F/SF UP 43-110 F UPS 50-44 F UPS 50-60 F/SF UP 50-75 F 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 50 51 52 53 54 55 56 57 58 59 60 61 62 63 64 65 66 67 68 69 Accessories UP timer AquaStat Pump Zone Controls Packaged dielectric isolation valve sets Packaged fitting sets UP-ZV zone valves Replacement flange gaskets 71 72 73 74 75 76 78 Submittal data Submittal data 79 Further product documentation WebCAPS WinCAPS 81 82 Mission UP Series It is our mission — the basis of our existence — to successfully develop, produce and sell high-quality pumps and pumping systems world-wide, contributing to a better quality of life and a healthy environment Bjerringbro, Denmark Fresno, California Monterrey, Mexico Olathe, Kansas Allentown, Pennsylvania Oakville, Ontario • World's leading pump company • World's largest manufacturer of circulator pumps, covering more than 50% of the global market • World headquarters in Denmark • North American headquarters in Kansas City - Manufacturing in Fresno, California • 82 companies in 45 countries • More than 16 million motors and pumps produced annually worldwide • North American companies operating in USA, Canada and Mexico • Continuous reinvestment in growth and development enables the company to BE responsible, THINK ahead, and INNOVATE 3 Cross reference UP Series Quick cross reference for competitive 3-speed pumps Competitor cross-reference Model ALPHA 15-55 F/SF UPS 15-58 FC/FRC UPS 26-99 FC/BFC UPS 26-150 F/SF UPS 43-44 FC/BFC UPS 43-100 F/SF UPS 50-60 F/SF UPS 15-35 SFC UPS 15-35 SUC UPS 15-35 SUC/TLC UPS 15-55 SFC Speed TACO* Bell & Gossett* Armstrong* High 005F, 007F, 008F, 0010F-IFC, 00R-MSF1-IFC NRF-22, LR-20WR Astro 30, Astro 30-(3), Astro 50-3, Astro 230CI Med. 005F-(IFC), 007F-(IFC), 008F-(IFC), 0010F-IFC, 00R-IFC, 00R-MSF1-IFC NRF9F/LW, NRF-25 Sp-1 & 2 Astro 25, Astro 30-3 Low 005F-(IFC), 006F-(IFC), 00R-MSF1-IFC High 0013(B)-IFC NRF-36 Sp-2, NRF-45 Sp-2, H-41(B) E7(B), Astro 50(B)-(3) Med. 0011(B)-(IFC), 0014(B)-(IFC) Series 100, PL-30, PR, NRF-36, Sp-1, NRF-45 Sp-1 Astro 50(B), H41 Low — LR-15BWR Astro 30(B) High 1400-45(B), 1400-50(B) PL-55(B) E15(B) Med. 0011(B, SF), 0013(B, SF), 1400-20(B), PL-36(B) 1400-30(B), 1400-40(B) E8(B), E9(B), E11(B), E13(B) Low — NRF(NBF)-36 Sp-2 & 3 E7(B), E10(B) High 0012(B, SF)-(IFC), 113(B) HV, H-32(B) E16(B) Med. 0010(B, SF)-(IFC), 111(B) NRF-33 H32 Low 0010-MSF1-IFC, 110(B) — — High — H-51(B), H-52(B) E17(B) Med. 1400-20(B), 1400-30(B), 1400-40(B), 1400-45(B) PL-45(B), PL-50(B), NRF(NBF)-45 Sp-2 & 3, NRF-36 Sp-2 & 3 E11(B), E15(B),E16(B) Low — — 10(B), E13(B) High 1400-65 (B), 131(B) PL-130(B), E19(B), E29(B), S-35(B) E19(B), E28(B), E29(B), E30(B) Med. 1400-60(B), 121(B), 122(B), 131(B) PL-50(B), PL-75(B) — Low 120(B) – E16(B) High 005BF2-(IFC), 007(B, SF)-(IFC) NBF(SSF)-12F/LW SM-909-BF14, Astro 25B, Astro 30(B) Sp-2 Med. — — Astro 20(B), Astro 30(B)-3 Sp-1 & 2 Low — — – High — NBF(SSF)-12U/LW Astro 25BU, Astro 220, 225SSU Med. 006BC4-1, 006B7-IFC NBF-9U/LW Astro 25BU, Astro 20, 25(BU) Low 003-B4-2-IFC — — High — — Astro 20, 25BU(LC, T), Astro 25U-T Med. — — Astro 25U-T Low — — — High — — Med. 005-(B, SF), 006-BF, 007-(B, SF)(IFC), 008-(B, SF)-(IFC), 00R-SF-IFC LR-15B, NBF(SSF)-22, NBF-25 Low — — Astro 20 * Grundfos provides no guarantee as to the accuracy of competitor information listed herein. 4 Astro 30B-(3), Astro 230SS, Astro 30(B), SM-909-BF14, SM-909-BF18 Astro 30(B) Sp-2, Astro 30(B)-3 Sp-1 Astro 30(B) Sp-1, Astro 50(B) Sp-1 Cross reference UP Series Reference for replacing ALPHA models Competitor cross-reference Model ALPHA 15-55 F/SF Speed TACO* Bell & Gossett* Armstrong* High 005F, 007F, 008F, 0010F-IFC,00R-MSF1-IFC NRF-22, LR-20WR Astro 30, Astro 50-3 Med. 005F-(IFC), 007F-(IFC), 008F-(IFC), 0010F-IFC, 00R-IFC, 00R-MSF1-IFC NRF9F/LW, NRF-25 Sp-1 & 2 Astro 25, Astro 30-3 Low 005F-(IFC), 006F-(IFC), 00R-MSF1-IFC Astro 20 * Grundfos provides no guarantee as to the accuracy of competitor information listed herein. Reference for replacing Comfort models Competitor cross-reference Comparable Grundfos replacement options (UP Comfort) TACO pumps* Laing pumps* Pump type Connections Pump type Pump type 1/2" sweat/cord 003-BC4-4PNP SM-303-BS, 003-BC4-PNP, 003-BT4-PNP SMT-303-BS, SMT-303-BSW UP 10-16 B5/LC Page 29 UP 10-16 B5/TLC 29 1/2" sweat/cord/timer UP 10-16 B5/ATLC 29 1/2" sweat/stat/cord/timer SM-303-BSR, SM-303-BSW, SM303-BSRW, SMT-303-BSR, SMT-303-BSRW UP 10-16 BN5/LC 29 1/2" FNPT thread/cord SM-303-BT, SM-303-BTW, UP 10-16 BN5/TLC 29 1/2" FNPT thread/cord/timer SMT-303-BT, SMT-303-BTW, UP 10-16 BN5/ATLC 29 1/2" FNPT thread/stat/cord/timer 003-BT4-PNP (Plus Star) SM-303-BTR, SM-303-BTRW, SMT-303-BTR, SMT-303-BTRW * Grundfos provides no guarantee as to the accuracy of competitor information listed herein. 5 Cross reference UP Series Reference for replacing TACO models Competitor cross-reference Open systems: Stainless steel and bronze body pumps Comparable Grundfos replacement options Primary model (s) Page no. Conn. type Taco pumps* Pump length [inches] UP 15-10 B5 UP 15-10 B5/LC 30 UP 15-10 B5/TLC 1/2" sweat 31 UP 15-10 BUC5/TLC UP 15-10 B7 UP 15-10 B7/LC 003-BC4-PNP 1/2" sweat 4 1/4 003-BC4-1IFC Union 5 15/16 003-BC4-7PNP 1/2" sweat 4 1/4 003-BC4-3PNP 1/2" sweat 4 1/4 3/4" sweat 4 13/32 1/2" sweat 4 1/4 3/4" sweat 4 13/32 Flange 6 3/8 Union 5 15/32 3/4" sweat 6 3/8 003-BC-1 Union 6 005-BF2 Flng-R 007-BF5 Flng-R 005-SF2, 005-SFC-IFC, 007-BF5, 007-BF-IFC, 007-SF5, 007-SF5-IFC, 008-BF-IFC, 008-SF6, 008-SF-IFC Flange 008-BF6 Flng-R Flange 6 1/2 003-BC4-IFC 31 003-BC4-6PNP 003-BC4-2PNP UP 15-18 B5 006-BC4, 006-ST4 34 006-BC4-2PNP 1/2" sweat 5 UP 15-18 B5/LC 006-BC4-PNP 35 006-BC7-1IFC UP 15-18 B7 006-B4 34 006-B4-1PNP 3/4" sweat 6 3/8 UP 15-18 B7/TLC UP 15-18 BUC7 4 1/4 6 3/8 UP 15-10 BUC7/TLC UP 15-18 B7/LC 4 13/32 1/2" sweat 003-B4-PNP 3/4" sweat UP 15-18 BUC5 1/2" sweat 003-BC4-4PNP 003-B4-1PNP UP 15-10 BUC7 UP 15-18 B5/LC 003-BC4 003-B4, 003-ST4 30 UP 15-10 B7/TLC UP 15-10 BUC7/LC Pump length [inches] 5 UP 15-10 BUC5 UP 15-10 BUC5/LC Conn. type Model 006-B4-PNP 35 UP 15-29 SF 006-BC7-IFC Flange 6 1/2 UP 15-29 SU 007-SF5 006-BC4-1 36 UP 15-29 SU/LC 1 1/4" U 5 7/8 UP 15-29 SUC/TLC 003-BC4-1PNP UP 15-42 B7 39 UP 15-42 BUC7 40 UPS 15-55 SUC 47 008-BC6 3/4" sweat UPS 15-55 SFC 47 UP 26-99 BF 56 UPS 26-99 BFC 57 UP 26-116 BF (230V) 58 UPS 26-150 SF 60 UP 43-44 BF 61 6 6 3/8 008-BC6-IFC 1 1/4" U Flange 5 7/8 6 1/2 6 3/8 Flange 6 1/2 0011-BF4, 0011-SF4, 0011-SF4--IFC, 0014-BFI, 0014-BF-IFC, 0014-SF1, 0014-SF-IFC Flange 6 1/2 0013-BF3, 0013-BF-IFC, 0013-SF3, 0013-SF-IFC Flange 6 1/2 Flange UPS 43-44 BFC 006-BC4-3PNP 0012-BF4 Flange 8 1/2 0010-BF2, 0010-BF-IFC, 0010-SF3, 0010-SF3-IFC Flange 6 3/8 0012-BF-IFC, 0012-SF4, 0012-SF-IFC Flange 8 1/2 8 1/2 62 Cross reference UP Series Reference for replacing TACO models (continued) UPS 26-99 BFC 57 Flange 6 1/2 1400-10B Flange 6 3/8 Flange 6 3/8 UPS 26-150 SF 60 Flange 6 1/2 1400-20B, 1400-30B, 1400-40B, 1400-45B, 1400-50B UPS 43-100 SF 65 Flange 8 1/2 1400-60B Flange 8 1/2 UPS 50-60 SF 68 Flange 8 1/2 1400-65B Flange 8 1/2 UPS 43-44 BFC 62 Flange 8 1/2 111B 110B 6 5/16 Flange 113B UPS 43-100 SF UPS 50-60 SF 65 68 Flange Flange 8 1/2 8 1/2 8 1/2 112B, Flange 120B Flange 121B, 122B 131B, 132B 8 3/4 Flng-R 6 3/8 11 11 1/8 13 5/8 Closed systems: Cast iron body pumps UP 15-42 FC/MR 44 Flange 6 1/2 008-VDTF6 Flange 6 3/8 UPS 15-58 FC 50 Flange 6 1/2 005-F2, 005-F2-2IFC Flange 6 3/8 UP 15-10 FR 32 Flng-R 6 1/2 Flng-R 6 3/8 006-F4 006-F4-IFC UPS 15-58 FRC 50 UPS 15-58 FC 50 Flange 6 1/2 00R-MSF1-IFC, 007-F5, 008-F6 Flange 6 3/8 UP 15-100 F 51 Flange 6 1/2 009-F5 Flng-R 6 3/8 UP 26-64 F 52 UPS 26-99 FC 57 Flng-R 6 1/2 UP 26-116 F (230 V) 58 UPS 26-150 F 60 Flange 6 1/2 0011-F4, 0011-F4-2IFC, 0013-F3, 0013-F3-1IFC, 0014-F1,0014-F1-IFC Flng-R 6 1/2 UPS 43-44 FC 62 Flange 8 1/2 0010-F3, 0010-F3-IFC, 0012-F4, 0012-F4-IFC Flange 6 3/8, 8 1/2 UPS 26-99 FC 57 Flange 6 1/2 1400-20,1400-30, 1400-40, 1400-45, 1400-50 Flange 6 3/8 007-F5-8IFC, 008-F6-1IFC 0014-F Flange 6 1/2 0014-F 0013-F 1400-10 UPS 26-150 F 60 UPS 43-100 F 65 Flange 8 1/2 1400-60 Flange 8 1/2 UPS 50-60 F 68 Flange 8 1/2 1400-65 Flange 8 1/2 UPS 43-44 FC 62 Flange 8 1/2 111 110 6 5/16 Flange 113 UPS 43-100 F UPS 50-60 F 65 68 Flange Flange 8 1/2 8 1/2 8 1/2 112 Flange 120 Flange 121, 122 131, 132 8 3/4 Flng-R 6 3/8 11 11 1/8 13 5/8 * Grundfos provides no guarantee as to the accuracy of competitor information listed herein. 7 Cross reference UP Series Reference for replacing Bell & Gossett models Competitor cross-reference Open systems: Stainless steel and bronze body pumps Grundfos Primary model(s) UP 15-10 B5 Bell & Gossett* Page Conn. type 30 1/2" sweat Pump length Model [inches] Conn. type Pump length [inches] NBF-8S/LW 1/2" sweat 5 5 7/8 NBF-9U/LW 3/4"NPT, 1/2 & 3/4" sweat 6 1/8 NBF-10S/LW 1/2" sweat 5 1 1/4" U 6 1/8 3/4"NPT, 1/2 & 3/4" sweat 6 1/8 5 UP 15-29 SU 36 1 1/4" U UP 15-18 B5 34 1/2" sweat 5 UPS 15-35 SUC 38 1 1/4" U 5 7/8 NBF-9U/LW, NBF-12U/LW, SSF-12U/LW UPS 15-35 SUC/TLC 38 1 1/4" U 5 7/8 NBF-9U/TP, SSF-19U/TP NBF-12F/LW, SSF-12F/LW UPS 15-35 SFC 38 Flange 6 1/2 UP 15-42 B5 39 1/2" sweat 5 UPS 15-55 SUC 47 1 1/4" U 5 7/8 UPS 15-55 SFC 47 Flange 6 1/2 UP 26-96 BF 54 Flange 6 1/2 UPS 26-99 BF 56 Flange 6 1/2 NBF-18S NBF-22U, SSF-22U, NBF-18SU Flng-R 6 3/8 1/2" sweat 5 3/4"NPT, 1/2 & 3/4" sweat 6 1/8 NBF-22, NSF-22 Flng-R 6 3/8 LR-15B, NBF-25 Flange 6 3/8 Series PR B Flng-R 8 1/2 PL-30B Flange 6 3/8 Series PR B Flng-R 8 1/2 PL-30B, LR-15BWR, NBF-36 Sp-1 & 2, NBF-45 Sp-1, Series 100 Flange 6 3/8 UP 26-116BF (230 V) 58 Flange 6 1/2 PL-36B Flange 6 1/2 UPS 26-150SF 60 Flange 6 1/2 PL-36B, PL-55B, NBF-36 Sp-2 & 3, NBF-45 Flange 6 3/8, 8 1/2 UP 43-44 BF 61 Flange 8 1/2 Series HV B Flng-R 8 1/2 UPS 43-44 BF 62 Flange 8 1/2 LR-15BWR, NBF-33 8 1/2 PL-45B, PL-50B, NBF-36 Sp-2 & 3, NRF(NBF)-45 Sp-2 & 3 Flange 8 1/2 8 1/2 PL-50B, PL-75B, PL-130B Flange 8 1/2 NRF-9F/LW Flng-R 6 3/8 NRF-22 Flng-R 6 3/8 NRF-22, LW020WR, NRF9F/LW NRF-25 Sp-1 & 2 Flange 6 3/8 UPS 43-100 SF 65 Flange UPS 50-60 SF 68 Flange 6 3/8 Closed systems: Cast iron body pumps UP 15-10 FR 32 Flng-R 6 1/2 UP 15-42 FR 42 Flng-R 6 1/2 UPS 15-58 FRC 50 Flng-R 6 1/2 UP 15-42 FR 42 Flng-R 6 1/2 UPS 15-58 FRC 50 Flng-R 6 1/2 UP 15-42 F 42 Flange 6 1/2 UPS 15-42 F 43 Flange 6 1/2 UPS 15-58 FC 50 Flange 6 1/2 UP 26-64 F 52 Flange 6 1/2 Series PR Flng-R 8 1/2 UP 26-64 F 52 Flange 6 1/2 PL-30 Flange 6 3/8 UPS 26-99 FC 57 Flange 6 1/2 Series 100, PL-30, PR, NRF-36 Sp-1 & 2, NRF-45 Sp-1 & 2, LR-20WR Flange UP 26-116 F (230 V) 58 Flange 6 1/2 PL-36 Flange UPS 26-150 F 60 Flange 6 1/2 PL-36, PL-55, NRF-36 Sp-2 & 3, NRF-45 Flange 6 3/8 UP 43-44 F 61 Flange 8 1/2 Series HV, NRF-33 Flng-R 8 1/2 UPS 43-44 FC 62 Flange 8 1/2 LR-20WR, NRF-33, Series HV Flange 6 3/8 8 1/2 PL-45, PL-50, NRF-36 Sp-2 & 3, NRF-45 Sp-2 & 3 Flange 8 1/2 UPS 43-100 F 65 Flange UPS 50-44 F 67 2" Flng 8 1/2 2", PL-75 UPS 50-60 F 68 Flange 8 1/2 PL-50, PL-75, PL-130 * Grundfos provides no guarantee as to the accuracy of competitor information listed herein. 8 6 3/8 2" Flng-R, Flng 8 1/2 Flange 8 1/2 Cross reference UP Series Reference for replacing Laing models Competitor cross-reference Open systems: Stainless steel and bronze body pumps Comparable Grundfos replacement options Model(s) Page Laing pumps* Conn. type Pump length Model [inches] UP 15-18 B5 UP 15-18 B5/LC Pump length [inches] 1/2" sweat 6 3/4" sweat 6 SM-909-BS-1/2-14 34 1/2" sweat 5 SM-909-BSW-1/2-14 SMT-909-BS-1/2-14, SMT-909-BSW-1/2-14 UP 15-18 B5/TLC UP 15-18 B7 Conn. type SM-909-BS 3/4-14 34 3/4" sweat 6 3/8 UP 15-18 B7/TLC 34 3/4" sweat 6 3/8 SMT-909-BS 3/4-14, SMT-909-BSW-3/4-14 UPS 15-35 SFC 38 Flange 6 1/2 SM-909-BF14 Flange 6 1/2 UPS 15-55 SFC 47 Flange 6 1/2 SM-909-BF14, SM-909-BF18 Flange 6 1/2 UP 15-18 B7/LC SM-909-BSW 3/4-14 * Grundfos provides no guarantee as to the accuracy of competitor information listed herein. 