17550 1 Grundfos 96402708 Product Guide User Manual
537315 1 Grundfos Large Up-Ups Series 200 Product Guide 537315_1_Grundfos Large UP-UPS Series 200 Product Guide
537315 1 Grundfos Large Up-Ups Series 200 Pump Brochure 537315_1_Grundfos Large UP-UPS Series 200 Pump Brochure
User Manual: Pump 17550 1 Grundfos 96402708 Product Guide
Open the PDF directly: View PDF
.
Page Count: 68
| Download | |
| Open PDF In Browser | View PDF |
GRUNDFOS PRODUCT GUIDE Large UP, UPS Series 200 circulator pumps 60 Hz Large UP, UPS Table of contents 1. 2. 3. 4. 5. 6. 7. 8. 9. Product introduction 3 Introduction Terminal box modules Applications Features and benefits Identification 3 3 3 3 4 Product overview 5 Performance range, UPS pumps Performance range, UP pumps 5 6 Product range 7 Pump overview 7 Cross-reference guide 8 Armstrong, B&G and TACO to Grundfos 8 Construction 10 Construction Material specification Sectional drawing Motor Stator housing Rotor can Shaft with rotor Bearing plate Impeller Pump housing 10 11 11 12 12 12 12 12 12 12 Operating conditions 13 Pumped liquids Temperature limits Other technical data Electrical data Supply voltage tolerances Terminal box Insulation class 13 13 13 14 14 14 14 Functions 15 Functions Description of functions Standard module indicator lights Variable frequency drive operation Pumps with protection module Protection module indicator lights Pumps with relay module Relay module indicator lights Signal output of relay module Two pumps plumbed in parallel 15 16 17 17 17 18 18 18 18 18 Technical data 19 Technical data, UPS Curve conditions 19 24 Curve charts and technical data 25 10. Accessories and spare parts Packaged fitting sets Terminal box electrical components 2 62 62 62 11. Further documentation WebCAPS WinCAPS 63 63 64 UP, UPS Series 200 1 Introduction Applications The Grundfos UP(S) Series 200 line of wet rotor circulators is unique to commercial building services. Most competitor pumps are dry runners. UP(S) wet rotor circulators, on the other hand, are designed so that the water being pumped surrounds the rotor, cooling and lubricating the shaft and bearings. The pumps are designed for circulation of liquids in heating and air-conditioning systems. They can also be used in domestic hot-water systems. Applications for the UP(S) pumps include: • Heating systems for apartments, colleges, hospitals, institutions and schools • hot water recirculation for hotels, colleges institutions, hospitals, and apartments • large residential heating • snow melt. To ensure optimum operation, the dimensioning range of the system must fall within the performance range of the pump. See sections 6. Operating conditions on page 13 and 8. Technical data on page 19. Product introduction 1. Product introduction GrA3223, GrA3217 Pumped liquids Fig. 1 Grundfos UP, UPS Series 200 circulator pumps Wet rotor design eliminates the need for a fan to cool the motor. Fans are often a source of noise and vibrations that can resonate throughout a building via the pipework. Eliminating the fan results in very quiet operation. UP(S) Series 200 pumps are available in cast iron construction for closed (heating and air conditioning) and bronze construction for open (domestic hot water) systems. Both cast iron and bronze UP(S) Series 200 pumps utilize laser-welded stainless steel impellers to achieve high pump efficiency. The standard UP(S) motors are suitable for variable speed drive applications. Terminal box modules UPS pumps are equipped with a standard or protection module in the terminal box. Pumps with standard module must be connected to the power supply via an external contactor, whereas pumps with protection module can be connected directly to the power supply. For further information about the different modules, see pages 17 through 18. Grundfos UP, UPS Series 200 pumps are suitable for pumping thin, clean, non-aggressive and non-explosive liquids, not containing any solid particles, fibers or mineral oil. In domestic hot-water systems it is advisable to use bronze pumps only for water with a degree of hardness lower than approx. 14°dH. For water with a higher degree of hardness, a Grundfos TP dry-rotor pump is recommended. The pumps must not be used for the transfer of flammable liquids such as diesel oil and gasoline. For liquid temperature, see section 6. Operating conditions on page 13. Features and benefits The Grundfos range of UP(S) Series 200 circulator pumps offer many beneficial features: • Quiet • maintenance-free • UPS pumps have a 2 or 3 speed switch, which increases the comfort level for the application • small profile (one piece vs. three piece) • sealless, which eliminates worries about hot water leakage • pumped water lubricates the shaft and bearings so there is no oil to leak • no couplers to change. 3 UP, UPS Series 200 1 Product introduction Identification Type key Example UPS 50 -40 (/2) F (B) Type range - UP: Single-speed pump - UPS: Two- or three-speed pump Nominal flange diameter [mm] Max. head [dm]* Number of motor poles (stated if available both as 2- and 4-pole motor) Pump with flanges Pump with bronze housing *With the exception of the following pump types, where the number is to be considered as a reference number: UP 53-45, UP 53-46, UPS 53-55/57 and UPS 75-69 Nameplate 1 9 10 UPS 50-40 F 5 P/N:96402816 Model:C PC:0635 EMPLOYER UNIQUEMENT A L’INTERIERUR 8 4 Example of nameplate Description 1 Type code 2 Product number 3 Model designation 4 Production code (year + week) 5 Country of origin 6 Number of phases and rated voltage 7 Current at speeds 1, 2, 3 8 Power at speeds 1, 2, 3 9 Direction of rotation 10 Approvals 11 Temperature limits 12 Rated frequency 13 Capacitor size 14 Locked Rotor Amps 15 Insulation class US CSA ENCL. 2/BOITIER DE YPE 2 3 208-230V 60Hz P1 (W) I 1/1 (A) 1 0.54 1 150 170 2 0.66 2 270 3 1.40 3 F 4.0 (A) ClassF LRA 11 APPROVED FOR WATER: MAX T. 120°C/248F FOR INDOOR USE ONLY 7 Pos. C MADE IN GERMANY 6 Fig. 1 LISTED 1Z28 WATER-CIRCULATING PUMP MIN LIQUID T. -10°C/+14° F MAX LIQUID T. 120°C/+248° F 12 13 14 15 TM03 7712 4806 2 3 4 UP, UPS Series 200 2 Product overview 2. Product overview Performance range, UPS pumps The curves show maximum performance curves for the UPS range: • single-voltage pumps • two- and three-speed pumps. H [m] 20 H [ft] UPS 60 40-240 50 60 Hz 50240 40 32-160 10 9 30 8 40-80/2 53-5 5/57 7 6 50-160 75-69 40-160 20 32-80 5 5080 / 2 40-80/4 80-80 50 15 -8 0/4 4 3 80-160 10 8 2 6 32-40 40-40 50-40 80-40 100-40 4 1 3 2 15 3 20 4 30 5 6 7 40 8 9 10 60 80 100 20 150 30 200 300 Q [US G PM] 40 50 60 Q [m³/h] TM00 9582 5106 10 5 UP, UPS Series 200 2 Product overview Performance range, UP pumps The curves show maximum performance curves for the UP range: • dual-voltage pumps • single-speed pumps. H [m] H [ft] UP 60 Hz 40 10 9 30 8 43-110 7 43-70 6 20 53-46 5 53-45 15 4 3 10 8 2 6 5 4 15 20 30 40 60 80 100 150 Q [US GPM] 3 4 5 6 7 8 9 10 20 30 Q [m³/h] 6 TM02 5598 4706 10 UP, UPS Series 200 3 Product range 3. Product range UPS range Voltage [V] Poles Pump type UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS UPS 32-40 F 32-80 F 32-160 F 40-40 F 40-80/2 F 40-80/4 F 40-160 F 40-240 F 50-40 F 50-80/2 F 50-80/4 F 50-160 F 50-240 F 53-55/57 F 75-69 F 80-40 F 80-80 F 80-160 F 100-40 F 1 x 115 1 x 230 3 x 208-230 3 x 460 3 x 575 2 4 ● ● ● ● ● ● ● — ● ● ● — — ● — — — — — ● ● ● ● ● ● ● ● ● ● ● ● — ● ● — — — — ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● — ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● ● — ● ● — ● ● — ● — ● ● — ● — ● ● ● ● — — ● — ● — — ● — ● — — ● — ● — — — — ● ● — ● Canada only UP range Voltage [V] Poles Pump type UP UP UP UP 1 x 115/230 V 2 4 ● ● ● ● ● ● ● ● — — — — 43-70 F 43-110 F 53-45 F 53-46 F Pump overview Model UP 43-70 F UP 43-110 F UP 53-45 F UP 53-46 F UPS 32-40/4 UPS 32-80/2 UPS 32-160/2 UPS 40-40/4 UPS 40-80/2 UPS 40-80/4 UPS 40-160/2 UPS 40-240/2 UPS 50-40/4 UPS 50-80/4 UPS 50-80/2 UPS 50-160/2 UPS 50-240/2 UPS 53-55/57 F UPS 75-69 F UPS 80-40/4 UPS 80-80/4 UPS 80-160/2 UPS 100-40/4 Flow [US gpm] Head [ft] Ph Max. [rpm] Flange 15-100 15-105 15-100 15-105 9-52 9-67 9-76 13-85 13-105 13-120 13-110 13-130 20-125 20-160 20-150 20-170 20-180 20-150 20-170 30-200 30-260 30-275 30-270 1-23 1-37 1-23 1-37 1-11 1-25 1-45 1-11 1-30 1-25 1-46 1-62 1-12 1-24 1-30 1-46 1-62 1-30 1-46 1-13 1-25 1-49 1-12 1 1 1 1 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 1-3 3 1-3 1-3 3 3 3 3 3450 3450 3450 3450 1750 3450 3450 1750 3450 1750 3450 3450 1750 1750 3450 3450 3450 3450 3450 1750 1750 3450 1750 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes 2", 2.5", 3" non ANSI 4 bolt w/ (4) 0.63" dia. holes 2", 2.5", 3" non ANSI 4 bolt w/ (4) 0.63" dia. holes 1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes 1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes 2", 2.5", 3" non ANSI 4 bolt w/ (4) 0.56" dia. holes 3" ANSI 125# R.F. 3" ANSI 125# R.F. 3" ANSI 125# R.F. 3" ANSI 125# R.F. 4" ANSI 125# R.F. Flange type GF 40/43 GF 40/43 GF 53 GF 53 GF 15/26 GF 15/26 GF 40/43 GF 40/43 GF 40/43 GF 40/43 GF 40/43 GF 40/43 GF 50 GF 50 GF 50 GF 50 GF 50 GF 53 GF 80 GF 80 GF 80 GF 80 GF 100 7 UP, UPS Series 200 4 Cross-reference guide 4. Cross-reference guide Armstrong, B&G and TACO to Grundfos Manufacturer Armstrong TACO Port-to-port length [in] Flange size [in] ARMflo E21 8.50 1.50 UP43-110F 8.50 1.50 ARMflo E23 8.50 1.50 UP43-110F 8.50 1.50 S 45 10.00 2.50, 3 UP53-45F 9.88 2.00, 2.50, 3.00 S 46 10.00 2.50, 3 UP53-46F 9.88 2.00, 2.50, 3.00 S 55 12.00 3.00 UPS53-55/57F 11.88 2.00, 2.50, 3.00 S 57 12.00 3.00 UPS53-55/57F 11.88 2.00, 2.50, 3.00 S 69 14.25 3.00 UPS75-69F 14.00 2.00, 2.50, 3.00 H51 11.50 1.00 UPS32-80/2 11.00 0.75 to 1.50 H52 11.50 1.00 UPS32-80 11.00 0.75 to 1.50 H53 11.50 1.50 UPS40-160/2 11.50 1.50 H54 11.50 2.00 UPS50-80/2 11.50 2.00 H63 13.50 1.50 UPS32-160/2 13.50 1.50 H64 13.50 1.50 UPS32-160/2 13.50 1.50 H65 13.50 1.50 UPS40-240/2 13.50 1.50 H66 14.00 2.00 UPS50-160/2 14.00 2.00 H67 14.00 2.00 UPS50-160/2 14.00 2.00 H68 14.00 2.00 UPS50-240/2 14.00 2.00 1050 1B (0.25 Hp) 11.50 1.00 UPS32-80/2 11.00 0.75 to 1.50 1050 1-1/4B (0.25 Hp) 11.50 1.25 UPS32-80/2 11.00 0.75 to 1.50 1050 1-1/2B (0.25 Hp) 11.50 1.50 UPS32-80/2 11.00 0.75 to 1.50 1050 2B (0.33 Hp) 11.50 2.00 UPS50-80/4 11.50 2.00 1050 2B (0.50 Hp) 11.50 2.00 UPS50-80/4 11.50 2.00 1050 2B (0.75 Hp) 11.50 2.00 UPS50-80/4 11.50 2.00 1060 1-1/2 D (0.50 Hp) 13.50 1.50 UPS32-160/2 13.50 1.50 1060 1-1/2 D (0.75 Hp) 13.50 1.50 UPS32-160/2 13.50 1.50 1060 1-1/2 D (1.50 Hp) 13.50 1.50 UPS40-240/2 13.50 1.50 1060 2D (0.75 Hp) 14.00 2.00 UPS50-160/2 14.00 2.00 1060 2D (1.00 Hp) 14.00 2.00 UPS50-160/2 14.00 2.00 1060 2D (1.50 Hp) 14.00 2.00 UPS50-160/2 14.00 2.00 1060 2D (2.00 Hp) 14.00 2.00 UPS50-240/2 14.00 2.00 120 11.00 2.00 UPS32-40/4 11.00 0.75 to 1.50 131 13.63 3.00 UP53-45F 10.00 2.00, 2.50, 3.00 133 13.63 3.00 UPS53-55/57 11.88 2.00, 2.50, 3.00 1600 10.25 1.50 UPS32-80/2 11.00 1.50 1610 10.25 1.50 UPS32-80/2 11.00 1.50 1612 13.50 1.50 UPS32-160/2 13.50 1.50 1614 13.50 1.50 UPS32-160/2 13.50 1.50 1616 14.50 2.00 UPS40-240/2 13.50 1.50 1630 13.50 2.00 UPS50-80/4 11.50 2.00 1632 13.50 2.00 UPS50-160/2 14.00 2.00 1634 13.50 2.00 UPS50-160/2 14.00 2.00 1636 16.50 2.00 UPS50-240/2 14.00 2.00 1638 16.50 2.00 UPS50-240/2 14.00 2.00 Model Grundfos model Port-to-port length [in] Flange size [in] Bronze version to be used in open systems. Replacement model requires piping and/or flange modification. Disclaimer: This cross-reference is a guide only. Use individual technical data sheets for correct comparison. 8 UP, UPS Series 200 B&G Model Port-to-port length [in] Flange size [in] 2-1/2" 10.00 2.50 LD3 10.00 HD3 Port-to-port length [in] Flange size [in] UP53-45F 9.88 2.00, 2.50, 3.00 3.00 UP53-45F 9.88 2.00, 2.50, 3.00 10.00 3.00 UP53-46F 9.88 2.00, 2.50, 3.00 PD-35 12.00 3.00 UPS53-55/57F 11.88 2.00, 2.50, 3.00 PD-37 12.00 3.00 UPS53-55/57F 11.88 2.00, 2.50, 3.00 PD-38 14.50 3.00 UPS75-69F 14.00 2.00, 2.50, 3.00 PD-40 14.50 3.00 UPS50-160/2 14.00 2.00 601 11.00 1.00 UPS32-80/2 11.00 0.75 to 1.50 602 11.00 1.00 UPS32-80/2 11.00 0.75 to 1.50 603 11.00 1.00 UPS50-80/2 11.50 2.00 604 11.00 1.25 UPS32-80/2 11.00 0.75 to 1.50 609 11.50 1.50 UPS40-160/2 11.50 1.50 610 11.50 2.00 UPS50-80/4 11.50 2.00 621 13.50 2.00 UPS40-80/4 13.50 1.50 614 13.50 1.50 UPS40-240/2 13.50 1.50 615 13.50 2.00 UPS50-160/2 14.00 2.00 616 13.50 2.00 UPS50-160/2 14.00 2.00 622 13.50 1.50 UPS32-160/2 13.50 1.50 623 13.50 1.50 UPS40-240/2 13.50 1.50 617 13.50 1.50 UPS40-240/2 13.50 1.50 624 14.00 2.00 UPS50-160/2 14.00 2.00 625 14.00 2.00 UPS50-240/2 14.00 2.00 60-11 11.00 1.25 UPS32-80/2 11.00 0.75 to 1.50 60-13 11.50 1.50 UPS40-160/2 11.50 1.50 60-14 11.50 2.00 UPS50-80/2 11.50 2.00 60-15 13.50 1.50 UPS32-160/2 13.50 1.50 60-16 13.50 1.50 UPS32-160/2 13.50 1.50 60-17 13.50 1.50 UPS40-240/2 13.50 1.50 60-19 14.00 2.00 UPS50-160/2 14.00 2.00 60-20 14.00 2.00 UPS50-160/2 14.00 2.00 60-21 14.00 2.00 UPS50-240/2 14.00 2.00 Grundfos model Cross-reference guide Manufacturer 4 Bronze version to be used in open systems. Replacement model requires piping and/or flange modification. Disclaimer: This cross-reference is a guide only. Use individual technical data sheets for correct comparison. 