SECTION: 2.30.040

Product information presented
here reflects conditions at time
of publication. Consult factory
regarding discrepancies or
inconsistencies.

FM0494
0211
Supersedes
0110
MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

COMPARE THESE FEATURES

UL

•

Non-clogging vortex impeller.

•

Durable cast construction. Cast iron switch
case, motor and pump housing, base and
impeller. No sheet metal parts to rust or
corrode. All cast iron class 25-30 25000#
tensile strength.

•
•

*

R

Stainless steel screws, bolts, float rod, handle,
guard and arm and seal assembly.
Shaft Seal - Carbon & ceramic rotary face
seal, with stainless steel wetted parts.

•

UL Listed 3-wire neoprene cord and plug.
10 ft. standard for automatic.
15 ft. standard for nonautomatic.

•

Upper sleeve bearing and lower ball bearing
running in a bath of oil.

•

Maximum temperature for sewage or
dewatering 130°F (54°C).

•

Motor - 60 Hz, 1750 RPM, oil-filled,
hermetically sealed, automatic reset thermal
overload protected (1 Ph and Auto 3 Ph).

•

All models are available in 2" or 3" discharge.

•

All models pass 2 inch spherical solids.

•

Automatic units available with float operated,
submersible (NEMA 6) mechanical switch.
Available in both 1 and 3 Phase Units.**

•

Corrosion resistant powder coated epoxy
finish.

•

On point 15¼", Off point 5¼".

•

Major width 13 9/16". Major height 18 13/16".
(Single seal pumps)

visit our web site:
www.zoeller.com

282 - 284 Single Seal Series
4282 - 4284 Double Seal Series

Tested to UL Standard UL778

(For Pump Prefix Identification see News & Views 0052)

*
R

Certified to CSA Standard C22.2 No. 108

“WASTE-MATE”
SUBMERSIBLE

SEWAGE

OR DEWATERING PUMP
2" OR 3" FLANGED DISCHARGE • PASSES 2" SOLIDS

AUTOMATIC THREE
PHASE
PUMP**

SINGLE
SEAL
PUMP

DOUBLE
SEAL
PUMP

MODELS 4282-4284
DOUBLE SEAL PUMPS (nonauto only)
• Protects motor from seal leaks.
• Improved bearing lubrication.
• Helps eliminate seal and bearing damage from
dry runs.
• Major width 13 9/16". Height 21 7/16".

MODELS AVAILABLE

NOTE: The sizing of effluent systems normally requires
variable level float(s) controls and properly sized basins
to achieve required pumping cycles or dosing timers with
nonautomatic pumps.

• Automatic or Nonautomatic with single seal • Single phase or three phase motors
avilable.
• Nonautomatic with double seals
• See selection chart for specifications or
• 2" or 3" discharge.
specific models.
*NOTE: No UL Listing or CSA Certification for 200V 1Ph or Extra Duty (ED) pumps.
See back page for UL & CSA Listings.
**THREE PHASE AUTOMATIC UNITS AVAILABLE IN 230V SINGLE SEAL ONLY.

© Copyright 2011 Zoeller Co. All rights reserved.

FEET

METERS

MODELS

PUMP PERFORMANCE CURVE
MODELS 282/4282/284/4284

Feet
Meters
5
1.5
10
3.0
15
4.6
20
6.1
25
7.6
30
9.1
Shut-off Head

40

12

35
10

TOTAL DYNAMIC HEAD

30
8

25

Single Seal Design
Weight 81-86 lbs.

282/4282

284/4284

Gal.
Liters
127
481
96
363
64
242
34
129
6
23
--26 ft. (7.9m)

Gal.
Liters
179
678
157
594
133
503
106
401
73
276
42
159
35 ft. (10.7m)

284
4284

5

8 9/16
6 5/16

5

2" NPT
OR
3" NPT
FLANGE AVAILABLE

009927B

20

6

15
282
4282

4
10
2
5

0

18 13/16
20

40

60

80

160

80

100

120

140

160

180

200

GALLONS
LITERS

0

240

320

400

480

560

640

720

6 1/4

FLOW PER MINUTE

009927A

SK1023

CONSULT FACTORY FOR SPECIAL APPLICATIONS
•

Three phase pumps are available in 200V, 230V, or 460V. 230V three phase is
available in automatic and nonautomatic models.
Electrical alternators, for duplex systems, are available and supplied with an alarm.
Mechanical alternators, for duplex systems, are available with or without alarm
switches.
Combination starters are available.
Variable level control switches are available for controlling single and three phase
systems.
Double piggyback variable level float switches are available for variable level long
cycle controls.
Long cords are available in lengths or 25 - 35 - 50 feet.
Simplex and duplex basins are available.
Refer to FM1922 and FM0806 for temperatures over 130°F.