9 Cross reference UP Series Reference for replacing Armstrong models Competitor cross-reference Open systems: Stainless steel and bronze body pumps Comparable Grundfos replacement options Primary model(s) Armstrong pumps* Pump length [inches] Conn. type Pump length Astro 20B050S 1/2" sweat 5 Astro 20B050S-LC 1/2" sweat 5 Page Conn. type 1/2" sweat 5 30 1/2" sweat 5 UP 15-10 B5/TLC 1/2" sweat 5 Astro 20B050S-T 1/2" sweat 5 UP 15-10 B7 3/4" sweat 6 3/8 Astro 20B075S 3/4" sweat 5 3/4" sweat 6 3/8 Astro 20B075S-LC 3/4" sweat 5 3/4" sweat 6 3/8 Astro 20B075S-T 3/4" sweat 5 1 1/4" U 6 1 1/4" U 6 UP 15-10 B5 UP 15-10 B5/LC UP 15-10 B7/LC 30 UP 15-10 B7/TLC Model UPS 15-35 SUC 38 Union 5 7/8 Astro 20BU, Astro 25BU, Astro 220SSU, Astro 225SSU UPS 15-35 SUC/TLC 38 Union 5 7/8 Astro 20BU, Astro 25BU, Astro 20BU-LC, Astro 20BU-T UPS 15-35 SFC 38 Flange 6 1/2 Astro 25BF Flange 6 3/8 UPS 15-55 SFC 47 Flange 6 1/2 Astro 30B, Astro 30B-3, Astro 230SS Flange 6 3/8 UP 26-96 BF 54 Flange 6 1/2 E7B Flange 6 3/8 E7B, Astro 50B, Astro 50B-3 Flange UPS 26-99 BFC 57 Flange 6 1/2 UPS 26-150 SF 60 Flange 6 1/2 UPS 43-44 BFC 62 Flange 8 1/2 UPS 43-100 SF 65 Flange 8 1/2 UPS 50-60 SF 68 Flange 8 1/2 H-41B E8B Flange E10B, E11B, E13B, E15B E16B, H-32B Flange 8 1/2 6 1/2 Flange H-51B, H-52B E19B, E28B, E29B, E30B, S-35B 6 3/8 8 1/2 S-25B E17B 6 3/8 8 1/2 8 1/2 11 1/2 Flange 8 1/2 Closed systems: Cast iron body pumps UP 15-10 F 32 Flange 6 1/2 Astro 20F Flange 6 3/8 UPS 15-58 FRC 50 Flange 6 1/2 Astro 230CI-R Flange 6 3/8 UPS 15-58 FC 50 Flange 6 1/2 Astro 30, Astro 30-3, Astro 230CI Flange 6 3/8 E7, Astro 50, Astro 50-3 Flange UPS 26-99 FC 57 Flange 6 1/2 UPS 26-150 F 60 Flange 6 1/2 UPS 43-44 FC 62 Flange 8 1/2 UPS 43-100 F 65 Flange 8 1/2 UPS 50-60 F 68 Flange 8 1/2 H-41 E8 E17 Flange 8 1/2 6 1/2 Flange H-51, H-52 E19, E28, E29, E30, S-35 6 3/8 8 1/2 S-25 * Armstrong pump information taken from literature on Armstrong website August 2002. Grundfos provides no guarantee as to the accuracy of competitor information listed herein. 10 Flange E10, E11, E13, E15 E16, H-32 6 3/8 8 1/2 8 1/2 11 1/2 Flange 8 1/2 Cross reference UP Series Discontinued products The table shows which new products replace discontinued products. Stainless steel, flanged 115 V Old model Product number New model UP 15-18SF 59896125 UP 15-29SF Product number 59896771 UP 15-42SF 59896171 UPS 15-35SFC 59896772 UPS 15-55SFC 59896773 UPS 15-42SF 59896247 UP 25-64SF 52722322 UP 15-18SU 59896127 UP 15-29SU 59896775 UP 15-18SU/LC 59896231 UP 15-29SU/LC 59896776 UP 15-18SU/TLC 59896232 UP 15-29SU/TLC 59896777 UPS 15-35SUC 59896778 UPS 15-35SUC/LC 59896779 Stainless steel, union 115 V UP 15-42SU UPS 15-42SU, UP 25-64 SU 59896174 59896130, 52722322 UPS 15-35SUC/TLC 59896780 UPS 15-55SUC 59896781 UPS 15-55SUC/LC 59896782 UPS 15-55SUC/TLC 59896783 Stainless steel, union 230 V UP 15-18SU 59896130 UP 15-29SU 59896784 UP 15-42SU 59896172 UP 15-35SUC 59896785 UP 25-64SU 52722323 UP 15-55SUC 59896786 11 Performance ranges UP Series 3-speed H UPS [ft] 45 60 Hz 40 UPS 26-150 35 30 25 20 15 UPS 15-58 10 5 0 5 10 15 20 25 30 35 40 45 50 55 Q [US GPM] TM04 5461 UPS 26-99 0 H UPS [ft] 60 Hz 30 UPS 43-100 25 20 UPS 50-60 15 10 5 0 0 10 20 30 40 50 60 70 80 90 100 110 120 130 Q [US GPM] 12 TM04 5460 UPS 43-44 Performance ranges UP Series 3-speed stainless steel H UPS [ft] 18 60 Hz 16 14 UPS 15 55 12 10 8 6 UPS 15 35 4 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q [US GPM] TM04 5462 2 Comfort Pump H [ft] a. UP 10-16 B5 b. UP 10-16 BN5 5.0 b 4.5 4.0 a 3.5 3.0 2.5 2.0 1.5 0.5 0.0 0.0 0.4 0.8 1.2 1.6 2.0 2.4 2.8 3.2 3.6 4.0 Q [GPM] TM03 8851 2807 1.0 Note: a. UP 10-16 B5 b. UP 10-16 BN5 13 Performance ranges UP Series Closed systems H [ft] 36 1. 2. 3. 4. 5. 6. 7. 8. 9. 1 32 2 28 4 24 UP 26-116 F UP 26-99 F UP 43-75 F UP 26-96 F UP 26-64 F UP 15-42 F UP 15-10 F/FR UP 15-100 F UP 26-120 U 5 20 3 8 16 6 12 8 0 0 4 8 12 16 20 24 28 32 36 40 44 Q [US GPM] TM03 9128 3407 9 7 4 Open systems H [ft] 32 10. UP 26-99 BF 11. UP 43-75 BF 12. UP 26-96 BF 13. UPS 15-55 SU/SF 14. UPS 15-35 SU/SF 15. UP 15-29 SU/SF 16. UPS 26-99 BFC 17. UPS 43-44 BFC 10 28 11 24 16 20 13 16 12 17 12 14 4 0 0 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60 64 Q [US GPM] 14 TM03 9129 3507 15 8 Performance ranges UP Series Open systems 1/2" H [ft] 1. UP 15-42 B5 2. UP 15-18 B5 3. UP 15-10 B5 4. UP 15-42 BUC5 5. UP 15-18 BUC5 6. UP 15-10 BUC5 4 15 14 13 12 11 10 9 8 1 7 6 5 5 4 2 3 3 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 Q [US GPM] TM03 9131 3507 6 2 Open systems 3/4" H [ft] 7. UP 15-42 B7 8. UP 15-18 B7 9. UP 15-10 B7 10. UP 15-42 BUC7 11. UP 15-18 BUC7 12. UP 15-10 BUC7 15 14 13 12 11 11 8 10 9 8 7 6 12 5 9 4 7 10 3 1 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 Q [US GPM] TM03 9132 3507 2 15 Product range UP Series Cast iron Product number 115 V 230 V Flow [gpm] Head [ft] Flanged UP 15-10 F 59896248 - 0-8 0-5 z UP 15-10 FR 59896249 - 0-8 0-5 z UP 15-42 FC/MR* 59896804 - 0-16 0-14 z UP 15-42 F 59896155 59896173 0-17 0-15 z 42 UP 15-42 FR 59896167 59896274 0-17 0-15 z 42 UP 15-42 F/VS* 59896807 - 0-16 0-15 z 45 - 59896180 0-17 0-16 z UPS 15-58 FC 59896341 - 0-17 0-19 z z 50 UPS 15-58 FRC 59896343 - 0-17 0-19 z z 50 UP 15-100 F 59896300 - 0-8.5 0-33 z 51 UP 26-64 F 52722330 52722327 0-32 0-24 z 52 UP 26-64 F/VS* 52722553 - 0-34 0-24 z 53 UP 26-96 F 52722341 52722338 0-27 0-30 z 54 UP 26-96 F/VS* 52722552 - 0-32 0-30 z 55 UP 26-99 F 52722355 52722351 0-34 0-32 z UPS 26-99 FC 52722512 52722513 UP 26-116 F - 52722377 0-38 0-37 UP 26-120 U 52722435 52722436 0-19 0-38 UPS 26-150 F 95906630 95906631 0-51 0-45 z UP 43-44 F 52722437 52722438 0-64 0-13 z UPS 43-44 FC 52722514 52722515 UP 43-70 F 96439644 - 15-85 1-24 z 63 UP 43-75 F 52722373 52722372 0-40 0-26 z 64 UPS 43-100 F 95906636 95906637 0-65 0-31 z 65 UP 43-110 F 96439643 - 0-90 1-37 z 66 UPS 50-44 F 52722557 52722558 0-65 0-14 z 67 UPS 50-60 F 97523134 97523135 0-125 0-21 z 68 UP 50-75 F 52722352 52722353 0-40 0-25 z 69 Closed systems UPS 15-42 F * Note: VS - variable speed, MR - MixiMizer, SU7P 16 Union NPT Sweat Check valve 32 32 z 44 43 56 z z z 57 58 z z Page 59 60 61 z 62 Product range UP Series Bronze Open systems Product number 115 V 230 V Flow [gpm] Head [ft] Flanged Union NPT Sweat Check valve Timer Line cord z UP 10-16 B5/LC 96433894 - 0-3 0-5 z UP 10-16 B5/TLC 96433895 - 0-3 0-5 z z z z Aqua Stat 29 z 29 z UP 10-16 B5/ATLC 96433896 - 0-3 0-5 UP 10-16 BN5/LC 96433897 - 0-3 0-5 z UP 10-16 BN5/TLC 96433898 - 0-3 0-5 z z z UP 10-16 BN5/ATLC 96433899 - 0-3 0-5 z z z z UP 10-16 BU/ATLC 96433902 - 0-3 0-5 z z z UP 15-10 B5 59896213 - 0-9 0-6 z z z z UP 15-10 B5/LC 59896214 - 0-9 0-6 z UP 15-10 B5/TLC 59896215 - 0-9 0-6 z UP 15-10 B7 59896226 - 0-9 0-6 z UP 15-10 B7/LC 59896209 - 0-9 0-6 z z z z 59896210 - 0-9 0-6 59896225 - 0-9 0-6 z z UP 15-10 BUC5/LC 59896237 - 0-9 0-6 z z UP 15-10 BUC5/TLC 59896238 - 0-9 0-6 z z UP 15-10 BUC7 59896241 - 0-9 0-6 z z UP 15-10 BUC7/LC 59896239 - 0-9 0-6 z z UP 15-10 BUC7/TLC 59896240 - 0-9 0-6 z z UP 15-18 B5 59896114 59896118 0-15 0-14 59896211 - 0-15 0-14 z - 0-15 0-14 z UP 15-18 B7 59896121 59896119 0-15 0-14 z UP 15-18 B7/LC 59896229 - 0-15 0-14 z 29 29 29 z 30 z 30 z 30 z 30 31 z z 31 z 31 31 z z z z 59896212 29 30 UP 15-10 B7/TLC UP 15-18 B5/LC 29 30 UP 15-10 BUC5 UP 15-18 B5/TLC Page 31 31 34 z z 34 z 34 z 34 z 34 34 z z UP 15-18 B7/TLC 59896230 - 0-15 0-14 UP 15-18 BUC5 59896123 - 0-12 0-16 z z 35 UP 15-18 BUC7 59896124 - 0-12 0-16 z z 35 UP 15-42 B5 59896145 59896142 0-17 0-15 z UP 15-42 B5/LC 59896233 - 0-17 0-15 z UP 15-42 B5/TLC 59896234 - 0-17 0-15 z UP 15-42 B7 59896146 59896149 0-17 0-15 z 39 z z z 39 39 39 UP 15-42 B7/LC 59896235 - 0-17 0-15 z UP 15-42 B7/TLC 59896236 - 0-17 0-15 z UP 15-42 BUC5 59896150 - 0-16 0-15 z z 40 UP 15-42 BUC7 59896151 - 0-16 0-15 z z 40 UP 15-42 BUC5/MR* 59896805 - 0-8 0-14 z z 41 UP 15-42 BUC7/MR* 59896806 - 0-14 0-15 z z UP 26-96 BF 52722336 52722334 0-27 0-30 z z z 39 z 39 41 54 UP 26-99 BF 52722347 52722346 0-34 0-32 z UPS 26-99 BFC 52722518 52722519 0-33 0-29 z UP 26-116 BF - 52722393 0-38 0-37 z 58 UP 43-44 BF 52722439 52722440 0-64 0-13 z 61 UPS 43-44 BFC 52722520 52722521 0-63 0-13 z UP 43-75 BF 52722370 52722369 0-45 0-26 z 56 z z 57 62 64 * Note: MR - MixiMizer 17 Product range UP Series Stainless steel Open systems UP 15-10 SU7P/TLC* UP 15-29 SF Product number 115 V Flow [gpm] Head [ft] 595916 - 0-3 0-3 59896771 - 0-22 0-10 Flanged Union NPT z Sweat Check valve z Timer Line cord z z z Page 33 36 UP 15-29 SU 59896775 59896784 0-22 0-10 z UP 15-29 SU/LC 59896776 - 0-22 0-10 z UP 15-29 SUC/TLC 59896777 - 0-22 0-10 z z - 59896785 0-22 0-12 z z z 38 z z 38 UP 15-35 SUC z 36 z z z 36 36 37 UPS 15-35 SFC 59896772 - 0-22 0-12 UPS 15-35 SUC 59896778 - 0-22 0-12 UP 15-35 SUC/TLC 59896780 - 0-22 0-12 z z - 59896786 0-25 0-18 z z z 47 z z 47 z z UP 15-55 SUC UPS 15-55 SFC 59896773 - 0-25 0-18 UPS 15-55 SUC 59896781 - 0-25 0-18 UPS 15-55 SUC/TLC 59896783 - 0-25 0-18 UPS 26-150 SF 95906632 95906633 0-51 0-47 z z z z 38 46 z z 47 60 UPS 43-100 SF 95906638 95906639 0-68 0-33 z 65 UPS 50-60 SF 97523136 97523137 0-125 0-21 z 68 * Note: Comfort system with 3/4" MXF NPT 18 230 V Identification UP Series Type key Example UP S 15 -58 () F C / Circulator pump S: 3 speed 10: Comfort series 15: Small stator UP 25, 26, 43, 50: Large stator UP Maximum head [dm] Pump housing = Cast iron (no letter = cast iron) S = Stainless steel B = Bronze Pipe connection F = Flange FR = Flange rotated 90° U = Union connection 5 = 1/2" internal sweat 7 = 3/4" internal sweat N = NPT female thread fitting 7P = 3/4" male x female connection Special features A = Thermostat (Aquastat) C = Check valve (removable) /T = Timer /LC = Line cord /TLC = Timer Line cord /VS = Variable speed control /MR = Mixing reset control 19 Identification UP Series Nameplate NONSUBMERSIBLE CIRCULATION PUMP Type UP 15 - 42F P/N: 59896155 115 V 1PH PC: 0452 P1 60Hz US 10uF Class F IMPEDANCE PROTECTED I1/1 (A) P1 (W) .74 85 - FOR NDOOR USE ONLY MAX FLUID TEMP. 230F 99K4 C UL US LISTED NONSUBMERSIBLE CIRCULATION PUMP Type UP 15 - 42F P/N: 59896155 115 V 1PH PC: 0452 P1 60Hz US 10uF Class F MPEDANCE PROTECTED I1/1 (A) P1 (W) .74 85 - FOR NDOOR USE ONLY MAX FLUID TEMP. 230F 10 11 12 13 14 15 TM03 8595 2007 1 2 3 4 5 6 7 8 9 99K4 C UL US LISTED Fig. 1 Nameplate Pos. 20 Description 1 Non-submersible pump 2 Pump type 3 Pos. Description 9 Approval UP 15-42F 10 Product number Voltage 115 V 11 04 = year 2004 / 52 = week 4 Frequency 60 Hz 12 Manufactured country 5 Capacitor 10 μF 13 Insulation, Class 6 1-phase 14 Impedance-protected 15 Maximum liquid temperature 7 Power 85 W 8 Current 0.74 A 59896155 F 230° F Applications UP Series The Grundfos circulator pumps, Series UP(S), are specifically designed for heating systems. The pumps are also suitable for circulation of hot domestic water and for circulation of liquid in cooling and airconditioning systems. Construction Heating systems The pumps are characterized by: Common uses: • Ceramic shaft and radial bearings • Boiler/hydronic heating • Carbon thrust bearing • Ground-source heat pumps • Stainless steel rotor can and bearing plate • Radiant floor heating • Impeller in corrosion-resistant material • Hydronic and fan-coil heating • Pump housing in cast iron, bronze or stainless steel. The UP(S) pumps are of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. • Solar heating • Heat recovery/heat pumps. Pump types with cast iron housing are generally used for these applications, considered to be closed systems pumping water or water/glycol mixtures. However, when water conditions exist that are not compatible with cast iron, we recommend the use of bronze or stainless steel. Optional variable-speed and mixing-reset controls are available to customize heat output vs heat demand for increased comfort. Domestic hot-water systems Common uses: • Solar water heating • Hot-water recirculation • Domestic hot-water heating. Pump types with bronze, brass or stainless steel housing are used for these applications, considered to be open systems pumping potable water. Optional timer and thermostat controls are available to limit pump operation to periods when hot water is required and to save energy. Cooling systems Common uses: • Chilled-water pumping. Pump types UP(S) 25, 26, 43, 50 and pump housings compatible with the pumped liquids are recommended for chilled water due to their motor construction, which is suitable for 32 °F (0 °C) water. 