1993 1 Zoeller 10 0512 Brochure Fm1232 840 Catalog Sheet User Manual
536725 2 Zoeller 840 Grinder Pump Accessories 536725_2_Zoeller 840 Grinder Pump Accessories
536725 2 Zoeller 840 Grinder Pump Accesories 536725_2_Zoeller 840 Grinder Pump Accesories
User Manual: Pump 1993 1 Zoeller 10-0512 Brochure
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
SECTION: 2.50.040 Product information presented here reflects conditions at time of publication. Consult factory regarding discrepancies or inconsistencies. FM1232 0906 Supersedes 0106 MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347 SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961 (502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624 visit our web site: www.zoeller.com PUMP SYSTEMS AND REVERSING CONTROLS 840 SERIES FEATURES: • • • • • • • • • • • • • • Durable Heavy Duty Finned Cast Iron Construction. 2 HP, 60 Hz, 3450 RPM. Oil-Filled - Hermetically Sealed Motor with Class F Insulation. Hardened Stainless Steel Cutter and Disc. Cutters Protected from Abrasive Solids. Cutters can automatically alternate direction to enhance blade life and free hang-ups. (automatic or manually) Stainless Steel Screws, Bolts, and Lifting Bail. Easily adapts to many existing competitors’ rail systems. Tandem seals with leak detection. Automatic Thermal Overload Protection (Single Phase) Thermal Sensor Protection (Standard on 3 Phase) Legs provide for free standing installation. Preassembled Systems Available. Corrosion resistant powder coated epoxy finish. UL R Tested to UL Standard UL778 and Certified to CSA Standard C22.2 No. 108 Note: All variable level float switches in this section are mechanically activated and do not contain mercury. Product may not be exactly as pictured. © Copyright 2006 Zoeller Co. All rights reserved. GRINDER SYSTEMS (A) GRINDER MODEL - 840 2 HP, 1¼" N.P.T. VERTICAL DISCHARGE - 20 FT. CORDS P/N WGT. MODEL VOLTS PH AMP 840-0004 137 E840 230 1¤ 17.2 840-0005 137 I840 200 1¤ 20.0 840-0006 132 F840 230 3 10.8 840-0007 132 J840 200 3 12.3 840-0008 132 G840 460 3 5.5 840-0009 132 BA840 575 3 4.5 (B) CONTROL PANELS SIMPLEX NEMA 4X MODEL E or I 840 E or I 840 F or J 840 G840 BA840 ¤ Single phase units require a set of capacitors and relay starting components. (B) (C)* VARIABLE LEVEL FLOAT SWITCHES INDOOR SYSTEM 3 Switches and Weights without Brackets P/N 10-0347 WGT. 9.5 4 Switches and Weights without Brackets P/N 10-0348 WGT. 13.0 OUTDOOR SYSTEM 3 Switches with Weights and Brackets P/N 10-0329 WGT. 10.0 4 Switches with Weights and Brackets P/N 10-0330 WGT. 14.0 BRACKET VARIABLE LEVEL FLOAT SWITCH MODEL E840 I840 F840 J840 G840 BA840 AUTOMATIC P/N WGT. 10-0352 8 10-0352 8 10-0353 6 10-0353 6 10-0354 12 10-0355 12 MANUAL P/N WGT. 10-0360 7 10-0360 7 10-0361 5 10-0361 5 10-0362 5 10-0362 5 * These control boxes consist of the reversing mechanisms and capacitors (1Ph units) only. They will not control pumps. Refer to Section B for complete system controls. For