GRUNDFOS PRODUCT GUIDE

Large UP, UPS
Series 200 circulator pumps
60 Hz

Large UP, UPS

Table of contents

1.

2.

3.
4.
5.

6.

7.

8.

9.

Product introduction

3

Introduction
Terminal box modules
Applications
Features and benefits
Identification

3
3
3
3
4

Product overview

5

Performance range, UPS pumps
Performance range, UP pumps

5
6

Product range

7

Pump overview

7

Cross-reference guide

8

Armstrong, B&G and TACO to Grundfos

8

Construction

10

Construction
Material specification
Sectional drawing
Motor
Stator housing
Rotor can
Shaft with rotor
Bearing plate
Impeller
Pump housing

10
11
11
12
12
12
12
12
12
12

Operating conditions

13

Pumped liquids
Temperature limits
Other technical data
Electrical data
Supply voltage tolerances
Terminal box
Insulation class

13
13
13
14
14
14
14

Functions

15

Functions
Description of functions
Standard module indicator lights
Variable frequency drive operation
Pumps with protection module
Protection module indicator lights
Pumps with relay module
Relay module indicator lights
Signal output of relay module
Two pumps plumbed in parallel

15
16
17
17
17
18
18
18
18
18

Technical data

19

Technical data, UPS
Curve conditions

19
24

Curve charts and technical data

25

10. Accessories and spare parts
Packaged fitting sets
Terminal box electrical components

2

62
62
62

11. Further documentation
WebCAPS
WinCAPS

63
63
64

UP, UPS Series 200

1

Introduction

Applications

The Grundfos UP(S) Series 200 line of wet rotor
circulators is unique to commercial building
services. Most competitor pumps are dry runners.
UP(S) wet rotor circulators, on the other hand, are
designed so that the water being pumped surrounds
the rotor, cooling and lubricating the shaft and
bearings.

The pumps are designed for circulation of liquids in
heating and air-conditioning systems. They can also
be used in domestic hot-water systems.
Applications for the UP(S) pumps include:
• Heating systems for apartments, colleges, hospitals,
institutions and schools
• hot water recirculation for hotels, colleges
institutions, hospitals, and apartments
• large residential heating
• snow melt.
To ensure optimum operation, the dimensioning range
of the system must fall within the performance range of
the pump. See sections 6. Operating conditions on
page 13 and 8. Technical data on page 19.

Product introduction

1. Product introduction

GrA3223, GrA3217

Pumped liquids

Fig. 1

Grundfos UP, UPS Series 200 circulator pumps

Wet rotor design eliminates the need for a fan to cool
the motor. Fans are often a source of noise and
vibrations that can resonate throughout a building via
the pipework. Eliminating the fan results in very quiet
operation.
UP(S) Series 200 pumps are available in cast iron
construction for closed (heating and air conditioning)
and bronze construction for open (domestic hot water)
systems.
Both cast iron and bronze UP(S) Series 200 pumps
utilize laser-welded stainless steel impellers to achieve
high pump efficiency.
The standard UP(S) motors are suitable for variable
speed drive applications.

Terminal box modules
UPS pumps are equipped with a standard or protection
module in the terminal box. Pumps with standard
module must be connected to the power supply via an
external contactor, whereas pumps with protection
module can be connected directly to the power supply.
For further information about the different modules,
see pages 17 through 18.

Grundfos UP, UPS Series 200 pumps are suitable for
pumping thin, clean, non-aggressive and
non-explosive liquids, not containing any solid
particles, fibers or mineral oil.
In domestic hot-water systems it is advisable to use
bronze pumps only for water with a degree of hardness
lower than approx. 14°dH. For water with a higher
degree of hardness, a Grundfos TP dry-rotor pump is
recommended.
The pumps must not be used for the transfer of
flammable liquids such as diesel oil and gasoline.
For liquid temperature, see section 6. Operating conditions on page 13.

Features and benefits
The Grundfos range of UP(S) Series 200 circulator
pumps offer many beneficial features:
• Quiet
• maintenance-free
• UPS pumps have a 2 or 3 speed switch, which
increases the comfort level for the application
• small profile (one piece vs. three piece)
• sealless, which eliminates worries about hot water
leakage
• pumped water lubricates the shaft and bearings so
there is no oil to leak
• no couplers to change.

3

UP, UPS Series 200

1
Product introduction

Identification
Type key
Example

UPS

50

-40

(/2)

F

(B)

Type range
- UP: Single-speed pump
- UPS: Two- or three-speed pump
Nominal flange diameter [mm]
Max. head [dm]*
Number of motor poles (stated if available both as 2- and 4-pole motor)
Pump with flanges
Pump with bronze housing
*With the exception of the following pump types, where the number is to be considered as a reference number:
UP 53-45, UP 53-46, UPS 53-55/57 and UPS 75-69

Nameplate

1

9
10

UPS 50-40 F

5

P/N:96402816

Model:C
PC:0635
EMPLOYER UNIQUEMENT A L’INTERIERUR

8

4

Example of nameplate
Description

1

Type code

2

Product number

3

Model designation

4

Production code (year + week)

5

Country of origin

6

Number of phases and rated voltage

7

Current at speeds 1, 2, 3

8

Power at speeds 1, 2, 3

9

Direction of rotation

10

Approvals

11

Temperature limits

12

Rated frequency

13

Capacitor size

14

Locked Rotor Amps

15

Insulation class

US

CSA ENCL. 2/BOITIER DE YPE 2

3 208-230V 60Hz
P1 (W)
I 1/1 (A)
1 0.54 1 150

170
2 0.66 2
270
3 1.40 3

F
4.0 (A)
ClassF

LRA

11

APPROVED FOR
WATER: MAX T. 120°C/248F

FOR INDOOR USE ONLY

7

Pos.

C

MADE IN GERMANY

6

Fig. 1

LISTED 1Z28
WATER-CIRCULATING PUMP
MIN LIQUID T. -10°C/+14° F
MAX LIQUID T. 120°C/+248° F

12
13
14
15

TM03 7712 4806

2
3
4

UP, UPS Series 200

2
Product overview

2. Product overview
Performance range, UPS pumps
The curves show maximum performance curves for the
UPS range:
• single-voltage pumps
• two- and three-speed pumps.

H
[m]
20

H
[ft]

UPS

60
40-240

50

60 Hz

50240

40
32-160

10
9

30

8

40-80/2

53-5
5/57

7
6

50-160
75-69

40-160

20
32-80

5

5080 /

2

40-80/4

80-80

50

15

-8
0/4

4

3

80-160

10
8

2
6
32-40

40-40

50-40

80-40

100-40

4
1
3

2
15

3

20

4

30

5

6

7

40

8

9 10

60

80

100

20

150

30

200

300

Q [US G PM]
40

50

60

Q [m³/h]

TM00 9582 5106

10

5

UP, UPS Series 200

2
Product overview

Performance range, UP pumps
The curves show maximum performance curves for the
UP range:
• dual-voltage pumps
• single-speed pumps.

H
[m]

H
[ft]

UP
60 Hz

40

10
9

30

8

43-110

7
43-70
6

20
53-46

5

53-45
15

4

3

10

8

2
6

5

4
15

20

30

40

60

80

100

150

Q [US GPM]
3

4

5

6

7

8

9

10

20

30

Q [m³/h]

6

TM02 5598 4706

10

UP, UPS Series 200

3
Product range

3. Product range
UPS range
Voltage [V]

Poles

Pump type
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS
UPS

32-40 F
32-80 F
32-160 F
40-40 F
40-80/2 F
40-80/4 F
40-160 F
40-240 F
50-40 F
50-80/2 F
50-80/4 F
50-160 F
50-240 F
53-55/57 F
75-69 F
80-40 F
80-80 F
80-160 F
100-40 F

1 x 115

1 x 230

3 x 208-230

3 x 460

3 x 575

2

4

●
●
●
●
●
●
●
—
●
●
●
—
—
●
—
—
—
—
—

●
●
●
●
●
●
●
●
●
●
●
●
—
●
●
—
—
—
—

●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●

●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
—
●
●

●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
●
—
●
●

—
●
●
—
●
—
●
●
—
●
—
●
●
●
●
—
—
●
—

●
—
—
●
—
●
—
—
●
—
●
—
—
—
—
●
●
—
●

Canada only

UP range
Voltage [V]

Poles

Pump type
UP
UP
UP
UP

1 x 115/230 V

2

4

●
●
●
●

●
●
●
●

—
—
—
—

43-70 F
43-110 F
53-45 F
53-46 F

Pump overview
Model
UP 43-70 F
UP 43-110 F
UP 53-45 F
UP 53-46 F
UPS 32-40/4
UPS 32-80/2
UPS 32-160/2
UPS 40-40/4
UPS 40-80/2
UPS 40-80/4
UPS 40-160/2
UPS 40-240/2
UPS 50-40/4
UPS 50-80/4
UPS 50-80/2
UPS 50-160/2
UPS 50-240/2
UPS 53-55/57 F
UPS 75-69 F
UPS 80-40/4
UPS 80-80/4
UPS 80-160/2
UPS 100-40/4

Flow
[US gpm]

Head
[ft]

Ph

Max.
[rpm]

Flange

15-100
15-105
15-100
15-105
9-52
9-67
9-76
13-85
13-105
13-120
13-110
13-130
20-125
20-160
20-150
20-170
20-180
20-150
20-170
30-200
30-260
30-275
30-270

1-23
1-37
1-23
1-37
1-11
1-25
1-45
1-11
1-30
1-25
1-46
1-62
1-12
1-24
1-30
1-46
1-62
1-30
1-46
1-13
1-25
1-49
1-12

1
1
1
1
1-3
1-3
1-3
1-3
1-3
1-3
1-3
1-3
1-3
1-3
1-3
1-3
3
1-3
1-3
3
3
3
3

3450
3450
3450
3450
1750
3450
3450
1750
3450
1750
3450
3450
1750
1750
3450
3450
3450
3450
3450
1750
1750
3450
1750

1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes
2", 2.5", 3" non ANSI 4 bolt w/ (4) 0.63" dia. holes
2", 2.5", 3" non ANSI 4 bolt w/ (4) 0.63" dia. holes
1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes
1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes
2", 2.5", 3" non ANSI 4 bolt w/ (4) 0.56" dia. holes
3" ANSI 125# R.F.
3" ANSI 125# R.F.
3" ANSI 125# R.F.
3" ANSI 125# R.F.
4" ANSI 125# R.F.

Flange type
GF 40/43
GF 40/43
GF 53
GF 53
GF 15/26
GF 15/26
GF 40/43
GF 40/43
GF 40/43
GF 40/43
GF 40/43
GF 40/43
GF 50
GF 50
GF 50
GF 50
GF 50
GF 53
GF 80
GF 80
GF 80
GF 80
GF 100

7

UP, UPS Series 200

4
Cross-reference guide

4. Cross-reference guide
Armstrong, B&G and TACO to Grundfos
Manufacturer

Armstrong

TACO

Port-to-port
length
[in]

Flange size
[in]

ARMflo E21

8.50

1.50

UP43-110F

8.50

1.50

ARMflo E23

8.50

1.50

UP43-110F

8.50

1.50

S 45

10.00

2.50, 3

UP53-45F

9.88

2.00, 2.50, 3.00

S 46

10.00

2.50, 3

UP53-46F 

9.88

2.00, 2.50, 3.00

S 55

12.00

3.00

UPS53-55/57F

11.88

2.00, 2.50, 3.00

S 57

12.00

3.00

UPS53-55/57F

11.88

2.00, 2.50, 3.00

S 69

14.25

3.00

UPS75-69F 

14.00

2.00, 2.50, 3.00

H51

11.50

1.00

UPS32-80/2

11.00

0.75 to 1.50

H52

11.50

1.00

UPS32-80 

11.00

0.75 to 1.50

H53

11.50

1.50

UPS40-160/2

11.50

1.50

H54

11.50

2.00

UPS50-80/2

11.50

2.00

H63

13.50

1.50

UPS32-160/2 

13.50

1.50

H64

13.50

1.50

UPS32-160/2 

13.50

1.50

H65

13.50

1.50

UPS40-240/2 

13.50

1.50

H66

14.00

2.00

UPS50-160/2

14.00

2.00

H67

14.00

2.00

UPS50-160/2 

14.00

2.00

H68

14.00

2.00

UPS50-240/2 

14.00

2.00

1050 1B (0.25 Hp)

11.50

1.00

UPS32-80/2 

11.00

0.75 to 1.50

1050 1-1/4B (0.25 Hp)

11.50

1.25

UPS32-80/2 

11.00

0.75 to 1.50

1050 1-1/2B (0.25 Hp)

11.50

1.50

UPS32-80/2

11.00

0.75 to 1.50

1050 2B (0.33 Hp)

11.50

2.00

UPS50-80/4

11.50

2.00

1050 2B (0.50 Hp)

11.50

2.00

UPS50-80/4

11.50

2.00

1050 2B (0.75 Hp)

11.50

2.00

UPS50-80/4 

11.50

2.00

1060 1-1/2 D (0.50 Hp)

13.50

1.50

UPS32-160/2

13.50

1.50

1060 1-1/2 D (0.75 Hp)

13.50

1.50

UPS32-160/2 

13.50

1.50

1060 1-1/2 D (1.50 Hp)

13.50

1.50

UPS40-240/2

13.50

1.50

1060 2D (0.75 Hp)

14.00

2.00

UPS50-160/2 

14.00

2.00

1060 2D (1.00 Hp)

14.00

2.00

UPS50-160/2

14.00

2.00

1060 2D (1.50 Hp)

14.00

2.00

UPS50-160/2

14.00

2.00

1060 2D (2.00 Hp)

14.00

2.00

UPS50-240/2 

14.00

2.00

120

11.00

2.00

UPS32-40/4

11.00

0.75 to 1.50

131

13.63

3.00

UP53-45F

10.00

2.00, 2.50, 3.00

133

13.63

3.00

UPS53-55/57 

11.88

2.00, 2.50, 3.00

1600

10.25

1.50

UPS32-80/2 

11.00

1.50

1610

10.25

1.50

UPS32-80/2

11.00

1.50

1612

13.50

1.50

UPS32-160/2 

13.50

1.50

1614

13.50

1.50

UPS32-160/2 

13.50

1.50

1616

14.50

2.00

UPS40-240/2

13.50

1.50

1630

13.50

2.00

UPS50-80/4

11.50

2.00

1632

13.50

2.00

UPS50-160/2

14.00

2.00

1634

13.50

2.00

UPS50-160/2

14.00

2.00

1636

16.50

2.00

UPS50-240/2

14.00

2.00

1638

16.50

2.00

UPS50-240/2

14.00

2.00

Model

Grundfos model

Port-to-port
length
[in]

Flange size
[in]

 Bronze version to be used in open systems.
 Replacement model requires piping and/or flange modification.

Disclaimer: This cross-reference is a guide only. Use individual technical data sheets for correct comparison.

8

UP, UPS Series 200

B&G

Model

Port-to-port
length
[in]

Flange size
[in]

2-1/2"

10.00

2.50

LD3

10.00

HD3

Port-to-port
length
[in]

Flange size
[in]

UP53-45F 

9.88

2.00, 2.50, 3.00

3.00

UP53-45F 

9.88

2.00, 2.50, 3.00

10.00

3.00

UP53-46F

9.88

2.00, 2.50, 3.00

PD-35

12.00

3.00

UPS53-55/57F

11.88

2.00, 2.50, 3.00

PD-37

12.00

3.00

UPS53-55/57F

11.88

2.00, 2.50, 3.00

PD-38

14.50

3.00

UPS75-69F

14.00

2.00, 2.50, 3.00

PD-40

14.50

3.00

UPS50-160/2 

14.00

2.00

601

11.00

1.00

UPS32-80/2 

11.00

0.75 to 1.50

602

11.00

1.00

UPS32-80/2

11.00

0.75 to 1.50

603

11.00

1.00

UPS50-80/2

11.50

2.00

604

11.00

1.25

UPS32-80/2 

11.00

0.75 to 1.50

609

11.50

1.50

UPS40-160/2 

11.50

1.50

610

11.50

2.00

UPS50-80/4 

11.50

2.00

621

13.50

2.00

UPS40-80/4

13.50

1.50

614

13.50

1.50

UPS40-240/2

13.50

1.50

615

13.50

2.00

UPS50-160/2

14.00

2.00

616

13.50

2.00

UPS50-160/2

14.00

2.00

622

13.50

1.50

UPS32-160/2

13.50

1.50

623

13.50

1.50

UPS40-240/2

13.50

1.50

617

13.50

1.50

UPS40-240/2

13.50

1.50

624

14.00

2.00

UPS50-160/2

14.00

2.00

625

14.00

2.00

UPS50-240/2

14.00

2.00

60-11

11.00

1.25

UPS32-80/2

11.00

0.75 to 1.50

60-13

11.50

1.50

UPS40-160/2 

11.50

1.50

60-14

11.50

2.00

UPS50-80/2

11.50

2.00

60-15

13.50

1.50

UPS32-160/2

13.50

1.50

60-16

13.50

1.50

UPS32-160/2

13.50

1.50

60-17

13.50

1.50

UPS40-240/2

13.50

1.50

60-19

14.00

2.00

UPS50-160/2

14.00

2.00

60-20

14.00

2.00

UPS50-160/2

14.00

2.00

60-21

14.00

2.00

UPS50-240/2

14.00

2.00

Grundfos model

Cross-reference guide

Manufacturer

4

 Bronze version to be used in open systems.
 Replacement model requires piping and/or flange modification.