21 Applications Materials of construction Installation Description (UP closed systems) The pump must always be installed with horizontal motor shaft. Stator housing Aluminium Shaft, upper and lower radial bearings Aluminium oxide ceramic Thrust bearing Carbon bearing and EPDM retainer Check valve ACETAL with 302 stainless steel spring and nitrile rubber seats Pump housing (volute) Cast iron O-ring and gaskets EPDM (ethylene propylene rubber) Impeller PES composite (30 % glass-filled) Terminal box Noryl® with EPDM gasket Description (UP open systems) Material Inlet cone, bearing plate, bearing retainers, rotor can, rotor Stainless steel cladding, shaft retainer Volute retainer (SU & SF models) Aluminium and stator housing Shaft, upper and lower radial bearings Aluminium oxide ceramic Thrust bearing Carbon bearing and EPDM retainer Pump housing (volute) Silicon bronze C875 or stainless steel 300 series. O-ring and gaskets EPDM (ethylene propylene rubber) Impeller PES composite (30 % glass-filled) Terminal box Noryl® with EPDM gasket Description (BUC5 and BUC7) Material Inlet cone, bearing plate, bearing retainers, rotor can, rotor Stainless steel cladding, shaft retainer, check valve spring Stator housing Aluminium Shaft, upper and lower radial bearings Aluminium oxide ceramic Thrust bearing Carbon bearing and EPDM retainer Pump housing (volute) Silicon bronze C875 lead free Tail piece and union nut Brass (UNS C36000) O-ring and gaskets EPDM (ethylene propylene rubber) Impeller PES composite (30 % glass-filled) Terminal box Noryl® with EPDM gasket Check valve housing, valve and torpedo ACETAL with 302 stainless steel, spring and nitrile rubber seat Union gasket EPDM Proper installation of the pump will have the terminal box located to one side of the pump or the other, with the conduit entry down. UP(S) can be installed in both vertical and horizontal lines. UP(S) pumps are intended for indoor use only. TM04 5058 2509 Material Inlet cone, bearing plate, bearing retainers, rotor can, rotor Stainless steel cladding, shaft retainer 22 UP Series Fig. 1 Motor The motor is a 2-pole asynchronous squirrel-cage PSC (permanent split capacitor) motor with UL, CUL, ETL and CSA approvals. UP(S) pumps are available in single-phase 115 V and 230 V versions with one or three speeds. The terminal box is easily accessible and has functional cable connecting leads or terminals. Insulation class(es): F, H. The motor incorporates thermal overload or impedance protection. Therefore, no external motor protection is required. UP models are single speed. UPS model pumps are multi-speed, and the speed can be changed by a speed selector switch located on the front of the terminal box. If the speed of UPS 15-35 or 15-55 TLC models has to be changed, the timer control has to be removed before the speed can be changed. UP models with VS or MR suffixes are variable speed with integrated control. Depending on pump model, motor horsepowers range from 1/25 to 1/6 and power consumption from 5 to 385 W. Applications UP Series Pumped liquids The ambient temperature for standard pumps with a permissible liquid temperature from 36 °F (2 °C) to 230 °F (110 °C) should always be lower than the liquid temperature, as otherwise condensation may form in the stator housing. Depending on type, Grundfos circulator pumps are designed for the following liquids: • Potable water • Non-potable water • Water/glycol mixtures Maximum system pressure • Chilled water 145 psi (10 bar). • Domestic-hot water • Softened water. Minimum inlet pressure If the circulator pump is used for a glycol mixture with a higher viscosity than that of water, the hydraulic performance of the pump will be reduced. The amount of pressure required at the inlet of a pump is a function of the temperature of the water as shown in the table below. Example: 50 % glycol at 68 °F (20 °C) means a viscosity of approx. 10 cSt and a reduction of pump performance by approx. 15 %. Liquid temperature UP(S) model When selecting a pump, the viscosity of the pumped liquid must be taken into consideration. 140 °F (60 °C) 230 °F (110 °C) [psi] [bar] [psi] [bar] [psi] [bar] [psi] [bar] UP(S) 43 The maximum allowable water temperature is determined by the ambient or surrounding air temperature as shown in the table below. 190 °F (88 °C) UP(S) 15 UP(S) 26 Ambient and liquid temperatures 165 °F (74 °C) 1.9 1.3 0.1 4.0 0.3 15.6 1.1 0.1 UPS 26-150 1.3 0.09 2.6 0.18 7.8 0.54 UPS 43-100 2.1 0.15 5.6 0.40 11.3 0.80 1.0 0.07 1.3 0.09 7.0 0.49 UPS 50-60 0.5 0.04 Maximum water temperature Ambient (°F) 104 (40) 120 (49) 140 (60) 160 (71) 175 (79) Water, all cast iron (°F) 230 220 (110) (104) 210 (99) 190 (88) 175 (79) Water, all bronze and stainl. steel 220 (104) 190 (88) 175 (79) 210 (99) Performance Flow range 0 - 120 gpm, head range 0 - 46 feet In a pressure system, the required inlet pressure is the allowable system pressure. In a system open to the atmosphere, the required inlet pressure is the minimum distance the pump must be located below the lowest possible water level of the water source (tank, pool, etc.). *exceptions below UP/UPS 15 FC and UP 43 FC (°F) 200 (93) 190 (88) 180 (82) 170 (77) UP 15BUC5 and UP 15BUC7 (°F) 200 (93) 190 (88) 180 (82) 170 (77) UPS 15-35 (°F) 165 (74) 140 (60) - - - UP 15-100F (°F) 205 (96) 195 (91) 185 (85) 175 (79) - UP 26-120U (°F) 205 (96) 195 (91) 185 (85) 175 (79) - UP 26-116 (°F) 150 (66) 140 (60) - - - Note: This table refers to all standard product without timer/control options or other special features. • If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). • Temperature requirements for pumps with timer/ control or other special features may be found on their technical data page. 23 Applications ALPHA UP Series Control display The Grundfos Alpha is the next generation of energy efficient wet-rotor circulators. By incorporating a permanent magnet motor design, power consumption is now reduced by a minimum of 50 %. By using the AutoADAPT™ feature, Grundfos ALPHA will automatically analyze the system demands and adjust head and or flow requirements to meet changing heating demands. Standard features • Permanent magnet motor design • Easy push button hydraulic selection • Seven hydraulic selection options - Three fixed speeds - Three constant pressures - AutoADAPT™ • Easy to read LED display - Flow indicator (gpm) - Power consumption (watts) - Hydraulic selection • Nut capture flange • Metallurgical options Position - Cast iron (F or FR) 1 Watt or flow indicator 2 Three fixed speeds 3 Three constant pressure settings Additional technical data 4 AUTOADAPT Supply voltage: 1x115V +/-10 %, 60Hz 5 Push-button for selction of pump settings Motor protection: Pump requires none. - Stainless steel (F) • Line cord or conduit connection options Enclosure class: Insulation class: Indoor use only, IP42, Max. operating pressures CSA Enclosure Type 2 Liquid temp. Min. inlet press. 167 °F (75 °C) 0.75 psi (0.05 bar) 194 °F (90 °C) 4.06 psi (0.28 bar) 230 °F (110 °C) 15.7 psi (1.08 bar) F Relative air humidity: Maximum 95 % Max. discharge press.: 150 psi (10.34 bar) Sound pressure level: 43 dB (A) Ambient temp.: +32 °F (0 °C) to +104 °F (+40 °C) Liquid temp.: +36 °F (+2 °C) to +230 °F (+110 °C) Max. glycol concentrations: 50 % glycol @ 36 °F (2 °C) (Hydraulic performance change can be expected.) Max. operating temperatures Ambient temp. [°F (°C)] Liquid temp. Min. [°F (°C)] Max. [°F (°C)] +32 °F (0 °C) +36 °F (+2 °C) +230 °F (+110 °C) +50 °F (+10 °C) +50 °F (+10 °C) +230 °F (+110 °C) Provides a relative indication of flow — should not be used in lieu of a flow meter. +68 °F (+20 °C) +68 °F (+20 °C) +230 °F (+110 °C) +86 °F (+30 °C) +86 °F (+30 °C) +230 °F (+110 °C) Use of check valve may reduce pump hydraulic performance (up to -10%). +95 °F (+35 °C) +95 °F (+35 °C) +194 °F (+90 °C) Use check valve in parallel pumping applications. +104 °F (+40 °C) +104 °F (+40 °C) +158 °F (+70 °C) Watt readings: Accuracy +/-1 Watt Flow indicator: Check valve: 24 Description Applications UP Series The Grundfos MixiMizer, a fully integrated injection pump and indoor/outdoor controller, is the only pump and controller system of its kind. Equipped with a weather responsive control, also known as indoor/outdoor control or reset control, the MixiMizer automatically calculates and controls mixed water temperatures according to outdoor temperatures in primary/secondary piping systems. The control also provides pump exercising for 10 seconds every 3 days and a 20 second postpurge when the heat demand is removed. Standard features • Variable-speed output modulation • System supply-temperature sensor 140 °F (60 °C) max. • Boiler return-temperature sensor 135 °F (57 °C) min. • Heating curve can be adjusted by 5 °F in parallel • Pump exercising every three days of no operation. H [ft] 16 For maximum design flexibility, the MixiMizer can be integrated into a thermostat or zoning control system through the user-selectable "external call for heat/ demand input". d c b 14 12 10 A fully serviceable check valve integrated into the pump housing eliminates ghost flows in primary/secondary injection systems and zone applications. 8 6 LEDs located on the terminal box are designed to indicate performance and diagnose faults without tools. 4 2 Other standard user-selectable features include boiler protection, system/slab "overtemperature" control and a 5 °F parallel shift of the heating curve. a 0 0 2 4 6 8 10 12 14 16 18 Q [US GPM] TM03 8844 2607 MixiMizer - mixing reset pump Fig. 3 Family curves for MixiMizer Description a Min. curve for all models b Max. UP 15-42 BUC5 c Max. UP 15-42 BUC7 d Max. UP 15-42 FC TM04 9735 5110 Position Fig. 2 MixiMizer MixiMizer models includes the following: • Two water-temperature sensors (system supply and return) prewired, 8 ft (2.4 m) each • One prewired 6-foot line cord • One outdoor air-temperature sensor • Two flange gaskets • Optional zone control input • Optional boiler on/off output. 25 Applications UP Series Variable-speed pump H [ft] 32 d 28 If desired, the manual-% dial allows the speed of the pump to be manually adjusted and set by the user. The speed of the pump may be manually adjusted anywhere from min. to 100 %, but once set, remains fixed at that speed. 20 16 8 The control also provides pump exercising for 10 seconds every 3 days and a power-up reset, which runs the pump for 3 seconds at full speed, for all modes of operation. 4 a 0 0 TM03 9088 3307 • Line cord, 6-ft (1.8 m) prewired • Two gaskets. Variable-speed standard features • Variable-speed output modulation (external or manual control) • Offset-dial for fine-tuning of the signal input. 