9 UP, UPS Series 200 5 Construction 5. Construction Construction TM03 7880 5106 UP(S) Series 200 pumps are of the canned rotor type, i.e. pump and motor form an integral unit without shaft seal and with only two gaskets for sealing. The bearings are lubricated by the pumped liquid. Attention has been focused on using as few materials as possible, and the use of materials that might cause problems in connection with disposal have been omitted. Features: • UPS motors are two- or three-speed motors. UP motors are single-speed dual-voltage motors. • Stainless steel rotor can, bearing plate and rotor cladding. • Stator housing in aluminum alloy. • Cast iron or bronze pump housing. • Stator with built-in thermal overload switch. Fig. 2 10 Exploded view of a UP(S) Series 200 pump UP, UPS Series 200 5 Pos. Description Material 1 Terminal box 2 Inspection screw Brass with nickel 3 Nameplate Composite PA66 AISI/ASTM Composite PA66 Pos. Description 9 10 Material Thrust bearing Carbon MY 106 Bearing plate Stainless steel Inner bearing ring Aluminium oxide/SiC AISI/ASTM AISI 304 Stator housing Aluminium AlSi10Cu2 11 Stop ring Stainless steel Stator windings Copper wire 12 Split cone Stainless steel AISI 303 Stator caps Composite PETP 13 Impeller Stainless steel AISI 304 5 Cheese-head screw Steel 8.8 14 Nut Stainless steel AISI 303 6 O-rings EPDM rubber 15 Neck ring Stainless steel/PTFE AISI 304 Outer bearing ring Aluminium oxide/SiC Rotor can Stainless steel AISI 304 16 Pump housing Shaft (cast-iron pumps) Shaft (bronze pumps) Stainless steel AISI 303 AISI 316 17 Anti-friction ring PTFE Rotor cladding Stainless steel AISI 304 18 Splash protector Stainless steel Bearing Tungsten carbide 4 7 8 Construction Material specification Cast iron EN-GJL-250 Bronze CuSn10, DIN 1705 ASTM B505 and B271 AISI 303 TM02 1397 0907 Sectional drawing Fig. 3 Sectional view 11 UP, UPS Series 200 5 Construction Motor Rotor can The motor, pos. 4, is a 2- or 4-pole, asynchronous squirrel-cage motor. As the motor is cooled by the pumped liquid, the noise level is very low. The rotor can (pos. 7) is made of drawn steel sheet and fitted with an inspection screw directly at the top. There is an O-ring seal between the inspection screw and the rotor can. For reasons of safety, the hole for the inspection screw will deflect a possible jet of liquid if the inspection screw is removed. The outer radial bearing is fitted into the top of the rotor can. Stator housing TM02 1398 1101 Pressure die-cast aluminum stator housing can be turned to change the position of the terminal box. The stator housing has eight drain holes to enable condensed water to escape. The vent hole under the terminal box allows the water to evaporate from the stator. The drain holes must point downwards. The permissible terminal box positions are shown in the drawing below. The positions apply to both vertical and horizontal mounting. Fig. 4 Possible terminal box positions Note: The terminal box must only be turned to the above positions. The drawing below shows the standard box position. Shaft with rotor The shaft (pos. 8) is made of stainless steel and equipped with two tungsten carbide bearings. To further improve the internal circulation of the pumped liquid in the rotor can, the shaft of 4-pole motors is fitted with a small rotor impeller. The rotor is made of soft-annealed iron lamination and provided with copper or brass bars. The short-circuit rings are made of copper. The rotor is encapsulated in a thin stainless steel cladding and dynamically balanced. The thrust bearing is secured to the shaft in a spherically flexible suspension. TM03 2260 4005 Bearing plate Fig. 5 Standard terminal box position The nameplate can be turned in steps of 45°. The positions of the terminal box and the nameplate are changed as described above. The stator wires are self-bonding. The wires and the terminal box are connected by a terminal plug. The stator incorporates a thermal overload switch for protection of the motor if the winding temperature becomes too high. 12 The bearing plate (pos. 10) is made of stainless steel. The inner radial bearing is pressed into the bearing plate, ground and honed. The relatively large bearing plate surface means that motor heat is effectively carried away by the pumped liquid. Impeller The stainless steel impeller (pos. 13) is of the radial type with curved blades. It is secured to the shaft by a split cone and nut (left-hand thread). Pump housing The pump housing (pos. 16) is available in cast iron or bronze. All pump housings are flanged for the individual markets. See also section 4. Cross-reference guide on page 8 and section 5. Construction on page 10 concerning flanges and port-to-port lengths. The pump housing is of the in-line type. A stainless steel/PTFE neck ring minimizes the recirculation and improves pump efficiency. The bottom of the housing has threaded holes for fastening to a baseplate. UP, UPS Series 200 6 Pumped liquids Other technical data CAUTION: This pump is intended for use with water only. Grundfos UP(S) pumps can be used to circulate • Potable hot water • Water for hydronic heating • Water/glycol mixtures up to 50/50 • Cooling water. In domestic hot-water systems it is advisable to use a bronze pump (UP(S) model) only for water with a degree of hardness lower than 14 grains per gallon of hardness. For water with a higher degree of hardness, a direct coupled TP pump is recommended. If the pump is installed in a heating system, the water should meet the requirements of accepted standards on water quality in heating systems. In water/glycol mixtures, in order to prevent the glycol from degrading, temperatures above those for which the fluid is rated should be avoided and time spent at high temperatures minimized. It is also important that the system is cleaned and flushed prior to the installation of the glycol mixture. In order to avoid problems with corrosion or precipitation, the glycol fluids should be checked and maintained regularly. If further dilution of the supplied glycol is required, follow the requirements of the supplier of the glycol. The pump is lubricated and cooled by the liquid being pumped. Therefore, the pumped liquid must always be allowed to circulate through the pump. Extended periods without circulation will cause premature wear to the bearings and excessive motor heat. The pumped liquid must also meet the following requirements. The pumping of liquids with densities or kinematic viscosities higher than those of water will cause – a considerable pressure drop – a drop in the hydraulic performance – a rise in the power consumption. In these situations, contact Grundfos for assistance. Relative humidity: Max. 95 %. Sound-pressure level: The sound-pressure level of the pump is lower than 41 dB(A) (reference: 20 mPa). Max. working pressure: 145 psi (10 bar). Approvals: See the pump nameplate. Operating conditions 6. Operating conditions Inlet pressure To avoid cavitation noise, the following minimum pressures are required at the pump suction flange: Liquid temperature UP(S) model UPS 32-40 167 °F (75 °C) 194 °F (90 °C) 230 °F (110 °C) [psi] [ft] [psi] [ft] [psi] [ft] 0.7 1.6 2.2 5.1 21.0 48.5 UPS 32-80 0.7 1.6 5.1 11.8 23.9 55.2 UPS 32-160 11.6 26.8 16.0 37.0 34.1 78.8 UPSD 40-40 0.7 1.6 4.4 10.2 23.2 53.6 UPS 40-80/4 0.7 1.6 1.5 3.5 18.1 41.8 UPS40-80/2 6.5 15.0 10.9 25.2 29.0 67.0 UPS 40-160 5.1 11.8 9.4 21.7 27.6 63.8 UPS 40-240 11.6 26.8 16.0 37.0 34.1 78.8 UPS 50-40 0.7 1.6 2.9 6.6 21.8 50.4 UPS 50-80/4 0.7 1.6 4.4 10.2 23.2 53.6 UPS 50-80/2 4.4 10.2 8.7 20.1 26.8 61.9 UPS 50-160 11.6 26.8 16.0 37.0 34.1 78.8 UPS 50-240 10.2 23.6 14.5 33.5 32.6 75.1 UPS 53-55/57 4.4 10.2 8.7 20.1 26.8 61.9 UPS 75-69 11.6 26.8 16.0 37.0 34.1 78.8 UPS 80-40 11.6 26.8 16.0 37.0 34.1 78.8 UPS 80-80 14.5 33.5 18.9 43.7 37.0 85.5 UPS 80-160 21.8 50.4 26.1 60.3 43.5 100.5 UPS 100-40 27.6 63.8 31.9 73.7 50.0 115.5 UP 43-70F 0.7 1.6 4.8 11.0 15.4 35.6 UP 43-110 3.6 8.4 8.2 19.0 18.9 43.7 UP 53-45 2.9 6.6 7.5 17.3 18.1 41.8 UP 53-46 1.1 2.5 5.8 13.4 16.4 37.9 Temperature limits Ambient air temperature 32 °F to 104 °F (0 °C to 40 °C) Fluid temperature, open systems 140 °F (60 °C). Fluid temperature, closed systems UPS pumps: 248 °F (120 °C). UP pumps: 230 °F (110 °C). 13 UP, UPS Series 200 6 Operating conditions Electrical data Insulation class Supply voltage and frequency Pump type UPS: 115 V, 230 V, 1-phase 60 Hz, 208-230 V, 460 V, 575 V, 3 phase 60 Hz. UP: 115 V, 230V, 1-phase 60 Hz, 460 V, 575 V, 3-phase 60Hz. Back-up fuse: Max. 10 A. Enclosure class: IP 44 indoor use only. Supply voltage tolerances The motors meet the requirements to temperature rise at - 6 / +6 %. Furthermore, the motors have been tested at -10 / +10 % of the voltage range. During these tests, the motors operate without problems and without being thermally cut out. The motor voltage tolerances are intended for power supply voltage variations. They should not be used for running motors at other voltages than those stated on the name plates. Variable speed applications All 3 x 460 V, 3 x 575 V and 3-speed 3 x 208-230 V pumps with standard module are suitable for frequency converter applications. Please refer to section Variable frequency drive operation on page 17 for further information. Insulation class UPS 1 x 115 V 1 x 230 V 3 x 208-230 V 3 x 460 V 3 x 575 V 32-40 F F 32-80 F F 32-160 H F 40-40 F F 40-80/4 H H 40-80/2 F F 40-160 H H 40-240 H H 50-40 F F 50-80/4 H H 50-80/2 H F 50-160 H H 50-240 — H 53-55/57 H F 75-69 H H 80-40 — H 80-80 — H 80-160 — H 100-40 — H Pump type Insulation class UP Terminal box TM00 9133 4596 Indicator lights and speed indication Fig. 6 F 43-110 F 53-45 F 53-46 F Thermal overload switch Voltage 250 V AC Current cos phi = 1.0: 2.5 A cos phi = 0.6: 1.6 A Terminal box The terminal box with cover (pos. 1) is made from black composite material. The terminal box is equipped with: • 1 x 1½" NPT screwed cable entry for mains connection, to be fitted during installation. • 1 x M16 screwed cable entry for capacitor connection (only single-phase pumps) • 2 x indicator lights (single-phase pumps with standard module have just one). Note: UPS pumps only. • window for indication of speed. Note: UPS pumps only. The terminal box is fastened to the stator housing with screws and connected to the stator by a terminal plug. 14 1 x 115/230 V 43-70 Start/stop input (relay module) External potential-free contact. Maximum load: 250 V, 1.5 mA. Minimum load: 100 V, 0.5 mA. Operating/fault signal output (relay module) Internal potential-free changeover contact. Maximum load: 250 V, 2 A, AC. Minimum load: 5 V, 100 mA, DC. UP, UPS Series 200 7 Functions 7. Functions Functions Additional terminal box options UPS terminal box includes Pump model UPS 32 UPS 40 UPS 50 UPS 53-55/57 UPS 75-69 UPS 80 UPS 100 Voltage options Speed switch 1 x 115/230 ■ 3 x 208/230 ■ 3 x 460 Δ 3 x 575 Δ 1 x 115/230 ■ 3 x 208/230 ■ 3 x 460 Δ 3 x 575 Δ 1 x 115/230 ■ 3 x 208/230 ■ 3 x 460 Δ Standard module Protection module Terminal block Protection module Relay module ● ● ■ External contactor required ● ■ ■ ■ 3 3 ❑ 2 ❑ ■ ● ■ ● ● ■ ■ 3 ❑ 2 ● ■ ● ● ■ 3 x 575 Δ 1 x 115/230 ■ ■ ■ ● 1 x 230 ■ ■ ● 3 x 208/230 ■ ■ ● ● 3 ❑ 2 ❑ 2 3 3 3 2 3 x 460 Δ ■ ❑ Δ ■ ❑ 1 x 230 ■ 3 x 208/230 ■ 3 x 460 ■ 3 x 575 Δ ● ■ ● ■ 1 x 115/230 ■ 3 x 208/230 ■ 3 x 460 Δ ■ ■ 3 x 575 Δ 1 x 115/230 ■ 3 x 208/230 ■ 3 x 460 Δ 3 x 575 Δ UP 43-70 1 x 115/230 ● ■ ■ ■ 3 3 ❑ 2 ● ● ● 3 3 ❑ 2 ❑ 2 ● ■ ■ ● ■ ● 2 3 ● ■ 2 3 3 x 575 ■ 2 3 ❑ ■ Number of speeds 3 3 ❑ 2 ■ ❑ 2 ■ ❑ 1 UP 43-110 1 x 115 ■ ❑ 1 UP 53-45 1 x 115/230 ■ ❑ 1 UP 53-46 1 x 115/230 ■ ❑ 1 Canada only Standard The speed is changed by reconfiguring the jumper positions, located in the terminal box. Optional ❑ Required External contactor is not required when using the Protection Module option. Standard module: Indicator lights with no motor protection. For motor protection, use Protection Module for 1 x 115/230 V and 3 x 208/230 V units or use an external contactor. Protection module: Indicator lights with built-in motor protection. Connect directly to line voltage. Note: Pumps with protection module must not be connected to a variable frequency drive (VFD). Relay module: Indicator lights with signal output for external control or fault indication (1 x 115/230 V or 3 x 208/230 V units only). External contactor required: Pump must be connected to line voltage via an external contactor. The contactor is to be connected to the pump’s build-in thermal overload terminals. The speed is changed by orientation of the internal jumpers. 