Disclaimer: This cross-reference is a guide only. Use individual technical data sheets for correct comparison.

9

UP, UPS Series 200

5
Construction

5. Construction
Construction

TM03 7880 5106

UP(S) Series 200 pumps are of the canned rotor type,
i.e. pump and motor form an integral unit without shaft
seal and with only two gaskets for sealing.
The bearings are lubricated by the pumped liquid.
Attention has been focused on using as few materials
as possible, and the use of materials that might cause
problems in connection with disposal have been
omitted.

Features:
• UPS motors are two- or three-speed motors.
UP motors are single-speed dual-voltage motors.
• Stainless steel rotor can, bearing plate and rotor
cladding.
• Stator housing in aluminum alloy.
• Cast iron or bronze pump housing.
• Stator with built-in thermal overload switch.

Fig. 2

10

Exploded view of a UP(S) Series 200 pump

UP, UPS Series 200

5

Pos. Description

Material

1

Terminal box

2

Inspection screw

Brass with nickel

3

Nameplate

Composite PA66

AISI/ASTM

Composite PA66

Pos. Description
9
10

Material

Thrust bearing

Carbon MY 106

Bearing plate

Stainless steel

Inner bearing ring

Aluminium oxide/SiC

AISI/ASTM

AISI 304

Stator housing

Aluminium AlSi10Cu2

11

Stop ring

Stainless steel

Stator windings

Copper wire

12

Split cone

Stainless steel

AISI 303

Stator caps

Composite PETP

13

Impeller

Stainless steel

AISI 304

5

Cheese-head screw

Steel 8.8

14

Nut

Stainless steel

AISI 303

6

O-rings

EPDM rubber

15

Neck ring

Stainless steel/PTFE

AISI 304

Outer bearing ring

Aluminium oxide/SiC

Rotor can

Stainless steel

AISI 304

16

Pump housing

Shaft (cast-iron pumps)
Shaft (bronze pumps)

Stainless steel

AISI 303
AISI 316

17

Anti-friction ring

PTFE

Rotor cladding

Stainless steel

AISI 304

18

Splash protector

Stainless steel

Bearing

Tungsten carbide

4

7

8

Construction

Material specification

Cast iron EN-GJL-250
Bronze CuSn10, DIN 1705

ASTM B505
and B271
AISI 303

TM02 1397 0907

Sectional drawing

Fig. 3

Sectional view

11

UP, UPS Series 200

5
Construction

Motor

Rotor can

The motor, pos. 4, is a 2- or 4-pole, asynchronous
squirrel-cage motor. As the motor is cooled by the
pumped liquid, the noise level is very low.

The rotor can (pos. 7) is made of drawn steel sheet
and fitted with an inspection screw directly at the top.
There is an O-ring seal between the inspection screw
and the rotor can. For reasons of safety, the hole for
the inspection screw will deflect a possible jet of liquid
if the inspection screw is removed.
The outer radial bearing is fitted into the top of the
rotor can.

Stator housing

TM02 1398 1101

Pressure die-cast aluminum stator housing can be
turned to change the position of the terminal box.
The stator housing has eight drain holes to enable
condensed water to escape. The vent hole under the
terminal box allows the water to evaporate from the
stator. The drain holes must point downwards.
The permissible terminal box positions are shown in
the drawing below. The positions apply to both vertical
and horizontal mounting.

Fig. 4

Possible terminal box positions

Note: The terminal box must only be turned to the
above positions.
The drawing below shows the standard box position.

Shaft with rotor
The shaft (pos. 8) is made of stainless steel and
equipped with two tungsten carbide bearings.
To further improve the internal circulation of the
pumped liquid in the rotor can, the shaft of 4-pole
motors is fitted with a small rotor impeller.
The rotor is made of soft-annealed iron lamination and
provided with copper or brass bars. The short-circuit
rings are made of copper.
The rotor is encapsulated in a thin stainless steel
cladding and dynamically balanced.
The thrust bearing is secured to the shaft in a
spherically flexible suspension.

TM03 2260 4005

Bearing plate

Fig. 5

Standard terminal box position

The nameplate can be turned in steps of 45°.
The positions of the terminal box and the nameplate
are changed as described above.
The stator wires are self-bonding. The wires and the
terminal box are connected by a terminal plug.
The stator incorporates a thermal overload switch for
protection of the motor if the winding temperature
becomes too high.

12

The bearing plate (pos. 10) is made of stainless steel.
The inner radial bearing is pressed into the bearing
plate, ground and honed. The relatively large bearing
plate surface means that motor heat is effectively
carried away by the pumped liquid.

Impeller
The stainless steel impeller (pos. 13) is of the radial
type with curved blades. It is secured to the shaft by a
split cone and nut (left-hand thread).

Pump housing
The pump housing (pos. 16) is available in cast iron or
bronze. All pump housings are flanged for the
individual markets.
See also section 4. Cross-reference guide on page 8
and section 5. Construction on page 10 concerning
flanges and port-to-port lengths.
The pump housing is of the in-line type. A stainless
steel/PTFE neck ring minimizes the recirculation and
improves pump efficiency.
The bottom of the housing has threaded holes for
fastening to a baseplate.

UP, UPS Series 200

6

Pumped liquids

Other technical data

CAUTION: This pump is intended for use with water
only.
Grundfos UP(S) pumps can be used to circulate
• Potable hot water
• Water for hydronic heating
• Water/glycol mixtures up to 50/50
• Cooling water.
In domestic hot-water systems it is advisable to use
a bronze pump (UP(S) model) only for water with a
degree of hardness lower than 14 grains per gallon of
hardness. For water with a higher degree of hardness,
a direct coupled TP pump is recommended.
If the pump is installed in a heating system, the water
should meet the requirements of accepted standards
on water quality in heating systems.
In water/glycol mixtures, in order to prevent the
glycol from degrading, temperatures above those for
which the fluid is rated should be avoided and time
spent at high temperatures minimized.
It is also important that the system is cleaned and
flushed prior to the installation of the glycol mixture.
In order to avoid problems with corrosion or
precipitation, the glycol fluids should be checked and
maintained regularly. If further dilution of the
supplied glycol is required, follow the requirements of
the supplier of the glycol.
The pump is lubricated and cooled by the liquid being
pumped. Therefore, the pumped liquid must always be
allowed to circulate through the pump. Extended
periods without circulation will cause premature wear
to the bearings and excessive motor heat. The
pumped liquid must also meet the following
requirements.
The pumping of liquids with densities or kinematic
viscosities higher than those of water will cause
– a considerable pressure drop
– a drop in the hydraulic performance
– a rise in the power consumption.
In these situations, contact Grundfos for assistance.

Relative humidity: Max. 95 %.
Sound-pressure level: The sound-pressure level
of the pump is lower than 41 dB(A) (reference: 20
mPa).
Max. working pressure: 145 psi (10 bar).
Approvals: See the pump nameplate.

Operating conditions

6. Operating conditions

Inlet pressure
To avoid cavitation noise, the following minimum
pressures are required at the pump suction flange:
Liquid temperature
UP(S) model

UPS 32-40

167 °F
(75 °C)

194 °F
(90 °C)

230 °F
(110 °C)

[psi]

[ft]

[psi]

[ft]

[psi]

[ft]

0.7

1.6

2.2

5.1

21.0

48.5

UPS 32-80

0.7

1.6

5.1

11.8

23.9

55.2

UPS 32-160

11.6

26.8

16.0

37.0

34.1

78.8

UPSD 40-40

0.7

1.6

4.4

10.2

23.2

53.6

UPS 40-80/4

0.7

1.6

1.5

3.5

18.1

41.8

UPS40-80/2

6.5

15.0

10.9

25.2

29.0

67.0

UPS 40-160

5.1

11.8

9.4

21.7

27.6

63.8

UPS 40-240

11.6

26.8

16.0

37.0

34.1

78.8

UPS 50-40

0.7

1.6

2.9

6.6

21.8

50.4

UPS 50-80/4

0.7

1.6

4.4

10.2

23.2

53.6

UPS 50-80/2

4.4

10.2

8.7

20.1

26.8

61.9

UPS 50-160

11.6

26.8

16.0

37.0

34.1

78.8

UPS 50-240

10.2

23.6

14.5

33.5

32.6

75.1

UPS 53-55/57

4.4

10.2

8.7

20.1

26.8

61.9

UPS 75-69

11.6

26.8

16.0

37.0

34.1

78.8

UPS 80-40

11.6

26.8

16.0

37.0

34.1

78.8

UPS 80-80

14.5

33.5

18.9

43.7

37.0

85.5

UPS 80-160

21.8

50.4

26.1

60.3

43.5

100.5

UPS 100-40

27.6

63.8

31.9

73.7

50.0

115.5

UP 43-70F

0.7

1.6

4.8

11.0

15.4

35.6

UP 43-110

3.6

8.4

8.2

19.0

18.9

43.7

UP 53-45

2.9

6.6

7.5

17.3

18.1

41.8

UP 53-46

1.1

2.5

5.8

13.4

16.4

37.9

Temperature limits
Ambient air temperature

32 °F to 104 °F (0 °C to 40 °C)

Fluid temperature,
open systems

140 °F (60 °C).

Fluid temperature,
closed systems

UPS pumps:

248 °F (120 °C).

UP pumps:

230 °F (110 °C).

13

UP, UPS Series 200

6
Operating conditions

Electrical data

Insulation class

Supply voltage and frequency

Pump type

UPS: 115 V, 230 V, 1-phase 60 Hz, 208-230 V, 460 V,
575 V, 3 phase 60 Hz.
UP: 115 V, 230V, 1-phase 60 Hz, 460 V, 575 V,
3-phase 60Hz.
Back-up fuse: Max. 10 A.
Enclosure class: IP 44 indoor use only.

Supply voltage tolerances
The motors meet the requirements to temperature rise
at - 6 / +6 %.
Furthermore, the motors have been tested at
-10 / +10 % of the voltage range. During these tests,
the motors operate without problems and without being
thermally cut out.
The motor voltage tolerances are intended for power
supply voltage variations. They should not be used for
running motors at other voltages than those stated on
the name plates.
Variable speed applications
All 3 x 460 V, 3 x 575 V and 3-speed 3 x 208-230 V
pumps with standard module are suitable for frequency
converter applications. Please refer to section Variable
frequency drive operation on page 17 for
further information.

Insulation class

UPS

1 x 115 V
1 x 230 V

3 x 208-230 V
3 x 460 V
3 x 575 V

32-40

F

F

32-80

F

F

32-160

H

F

40-40

F

F

40-80/4

H

H

40-80/2

F

F

40-160

H

H

40-240

H

H

50-40

F

F

50-80/4

H

H

50-80/2

H

F

50-160

H

H

50-240

—

H

53-55/57

H

F

75-69

H

H

80-40

—

H

80-80

—

H

80-160

—

H

100-40

—

H

Pump type

Insulation class

UP

Terminal box

TM00 9133 4596

Indicator lights and speed
indication

Fig. 6

F

43-110

F

53-45

F

53-46

F

Thermal overload switch
Voltage

250 V AC

Current

cos phi = 1.0: 2.5 A
cos phi = 0.6: 1.6 A

Terminal box

The terminal box with cover (pos. 1) is made from
black composite material.
The terminal box is equipped with:
• 1 x 1½" NPT screwed cable entry for mains
connection, to be fitted during installation.
• 1 x M16 screwed cable entry for capacitor
connection (only single-phase pumps)
• 2 x indicator lights (single-phase pumps with
standard module have just one).
Note: UPS pumps only.
• window for indication of speed.
Note: UPS pumps only.
The terminal box is fastened to the stator housing with
screws and connected to the stator by a terminal plug.

14

1 x 115/230 V

43-70

Start/stop input (relay module)
External potential-free contact.
Maximum load: 250 V, 1.5 mA.
Minimum load: 100 V, 0.5 mA.
Operating/fault signal output (relay module)
Internal potential-free changeover contact.
Maximum load: 250 V, 2 A, AC.
Minimum load: 5 V, 100 mA, DC.

UP, UPS Series 200

7
Functions

7. Functions
Functions
Additional terminal box
options

UPS terminal box includes

Pump model

UPS 32

UPS 40

UPS 50

UPS 53-55/57

UPS 75-69

UPS 80

UPS 100

Voltage options

Speed
switch

1 x 115/230

■

3 x 208/230

■

3 x 460

Δ

3 x 575 

Δ

1 x 115/230

■

3 x 208/230

■

3 x 460

Δ

3 x 575 

Δ

1 x 115/230

■

3 x 208/230

■

3 x 460

Δ

Standard
module

Protection
module

Terminal
block

Protection
module

Relay
module

●

●

■

External
contactor
required

●

■
■
■

3


3

❑

2

❑

■

●

■

●

●

■
■



3

❑

2

●

■

●

●

■

3 x 575 

Δ

1 x 115/230

■

■

■
●

1 x 230

■

■

●

3 x 208/230

■

■

●

●



3

❑

2

❑

2
3
3



3
2

3 x 460

Δ

■

❑

Δ

■

❑

1 x 230

■

3 x 208/230

■

3 x 460

■

3 x 575 

Δ

●

■
●
■

1 x 115/230

■

3 x 208/230

■

3 x 460

Δ

■
■

3 x 575 

Δ

1 x 115/230

■

3 x 208/230

■

3 x 460

Δ

3 x 575 

Δ

UP 43-70

1 x 115/230

●

■

■

■

3


3

❑

2

●
●

●

3


3

❑

2

❑

2

●
■

■

●
■

●

2
3

●

■

2
3

3 x 575 

■

2
3

❑

■

Number of
speeds

3


3

❑

2

■

❑

2

■

❑

1

UP 43-110

1 x 115

■

❑

1

UP 53-45

1 x 115/230

■

❑

1

UP 53-46

1 x 115/230

■

❑

1

 Canada only
 Standard
 The speed is changed by reconfiguring the jumper positions, located in the terminal box.
 Optional
❑ Required
 External contactor is not required when using the Protection Module option.
Standard module: Indicator lights with no motor protection. For motor protection, use Protection Module for 1 x 115/230 V and 3 x 208/230 V units or
use an external contactor.
Protection module: Indicator lights with built-in motor protection. Connect directly to line voltage.
Note: Pumps with protection module must not be connected to a variable frequency drive (VFD).
Relay module: Indicator lights with signal output for external control or fault indication (1 x 115/230 V or 3 x 208/230 V units only).
External contactor required: Pump must be connected to line voltage via an external contactor. The contactor is to be connected to the pump’s build-in
thermal overload terminals. The speed is changed by orientation of the internal jumpers.

15

UP, UPS Series 200

7
Functions

Description of functions

Indicator lights and
speed indication

TM00 9747 0602

Three-speed pumps

TM00 9235 3802

Speed switch

Fig. 7

3 x 208/230V terminal box

Fig. 10 UPS Series 200 pump with terminal box mounted

Two-speed pumps
All UPS pumps with 3 x 460 V & 575 V terminal boxes
are fitted with a special two-speed terminal block.

By means of the speed switch, the pump performance
can be adjusted to suit the system in question.
For 1 x 115/230 V and 3 x 208/230 V three-speed
pumps only. The module is located inside the terminal
box. It has three positions:
L3

P2 P1

SPEED

Fig. 8

Speed switch module

T6

T1

Fig. 11 3 x 460 V & 575 V terminal box

The speed is changed by changing the jumper
positions.

Single-phase
pumps

Three-phase
pumps

1

approx. 60%

approx. 70%

The pump must be connected to the mains via an
external contactor. The contactor is to be
connected to the pump’s built-in thermal overload
switch (terminals P1 and P2) to protect the pump
against overheating at both speeds.

2

approx. 80%

approx. 85%

Speed selection (two-speed, 3 x 460 V and 575 V)

3

100%

100%

Speed in % of maximum speed
Switch
position

The speed setting in the terminal box can be changed
to two positions. The speed in the two positions
appears in the table below

Note: UP pumps runs at 100%.

Change to a lower speed enables considerable
reduction in energy consumption and less noise in the
system.