26 Signal type Signal range Voltage 0-10 VDC or 2-10 VDC, 5mA Max Current 0-20 mA or 4-20 mA, 5 VDC Max 4 8 12 16 20 24 28 32 36 Q [US GPM] LEDs on the terminal box indicate operation (power is applied) and performance (flashes slower or faster). Variable-speed models include the following • Pump with integrated variable-speed control b 12 In addition, the pump speed may be set as 0-100 % or 15-100 % by user. Fig. 4 Variable-speed pump c 24 Fig. 5 Family curves for variable-speed pumps Position Description a Min. curve for all models b Max. UP 15-42 F/VS c Max. UP 26-64 F/VS d Max. UP 26-96 F/VS TM03 8843 2607 The Grundfos variable-speed pump is another product with fully integrated control. The variable-speed controller requires a 0-10/2-10 DC or 0-20/4-20 mA control signal, which is user-selectable. Applications UP Series Comfort System The Comfort System uses a patented Comfort Valve® and pump to provide instant availability of hot water at the point of use. Operation The Comfort Valve® is installed at the furthest fixture from the hot-water tank. With a built-in timer, the pump allows hot water to circulate along the loop through the valve using the cold-water side as a return line. As the temperature rises to 100 °F (38 ° C), the valve closes directing hot water to the tap, resulting in a constant availability of hot water. Savings The Comfort System saves up to 16,000 gallons of water per year and per household (based on average modern household usage) and uses less energy than a 25 W light bulb. Applications • Domestic hot-water recirculation systems in singleand two-family houses. Pumped liquids • Domestic hot water Description (UP open systems) Material Inlet cone, bearing plate, bearing retainers, rotor can, rotor cladding, shaft retainer Stainless steel Volute retainer (SU & SF models) Aluminium and stator housing Shaft, upper and lower radial bearings Aluminium oxide ceramic Thrust bearing Carbon bearing and EPDM retainer Pump housing (volute) Silicon bronze C875 or stainless steel 300 series. O-ring and gaskets EPDM (ethylene propylene rubber) Impeller PES composite (30 % glass-filled) Terminal box Noryl® with EPDM gasket Ambient and liquid temperatures Liquid temperature: 36 °F (2 °C) to 150 °F (66 °C). It is recommended to keep the operating temperature as low as possible (e.g. 140 °F (60 °C)) to avoid calcium precipitation. The ambient temperature should always be lower than the liquid temperature, as otherwise condensation may form in the stator housing. Maximum system pressure 145 psi (10 bar). • Potable and non-potable water [ft] 5.0 4.5 4.0 3.5 3.0 2.5 2.0 1.0 0.5 0.0 0.0 Fig. 6 Comfort System Motor • Insulation class: F. 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 5.0 5.5 6.0 6.5 7.0 TM03 5547 3806 TM03 9126 3407 1.5 Q [GPM] Fig. 7 Performance curve for the Comfort System • Power consumption: 25 W. • Voltage: 115 V. • Current 0.23 A. • Phase: 1. 27 Applications UP Series UP 10 Comfort pump The water-conduction part of the pump is hermetically separated from the stator with a stainless steel spherical separator. The motor can be separated from the pump housing, enabling easy maintenance and replacement. Description Material Stator housing Aluminium Spherical separator Stainless steel Rotor can complete Stainless steel/tungsten carbide Rotor, impeller Stainless steel, EPDM, PPO, PFTE, graphite Pump housing Brass MS 58 Applications • Domestic hot-water recirculation systems in singleand two-family houses Isolation valve PPO Screw Stainless steel Terminal box cover, motor cover PA66/6 • Small heating systems. Light Lexan Pumped liquids • Domestic hot water • Non-potable water • Softened water. Cable, cable relief PVC Insulating cover EPP 55 O-rings EPDM Check valve POM Ambient and liquid temperatures Liquid temperature: 36 °F (2 °C) to 203 °F (95 °C). It is recommended to keep the operating temperature as low as possible (e.g. 140 °F (60 °C)) to avoid calcium precipitation. GrA3803 The ambient temperature should always be lower than the liquid temperature, as otherwise condensation may form in the stator housing. Fig. 8 Comfort pump Maximum system pressure 145 psi (10 bar). Inlet pressure To avoid cavitation noise and damage to the pump bearing at high temperatures, the following minimum pressures are required at the pump suction port. TM04 9805 0111 Liquid temperature Fig. 9 Comfort pump Motor • Insulation class: F. • Power consumption: 25 W. • Voltage: 115 V. • Phase: 1. 28 Inlet pressure 203 °F (95 °C) 185 °F (85 °C) 9 ft (2.8 m) 1.6 ft (0.5 m) 4.0 psi ( 3 bar) 0.7 psi (.05 bar) Technical data UP 10-16 B5/BN5 UP 10 Comfort Pump H [ft] a. UP 10-16 B5 b. UP 10-16 BN5 5.0 b 4.5 4.0 a Flow range: 0-3.5 gpm Head range: 0-5.4 feet Motors: Single-phase Max. liquid temperature: 203 °F (95 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 3.5 Model 3.0 Volts Amps Watts Hp Capacitor 115 0.23 25 - - UP 10-16 B5/BN5 2.5 Approvals 2.0 1.5 0.5 0.0 0.0 0.4 0.8 1.2 1.6 20 2.4 2.8 3.2 3.6 40 Q [GPM] TM03 8851 0211 1.0 TM03 4354 2006 UP 10-16 B5/BN5 TM03 4353 2006 UP 10-16 BU Dimensions [inches] Model type Product number L1 L2 H1 H2 H3 5 1/4 H4 Connection Shipping weight lbs B1 B2 3 3 1/3 1/2" sweat 2.9 UP 10-16 B5/LC 96433894 3 1/8 1 1/2 UP 10-16 B5/TLC 96433895 3 1/8 3 1/2 1 1/2 8 1/16 3 3 1/3 1/2" sweat 3.4 UP 10-16 B5/ATLC 96433896 3 1/8 3 1/2 1 1/2 8 1/16 3 3 1/3 1/2" sweat 3.4 UP 10-16 BN5/LC 96433897 3 1/8 1 1/2 3 3 1/3 1/2" F NPT 2.9 UP 10-16 BN5/TLC 96433898 3 1/8 3 1/2 1 1/2 8 1/16 3 3 1/3 1/2" F NPT 3.4 UP 10-16 BN5/ATLC 96433899 3 1/8 3 1/2 1 1/2 8 1/16 3 3 1/3 1/2" F NPT 3.4 UP 10-16 BU/ATLC 96433902 4 1/3 1 7/8 8 1/16 3 3 1/3 GF 125 union - 1 1/4" NPSM 3.8 5 1/4 Note: Dimensions in inches unless otherwise noted. 29 Technical data UP 15-10 B5/B7 H [ft] a. UP 15-10 B5 b. UP 15-10 B7 7 6 b a 5 Flow range: 0-8.2 gpm Head range: 0-6.2 feet Motors: 2-pole, single-phase Max. liquid temperature: 220 °F (104 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 4 Model 3 UP 15-10 B5 and B7 Amps Watts Hp Capacitor 115 0.22 25 1/25 2μF/400 V Approvals 0 1 2 3 4 5 6 7 8 9 Q [GPM] Model type Product number UP 15-10 B5/TLC TM03 8547 1907 UP 15-10 B7 and UP 15-10 B7/LC TM03 8545 1907 UP 15-10 B5 and UP 15-10 B5/LC UP 15-10 B7/TLC TM03 8546 1907 0 Dimensions [inches] A B C D E F TM03 8548 1907 1 TM03 8424 1507 2 Connection type and size Shipping weight [lbs] UP 15-10 B5 59896213 5 4 11/16 4 4 3 1/2 - 1/2" sweat 6 UP 15-10 B5/LC 59896214 5 6 3/16 5 1/2 4 3 1/2 4 1/2" sweat 6.5 UP 15-10 B5/TLC 59896215 5 6 3/16 5 1/2 4 3 1/2 4 1/2" sweat 6.5 UP 15-10 B7 59896226 6 3/8 5 1/8 4 3 13/16 3 1/4 - 3/4" sweat 6.7 UP 15-10 B7/LC 59896209 6 3/8 6 5/8 5 1/2 3 13/16 3 1/4 4 3/4" sweat 7.5 UP 15-10 B7/TLC 59896210 6 3/8 6 5/8 5 1/2 3 13/16 3 1/4 4 3/4" sweat 7.5 Note: LC/TLC models have a 6 ft (1.8 m), 3-prong power cord. Dimensions in inches unless o herwise noted. 30 Volts Technical data UP 15-10 BUC5/7 H [ft] 65 a a. UP 15-10 BUC5 b. UP 15-10 BUC7 60 55 b 50 Flow range: 0-6.6 gpm Head range: 0-6.6 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 45 Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 40 35 Model 30 Volts Amps Watts Hp Capacitor 115 0.22 25 1/25 2μF/400 V UP 15-10 BUC5/BUC7 25 Approvals 20 15 00 05 1.0 1.5 20 2.5 30 35 4.0 45 5.0 5.5 60 6.5 7.0 Q [GPM] UP 15-10 BUC7 and UP 15-10 BUC7/LC UP 15-10 BUC7/TLC TM03 8553 2407 UP 15-10 BUC5/TLC TM03 8549 2407 UP 15-10 BUC5 and UP 15-10 BUC5/LC TM03 8550 2407 0.0 Dimensions [inches] Model type TM03 8554 2407 05 TM03 8425 1507 10 Product number A B C D E F Connection type and size Shipping weight [lbs] UP 15-10 BUC5 59896225 6 1/2 5 1/4 4 3 1/5 3 1/4 - 1/2" sweat 7.25 lbs UP 15-10 BUC5/LC 59896237 6 1/2 6 3/4 5 1/2 3 3/16 3 1/4 4 1/2" sweat 7.7 UP 15-10 BUC5/TLC 59896238 6 1/2 6 3/4 5 1/2 3 3/16 3 1/4 4 1/2" sweat 7.7 UP 15-10 BUC7 59896241 7 3/4 5 1/4 4 3 3/4 3 1/4 - 3/4" sweat 8.0 lbs UP 15-10 BUC7/LC 59896239 7 3/4 6 3/4 5 1/2 3 3/4 3 1/4 4 3/4" sweat 8.5 UP 15-10 BUC7/TLC 59896240 7 3/4 6 3/4 5 1/2 3 3/4 3 1/4 4 3/4" sweat 8.5 Note: LC/TLC Models have 6 ft(1.8 m), 3-prong power cord. Dimensions in inches unless o herwise noted. 31 Technical data UP 15-10 F/FR H [ft] 6 5 Flow range: 0-8.0 gpm Head range: 0-5.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Closed system 4 Model 3 UP 15-10 F/FR Volts Amps Watts Hp Capacitor 115 0.23 25 1/25 2μF/400 V Approvals 2 TM03 5532 0907 1 0 0 1 2 3 4 5 6 7 8 9 Q [GPM] TM03 8527 1907 UP 15-10 FR TM03 8526 1907 UP 15-10 F Model type Product number A B C D E F Connection type and size Shipping weight [lbs] UP 15-10 F 59896248 6 1/2 5 1/4 4 4 3/16 3 1/4 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 7 1/4 UP 15-10 FR 59896249 6 1/2 5 15/16 4 3 3/4 3 1/4 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 7 1/4 Note: Dimensions in inches unless otherwise noted. 32 Technical data UP 15-10 SU7P/TLC UP Comfort System H [ft] 50 45 40 Flow range: 0-6.3 gpm Head range: 0-5.1 feet Motors: 2-pole, single-phase Max. liquid temperature: 150 °F (66 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Open system 35 Model 30 UP 15-10 SU7P/TLC Volts Amps Watts Hp Capacitor 115 0.23 25 1/25 2μF/400 V 25 Approvals 20 15 10 TM03 5547 3806 05 00 0.0 05 10 1.5 20 2.5 3.0 35 4.0 4.5 50 5.5 6.0 65 7.0 Q [GPM] Comfort Valve® TM03 4363 3507 TM03 4362 3507 UP 15-10 SU7P/TLC Dimensions [inches] Model type Product number A B C D E F Connection type and size Shipping weight [lbs] UP 15-10 SU7P/TLC 595916 5 7/16 6 1/4 5 1/2 3 7/16 3 1/4 4 3/4" M x 3/4" F NPT 5.5 Comfort Valve 595926 - - - - - - 1/2” M NPS (1/2” faucet) 2.8 Flex hose kit 599390 - - - - - - (2) 1/2" FNPS X 1/2" FNPS X 12" flex hoses - Model type Product number Description Comfort Valves 595926 Box of 15 pieces Comfort series kit 595916 1 pump and 1 valve, (2) 1/2" FNPS X 1/2" FNPS X 12" flex hoses Note: All models have a 10 ft (3 m), 3-prong power cord. Dimensions in inches unless o herwise noted. 33 Technical data UP 15-18 B5/B7 H [ft] 14 a. UP 15-18 B5 b. UP 15-18 B7 13 12 11 10 9 Flow range: 0-14.7 gpm Head range: 0-13.9 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 8 7 Model 6 Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V 230 0.4 90 1/25 2μF/400 V 115 0.74 85 1/25 10μF/180 V 230 0.4 96 1/25 2μF/400 V UP 15-18 B5 5 b 4 a UP 15-18 B7 3 2 1 Approvals 2 3 4 5 6 7 8 9 10 11 12 13 14 15 Q [GPM] UP 15-18 B7/LC UP 15-18 B7/TLC TM03 8546 1907 UP 15-18 B5/TLC TM03 8545 1907 UP 15-18 B5/LC Product number Dimensions [inches] Connection type and size Shipping weight [lbs] - 1/2" sweat 6 3 1/4 4 1/2" sweat 6.5 3 1/2 3 1/4 4 1/2" sweat 6.5 4 3 4/5 3 1/4 - 3/4" sweat 6.7 6 5/8 5 1/2 3 4/5 3 1/4 4 3/4" sweat 7.2 6 5/8 5 1/2 3 4/5 3 1/4 4 3/4" sweat 7.2 Model type 115 V 230 V A B C D E F UP 15-18 B5 59896114 59896118 5 4 11/16 4 3 1/2 3 1/4 UP 15-18 B5/LC 59896211 - 5 6 3/16 5 1/2 3 1/2 UP 15-18 B5/TLC 59896212 - 5 6 3/16 5 1/2 UP 15-18 B7 59896121 59896119 6 3/8 5 1/8 UP 15-18 B7/LC 59896229 - 6 3/8 UP 15-18 B7/TLC 59896230 - 6 3/8 Note: LC/TLC Models have 6 ft (1.8 m), 3-prong power cord. Dimensions in inches unless o herwise noted. 34 TM03 8548 1907 1 TM03 8547 1907 0 TM03 8426 1507 0 Technical data UP 15-18 BUC5/BUC7 H [ft] Flow range: 0-14.7 gpm Head range: 0-14.5 feet Motors: 2-pole, single-phase b Max. liquid temperature: 230 °F (110 °C) a Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) a. UP 15-18 BUC5 b. UP 15-18 BUC7 16 14 12 10 Model Volts Amps Watts Hp Capacitor UP 15-18 BUC5 115 0.55 60 1/25 8μF/180 V UP 15-18 BUC7 115 0.55 60 1/25 8μF/180 V 8 6 4 Approvals 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 Q [GPM] TM03 8553 2407 UP 15-18 BUC7 TM03 8549 1907 UP 15-18 BUC5 TM03 8428 1507 2 Dimensions [inches] Model type Product number A B C D E F Connection type and size Shipping weight [lbs] UP 15-18 BUC5 59896123 6 1/2 5 1/4 4 3 3/16 3 1/4 - 1/2" sweat 7 1/4 lbs UP 15-18 BUC7 59896124 7 3/4 5 1/4 4 3 3/4 3 1/4 - 3/4" sweat 8 lbs Note: Dimensions in inches unless otherwise noted. 35 Technical data UP 15-29 SU/SF H [ft] 10 Flow range: 0-20.5 gpm Head range: 0-9.7 feet Motors: 2-pole, single-phase 9 Max. liquid temperature: 230 °F (110 °C) and 150 °F 8 Min. liquid temperature: 36 °F (2 °C) 7 Max. system pressure: 6 Open system 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 5 4 Model Volts Amps Watts Hp 0.75 87 0.12 0.75 87 0.12 0.42 97 0.15 Capacitor 3 UP 15-29 SF 115 2 0 2 4 6 8 10 12 14 16 18 20 22 Q [GPM] UP 15-29 SU/LC Product number UP 15-29 SU/TLC Dimensions [inches] Model type Connection type and size Shipping weight [lbs] 115 V 230 V A B C D E F UP 15-29 SF 59896771 - 6 1/2 5 1/2 4 1/8 3 14/16 2 15/16 3 1/8 GF15/26 6.0 UP 15-29 SU 59896775 59896784 5 7/8 5 1/2 4 1/8 3 7/16 2 15/16 - GU125 5.4 UP 15-29 SU/LC 59896776 - 5 7/8 5 1/2 4 1/8 3 7/16 2 15/16 - GU125 5.7 UP 15-29 SUC/TLC 59896777 - 5 7/8 5 1/2 4 1/8 3 7/16 2 15/16 - GU125 6.2 Note: LC/TLC Models have 6 ft (1.8 m), 3-prong power cord. Dimensions in inches unless o herwise noted. 