duplex applications use two simplex reversing control boxes. (For pump prefix identification see News & Views 0052) SK1328 (D) SIMPLEX REVERSING CONTROL BOXES* Note: All variable level float switches in this section are mechanically activated and do not contain mercury. CHECK VALVES 1¼" Cast Iron NPT Female P/N 30-0163 WGT. 7.5 1½" Cast Iron NPT Female P/N 30-0164 WGT. 7.5 2" Cast Iron NPT Female P/N 30-0152 WGT. 10.0 P/N 10-0397 10-0512* 10-0398 10-0399 10-0400 WGT. 21 23 21 21 21 CONTROL PANEL STANDARD FEATURES: • Nema 4X Outdoor Rating • Starting, Control, and Alarm Circuits • Circuit Breaker and Rated Motor Contactor (single phase) • Capacitors and Motor Starting Relay on Single Phase • Motor Protective Switch (circuit breaker/adj overloads) and Rated Motor Contactor (three phase) • Alternating Circuit (Duplex) • Automatic Reversing Circuit • High Water Alarm Light • Internal Seal Leak Light • HOA Switches and Pilot Light(s) • Terminal Strips • Thermal Cut-Out Circuit (three phase only) • Padlock Hasp • Capacitors/Start Relay (single phase) • UL Listed **Requires Circuit in Control Panel to Function WEIGHT WGT. 15 17 18 18 18 *With Audible and Visible High Water Alarm STANDARD FEATURES: • Reversible Cutter Action Manual/Auto** • 1¼" NPT Vertical Discharge • Carbon/Ceramic Tandem Seals • Thermal Sensors** (O.L. on 1Ph) • Moisture Probes** • Balanced Bronze Impellers • Stainless Steel Cutter and Plate (R-C 55-60) • Stainless Steel Shaft • Stainless Steel Lifting Bail • Corrosion resistant powder coated epoxy paint • 20 ft. Power Cord - 20 ft. Sensor Cord • UL Listed OPTIONS: Extended Cord Lengths Anti-Siphon Device CORD P/N 10-0393 10-0420* 10-0394 10-0395 10-0396 DUPLEX NEMA 4X OPTIONS: Audible High Water Alarm Flasher for High Water Alarm Light Manual Reset of High Water Alarm Intrinsically Safe Relays Manual Reversing Switch Elapsed Time Meters Dry Auxiliary Contact For other options, consult factory Maximum Temperature for Sewage 130°F (54°C) FOR GRINDER PUMP ONLY Single Phase Pump Requires Two Capacitors and a Motor Starting Relay Factory Mounted in a Nema 4X starter pack. P/N 10-0379 WGT. 7 Two Capacitors and Motor Starting Relay shipped loose to be mounted in existing panel. P/N 10-0380 WGT. 2 THE MODEL 840 GRINDER WILL FIT ON MYER’S RAIL P/N RWG125 (1 Required) & RWGD125 (2 required) by using Zoeller’s Adapter. P/N 10-0381 WGT. 3 Hydro-O-Matic’s Hydr-O-Rail® bolts directly to Model 840 by using base adapter. Specify when ordering. (E) JUNCTION BOXES - TYPE 4X SIMPLEX 5 Holes with Seals for (1) Power Cord, (1) Sensor Cord, (3) Float Switch Cords. P/N 10-0331 WGT. 2.5 3 Float System DUPLEX 8 Holes with Seals for (2) Power Cords, (2) Sensor Cords, (3 or 4) Float Switch Cords. P/N 10-0332 WGT. 2.5 3 Float System P/N 10-0421 WGT. 2.5 4 Float System FEMALE THREADS BOTH ENDS SK1330 SK1331 © Copyright 2006 Zoeller Co. All rights reserved. (F) • • • • • • • • • • • INDOOR BASIN, COVER, AND HARDWARE - PREPACKAGED STANDARD