2
Q

Fig. 9

H

H

1

3
Q

Pump performance at the three speeds

Q

TM00 9247 4595

H

16

T2

Jumpers

L1

L2
T4

SPEED
TM00 9583 4996

SPEED

T3

TM02 5740 3202

T5

Speed step

Speed in % of maximum

1

Approx. 75%

2

100%

Single-speed pumps
UP pumps (1 x 115/230 V)
UP pumps are single-speed pumps with a 1 x 115
V/230 V terminal box with a dual-voltage terminal
block. See fig. 12.

UP, UPS Series 200

7
Functions

Single-phase pumps
Single-phase pumps incorporate a green indicator light
only:
Jumpers

L

Indicator light

N

On

The electricity supply has been switched on.

Off

The electricity supply has been switched off, or
the pump has been cut out by the thermal
overload switch.

TM02 5761 3902

P2 P1 T1 T5 T3 T4 T2 T8

Fig. 12 1 x 115/230 V terminal box

Three-phase pumps
Three-phase pumps have a green and a red indicator
light:
Indicator lights

The voltage is changed by changing the orientation of
the jumpers. See fig. 12.
The pump must be connected to the power supply via
an external switch.
The UP pumps are equipped with a built-in, automatically resetting terminal overload switch, protecting the
pump at both 115 V and 230 V. The built-in terminal
overload switch (terminals P1 and P2) can optionally
be connected to external overload protection.

Pumps with standard module

TM00 9237 4597

Standard module

Speed switch

Description

Fig. 13 Terminal box with standard module

The standard module is standard in three-phase
pumps with three speeds and forms connection
between supply terminals and motor.
The pumps with standard module must be connected
to the power supply via an external contactor.
For motor protection the contactor is to be connected
to the pump’s built-in thermal overload switch to
protect the pump against overheating at all three
speeds.

Standard module indicator lights

Description
Green

Red

Off

Off

The electricity supply has been switched off, or the
pump has been cut out by the thermal overload
switch.

On

Off

The electricity supply has been switched on.

On

On

The electricity supply has been switched on.
The direction of rotation is wrong.

Variable frequency drive operation
All 3 x 460 V, 3 x 575 V and 3-speed 3 x 208-230 V
pumps with standard module are suitable for variable
frequency drive (VFD) applications. Please note the
following:
• Even if the red indicator light is on, the pump is
operating normally.
• Pumps fitted with other modules than the standard
module must not be connected to a VFD.
• Depending on the VFD type, this may cause
increased acoustic noise from the motor.
Furthermore, it may cause the motor to be exposed
to detrimental voltage peaks.
• The motor must be protected against voltage peaks
higher than 650 V between the motor terminals.
Acoustic noise and detrimental voltage peaks can be
reduced by fitting an LC filter between the VFD and the
motor.

Pumps with protection module
The protection module is standard for single-phase
UPS pumps and available for 3 x 208-230 V UPS
pump models only as an option.
When fitted with a protection module, the pump can be
connected directly to the power supply switch as it will
be protected by the built-in overload protection.
The protection module incorporates two indicator
lights.

The indicator lights on pumps with standard module
show whether the pump is live, or whether the phase
sequence of three-phase pumps is wrong.

17

UP, UPS Series 200

7
Functions

Protection module indicator lights

Indicator lights

Description

Indicator lights
Description
Green

Red

Off

Off

On

Off

On

On

Off

On

The pump has been stopped. The electricity
supply has been switched off.
The pump is operating.
Three-phase pumps only:
The pump is operating, but the direction of
rotation is wrong.
The pump has been cut out by the thermal
overload switch.

Green

Red

Off

Off

On

On

Relay module indicator lights
The relay module indicator lights provides detailed
operating and fault indications.
All pumps with relay module incorporate a green and a
red indicator light. Functions, see table in Signal output
of relay module.

Signal output of relay module
The relay module has a signal output for external
operating or fault indication.
By means of the selector switch, the signal output can
be set to activation during operation or fault.
Operation: The output functions as operating
indication between terminals 2 and 3.
Fault: The output functions as fault indication
between terminals 1 and 3.

Off

On

Flashing

Off

Flashing

Fault

1 2 3
NC NO C

1 2 3
NC NO C

1 2 3
NC NO C

1 2 3
NC NO C

On

The pump has been
stopped. The electricity
supply has been switched
off, or a phase is missing.

The pump is operating.

On

Pumps with relay module
The relay module is available for UPS pumps as an
option for 1 x 115/230 V and 3 x 208-230 V units.
The module enables direct connection of the pump to
an external power supply switch. Furthermore, the
module has a signal output for external operating or
fault indication. By means of a selector switch the
output can be set to activation during operation or
fault.
The pump is connected directly to the power supply as
the pump incorporates overload protection at all three
speeds.
Note: Pumps with relay module must not be connected
to a variable frequency drive (VFD).
If the pump has been cut out by the thermal overload
switch, it will restart automatically when it has cooled
to normal temperature, provided the external on/off
contact is closed.
Note: If the thermal overload switch has cut out the
pump three times within a short time, the relay must be
reset manually by switching off the electricity supply.

Operation

Off

Note: Pumps with protection module must not be
connected to a variable frequency drive.

18

Signal output
set to

1 2 3
NC NO C

1 2 3
NC NO C

1 2 3
NC NO C

1 2 3
NC NO C

1 2 3
NC NO C

1 2 3
NC NO C

1 2 3
NC NO C

1 2 3
NC NO C

Only three-phase pumps:
The pump is operating, but
with wrong direction of
rotation.
The pump has been cut out
by the thermal overload
switch.

The pump has been
stopped by an external
on/off switch.
The pump is or has been
cut out by the thermal
overload switch, and it has
been stopped by an
external on/off switch.

Two pumps plumbed in parallel
Operating modes
Both pumps must be fitted with a relay module.
In addition to the signal functions, the signal output of
the relay module for two pumps in parallel can be used
for controlling the operating mode of pump 1 and 2.
It is possible to choose between three operating
modes:
1. Alternating operation. The pumps operate
alternately as duty and standby pump, respectively.
Changeover takes place every 24 hours. If the duty
pump is cut out due to a fault, the standby pump will
automatically start. During changeover both pumps
will be running for a short period to ensure a
low-noise changeover.
2. Standby operation. The pumps operate
continuously as duty and standby pump,
respectively. If the duty pump is cut out due to a
fault, the standby pump will automatically start at a
signal from the output of the duty pump. The
sequence can be changed to make the standby
pump operate as duty pump.
3. Single-pump operation. The pumps run
independently without communicating with each
other.

UP, UPS Series 200

8
Technical data

8. Technical data
Technical data, UPS
Model

Cast iron
product
number

Bronze
product number

96402694

96402699

Max. Hp
Speed 3

Ph

Voltage

115
1

96402695

UPS 32-40/4

96402696

96402697

96402698

96402708

96402700

96402701

230

0.33

96402702

208-230

3

96402703

460

575

96402713

115
1

96402709

UPS 32-80/2

96402710

96402711

96402712

96402730

96402714

96402715

230

0.50

96402716

208-230

3

96402717

460

575

96402739

115
1

96402733

UPS 32-160/2

96402736

96402737

96402738

96402740

96402741

230

0.75

96402742

96402743

208-230

3

460

575

Speed

I-MAX.
[Amps]

P-MAX.
[Watts]

Istart
[Amps]

3

1.08

120

2.10

2

1.04

100

2.02

1

0.95

85

1.85

3

0.54

120

1.00

2

0.52

100

0.96

1

0.47

85

0.87

3

0.56

115

1.60

2

0.26

75

0.74
0.69

1

0.24

65

3

0.28

115

0.82

2

0.13

75

0.38

▲

▲

▲

▲

3

0.22

115

0.66
0.30

2

0.10

75

▲

▲

▲

▲

3

2.66

280

7.10

2

2.50

260

6.67

1

2.50

250

6.67

3

1.34

280

3.80

2

1.26

260

3.29

1

1.26

250

3.29

3

1.10

280

5.00

2

0.72

235

3.93

1

0.58

195

3.16

3

0.55

280

2.80

2

0.36

235

1.96

▲

▲

▲

▲

3

0.44

280

2.20
1.60

2

0.29

235

▲

▲

▲

▲

3

5.80

625

14.60

2

5.80

600

14.60

1

5.50

555

13.84

3

2.90

625

6.70

2

2.90

600

6.70

1

2.75

555

6.35

3

1.96

600

9.30

2

1.25

430

5.93

1

1.12

380

5.31

3

0.98

600

4.70
3.02

2

0.63

430

▲

▲

▲

▲

3

0.78

600

3.76

2

0.50

430

2.40

▲

▲

▲

▲

▲All 3-phase, 460V and 575V pumps are 2-speed only.
Canada only

19

UP, UPS Series 200

8
Technical data

Model

Cast iron
product
number

Bronze
product number

Max. Hp
Speed 3

Ph

Voltage

96402748
96402753

115
1

96402749

UPS 40-40/4

96402750

96402751

96402752

96404948

96402754

96402755

230

0.33

96402756

208-230

3

96402757

460

575

96404953

115
1

96404949

UPS 40-80/4

96404950

96404951

96404952

96402762

96404954

96404955

230

0.50

96404956

208-230

3

96404957

460

575

96402767

115
1

96402763

UPS 40-80/2

96402764

96402765

96402766

▲

96402768

96402769

230

0.75

96402770

96402771

All 3-phase, 460V and 575V pumps are 2-speed only.
 Canada only

20

208-230

3

460

575

Speed

I-MAX.
[Amps]

P-MAX.
[Watts]

Istart
[Amps]

3

1.60

170

3.10

2

1.48

150

2.87

1

1.34

125

2.60

3

0.80

170

1.50

2

0.74

150

1.39

1

0.66

125

1.24

3

0.88

260

2.50

2

0.42

120

1.19

1

0.36

100

1.02

3

0.44

260

1.30
0.62

2

0.21

120

▲

▲

▲

▲

3

0.33

260

1.04
0.50

2

0.17

120

▲

▲

▲

▲

3

5.50

565

9.50

2

5.15

485

8.90

1

4.30

410

7.43

3

2.75

565

4.70

2

2.60

485

4.44

1

2.15

410

3.67

3

1.98

550

7.10

2

1.20

370

4.30

1

1.00

305

3.59

3

0.99

550

4.70

2

0.60

370

4.44

▲

▲

▲

▲

3

0.78

550

3.76
3.55

2

0.48

370

▲

▲

▲

▲

3

4.45

480

11.00

2

4.40

450

10.88

1

4.40

440

10.88

3

2.24

480

5.60

2

2.20

450

5.50

1

2.18

440

5.45

3

1.45

440

7.40

2

0.94

320

4.80

1

0.86

290

4.39

3

0.73

440

3.70

2

0.47

320

2.38

▲

▲

▲

▲

3

0.58

440

2.96

2

0.38

320

1.90

▲

▲

▲

▲

UP, UPS Series 200

Cast iron
product
number

Bronze
product number

96402782

96402787

Max. Hp
Speed 3

Ph

Voltage

115
1

96402783

UPS 40-160/2

96402784

96402785

96402786

96402797

96402798

96402788

96402789

230

0.75

96402790

208-230

3

96402791

460

575

96402804

1

96402805

230

208-230
1.50

UPS 40-240/2
96402799

96402801

96402814

96402807

3

96402809

460

575

96402819

115
1

96402815

UPS 50-40/4

96402816

96402817

96402818

96402820

96402821

230

0.33

96402822

96402823

208-230

3

460

575

Speed

I-MAX.
[Amps]

P-MAX.
[Watts]

Istart
[Amps]

3

8.40

890

18.60

2

7.45

760

16.50

1

6.95

690

15.39

3

4.20

890

9.30

2

3.75

760

8.30

1

3.45

690

7.64

3

2.50

800

12.40

2

1.75

570

8.68

1

1.55

500

7.69

3

1.25

800

6.20
4.36

2

0.88

570

▲

▲

▲

▲

3

1.00

800

4.96
3.50

2

0.70

570

▲

▲

▲

▲

3

6.20

1350

11.80

2

5.55

1200

10.56

1

5.15

1100

9.80

3

4.50

1440

23.80

2

3.25

1100

17.19

1

2.95

990

15.60

3

2.25

1440

11.60

2

1.63

1100

8.40

▲

▲

▲

▲

3

1.80

1440

9.28
6.72

2

1.30

1100

▲

▲

▲

▲

3

2.66

285

5.20

2

2.60

244

5.08

1

2.20

204

4.30

3

1.32

285

2.60

2

1.30

244

2.56

1

1.10

204

2.17

3

1.40

270

4.60

2

0.66

170

2.17

1

0.54

150

1.77

3

0.70

270

2.30

2

0.33

170

1.08

▲

▲

▲

▲

3

0.56

270

1.84

2

0.26

170

0.86

▲

▲

▲

▲

Technical data

Model

8

▲

All 3-phase, 460V and 575V pumps are 2-speed only.
 Canada only

21

UP, UPS Series 200

8
Technical data

Model

Cast iron
product
number

Bronze
product number

96404958

96404963

Max. Hp
Speed 3

Ph

Voltage

115
1

96404959

UPS 50-80/4

96404960

96404961

96404962

96402834

96404964

96404965

230

0.75

96404966

208-230

3

96404967

460

575

96402843

115
1

96402836

UPS 50-80/2

96402838

96402840

96402842

96411613

96402860

96402844

96402845

96402862

96402882

96402883

96402884

3

96402847

460

575

96411614

1

96402866

230

208-230

96402868

3

96402870

96402885

96402886

460

575

208-230

2.00

96402887

All 3-phase, 460V and 575V pumps are 2-speed only.
 Canada only

22

208-230

1.50
96402861

▲

0.75

96402846

UPS 50-160/2

UPS 50-240/2

230

3

460

575

Speed

I-MAX.
[Amps]

P-MAX.
[Watts]

Istart
[Amps]

3

7.55

720

13.20

2

6.85

620

11.98

1

5.15

480

9.00

3

3.80

720

6.50

2

3.40

620

5.82

1

2.60

480

4.45

3

2.44

640

8.50

2

1.44

450

5.02

1

1.24

390

4.32

3

1.22

640

4.30
2.54

2

0.72

450

▲

▲

▲

▲

3

0.98

640

3.44
2.00

2

0.58

450

▲

▲

▲

▲

3

5.85

630

14.60

2

5.80

610

14.48

1

5.70

600

14.23

3

2.95

630

7.30

2

2.90

610

7.18

1

2.85

600

7.05

3

1.92

610

9.30

2

1.20

440

5.81

1

1.08

400

5.23

3

0.96

610

4.70

2

0.60

440

2.94

▲

▲

▲

▲

3

0.77

610

3.76
2.40

2

0.48

440

▲

▲

▲

▲

3

5.80

1250

26.50

2

5.20

1100

23.76

1

4.85

1050

22.16

3

4.00

1300

22.80

2

3.00

1000

17.10

1

2.75

950

15.68

3

2.00

1300

11.40

2

1.50

1000

8.55

▲

▲

▲

▲

3

1.60

1300

9.12
6.84

2

1.20

1000

▲

▲

▲

▲

3

5.80

1700

26.50

2

3.95

1300

23.10

1

3.50

1150

20.47

3

2.65

1700

15.40

2

1.98

1300

11.51

▲

▲

▲

▲

3

2.12

1700

12.32

2

1.68

1300

9.21

▲

▲

▲

▲

UP, UPS Series 200

Cast iron
product
number

Bronze
product number

96654373

96654392

Max. Hp
Speed 3

Ph

Voltage

115
1

96654374

UPS 53-55/57

96654375

96654376

96654377

96654378

96654379

96654393

96654394

96654391

96402894

96402895

96402896

96402908

96402920

UPS 80-160/2

208-230

3

96654396

460

575

96654397

1

96654398

230

208-230
1.50

96654390

UPS 80-80/4

0.75

96654395

UPS 75-69

UPS 80-40/4

230

96402921

96402922

96654399

3

96654400

575

96402899

9
6402900

208-230

0.50

3

96402901

96402913

460

575

1.50

3

96402923

96402924

460

208-230

208-230

3.00

96402925

3

460

575

Speed

I-MAX.
[Amps]

P-MAX.
[Watts]

Istart
[Amps]

3

5.85

630

14.60

2

5.80

610

14.23

1

5.70

600

14.48

3

2.95

630

7.30

2

2.90

610

7.18

1

2.85

600

7.05

3

1.92

610

9.30

2

1.20

440

5.81

1

1.08

400

5.23

3

0.96

610

4.70
2.94

2

0.60

440

▲

▲

▲

▲

3

0.77

610

3.76

2

0.48

440

2.40

▲

▲

▲

▲

2

5.20

1100

23.76

1

4.85

1050

22.16

3

4.00

1300

22.80

2

3.00

1000

17.10

1

2.75

950

15.68

3

2.00

1300

11.40

2

1.50

1000

8.55

▲

▲

▲

▲

3

1.60

1300

9.12
6.84

2

1.20

1000

▲

▲

▲

▲

3

1.62

380

7.10

2

0.87

260

3.81

1

0.77

230

3.37

3

0.81

380

3.50
1.90

2

0.44

260

▲

▲

▲

▲

3

0.65

380

2.80
1.52

2

0.35

260

▲

▲

▲

▲

3

3.60

1050

11.80

2

2.08

660

6.82

1

1.72

550

5.64

3

6.35

2050

31.00

2

4.20

1550

20.50

1

4.05

1500

19.77

3

3.13

2050

15.40
10.17

2

2.10

1550

▲

▲

▲

▲

3

2.54

2050

12.32

2

1.68

1550

8.14

▲

▲

▲

▲

Technical data

Model

8

▲

All 3-phase, 460V and 575V pumps are 2-speed only.
 Canada only

23

UP, UPS Series 200

8
Technical data

Model

UPS 100-40/4

Cast iron
product
number

Bronze
product number

96402934

96402937

96402935

96402936

96402938

Max. Hp
Speed 3

Ph

Voltage

208-230

1.00

3

460

96401961

575

Speed

I-MAX.
[Amps]

P-MAX.
[Watts]

Istart
[Amps]

3

2.50

570

10.80

2

1.38

435

5.96

1

1.24

390

5.36

3

1.24

570

5.40
3.05

2

0.70

435

▲

▲

▲

▲

3

1.00

570

4.32

2

0.55

435

2.44

▲

▲

▲

▲

▲

All 3-phase, 460V and 575V pumps are 2-speed only.
 Canada only

Technical data, UP
Cast iron
product number

Bronze
product number

Hp

Ph

Voltage

I-MAX [Amps]

P-MAX [Watts]

UP 43-70

96439644

—

0.50

1

115/230

3.4/1.8

400

UP 43-110

96439643

—

0.75

1

115/230

4.9/2.5

570

UP 53-45

96633576

96633578

0.50

1

115/230

3.5/1.9

360

UP 53-46

96633591

96633592

0.75

1

115/230

3.9/2.1

420

Pump type

Curve conditions
The guidelines listed below, apply to the performance
curves in section 9. Curve charts and technical data:
1. Because of the danger of overheating, the pumps
must not be used at a flow below 0.1 x Q at best
efficiency point.
2. The bold parts of the curves show the
recommended performance range.
3. Test liquid: Airless water.
4. The curves apply to a liquid temperature
of 68 °F (20 ºC).
All curves show average values and should not be
used as guarantee curves. If a stated minimum
performance is required, individual measurements
must be made.