36 2μF/400 V Approvals TM03 8777 2507 UP 15-29 SU TM03 8776 2507 UP 15-29 SF 230 TM03 8777 2507 0 UP 15-29 SU 10μF/180 V TM03 8778 250 1 TM03 8847 2607 UP 15-29 SUC Technical data UP 15-35 SUC H [ft] 12 10 8 Flow range: 0-17.5 gpm Head range: 0-11.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Open system 6 Model UP 15-35 SUC 4 Volts Amps Watts Hp Capacitor 230 0.42 114 0.15 2μF/400 V Approvals 0 0 2 4 6 8 10 12 14 16 18 Q [GPM] TM03 8846 2607 2 TM03 87777 2507 UP 15-35 SUC Dimensions [inches] Model type UP 15-35 SUC Product number 59896785 A B C D E F 5 7/8 5 1/16 4 1/8 3 7/16 2 15/16 - Connection type and size Shipping weight [lbs] GU125 5.4 Note: Dimensions in inches unless otherwise noted. 37 Technical data UPS 15-35 SUC/SFC H [ft] 12 3 Flow range: 0-21.5 gpm Head range: 0-12 feet Motors: 2-pole, single-phase 11 Max. liquid temperature: 165 °F (74 °C) 10 Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 9 8 Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 2 7 6 Model Spd Volts Amps Watts 5 3 1 4 UPS 15-35 SUC/SFC 2 1 3 115 Hp Capacitor 0.95 110 0.15 0.75 84 0.11 10μF/180 V 0.55 61 0.08 1 0 0 2 4 6 8 10 12 14 16 18 20 22 24 Q [GPM] Without check valve With check valve Approvals TM03 8778 2507 UPS 15-35 SUC/TLC TM03 8779 2507 UPS 15-35 SFC TM03 8850 2607 2 Dimensions [inches] Model type Product number A B C D E F Shipping weight [lbs] UPS 15-35 SFC 59896772 6 1/2 5 1/2 4 1/8 3 7/8 2 15/16 3 1/8 GF15/26 6 UPS 15-35 SUC 59896778 5 7/8 5 1/16 4 1/8 3 7/16 2 15/16 - GU125 5.4 UPS 15-35 SUC/TLC 59896780 5 7/8 5 1/16 4 1/8 3 7/16 2 15/16 - GU125 6.2 Note: LC/TLC Models have 6 ft (1.8 m), 3-prong power cord. Removable check valve. Dimensions in inches unless o herwise noted. 38 Connection type and size Technical data UP 15-42 B5/B7 Flow range: 0-17 gpm Head range: 0-15 feet Motors: 2-pole, single-phase b Max. liquid temperature: 230 °F (110 °C) a Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) H [ft] a. UP 15-42 B5 b. UP 15-42 B7 16 14 12 Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 10 8 Model 6 UP 15-42 B5 Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V 230 0.41 95 1/25 2μF/400 V 4 115 0.74 85 1/25 10μF/180 V 230 0.41 95 1/25 2μF/400 V UP 15-42 B7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 Q [GPM] UP 15-42 B7/LC UP 15-42 B7/TLC TM03 8546 1907 UP 15-42 B5/TLC TM03 8545 1907 UP 15-42 B5/LC and B7 Product number TM03 8547 1907 0 Approvals Dimensions [inches] TM03 8548 1907 0 TM03 8430 1507 2 Connection type and size Shipping weight [lbs] - 1/2" sweat 6.0 3 1/4 - 1/2" sweat 6.5 3 1/2 3 1/4 - 1/2" sweat 6.5 4 3 4/5 3 1/4 - 3/4" sweat 6.7 6 5/8 5 1/2 3 4/5 3 1/4 - 3/4" sweat 7.2 6 5/8 5 1/2 3 4/5 3 1/4 - 3/4" sweat 7.2 Model type 115 V 230 V A B C D E F UP 15-42 B5 59896145 59896142 5 4 11/16 4 3 1/2 3 1/4 UP 15-42 B5/LC 59896233 - 5 6 3/16 5 1/2 3 1/2 UP 15-42 B5/TLC 59896234 - 5 6 3/16 5 1/2 UP 15-42 B7 59896146 59896149 6 3/8 5 1/8 UP 15-42 B7/LC 59896235 - 6 3/8 UP 15-42 B7/TLC 59896236 - 6 3/8 Note: LC/TLC Models have 6 ft (1.8 m), 3-prong power cord. Dimensions in inches unless o herwise noted. 39 Technical data UP 15-42 BUC5/BUC7 H [ft] a. UP 15-42 BUC5 b. UP 15-42 BUC7 16 14 Flow range: 0-17 gpm Head range: 0-15 feet Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 10 Model Volts Amps Watts Hp Capacitor UP 15-42 BUC5 115 0.74 85 1/25 10μF/180 V UP 15-42 BUC7 115 0.74 85 1/25 10μF/180 V 8 6 4 Approvals a b 0 0 2 4 6 8 10 12 14 16 18 Q [GPM] TM03 8753 2407 UP 15-42 BUC7 TM03 8549 1907 UP 15-42 BUC5 TM03 8431 1507 2 Dimensions [inches] Model type Product number B C D E F Connection type and size Shipping weight [lbs] UP 15-42 BUC5 59896150 6 1/2 5 1/4 4 3 3/16 3 1/4 - 1/2" sweat 6 1/2 UP 15-42 BUC7 59896151 7 3/4 5 1/4 4 3 3/4 3 1/4 - 3/4" sweat 6 3/4 Note: Dimensions in inches unless otherwise noted. 40 A Technical data UP 15-42 BUC5/MR and BUC7/MR UP 15 MixiMizer H [ft] a. MIN - bo h models b. MAX - UP 15-42 BUC5 c. MAX - UP 15-42 BUC 7 16 c Flow range: 0-13.5 gpm Head range: 0-15 feet Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 14 b 12 10 Model Volts Amps Watts Hp Capacitor UP 15-42 BUC5/MR 115 0.74 85 1/25 10μF/180 V UP 15-42 BUC7/MR 115 0.74 85 1/25 10μF/180 V 8 6 4 Approvals TM03 8839 2607 2 a 0 0 2 4 6 8 10 12 14 16 Q [ GP M] UP 15-42 BUC5/MR MixiMizer models include the following features: • Two water-temperature sensors (system supply and return (prewired, 8 ft (2.4 m) each UP 15-42 BUC7/MR • One prewired 6-ft line cord • one outdoor air-temperature sensor • Optional zone control input TM03 8756 2407 TM03 8755 2407 • Optional boiler on/off output. Dimensions [inches] Model type Product number A B C D E F Connection type and size Shipping weight [lbs] UP 15-42 BUC5/MR 59896805 6 1/2 5 1/4 4 3 3/16 3 1/4 - 1/2" sweat 6 1/2 UP 15-42 BUC7/MR 59896806 7 3/4 5 1/4 4 3 3/4 3 1/4 - 3/4" sweat 6 3/4 Note: Dimensions in inches unless otherwise noted. 41 Technical data UP 15-42 F/FR H [ft] 16 14 Flow range: 0-17 gpm Head range: 0-15 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 10 Closed system 8 Model 6 Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V 230 0.43 95 1/25 2μF/400 V UP 15-42 F/FR 4 Approvals 0 0 2 4 6 8 10 12 14 16 18 Q [GPM] TM03 8527 1907 UP 15-42 FR TM03 8526 1907 UP 15-42 F TM03 5533 0709 2 Product number Dimensions [inches] Model type UP 15-42 F 115 V 230 V 59896155 59896173 A B 5 1/4 6 1/2 UP 15-42 FR 59896167 59896274 Note: Dimensions in inches unless otherwise noted. 42 C D F 3 1/4 3 5/32 4 3/16 4 5 15/16 E 3 3/4 Connection type and size Shipping weight [lbs] GF 15/26 flange (2) 1/2" dia. bolt holes 7 1/4 Technical data UPS 15-42 F H [ft] 16 3 14 2 12 Flow range: 0-17.5 gpm Head range: 0-15.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 10 Model Spd Volts Amps Watts 0.41 92 0.19 40 0.14 30 Hp Capacitor 1/25 2μF/400 V 8 3 1 6 UPS 15-42 F 2 1 4 0 0 2 4 6 8 10 12 14 16 18 Q [GPM] TM03 5574 0907 2 230 Approvals TM03 8757 2407 UPS 15-42 F Product number Dimensions [inches] Model type UPS 15-42 F 115 V 230 V A B C D E F - 59896180 6 1/2 5 1/4 4 4 3/16 3 1/4 3 5/32 Connection type and size Shipping weight [lbs] GF 15/26 flange (2) 1/2" dia. bolt holes 7 1/4 Note: Dimensions in inches unless otherwise noted. 43 Technical data UP 15-42 FC/MR UP 15 MixiMizer H [ft] a. MIN b. MAX 16 b 14 Flow range: 0-16 gpm Head range: 0-15 feet Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 Model Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V 10 UP 15-42 FC/MR 8 Approvals 6 2 a 0 0 2 4 6 8 10 12 14 16 18 Q [GPM] TM03 8838 2607 4 MixiMizer models include the following features: • Two water-temperature sensors (system supply and return (prewired, 8 ft (2.4 m) each • One prewired 6-ft line cord UP 15-42 FC/MR • one outdoor air-temperature sensor • Optional zone control input TM03 8528 1907 • Optional boiler on/off output. Dimensions [inches] Model type UP 15-42 FC/MR Product number 59896804 Note: Dimensions in inches unless otherwise noted. 44 A B C D E F 6 1/2 5 1/4 4 4 3/16 3 1/4 3 5/32 Connection type and size Shipping weight [lbs] GF 15/26 flange (2) 1/2" dia. bolt holes 7 1/2 Technical data UP 15-42 F/VS UP 15 Variable Speed H [ft] a. MIN b. MAX 16 b 14 Flow range: 0-16 gpm Head range: 0-15.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 205 °F (96 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 Model Volts Amps Watts Hp Capacitor 115 0.74 85 1/25 10μF/180 V 10 UP 15-42 F/FV 8 Approvals 6 2 a 0 0 2 4 6 8 10 12 14 16 18 Q [GPM] TM03 8840 0907 4 UP 15-42 F/VS Variable speed models include the following features: • Three speed control options: 1) Manual 2) Voltage: 0-10V(DC) or 2-10V(DC) 3) Current: 0-20mA or 4-20 mA • Dip switch control selection • Pump exercising • Manual offset dial TM03 8528 1907 • Performance indicator LED's. Dimensions [inches] Model type UP 15-42 F/VS Product number 59896807 A B C D E F 6 1/2 5 1/4 4 4 3/16 3 1/4 3 5/32 Connection type and size Shipping weight [lbs] GF 15/26 flange (2) 1/2" dia. bolt holes 7 1/2 Note: Dimensions in inches unless otherwise noted. 45 Technical data UP 15-55 SUC H [ft] Flow range: 0-21.5 gpm Head range: 0-17 feet 18 Motors: 2-pole, single-phase 16 Max. liquid temperature: 230 °F (110 °C) 14 Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 12 Closed system 10 Model 8 UP 15-55 SUC 6 Volts Amps Watts Hp Capacitor 230 0.42 97 0.13 2μF/400 V Approvals 4 0 0 2 4 6 8 10 12 14 16 18 20 22 Q [GPM] TM03 8845 2607 2 TM03 8777 2507 UP 15-55 SUC Product number Dimensions [inches] Model type UP 15-55 SUC 115 V 230 V A B C D E F - 59896786 5 7/8 5 1/16 4 1/8 3 7/16 2 15/16 - Note: Dimensions in inches unless otherwise noted. 46 Connection type and size Shipping weight [lbs] GU125 5.4 Technical data UPS 15-55 SFC/SUC H [ft] 18 3 16 2 14 Flow range: 0-25 gpm Head range: 0-18 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Note: If the UP pump is equipped with a timer, the maximum liquid temperature is 150 °F (66 °C). 12 10 1 Model Spd Volts 3 8 UPS 15-55 SFC 115 2 Amps Watts Hp 0.75 87 0.12 0.69 77 0.1 1 0.53 58 0.08 3 0.69 87 0.12 0.66 74 0.1 0.31 56 0.08 Capacitor 6 10μF/180 V 4 0 0 2 4 6 8 10 12 14 16 18 20 22 24 2 Q [GPM] TM03 8849 2607 UPS 15-55 SUC 2 2 115 1 Without check valve With check valve Approvals TM03 8778 2507 UPS 15-55 SUC/TLC TM03 8779 2507 UPS 15-55 SFC Dimensions [inches] Model type Product number A B C D E F Connection type and size Shipping weight [lbs] UPS 15-55 SFC 59896773 6 1/2 5 1/2 4 1/8 3 7/8 2 15/16 3 1/8 GF15/26 6 UPS 15-55 SUC 59896781 5 7/8 5 1/16 4 1/8 3 7/16 2 15/16 - GU125 5.4 UPS 15-55 SUC/TLC 59896783 5 7/8 5 1/16 4 1/8 3 7/16 2 15/16 - GU125 6.2 Note: LC/TLC Models have 6 ft (1.8 m), 3-prong power cord. Removable check valve. Dimensions in inches unless o herwise noted. 47 Technical data ALPHA 15-55 F/FR/SF/LC UP 15 ALPHA TM04 6025 0611 Performance* and operation mode selection Pos. Description Pos. Description • Push-button for selection of pump setting • Every time the push-button is pressed, the circulator setting is changed Constant Pressure I • The duty point of the pump will move left and right along the lowest constant-pressure curve depending on water demand in the system. The pump head (pressure) is kept constant, irrespective of the water demand. III High Fixed Speed • Runs at a constant speed and consequently on a constant curve. In Speed III, the pump is set on the maximum curve under all operating conditions. Quick Vent of the pump can be obtained by setting the pump to Speed III for a short period. Constant Pressure II • The duty point of the pump will move left and right along the middle constant-pressure curve depending on water demand in the system. The pump head (pressure) is kept constant, irrespective of the water demand. II Medium Fixed Speed • Runs at a constant speed and consequently on a constant curve. In Speed II, the pump is set on the medium curve under all operating conditions. Constant Pressure III • The duty point of the pump will move left and right along the highest constant-pressure curve depending on water demand in the system. The pump head (pressure) is kept constant, irrespective of the water demand. I Low Fixed Speed • Runs at a constant speed and consequently on a constant curve. In Speed I, the pump is set on the minimum curve under all operating conditions. AutoAdapt (Factory Setting) • This function controls the pump performance automatically within the defined performance range. Automatically adjusting the pump performance to system demands over time. *Hydraulic performance without check valve. ALPHA 15-55 F Terminal box ALPHA 15-55 FR Terminal box B B C F C 48 D TM04 9774 0111 E TM04 9773 0111 D E G G A A F Technical data ALPHA 15-55 F/FR/SF/LC UP 15 ALPHA Flow range: 0-21.5 gpm Head range: 0-17 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 150 psi (10 bar) Closed (F, FR) and Open systems (SF) ALPHA 15-55 F Linecord F B E G A C Model ALPHA 15-55 Volts Amps Watts Hp Capacitor 115 0.65 5 to 45 0.06 - D TM04 6012 4709 Approximate power usage Speed setting ALPHA 15-55 FR Linecord B Min. Max. High fixed speed III 39W 45W Medium fixed speed II 15W 30W Low fixed speed I 5W 8W Constant pressure 8W 45W Constant pressure 14W 45W Constant pressure 22W 45W AutoADAPT 5W 45W F E G A C Approvals Canadian EMC Standard ICES-003 This Class B digital apparatus complies with Canadian ICES-003. TM04 6013 4709 D Dimensions [inches] Model type ALPHA 15-55 F Product number 59896877 A B C 6 1/2 6 1/2 5 1/4 D E 3 13/16 3 11/16 F G 3 9/16 5 3/8 ALPHA 15-55 FR 59896878 6 1/2 7 3/16 5 1/4 3 13/16 3 11/16 3 9/16 5 3/8 ALPHA 15-55 SF 59896879 6 1/2 6 1/2 5 1/4 3 13/16 3 11/16 3 9/16 5 3/8 ALPHA 15-55 F/LC 59896832 6 1/2 6 1/2 4 15/16 3 7/16 4 1/8 4 2 1/2 ALPHA 15-55 FR/LC 59896833 6 1/2 7 4 15/16 4 2 1/2 3 7/16 4 1/8 ALPHA 15-55 SF/LC 59896834 6 1/2 6 1/2 4 15/16 4 2 1/2 3 7/16 4 1/8 Connection type and size Shipping weight [lbs] 7.20 GF 15/26 (2) 1/2” dia. bolt holes 7.10 6.10 7.50 GF 15/26 (2) 1/2” dia. bolt holes 7.33 6.25 Note: Dimensions in inches unless otherwise noted. 