•
•
•
•
•
•
•
•

SPECIFICATIONS
Single Seal Double Seal

Model

Model

M282
N282
D282
E282
H282
I282
J282
F282
CF282
G282
BA282
D284
E284
H284
I284
J284
F284
CF284
G284
BA284

----------N4282
----------E4282
----------*I4282
*J4282
*F4282
----------*G4282
*BA4282
----------E4284
----------*I4284
*J4284
*F4284
----------*G4284
*BA4284

*
*
*
*
*
*
*

*
*
*
*
*
*
*

Volt-Phase
115
115
230
230
200
200
200
230
230
460
575
230
230
200
200
200
230
230
460
575

1Ph
1Ph
1Ph
1Ph
1Ph
1Ph
3Ph
3Ph
3Ph
3Ph
3Ph
1Ph
1Ph
1Ph
1Ph
3Ph
3Ph
3Ph
3Ph
3Ph

Mode
Automatic
Nonauto
Automatic
Nonauto
Automatic
Nonauto
Nonauto
Nonauto
Automatic
Nonauto
Nonauto
Automatic
Nonauto
Automatic
Nonauto
Nonauto
Nonauto
Automatic
Nonauto
Nonauto

CONTROL SELECTION
Cord
Amps HP Lgth. Simplex
Duplex
10.3
10.3
5.0
5.0
6.1
6.1
3.6
3.0
3.0
1.7
1.4
8.9
8.9
9.3
9.3
5.5
5.0
5.0
2.6
2.2

1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1/2
1
1
1
1
1
1
1
1
1

10
15
10
15
10
15
15
15
15
15
15
10
15
10
15
15
15
15
15
15

1
2 or 3
1
2 or 3
1
3
3
3
1
3
3
1
2 or 3
1
3
3
3
1
3
3

Double Seal Design
Weight 88-91 lbs.

Listings
CSA UL

------4
------4
------4
4
4
------4
4
------4
------4
4
4
------4
4

Y
Y
Y
Y
N
N
Y
Y
N
Y
Y
Y
Y
N
N
Y
Y
N
Y
Y

Y
Y
Y
Y
N
N
Y
Y
Y
Y
N
Y
Y
N
N
Y
Y
Y
Y
N

SK1414

SELECTION GUIDE
1. Integral float operated mechanical switch, no external
control required.
2. For automatic use single piggyback variable level float
switch or double piggyback variable level float switch.
Refer to FM0477.
3. See FM1228 for correct model of simplex control panel.
4. See FM0712 for correct model of duplex control panel.

* No Molded Plug

For information on additional Zoeller products refer to catalog on Piggyback Variable Level Float Switches,
FM0477; Electrical Alternator, FM0486; Mechanical Alternator, FM0495; Sump/Sewage Basins, FM0487;
Simplex Pump Control, FM1596; Alarm Systems, FM0732; and Disconnect/Rail Systems, FM0787.

All installation of controls, protection devices and wiring should be done by a qualified licensed
electrician. All electrical and safety codes should be followed including the most recent National
Electric Code (NEC) and the Occupational Safety and Health Act (OSHA).

RESERVE POWERED DESIGN

For unusual conditions a reserve safety factor is engineered into the design of every Zoeller pump.
© Copyright 2011 Zoeller Co. All rights reserved.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.6
Linearized                      : Yes
Author                          : mikem
Create Date                     : 2011:02:07 13:33:38-05:00
Modify Date                     : 2013:04:15 09:00:56-04:00
Subject                         : FM0494
XMP Toolkit                     : Adobe XMP Core 5.4-c005 78.147326, 2012/08/23-13:03:03
Creator Tool                    : PScript5.dll Version 5.2.2
Metadata Date                   : 2013:04:15 09:00:56-04:00
Format                          : application/pdf
Title                           : fm0494-282/284 Catalog Sheet
Creator                         : mikem
Description                     : FM0494
Producer                        : Acrobat Distiller 8.2.2 (Windows)
Document ID                     : uuid:67485910-785a-4934-930e-877350db3735
Instance ID                     : uuid:5ac0b99d-c5ac-43f2-8f8f-9f4d9623015d
Page Count                      : 2
EXIF Metadata provided by EXIF.tools

Navigation menu