24

UP, UPS Series 200

9

UPS 32-40/4
1 ph, 115 V, 230 V, 60 Hz

Curve charts and technical data

9. Curve charts and technical data
UPS 32-40/4, 1 ph, 115 V, 230 V, 60 Hz
H [ft]
12

H [m]

2
1

10

3

3

8
2

6
4

1

2
0
0

10

0
P1 [hp] P1 [W]
150
0.2
100
0.1
50
0.0

2

20

30

4

6

40
8

50
10

60 Q [US GPM]
Q [m³/h]

12

60 Eta [%]
3
1

20
Eta

0

10

20

30

40

1 - 11 ft

Motor:

4-pole 0.33 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

35.9 lbs (16.3 kg)

Gross wt.:

43.4 lbs (19.7 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Net wt. bronze:

39.2 lbs (17.8 kg)

Gross wt. bronze:

46.7 lbs (21.2 kg)

Shipping volume bronze:

1.70 ft3 (0.048 m3)

40

2

0

9 - 52 gpm

Head range:

TM00 9510 0697

0

Flow range:

0
60 Q [US GPM]

50

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

D6

B5

D7

Dimensions
Model
UPS 32-40/4

[in]

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

11.00

5.50

5.31

5.56

3.00

3.00

3.19

2.69

9.50

12.24

1.44

2.56

3.14

4.63

0.50

1.81

2.25

279

140

135

141

76

76

81

68

241

311

37

65

80

117

13

46

57

[mm]

Product numbers

M12

Connections
Product number

Flange size

Voltage
[V]

Model type

UPS 32-40/4 (1 ph)

M

Cast Iron

Bronze

96402694

96402699

115

96402695

96402700

230

1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 15/26

Electrical data
Max amps
[A]

Speed

Start amps
[A]

P Max
[Watts]

115V

230V

115V

230V

3

1.08

0.54

120

2.10

1.00

2

1.04

0.52

100

2.02

0.96

1

0.95

0.47

85

1.85

0.87

25

UPS 32-40/4

Curve charts and technical data

UP, UPS Series 200

9

UPS 32-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

Flow range:

9 - 52 gpm

Head range:

1 - 11 ft

3

Motor:

4-pole 0.33 Hp

2
1

Max. liquid temp (Open):

+140 °F

H [ft]
12

H [m]

10

3

8
2

6
4

1

2
0
0

10

0
P1 [hp] P1 [W]
150
0.2
100
0.1
50
0.0

20

2

4

30

40

6

50

8

10

60 Q [US GPM]

12

Q [m³/h]
60 Eta [%]

3

40

2

1

20

Eta

0
0

10

20

30

40

0
60 Q [US GPM]

50

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

35.9 lbs (16.3 kg)

Gross wt.:

43.4 lbs (19.7 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Net wt. bronze:

39.2 lbs (17.8 kg)

Gross wt. bronze:

46.7 lbs (21.2 kg)

Shipping volume bronze:

1.70 ft3 (0.048 m3)

TM03 7904 5106

0

Max. liquid temp.:

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

D6

B5

D7

Dimensions
Model
UPS 32-40/4

[in]

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

11.00

5.50

5.31

5.56

3.00

3.00

3.19

2.69

9.50

12.24

1.44

2.56

3.14

4.63

0.50

1.81

2.25

279

140

135

141

76

76

81

68

241

311

37

65

80

117

13

46

57

[mm]

Product numbers

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402696

96402701

208-230

96402697

96402702

460

96402698

96402703

575 ★

Model type

UPS 32-40/4 (3 ph)

M

Flange size
1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 15/26

Electrical data
Max amps
[A]

Speed

26

208-230V

460V

575V ★

3

0.56

0.28

0.22

2

0.26

0.13

0.10

1

0.24

▲

▲

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]
208-230V

460V

575V ★

115

1.60

0.82

0.66

75

0.74

0.38

0.30

65

0.69

▲

▲

UP, UPS Series 200

9

UPS 32-80/2
1 ph, 115 V, 230 V, 60 Hz

H [ft]
25

H [m]

4
2

2

1

20

6

3

9 - 67 gpm

Head range:

1 - 25 ft

Motor:

2-pole 0.50 Hp

Max. liquid temp (Open):

+140 °F

15

Max. liquid temp.:

+248 °F

10

Min. liquid temp.:

+32 °F

5
0
0

10

0
P1 [hp] P1 [W]
300
0.4
0.3
200
0.2
100
0.1
0.0
0
0

2

20
4

30
6

40
8

50

10

60

12

70 Q [US GPM]
Q [m³/h]

14

1

3

2

40
20

Eta

10

20

30

40

50

60 Eta [%]

0
70 Q [US GPM]

60

Max. system pressure:

145 psi

Net wt:

35.9 lbs (16.3 kg)

Gross wt.:

41.1 lbs (20 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Net wt. bronze:

39.2 lbs (17.8 kg)

Gross wt. bronze:

47.4 lbs (21.5 kg)

Shipping volume bronze:

1.70 ft3 (0.048 m3)

TM00 9511 0697

0

Flow range:

Curve charts and technical data

UPS 32-80/2, 1 ph, 115 V, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

D6

B5

D7

Dimensions
Model
UPS 32-80/2

[in]

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

11.00

5.50

5.31

5.56

3.00

3.00

3.19

2.69

9.50

12.12

1.44

2.56

3.14

4.63

0.50

1.81

2.25

279

140

135

141

76

76

81

68

241

308

37

65

80

117

13

46

57

[mm]

Product numbers

M12

Connections
Product number

Model type
UPS 32-80/2
(1 ph)

M

Flange size

Voltage
[V]

Cast Iron

Bronze

96402708

96402713

115

96402709

96402714

230

1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 15/26

Electrical data
Max amps
[A]

Speed

Start amps
[A]

P Max
[Watts]

115V

230V

115V

230V

3

2.66

1.34

280

7.10

3.80

2

2.50

1.26

260

6.67

3.29

1

2.50

1.26

250

6.67

3.29

27

UPS 32-80/2

Curve charts and technical data

UP, UPS Series 200

9

UPS 32-80/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [ft]
25

H [m]

20

6
4
2

3
2
1

9 - 67 gpm

Head range:

1 - 25 ft

Motor:

2-pole 0.50 Hp

Max. liquid temp (Open):

+140 °F

15

Max. liquid temp.:

+248 °F

10

Min. liquid temp.:

+32 °F

5
0
0

10

0
P1 [hp] P1 [W]
300
0.4
0.3
200
0.2
100
0.1
0.0
0
0

20

2

4

30

40

6

8

50

10

60

12

70 Q [US GPM]
Q [m³/h]

14
3

2

40

1
Eta

10

20

30

40

50

60 Eta [%]
20

0
70 Q [US GPM]

60

Max. system pressure:

145 psi

Net wt:

35.9 lbs (16.3 kg)

Gross wt.:

41.1 lbs (20 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Net wt. bronze:

39.2 lbs (17.8 kg)

Gross wt. bronze:

47.4 lbs (21.5 kg)

Shipping volume bronze:

1.70 ft3 (0.048 m3)

TM00 9494 0697

0

Flow range:

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

D6

B5

D7

Dimensions
Model
[in]

UPS 32-80/2

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

11.00

5.50

5.31

5.56

3.00

3.00

3.19

2.69

9.50

12.12

1.44

2.56

3.14

4.63

0.50

1.81

2.25

279

140

135

141

76

76

81

68

241

308

37

65

80

117

13

46

57

[mm]

Product numbers

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402710

96402715

208-230

96402711

96402716

460

96402712

96402717

575 ★

Model type

UPS 32-80/2
(3 ph)

M

Flange size
1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 15/26

Electrical data
Max amps
[A]

Speed

28

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

575V ★

3

1.10

0.55

0.44

280

5.00

2.80

2.20

2

0.72

0.36

0.29

235

3.93

1.96

1.60

1

0.58

▲

▲

195

3.16

▲

▲

UP, UPS Series 200

9

UPS 32-160/2
1 ph, 115 V, 230 V, 60 Hz

H [ft]
50

H [m]
14
12
10
8
6
4
2
0

3

1 2

40

Flow range:

9 - 76 gpm

Head range:

1 - 45 ft

Motor:

2-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

30

Max. liquid temp.:

+248 °F

20

Min. liquid temp.:

+32 °F

10
0

0
P1 [hp] P1 [W]
800
1.0
600
400
0.5
200
0.0
0
0

10

20

2

4

30
6

40
8

50

60

70

80 Q [US GPM]

10 12 14 16 18 Q [m³/h]

3

2

1

Eta

10

20

30

40

50

60

70

80 Eta [%]
60
40
20
0
80 Q [US GPM]

145 psi

Net wt:

37.0 lbs (16.8 kg)

Gross wt.:

45.2 lbs (20.5 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Net wt. bronze:

37.7 lbs (17.1 kg)

Gross wt. bronze:

45.9 lbs (20.8 kg)

Shipping volume bronze:

1.70 ft3 (0.048 m3)

TTM00 9512 0697

0

Max. system pressure:

Curve charts and technical data

UPS 32-160/2, 1 ph, 115 V, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

B5

D6
D7

Dimensions
Model
UPS 32-160/2

[in]

L1

L3

B1

B2

B4

B5

B7

H1

13.50

5.50

5.31

5.56

3.00

3.00

3.19

2.69

343

140

135

141

76

76

81

68

[mm]

Product numbers

H3

9.50 12.16
241

309

D1

D2

D3

D4

D5

D6

D7

1.44

2.50

3.42

4.63

0.50

2.06

2.56

37

64

87

117

13

52

65

M

M12

Connections
Product number

Model type
UPS 32-160/2
(1 ph)

H2

Flange size

Voltage
[V]

Cast Iron

Bronze

96402730

96402739

115

96402733

96402740

230

1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

P Max
[Watts]

Start amps
[A]

115V

230V

115V

230V

3

5.80

2.90

625

14.60

6.70

2

5.80

2.90

600

14.60

6.70

1

5.50

2.75

555

13.84

6.35

29

UPS 32-160/2

Curve charts and technical data

UP, UPS Series 200

9

UPS 32-160/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [ft]
50

H [m]
14
12
10
8
6
4
2
0

3

40

1

2

Flow range:

9 - 76 gpm

Head range:

1 - 45 ft

Motor:

2-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

30

Max. liquid temp.:

+248 °F

20

Min. liquid temp.:

+32 °F

10
0
0

0
P1 [hp] P1 [W]
800
1.0
600
400
0.5
200
0.0
0
0

10

20

2

4

30
6

40

50

60

70

80 Q [US GPM]

10 12 14 16 18 Q [m³/h]

8

80 Eta [%]
60
2
40
Eta
20
0
70 80 Q [US GPM]

1

10

20

30

40

50

60

145 psi

Net wt:

36.8 lbs (16.7 kg)

Gross wt.:

44.8 lbs (20.3 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Net wt. bronze:

41.2 lbs (18.7 kg)

Gross wt. bronze:

49.4 lbs (22.4 kg)

Shipping volume bronze:

1.70 ft3 (0.048 m3)

TM00 9495 0697

3

Max. system pressure:

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

B5

D6
D7

Dimensions
Model
UPS 32-160/2

[in]

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

13.50

5.50

5.31

5.56

3.00

3.00

3.19

2.69

9.50

12.16

1.44

2.50

3.42

4.63

0.50

2.06

2.56

343

140

135

141

76

76

81

68

241

309

37

64

87

117

13

52

65

[mm]

Product numbers

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402736

96402741

208-230

96402737

96402742

460

96402738

96402743

575 ★

Model type

UPS 32-160/2
(3 ph)

M

Flange size
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

30

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

575V ★

3

1.96

0.98

0.78

600

9.30

4.70

3.76

2

1.25

0.63

0.50

430

5.93

3.02

2.40

1

1.12

▲

▲

380

5.31

▲

▲

UP, UPS Series 200

9

UPS 40-40/4
1 ph, 115 V, 230 V, 60 Hz

H [ft]
12

H [m]

3
2
1

10

3

8
2

6
4

1

2
0
0

10 20 30 40 50 60 70 80 90 Q [US GPM]

0
P1 [hp] P1 [W]
300
0.4
0.3
200
0.2
100
0.1
0.0
0
0

2

4

6

8 10 12 14 16 18 20 Q [m³/h]
60 Eta [%]
2

1

40

3

20

Eta

0
10 20 30 40 50 60 70 80 90 Q [US GPM]

13 - 85 gpm

Head range:

1 - 11 ft

Motor:

4-pole 0.33 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

37.9 lbs (17.2 kg)

Gross wt.:

46.1 lbs (20.9 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Net wt. bronze:

42.3 lbs (19.2 kg)

Gross wt. bronze:

50.5 lbs (22.9 kg)

Shipping volume bronze:

1.70 ft3 (0.048 m3)

TM00 9513 0697

0

Flow range:

Curve charts and technical data

UPS 40-40/4, 1 ph, 115 V, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

D6

B5

D7

Dimensions
Model
UPS 40-40/4

[in]

L1

L3

B1

B2

B4

B5

B7

H1

H2

13.50

6.75

5.31

5.56

3.00

3.00

4.75

2.69

9.69

343

171

135

141

76

76

121

68

246

[mm]

Product numbers

D1

315

41

D2

D3

D4

D5

D6

D7

2.88

3.42

5.00

0.50

2.06

2.56

73

87

127

13

52

65

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402748

96402753

115

96402749

96402754

230

Model type

UPS 40-40/4 (1 ph)

H3

12.40 1.63

Flange size
1.50" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

Start amps
[A]

P Max
[Watts]

115V

230V

115V

230V

3

1.60

0.80

170

3.10

1.50

2

1.48

0.74

150

2.87

1.39

1

1.34

0.66

125

2.60

1.24

31

UPS 40-40/4

Curve charts and technical data

UP, UPS Series 200

9

UPS 40-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [ft]
12

H [m]

3

10

3

1 2

8
2
1

13 - 85 gpm

Head range:

1 - 11 ft

Motor:

4-pole 0.33 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

6

Min. liquid temp.:

+32 °F

4

Max. system pressure:

145 psi

2

Net wt:

37.7 lbs (17.1 kg)

0
0

10 20 30 40 50 60 70 80 90 Q [US GPM]

0
P1 [hp] P1 [W]
300
0.4
0.3
200
0.2
100
0.1
0.0
0
0

2

4

6

10 12 14 16 18 20 Q [m³/h]

8

60 Eta [%]
3
1

45.9 lbs (20.8 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Net wt. bronze:

42.1 lbs (19.1 kg)

Gross wt. bronze:

50.3 lbs (22.8 kg)

Shipping volume bronze:

1.70 ft3 (0.048 m3)

40
20

2

Gross wt.:

TM00 9496 0697

0

Flow range:

Eta

0
10 20 30 40 50 60 70 80 90 Q [US GPM]

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

B5

D6
D7

Dimensions
Model
[in]

UPS 40-40/4

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

13.50

6.75

5.31

5.56

3.00

3.00

4.75

2.69

9.69

12.40

1.63

2.88

3.42

5.00

0.50

2.06

2.56

343

171

135

141

76

76

121

68

246

315

41

73

87

127

13

52

65

[mm]

Product numbers

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402750

96402755

208-230

96402751

96402756

460

96402752

96402757

575 ★

Model type

UPS 40-40/4
(3 ph)

M

Flange size
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

32

208-230V

460V

575V ★

3

0.88

0.44

0.33

2

0.42

0.21

0.17

1

0.36

▲

▲

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]
208-230V

460V

575V ★

260

2.50

1.30

1.04

120

1.19

0.62

0.50

100

1.02

▲

▲

UP, UPS Series 200

9

UPS 40-80/4
1 ph, 115 V, 230 V, 60 Hz

H [ft]
25

H [m]
7
6
5
4
3
2
1
0

3
2
1

20

Flow range:

13 - 120 gpm

Head range:

1 - 25 ft

Motor:

4-pole 0.50 Hp

Max. liquid temp (Open):

+140 °F

15

Max. liquid temp.:

+248 °F

10

Min. liquid temp.:

+32 °F

5
0
20

0
P1 [hp] P1 [W]
600
0.8
0.6
400
0.4
200
0.2
0.0
0
0

5

40

60

10

80

15

100

20

120

25
2

140 Q [US GPM]
Q [m³/h]

30

60 Eta [%]

3

40

1

20

Eta

20

40

60

80

100

0
140 Q [US GPM]

120

145 psi

Net wt:

57.8 lbs (26.2 kg)

Gross wt.:

70.1 lbs (31.8 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

62.2 lbs (28.2 kg)

Gross wt. bronze:

74.5 lbs (33.8 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9514 2297

0

Max. system pressure:

Curve charts and technical data

UPS 40-80/4, 1 ph, 115 V, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

D5

M
B4

NPT 1/4

TM02 0729 5100

L3

D4

L1

D1

D6

B5

D7

Dimensions
Model
UPS 40-80/4

L1

L3

13.50 6.75

[in]

343

[mm]

B1

B2

B4

B5

B7

H1

5.75

6.68

3.94

3.94

4.75

3.00

146

170

100

100

121

76

171

Product numbers

H3

D1

9.00 12.01 1.69
229

305

43

D2

D3

D4

D5

D6

D7

2.88

3.42

5.00

0.50

2.06

2.56

73

87

127

13

52

65

M

M12

Connections
Product number

Model type
UPS 40-80/4
(1 ph)

H2

Flange size

Voltage
[V]

Cast Iron

Bronze

96404948

96404953

115

96404949

96404954

230

1.50" non ANSI 2 bolt w/ (2) 1/2" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

Start amps
[A]

P Max
[Watts]

115V

230V

115V

230V

3

5.50

2.75

565

9.50

4.70

2

5.15

2.60

485

8.90

4.44

1

4.30

2.15

410

7.43

3.67

33

UPS 40-80/4

Curve charts and technical data

UP, UPS Series 200

9

UPS 40-80/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [ft]
25

H [m]
7
6
5
4
3
2
1
0

3
2

20

1

15
10
5
0
20

0
P1 [hp] P1 [W]
600
0.8
0.6
400
0.4
200
0.2
0.0
0
0

5

40

60

10

80

15

100

20

120

30
3

2
1

20

40

60

80

100

4-pole 0.50 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

47.6 lbs (21.6 kg)
60.0 lbs (27.2 kg)
2.90 ft3 (0.082 m3)

Net wt. bronze:

52.0 lbs (23.6 kg)

60 Eta [%]

Gross wt. bronze:

64.4 lbs (29.2 kg)

40

Shipping volume bronze:

2.90 ft3 (0.082 m3)

Q [m³/h]

0
140 Q [US GPM]

120

Motor:

Shipping volume:

20
Eta

1 - 25 ft

Gross wt.:

140 Q [US GPM]

25

13 - 120 gpm

Head range:

TM00 9498 0307

0

Flow range:

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

D5

M
B4

NPT 1/4

B5

TM02 0729 5100

L3

D4

L1

D1

D6
D7

Dimensions
Model

L1
[in]

UPS 40-80/4

[mm]

L3

13.50 6.75
343

171

B1

B2

B4

B5

B7

H1

5.75

6.68

3.94

3.94

4.75

3.00

146

170

100

100

121

76

Product numbers

H3

D1

229

305

43

D2

D3

D4

D5

D6

D7

2.88

3.42

5.00

0.50

2.06

2.56

73

87

127

13

52

65

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402750

96402755

208-230

96402751

96402756

460

96402752

96402757

575 ★

Model type

UPS 40-80/4
(3 ph)

H2

9.00 12.01 1.69

Flange size
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

34

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

575V ★

3

1.98

0.99

0.78

550

7.10

4.70

3.76

2

1.20

0.60

0.48

370

4.30

4.44

3.55

1

1.00

▲

▲

305

3.59

▲

▲

UP, UPS Series 200

9

UPS 40-80/2
1 ph, 115 V, 230 V, 60 Hz

H [m]
8

Flow range:

13 - 105 gpm

Head range:

1 - 30 ft

Motor:

2-pole 0.75 Hp

20

Max. liquid temp (Open):

+140 °F

15

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

H [ft]
30
25

6
4

1

2

3

10
2

5
0
0

20

0
P1 [hp] P1 [W]
600
0.8
0.6
400
0.4
200
0.2
0.0
0
0

5

40

60

10

80

15

100
20

40

60

80

1.70 ft3 (0.048 m3)

Net wt. bronze:

42.8 lbs (19.4 kg)

60 Eta [%]

Gross wt. bronze:

50.9 lbs (23.1 kg)

40

Shipping volume bronze:

1.70 ft3 (0.048 m3)

20

Eta

20

46.5 lbs (21.1 kg)

Shipping volume:

Q [m³/h]

3

2

1

0
120 Q [US GPM]

100

38.4 lbs (17.4 kg)

Gross wt.:

120 Q [US GPM]
25

145 psi

Net wt:

TM00 9515 0307

0

Max. system pressure:

Curve charts and technical data

UPS 40-80/2, 1 ph, 115 V, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

B5

D6
D7

Dimensions
L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

13.50

6.75

5.31

5.56

3.00

3.00

3.13

2.69

9.63

12.36

1.69

2.88

3.42

5.00

0.50

2.06

2.56

343

171

135

141

76

76

79

68

244

314

43

73

87

127

13

52

65

Model
UPS 40-80/2

[in]
[mm]

Product numbers

M12

Connections
Product number

Model type
UPS 40-80/2
(1 ph)

M

Flange size

Voltage
[V]

Cast Iron

Bronze

96402762

96402767

115

96402763

96402768

230

1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

P Max
[Watts]

Start amps
[A]

115V

230V

115V

230V

3

4.45

2.24

480

11.00

5.60

2

4.40

2.20

450

10.88

5.50

1

4.40

2.18

440

10.88

5.45

35

UPS 40-80/2

Curve charts and technical data

UP, UPS Series 200

9

UPS 40-80/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [ft]
30

H [m]
8

25
20

6

3
2
1

15

4

10
2

5
0
0

20

40

0
P1 [hp] P1 [W]
600
0.8
0.6
400
0.4
200
0.2
0.0
0
0

5

60

10

80

15

100
20

120 Q [US GPM]
Q [m³/h]

25

60 Eta [%]
40

3
2

1

20

Eta

20

40

60

80

0
120 Q [US GPM]

100

13 - 105 gpm

Head range:

1 - 30 ft

Motor:

2-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

38.4 lbs (17.4 kg)

Gross wt.:

46.5 lbs (21.1 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Net wt. bronze:

42.8 lbs (19.4 kg)

Gross wt. bronze:

50.9 lbs (23.1 kg)

Shipping volume bronze:

1.70 ft3 (0.048 m3)

TM00 9497 0697

0

Flow range:

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

B5

D6
D7

Dimensions
L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

13.50

6.75

5.31

5.56

3.00

3.00

3.13

2.69

9.63

12.36

1.69

2.88

3.42

5.00

0.50

2.06

2.56

343

171

135

141

76

76

79

68

244

314

43

73

87

127

13

52

65

Model
[in]

UPS 40-80/2

[mm]

Product numbers

M12

Connections
Product number

Flange size

Voltage
[V]

Model type

UPS 40-80/2
(3 ph)

M

Cast Iron

Bronze

96402764

96402769

96402765

96402770

460

96402766

96402771

575 ★

1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

208-230

Electrical data
Max amps
[A]

Speed

36

208-230V

460V

575V ★

3

1.45

0.73

0.58

2

0.94

0.47

0.38

1

0.86

▲

▲

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]
208-230V

460V

575V ★

440

7.40

3.70

2.96

320

4.80

2.38

1.90

290

4.39

▲

▲

UP, UPS Series 200

9

UPS 40-160/2
1 ph, 115 V, 230 V, 60 Hz

H [ft]
50

H [m]
14
12
10
8
6
4
2
0

40

2

3

1

Flow range:

13 - 110 gpm

Head range:

1 - 46 ft

Motor:

2-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

30

Max. liquid temp.:

+248 °F

20

Min. liquid temp.:

+32 °F

10
0
20

0
P1 [hp] P1 [W]
1000
750
1.0
500
0.5
250
0.0
0
0

5

40

60

10

80

100

15

20

120 Q [US GPM]

1
Eta

40

60

80

80 Eta [%]
60
40
20
0
120 Q [US GPM]
3

2

20

Q [m³/h]

25

100

145 psi

Net wt:

43.2 lbs (19.6 kg)

Gross wt.:

55.6 lbs (25.2 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

47.6 lbs (21.6 kg)

Gross wt. bronze:

60 lbs (27.2 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9516 0307

0

Max. system pressure:

Curve charts and technical data

UPS 40-160/2, 1 ph, 115 V, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

D5

M
B4

NPT 1/4

B5

TM02 0729 5100

L3

D4

L1

D1

D6
D7

Dimensions
Model
UPS 40-160/2

[in]
[mm]

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

11.50

5.75

5.75

6.68

3.94

3.94

3.19

2.31

9.00

11.69

1.69

2.88

3.42

5.00

0.50

2.06

2.56

292

146

146

170

100

100

81

59

229

297

43

73

87

127

13

52

65

Product numbers

M12

Connections
Product number

Model type
UPS 40-160/2
(1 ph)

M

Flange size

Voltage
[V]

Cast Iron

Bronze

96402782

96402787

115

96402783

96402788

230

1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

P Max
[Watts]

Start amps
[A]

115V

230V

115V

230V

3

8.40

4.20

890

18.60

9.30

2

7.45

3.75

760

16.50

8.30

1

6.95

3.45

690

15.39

7.64

37

UPS 40-160/2

Curve charts and technical data

UP, UPS Series 200

9

UPS 40-160/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [m]
14
12
10
8
6
4
2
0

H [ft]
50
3

40

2
1

Flow range:

13 - 110 gpm

Head range:

1 - 46 ft

Motor:

2-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

30

Max. liquid temp.:

+248 °F

20

Min. liquid temp.:

+32 °F

10
0
0

20

40

0
P1 [hp] P1 [W]
1000
750
1.0
500
0.5
250
0.0
0
0

5

60

10

80

15

100
20

120 Q [US GPM]
Q [m³/h]

25

80 Eta [%]
60
2
40
Eta
20
0
100 120 Q [US GPM]

1

20

40

60

80

145 psi

Net wt:

43.2 lbs (19.6 kg)

Gross wt.:

55.6 lbs (25.2 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

47.6 lbs (21.6 kg)

Gross wt. bronze:

60 lbs (27.2 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9499 0307

3

Max. system pressure:

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

B5

D6
D7

Dimensions
Model
UPS 40-160/2

[in]
[mm]

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

11.50

5.75

5.75

6.68

3.94

3.94

3.19

2.31

9.00

11.69

1.69

2.88

3.42

5.00

0.50

2.06

2.56

292

146

146

170

100

100

81

59

229

297

43

73

87

127

13

52

65

Product numbers

M12

Connections
Product number

Flange size

Voltage
[V]

Model type

UPS 40-160/2
(3 ph)

M

Cast Iron

Bronze

96402784

96402789

208-230

96402785

96402790

460

96402786

96402791

575 ★

1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

38

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

575V ★

3

2.50

1.25

1.00

800

12.40

6.20

4.96

2

1.75

0.88

0.70

570

8.68

4.36

3.50

1

1.55

▲

▲

500

7.69

▲

▲

UP, UPS Series 200

9

UPS 40-240/2
1 ph, 230 V, 60 Hz

H [m]

H [ft]
60
50

15

1

3

2

40
10

30
20

5

10
0
0

20

0
P1 [hp] P1 [W]
2.0 1500
1.5 1000
1.0
500
0.5
0.0
0
0

5

40

60

10

80

15

100

20

120

25

30

40
20

Eta

20

40

60

80

100

Q [m³/h]
60 Eta [%]

3

2

1

140 Q [US GPM]

120

0
140 Q [US GPM]

13 - 130 gpm

Head range:

1 - 62 ft

Motor:

2-pole 1.5 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

54.0 lbs (24.5 kg)

Gross wt.:

66.4 lbs (30.1 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

58.4 lbs (26.5 kg)

Gross wt. bronze:

70.8 lbs 32.1 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9517 0307

0

Flow range:

Curve charts and technical data

UPS 40-240/2, 1 ph, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

D5

M
B4

NPT 1/4

B5

TM02 0729 5100

L3

D4

L1

D1

D6
D7

Dimensions
Model
UPS 40-240/2

L1

L3

13.50 3.75

[in]
[mm]

343

95

B1

B2

B4

B5

B7

H1

5.75

6.68

4.00

4.00

3.19

2.69

146

170

102

102

81

68

Product numbers

H3

D1

11.06 13.96 1.69
281

355

43

D2

D3

D4

D5

D6

D7

2.88

3.42

5.00

0.50

2.06

2.56

73

87

127

13

52

65

M

M12

Connections
Product number

Model type
UPS 40-240/2
(1 ph)

H2

Cast Iron

Bronze

96402797

96402804

Voltage
[V]

Flange size
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

230

Electrical data
Speed

Max amps
[A]

P Max
[Watts]

230V
3

Start amps
[A]
230V

6.20

1350

11.80

2

5.55

1200

10.56

1

5.15

1100

9.80

39

UPS 40-240/2

Curve charts and technical data

UP, UPS Series 200

9

UPS 40-240/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

20
15
10
5
0

H [ft]
70
60
50
40
30
20
10
0
0

3
1

2

20

0
P1 [hp] P1 [W]
2.0 1500
1.5 1000
1.0
500
0.5
0.0
0
0

40

5

60

10

80

15

100

20

120

25

140 Q [US GPM]
30
3

1

2

40

60

80

100

60 Eta [%]
40

Eta

20

Q [m³/h]

20

0
140 Q [US GPM]

120

Flow range:

13 - 130 gpm

Head range:

1 - 62 ft

Motor:

2-pole 1.5 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

47.2 lbs (21.4 kg)

Gross wt.:

59.5 lbs (27.0 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

51.6 lbs (23.4 kg)

Gross wt. bronze:

63.9 lbs (29.0 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9500 0307

H [m]

Note: ETA is calculated as wire-to-water efficiency.