15 UP, UPS Series 200 7 Functions Description of functions Indicator lights and speed indication TM00 9747 0602 Three-speed pumps TM00 9235 3802 Speed switch Fig. 7 3 x 208/230V terminal box Fig. 10 UPS Series 200 pump with terminal box mounted Two-speed pumps All UPS pumps with 3 x 460 V & 575 V terminal boxes are fitted with a special two-speed terminal block. By means of the speed switch, the pump performance can be adjusted to suit the system in question. For 1 x 115/230 V and 3 x 208/230 V three-speed pumps only. The module is located inside the terminal box. It has three positions: L3 P2 P1 SPEED Fig. 8 Speed switch module T6 T1 Fig. 11 3 x 460 V & 575 V terminal box The speed is changed by changing the jumper positions. Single-phase pumps Three-phase pumps 1 approx. 60% approx. 70% The pump must be connected to the mains via an external contactor. The contactor is to be connected to the pump’s built-in thermal overload switch (terminals P1 and P2) to protect the pump against overheating at both speeds. 2 approx. 80% approx. 85% Speed selection (two-speed, 3 x 460 V and 575 V) 3 100% 100% Speed in % of maximum speed Switch position The speed setting in the terminal box can be changed to two positions. The speed in the two positions appears in the table below Note: UP pumps runs at 100%. Change to a lower speed enables considerable reduction in energy consumption and less noise in the system. 2 Q Fig. 9 H H 1 3 Q Pump performance at the three speeds Q TM00 9247 4595 H 16 T2 Jumpers L1 L2 T4 SPEED TM00 9583 4996 SPEED T3 TM02 5740 3202 T5 Speed step Speed in % of maximum 1 Approx. 75% 2 100% Single-speed pumps UP pumps (1 x 115/230 V) UP pumps are single-speed pumps with a 1 x 115 V/230 V terminal box with a dual-voltage terminal block. See fig. 12. UP, UPS Series 200 7 Functions Single-phase pumps Single-phase pumps incorporate a green indicator light only: Jumpers L Indicator light N On The electricity supply has been switched on. Off The electricity supply has been switched off, or the pump has been cut out by the thermal overload switch. TM02 5761 3902 P2 P1 T1 T5 T3 T4 T2 T8 Fig. 12 1 x 115/230 V terminal box Three-phase pumps Three-phase pumps have a green and a red indicator light: Indicator lights The voltage is changed by changing the orientation of the jumpers. See fig. 12. The pump must be connected to the power supply via an external switch. The UP pumps are equipped with a built-in, automatically resetting terminal overload switch, protecting the pump at both 115 V and 230 V. The built-in terminal overload switch (terminals P1 and P2) can optionally be connected to external overload protection. Pumps with standard module TM00 9237 4597 Standard module Speed switch Description Fig. 13 Terminal box with standard module The standard module is standard in three-phase pumps with three speeds and forms connection between supply terminals and motor. The pumps with standard module must be connected to the power supply via an external contactor. For motor protection the contactor is to be connected to the pump’s built-in thermal overload switch to protect the pump against overheating at all three speeds. Standard module indicator lights Description Green Red Off Off The electricity supply has been switched off, or the pump has been cut out by the thermal overload switch. On Off The electricity supply has been switched on. On On The electricity supply has been switched on. The direction of rotation is wrong. Variable frequency drive operation All 3 x 460 V, 3 x 575 V and 3-speed 3 x 208-230 V pumps with standard module are suitable for variable frequency drive (VFD) applications. Please note the following: • Even if the red indicator light is on, the pump is operating normally. • Pumps fitted with other modules than the standard module must not be connected to a VFD. • Depending on the VFD type, this may cause increased acoustic noise from the motor. Furthermore, it may cause the motor to be exposed to detrimental voltage peaks. • The motor must be protected against voltage peaks higher than 650 V between the motor terminals. Acoustic noise and detrimental voltage peaks can be reduced by fitting an LC filter between the VFD and the motor. Pumps with protection module The protection module is standard for single-phase UPS pumps and available for 3 x 208-230 V UPS pump models only as an option. When fitted with a protection module, the pump can be connected directly to the power supply switch as it will be protected by the built-in overload protection. The protection module incorporates two indicator lights. The indicator lights on pumps with standard module show whether the pump is live, or whether the phase sequence of three-phase pumps is wrong. 17 UP, UPS Series 200 7 Functions Protection module indicator lights Indicator lights Description Indicator lights Description Green Red Off Off On Off On On Off On The pump has been stopped. The electricity supply has been switched off. The pump is operating. Three-phase pumps only: The pump is operating, but the direction of rotation is wrong. The pump has been cut out by the thermal overload switch. Green Red Off Off On On Relay module indicator lights The relay module indicator lights provides detailed operating and fault indications. All pumps with relay module incorporate a green and a red indicator light. Functions, see table in Signal output of relay module. Signal output of relay module The relay module has a signal output for external operating or fault indication. By means of the selector switch, the signal output can be set to activation during operation or fault. Operation: The output functions as operating indication between terminals 2 and 3. Fault: The output functions as fault indication between terminals 1 and 3. Off On Flashing Off Flashing Fault 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C On The pump has been stopped. The electricity supply has been switched off, or a phase is missing. The pump is operating. On Pumps with relay module The relay module is available for UPS pumps as an option for 1 x 115/230 V and 3 x 208-230 V units. The module enables direct connection of the pump to an external power supply switch. Furthermore, the module has a signal output for external operating or fault indication. By means of a selector switch the output can be set to activation during operation or fault. The pump is connected directly to the power supply as the pump incorporates overload protection at all three speeds. Note: Pumps with relay module must not be connected to a variable frequency drive (VFD). If the pump has been cut out by the thermal overload switch, it will restart automatically when it has cooled to normal temperature, provided the external on/off contact is closed. Note: If the thermal overload switch has cut out the pump three times within a short time, the relay must be reset manually by switching off the electricity supply. Operation Off Note: Pumps with protection module must not be connected to a variable frequency drive. 18 Signal output set to 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C 1 2 3 NC NO C Only three-phase pumps: The pump is operating, but with wrong direction of rotation. The pump has been cut out by the thermal overload switch. The pump has been stopped by an external on/off switch. The pump is or has been cut out by the thermal overload switch, and it has been stopped by an external on/off switch. Two pumps plumbed in parallel Operating modes Both pumps must be fitted with a relay module. In addition to the signal functions, the signal output of the relay module for two pumps in parallel can be used for controlling the operating mode of pump 1 and 2. It is possible to choose between three operating modes: 1. Alternating operation. The pumps operate alternately as duty and standby pump, respectively. Changeover takes place every 24 hours. If the duty pump is cut out due to a fault, the standby pump will automatically start. During changeover both pumps will be running for a short period to ensure a low-noise changeover. 2. Standby operation. The pumps operate continuously as duty and standby pump, respectively. If the duty pump is cut out due to a fault, the standby pump will automatically start at a signal from the output of the duty pump. The sequence can be changed to make the standby pump operate as duty pump. 3. Single-pump operation. The pumps run independently without communicating with each other. UP, UPS Series 200 8 Technical data 8. Technical data Technical data, UPS Model Cast iron product number Bronze product number 96402694 96402699 Max. Hp Speed 3 Ph Voltage 115 1 96402695 UPS 32-40/4 96402696 96402697 96402698 96402708 96402700 96402701 230 0.33 96402702 208-230 3 96402703 460 575 96402713 115 1 96402709 UPS 32-80/2 96402710 96402711 96402712 96402730 96402714 96402715 230 0.50 96402716 208-230 3 96402717 460 575 96402739 115 1 96402733 UPS 32-160/2 96402736 96402737 96402738 96402740 96402741 230 0.75 96402742 96402743 208-230 3 460 575 Speed I-MAX. [Amps] P-MAX. [Watts] Istart [Amps] 3 1.08 120 2.10 2 1.04 100 2.02 1 0.95 85 1.85 3 0.54 120 1.00 2 0.52 100 0.96 1 0.47 85 0.87 3 0.56 115 1.60 2 0.26 75 0.74 0.69 1 0.24 65 3 0.28 115 0.82 2 0.13 75 0.38 ▲ ▲ ▲ ▲ 3 0.22 115 0.66 0.30 2 0.10 75 ▲ ▲ ▲ ▲ 3 2.66 280 7.10 2 2.50 260 6.67 1 2.50 250 6.67 3 1.34 280 3.80 2 1.26 260 3.29 1 1.26 250 3.29 3 1.10 280 5.00 2 0.72 235 3.93 1 0.58 195 3.16 3 0.55 280 2.80 2 0.36 235 1.96 ▲ ▲ ▲ ▲ 3 0.44 280 2.20 1.60 2 0.29 235 ▲ ▲ ▲ ▲ 3 5.80 625 14.60 2 5.80 600 14.60 1 5.50 555 13.84 3 2.90 625 6.70 2 2.90 600 6.70 1 2.75 555 6.35 3 1.96 600 9.30 2 1.25 430 5.93 1 1.12 380 5.31 3 0.98 600 4.70 3.02 2 0.63 430 ▲ ▲ ▲ ▲ 3 0.78 600 3.76 2 0.50 430 2.40 ▲ ▲ ▲ ▲ ▲All 3-phase, 460V and 575V pumps are 2-speed only. Canada only 19 UP, UPS Series 200 8 Technical data Model Cast iron product number Bronze product number Max. Hp Speed 3 Ph Voltage 96402748 96402753 115 1 96402749 UPS 40-40/4 96402750 96402751 96402752 96404948 96402754 96402755 230 0.33 96402756 208-230 3 96402757 460 575 96404953 115 1 96404949 UPS 40-80/4 96404950 96404951 96404952 96402762 96404954 96404955 230 0.50 96404956 208-230 3 96404957 460 575 96402767 115 1 96402763 UPS 40-80/2 96402764 96402765 96402766 ▲ 96402768 96402769 230 0.75 96402770 96402771 All 3-phase, 460V and 575V pumps are 2-speed only. Canada only 20 208-230 3 460 575 Speed I-MAX. [Amps] P-MAX. [Watts] Istart [Amps] 3 1.60 170 3.10 2 1.48 150 2.87 1 1.34 125 2.60 3 0.80 170 1.50 2 0.74 150 1.39 1 0.66 125 1.24 3 0.88 260 2.50 2 0.42 120 1.19 1 0.36 100 1.02 3 0.44 260 1.30 0.62 2 0.21 120 ▲ ▲ ▲ ▲ 3 0.33 260 1.04 0.50 2 0.17 120 ▲ ▲ ▲ ▲ 3 5.50 565 9.50 2 5.15 485 8.90 1 4.30 410 7.43 3 2.75 565 4.70 2 2.60 485 4.44 1 2.15 410 3.67 3 1.98 550 7.10 2 1.20 370 4.30 1 1.00 305 3.59 3 0.99 550 4.70 2 0.60 370 4.44 ▲ ▲ ▲ ▲ 3 0.78 550 3.76 3.55 2 0.48 370 ▲ ▲ ▲ ▲ 3 4.45 480 11.00 2 4.40 450 10.88 1 4.40 440 10.88 3 2.24 480 5.60 2 2.20 450 5.50 1 2.18 440 5.45 3 1.45 440 7.40 2 0.94 320 4.80 1 0.86 290 4.39 3 0.73 440 3.70 2 0.47 320 2.38 ▲ ▲ ▲ ▲ 3 0.58 440 2.96 2 0.38 320 1.90 ▲ ▲ ▲ ▲ UP, UPS Series 200 Cast iron product number Bronze product number 96402782 96402787 Max. Hp Speed 3 Ph Voltage 115 1 96402783 UPS 40-160/2 96402784 96402785 96402786 96402797 96402798 96402788 96402789 230 0.75 96402790 208-230 3 96402791 460 575 96402804 1 96402805 230 208-230 1.50 UPS 40-240/2 96402799 96402801 96402814 96402807 3 96402809 460 575 96402819 115 1 96402815 UPS 50-40/4 96402816 96402817 96402818 96402820 96402821 230 0.33 96402822 96402823 208-230 3 460 575 Speed I-MAX. [Amps] P-MAX. [Watts] Istart [Amps] 3 8.40 890 18.60 2 7.45 760 16.50 1 6.95 690 15.39 3 4.20 890 9.30 2 3.75 760 8.30 1 3.45 690 7.64 3 2.50 800 12.40 2 1.75 