49 Technical data UPS 15-58 FC/FRC H [ft] 20 3 18 2 16 14 1 12 10 Flow range: 0-17 gpm Head range: 0-19.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Model Spd 8 3 6 UPS 15-58 FC/FRC 4 2 0 0 2 4 6 8 10 12 14 16 18 20 Q [GPM] Watts Hp Capacitor 0.75 87 1/25 0.66 80 1/25 10μF/180 V 0.55 60 1/25 With check valve Approvals TM03 8531 1907 Dimensions [inches] Model type 115 Amps Without check valve UPS 15-58 FRC TM03 8757 2407 UPS 15-58 FC TM03 5535 0907 1 2 Product number A B C D E F Connection type and size Shipping weight [lbs] UPS 15-58 FC 59896341 6 1/2 5 1/4 4 4 3/16 3 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 7 1/4 UPS 15-58 FRC 59896343 6 1/2 5 1/4 4 4 3/16 3 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 7 1/4 Note: The check valve can be removed. Dimensions in inches unless o herwise noted. 50 Volts Technical data UP 15-100 F Flow range: 0-8.4 gpm Head range: 0-36 feet 36 Motors: 2-pole, single-phase 32 Max. liquid temperature: 205 °F (96 °C) 28 Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) H [ft] 24 Closed system 20 Model 16 UP 15-100 F 12 8 Volts Amps Watts Hp Capacitor 115 1.1 135 1/25 12μF/180 V 0 0 1 2 3 4 5 6 7 8 9 Q [GPM] TM03 5534 3806 Approvals 4 TM03 8530 1907 UP 15-100 F Dimensions [inches] Model type UP 15-100 F Product number 59896300 A B C D E F 6 1/2 5 1/4 4 4 3/16 3 1/4 3 5/32 Connection type and size Shipping weight [lbs] GF 15/26 flange (2) 1/2" dia. bolt holes 7 1/4 Note: Dimensions in inches unless otherwise noted. 51 Technical data UP 26-64 F Flow range: 0-32 gpm Head range: 0-24.5 feet Motors: 2-pole, single-phase 22 Max. liquid temperature: 230 °F (110 °C) 20 Min. liquid temperature: 36 °F (2 °C) 18 Max. system pressure: 145 psi (10 bar) 16 Closed system H [ft] 26 24 14 12 Model Volts Amps Watts Hp Capacitor 115 1.7 185 1/12 8μF/180 V 230 0.8 175 1/12 2.5μF/380 V 10 8 UP 26-64 F 6 2 0 0 4 8 12 16 20 24 28 32 36 Q [GPM] TM03 5536 0907 4 Approvals TM03 8776 2507 UP 26-64 F Product number Dimensions [inches] Model type UP 26-64 F 115 V 230 V A B C D E F 52722330 52722327 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 3 5/32 Note: Dimensions in inches unless otherwise noted. 52 Connection type and size Shipping weight [lbs] GF 15/26 flange (2) 1/2" dia. bolt holes 11 1/4 Technical data UP 26-64 F/VS UP 26 Variable Speed H [ft] a. MIN b. MAX b 24 20 16 Flow range: 0-34 gpm Head range: 0-24.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 195 °F (91 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Model 12 UP 26-64 F/VS Volts Amps Watts Hp Capacitor 115 1.7 185 1/12 8μF/180 V 8 Approvals 4 0 0 4 8 12 16 20 24 28 32 36 40 Q [GPM] TM03 8841 2607 a UP 26-64 F/VS Variable speed models include the following features: • Three speed control options: 1) Manual 2) Voltage: 0-10V(DC) or 2-10V(DC) 3) Current: 0-20mA or 4-20 mA • Dip switch control selection • Pump exercising • Manual offset dial TM03 8533 1907 • Performance indicator LED's. Dimensions [inches] Model type UP 26-64 F/VS Product number 52722553 A B C D E F 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 3 5/32 Connection type and size Shipping weight [lbs] GF 15/26 flange (2) 1/2" dia. bolt holes 11 1/4 Note: Dimensions in inches unless otherwise noted. 53 Technical data UP 26-96 F/BF Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) 26 Max. system pressure: 145 psi (10 bar) 24 Closed system (F) and open system (BF) H [ft] 30 28 22 20 Model Volts Amps Watts Hp Capacitor 115 1.7 205 1/12 10μF/180 V 230 0.8 205 1/12 2.5μF/380 V 18 16 UP 26-96 F/BF 14 12 Approvals 10 8 UP 26-96 F/BF UP 26-96 BF 4 2 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30 Q [GPM] Flow range: 0-28 gpm Head range: 0-30 feet TM03 8543 1907 UP 26-96 BF TM03 8533 1907 UP 26-96 F TM03 5556 0907 6 Product number Dimensions [inches] Connection type and size Shipping weight [lbs] 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 11 1/4 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 12.5 Model type 115 V 230 V A B C D E F UP 26-96 F 52722341 52722338 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 UP 26-96 BF 52722336 52722334 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 Note: Dimensions in inches unless otherwise noted. 54 Technical data UP 26-96 F/VS UP 26 Variable Speed H [ft] a. MIN b. MAX 32 b 28 Flow range: 0-28 gpm Head range: 0-30 feet Motors: 2-pole, single-phase Max. liquid temperature: 195 °F (91 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 24 20 Model 16 UP 26-96 F/VS Volts Amps Watts Hp Capacitor 115 1.7 205 1/12 10μF/180 V 12 Approvals 8 4 0 0 4 8 12 16 20 24 28 32 36 Q [GPM] TM03 8842 2607 a UP 26-96 F/VS Variable speed models include the following features: • Three speed control options: 1) Manual 2) Voltage: 0-10V(DC) or 2-10V(DC) 3) Current: 0-20mA or 4-20 mA ] • Dip switch control selection • Pump exercising • Manual offset dial TM03 8533 1907 • Performance indicator LED's. Product number Dimensions [inches] Model type UP 26-96 F/VS 115 V 230 V A B C D E F 52722552 - 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 3 5/32 Connection type and size Shipping weight [lbs] GF 15/26 flange (2) 1/2" dia. bolt holes 11 1/4 Note: Dimensions in inches unless otherwise noted. 55 Technical data UP 26-99 F/BF Flow range: 0-34 gpm Head range: 0-32 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Closed system (F) and Open system (BF) H [ft] 32 28 24 20 Model 16 Volts Amps Watts Hp Capacitor 115 2.15 245 1/6 10μF/180 V 230 1.07 245 1/6 2.5μF/380 V UP 26-99 F/BF 12 Approvals 8 UP 26-99 F/BF 0 0 4 8 12 16 20 24 28 32 36 Q [GPM] UP 26-99 BF TM03 5557 0907 4 TM03 8532 1907 UP 26-99 F/BF Product number Dimensions [inches] Connection type and size Shipping weight [lbs] 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 12 1/2 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 12 1/2 Model type 115 V 230 V A B C D E F UP 26-99 F 52722355 52722351 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 UP 26-99 BF 52722347 52722346 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 Note: Dimensions in inches unless otherwise noted. 56 Technical data UPS 26-99 F/BFC H [ft] Flow range: 0-33 gpm Head range: 0-29 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) 3 28 2 24 1 20 16 Model Spd Volts Amps Watts Hp Capacitor 1.8 197 1/6 20μF/180 V 1.5 179 1/6 20μF/180 V 1 1.3 150 1/6 20μF/180 V 3 0.9 196 1/6 5μF/400 V 0.8 179 1/6 5μF/400 V 0.7 150 1/6 5μF/400 V 12 3 8 UPS 26-99 FC 2 0 0 4 8 12 16 20 24 28 32 36 Q [GPM] TM03 8195 2006 4 UPS 26-99 FC/BFC 2 115 230 1 Without check valve UPS 26-99 FC UPS 26-99 BFC With check valve Approvals UP 26-99 BFC TM03 8531 1907 TM03 8757 2407 UP 26-99 F/BFC Product number Dimensions [inches] Connection type and size Shipping weight [lbs] 3 7/16 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 10.3 3 7/16 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 10.3 Model type 115 V 230 V A B C D UPS 26-99 FC 52722512 52722513 6 1/2 6 4 7/8 3 1/2 UPS 26-99 BFC 52722518 52722519 6 1/2 6 4 7/8 3 1/2 E F Note: The check valve can be removed. Dimensions in inches unless o herwise noted. 57 Technical data UP 26-116 F/BF H [ft] 40 Flow range: 0-37 gpm Head range: 0-37 feet Motors: 2-pole, single-phase 36 Max. liquid temperature: 150 °F (65 °C) 32 Min. liquid temperature: 32 °F (0 °C) 28 Max. system pressure: 145 psi (10 bar) 24 Closed system (F) and Open system (BF) 20 Model 16 UP 26-116 F/BF 12 Amps Watts Hp Capacitor 230 1.8 385 1/6 2.5μF/380 V Approvals 4 0 0 4 8 12 16 20 24 28 32 36 40 Q [GPM] UP 26-116 F/BF TM03 8543 1907 Dimensions [inches] Model type UP 26-116 BF UP 26-116 BF TM03 8758 2407 UP 26-116 F TM03 5577 0907 8 Product number A B C D E F Connection type and size Shipping weight [lbs] UP 26-116 F 52722377 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 12 1/2 lbs UP 26-116 BF 52722393 6 1/2 6 3/8 5 1/16 4 1/8 3 1/2 3 5/32 GF 15/26 flange (2) 1/2" dia. bolt holes 12 1/2 lbs Note: Dimensions in inches unless otherwise noted. 58 Volts Technical data UP 26-120 U H [ft] 40 36 Flow range: 0-19 gpm Head range: 0-38 feet Motors: 2-pole, single-phase Max. liquid temperature: 203 °F (95 °C) 32 Min. liquid temperature: 32 °F (0 °C) 28 Max. system pressure: 145 psi (10 bar) 24 Closed system 20 16 Model 12 Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.5μF/380 V UP 26-120 U 8 TM03 5546 3806 4 0 0 2 4 6 8 10 12 14 16 18 20 Q [GPM] Approvals TM03 8761 2407 UP 26-120 U Product number Dimensions [inches] Model type UP 26-120 U 115 V 230 V A B C D E 52722435 52722436 7 1/16 5 7/8 5 1/16 4 7/8 3 1/2 Connection type and size Shipping weight [lbs] GF 125 union - 1 1/4" NPSM 10 1/2 Note: Dimensions in inches unless otherwise noted. 59 Technical data UPS 26-150 F/SF 3 2 1 Flow range: 0-53 gpm Head range: 0-46 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Model Spd Volts Amps Watts Hp 3.5 370 1/6 3.1 335 1/6 1 2.5 265 1/6 3 1.7 350 1/6 1.5 310 1/6 1 1.2 250 1/6 3 1.7 370 1/6 1.5 335 1/6 1.2 265 1/6 TM04 5463 3 2 UPS 26-150 F/SF UPS 26-150 F/SF B 2 115 208 Capacitor 40μF/ 180V 10μF/ 400V C 2 A 1 230 10μF/ 400V D F TM04 6014 E Approvals Product number Dimensions [inches] Connection type and size Shipping weight [lbs] 3 1/8 GF 15/26 flange (2) 1/2" dia. bolt holes 17.35 3 1/8 GF 15/26 flange (2) 1/2" dia. bolt holes 17.35 Model type 115 V 208 / 230 V A B C D E F UPS 26-150 F 95906630 95906631 6 1/2 7 1/8 5 7/8 3 7/8 3 3/4 UPS 26-150 SF 95906632 95906633 6 1/2 7 1/8 5 7/8 3 7/8 3 3/4 Note: Dimensions in inches unless otherwise noted. 60 Technical data UP 43-44 F/BF Flow range: 0-68 gpm Head range: 0-13.5 feet 13 Motors: 2-pole, single-phase 12 Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 32 °F (0 °C) 9 Max. system pressure: 145 psi (10 bar) 8 Closed system (F) and open system (BF) H [ft] 14 11 10 7 6 Model 5 Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.5μF/380 V UP 43-44 F/BF 4 3 2 TM03 5558 3806 1 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [GPM] Approvals TM03 8544 1907 UP 43-44 F/BF Product number Dimensions [inches] Connection type and size Shipping weight [lbs] 3 7/16 GF 40/43 flange (2) 1/2" dia. bolt holes 13 1/2 3 7/16 GF 40/43 flange (2) 1/2" dia. bolt holes 15 Model type 115 V 230 V A B C D E F UP 43-44 F 52722437 52722438 8 1/2 6 11/16 5 3/16 4 3/4 3 1/2 UP 43-44 BF 52722439 52722440 8 1/2 6 11/16 5 3/16 4 3/4 3 1/2 Note: Dimensions in inches unless otherwise noted. 61 Technical data UPS 43-44 FC/BFC H [ft] 14 Flow range: 0-63 gpm Head range: 0-14 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 32 °F (0 °C) Max. system pressure: 145 psi (10 bar) 3 2 12 10 1 8 Model Spd Volts Amps Watts Hp Capacitor 1.8 203 1/6 20μF/180 V 1.7 189 1/6 20μF/180 V 1 1.4 157 1/6 20μF/180 V 3 0.9 203 1/6 5μF/400 V 0.8 190 1/6 5μF/400 V 0.7 157 1/6 5μF/400 V 3 6 UPS 43-44 FC/BFC 4 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 Q [GPM] TM03 8196 0807 2 UPS 43-44 FC/BFC 2 2 1 115 230 Without check valve With check valve UPS 43-44 FC/BFC TM03 8757 2407 Approvals Product number Dimensions [inches] Connection type and size Shipping weight [lbs] 3 7/16 GF 40/43 flange (2) 1/2" dia. bolt boles 13 1/2 3 7/16 GF 40/43 flange (2) 1/2" dia. bolt boles 13 1/2 Model type 115 V 230 V A B C D E F UPS 43-44 FC 52722514 52722515 8 1/2 6 11/16 5 1/8 4 3/4 3 3/16 UPS 43-44 BFC 52722520 52722521 8 1/2 6 11/16 5 1/8 4 3/4 3 3/16 Note: The check valve can be removed. Dimensions in inches unless o herwise noted. 