H1

D2

B7

B

2

D3

H3
H2

B1

L3

TM02 0729 5100

D4

L1

D1

D5

M
B4

NPT 1/4

B5

D6
D7

Dimensions
Model

L1

UPS 40-240/2

[in]
[mm]

L3

13.50 3.75
343

95

B1

B2

B4

B5

B7

H1

5.75

6.68

4.00

4.00

3.19

2.69

146

170

102

102

81

68

Product numbers

H3

D1

281

355

43

D2

D3

D4

D5

D6

D7

2.88

3.42

5.00

0.50

2.06

2.56

73

87

127

13

52

65

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402798

96402805

208-230

96402799

96402807

460

96402801

96402809

575 ★

Model type

UPS 40-240/2
(3 ph)

H2

11.06 13.96 1.69

Flange size
1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

Electrical data
Max amps
[A]

Speed

40

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

3

4.50

2.25

1.80

1440

23.80

11.60

575V ★
9.28

2

3.25

1.63

1.30

1100

17.19

8.40

6.72

1

2.95

▲

▲

990

15.6

▲

▲

UP, UPS Series 200

9

UPS 50-40/4
1 ph, 115 V, 230 V, 60 Hz

4
3
2
1
0

2

3

20

0
P1 [hp] P1 [W]
300
0.4
0.3
200
0.2
100
0.1
0.0
0
0

40

5

60

10

80

15

100

20

120

140 Q [US GPM]

25

Q [m³/h]

30

60 Eta [%]

3

2

40

1

20

Eta

20

40

60

80

100

120

0
140 Q [US GPM]

Flow range:

20 - 125 gpm

Head range:

1 - 12 ft

Motor:

4-pole 0.33 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

43.7 lbs (19.8 kg)

Gross wt.:

51.8 lbs (23.5 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

53.6 lbs (24.3 kg)

Gross wt. bronze:

61.7 lbs (28.0 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9518 0307

H [ft]
14
12
10 1
8
6
4
2
0
0

H [m]

Curve charts and technical data

UPS 50-40/4, 1 ph, 115 V, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

L3

TM02 0730 5100

L1

D6
D7

D1

D5

M
NPT 1/4

B4

D2

B5

Dimensions
Model
UPS 50-40/4

L1

L3

14.00 7.00

[in]

356

[mm]

B1

B2

B4

B5

B7

5.31

5.56

3.56

3.00

4.75

135

141

90

76

121

178

H1

Product numbers

H3

D1

3.25 10.13 13.08 2.13
83

257

332

54

D2

D3

D4

D5

D6

D7

3.44

4.05

5.25

0.55

2.50

3.06

87

103

133

14

64

78

M

M12

Connections
Product number

Model type
UPS 50-40/4
(1 ph)

H2

Flange size

Voltage
[V]

Cast Iron

Bronze

96402814

96402819

115

96402815

96402820

230

2" non ANSI 4 bolt w/ (4) 0.56" dia. holes

Flange type
GF 50

Electrical data
Max amps
[A]

Speed

Start amps
[A]

P Max
[Watts]

115V

230V

115V

230V

3

2.66

1.32

285

5.20

2.60

2

2.60

1.30

244

5.08

2.56

1

2.20

1.10

204

4.30

2.17

41

UPS 50-40/4

Curve charts and technical data

UP, UPS Series 200

9

UPS 50-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

4
3
2
1
0

0
P1 [hp] P1 [W]
300
0.4
0.3
200
0.2
100
0.1
0.0
0
0

40

5

60

10

80

15

100

20

120

25

140 Q [US GPM]
30

60 Eta [%]

3

40

2
1

20
Eta

20

40

60

80

Q [m³/h]

100

120

0
140 Q [US GPM]

Flow range:

20 - 125 gpm

Head range:

1 - 12 ft

Motor:

4-pole 0.33 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

43.7 lbs (19.8 kg)

Gross wt.:

51.8 lbs (23.5 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

53.6 lbs (24.3 kg)

Gross wt. bronze:

61.7 lbs (28.0 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9501 0307

H [ft]
14
3
12
10 1 2
8
6
4
2
0
0
20

H [m]

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

L3

TM02 0730 5100

L1

D6
D7

D1

D5

M
NPT 1/4

B4

D2

B5

Dimensions
Model

L1
[in]

UPS 50-40/4

[mm]

L3

14.00 7.00
356

178

B1

B2

B4

B5

B7

5.31

5.56

3.56

3.00

4.75

135

141

90

76

121

H1

H3

D1

3.25 10.13 13.08 2.13
83

Product numbers

257

332

54

D2

D3

D4

D5

D6

D7

3.44

4.05

5.25

0.55

2.50

3.06

87

103

133

14

64

78

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402816

96402821

208-230

96402817

96402822

460

96402818

96402823

575 ★

Model type

UPS 50-40/4
(3 ph)

H2

Flange size
1" non ANSI 4 bolt w/ (4) 0.56" dia. holes

Flange type
GF 50

Electrical data
Max amps
[A]

Speed

42

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

575V ★

3

1.40

0.70

0.56

270

4.60

2.30

1.84

2

0.66

0.33

0.26

170

2.17

1.08

0.86

1

0.54

▲

▲

150

1.77

▲

▲

UP, UPS Series 200

9

UPS 50-80/4
1 ph, 115 V, 230 V, 60 Hz

H [ft]
25

H [m]
7
6
5
4
3
2
1
0

3

20

2
1

15
10
5
0

0
P1 [hp] P1 [W]
1000
800
1.0
600
400
0.5
200
0.0
0
0

20 40 60 80 100 120 140 160 180 Q [US GPM]
5

10

15

20

25

30

35

40

Q [m³/h]

50 Eta [%]
40
3
2
30
1
20
Eta
10
0
20 40 60 80 100 120 140 160 180 Q [US GPM]

20 - 160 gpm

Head range:

1 - 24 ft

Motor:

4-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

60.2 lbs (27.3 kg)

Gross wt.:

72.5 lbs (32.9 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

66.8 lbs (30.3 kg)

Gross wt. bronze:

79.1 lbs (35.9 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9519 0307

0

Flow range:

Curve charts and technical data

UPS 50-80/4, 1 ph, 115 V, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

D5

M

TM02 0730 5100

L3

L1

D6
D7

D1

NPT 1/4

B4

D2

B5

Dimensions
Model
UPS 50-80/4

[in]

L1

L3

B1

B2

B4

B5

B7

H1

11.50

7.00

5.75

6.68

4.38

3.94

4.75

3.25

292

178

146

170

111

100

121

83

[mm]

Product numbers

H3

10.88 14.23
276

361

D1

D2

D3

D4

D5

D6

D7

2.13

3.44

3.44

5.25

0.55

2.50

3.06

54

87

87

133

14

64

78

M

M12

Connections
Product number

Model type
UPS 50-80/4
(1 ph)

H2

Flange size

Voltage
[V]

Cast Iron

Bronze

96404958

96404963

115

96404959

96404964

230

2" non ANSI 4 bolt w/ (4) 0.56" dia. holes

Flange type
GF 50

Electrical data
Max amps
[A]

Speed

Start amps
[A]

P Max
[Watts]

115V

230V

3

7.55

3.80

115V

230V

720

13.20

6.50

2

6.85

1

5.15

3.40

620

11.98

5.82

2.60

480

9.00

4.45

43

UPS 50-80/4

Curve charts and technical data

UP, UPS Series 200

9

UPS 50-80/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [ft]
25

H [m]
7
6
5
4
3
2
1
0

20

3
2

1

Flow range:

20 - 160 gpm

Head range:

1 - 24 ft

Motor:

4-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

15

Max. liquid temp.:

+248 °F

10

Min. liquid temp.:

+32 °F

5
0
20 40 60 80 100 120 140 160 180 Q [US GPM]

0
P1 [hp] P1 [W]
1000
800
1.0
600
400
0.5
200
0.0
0
0

5

10

15

20

25

30

35

40

Q [m³/h]

50 Eta [%]
40
3
30
2
20
1
10
Eta
0
20 40 60 80 100 120 140 160 180 Q [US GPM]

145 psi

Net wt:

59.5 lbs (27.0 kg)

Gross wt.:

71.9 lbs (32.6 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

66.8 lbs (30.3 kg)

Gross wt. bronze:

79.1 lbs (35.9 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9502 0307

0

Max. system pressure:

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

TM02 0730 5100

L3

L1

D6
D7

D1

D5

M
NPT 1/4

B4

D2

B5

Dimensions
Model
[in]

UPS 50-80/4

L1

L3

B1

B2

B4

B5

B7

H1

11.50

7.00

5.75

6.68

4.38

3.94

4.75

3.25

292

178

146

170

111

100

121

83

[mm]

H2

10.88 14.23

Product numbers

276

361

D1

D2

D3

D4

D5

D6

D7

2.13

3.44

3.44

5.25

0.55

2.50

3.06

54

87

87

133

14

64

78

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96404960

96404965

208-230

96404961

96404966

460

96404962

96404967

575 ★

Model type

UPS 50-80/4
(3 ph)

H3

Flange size
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes

Flange type
GF 50

Electrical data
Max amps
[A]

Speed

44

208-230V

460V

575V ★

3

2.44

1.22

0.98

2

1.44

0.72

0.58

1

1.24

▲

▲

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]
208-230V

460V

575V ★

640

8.50

4.30

3.44

450

5.02

2.54

2.00

390

4.32

▲

▲

UP, UPS Series 200

9

UPS 50-80/2
1 ph, 115 V, 230 V, 60 Hz

H [ft]
35
30
25
20
15
10
5
0
0

10
8
6
4
2
0

3
2
1

20

0
P1 [hp] P1 [W]
800
1.0
600
400
0.5
200
0.0
0
0

5

20

40

60

10

80 100 120 140 160 Q [US GPM]

15

40

60

20

25

30

Q [m³/h]

35

80 Eta [%]
60
3
2
40
1
20
Eta
0
80 100 120 140 160 Q [US GPM]

Flow range:

20 - 150 gpm

Head range:

1 - 30 ft

Motor:

2-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

46.7 lbs (21.2 kg)

Gross wt.:

54.2 lbs (24.6 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

52.2 lbs (27.3 kg)

Gross wt. bronze:

59.7 lbs (27.1 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9520 0697

H [m]

Curve charts and technical data

UPS 50-80/2, 1 ph, 115 V, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

L3

TM02 0730 5100

L1

D6
D7

D1

D5

M
NPT 1/4

B4

D2

B5

Dimensions
Model
UPS 50-80/2

L1

L3

B1

B2

B4

B5

B7

H1

[in]

11.5

7.00

5.31

5.56

3.75

3.00

4.75

3.00

[mm]

292

178

135

141

95

76

121

76

Product numbers

H3

D1

9.88 12.86 2.13
251

327

54

D2

D3

D4

D5

D6

D7

3.44

4.06

5.25

0.55

2.50

3.06

87

103

133

14

64

78

M

M12

Connections
Product number

Model type
UPS 50-80/2
(1 ph)

H2

Flange size

Voltage
[V]

Cast Iron

Bronze

96402834

96402843

115

96402836

96402844

230

2" non ANSI 4 bolt w/ (4) 0.56" dia. holes

Flange type
GF 50

Electrical data
Max amps
[A]

Speed

P Max
[Watts]

Start amps
[A]

115V

230V

115V

230V

3

5.85

2.95

630

14.60

7.30

2

5.80

2.90

610

14.48

7.18

1

5.70

2.85

600

14.23

7.05

45

UPS 50-80/2

Curve charts and technical data

UP, UPS Series 200

9

UPS 50-80/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

10
8
6
4
2
0

3
2
1

0
P1 [hp] P1 [W]
800
1.0
600
400
0.5
200
0.0
0
0

20

40

5

10

20

40

60

80 100 120 140 160 Q [US GPM]

15

20

25

30

35

Q [m³/h]

80 Eta [%]
3 60
40
2
1
Eta
20
0
80 100 120 140 160 Q [US GPM]

60

Flow range:

20 - 150 gpm

Head range:

1 - 30 ft

Motor:

2-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

49.5 lbs (20.8 kg)

Gross wt.:

53.4 lbs (24.2 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

52.2 lbs (23.7 kg)

Gross wt. bronze:

59.7 lbs (27.1 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9503 0307

H [ft]
35
30
25
20
15
10
5
0
0

H [m]

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

L3

TM02 0730 5100

L1

D6
D7

D1

D5

M
NPT 1/4

B4

D2

B5

Dimensions
Model
UPS 50-80/2

L1

L3

B1

B2

B4

B5

B7

H1

[in]

11.5

7.00

5.31

5.56

3.75

3.00

4.75

3.00

[mm]

292

178

135

141

95

76

121

76

Product numbers

H3

D1

9.88 12.86 2.13
251

327

54

D2

D3

D4

D5

D6

D7

3.44

4.06

5.25

0.55

2.50

3.06

87

103

133

14

64

78

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402838

96402845

208-230

96402840

96402846

460

96402842

96402847

575 ★

Model type

UPS 50-80/2
(3 ph)

H2

Flange size
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes

Flange type
GF 50

Electrical data
Max amps
[A]

Speed

46

208-230V

460V

575V ★

3

1.92

0.96

0.77

2

1.20

0.60

0.48

1

1.08

▲

▲

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]
208-230V

460V

575V ★

610

9.30

4.70

3.76

440

5.81

2.94

2.40

400

5.23

▲

▲

UP, UPS Series 200

9

UPS 50-160/2
1 ph, 230 V, 60 Hz

H [ft]
50

H [m]
14
12
10
8
6
4
2
0

3
2
1

40

Flow range:

20 - 170 gpm

Head range:

1 - 46 ft

Motor:

2-pole 1.50 Hp

Max. liquid temp (Open):

+140 °F

30

Max. liquid temp.:

+248 °F

20

Min. liquid temp.:

+32 °F

10
0
0

20 40 60 80 100 120 140 160 180 Q [US GPM]

0
P1 [hp] P1 [W]
2.0 1500
1.5 1000
1.0
500
0.5
0.0
0
0

5

10

15

20

25

30

35

40

Q [m³/h]
60 Eta [%]

3

145 psi

Net wt:

53.6 lbs (24.3 kg)

Gross wt.:

65.9 lbs (29.9 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

68.3 lbs (31.0 kg)

Gross wt. bronze:

80.7 lbs (36.6 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

40
20

Eta

0
20 40 60 80 100 120 140 160 180 Q [US GPM]

TM00 9413 0307

2

1

Max. system pressure:

Curve charts and technical data

UPS 50-160/2, 1 ph, 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

D5

M

TM02 0730 5100

L3

L1

D6
D7

D1

NPT 1/4

B4

D2

B5

Dimensions
Model
UPS 50-160/2

L1

L3

14.00 7.00

[in]
[mm]

356

178

B1

B2

B4

B5

B7

5.75

6.68

3.94

3.94

4.75

146

170

100

100

121

Product numbers

H2

H3

D1

3.00 10.81 13.78 2.13
76

275

350

54

D2

D3

D4

D5

D6

D7

3.44

4.05

5.25

0.55

2.50

3.06

87

103

133

14

64

78

M

M12

Connections
Product number

Model type
UPS 50-160/2
(1 ph)

H1

Cast Iron

Bronze

96411613

96411614

Voltage
[V]

Flange size
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes

Flange type
GF 50

230

Electrical data
Speed

Max amps
[A]

P Max
[Watts]

230V
3

5.80

2
1

Start amps
[A]
230V

1250

26.50

5.20

1100

23.76

4.85

1050

22.16

47

UPS 50-160/2

Curve charts and technical data

UP, UPS Series 200

9

UPS 50-160/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575, 60 Hz

H [m]
14
12
10
8
6
4
2
0

H [ft]
50
40

3
2
1

Flow range:

20 - 170 gpm

Head range:

1 - 46ft

Motor:

2-pole 1.50 Hp

Max. liquid temp (Open):

+140 °F

30

Max. liquid temp.:

+248 °F

20

Min. liquid temp.:

+32 °F

10
0

0
P1 [hp] P1 [W]
2.0 1500
1.5 1000
1.0
500
0.5
0.0
0
0

20 40 60 80 100 120 140 160 180 Q [US GPM]
5

10

15

20

25

30

35

40

Q [m³/h]
60 Eta [%]

3

40

2
1
Eta

20

0
20 40 60 80 100 120 140 160 180 Q [US GPM]

145 psi

Net wt:

53.6 lbs (24.3 kg)

Gross wt.:

65.9 lbs (29.9 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

68.3 lbs (31 kg)

Gross wt. bronze:

80.7 lbs (36.6 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9504 0307

0

Max. system pressure:

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

D5

M

TM02 0730 5100

L3

L1

D6
D7

D1

NPT 1/4

B4

D2

B5

Dimensions
Model

L1
[in]

UPS 50-160/2

[mm]

L3

14.00 7.00
356

178

B1

B2

B4

B5

B7

5.75

6.68

3.94

3.94

4.75

146

170

100

100

121

H1

76

Product numbers

H3

D1

275

350

54

D2

D3

D4

D5

D6

D7

3.44

4.05

5.25

0.55

2.50

3.06

87

103

133

14

64

78

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402860

96402866

208-230

96402861

96402868

460

96402862

96402870

575 ★

Model type

UPS 50-160/2
(3 ph)

H2

3.00 10.81 13.78 2.13

Flange size
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes

Flange type
GF 50

Electrical data
Max amps
[A]

Speed

48

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

3

4.00

2.00

1.60

1300

22.80

11.40

575V ★
9.12

2

3.00

1.50

1.20

1000

17.10

8.55

6.84

1

2.75

▲

▲

950

15.68

▲

▲

UP, UPS Series 200

9

UPS 50-240/2

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [ft]
70
3
60
2
50 1
40
30
20
10
0
0 20 40 60 80 100 120 140 160 180 Q [US GPM]

20
15
10
5
0

0
P1 [hp] P1 [W]
2000
2 1500
1000
1
500
0
0
0

5

10

15

20

25

30

35

40

Q [m³/h]