570 8.68 1 1.55 500 7.69 3 1.25 800 6.20 4.36 2 0.88 570 ▲ ▲ ▲ ▲ 3 1.00 800 4.96 3.50 2 0.70 570 ▲ ▲ ▲ ▲ 3 6.20 1350 11.80 2 5.55 1200 10.56 1 5.15 1100 9.80 3 4.50 1440 23.80 2 3.25 1100 17.19 1 2.95 990 15.60 3 2.25 1440 11.60 2 1.63 1100 8.40 ▲ ▲ ▲ ▲ 3 1.80 1440 9.28 6.72 2 1.30 1100 ▲ ▲ ▲ ▲ 3 2.66 285 5.20 2 2.60 244 5.08 1 2.20 204 4.30 3 1.32 285 2.60 2 1.30 244 2.56 1 1.10 204 2.17 3 1.40 270 4.60 2 0.66 170 2.17 1 0.54 150 1.77 3 0.70 270 2.30 2 0.33 170 1.08 ▲ ▲ ▲ ▲ 3 0.56 270 1.84 2 0.26 170 0.86 ▲ ▲ ▲ ▲ Technical data Model 8 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. Canada only 21 UP, UPS Series 200 8 Technical data Model Cast iron product number Bronze product number 96404958 96404963 Max. Hp Speed 3 Ph Voltage 115 1 96404959 UPS 50-80/4 96404960 96404961 96404962 96402834 96404964 96404965 230 0.75 96404966 208-230 3 96404967 460 575 96402843 115 1 96402836 UPS 50-80/2 96402838 96402840 96402842 96411613 96402860 96402844 96402845 96402862 96402882 96402883 96402884 3 96402847 460 575 96411614 1 96402866 230 208-230 96402868 3 96402870 96402885 96402886 460 575 208-230 2.00 96402887 All 3-phase, 460V and 575V pumps are 2-speed only. Canada only 22 208-230 1.50 96402861 ▲ 0.75 96402846 UPS 50-160/2 UPS 50-240/2 230 3 460 575 Speed I-MAX. [Amps] P-MAX. [Watts] Istart [Amps] 3 7.55 720 13.20 2 6.85 620 11.98 1 5.15 480 9.00 3 3.80 720 6.50 2 3.40 620 5.82 1 2.60 480 4.45 3 2.44 640 8.50 2 1.44 450 5.02 1 1.24 390 4.32 3 1.22 640 4.30 2.54 2 0.72 450 ▲ ▲ ▲ ▲ 3 0.98 640 3.44 2.00 2 0.58 450 ▲ ▲ ▲ ▲ 3 5.85 630 14.60 2 5.80 610 14.48 1 5.70 600 14.23 3 2.95 630 7.30 2 2.90 610 7.18 1 2.85 600 7.05 3 1.92 610 9.30 2 1.20 440 5.81 1 1.08 400 5.23 3 0.96 610 4.70 2 0.60 440 2.94 ▲ ▲ ▲ ▲ 3 0.77 610 3.76 2.40 2 0.48 440 ▲ ▲ ▲ ▲ 3 5.80 1250 26.50 2 5.20 1100 23.76 1 4.85 1050 22.16 3 4.00 1300 22.80 2 3.00 1000 17.10 1 2.75 950 15.68 3 2.00 1300 11.40 2 1.50 1000 8.55 ▲ ▲ ▲ ▲ 3 1.60 1300 9.12 6.84 2 1.20 1000 ▲ ▲ ▲ ▲ 3 5.80 1700 26.50 2 3.95 1300 23.10 1 3.50 1150 20.47 3 2.65 1700 15.40 2 1.98 1300 11.51 ▲ ▲ ▲ ▲ 3 2.12 1700 12.32 2 1.68 1300 9.21 ▲ ▲ ▲ ▲ UP, UPS Series 200 Cast iron product number Bronze product number 96654373 96654392 Max. Hp Speed 3 Ph Voltage 115 1 96654374 UPS 53-55/57 96654375 96654376 96654377 96654378 96654379 96654393 96654394 96654391 96402894 96402895 96402896 96402908 96402920 UPS 80-160/2 208-230 3 96654396 460 575 96654397 1 96654398 230 208-230 1.50 96654390 UPS 80-80/4 0.75 96654395 UPS 75-69 UPS 80-40/4 230 96402921 96402922 96654399 3 96654400 575 96402899 9 6402900 208-230 0.50 3 96402901 96402913 460 575 1.50 3 96402923 96402924 460 208-230 208-230 3.00 96402925 3 460 575 Speed I-MAX. [Amps] P-MAX. [Watts] Istart [Amps] 3 5.85 630 14.60 2 5.80 610 14.23 1 5.70 600 14.48 3 2.95 630 7.30 2 2.90 610 7.18 1 2.85 600 7.05 3 1.92 610 9.30 2 1.20 440 5.81 1 1.08 400 5.23 3 0.96 610 4.70 2.94 2 0.60 440 ▲ ▲ ▲ ▲ 3 0.77 610 3.76 2 0.48 440 2.40 ▲ ▲ ▲ ▲ 2 5.20 1100 23.76 1 4.85 1050 22.16 3 4.00 1300 22.80 2 3.00 1000 17.10 1 2.75 950 15.68 3 2.00 1300 11.40 2 1.50 1000 8.55 ▲ ▲ ▲ ▲ 3 1.60 1300 9.12 6.84 2 1.20 1000 ▲ ▲ ▲ ▲ 3 1.62 380 7.10 2 0.87 260 3.81 1 0.77 230 3.37 3 0.81 380 3.50 1.90 2 0.44 260 ▲ ▲ ▲ ▲ 3 0.65 380 2.80 1.52 2 0.35 260 ▲ ▲ ▲ ▲ 3 3.60 1050 11.80 2 2.08 660 6.82 1 1.72 550 5.64 3 6.35 2050 31.00 2 4.20 1550 20.50 1 4.05 1500 19.77 3 3.13 2050 15.40 10.17 2 2.10 1550 ▲ ▲ ▲ ▲ 3 2.54 2050 12.32 2 1.68 1550 8.14 ▲ ▲ ▲ ▲ Technical data Model 8 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. Canada only 23 UP, UPS Series 200 8 Technical data Model UPS 100-40/4 Cast iron product number Bronze product number 96402934 96402937 96402935 96402936 96402938 Max. Hp Speed 3 Ph Voltage 208-230 1.00 3 460 96401961 575 Speed I-MAX. [Amps] P-MAX. [Watts] Istart [Amps] 3 2.50 570 10.80 2 1.38 435 5.96 1 1.24 390 5.36 3 1.24 570 5.40 3.05 2 0.70 435 ▲ ▲ ▲ ▲ 3 1.00 570 4.32 2 0.55 435 2.44 ▲ ▲ ▲ ▲ ▲ All 3-phase, 460V and 575V pumps are 2-speed only. Canada only Technical data, UP Cast iron product number Bronze product number Hp Ph Voltage I-MAX [Amps] P-MAX [Watts] UP 43-70 96439644 — 0.50 1 115/230 3.4/1.8 400 UP 43-110 96439643 — 0.75 1 115/230 4.9/2.5 570 UP 53-45 96633576 96633578 0.50 1 115/230 3.5/1.9 360 UP 53-46 96633591 96633592 0.75 1 115/230 3.9/2.1 420 Pump type Curve conditions The guidelines listed below, apply to the performance curves in section 9. Curve charts and technical data: 1. Because of the danger of overheating, the pumps must not be used at a flow below 0.1 x Q at best efficiency point. 2. The bold parts of the curves show the recommended performance range. 3. Test liquid: Airless water. 4. The curves apply to a liquid temperature of 68 °F (20 ºC). All curves show average values and should not be used as guarantee curves. If a stated minimum performance is required, individual measurements must be made. 24 UP, UPS Series 200 9 UPS 32-40/4 1 ph, 115 V, 230 V, 60 Hz Curve charts and technical data 9. Curve charts and technical data UPS 32-40/4, 1 ph, 115 V, 230 V, 60 Hz H [ft] 12 H [m] 2 1 10 3 3 8 2 6 4 1 2 0 0 10 0 P1 [hp] P1 [W] 150 0.2 100 0.1 50 0.0 2 20 30 4 6 40 8 50 10 60 Q [US GPM] Q [m³/h] 12 60 Eta [%] 3 1 20 Eta 0 10 20 30 40 1 - 11 ft Motor: 4-pole 0.33 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 35.9 lbs (16.3 kg) Gross wt.: 43.4 lbs (19.7 kg) Shipping volume: 1.70 ft3 (0.048 m3) Net wt. bronze: 39.2 lbs (17.8 kg) Gross wt. bronze: 46.7 lbs (21.2 kg) Shipping volume bronze: 1.70 ft3 (0.048 m3) 40 2 0 9 - 52 gpm Head range: TM00 9510 0697 0 Flow range: 0 60 Q [US GPM] 50 Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 D6 B5 D7 Dimensions Model UPS 32-40/4 [in] L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 11.00 5.50 5.31 5.56 3.00 3.00 3.19 2.69 9.50 12.24 1.44 2.56 3.14 4.63 0.50 1.81 2.25 279 140 135 141 76 76 81 68 241 311 37 65 80 117 13 46 57 [mm] Product numbers M12 Connections Product number Flange size Voltage [V] Model type UPS 32-40/4 (1 ph) M Cast Iron Bronze 96402694 96402699 115 96402695 96402700 230 1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 15/26 Electrical data Max amps [A] Speed Start amps [A] P Max [Watts] 115V 230V 115V 230V 3 1.08 0.54 120 2.10 1.00 2 1.04 0.52 100 2.02 0.96 1 0.95 0.47 85 1.85 0.87 25 UPS 32-40/4 Curve charts and technical data UP, UPS Series 200 9 UPS 32-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz Flow range: 9 - 52 gpm Head range: 1 - 11 ft 3 Motor: 4-pole 0.33 Hp 2 1 Max. liquid temp (Open): +140 °F H [ft] 12 H [m] 10 3 8 2 6 4 1 2 0 0 10 0 P1 [hp] P1 [W] 150 0.2 100 0.1 50 0.0 20 2 4 30 40 6 50 8 10 60 Q [US GPM] 12 Q [m³/h] 60 Eta [%] 3 40 2 1 20 Eta 0 0 10 20 30 40 0 60 Q [US GPM] 50 +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 35.9 lbs (16.3 kg) Gross wt.: 43.4 lbs (19.7 kg) Shipping volume: 1.70 ft3 (0.048 m3) Net wt. bronze: 39.2 lbs (17.8 kg) Gross wt. bronze: 46.7 lbs (21.2 kg) Shipping volume bronze: 1.70 ft3 (0.048 m3) TM03 7904 5106 0 Max. liquid temp.: Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 D6 B5 D7 Dimensions Model UPS 32-40/4 [in] L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 11.00 5.50 5.31 5.56 3.00 3.00 3.19 2.69 9.50 12.24 1.44 2.56 3.14 4.63 0.50 1.81 2.25 279 140 135 141 76 76 81 68 241 311 37 65 80 117 13 46 57 [mm] Product numbers M12 Connections Product number Cast Iron Bronze Voltage [V] 96402696 96402701 208-230 96402697 96402702 460 96402698 96402703 575 ★ Model type UPS 32-40/4 (3 ph) M Flange size 1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 15/26 Electrical data Max amps [A] Speed 26 208-230V 460V 575V ★ 3 0.56 0.28 0.22 2 0.26 0.13 0.10 1 0.24 ▲ ▲ ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 115 1.60 0.82 0.66 75 0.74 0.38 0.30 65 0.69 ▲ ▲ UP, UPS Series 200 9 UPS 32-80/2 1 ph, 115 V, 230 V, 60 Hz H [ft] 25 H [m] 4 2 2 1 20 6 3 9 - 67 gpm Head range: 1 - 25 ft Motor: 2-pole 0.50 Hp Max. liquid temp (Open): +140 °F 15 Max. liquid temp.: +248 °F 10 Min. liquid temp.: +32 °F 5 0 0 10 0 P1 [hp] P1 [W] 300 0.4 0.3 200 0.2 100 0.1 0.0 0 0 2 20 4 30 6 40 8 50 10 60 12 70 Q [US GPM] Q [m³/h] 14 1 3 2 40 20 Eta 10 20 30 40 50 60 Eta [%] 0 70 Q [US GPM] 60 Max. system pressure: 145 psi Net wt: 35.9 lbs (16.3 kg) Gross wt.: 41.1 lbs (20 kg) Shipping volume: 1.70 ft3 (0.048 m3) Net wt. bronze: 39.2 lbs (17.8 kg) Gross wt. bronze: 47.4 lbs (21.5 kg) Shipping volume bronze: 1.70 ft3 (0.048 m3) TM00 9511 0697 0 Flow range: Curve charts and technical data UPS 32-80/2, 1 ph, 115 V, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 D6 B5 D7 Dimensions Model UPS 32-80/2 [in] L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 11.00 5.50 5.31 5.56 3.00 3.00 3.19 2.69 9.50 12.12 1.44 2.56 3.14 4.63 0.50 1.81 2.25 279 140 135 141 76 76 81 68 241 308 37 65 80 117 13 46 57 [mm] Product numbers M12 Connections Product number Model type UPS 32-80/2 (1 ph) M Flange size Voltage [V] Cast Iron Bronze 96402708 96402713 115 96402709 96402714 230 1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 15/26 Electrical data Max amps [A] Speed Start amps [A] P Max [Watts] 115V 230V 115V 230V 3 2.66 1.34 280 7.10 3.80 2 2.50 1.26 260 6.67 3.29 1 2.50 1.26 250 6.67 3.29 27 UPS 32-80/2 Curve charts and technical data UP, UPS Series 200 9 UPS 32-80/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [ft] 25 H [m] 20 6 4 2 3 2 1 9 - 67 gpm Head range: 1 - 25 ft Motor: 2-pole 0.50 Hp Max. liquid temp (Open): +140 °F 15 Max. liquid temp.: +248 °F 10 Min. liquid temp.: +32 °F 5 0 0 10 0 P1 [hp] P1 [W] 300 0.4 0.3 200 0.2 100 0.1 0.0 0 0 20 2 4 30 40 6 8 50 10 60 12 70 Q [US GPM] Q [m³/h] 14 3 2 40 1 Eta 10 20 30 40 50 60 Eta [%] 20 0 70 Q [US GPM] 60 Max. system pressure: 145 psi Net wt: 35.9 lbs (16.3 kg) Gross wt.: 41.1 lbs (20 kg) Shipping volume: 1.70 ft3 (0.048 m3) Net wt. bronze: 39.2 lbs (17.8 kg) Gross wt. bronze: 47.4 lbs (21.5 kg) Shipping volume bronze: 1.70 ft3 (0.048 m3) TM00 9494 0697 0 Flow range: Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 D6 B5 D7 Dimensions Model [in] UPS 32-80/2 L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 11.00 5.50 5.31 5.56 3.00 3.00 3.19 2.69 9.50 12.12 1.44 2.56 3.14 4.63 0.50 1.81 2.25 279 140 135 141 76 76 81 68 241 308 37 65 80 117 13 46 57 [mm] Product numbers M12 Connections Product number Cast Iron Bronze Voltage [V] 96402710 96402715 208-230 96402711 96402716 460 96402712 96402717 575 ★ Model type UPS 32-80/2 (3 ph) M Flange size 1.25" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 15/26 Electrical data Max amps [A] Speed 28 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 575V ★ 3 1.10 0.55 0.44 280 5.00 2.80 2.20 2 0.72 0.36 0.29 235 3.93 1.96 1.60 1 0.58 ▲ ▲ 195 3.16 ▲ ▲ UP, UPS Series 200 9 UPS 32-160/2 1 ph, 115 V, 230 V, 60 Hz H [ft] 50 H [m] 14 12 10 8 6 4 2 0 3 1 2 40 Flow range: 9 - 76 gpm Head range: 1 - 45 ft Motor: 2-pole 0.75 Hp Max. liquid temp (Open): +140 °F 30 Max. liquid temp.: +248 °F 20 Min. liquid temp.: +32 °F 10 0 0 P1 [hp] P1 [W] 800 1.0 600 400 0.5 200 0.0 0 0 10 20 2 4 30 6 40 8 50 60 70 80 Q [US GPM] 10 12 14 16 18 Q [m³/h] 3 2 1 Eta 10 20 30 40 50 60 70 80 Eta [%] 60 40 20 0 80 Q [US GPM] 145 psi Net wt: 37.0 lbs (16.8 kg) Gross wt.: 45.2 lbs (20.5 kg) Shipping volume: 1.70 ft3 (0.048 m3) Net wt. bronze: 37.7 lbs (17.1 kg) Gross wt. bronze: 45.9 lbs (20.8 kg) Shipping volume bronze: 1.70 ft3 (0.048 m3) TTM00 9512 0697 0 Max. system pressure: Curve charts and technical data UPS 32-160/2, 1 ph, 115 V, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 B5 D6 D7 Dimensions Model UPS 32-160/2 [in] L1 L3 B1 B2 B4 B5 B7 H1 13.50 5.50 5.31 5.56 3.00 3.00 3.19 2.69 343 140 135 141 76 76 81 68 [mm] Product numbers H3 9.50 12.16 241 309 D1 D2 D3 D4 D5 D6 D7 1.44 2.50 3.42 4.63 0.50 2.06 2.56 37 64 87 117 13 52 65 M M12 Connections Product number Model type UPS 32-160/2 (1 ph) H2 Flange size Voltage [V] Cast Iron Bronze 96402730 96402739 115 96402733 96402740 230 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed P Max [Watts] Start amps [A] 115V 230V 115V 230V 3 5.80 2.90 625 14.60 6.70 2 5.80 2.90 600 14.60 6.70 1 5.50 2.75 555 13.84 6.35 29 UPS 32-160/2 Curve charts and technical data UP, UPS Series 200 9 UPS 32-160/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [ft] 50 H [m] 14 12 10 8 6 4 2 0 3 40 1 2 Flow range: 9 - 76 gpm Head range: 1 - 45 ft Motor: 2-pole 0.75 Hp Max. liquid temp (Open): +140 °F 30 Max. liquid temp.: +248 °F 20 Min. liquid temp.: +32 °F 10 0 0 0 P1 [hp] P1 [W] 800 1.0 600 400 0.5 200 0.0 0 0 10 20 2 4 30 6 40 50 60 70 80 Q [US GPM] 10 12 14 16 18 Q [m³/h] 8 80 