62 Technical data UP 43-70 F H [ft] 25 20 Flow range: 85 gpm Head range: 24.5 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 14 °F (-10 °C) Max. system pressure: 145 psi (10 bar) Closed system 15 Model 10 Volts Amps Watts Hp Capacitor 115 3.4 400 1/2 30μF 230 1.8 400 1/2 30μF UP 43-70 F TM04 9904 0211 5 0 0 10 20 30 40 50 60 70 80 90 Q [US GPM] UP 43-70 F B7 M D5 B5 H3 B1 B 2 H1 H2 TM02 0210 0211 B4 D1 D2 D3 D7 D6 L3 L1 D4 NPT 1/4 Product number Model type Connection type and size Shipping weight [lbs] GF 40/30 flange 1 1/2" 2 bolt with (2) 1/2" dia. holes holes 41 115 / 230 V UP 43-70 F 96439644 Dimensions [inches] L1 L3 B1 B2 8 1/2 4 1/4 5 5/16 5 9/16 B4 B5 2 15/16 2 15/16 B7 H1 H2 H3 D1 D2 D3 D4 D6 D7 3 1/8 2 5/8 9 5/8 12 3/16 1 5/8 2 5/16 3 7/16 4 3/4 2 2 1/2 Note: Dimensions in inches unless otherwise noted. 63 Technical data UP 43-75 F/BF Flow range: 0-41 gpm Head range: 0-25 feet 24 Motors: 2-pole, single-phase 22 Max. liquid temperature: 230 °F (110 °C) 20 Min. liquid temperature: 36 °F (2 °C) 18 Max. system pressure: 145 psi (10 bar) H [ft] 26 16 Open system 14 12 Model Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.5μF/380 V 10 8 UP 43-75 F/BF 6 4 0 0 4 8 12 16 20 24 28 32 36 40 44 Q [GPM] TM03 5560 0907 Approvals 2 TM03 8544 1907 UP 43-75 F/BF Product number Dimensions [inches] Connection type and size Shipping weight [lbs] 3 7/16 GF 40/43 flange (2) 1/2" dia. bolt holes 13 1/2 3 7/16 GF 40/43 flange (2) 1/2" dia. bolt holes 15 Model type 115 V 230 V A B C D E F UP 43-75 F 52722373 52722372 8 1/2 6 11/16 5 3/16 4 3/4 3 1/2 UP 43-75 BF 52722370 52722369 8 1/2 6 11/16 5 3/16 4 3/4 3 1/2 Note: Dimensions in inches unless otherwise noted. 64 Technical data UPS 43-100 F/SF Flow range: 0-65 gpm Head range: 0-31 feet 3 2 Motors: 2-pole, single-phase 1 Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (2 °C) Max. system pressure: 145 psi (10 bar) Model Spd Volts Amps Watts Hp Capacitor 3.5 370 1/6 40μF/180 V 3.1 335 1/6 40μF/180 V 1 2.5 265 1/6 40μF/180 V 3 1.7 350 1/6 10μF/400 V 1.5 310 1/6 10μF/400 V 1 1.2 250 1/6 10μF/400 V 3 1.7 370 1/6 10μF/400 V 1.5 335 1/6 10μF/400 V 1.2 265 1/6 10μF/400 V 3 TM04 5464 2 UPS 43-100 F/SF UPS 43-100 F/SF B C 2 2 1 115 208 230 D F TM04 6015 E A Approvals Product number Dimensions [inches] Model type UPS 43-100 F UPS 43-100 SF 115 V 208 - 230 V 95906636 95906637 95906638 A B C D E F 8 1/2 7 3/8 5 7/8 4 1/2 3 3/4 3 1/8 95906639 Connection type and size Shipping weight [lbs] GF 40/43 flange (2) 1/2" dia. bolt boles 18.47 GF 40/43 flange (2) 1/2" dia. bolt boles 18.47 Note: Dimensions in inches unless otherwise noted. 65 Technical data UP 43-110 F H [ft] 40 Flow range: 0-98 gpm Head range: 0-37 feet Motors: 2-pole, single-phase 36 Max. liquid temperature: 230 °F (110 °C) 32 Min. liquid temperature: 14 °F (–10 °C) 28 Max. system pressure: 145 psi (10 bar) 24 Closed system 20 Model Volts Amps Watts Hp Capacitor 115 5.1 590 3/4 60μF 230 2.7 590 3/4 60μF 16 UP 43-110 F 12 8 Approvals TM03 5951 3806 4 0 0 10 20 30 40 50 60 70 80 90 100 Q [GPM] UP 43-110 F B7 D1 D2 D3 D7 D6 L3 L1 D4 M D5 B5 H3 B1 B 2 H1 H2 TM02 0120 4301 B4 NPT 1/4 Product number Model type 115 V / 230 V UP 43-110 F Connection type and size Shipping weight [lbs] GF 40/43 Flange 1 1/2” 41.2 96439643 Dimensions [inches] L1 L3 B1 8 1/2 4 1/4 5 1/4 B2 B4 5 9/16 2 15/16 2 15/16 Dimensions in inches unless o herwise noted. 66 B5 B7 H1 H2 H3 D1 3 1/8 2 5/8 9 5/8 12 3/16 1 5/8 D2 D3 2 15/16 3 7/16 D4 D6 D7 M 4 3/4 2 1/16 2 1/2 12 mm Technical data H [ft] UPS 50-44 F 3 2 14 13 12 11 1 10 9 Flow range: 0-65 gpm Head range: 0-14.4 feet Motors: 2-pole, single-phase Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 32 °F (0 °C) Max. system pressure: 145 psi (10 bar) 8 7 Model Spd Volts Amps Watts Hp 1.7 194 1/6 1.6 181 1/6 1 1.3 147 1/6 3 0.87 195 1/6 0.81 182 1/6 0.74 147 1/6 Capacitor 6 3 5 2 4 3 115 20μF UPS 50-44 F 2 0 0 5 10 15 20 25 30 35 40 45 50 55 60 65 70 Q [GPM] TM03 8837 2607 1 2 1 230 5μF Approvals TM04 54713209 UPS 50-44 F Product number Dimensions [inches] Model type UPS 50-44 F 115 V 230 V A B C D E F 52722557 52722558 8 1/2 7 1/2 5 1/16 4 7/8 3 1/2 4 1/6 Connection type and size Shipping weight [lbs] GF 50 flange (4) 1/2" dia. bolt holes 15 1/2 Note: Dimensions in inches unless otherwise noted. 67 Technical data UPS 50-60 F/SF Flow range: 120 gpm Head range: 21 feet 3 Motors: 2-pole, single-phase 2 Max. liquid temperature: 230 °F (110 °C) Min. liquid temperature: 36 °F (10 °C) Max. system pressure: 145 psi (10 bar) Closed or Open system 1 Model Spd Volts Amps Watts Hp 3.6 395 1/6 3.4 350 1/6 1 2.7 260 1/6 3 1.9 395 1/6 1.7 350 1/6 1 1.4 290 1/6 3 1.8 395 1/6 1.7 350 1/6 1.4 260 1/6 3 TM04 7918 2410 2 UPS 50-60 F/SF 2 115 208 Capacitor 40μF/180V 10μF/400V 2 UPS 50-60 F/SF 1 230 B C TM04 9775 0111 F D E A Approvals Product number Dimensions [inches] Model type 115 V 208 - 230 V UPS 50-60 F 97523134 — UPS 50-60 F — 97523135 A C D E F Connection type and size Shipping weight [lbs] 20 20 8 1/2 8 5/8 6 1/4 4 3/4 3 3/4 2 7/8 GF 50 UPS 50-60 SF 97523136 — 19.5 UPS 50-60 SF — 97523137 19.5 Note: Dimensions in inches unless otherwise noted. 68 B Technical data UP 50-75 F Flow range: 0-41 gpm Head range: 0-25 feet Motors: 2-pole, single-phase 22 Max. liquid temperature: 230 °F (110 °C) 20 Min. liquid temperature: 32 °F (0 °C) 18 Max. system pressure: 145 psi (10 bar) H [ft] 26 24 16 Closed system 14 12 Model Volts Amps Watts Hp Capacitor 115 2.15 215 1/6 10μF/180 V 230 1.07 220 1/6 2.5μF/400 V 10 UP 50-75 F 8 4 2 0 0 4 8 12 16 20 24 28 32 36 40 44 Q [GPM] TM03 5545 0907 6 Approvals TM03 8760 2407 UP 50-75 F Product number Dimensions [inches] Model type UP 50-75 F 115 V 230 V A B C D E F 52722352 52722353 8 1/2 7 1/2 5 1/16 4 7/8 3 1/2 4 1/6 Connection type and size Shipping weight [lbs] GF 50 flange (4) 1/2" dia. bolt holes 15 1/2 Note: Dimensions in inches unless otherwise noted. 69 Accessories UP Series This page intentionally left blank. 70 Accessories UP Series UP timer Specifications (previous/current) Type: 24 Hr. 3-position On/Timer/Off 15-minute interval • Size: 3.77 x 2.85 x 1.25" • Supply voltage: 120 VAC • Power consumption: 1 VA Switch rating: SPDT • Resistive: 21A/6 A • Tungsten: 1350 W. TM03 4406 3507 • Inductive: 1 HP @ 120 VAC; 2 HP @ 240 VAC Wiring connections: 1/4" quick-connects. Installation Indoor, wired and mounted on the UP terminal box. Fig. 2 Timer dimensions, previous version Features • Compact and contemporary design. • Captive trippers are easy to set, cannot be lost. • Quartz drive provides 7-day carry-over. Previous timer Date codes 9132-0527 TM03 9076 3307 TM03 7893 0307 • Synchronous drive for greatest accuracy, lowest cost Current timer Date codes 0528 and after Fig. 3 Timer dimensions, current version Fig. 1 UP timers Timer control Shipping weight Length Height Width Product number Description [oz.] [mm] [inch] [mm] [inch] 505474 24-hour programmable clock/timer for use with single speed. Series UP (115 V) circulator* for date codes 9132 - 0527 10 62 2 7/16 32 1 17/64 60 2 3/8 599388 24-hour programmable clock/timer for use with single speed. Series UP (115 Vt) circulator* for UP 15 only date code 0528 and after 10 62 2 7/16 32 1 17/64 60 2 3/8 [mm] [inch] Approvals ® 71 Accessories UP Series AquaStat Specifications 1.082 DIA. Description: Thermostatic switch. ±0.045 0.50 Type: Bi-metallic disc, snap acting. Enclosure: environmentally sealed. Mounting: ±0.250 2.0 • Clip-on mount for 1/2” I.D. copper tube (5/8" O.D.). • Clip-on mount for 3/4” I.D. copper tube (7/8" O.D.). Contact rating: ±0.37 14.0 • 10 A @ 120 VAC, 60 Hz resistive. • 5 A @ 240 VAC, 60 Hz resistive. Temperature rating Low-temp model • 105+5 °F (40+2 °C) pump switches off. • 85+6 °F (29+3 °C) pump switches on. TM03 4408 2006 1 31 High-temp model • 115+5 °F (46+2 °C) pump switches off. • 105+5 °F (40+2 °C) pump switches on. 1.02 Leads: DIA. • 2 leads, AWG 18, 14". Fig. 4 AquaStat dimensions • 12", black insulation, silicon or epoxy overmold. • 1/2" strip length. Application: TM03 4407 2006 • Clip-on thermostatic control for the UP circulators. Approvals ® Fig. 5 AquaStat Thermostatic controls Product Description number 595443 Aquastat set, 1/2" clip-on mount for 5/8" O.D. system piping size, 85 °F - 105 °F* (1/2" I.D. copper tubing or 3/8" steel pipe) shielded wire, with PVC jacketed cable 1 lb 595444 Aquastat set, 3/4" clip-on mount for 7/8" O.D. system piping size, 85 °F - 105 °F* (3/4" I.D. copper tubing or 1/2" steel pipe) shielded wire, with PVC jacketed cable 1 lb 595656 Aquastat set, 1/2" clip-on mount for 5/8" O.D. system piping size, 105 °F - 115 °F* (1/2" I.D. copper tubing or 3/8" steel pipe) shielded wire, with PVC jacketed cable 1 lb 595657 Aquastat set, 3/4" clip-on mount for 7/8" O.D. system piping size, 105 °F - 115 °F* (3/4" I.D. copper tubing or 1/2" steel pipe) shielded wire, with PVC jacketed cable 1 lb Note: Dimensions in inches unless otherwise noted. 72 Shipping weight [oz.] Accessories UP Series Pump Zone Controls Approvals Specifications Grundfos Zone Controls are non-networked devices intended to be used for circulator and boiler control in hydronic heating systems. • One, three, and four - expandable to six zones • Powder coated panel surface TM04 9906 0311 - TM04 9907 0311 • Multi-panel linking capability • Selectable priority and freeze protection • Single service relay for all models • 2-wire with one 3-wire thermostat capability • Automatic reset PTC fuse on system 24 VAC • High capacity 25VA rated transformer • Multiple knockouts • Separate X-X & ZC-ZR terminals for “Cold Start” or “Tankless Coil” boilers Fig. 1 Grundfos Zone Controls • Models UPZC-3 & UPZC-4/6 only: (with closeup of circuit board) - No priority - Zone 1 priority W Dimensions [in] L W D UPZC-1 5.2 4.3 2.9 UPZC-3, 4/6 9.8 12.1 2.9 L D Model TM04 9908 0311 - Zone 1 priority w/ 1-hour freeze protection Note: Dimensions in inches unless otherwise noted. Model UPZC-1 UPZC-3 UPZC-4/6 96741787 96741788 96741789 1 3 4 to 6 Priority feature No Yes Yes Priority timer (min.) N/A 60 60 Part number Number of zones Input power 60 hz 120VAC +/- 10% Transformer voltage 120VAC, 24V, 15VA, Class 2 Thermostat output (amps) 0.13A Max. single phase motor rating (per zone) Max. combined load rating: Output @ 120VAC (amps) 1/3Hp, 10A, GP 10A Min./max. ambient temperature range 32 °F (0 °C) / 104 °F (40 °C) Max. operating humidity range: % RH Number of knockouts 0.95 4 Size of knockouts (in.) UPZC dimensions: W x H x D (in.) 30A 14 7/8-inch 5-3/16 x 4-5/15 x 2-15/16 15 x 11-3/8 x 4-7/8 Relay type DPDT Socketed Approvals UL-873, CAN/CSA C22.2 No. 24 Universal service relay Part number: 10 ea. 96741790 73 Accessories UP Series Packaged dielectric isolation valve sets D B C TM04 9909 0311 F E Pump connection Pipe connection type and size NPT Bronze Material Approx. shipping number weight Solder 1/2" GF 15/26 flange TM03 7901 0307 A 96806129 Face to face [A*] Center of port to top [B*] Flange diameter [C*] [lb/oz.] 1 kit [inch] [mm / inch] [inch] [inch] 2 / 13 2 27/32 51 / 2 4 3/16 3 29/64 3/4" 96806130 3/2 3 3/64 57 / 2 1/4 4 3/16 3 3/4 1" 96806131 4/8 3 35/64 67 / 2 21/32 4 3/16 4 17/32 1-1/4" 96806132 4 / 13 4 1/32 75 / 2 31/32 4 3/16 4 35/64 1-1/2" 96806133 4 / 14 4 7/64 75 / 2 31/32 4 3/16 4 5/8 96806134 2 / 12 2 49/64 51 / 2 4 3/16 3 15/32 3 47/64 1/2" 3/4" 96806135 3/4 3 1/4 57 / 2 1/4 4 3/16 1" 96806136 4/8 3 55/64 67 / 2 21/32 4 3/16 4 1/2 1-1/4" 96806137 4 / 13 4 1/2 75 / 2 31/32 4 3/16 4 35/64 1-1/2" 96806138 4 / 15 4 37/64 75 / 2 31/32 4 3/16 4 9/16 Note: Each set contains 2 each - rotating flanges, lever-handled full-ported ball valve, EPDM gaskets, dielectric sleeves. 