80 Eta [%]
60
3
2
40
1
Eta
20
0
20 40 60 80 100 120 140 160 180 Q [US GPM]

Flow range:

20 - 180 gpm

Head range:

1 - 62 ft

Motor:

2-pole 2.00 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

60.6 lbs (27.5 kg)

Gross wt.:

73.0 lbs (33.1 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

67.2 lbs (30.5 kg)

Gross wt. bronze:

79.6 lbs (36.1 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9505 0307

H [m]

Curve charts and technical data

UPS 50-240/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

L3

TM02 0730 5100

L1

D6
D7

D1

D5

M
NPT 1/4

B4

B5

H2

H3

D2

Dimensions
Model

L1

UPS 50-240/2

[in]
[mm]

L3

14.00 7.00
356

178

B1

B2

B4

B5

B7

H1

5.75

6.68

3.75

2.94

4.75

2.94

146

170

95

75

121

75

Product numbers

D3

D4

D5

D6

D7

4.19

5.00

6.00

0.55

3.50

4.00

251

106

127

152

14

89

102

350

D1

52

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402882

96402885

208-230

96402883

96402886

460

96402884

96402887

575 ★

Model type

UPS 50-240/2
(3 ph)

D2

9.88 13.78 2.06

Flange size
2" non ANSI 4 bolt w/ (4) 0.56" dia. holes

Flange type
GF 50

Electrical data
Max amps
[A]

Speed

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

575V ★

3

5.80

2.65

2.12

1700

26.50

15.40

12.32

2

3.95

1.98

1.68

1300

23.10

11.51

9.21

1

3.50

▲

▲

1150

20.47

▲

▲

49

UPS 53-55/57

Curve charts and technical data

UP, UPS Series 200

9

UPS 53-55/57, 1 ph, 115 V, 230 V, 60 Hz

1 ph, 115 V, 230 V, 60 Hz

10
8
6
4
2
0

H [ft]
35
30
25
20
15
10
5
0
0

3
2
1

20

0
P1 [hp] P1 [W]
800
1.0
600
400
0.5
200
0.0
0
0

5

20

40

60

10

40

80 100 120 140 160 Q [US GPM]

15

20

25

30

35

Q [m³/h]

80 Eta [%]
60
3
2
40
1
20
Eta
0
80 100 120 140 160 Q [US GPM]

60

Flow range:

20 - 150 gpm

Head range:

1 - 30 ft

Motor:

4-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

46.7 lbs (21.2 kg)

Gross wt.:

54.2 lbs (24.6 kg)

Shipping volume:

2.10 ft3 (0.06 m3)

Net wt. bronze:

52.2 lbs (23.7 kg)

Gross wt. bronze:

59.7 lbs (27.1 kg)

Shipping volume bronze:

2.10 ft3 (0.06 m3)

TM00 9520 0307

H [m]

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

TM02 0730 5100

L3

L1

D6
D7

D1

D5

M
NPT 1/4

B4

D2

B5

Dimensions
Model
UPS 53-55/57

[in]
[mm]

L1

L3

B1

B2

B4

B5

B7

H1

11.88

5.94

5.31

5.56

3.75

2.94

4.75

2.94

302

151

135

141

95

75

121

75

Product numbers
Product number

D2

D3

D4

D5

D6

D7

9.88 12.86 2.06

4.19

5.00

6.00

0.63

3.50

4.00

251

106

127

152

16

89

102

50

327

D1

52

Flange size

Voltage
[V]

Cast Iron

Bronze

M

M12

96654373

96654392

115

96654374

96654393

230

Max amps
[A]

P Max
[Watts]

Flange type

2.0",2.5",3.0" non ANSI 4 bolt w/ (4) 0.63" dia. holes GF 53

Electrical data
Speed

H3

Connections

Model type
UPS 53-55/57
(1 ph)

H2

Start amps
[A]

115V

230V

115V

230V

3

5.85

2.95

630

14.60

7.30

2

5.80

2.85

613

14.48

7.18

1

5.70

2.80

600

14.23

7.05

UP, UPS Series 200

9

UPS 53-55/57

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

10
8
6
4
2
0

3
2
1

0
P1 [hp] P1 [W]
800
1.0
600
400
0.5
200
0.0
0
0

20

40

5

10

20

40

60

80 100 120 140 160 Q [US GPM]

15

20

25

30

35

Q [m³/h]

80 Eta [%]
3 60
40
2
1
Eta
20
0
80 100 120 140 160 Q [US GPM]

60

Flow range:

20 - 150 gpm

Head range:

1 - 30 ft

Motor:

2-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

46.7 lbs (21.2 kg)

Gross wt.:

54.2 lbs (24.6 kg)

Shipping volume:

2.10 ft3 (0.06 m3)

Net wt. bronze:

52.2 lbs (23.7 kg)

Gross wt. bronze:

59.7 lbs (27.1 kg)

Shipping volume bronze:

2.10 ft3 (0.06 m3)

TM00 9503 0307

H [ft]
35
30
25
20
15
10
5
0
0

H [m]

Curve charts and technical data

UPS 53-55/57, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

L3

TM02 0730 5100

L1

D6
D7

D1

D5

M
NPT 1/4

B4

B5

H2

H3

D2

Dimensions
Model
[in]

UPS 53-55/57

[mm]

L1

L3

B1

B2

B4

B5

B7

H1

11.88

5.94

5.31

5.56

3.75

2.94

4.75

2.94

302

151

135

141

95

75

121

75

Product numbers

D3

D4

D5

D6

D7

4.19

5.00

6.00

0.63

3.50

4.00

251

106

127

152

16

89

102

327

D1

52

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96654375

96654394

208-230

96654376

96654395

460

96654377

96654396

575 ★

Model type

UPS 53-55/57
(3 ph)

D2

9.88 12.86 2.06

Flange size
2.0",2.5",3.0" non ANSI 4 bolt w/ (4) 0.63" dia. holes

Flange type
GF 53

Electrical data
Max amps
[A]

Speed

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

575V ★

3

1.92

0.96

0.77

610

9.30

4.70

3.76

2

1.20

0.60

0.48

440

5.81

2.94

2.40

1

1.08

▲

▲

400

5.23

▲

▲

51

UPS 75-69/2

Curve charts and technical data

UP, UPS Series 200

9

UPS 75-69/2, 1 ph, 230 V, 60 Hz

1 ph, 230 V, 60 Hz

H [ft]
50

H [m]
14
12
10
8
6
4
2
0

3
2
1

40

Flow range:

20 - 170 gpm

Head range:

1 - 46 ft

Motor:

2-pole 1.25 Hp

Max. liquid temp (Open):

+140 °F

30

Max. liquid temp.:

+248 °F

20

Min. liquid temp.:

+32 °F

10
0
0

20 40 60 80 100 120 140 160 180 Q [US GPM]

0
P1 [hp] P1 [W]
2.0 1500
1.5 1000
1.0
500
0.5
0.0
0
0

5

10

15

20

25

30

35

40

Q [m³/h]
60 Eta [%]

145 psi

Net wt:

53.6 lbs (24.3 kg)

Gross wt.:

65.7 lbs (29.8 kg)

Shipping volume:

3.50 ft3 (0.098 m3)

Net wt. bronze:

68.3 lbs (31.0 kg)

Gross wt. bronze:

80.5 lbs (36.5 kg)

Shipping volume bronze:

3.50 ft3 (0.098 m3)

40
20

Eta

0
20 40 60 80 100 120 140 160 180 Q [US GPM]

TM00 9413 0307

3

2

1

Max. system pressure:

Note: ETA is calculated as wire-to-water efficiency.

B1

D4

H3
H2

D3

B7

B

2

H1

L3

TM02 0730 5100

L1

D6
D7

D1

D5

M
NPT 1/4

B4

B5

H2

H3

D2

Dimensions
Model
UPS 75-69/2

[in]

L1

L3

B1

B2

B4

B5

B7

H1

14.25

7.13

5.69

6.68

3.94

3.94

4.50

2.94

362

181

145

170

100

100

114

75

[mm]

Product numbers
Product number
Cast Iron

Bronze

96654378

96654397

Voltage
[V]
230

Electrical data
Speed

Max amps
[A]

P Max
[Watts]

230V

52

3

5.80

2
1

275

350

D1

D2

D3

D4

D5

D6

D7

2.94

4.31

6.00

7.50

0.75

6.50

4.00

75

109

152

191

19

165

102

M

M12

Connections

Model type
UPS 75-69/2
(1 ph)

10.81 13.78

Start amps
[A]
230V

1250

26.50

5.20

1100

23.76

4.85

1050

22.16

Flange size
3" ANSI 125# R.F.

Flange type
GF80

UP, UPS Series 200

9

UPS 75-69/2

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [ft]
50

H [m]
14
12
10
8
6
4
2
0

40

3
2
1

Flow range:

20 - 170 gpm

Head range:

1 - 46 ft

Motor:

2-pole 1.25 Hp

Max. liquid temp (Open):

+140 °F

30

Max. liquid temp.:

+248 °F

20

Min. liquid temp.:

+32 °F

10

Max. system pressure:

145 psi

Net wt:

53.6 lbs (24.3 kg)

0
0

20 40 60 80 100 120 140 160 180 Q [US GPM]

0
P1 [hp] P1 [W]
2.0 1500
1.5 1000
1.0
500
0.5
0.0
0
0

5

10

15

20

25

30

35

40

Q [m³/h]
60 Eta [%]

3

Eta

20

0
20 40 60 80 100 120 140 160 180 Q [US GPM]

65.7 lbs (29.8 kg)

Shipping volume:

3.50 ft3 (0.098 m3)

Net wt. bronze:

68.3 lbs (31.0 kg)

Gross wt. bronze:

80.5 lbs (36.5 kg)

Shipping volume bronze:

3.50 ft3 (0.098 m3)

TM00 9504 0307

40

2
1

Gross wt.:

Curve charts and technical data

UPS 75-69/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

TM02 0730 5100

L3

L1

D6
D7

D1

D5

M
NPT 1/4

B4

D2

B5

Dimensions
Model
[in]

UPS 75-69/2

L1

L3

B1

B2

B4

B5

B7

H1

14.25

7.13

5.69

6.68

3.94

3.94

4.50

2.94

362

181

145

170

100

100

114

75

[mm]

Product numbers

H3

275

350

D1

D2

D3

D4

D5

D6

D7

2.94

4.31

6.00

7.50

0.75

6.50

4.00

75

109

152

191

19

165

102

M

M12

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96654379

96654398

208-230

96654390

96654399

460

96654391

96654400

575 ★

Model type

UPS 75-69/2
(3 ph)

H2

10.81 13.78

Flange size
3" ANSI 125# R.F.

Flange type
GF80

Electrical data
Max amps
[A]

Speed

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

3

4.00

2.00

1.60

1300

22.80

11.40

575V ★
9.12

2

3.00

1.50

1.20

1000

17.10

8.55

6.84

1

2.75

▲

▲

950

15.68

▲

▲

53

UPS 80-40/4

Curve charts and technical data

UP, UPS Series 200

9

UPS 80-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

4
3
2
1
0

3
2
1

40

0
P1 [hp] P1 [W]
600
0.8
0.6
400
0.4
200
0.2
0.0
0
0

80

10

120

20

160

30

200 Q [US GPM]
Q [m³/h]

40

60 Eta [%]

1

40

80

120

2

3

40

Eta

20

0
200 Q [US GPM]

160

Flow range:

30 - 200 gpm

Head range:

1 - 13 ft

Motor:

4-pole 0.5 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

78.7 lbs (35.7 kg)

Gross wt.:

9.1 lbs (41.3 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

91.9 lbs (41.7 kg)

Gross wt. bronze:

104.3 lbs (47.3 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9506 0307

H [ft]
16
14
12
10
8
6
4
2
0
0

H [m]

Note: ETA is calculated as wire-to-water efficiency.

H1

D3

B7

B

2

D4

H3
H2

B1

L3

TM02 0730 5100

L1

D6
D7

D1

D5

M
NPT 1/4

B4

B5

H2

H3

D2

Dimensions
L1

Model
[in]

UPS 80-80/4

[mm]

L3

19.00 9.50
483

241

B1

B2

B4

B5

B7

H1

5.75

6.68

4.94

3.94

6.31

3.81

146

170

125

100

160

97

Product numbers

11.25 15.15 3.19
286

385

81

D2

D3

D4

D5

D6

D7

5.00

6.00

7.56

0.75

—

—

127

152

192

19

—

—

M

M16

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402894

96402899

208-230

96402895

96402900

460

96402896

96402901

575 ★

Model type

UPS 80-40/4
(3 ph)

D1

Flange size
3" ANSI 125# R.F.

Flange type
GF80

Electrical data
Max amps
[A]

Speed

54

208-230V

460V

575V ★

3

1.62

0.81

0.65

2

0.87

0.44

0.35

1

0.77

▲

▲

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]
208-230V

460V

575V ★

380

7.10

3.50

2.80

260

3.81

1.90

1.52

230

3.37

▲

▲

UP, UPS Series 200

9

UPS 80-80/4
3 ph, 208-230 V, 60 Hz

H [ft]
30
25

3

20

2
1

15
10
5
0
0

50

0
P1 [hp] P1 [W]
1.5 1200
800
1.0
400
0.5
0.0

10

100
20

150
30

200
40

250

50

300 Q [US GPM]
Q [m³/h]

60

60 Eta [%]

3
1

40

2
Eta

0
0

50

100

150

200

250

20

0
300 Q [US GPM]

Flow range:

30 - 260 gpm

Head range:

1 - 25 ft

Motor:

4-pole 1.50 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

89.7 lbs (40.7 kg)

Gross wt.:

102.1 lbs (46.3 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

102.3 lbs (46.4 kg)

Gross wt. bronze:

114.6 lbs (52.0 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9507 0307

H [m]
9
8
7
6
5
4
3
2
1
0

Curve charts and technical data

UPS 80-80/4, 3 ph, 208-230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H3
H2

B1

D4
D3
D2
D1

B7

NPT 1/4

B4

B5

H3

D1

TM02 0731 5100

M

D5

L3

L1

B

2

H1

Dimensions
Model
UPS 80-80/4

L1

L3

19.00 9.50

[in]
[mm]

483

241

B1

B2

B4

B5

B7

H1

5.75

6.68

4.94

3.94

6.31

3.81

146

170

125

100

160

97

Product numbers

286

385

81

D2

D3

D4

D5

D6

D7

5.00

6.00

7.56

0.75

—

—

127

152

192

19

—

—

M

M16

Connections
Product number

Model type
UPS 80-80/4
(3 ph)

H2

11.25 15.15 3.19

Cast Iron

Bronze

96402908

96402913

Voltage
[V]

Flange size
3" ANSI 125# R.F.

Flange type
GF80

208-230

Electrical data
Speed

Max amps
[A]

P Max
[Watts]

230V

Start amps
[A]
230V

3

3.60

1050

11.80

2

2.08

660

6.82

1

1.72

550

5.64

55

UP 80-160/2

Curve charts and technical data

UP, UPS Series 200

9

UPS 80-160/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

H [ft]
50

H [m]
14
12
10
8
6
4
2
0

3

40

1

2

30 - 275 gpm

Head range:

1 - 49 ft

Motor:

2-pole 3.00 Hp

Max. liquid temp (Open):

+140 °F

30

Max. liquid temp.:

+248 °F

20

Min. liquid temp.:

+32 °F

10

Max. system pressure:

145 psi

Net wt:

85.1 lbs (38.6 kg)

0
50

0
P1 [W]
3000

10

100
20

150
30

200
40

250

50

300 Q [US GPM]
Q [m³/h]

60

60 Eta [%]

2000
2

1

1000

40

3

20
Eta

0
0

50

100

150

200

0
300 Q [US GPM]

250

Gross wt.:

97.4 lbs (44.2 kg)

Shipping volume:

2.90 ft3 (0.082 m3)

Net wt. bronze:

97.2 lbs (44.1 kg)

Gross wt. bronze:

109.6 lbs (49.7 kg)

Shipping volume bronze:

2.90 ft3 (0.082 m3)

TM00 9508 00307

0
P1 [hp]
4
3
2
1
0

Flow range:

Note: ETA is calculated as wire-to-water efficiency.

H3
H2

B1

D4
D3
D2
D1

B7

NPT 1/4

B4

TM02 0731 5100

M

D5

L3

L1

B

2

H1

B5

Dimensions
Model

L1
[in]

UPS 80-160/2

[mm]

L3

19.00 9.50
483

241

B1

B2

B4

B5

B7

H1

5.75

6.68

3.94

3.94

6.31

146

170

100

100

160

H3

D1

3.81 11.31 15.20 3.19
97

Product numbers

287

386

81

D2

D3

D4

D5

D6

D7

5.00

6.00

7.56

0.75

—

—

127

152

192

19

—

—

M

M16

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402920

96402923

208-230

96402921

96402924

460

96402922

96402925

575 ★

Model type

UPS 80-160/2
(3 ph)

H2

Flange size
3" ANSI 125# R.F.