Eta [%] 60 2 40 Eta 20 0 70 80 Q [US GPM] 1 10 20 30 40 50 60 145 psi Net wt: 36.8 lbs (16.7 kg) Gross wt.: 44.8 lbs (20.3 kg) Shipping volume: 1.70 ft3 (0.048 m3) Net wt. bronze: 41.2 lbs (18.7 kg) Gross wt. bronze: 49.4 lbs (22.4 kg) Shipping volume bronze: 1.70 ft3 (0.048 m3) TM00 9495 0697 3 Max. system pressure: Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 B5 D6 D7 Dimensions Model UPS 32-160/2 [in] L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 13.50 5.50 5.31 5.56 3.00 3.00 3.19 2.69 9.50 12.16 1.44 2.50 3.42 4.63 0.50 2.06 2.56 343 140 135 141 76 76 81 68 241 309 37 64 87 117 13 52 65 [mm] Product numbers M12 Connections Product number Cast Iron Bronze Voltage [V] 96402736 96402741 208-230 96402737 96402742 460 96402738 96402743 575 ★ Model type UPS 32-160/2 (3 ph) M Flange size 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed 30 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 575V ★ 3 1.96 0.98 0.78 600 9.30 4.70 3.76 2 1.25 0.63 0.50 430 5.93 3.02 2.40 1 1.12 ▲ ▲ 380 5.31 ▲ ▲ UP, UPS Series 200 9 UPS 40-40/4 1 ph, 115 V, 230 V, 60 Hz H [ft] 12 H [m] 3 2 1 10 3 8 2 6 4 1 2 0 0 10 20 30 40 50 60 70 80 90 Q [US GPM] 0 P1 [hp] P1 [W] 300 0.4 0.3 200 0.2 100 0.1 0.0 0 0 2 4 6 8 10 12 14 16 18 20 Q [m³/h] 60 Eta [%] 2 1 40 3 20 Eta 0 10 20 30 40 50 60 70 80 90 Q [US GPM] 13 - 85 gpm Head range: 1 - 11 ft Motor: 4-pole 0.33 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 37.9 lbs (17.2 kg) Gross wt.: 46.1 lbs (20.9 kg) Shipping volume: 1.70 ft3 (0.048 m3) Net wt. bronze: 42.3 lbs (19.2 kg) Gross wt. bronze: 50.5 lbs (22.9 kg) Shipping volume bronze: 1.70 ft3 (0.048 m3) TM00 9513 0697 0 Flow range: Curve charts and technical data UPS 40-40/4, 1 ph, 115 V, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 D6 B5 D7 Dimensions Model UPS 40-40/4 [in] L1 L3 B1 B2 B4 B5 B7 H1 H2 13.50 6.75 5.31 5.56 3.00 3.00 4.75 2.69 9.69 343 171 135 141 76 76 121 68 246 [mm] Product numbers D1 315 41 D2 D3 D4 D5 D6 D7 2.88 3.42 5.00 0.50 2.06 2.56 73 87 127 13 52 65 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96402748 96402753 115 96402749 96402754 230 Model type UPS 40-40/4 (1 ph) H3 12.40 1.63 Flange size 1.50" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed Start amps [A] P Max [Watts] 115V 230V 115V 230V 3 1.60 0.80 170 3.10 1.50 2 1.48 0.74 150 2.87 1.39 1 1.34 0.66 125 2.60 1.24 31 UPS 40-40/4 Curve charts and technical data UP, UPS Series 200 9 UPS 40-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [ft] 12 H [m] 3 10 3 1 2 8 2 1 13 - 85 gpm Head range: 1 - 11 ft Motor: 4-pole 0.33 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F 6 Min. liquid temp.: +32 °F 4 Max. system pressure: 145 psi 2 Net wt: 37.7 lbs (17.1 kg) 0 0 10 20 30 40 50 60 70 80 90 Q [US GPM] 0 P1 [hp] P1 [W] 300 0.4 0.3 200 0.2 100 0.1 0.0 0 0 2 4 6 10 12 14 16 18 20 Q [m³/h] 8 60 Eta [%] 3 1 45.9 lbs (20.8 kg) Shipping volume: 1.70 ft3 (0.048 m3) Net wt. bronze: 42.1 lbs (19.1 kg) Gross wt. bronze: 50.3 lbs (22.8 kg) Shipping volume bronze: 1.70 ft3 (0.048 m3) 40 20 2 Gross wt.: TM00 9496 0697 0 Flow range: Eta 0 10 20 30 40 50 60 70 80 90 Q [US GPM] Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 B5 D6 D7 Dimensions Model [in] UPS 40-40/4 L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 13.50 6.75 5.31 5.56 3.00 3.00 4.75 2.69 9.69 12.40 1.63 2.88 3.42 5.00 0.50 2.06 2.56 343 171 135 141 76 76 121 68 246 315 41 73 87 127 13 52 65 [mm] Product numbers M12 Connections Product number Cast Iron Bronze Voltage [V] 96402750 96402755 208-230 96402751 96402756 460 96402752 96402757 575 ★ Model type UPS 40-40/4 (3 ph) M Flange size 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed 32 208-230V 460V 575V ★ 3 0.88 0.44 0.33 2 0.42 0.21 0.17 1 0.36 ▲ ▲ ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 260 2.50 1.30 1.04 120 1.19 0.62 0.50 100 1.02 ▲ ▲ UP, UPS Series 200 9 UPS 40-80/4 1 ph, 115 V, 230 V, 60 Hz H [ft] 25 H [m] 7 6 5 4 3 2 1 0 3 2 1 20 Flow range: 13 - 120 gpm Head range: 1 - 25 ft Motor: 4-pole 0.50 Hp Max. liquid temp (Open): +140 °F 15 Max. liquid temp.: +248 °F 10 Min. liquid temp.: +32 °F 5 0 20 0 P1 [hp] P1 [W] 600 0.8 0.6 400 0.4 200 0.2 0.0 0 0 5 40 60 10 80 15 100 20 120 25 2 140 Q [US GPM] Q [m³/h] 30 60 Eta [%] 3 40 1 20 Eta 20 40 60 80 100 0 140 Q [US GPM] 120 145 psi Net wt: 57.8 lbs (26.2 kg) Gross wt.: 70.1 lbs (31.8 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 62.2 lbs (28.2 kg) Gross wt. bronze: 74.5 lbs (33.8 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9514 2297 0 Max. system pressure: Curve charts and technical data UPS 40-80/4, 1 ph, 115 V, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 D5 M B4 NPT 1/4 TM02 0729 5100 L3 D4 L1 D1 D6 B5 D7 Dimensions Model UPS 40-80/4 L1 L3 13.50 6.75 [in] 343 [mm] B1 B2 B4 B5 B7 H1 5.75 6.68 3.94 3.94 4.75 3.00 146 170 100 100 121 76 171 Product numbers H3 D1 9.00 12.01 1.69 229 305 43 D2 D3 D4 D5 D6 D7 2.88 3.42 5.00 0.50 2.06 2.56 73 87 127 13 52 65 M M12 Connections Product number Model type UPS 40-80/4 (1 ph) H2 Flange size Voltage [V] Cast Iron Bronze 96404948 96404953 115 96404949 96404954 230 1.50" non ANSI 2 bolt w/ (2) 1/2" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed Start amps [A] P Max [Watts] 115V 230V 115V 230V 3 5.50 2.75 565 9.50 4.70 2 5.15 2.60 485 8.90 4.44 1 4.30 2.15 410 7.43 3.67 33 UPS 40-80/4 Curve charts and technical data UP, UPS Series 200 9 UPS 40-80/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [ft] 25 H [m] 7 6 5 4 3 2 1 0 3 2 20 1 15 10 5 0 20 0 P1 [hp] P1 [W] 600 0.8 0.6 400 0.4 200 0.2 0.0 0 0 5 40 60 10 80 15 100 20 120 30 3 2 1 20 40 60 80 100 4-pole 0.50 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 47.6 lbs (21.6 kg) 60.0 lbs (27.2 kg) 2.90 ft3 (0.082 m3) Net wt. bronze: 52.0 lbs (23.6 kg) 60 Eta [%] Gross wt. bronze: 64.4 lbs (29.2 kg) 40 Shipping volume bronze: 2.90 ft3 (0.082 m3) Q [m³/h] 0 140 Q [US GPM] 120 Motor: Shipping volume: 20 Eta 1 - 25 ft Gross wt.: 140 Q [US GPM] 25 13 - 120 gpm Head range: TM00 9498 0307 0 Flow range: Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 D5 M B4 NPT 1/4 B5 TM02 0729 5100 L3 D4 L1 D1 D6 D7 Dimensions Model L1 [in] UPS 40-80/4 [mm] L3 13.50 6.75 343 171 B1 B2 B4 B5 B7 H1 5.75 6.68 3.94 3.94 4.75 3.00 146 170 100 100 121 76 Product numbers H3 D1 229 305 43 D2 D3 D4 D5 D6 D7 2.88 3.42 5.00 0.50 2.06 2.56 73 87 127 13 52 65 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96402750 96402755 208-230 96402751 96402756 460 96402752 96402757 575 ★ Model type UPS 40-80/4 (3 ph) H2 9.00 12.01 1.69 Flange size 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed 34 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 575V ★ 3 1.98 0.99 0.78 550 7.10 4.70 3.76 2 1.20 0.60 0.48 370 4.30 4.44 3.55 1 1.00 ▲ ▲ 305 3.59 ▲ ▲ UP, UPS Series 200 9 UPS 40-80/2 1 ph, 115 V, 230 V, 60 Hz H [m] 8 Flow range: 13 - 105 gpm Head range: 1 - 30 ft Motor: 2-pole 0.75 Hp 20 Max. liquid temp (Open): +140 °F 15 Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F H [ft] 30 25 6 4 1 2 3 10 2 5 0 0 20 0 P1 [hp] P1 [W] 600 0.8 0.6 400 0.4 200 0.2 0.0 0 0 5 40 60 10 80 15 100 20 40 60 80 1.70 ft3 (0.048 m3) Net wt. bronze: 42.8 lbs (19.4 kg) 60 Eta [%] Gross wt. bronze: 50.9 lbs (23.1 kg) 40 Shipping volume bronze: 1.70 ft3 (0.048 m3) 20 Eta 20 46.5 lbs (21.1 kg) Shipping volume: Q [m³/h] 3 2 1 0 120 Q [US GPM] 100 38.4 lbs (17.4 kg) Gross wt.: 120 Q [US GPM] 25 145 psi Net wt: TM00 9515 0307 0 Max. system pressure: Curve charts and technical data UPS 40-80/2, 1 ph, 115 V, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 B5 D6 D7 Dimensions L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 13.50 6.75 5.31 5.56 3.00 3.00 3.13 2.69 9.63 12.36 1.69 2.88 3.42 5.00 0.50 2.06 2.56 343 171 135 141 76 76 79 68 244 314 43 73 87 127 13 52 65 Model UPS 40-80/2 [in] [mm] Product numbers M12 Connections Product number Model type UPS 40-80/2 (1 ph) M Flange size Voltage [V] Cast Iron Bronze 96402762 96402767 115 96402763 96402768 230 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed P Max [Watts] Start amps [A] 115V 230V 115V 230V 3 4.45 2.24 480 11.00 5.60 2 4.40 2.20 450 10.88 5.50 1 4.40 2.18 440 10.88 5.45 35 UPS 40-80/2 Curve charts and technical data UP, UPS Series 200 9 UPS 40-80/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [ft] 30 H [m] 8 25 20 6 3 2 1 15 4 10 2 5 0 0 20 40 0 P1 [hp] P1 [W] 600 0.8 0.6 400 0.4 200 0.2 0.0 0 0 5 60 10 80 15 100 20 120 Q [US GPM] Q [m³/h] 25 60 Eta [%] 40 3 2 1 20 Eta 20 40 60 80 0 120 Q [US GPM] 100 13 - 105 gpm Head range: 1 - 30 ft Motor: 2-pole 0.75 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 38.4 lbs (17.4 kg) Gross wt.: 46.5 lbs (21.1 kg) Shipping volume: 1.70 ft3 (0.048 m3) Net wt. bronze: 42.8 lbs (19.4 kg) Gross wt. bronze: 50.9 lbs (23.1 kg) Shipping volume bronze: 1.70 ft3 (0.048 m3) TM00 9497 0697 0 Flow range: Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 B5 D6 D7 Dimensions L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 13.50 6.75 5.31 5.56 3.00 3.00 3.13 2.69 9.63 12.36 1.69 2.88 3.42 5.00 0.50 2.06 2.56 343 171 135 141 76 76 79 68 244 314 43 73 87 127 13 52 65 Model [in] UPS 40-80/2 [mm] Product numbers M12 Connections Product number Flange size Voltage [V] Model type UPS 40-80/2 (3 ph) M Cast Iron Bronze 96402764 96402769 96402765 96402770 460 96402766 96402771 575 ★ 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 208-230 Electrical data Max amps [A] Speed 36 208-230V 460V 575V ★ 3 1.45 0.73 0.58 2 0.94 0.47 0.38 1 0.86 ▲ ▲ ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 440 7.40 3.70 2.96 320 4.80 2.38 1.90 290 4.39 ▲ ▲ UP, UPS Series 200 9 UPS 40-160/2 1 ph, 115 V, 230 V, 60 Hz H [ft] 50 H [m] 14 12 10 8 6 4 2 0 40 2 3 1 Flow range: 13 - 110 gpm Head range: 1 - 46 ft Motor: 2-pole 0.75 Hp Max. liquid temp (Open): +140 °F 30 Max. liquid temp.: +248 °F 20 Min. liquid temp.: +32 °F 10 0 20 0 P1 [hp] P1 [W] 1000 750 1.0 500 0.5 250 0.0 0 0 5 40 60 10 80 100 15 20 120 Q [US GPM] 1 Eta 40 60 80 80 Eta [%] 60 40 20 0 120 Q [US GPM] 3 2 20 Q [m³/h] 25 100 145 psi Net wt: 43.2 lbs (19.6 kg) Gross wt.: 55.6 lbs (25.2 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 47.6 lbs (21.6 kg) Gross wt. bronze: 60 lbs (27.2 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9516 0307 0 Max. system pressure: Curve charts and technical data UPS 40-160/2, 1 ph, 115 V, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 D5 M B4 NPT 1/4 B5 TM02 0729 5100 L3 D4 L1 D1 D6 D7 Dimensions Model UPS 40-160/2 [in] [mm] L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 11.50 5.75 5.75 6.68 3.94 3.94 3.19 2.31 9.00 11.69 1.69 2.88 3.42 5.00 0.50 2.06 2.56 292 146 146 170 100 100 81 59 229 297 43 73 87 127 13 52 65 Product numbers M12 Connections Product number Model type UPS 40-160/2 (1 ph) M Flange size Voltage [V] Cast Iron Bronze 96402782 96402787 115 96402783 96402788 230 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed P Max [Watts] Start amps [A] 115V 230V 115V 230V 3 8.40 4.20 890 18.60 9.30 2 7.45 3.75 760 16.50 8.30 1 6.95 3.45 690 15.39 7.64 37 UPS 40-160/2 Curve charts and technical data UP, UPS Series 200 9 UPS 40-160/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [m] 14 12 10 8 6 4 2 0 H [ft] 50 3 40 2 1 Flow range: 13 - 110 gpm Head range: 1 - 46 ft Motor: 2-pole 0.75 Hp Max. liquid temp (Open): +140 °F 30 Max. liquid temp.: +248 °F 20 Min. liquid temp.: +32 °F 10 0 0 20 40 0 P1 [hp] P1 [W] 1000 750 1.0 500 0.5 250 0.0 0 0 5 60 10 80 15 100 20 120 Q [US GPM] Q [m³/h] 25 80 Eta [%] 60 2 40 Eta 20 0 100 120 Q [US GPM] 1 20 40 60 80 145 psi Net wt: 43.2 lbs (19.6 kg) Gross wt.: 55.6 lbs (25.2 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 47.6 lbs (21.6 kg) Gross wt. bronze: 60 lbs (27.2 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9499 0307 3 Max. system pressure: Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 B5 D6 D7 Dimensions Model UPS 40-160/2 [in] [mm] L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 11.50 5.75 5.75 6.68 3.94 3.94 3.19 2.31 9.00 11.69 1.69 2.88 3.42 5.00 0.50 2.06 2.56 292 146 146 170 100 100 81 59 229 297 43 73 87 127 13 52 65 Product numbers M12 Connections Product number Flange size Voltage [V] Model type UPS 40-160/2 (3 ph) M Cast Iron Bronze 96402784 96402789 208-230 96402785 96402790 460 96402786 96402791 575 ★ 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed 38 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 575V ★ 3 2.50 1.25 1.00 800 12.40 6.20 4.96 2 1.75 0.88 0.70 570 8.68 4.36 3.50 1 1.55 ▲ ▲ 500 7.69 ▲ ▲ UP, UPS Series 200 9 UPS 