4 each - 7/16" X 1-3/4" bolts with nuts. Dimensions in inches unless otherwise noted. Materials of construction 74 Center of valve to handle end [D*] Flange Chrome plated steel Valve body Brass Valve ball Chrome plated brass Valve seat PTFE DIelectric sleeve Composite Bolt Chrome plated steel Nut Chrome plated steel Gaskets EPDM Maximum temperature 230 °F (110 °C) Maximum presure 150 psi Approvals IAPMO - #6591 Accessories UP Series Packaged fitting sets GF 15/26/40/43 GF 50 A B Pipe connection 2” NPT D C D Pipe connection E F GU 125 Union TM04 9810 0111 TM04 9808 0111 A B Isolation Valve GU 125 Union Pipe connection Pipe connection D D A C B Material Pump Connection Pipe Connection NPT Solder Compression 3/4" GF15/26 Cast Iron Material Number TM04 9811 0111 TM04 9809 0111 A B C Dimensions (in. / mm) A B C D E F 4-1/4 / 106 3-1/8 / 80 2-3/4 / 67 1/2 / 13 1/2 / 13 3/4 / 20 519601 1" 519602 1-1/4" 519603 1-1/2" 519604 GF40/43 1-1/2" 539605 4-3/4 / 120 3-1/2 / 87 3 / 74 1/2 / 13 1/2 / 13 3/4 / 20 GF50 2" (4-bolt flange) 96409354 5-1/4 /133 4 / 103 - 1/2 / 14 1/2 / 13 3/4 / 20 3/4" 519651 4-1/4 / 106 3-1/8 / 80 2-3/4 / 67 1/2 / 13 1/2 / 13 3/4 / 20 GF15/26 1" 519652 1-1/4" 96409356 GF40/43 1-1/2" 539615 4-3/4 / 120 3-1/2 / 87 3 / 74 1/2 / 13 1/2 / 13 3/4 / 20 GF50 2" (4-bolt flange) 96409355 5-1/4 /133 4 / 103 - 1/2 / 14 1/2 / 13 3/4 / 20 - Bronze 3/4" GU 125 Union Isolation Valves Bronze GU 125 Union 529912 1 / 25 1-7/8 / 46 1-1/14 / 31 5/8 / 16 - 1/2" 529913 3/4 / 20 1-7/8 / 46 3/4 / 20 5/8 / 16 - - 3/4" 529911 3/4 / 20 1-7/8 / 46 1 / 26 5/8 / 16 - - 1/2" 519850 2-1/4 / 57 1-7/8 / 46 1 / 25 5/8 / 16 - - 3/4" 519852 2-1/4 / 57 1-7/8 / 46 1-1/4 / 31 5/8 / 16 - - 519851 2 / 51 1-7/8 / 46 1-1/4 / 31 5/8 / 16 - - 3/4" Notes: GF15/26/40/43 Flange sets to include two flanges, two gaskets, and four nuts and bolts. GF50 Flange sets to include two flanges, two gaskets, and eight nuts and bolts. GU 125 Union Union set to include two nuts, gaskets, and adapters. Dimensions are in inches unless otherwise noted. Approvals (Bronze sets) IAPMO - #6591 75 Accessories UP Series UP-ZV zone valves Specifications Grundfos UP-ZV 24V, 2-way motorized zone valves for hydronic heating or chilled water applications. Standard features • In-line removable actuator for ease of installation and service • manual open/close lever • sealed end switch • silent close-of technology • high gear ratio • forged brass body • removable service cap • high Cv rating. TM04 9803 0111 Approvals Technical data Max. percent glycol: 50 % Fluid temp. range: 32 to 240 °F (0 to 115 °C) Ambient temp. range: 32 to 104 ° F (0 to 40 °C) Max. humidity: 95 % non-condensing Max. static pressure: 15 psi (1 bar) steam Stroke time Valve body: Brass Brass Synchronous hysteresis Class: Class A 24-VAC +/- 10 %, Class 2 5 Watts 7 VA 300 ma 300 ma End (auxiliary) switch models Type: Sealed De-energized position: Normally closed Rating: 0.4A (400 mA) @ 24 VAC (AC/DC) Class 2 Isolated: 76 Manually opened: opened Materials of construction Seat: Actuator motor: In-rush: With power: opened Without power: closed Open: approx. 45 sec. Closed: approx. 10 sec. Run amps: Valve operation: 300 psi (20 bar) Actuator motor Voltage: Valves Yes Stem: Stainless steel Paddle: EPDM O-rings: EPDM Accessories UP Series UP-ZV flow characteristics Max. Close-off ΔP Connection size Flow Coefficient 1/2-inch Sweat 3.5 Cv (3.0 Kv) 30 psi (207 kPa) 3/4-inch Sweat 7.5 Cv (6.5 Kv) 20 psi (138 kPa) 1-inch Sweat 7.5 Cv (6.5 Kv) 20 psi (138 kPa) 3/4-inch NPT 3.5 Cv (3.0 Kv) 30 psi (207 kPa) SWEAT MODELS TM04 9804 0111 NPT MODELS Dimensions [inches] Connections A B 1/2-inch Sweat 1 5/16 2 5/8 C 3/4-inch Sweat 1 3/8 2 5/8 1-inch Sweat 1 11/16 2 5/8 3/4-inch NPT 1 13/16 2 5/8 D E F G H I 3 7/16 4 4 17/32 1 3/16 2 3/8 4 15/16 4 3/16 Note: Dimensions for actuators with or without auxiliary switch. Product number Description 97627415 1/2-inch Sweat, 2-way Valve Body, Normally Closed, with End Switch 97627416 1/2-inch Sweat, 2-way Valve Body, Normally Closed, without End Switch 97627419 3/4-inch Sweat, 2-way Valve Body, Normally Closed, with End Switch 97627420 3/4-inch Sweat, 2-way Valve Body, Normally Closed, without End Switch 97627421 1-inch Sweat, 2-way Valve Body, Normally Closed, with End Switch 97627422 1-inch Sweat, 2-way Valve Body, Normally Closed, without End Switch 97627417 3/4-inch NPT, 2-way Valve Body, normally Closed, with End Switch 97627418 3/4-inch NPT, 2-way Valve Body, normally Closed, without End Switch Service Product number Description 97627423 Actuator 24-VAC, Normally Closed with End Switch 97627424 Actuator 24-VAC, Normally Closed without End Switch 77 Accessories UP Series Replacement flange gaskets 78 For use with flange set Material number Description Shipping weight [oz.] GF 15/26 510179 Single gasket for 1-1/4" flange 4 GF 40/43 530244 Single gasket for 1-1/2" flange 4 GF 50 96409353 Single gasket for 2" flange 4 GF 65 550097 Single gasket for 2-1/2" flange 4 GF 80 560185 Single gasket for 3" flange 4 GF 100 570008 Single gasket for 4" flange 4 GU 125 520089 Single gasket for GU 125 union 4 Submittal data UP Series Submittal data Company name ................................................. Prepared by ....................................................... Phone number (.......)......................................... Fax number (.......).............................................. Date:..................... Page 1 of:.................... Quote number:................................................... Client information Project title:.............................................................................................. Client name:............................................................................................... Reference number:................................................................................... Client number:............................................................................................ Client contact:.......................................................................................... Client phone:.............................................................................................. Location information For:............................................................................................................ Unit:........................................................................................................... Site:........................................................................................................... Service:...................................................................................................... Address:..................................................................................................... City:.............................. State:............................ Zip code:...................... Technical data Motor information Flow (GPM):.............................................................................................. HP:............................................................................................................. Head (Ft)................................................................................................... Phase:....................................................................................................... Motor:....................................................................................................... Voltage:..................................................................................................... Max. liquid temp.:....................................................................................... Enclosure:................................................................................................. Min. liquid temp.:........................................................................................ Min. required inlet pressure:....................................................................... Connection type and size:........................................................................... Pump information Model information from type key and codes: Example: UP-S-15-58-FC........................................................................... Quantity required:.................................................................................... NPSH required at duty point:...................................................................... Minimum required flow:............................................................................ Product guide additional information pages Materials page number:.............................................................................. Performance curve page number:............................................................... Technical data page number:...................................................................... Motor data page number:............................................................................ Custom-built pump information (optional):.................................................................................................................................................................. ................................................................................................................................................................................................. Additional information:................................................................................................................................................................................................. ................................................................................................................................................................................................. 79 Submittal data UP Series This page intentionally left blank. 80 Further product documentation UP Series WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: • Catalog • Literature • Service • Sizing • Replacement • CAD drawings. Catalog This section is based on fields of application and pump types, and contains • technical data • curves (QH, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation • product photos • dimensional drawings • wiring diagrams • quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as • data booklets • installation and operating instructions • service documentation, such as Service kit catalog and Service kit instructions • quick guides • product brochures, etc. Service This section contains an easy-to-use interactive service catalog. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, his section contains service videos showing you how to replace service parts. Visit our U.S. website at www.grundfos.us 81 Further product documentation Sizing 0 UP Series 1 This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to • select the most suitable and efficient pump for your installation • carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. • analyse your selected pump via the built-in life cycle cost tool • determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings: • .dxf, wireframe drawings • .dwg, wireframe drawings. 3-dimensional drawings: • .dwg, wireframe drawings (without surfaces) • .stp, solid drawings (with surfaces) • .eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS CD-ROM Visit our U.S. website at www.grundfos.us 82 WinCAPS is available on CD-ROM and updated once a year. UP Series Notes 83 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence L-UP-PG-001 Rev. 0311 US Repl. 1109 © 2007, 2009-2010 Grundfos Pumps GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 www.grundfos.com GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Canada Phone: +1-905 829 9533 Telefax: +1-905 829 9512 The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide. Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L. Mexico 66600 Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.7 Linearized : Yes Page Mode : UseNone Page Count : 84EXIF Metadata provided by EXIF.tools