Flange type
GF80

Electrical data
Max amps
[A]

Speed

56

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]

208-230V

460V

575V ★

208-230V

460V

575V ★

3

6.35

3.13

2.54

2050

31.00

15.40

12.32

2

4.20

2.10

1.68

1550

20.50

10.17

8.14

1

4.05

▲

▲

1500

19.77

▲

▲

UP, UPS Series 200

9

UP 100-40/4

3 ph, 208-230 V, 460 V, 575 V, 60 Hz

4
3
2
1
0

3
2
1

50

0
P1 [hp] P1 [W]
600
0.8
0.6
400
0.4
200
0.2
0.0
0
0

100

10

20

150
30

200
40

250

50

300 Q [US GPM]
Q [m³/h]

60

60 Eta [%]
3

2

1

40
Eta

50

100

150

200

20

0
300 Q [US GPM]

250

Flow range:

30 - 270 gpm

Head range:

1 - 12 ft

Motor:

4-pole, 1.00 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+248 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

126.8 lbs (57.5 kg)

Gross wt.:

138.9 lbs (63.0 kg)

Shipping volume:

3.53 ft3 (0.1 m3)

Net wt. bronze:

153.2 lbs (69.5 kg)

Gross wt. bronze:

165.3 lbs (75.0 kg)

Shipping volume bronze:

3.53 ft3 (0.1 m3)

TM00 9509 0307

H [ft]
14
12
10
8
6
4
2
0
0

H [m]

Curve charts and technical data

UPS 100-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

D4
D3
D1

B7

M
NPT 1/4

B4

D5

L3

D2

L1

B

2

H1

TM02 0732 5100

H3
H2

B1

B5

Dimensions
Model

L1
[in]

UPS 100-40/4

[mm]

L3

B1

21.00 10.50 5.75
533

267

146

B2

B4

B5

B7

6.68

5.13

3.94

6.31

170

130

100

160

H1

D2

D3

D4

D5

D6

D7

4.81 12.31 16.61 4.19

6.19

7.50

9.06

0.75

—

—

122

157

191

230

19

—

—

roduct numbers

313

H3

422

D1

106

M

M16

Connections
Product number
Cast Iron

Bronze

Voltage
[V]

96402934

96402937

208-230

96402935

96402938

460

96402936

96401961

575 ★

Model type

UPS 100-40/4
(3 ph)

H2

Flange size
4" ANSI 125# R.F.

Flange type
GF100

Electrical data
Max amps
[A]

Speed
208-230V

460V

575V ★

3

2.50

1.24

1.00

2

1.38

0.70

0.55

1

1.24

▲

▲

▲ All 3-phase, 460V and 575V pumps are 2-speed only.
★ Canada only.

Start amps
[A]

P Max
[Watts]
208-230V

460V

575V ★

570

10.80

5.40

4.32

435

5.96

3.05

2.44

390

5.36

▲

▲

57

UP 43-70

Curve charts and technical data

UP, UPS Series 200

9

UP 43-70, 1 ph, 115 V / 230 V, 60 Hz

1 ph, 115 V / 230 V, 60 Hz

8
6
4
2
0

P1 [hp]
0.6
0.4
0.2
0.0

H [ft]
28
24
20
16
12
8
4
0
0

10 20 30 40 50 60 70 80 90 100 Q [US GPM]

0
P1 [W]
500
400
300
200
100
0
0

5

10

15

20

Flow range:

15 - 100 gpm

Head range:

1 - 23 ft

Motor:

2-pole 0.50 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+230 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

33.1 lbs (15.0 kg)

Gross wt.:

41.2 lbs (18.7 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

Q [m³/h]

50 Eta [%]
40
30
20
Eta
10
0
10 20 30 40 50 60 70 80 90 100 Q [US GPM]
P1

TM02 0079 0307

H [m]

Note: ETA is calculated as wire-to-water efficiency.

H3

B1

B

2

H1

H2

B7

B4

D1
D2
D3

TM02 0120 4301

M
NPT 1/4

D7
D6

L3

L1

D4

D5

B5

Dimensions
Model
UP 43-70

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

[in]

8.50

4.25

5.25

5.56

2.94

2.94

3.13

2.63

9.63

12.23

1.63

2.31

[mm]

216

108

133

141

75

75

79

67

244

311

41

59

Product numbers

D4

D5

87

121

13

D6

D7

2.06

2.50

52

64

M

M12

Connections
Product number

Model type
Cast Iron
UP 43-70
(1 ph)

96439644

Max amps
[A]

P Max
[Watts]

115V

230V

3.4

1.8

Voltage
[V]
115/230

Electrical data

58

D3

3.42 4.75 0.50

400

Flange size
1.50" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

UP, UPS Series 200

9

UP 43-110
1 ph, 115 V / 230 V, 60 Hz

10
8
6
4
2
0

P1 [hp]
1.2
0.8
0.4
0.0

H [ft]
40
35
30
25
20
15
10
5
0
0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM]
0
5
10
15
20
Q [m³/h]
P1 [W]
1000
50 Eta [%]
800
40
600
30
P1
400
20
Eta
200
10
0
0
0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM]

Flow range:

15 - 105 gpm

Head range:

1 - 37 ft

Motor:

2-pole 0.75 Hp

Max. liquid temp (Open):

+140 °F

Max. liquid temp.:

+230 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

33.1 lbs (15.0 kg)

Gross wt.:

41.2 lbs (18.7 kg)

Shipping volume:

1.70 ft3 (0.048 m3)

TM02 0076 0307

H [m]
12

Curve charts and technical data

UP 43/110, 1 ph, 115 V / 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H3

B1

B

2

H1

H2

B7

B4

D1
D2
D3

TM02 0120 3902

M
NPT 1/4

D7
D6

L3

L1

D4

D5

B5

Dimensions
Model
UP 43-110

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

[in]

8.50

4.25

5.25

5.56

2.94

2.94

3.13

2.63

9.63

12.23

1.63

2.94

[mm]

216

108

133

141

75

75

79

67

244

311

41

75

Product numbers

D3

D4

D5

3.42 4.75 0.50
87

121

13

D6

D7

2.06

2.50

52

64

M

M12

Connections
Product number

Model type
Cast Iron
UP 43-100 (1 ph)

96436943

Voltage
[V]

Flange size
1.50" non ANSI 2 bolt w/ (2) 0.5" dia. holes

Flange type
GF 40/43

115/230

Electrical data
Max amps
[A]

P Max
[Watts]

115V

230V

4.9

2.5

570

59

UP 53-45

Curve charts and technical data

UP, UPS Series 200

9

UP 53-45, 1 ph, 115 V / 230 V, 60 Hz

1 ph, 115 V / 230 V, 60 Hz

H [m]

Flow range:

15 - 100 gpm

Head range:

1 - 23 ft

20

Motor:

2-pole 0.50 Hp

16

Max. liquid temp (Open):

+140 °F

12

Max. liquid temp.:

+230 °F

Min. liquid temp.:

+32 °F

H [ft]
24

6
4

8

2

4
0

0
0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM]

0.6
0.4
0.2
0.0

145 psi

Net wt:

44.4 lbs (20.2 kg)

Gross wt.:

63.5 lbs (23.8 kg)

Shipping volume:

2.10 ft3 (0.06 m3)

Net wt. bronze:

49.2 lbs (22.3 kg)

Gross wt. bronze:

57.1 lbs (25.9 kg)

Shipping volume bronze:

2.10 ft3 (0.06 m3)

TM03 5370 0307

0
5
10
15
20
Q [m³/h]
P1 [W]
500
50 Eta [%]
P1
400
40
300
30
200
20
Eta
100
10
0
0
0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM]

P1 [hp]

Max. system pressure:

Note: ETA is calculated as wire-to-water efficiency.

H3

B1
B

2

H1

D4
H2

D3

B7

D5

L3

M

TM03 7230 1608

L1

D6
D7

D1

B4

NPT 1/4

D2

B5

Dimensions
Model
UP 53-45

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

[in]

9.88

5.00

5.25

5.56

3.56

2.94

4.75

2.94

9.88

12.86

2.06

4.19

5.00 6.00 0.63

[mm]

251

127

133

141

90

75

121

75

251

327

52

106

127

Product numbers
Product number
Cast Iron

Bronze

96633576

96633578

Electrical data
Max amps
[A]

60

D4

152

D5

16

D6

D7

3.50

4.00

89

102

M

M12

Connections

Model type
UP 53-45 (1 ph)

D3

P Max
[Watts]

115V

230V

3.5

1.9

360

Voltage
[V]
115/230

Flange size

Flange type

2.0",2.5",3.0" non ANSI 4 bolt w/ (4) 0.63" dia. holes GF 53

UP, UPS Series 200

9

UP 53-46
1 ph, 115 V / 230 V, 60 Hz

H [m]

Flow range:

15 - 105 gpm

Head range:

1 - 37 ft

20

Motor:

2-pole 0.75 Hp

16

Max. liquid temp (Open):

+140 °F

H [ft]
24

6
4

12
8

2

4
0

0
0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM]

0.6
0.4
0.2
0.0

+230 °F

Min. liquid temp.:

+32 °F

Max. system pressure:

145 psi

Net wt:

44.5 lbs (20.2 kg)

Gross wt.:

63.5 lbs (23.8 kg)

Shipping volume:

2.10 ft3 (0.06 m3)

Net wt. bronze:

49.2 lbs (22.3 kg)

Gross wt. bronze:

57.1 lbs (25.9 kg)

Shipping volume bronze:

2.10 ft3 (0.06 m3)

TM03 5371 0307

0
5
10
15
20
Q [m³/h]
P1 [W]
500
50 Eta [%]
P1
400
40
300
30
200
20
Eta
100
10
0
0
0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM]

P1 [hp]

Max. liquid temp.:

Curve charts and technical data

UP 53-46, 1 ph, 115 V / 230 V, 60 Hz

Note: ETA is calculated as wire-to-water efficiency.

H3

B1
B

2

H1

D4
H2

D3

B7

D5

L3

M

TM03 7230 1608

L1

D6
D7

D1

B4

NPT 1/4

D2

B5

Dimensions
Model
UP 53-46

L1

L3

B1

B2

B4

B5

B7

H1

H2

H3

D1

D2

D3

D4

D5

D6

D7

[in]

9.88

5.00

5.25

5.56

3.56

2.94

4.75

2.94

9.88

12.86

2.06

4.19

5.00

6.00

0.63

3.50

4.00

[mm]

251

127

133

141

90

75

121

75

251

327

52

106

127

152

16

89

102

Product numbers

M12

Connections
Product number

Model type
UP 53-46
(1 ph)

M

Cast Iron

Bronze

96633591

96633592

Voltage
[V]

Flange size

Flange type

2.0",2.5",3.0" non ANSI 4 bolt w/ (4) 0.63" dia. holes GF 53

115/230

Electrical data
Max amps
[A]

P Max
[Watts]

115V

230V

3.9

2.1

420

61

UP, UPS Series 200

10
Accessories and spare parts

10. Accessories and spare parts
Packaged fitting sets
Pump connection

Pipe connection
type & size

Product number

Approx. ship. wt.
(lb/oz.)

3/4

519601

2 lb 4 oz.

1

519602

2 lb 4 oz.

1-1/4

519603

2 lb 2 oz.

NPT

Flange sets

Cast iron

GF 15/26 flange

1-1/2

519604

2 lb 2 oz.

1-1/2

539605

2 lb 7 oz.

2

96409354

6.5 lb

2

91584910

12 lb

GF 53 flange

2-1/2

91584911

12 lb

3

91584912

12 lb

GF 65 flange

2-1/2

559601

16 lb

GF 80 flange

3

569601

19 lb

GF 100 flange

4

579801

33 lb

3/4

519651

2 lb 2 oz.

1

519652

2 lb 3 oz.

1-1/4

96409356

2 lb 1 oz.

GF 40/43 flange
GF 50 flange

GF 15/26 flange

Bronze

GF 40/43 flange

1-1/2

539615

3 lb

GF 50 flange

2

96409355

6.3 lb

2

91584913

12 lb

GF 53 flange

2-1/2

91584914

12 lb

3

91584915

12 lb

GF 80 flange

3

569611

20 lb

GF 100 flange

4

96409357

30 lb

 Flange sets include: 2 each - flanges, gaskets, bolts with nuts.

Flange adapter

Terminal box electrical components

62

For use with these pumps

Description

1-phase x 115/230 V UPS
3-phase x 208-230 V UPS

Product number

Speed plug for 3-speed

96401124
96401001

1-phase x 115 V UPS
1-phase x 230 V UPS
3-phase x 208-230 V UPS

Power head relay module

96409246
96409247
96409250

1-phase x 115 V
1-phase x 230 V
3-phase x 208-230 V

Protection module service

96427457
96427458
96427459

UP, UPS Series 200

11
Further documentation

11. Further documentation
WebCAPS
WebCAPS is a Web-based Computer Aided Product
Selection program available on www.grundfos.com.
WebCAPS contains detailed information on more than
185,000 Grundfos products in more than 20
languages.
In WebCAPS, all information is divided into 6 sections:
• Catalog
• Literature
• Service
• Sizing
• Replacement
• CAD drawings.
Catalog
This section is based on fields of application and pump types,
and contains
• technical data
• curves (QH, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of
pumps in operation
• product photos
• dimensional drawings
• wiring diagrams
• quotation texts, etc.

Literature
In this section you can access all the latest documents of a given
pump, such as
• product guides
• installation and operating instructions
• service documentation, such as Service kit catalog
and Service kit instructions
• quick guides
• product brochures, etc.

Service
This section contains an easy-to-use interactive service catalog.
Here you can find and identify service parts of both existing and
discontinued Grundfos pumps.
Furthermore, this section contains service videos showing you
how to replace service parts.

63

UP, UPS Series 200

11
Further documentation

Sizing

0

1

This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how
to
• select the most suitable and efficient pump for your installation
• carry out advanced calculations based on energy consumption,
payback periods, load profiles, life cycle costs, etc.
• analyse your selected pump via the built-in life cycle cost tool
• determine the flow velocity in wastewater applications, etc.

Replacement
In this section you find a guide to selecting and comparing
replacement data of an installed pump in order to replace the
pump with a more efficient Grundfos pump.
The section contains replacement data of a wide range of pumps
produced by other manufacturers than Grundfos.
Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When
you have specified the installed pump, the guide will suggest a
number of Grundfos pumps which can improve both comfort and
efficiency.

CAD drawings
In this section it is possible to download 2-dimensional (2D) and
3-dimensional (3D) CAD drawings of most Grundfos pumps.
These formats are available in WebCAPS:
2-dimensional drawings:
• .dxf, wireframe drawings
• .dwg, wireframe drawings.
3-dimensional drawings:
• .dwg, wireframe drawings (without surfaces)
• .stp, solid drawings (with surfaces)
• .eprt, E-drawings.

WinCAPS
WinCAPS is a Windows-based Computer Aided
Product Selection program containing detailed information on more than 185,000 Grundfos products in
more than 20 languages.
The program contains the same features and functions
as WebCAPS, but is an ideal solution if no Internet
connection is available.
WinCAPS is available on CD-ROM and updated once
a year.
Fig. 14 WinCAPS CD-ROM

64

65

66

67

Being responsible is our foundation
Thinking ahead makes it possible
Innovation is the essence

Subject to alterations.
L-UPS-PG-01 0612
The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks
owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide.

ECM: -

GRUNDFOS Pumps Corporation
17100 West 118th Terrace
Olathe, Kansas 66061
Phone: +1-913-227-3400
Telefax: +1-913-227-3500

GRUNDFOS Canada Inc.
2941 Brighton Road
Oakville, Ontario L6H 6C9
Canada
Phone: +1-905 829 9533
Telefax: +1-905 829 9512

Bombas GRUNDFOS de Mexico S.A. de C.V.
Boulevard TLC No. 15
Parque Industrial Stiva Aeropuerto
Apodaca, N.L. Mexico 66600
Phone: +52-81-8144 4000
Telefax: +52-81-8144 4010



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Create Date                     : 2012:06:19 19:12:22Z
Creator                         : FrameMaker 10.0
Modify Date                     : 2014:09:15 08:44:18-04:00
Language                        : en
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Creator Tool                    : FrameMaker 10.0
Metadata Date                   : 2014:09:15 08:44:18-04:00
Producer                        : Acrobat Distiller 10.0.0 (Windows)
Format                          : application/pdf
Title                           : untitled
Document ID                     : uuid:8de25195-cd5b-4ac8-9bee-fcb8e7bdce81
Instance ID                     : uuid:fb3408fe-8eb5-4830-b800-cd04fa66c48d
Page Mode                       : UseOutlines
Page Count                      : 68
EXIF Metadata provided by EXIF.tools

Navigation menu