40-240/2 1 ph, 230 V, 60 Hz H [m] H [ft] 60 50 15 1 3 2 40 10 30 20 5 10 0 0 20 0 P1 [hp] P1 [W] 2.0 1500 1.5 1000 1.0 500 0.5 0.0 0 0 5 40 60 10 80 15 100 20 120 25 30 40 20 Eta 20 40 60 80 100 Q [m³/h] 60 Eta [%] 3 2 1 140 Q [US GPM] 120 0 140 Q [US GPM] 13 - 130 gpm Head range: 1 - 62 ft Motor: 2-pole 1.5 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 54.0 lbs (24.5 kg) Gross wt.: 66.4 lbs (30.1 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 58.4 lbs (26.5 kg) Gross wt. bronze: 70.8 lbs 32.1 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9517 0307 0 Flow range: Curve charts and technical data UPS 40-240/2, 1 ph, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 D5 M B4 NPT 1/4 B5 TM02 0729 5100 L3 D4 L1 D1 D6 D7 Dimensions Model UPS 40-240/2 L1 L3 13.50 3.75 [in] [mm] 343 95 B1 B2 B4 B5 B7 H1 5.75 6.68 4.00 4.00 3.19 2.69 146 170 102 102 81 68 Product numbers H3 D1 11.06 13.96 1.69 281 355 43 D2 D3 D4 D5 D6 D7 2.88 3.42 5.00 0.50 2.06 2.56 73 87 127 13 52 65 M M12 Connections Product number Model type UPS 40-240/2 (1 ph) H2 Cast Iron Bronze 96402797 96402804 Voltage [V] Flange size 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 230 Electrical data Speed Max amps [A] P Max [Watts] 230V 3 Start amps [A] 230V 6.20 1350 11.80 2 5.55 1200 10.56 1 5.15 1100 9.80 39 UPS 40-240/2 Curve charts and technical data UP, UPS Series 200 9 UPS 40-240/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 20 15 10 5 0 H [ft] 70 60 50 40 30 20 10 0 0 3 1 2 20 0 P1 [hp] P1 [W] 2.0 1500 1.5 1000 1.0 500 0.5 0.0 0 0 40 5 60 10 80 15 100 20 120 25 140 Q [US GPM] 30 3 1 2 40 60 80 100 60 Eta [%] 40 Eta 20 Q [m³/h] 20 0 140 Q [US GPM] 120 Flow range: 13 - 130 gpm Head range: 1 - 62 ft Motor: 2-pole 1.5 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 47.2 lbs (21.4 kg) Gross wt.: 59.5 lbs (27.0 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 51.6 lbs (23.4 kg) Gross wt. bronze: 63.9 lbs (29.0 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9500 0307 H [m] Note: ETA is calculated as wire-to-water efficiency. H1 D2 B7 B 2 D3 H3 H2 B1 L3 TM02 0729 5100 D4 L1 D1 D5 M B4 NPT 1/4 B5 D6 D7 Dimensions Model L1 UPS 40-240/2 [in] [mm] L3 13.50 3.75 343 95 B1 B2 B4 B5 B7 H1 5.75 6.68 4.00 4.00 3.19 2.69 146 170 102 102 81 68 Product numbers H3 D1 281 355 43 D2 D3 D4 D5 D6 D7 2.88 3.42 5.00 0.50 2.06 2.56 73 87 127 13 52 65 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96402798 96402805 208-230 96402799 96402807 460 96402801 96402809 575 ★ Model type UPS 40-240/2 (3 ph) H2 11.06 13.96 1.69 Flange size 1.5" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 Electrical data Max amps [A] Speed 40 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 3 4.50 2.25 1.80 1440 23.80 11.60 575V ★ 9.28 2 3.25 1.63 1.30 1100 17.19 8.40 6.72 1 2.95 ▲ ▲ 990 15.6 ▲ ▲ UP, UPS Series 200 9 UPS 50-40/4 1 ph, 115 V, 230 V, 60 Hz 4 3 2 1 0 2 3 20 0 P1 [hp] P1 [W] 300 0.4 0.3 200 0.2 100 0.1 0.0 0 0 40 5 60 10 80 15 100 20 120 140 Q [US GPM] 25 Q [m³/h] 30 60 Eta [%] 3 2 40 1 20 Eta 20 40 60 80 100 120 0 140 Q [US GPM] Flow range: 20 - 125 gpm Head range: 1 - 12 ft Motor: 4-pole 0.33 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 43.7 lbs (19.8 kg) Gross wt.: 51.8 lbs (23.5 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 53.6 lbs (24.3 kg) Gross wt. bronze: 61.7 lbs (28.0 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9518 0307 H [ft] 14 12 10 1 8 6 4 2 0 0 H [m] Curve charts and technical data UPS 50-40/4, 1 ph, 115 V, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 L3 TM02 0730 5100 L1 D6 D7 D1 D5 M NPT 1/4 B4 D2 B5 Dimensions Model UPS 50-40/4 L1 L3 14.00 7.00 [in] 356 [mm] B1 B2 B4 B5 B7 5.31 5.56 3.56 3.00 4.75 135 141 90 76 121 178 H1 Product numbers H3 D1 3.25 10.13 13.08 2.13 83 257 332 54 D2 D3 D4 D5 D6 D7 3.44 4.05 5.25 0.55 2.50 3.06 87 103 133 14 64 78 M M12 Connections Product number Model type UPS 50-40/4 (1 ph) H2 Flange size Voltage [V] Cast Iron Bronze 96402814 96402819 115 96402815 96402820 230 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes Flange type GF 50 Electrical data Max amps [A] Speed Start amps [A] P Max [Watts] 115V 230V 115V 230V 3 2.66 1.32 285 5.20 2.60 2 2.60 1.30 244 5.08 2.56 1 2.20 1.10 204 4.30 2.17 41 UPS 50-40/4 Curve charts and technical data UP, UPS Series 200 9 UPS 50-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 4 3 2 1 0 0 P1 [hp] P1 [W] 300 0.4 0.3 200 0.2 100 0.1 0.0 0 0 40 5 60 10 80 15 100 20 120 25 140 Q [US GPM] 30 60 Eta [%] 3 40 2 1 20 Eta 20 40 60 80 Q [m³/h] 100 120 0 140 Q [US GPM] Flow range: 20 - 125 gpm Head range: 1 - 12 ft Motor: 4-pole 0.33 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 43.7 lbs (19.8 kg) Gross wt.: 51.8 lbs (23.5 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 53.6 lbs (24.3 kg) Gross wt. bronze: 61.7 lbs (28.0 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9501 0307 H [ft] 14 3 12 10 1 2 8 6 4 2 0 0 20 H [m] Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 L3 TM02 0730 5100 L1 D6 D7 D1 D5 M NPT 1/4 B4 D2 B5 Dimensions Model L1 [in] UPS 50-40/4 [mm] L3 14.00 7.00 356 178 B1 B2 B4 B5 B7 5.31 5.56 3.56 3.00 4.75 135 141 90 76 121 H1 H3 D1 3.25 10.13 13.08 2.13 83 Product numbers 257 332 54 D2 D3 D4 D5 D6 D7 3.44 4.05 5.25 0.55 2.50 3.06 87 103 133 14 64 78 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96402816 96402821 208-230 96402817 96402822 460 96402818 96402823 575 ★ Model type UPS 50-40/4 (3 ph) H2 Flange size 1" non ANSI 4 bolt w/ (4) 0.56" dia. holes Flange type GF 50 Electrical data Max amps [A] Speed 42 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 575V ★ 3 1.40 0.70 0.56 270 4.60 2.30 1.84 2 0.66 0.33 0.26 170 2.17 1.08 0.86 1 0.54 ▲ ▲ 150 1.77 ▲ ▲ UP, UPS Series 200 9 UPS 50-80/4 1 ph, 115 V, 230 V, 60 Hz H [ft] 25 H [m] 7 6 5 4 3 2 1 0 3 20 2 1 15 10 5 0 0 P1 [hp] P1 [W] 1000 800 1.0 600 400 0.5 200 0.0 0 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 5 10 15 20 25 30 35 40 Q [m³/h] 50 Eta [%] 40 3 2 30 1 20 Eta 10 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 20 - 160 gpm Head range: 1 - 24 ft Motor: 4-pole 0.75 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 60.2 lbs (27.3 kg) Gross wt.: 72.5 lbs (32.9 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 66.8 lbs (30.3 kg) Gross wt. bronze: 79.1 lbs (35.9 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9519 0307 0 Flow range: Curve charts and technical data UPS 50-80/4, 1 ph, 115 V, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 D5 M TM02 0730 5100 L3 L1 D6 D7 D1 NPT 1/4 B4 D2 B5 Dimensions Model UPS 50-80/4 [in] L1 L3 B1 B2 B4 B5 B7 H1 11.50 7.00 5.75 6.68 4.38 3.94 4.75 3.25 292 178 146 170 111 100 121 83 [mm] Product numbers H3 10.88 14.23 276 361 D1 D2 D3 D4 D5 D6 D7 2.13 3.44 3.44 5.25 0.55 2.50 3.06 54 87 87 133 14 64 78 M M12 Connections Product number Model type UPS 50-80/4 (1 ph) H2 Flange size Voltage [V] Cast Iron Bronze 96404958 96404963 115 96404959 96404964 230 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes Flange type GF 50 Electrical data Max amps [A] Speed Start amps [A] P Max [Watts] 115V 230V 3 7.55 3.80 115V 230V 720 13.20 6.50 2 6.85 1 5.15 3.40 620 11.98 5.82 2.60 480 9.00 4.45 43 UPS 50-80/4 Curve charts and technical data UP, UPS Series 200 9 UPS 50-80/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [ft] 25 H [m] 7 6 5 4 3 2 1 0 20 3 2 1 Flow range: 20 - 160 gpm Head range: 1 - 24 ft Motor: 4-pole 0.75 Hp Max. liquid temp (Open): +140 °F 15 Max. liquid temp.: +248 °F 10 Min. liquid temp.: +32 °F 5 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 0 P1 [hp] P1 [W] 1000 800 1.0 600 400 0.5 200 0.0 0 0 5 10 15 20 25 30 35 40 Q [m³/h] 50 Eta [%] 40 3 30 2 20 1 10 Eta 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 145 psi Net wt: 59.5 lbs (27.0 kg) Gross wt.: 71.9 lbs (32.6 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 66.8 lbs (30.3 kg) Gross wt. bronze: 79.1 lbs (35.9 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9502 0307 0 Max. system pressure: Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 TM02 0730 5100 L3 L1 D6 D7 D1 D5 M NPT 1/4 B4 D2 B5 Dimensions Model [in] UPS 50-80/4 L1 L3 B1 B2 B4 B5 B7 H1 11.50 7.00 5.75 6.68 4.38 3.94 4.75 3.25 292 178 146 170 111 100 121 83 [mm] H2 10.88 14.23 Product numbers 276 361 D1 D2 D3 D4 D5 D6 D7 2.13 3.44 3.44 5.25 0.55 2.50 3.06 54 87 87 133 14 64 78 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96404960 96404965 208-230 96404961 96404966 460 96404962 96404967 575 ★ Model type UPS 50-80/4 (3 ph) H3 Flange size 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes Flange type GF 50 Electrical data Max amps [A] Speed 44 208-230V 460V 575V ★ 3 2.44 1.22 0.98 2 1.44 0.72 0.58 1 1.24 ▲ ▲ ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 640 8.50 4.30 3.44 450 5.02 2.54 2.00 390 4.32 ▲ ▲ UP, UPS Series 200 9 UPS 50-80/2 1 ph, 115 V, 230 V, 60 Hz H [ft] 35 30 25 20 15 10 5 0 0 10 8 6 4 2 0 3 2 1 20 0 P1 [hp] P1 [W] 800 1.0 600 400 0.5 200 0.0 0 0 5 20 40 60 10 80 100 120 140 160 Q [US GPM] 15 40 60 20 25 30 Q [m³/h] 35 80 Eta [%] 60 3 2 40 1 20 Eta 0 80 100 120 140 160 Q [US GPM] Flow range: 20 - 150 gpm Head range: 1 - 30 ft Motor: 2-pole 0.75 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 46.7 lbs (21.2 kg) Gross wt.: 54.2 lbs (24.6 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 52.2 lbs (27.3 kg) Gross wt. bronze: 59.7 lbs (27.1 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9520 0697 H [m] Curve charts and technical data UPS 50-80/2, 1 ph, 115 V, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 L3 TM02 0730 5100 L1 D6 D7 D1 D5 M NPT 1/4 B4 D2 B5 Dimensions Model UPS 50-80/2 L1 L3 B1 B2 B4 B5 B7 H1 [in] 11.5 7.00 5.31 5.56 3.75 3.00 4.75 3.00 [mm] 292 178 135 141 95 76 121 76 Product numbers H3 D1 9.88 12.86 2.13 251 327 54 D2 D3 D4 D5 D6 D7 3.44 4.06 5.25 0.55 2.50 3.06 87 103 133 14 64 78 M M12 Connections Product number Model type UPS 50-80/2 (1 ph) H2 Flange size Voltage [V] Cast Iron Bronze 96402834 96402843 115 96402836 96402844 230 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes Flange type GF 50 Electrical data Max amps [A] Speed P Max [Watts] Start amps [A] 115V 230V 115V 230V 3 5.85 2.95 630 14.60 7.30 2 5.80 2.90 610 14.48 7.18 1 5.70 2.85 600 14.23 7.05 45 UPS 50-80/2 Curve charts and technical data UP, UPS Series 200 9 UPS 50-80/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 10 8 6 4 2 0 3 2 1 0 P1 [hp] P1 [W] 800 1.0 600 400 0.5 200 0.0 0 0 20 40 5 10 20 40 60 80 100 120 140 160 Q [US GPM] 15 20 25 30 35 Q [m³/h] 80 Eta [%] 3 60 40 2 1 Eta 20 0 80 100 120 140 160 Q [US GPM] 60 Flow range: 20 - 150 gpm Head range: 1 - 30 ft Motor: 2-pole 0.75 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 49.5 lbs (20.8 kg) Gross wt.: 53.4 lbs (24.2 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 52.2 lbs (23.7 kg) Gross wt. bronze: 59.7 lbs (27.1 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9503 0307 H [ft] 35 30 25 20 15 10 5 0 0 H [m] Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 L3 TM02 0730 5100 L1 D6 D7 D1 D5 M NPT 1/4 B4 D2 B5 Dimensions Model UPS 50-80/2 L1 L3 B1 B2 B4 B5 B7 H1 [in] 11.5 7.00 5.31 5.56 3.75 3.00 4.75 3.00 [mm] 292 178 135 141 95 76 121 76 Product numbers H3 D1 9.88 12.86 2.13 251 327 54 D2 D3 D4 D5 D6 D7 3.44 4.06 5.25 0.55 2.50 3.06 87 103 133 14 64 78 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96402838 96402845 208-230 96402840 96402846 460 96402842 96402847 575 ★ Model type UPS 50-80/2 (3 ph) H2 Flange size 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes Flange type GF 50 Electrical data Max amps [A] Speed 46 208-230V 460V 575V ★ 3 1.92 0.96 0.77 2 1.20 0.60 0.48 1 1.08 ▲ ▲ ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 610 9.30 4.70 3.76 440 5.81 2.94 2.40 400 5.23 ▲ ▲ UP, UPS Series 200 9 UPS 50-160/2 1 ph, 230 V, 60 Hz H [ft] 50 H [m] 14 12 10 8 6 4 2 0 3 2 1 40 Flow range: 20 - 170 gpm Head range: 1 - 46 ft Motor: 2-pole 1.50 Hp Max. liquid temp (Open): +140 °F 30 Max. liquid temp.: +248 °F 20 Min. liquid temp.: +32 °F 10 0 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 0 P1 [hp] P1 [W] 2.0 1500 1.5 1000 1.0 500 0.5 0.0 0 0 5 10 15 20 25 30 35 40 Q [m³/h] 60 Eta [%] 3 145 psi Net wt: 53.6 lbs (24.3 kg) Gross wt.: 65.9 lbs (29.9 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 68.3 lbs (31.0 kg) Gross wt. bronze: 80.7 lbs (36.6 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) 40 20 Eta 0 20 40 60 80 100 120 140 160 180 Q [US GPM] TM00 9413 0307 2 1 Max. system pressure: Curve charts and technical data UPS 50-160/2, 1 ph, 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 D5 M TM02 0730 5100 L3 L1 D6 D7 D1 NPT 1/4 B4 D2 B5 Dimensions Model UPS 50-160/2 L1 L3 14.00 7.00 [in] [mm] 356 178 B1 B2 B4 B5 B7 5.75 6.68 3.94 3.94 4.75 146 170 100 100 121 Product numbers H2 H3 D1 3.00 10.81 13.78 2.13 76 275 350 54 D2 D3 D4 D5 D6 D7 3.44 4.05 5.25 0.55 2.50 3.06 87 103 133 14 64 78 M M12 Connections Product number Model type UPS 50-160/2 (1 ph) H1 Cast Iron Bronze 96411613 96411614 Voltage [V] Flange size 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes Flange type GF 50 230 Electrical data Speed Max amps [A] P Max [Watts] 230V 3 5.80 2 1 Start amps [A] 230V 1250 26.50 5.20 1100 23.76 4.85 1050 22.16 47 UPS 50-160/2 Curve charts and technical data UP, UPS Series 200 9 UPS 50-160/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575, 60 Hz H [m] 14 12 10 8 6 4 2 0 H [ft] 50 40 3 2 1 Flow range: 20 - 170 gpm Head range: 1 - 46ft Motor: 2-pole 1.50 Hp Max. liquid temp (Open): +140 °F 30 Max. liquid temp.: +248 °F 20 Min. liquid temp.: +32 °F 10 0 0 P1 [hp] P1 [W] 2.0 1500 1.5 1000 1.0 500 0.5 0.0 0 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 5 10 15 20 25 30 35 40 Q [m³/h] 60 Eta [%] 3 40 2 1 Eta 20 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 145 psi Net wt: 53.6 lbs (24.3 kg) Gross wt.: 65.9 lbs (29.9 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 68.3 lbs (31 kg) Gross wt. bronze: 80.7 lbs (36.6 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9504 0307 0 Max. system pressure: Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 D5 M TM02 0730 5100 L3 L1 D6 D7 D1 NPT 1/4 B4 D2 B5 Dimensions Model L1 [in] UPS 50-160/2 [mm] L3 14.00 7.00 356 178 B1 B2 B4 B5 B7 5.75 6.68 3.94 3.94 4.75 146 170 100 100 121 H1 76 Product numbers H3 D1 275 350 54 D2 D3 D4 D5 D6 D7 3.44 4.05 5.25 0.55 2.50 3.06 87 103 133 14 64 78 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96402860 96402866 208-230 96402861 96402868 460 96402862 96402870 575 ★ Model type UPS 50-160/2 (3 ph) H2 3.00 10.81 13.78 2.13 Flange size 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes Flange type GF 50 Electrical data Max amps [A] Speed 48 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 3 4.00 2.00 1.60 1300 22.80 11.40 575V ★ 9.12 2 3.00 1.50 1.20 1000 17.10 8.55 6.84 1 2.75 ▲ ▲ 950 15.68 ▲ ▲ UP, UPS Series 200 9 UPS 50-240/2 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [ft] 70 3 60 2 50 1 40 30 20 10 0 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 20 15 10 5 0 0 P1 [hp] P1 [W] 2000 2 1500 1000 1 500 0 0 0 5 10 15 20 25 30 35 40 Q [m³/h] 80 Eta [%] 60 3 2 40 1 Eta 20 0 20 40 60 80 100 120 140 160 180 Q [US GPM] Flow range: 20 - 180 gpm Head range: 1 - 62 ft Motor: 2-pole 2.00 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 60.6 lbs (27.5 kg) Gross wt.: 73.0 lbs (33.1 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 67.2 lbs (30.5 kg) Gross wt. bronze: 79.6 lbs (36.1 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9505 0307 H [m] Curve charts and technical data UPS 50-240/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 L3 TM02 0730 5100 L1 D6 D7 D1 D5 M NPT 1/4 B4 B5 H2 H3 D2 Dimensions Model L1 UPS 50-240/2 [in] [mm] L3 14.00 7.00 356 178 B1 B2 B4 B5 B7 H1 5.75 6.68 3.75 2.94 4.75 2.94 146 170 95 75 121 75 Product numbers D3 D4 D5 D6 D7 4.19 5.00 6.00 0.55 3.50 4.00 251 106 127 152 14 89 102 350 D1 52 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96402882 96402885 208-230 96402883 96402886 460 96402884 96402887 575 ★ Model type UPS 50-240/2 (3 ph) D2 9.88 13.78 2.06 Flange size 2" non ANSI 4 bolt w/ (4) 0.56" dia. holes Flange type GF 50 Electrical data Max amps [A] Speed ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 575V ★ 3 5.80 2.65 2.12 1700 26.50 15.40 12.32 2 3.95 1.98 1.68 1300 23.10 11.51 9.21 1 3.50 ▲ ▲ 1150 20.47 ▲ ▲ 49 UPS 53-55/57 Curve charts and technical data UP, UPS Series 200 9 UPS 53-55/57, 1 ph, 115 V, 230 V, 60 Hz 1 ph, 115 V, 230 V, 60 Hz 10 8 6 4 2 0 H [ft] 35 30 25 20 15 10 5 0 0 3 2 1 20 0 P1 [hp] P1 [W] 800 1.0 600 400 0.5 200 0.0 0 0 5 20 40 60 10 40 80 100 120 140 160 Q [US GPM] 15 20 25 30 35 Q [m³/h] 80 Eta [%] 60 3 2 40 1 20 Eta 0 80 100 120 140 160 Q [US GPM] 60 Flow range: 20 - 150 gpm Head range: 1 - 30 ft Motor: 4-pole 0.75 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 46.7 lbs (21.2 kg) Gross wt.: 54.2 lbs (24.6 kg) Shipping volume: 2.10 ft3 (0.06 m3) Net wt. bronze: 52.2 lbs (23.7 kg) Gross wt. bronze: 59.7 lbs (27.1 kg) Shipping volume bronze: 2.10 ft3 (0.06 m3) TM00 9520 0307 H [m] Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 TM02 0730 5100 L3 L1 D6 D7 D1 D5 M NPT 1/4 B4 D2 B5 Dimensions Model UPS 53-55/57 [in] [mm] L1 L3 B1 B2 B4 B5 B7 H1 11.88 5.94 5.31 5.56 3.75 2.94 4.75 2.94 302 151 135 141 95 75 121 75 Product numbers Product number D2 D3 D4 D5 D6 D7 9.88 12.86 2.06 4.19 5.00 6.00 0.63 3.50 4.00 251 106 127 152 16 89 102 50 327 D1 52 Flange size Voltage [V] Cast Iron Bronze M M12 96654373 96654392 115 96654374 96654393 230 Max amps [A] P Max [Watts] Flange type 2.0",2.5",3.0" non ANSI 4 bolt w/ (4) 0.63" dia. holes GF 53 Electrical data Speed H3 Connections Model type UPS 53-55/57 (1 ph) H2 Start amps [A] 115V 230V 115V 230V 3 5.85 2.95 630 14.60 7.30 2 5.80 2.85 613 14.48 7.18 1 5.70 2.80 600 14.23 7.05 UP, UPS Series 200 9 UPS 53-55/57 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 10 8 6 4 2 0 3 2 1 0 P1 [hp] P1 [W] 800 1.0 600 400 0.5 200 0.0 0 0 20 40 5 10 20 40 60 80 100 120 140 160 Q [US GPM] 15 20 25 30 35 Q [m³/h] 80 Eta [%] 3 60 40 2 1 Eta 20 0 80 100 120 140 160 Q [US GPM] 60 Flow range: 20 - 150 gpm Head range: 1 - 30 ft Motor: 2-pole 0.75 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 46.7 lbs (21.2 kg) Gross wt.: 54.2 lbs (24.6 kg) Shipping volume: 2.10 ft3 (0.06 m3) Net wt. bronze: 52.2 lbs (23.7 kg) Gross wt. bronze: 59.7 lbs (27.1 kg) Shipping volume bronze: 2.10 ft3 (0.06 m3) TM00 9503 0307 H [ft] 35 30 25 20 15 10 5 0 0 H [m] Curve charts and technical data UPS 53-55/57, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 L3 TM02 0730 5100 L1 D6 D7 D1 D5 M NPT 1/4 B4 B5 H2 H3 D2 Dimensions Model [in] UPS 53-55/57 [mm] L1 L3 B1 B2 B4 B5 B7 H1 11.88 5.94 5.31 5.56 3.75 2.94 4.75 2.94 302 151 135 141 95 75 121 75 Product numbers D3 D4 D5 D6 D7 4.19 5.00 6.00 0.63 3.50 4.00 251 106 127 152 16 89 102 327 D1 52 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96654375 96654394 208-230 96654376 96654395 460 96654377 96654396 575 ★ Model type UPS 53-55/57 (3 ph) D2 9.88 12.86 2.06 Flange size 2.0",2.5",3.0" non ANSI 4 bolt w/ (4) 0.63" dia. holes Flange type GF 53 Electrical data Max amps [A] Speed ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 575V ★ 3 1.92 0.96 0.77 610 9.30 4.70 3.76 2 1.20 0.60 0.48 440 5.81 2.94 2.40 1 1.08 ▲ ▲ 400 5.23 ▲ ▲ 51 UPS 75-69/2 Curve charts and technical data UP, UPS Series 200 9 UPS 75-69/2, 1 ph, 230 V, 60 Hz 1 ph, 230 V, 60 Hz H [ft] 50 H [m] 14 12 10 8 6 4 2 0 3 2 1 40 Flow range: 20 - 170 gpm Head range: 1 - 46 ft Motor: 2-pole 1.25 Hp Max. liquid temp (Open): +140 °F 30 Max. liquid temp.: +248 °F 20 Min. liquid temp.: +32 °F 10 0 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 0 P1 [hp] P1 [W] 2.0 1500 1.5 1000 1.0 500 0.5 0.0 0 0 5 10 15 20 25 30 35 40 Q [m³/h] 60 Eta [%] 145 psi Net wt: 53.6 lbs (24.3 kg) Gross wt.: 65.7 lbs (29.8 kg) Shipping volume: 3.50 ft3 (0.098 m3) Net wt. bronze: 68.3 lbs (31.0 kg) Gross wt. bronze: 80.5 lbs (36.5 kg) Shipping volume bronze: 3.50 ft3 (0.098 m3) 40 20 Eta 0 20 40 60 80 100 120 140 160 180 Q [US GPM] TM00 9413 0307 3 2 1 Max. system pressure: Note: ETA is calculated as wire-to-water efficiency. B1 D4 H3 H2 D3 B7 B 2 H1 L3 TM02 0730 5100 L1 D6 D7 D1 D5 M NPT 1/4 B4 B5 H2 H3 D2 Dimensions Model UPS 75-69/2 [in] L1 L3 B1 B2 B4 B5 B7 H1 14.25 7.13 5.69 6.68 3.94 3.94 4.50 2.94 362 181 145 170 100 100 114 75 [mm] Product numbers Product number Cast Iron Bronze 96654378 96654397 Voltage [V] 230 Electrical data Speed Max amps [A] P Max [Watts] 230V 52 3 5.80 2 1 275 350 D1 D2 D3 D4 D5 D6 D7 2.94 4.31 6.00 7.50 0.75 6.50 4.00 75 109 152 191 19 165 102 M M12 Connections Model type UPS 75-69/2 (1 ph) 10.81 13.78 Start amps [A] 230V 1250 26.50 5.20 1100 23.76 4.85 1050 22.16 Flange size 3" ANSI 125# R.F. Flange type GF80 UP, UPS Series 200 9 UPS 75-69/2 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [ft] 50 H [m] 14 12 10 8 6 4 2 0 40 3 2 1 Flow range: 20 - 170 gpm Head range: 1 - 46 ft Motor: 2-pole 1.25 Hp Max. liquid temp (Open): +140 °F 30 Max. liquid temp.: +248 °F 20 Min. liquid temp.: +32 °F 10 Max. system pressure: 145 psi Net wt: 53.6 lbs (24.3 kg) 0 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 0 P1 [hp] P1 [W] 2.0 1500 1.5 1000 1.0 500 0.5 0.0 0 0 5 10 15 20 25 30 35 40 Q [m³/h] 60 Eta [%] 3 Eta 20 0 20 40 60 80 100 120 140 160 180 Q [US GPM] 65.7 lbs (29.8 kg) Shipping volume: 3.50 ft3 (0.098 m3) Net wt. bronze: 68.3 lbs (31.0 kg) Gross wt. bronze: 80.5 lbs (36.5 kg) Shipping volume bronze: 3.50 ft3 (0.098 m3) TM00 9504 0307 40 2 1 Gross wt.: Curve charts and technical data UPS 75-69/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 TM02 0730 5100 L3 L1 D6 D7 D1 D5 M NPT 1/4 B4 D2 B5 Dimensions Model [in] UPS 75-69/2 L1 L3 B1 B2 B4 B5 B7 H1 14.25 7.13 5.69 6.68 3.94 3.94 4.50 2.94 362 181 145 170 100 100 114 75 [mm] Product numbers H3 275 350 D1 D2 D3 D4 D5 D6 D7 2.94 4.31 6.00 7.50 0.75 6.50 4.00 75 109 152 191 19 165 102 M M12 Connections Product number Cast Iron Bronze Voltage [V] 96654379 96654398 208-230 96654390 96654399 460 96654391 96654400 575 ★ Model type UPS 75-69/2 (3 ph) H2 10.81 13.78 Flange size 3" ANSI 125# R.F. Flange type GF80 Electrical data Max amps [A] Speed ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 3 4.00 2.00 1.60 1300 22.80 11.40 575V ★ 9.12 2 3.00 1.50 1.20 1000 17.10 8.55 6.84 1 2.75 ▲ ▲ 950 15.68 ▲ ▲ 53 UPS 80-40/4 Curve charts and technical data UP, UPS Series 200 9 UPS 80-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 4 3 2 1 0 3 2 1 40 0 P1 [hp] P1 [W] 600 0.8 0.6 400 0.4 200 0.2 0.0 0 0 80 10 120 20 160 30 200 Q [US GPM] Q [m³/h] 40 60 Eta [%] 1 40 80 120 2 3 40 Eta 20 0 200 Q [US GPM] 160 Flow range: 30 - 200 gpm Head range: 1 - 13 ft Motor: 4-pole 0.5 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 78.7 lbs (35.7 kg) Gross wt.: 9.1 lbs (41.3 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 91.9 lbs (41.7 kg) Gross wt. bronze: 104.3 lbs (47.3 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9506 0307 H [ft] 16 14 12 10 8 6 4 2 0 0 H [m] Note: ETA is calculated as wire-to-water efficiency. H1 D3 B7 B 2 D4 H3 H2 B1 L3 TM02 0730 5100 L1 D6 D7 D1 D5 M NPT 1/4 B4 B5 H2 H3 D2 Dimensions L1 Model [in] UPS 80-80/4 [mm] L3 19.00 9.50 483 241 B1 B2 B4 B5 B7 H1 5.75 6.68 4.94 3.94 6.31 3.81 146 170 125 100 160 97 Product numbers 11.25 15.15 3.19 286 385 81 D2 D3 D4 D5 D6 D7 5.00 6.00 7.56 0.75 — — 127 152 192 19 — — M M16 Connections Product number Cast Iron Bronze Voltage [V] 96402894 96402899 208-230 96402895 96402900 460 96402896 96402901 575 ★ Model type UPS 80-40/4 (3 ph) D1 Flange size 3" ANSI 125# R.F. Flange type GF80 Electrical data Max amps [A] Speed 54 208-230V 460V 575V ★ 3 1.62 0.81 0.65 2 0.87 0.44 0.35 1 0.77 ▲ ▲ ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 380 7.10 3.50 2.80 260 3.81 1.90 1.52 230 3.37 ▲ ▲ UP, UPS Series 200 9 UPS 80-80/4 3 ph, 208-230 V, 60 Hz H [ft] 30 25 3 20 2 1 15 10 5 0 0 50 0 P1 [hp] P1 [W] 1.5 1200 800 1.0 400 0.5 0.0 10 100 20 150 30 200 40 250 50 300 Q [US GPM] Q [m³/h] 60 60 Eta [%] 3 1 40 2 Eta 0 0 50 100 150 200 250 20 0 300 Q [US GPM] Flow range: 30 - 260 gpm Head range: 1 - 25 ft Motor: 4-pole 1.50 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 89.7 lbs (40.7 kg) Gross wt.: 102.1 lbs (46.3 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 102.3 lbs (46.4 kg) Gross wt. bronze: 114.6 lbs (52.0 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9507 0307 H [m] 9 8 7 6 5 4 3 2 1 0 Curve charts and technical data UPS 80-80/4, 3 ph, 208-230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H3 H2 B1 D4 D3 D2 D1 B7 NPT 1/4 B4 B5 H3 D1 TM02 0731 5100 M D5 L3 L1 B 2 H1 Dimensions Model UPS 80-80/4 L1 L3 19.00 9.50 [in] [mm] 483 241 B1 B2 B4 B5 B7 H1 5.75 6.68 4.94 3.94 6.31 3.81 146 170 125 100 160 97 Product numbers 286 385 81 D2 D3 D4 D5 D6 D7 5.00 6.00 7.56 0.75 — — 127 152 192 19 — — M M16 Connections Product number Model type UPS 80-80/4 (3 ph) H2 11.25 15.15 3.19 Cast Iron Bronze 96402908 96402913 Voltage [V] Flange size 3" ANSI 125# R.F. Flange type GF80 208-230 Electrical data Speed Max amps [A] P Max [Watts] 230V Start amps [A] 230V 3 3.60 1050 11.80 2 2.08 660 6.82 1 1.72 550 5.64 55 UP 80-160/2 Curve charts and technical data UP, UPS Series 200 9 UPS 80-160/2, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 3 ph, 208-230 V, 460 V, 575 V, 60 Hz H [ft] 50 H [m] 14 12 10 8 6 4 2 0 3 40 1 2 30 - 275 gpm Head range: 1 - 49 ft Motor: 2-pole 3.00 Hp Max. liquid temp (Open): +140 °F 30 Max. liquid temp.: +248 °F 20 Min. liquid temp.: +32 °F 10 Max. system pressure: 145 psi Net wt: 85.1 lbs (38.6 kg) 0 50 0 P1 [W] 3000 10 100 20 150 30 200 40 250 50 300 Q [US GPM] Q [m³/h] 60 60 Eta [%] 2000 2 1 1000 40 3 20 Eta 0 0 50 100 150 200 0 300 Q [US GPM] 250 Gross wt.: 97.4 lbs (44.2 kg) Shipping volume: 2.90 ft3 (0.082 m3) Net wt. bronze: 97.2 lbs (44.1 kg) Gross wt. bronze: 109.6 lbs (49.7 kg) Shipping volume bronze: 2.90 ft3 (0.082 m3) TM00 9508 00307 0 P1 [hp] 4 3 2 1 0 Flow range: Note: ETA is calculated as wire-to-water efficiency. H3 H2 B1 D4 D3 D2 D1 B7 NPT 1/4 B4 TM02 0731 5100 M D5 L3 L1 B 2 H1 B5 Dimensions Model L1 [in] UPS 80-160/2 [mm] L3 19.00 9.50 483 241 B1 B2 B4 B5 B7 H1 5.75 6.68 3.94 3.94 6.31 146 170 100 100 160 H3 D1 3.81 11.31 15.20 3.19 97 Product numbers 287 386 81 D2 D3 D4 D5 D6 D7 5.00 6.00 7.56 0.75 — — 127 152 192 19 — — M M16 Connections Product number Cast Iron Bronze Voltage [V] 96402920 96402923 208-230 96402921 96402924 460 96402922 96402925 575 ★ Model type UPS 80-160/2 (3 ph) H2 Flange size 3" ANSI 125# R.F. Flange type GF80 Electrical data Max amps [A] Speed 56 ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 208-230V 460V 575V ★ 3 6.35 3.13 2.54 2050 31.00 15.40 12.32 2 4.20 2.10 1.68 1550 20.50 10.17 8.14 1 4.05 ▲ ▲ 1500 19.77 ▲ ▲ UP, UPS Series 200 9 UP 100-40/4 3 ph, 208-230 V, 460 V, 575 V, 60 Hz 4 3 2 1 0 3 2 1 50 0 P1 [hp] P1 [W] 600 0.8 0.6 400 0.4 200 0.2 0.0 0 0 100 10 20 150 30 200 40 250 50 300 Q [US GPM] Q [m³/h] 60 60 Eta [%] 3 2 1 40 Eta 50 100 150 200 20 0 300 Q [US GPM] 250 Flow range: 30 - 270 gpm Head range: 1 - 12 ft Motor: 4-pole, 1.00 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +248 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 126.8 lbs (57.5 kg) Gross wt.: 138.9 lbs (63.0 kg) Shipping volume: 3.53 ft3 (0.1 m3) Net wt. bronze: 153.2 lbs (69.5 kg) Gross wt. bronze: 165.3 lbs (75.0 kg) Shipping volume bronze: 3.53 ft3 (0.1 m3) TM00 9509 0307 H [ft] 14 12 10 8 6 4 2 0 0 H [m] Curve charts and technical data UPS 100-40/4, 3 ph, 208-230 V, 460 V, 575 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. D4 D3 D1 B7 M NPT 1/4 B4 D5 L3 D2 L1 B 2 H1 TM02 0732 5100 H3 H2 B1 B5 Dimensions Model L1 [in] UPS 100-40/4 [mm] L3 B1 21.00 10.50 5.75 533 267 146 B2 B4 B5 B7 6.68 5.13 3.94 6.31 170 130 100 160 H1 D2 D3 D4 D5 D6 D7 4.81 12.31 16.61 4.19 6.19 7.50 9.06 0.75 — — 122 157 191 230 19 — — roduct numbers 313 H3 422 D1 106 M M16 Connections Product number Cast Iron Bronze Voltage [V] 96402934 96402937 208-230 96402935 96402938 460 96402936 96401961 575 ★ Model type UPS 100-40/4 (3 ph) H2 Flange size 4" ANSI 125# R.F. Flange type GF100 Electrical data Max amps [A] Speed 208-230V 460V 575V ★ 3 2.50 1.24 1.00 2 1.38 0.70 0.55 1 1.24 ▲ ▲ ▲ All 3-phase, 460V and 575V pumps are 2-speed only. ★ Canada only. Start amps [A] P Max [Watts] 208-230V 460V 575V ★ 570 10.80 5.40 4.32 435 5.96 3.05 2.44 390 5.36 ▲ ▲ 57 UP 43-70 Curve charts and technical data UP, UPS Series 200 9 UP 43-70, 1 ph, 115 V / 230 V, 60 Hz 1 ph, 115 V / 230 V, 60 Hz 8 6 4 2 0 P1 [hp] 0.6 0.4 0.2 0.0 H [ft] 28 24 20 16 12 8 4 0 0 10 20 30 40 50 60 70 80 90 100 Q [US GPM] 0 P1 [W] 500 400 300 200 100 0 0 5 10 15 20 Flow range: 15 - 100 gpm Head range: 1 - 23 ft Motor: 2-pole 0.50 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +230 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 33.1 lbs (15.0 kg) Gross wt.: 41.2 lbs (18.7 kg) Shipping volume: 1.70 ft3 (0.048 m3) Q [m³/h] 50 Eta [%] 40 30 20 Eta 10 0 10 20 30 40 50 60 70 80 90 100 Q [US GPM] P1 TM02 0079 0307 H [m] Note: ETA is calculated as wire-to-water efficiency. H3 B1 B 2 H1 H2 B7 B4 D1 D2 D3 TM02 0120 4301 M NPT 1/4 D7 D6 L3 L1 D4 D5 B5 Dimensions Model UP 43-70 L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 [in] 8.50 4.25 5.25 5.56 2.94 2.94 3.13 2.63 9.63 12.23 1.63 2.31 [mm] 216 108 133 141 75 75 79 67 244 311 41 59 Product numbers D4 D5 87 121 13 D6 D7 2.06 2.50 52 64 M M12 Connections Product number Model type Cast Iron UP 43-70 (1 ph) 96439644 Max amps [A] P Max [Watts] 115V 230V 3.4 1.8 Voltage [V] 115/230 Electrical data 58 D3 3.42 4.75 0.50 400 Flange size 1.50" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 UP, UPS Series 200 9 UP 43-110 1 ph, 115 V / 230 V, 60 Hz 10 8 6 4 2 0 P1 [hp] 1.2 0.8 0.4 0.0 H [ft] 40 35 30 25 20 15 10 5 0 0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM] 0 5 10 15 20 Q [m³/h] P1 [W] 1000 50 Eta [%] 800 40 600 30 P1 400 20 Eta 200 10 0 0 0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM] Flow range: 15 - 105 gpm Head range: 1 - 37 ft Motor: 2-pole 0.75 Hp Max. liquid temp (Open): +140 °F Max. liquid temp.: +230 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 33.1 lbs (15.0 kg) Gross wt.: 41.2 lbs (18.7 kg) Shipping volume: 1.70 ft3 (0.048 m3) TM02 0076 0307 H [m] 12 Curve charts and technical data UP 43/110, 1 ph, 115 V / 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H3 B1 B 2 H1 H2 B7 B4 D1 D2 D3 TM02 0120 3902 M NPT 1/4 D7 D6 L3 L1 D4 D5 B5 Dimensions Model UP 43-110 L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 [in] 8.50 4.25 5.25 5.56 2.94 2.94 3.13 2.63 9.63 12.23 1.63 2.94 [mm] 216 108 133 141 75 75 79 67 244 311 41 75 Product numbers D3 D4 D5 3.42 4.75 0.50 87 121 13 D6 D7 2.06 2.50 52 64 M M12 Connections Product number Model type Cast Iron UP 43-100 (1 ph) 96436943 Voltage [V] Flange size 1.50" non ANSI 2 bolt w/ (2) 0.5" dia. holes Flange type GF 40/43 115/230 Electrical data Max amps [A] P Max [Watts] 115V 230V 4.9 2.5 570 59 UP 53-45 Curve charts and technical data UP, UPS Series 200 9 UP 53-45, 1 ph, 115 V / 230 V, 60 Hz 1 ph, 115 V / 230 V, 60 Hz H [m] Flow range: 15 - 100 gpm Head range: 1 - 23 ft 20 Motor: 2-pole 0.50 Hp 16 Max. liquid temp (Open): +140 °F 12 Max. liquid temp.: +230 °F Min. liquid temp.: +32 °F H [ft] 24 6 4 8 2 4 0 0 0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM] 0.6 0.4 0.2 0.0 145 psi Net wt: 44.4 lbs (20.2 kg) Gross wt.: 63.5 lbs (23.8 kg) Shipping volume: 2.10 ft3 (0.06 m3) Net wt. bronze: 49.2 lbs (22.3 kg) Gross wt. bronze: 57.1 lbs (25.9 kg) Shipping volume bronze: 2.10 ft3 (0.06 m3) TM03 5370 0307 0 5 10 15 20 Q [m³/h] P1 [W] 500 50 Eta [%] P1 400 40 300 30 200 20 Eta 100 10 0 0 0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM] P1 [hp] Max. system pressure: Note: ETA is calculated as wire-to-water efficiency. H3 B1 B 2 H1 D4 H2 D3 B7 D5 L3 M TM03 7230 1608 L1 D6 D7 D1 B4 NPT 1/4 D2 B5 Dimensions Model UP 53-45 L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 [in] 9.88 5.00 5.25 5.56 3.56 2.94 4.75 2.94 9.88 12.86 2.06 4.19 5.00 6.00 0.63 [mm] 251 127 133 141 90 75 121 75 251 327 52 106 127 Product numbers Product number Cast Iron Bronze 96633576 96633578 Electrical data Max amps [A] 60 D4 152 D5 16 D6 D7 3.50 4.00 89 102 M M12 Connections Model type UP 53-45 (1 ph) D3 P Max [Watts] 115V 230V 3.5 1.9 360 Voltage [V] 115/230 Flange size Flange type 2.0",2.5",3.0" non ANSI 4 bolt w/ (4) 0.63" dia. holes GF 53 UP, UPS Series 200 9 UP 53-46 1 ph, 115 V / 230 V, 60 Hz H [m] Flow range: 15 - 105 gpm Head range: 1 - 37 ft 20 Motor: 2-pole 0.75 Hp 16 Max. liquid temp (Open): +140 °F H [ft] 24 6 4 12 8 2 4 0 0 0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM] 0.6 0.4 0.2 0.0 +230 °F Min. liquid temp.: +32 °F Max. system pressure: 145 psi Net wt: 44.5 lbs (20.2 kg) Gross wt.: 63.5 lbs (23.8 kg) Shipping volume: 2.10 ft3 (0.06 m3) Net wt. bronze: 49.2 lbs (22.3 kg) Gross wt. bronze: 57.1 lbs (25.9 kg) Shipping volume bronze: 2.10 ft3 (0.06 m3) TM03 5371 0307 0 5 10 15 20 Q [m³/h] P1 [W] 500 50 Eta [%] P1 400 40 300 30 200 20 Eta 100 10 0 0 0 10 20 30 40 50 60 70 80 90 100110 Q [US GPM] P1 [hp] Max. liquid temp.: Curve charts and technical data UP 53-46, 1 ph, 115 V / 230 V, 60 Hz Note: ETA is calculated as wire-to-water efficiency. H3 B1 B 2 H1 D4 H2 D3 B7 D5 L3 M TM03 7230 1608 L1 D6 D7 D1 B4 NPT 1/4 D2 B5 Dimensions Model UP 53-46 L1 L3 B1 B2 B4 B5 B7 H1 H2 H3 D1 D2 D3 D4 D5 D6 D7 [in] 9.88 5.00 5.25 5.56 3.56 2.94 4.75 2.94 9.88 12.86 2.06 4.19 5.00 6.00 0.63 3.50 4.00 [mm] 251 127 133 141 90 75 121 75 251 327 52 106 127 152 16 89 102 Product numbers M12 Connections Product number Model type UP 53-46 (1 ph) M Cast Iron Bronze 96633591 96633592 Voltage [V] Flange size Flange type 2.0",2.5",3.0" non ANSI 4 bolt w/ (4) 0.63" dia. holes GF 53 115/230 Electrical data Max amps [A] P Max [Watts] 115V 230V 3.9 2.1 420 61 UP, UPS Series 200 10 Accessories and spare parts 10. Accessories and spare parts Packaged fitting sets Pump connection Pipe connection type & size Product number Approx. ship. wt. (lb/oz.) 3/4 519601 2 lb 4 oz. 1 519602 2 lb 4 oz. 1-1/4 519603 2 lb 2 oz. NPT Flange sets Cast iron GF 15/26 flange 1-1/2 519604 2 lb 2 oz. 1-1/2 539605 2 lb 7 oz. 2 96409354 6.5 lb 2 91584910 12 lb GF 53 flange 2-1/2 91584911 12 lb 3 91584912 12 lb GF 65 flange 2-1/2 559601 16 lb GF 80 flange 3 569601 19 lb GF 100 flange 4 579801 33 lb 3/4 519651 2 lb 2 oz. 1 519652 2 lb 3 oz. 1-1/4 96409356 2 lb 1 oz. GF 40/43 flange GF 50 flange GF 15/26 flange Bronze GF 40/43 flange 1-1/2 539615 3 lb GF 50 flange 2 96409355 6.3 lb 2 91584913 12 lb GF 53 flange 2-1/2 91584914 12 lb 3 91584915 12 lb GF 80 flange 3 569611 20 lb GF 100 flange 4 96409357 30 lb Flange sets include: 2 each - flanges, gaskets, bolts with nuts. Flange adapter Terminal box electrical components 62 For use with these pumps Description 1-phase x 115/230 V UPS 3-phase x 208-230 V UPS Product number Speed plug for 3-speed 96401124 96401001 1-phase x 115 V UPS 1-phase x 230 V UPS 3-phase x 208-230 V UPS Power head relay module 96409246 96409247 96409250 1-phase x 115 V 1-phase x 230 V 3-phase x 208-230 V Protection module service 96427457 96427458 96427459 UP, UPS Series 200 11 Further documentation 11. Further documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: • Catalog • Literature • Service • Sizing • Replacement • CAD drawings. Catalog This section is based on fields of application and pump types, and contains • technical data • curves (QH, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation • product photos • dimensional drawings • wiring diagrams • quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as • product guides • installation and operating instructions • service documentation, such as Service kit catalog and Service kit instructions • quick guides • product brochures, etc. Service This section contains an easy-to-use interactive service catalog. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 63 UP, UPS Series 200 11 Further documentation Sizing 0 1 This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to • select the most suitable and efficient pump for your installation • carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. • analyse your selected pump via the built-in life cycle cost tool • determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings: • .dxf, wireframe drawings • .dwg, wireframe drawings. 3-dimensional drawings: • .dwg, wireframe drawings (without surfaces) • .stp, solid drawings (with surfaces) • .eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 14 WinCAPS CD-ROM 64 65 66 67 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence Subject to alterations. L-UPS-PG-01 0612 The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide. ECM: - GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Canada Phone: +1-905 829 9533 Telefax: +1-905 829 9512 Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L. Mexico 66600 Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Create Date : 2012:06:19 19:12:22Z Creator : FrameMaker 10.0 Modify Date : 2014:09:15 08:44:18-04:00 Language : en XMP Toolkit : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03 Creator Tool : FrameMaker 10.0 Metadata Date : 2014:09:15 08:44:18-04:00 Producer : Acrobat Distiller 10.0.0 (Windows) Format : application/pdf Title : untitled Document ID : uuid:8de25195-cd5b-4ac8-9bee-fcb8e7bdce81 Instance ID : uuid:fb3408fe-8eb5-4830-b800-cd04fa66c48d Page Mode : UseOutlines Page Count : 68EXIF Metadata provided by EXIF.tools