EQUIPMENT Fiberglass Basin Rust Resistant Steel Cover(s) (epoxy coated only) Inspection Plate Individual Pump Covers 3" Adaptaflex Vent Seal 1¼" Adaptaflex Discharge Pipe Seal(s) Cord Seal(s) 1-4" Fiberglass Hub with rubber grommet Pump Support Hardware 1¼" Check Valve(s) Ball Valve(s) SIMPLEX 24" x 36" TO CONTROL PUMPS NOT INCLUDED P/N 32-0005 WGT. 107 DUPLEX 30" x 36" P/N 32-0006 WGT. 154 3-Float System 30" x 36" P/N 32-0007 WGT. 154 4-Float System ALARM OVERRIDE WGT. 2.0 WGT. 2.5 SK1326 OUTDOOR BASIN, COVER, AND RAIL SYSTEM ASSEMBLIES - STANDARD EQUIPMENT RAIL SYSTEMS - (FIELD INSTALLED) Intermediate Stabilizer Bracket for every 12' of depth. Galvanized P/N 39-0089 WGT. 6.0 Stainless Steel P/N 39-0090 WGT. 6.0 2.0 OFF Fiberglass Basin with Anti-flotation Ring 1¼" Galvanized pump discharge piping to disconnect 1¼" PVC Discharge Pipe from Disconnect 1¼" Adaptaflex Discharge Pipe Seal Stainless Steel Square Guide Rail 1' Pull Rod 8' SS Lifting Cable for basin depths to 84" (12’ SS Lifting Cable for basin depths of 96") • 1¼" PVC Ball Valve(s) • 1¼" C.I. Check Valve(s) • 1-4" Rubber Inlet Pipe Seal (Field Installed) • Fiberglass Cover SIMPLEX 24" x 48" P/N 33-0022 WGT. 206 24" x 60" P/N 33-0023 WGT. 219 24" x 72" P/N 33-0024 WGT. 233 24" x 84" P/N 33-0057 WGT. 264 24" x 96" P/N 33-0025 WGT. 277 DUPLEX 36" x 48" P/N 33-0034 WGT. 367 36" x 60" P/N 33-0035 WGT. 389 36" x 72" P/N 33-0036 WGT. 472 36" x 84" P/N 33-0059 WGT. 499 PUMP NOT INCLUDED 36" x 96" P/N 33-0037 WGT. 525 SK1607 OPTIONS: • All SS Fitted • Larger Diameter or Deeper Basins (Allow for Overhead Clearance) E-Z out Rail System for 1¼" pump discharges (Rail System discharge is 2" NPT male thread) Galvanized Fitted P/N 39-0087 WGT. 43 Stainless Steel Fitted P/N 39-0088 WGT. 43 WGT. ON • • • • • • • (H) BALL VALVE 1¼" IPS P/N 30-0165 1½" IPS P/N 30-0166 2" IPS P/N 30-0167 36 30 (G) (I) UPPER RAIL SUPPORT GUIDE RAIL (NOT INCLUDED) GUIDE PLATE RAIL PLATE ELBOW THREADED MALE CONNECTION Square Guide Rail System for systems less than 96" deep) BASIN DEPTH 48" P/N 39-0054 WGT. 90.5 60" P/N 39-0055 WGT. 94.5 72" P/N 39-0056 WGT. 98.5 Fits both round and square basins Includes Square Guide Rail. Basins over 72" deep require one additional angle arm bracket. P/N 39-0070 WGT. 11 SK1333 (J) PULL RODS FOR SQUARE GUIDE RAIL SYSTEMS ONLY (Field Installed Systems) 1 Ft. “L” P/N 39-0069 2½ Ft. “L” P/N 39-0006 3½ Ft. “L” P/N 39-0007 4½ Ft. “L” P/N 39-0008 5½ Ft. “L” P/N 39-0009 WGT. 0.5 WGT. 1.0 WGT. 1.5 WGT. 1.5 WGT. 2.0 L SK2283 (K) SS LIFTING CABLE (Field Installed Systems) 8 Ft. P/N 12 Ft. P/N 16 Ft. P/N 20 Ft. P/N 24 Ft. P/N 39-0031 WGT. 1.0 39-0032 WGT. 1.0 39-0033 WGT. 1.0 39-0034 WGT. 1.0 39-0035 WGT. 1.0 DISCONNECT ELBOW SK1859 © Copyright 2006 Zoeller Co. All rights reserved. SK1626 SK1335 PREPACKAGED AND JOB READY SYSTEMS SIMPLEX REQ. 1 Grinder 1 Simplex Control Panel 1 Variable Level Fl. Sw. Assm. 1 Basin, Cover and Hardware INDOOR P/N ___________ (A) P/N ___________ (B) P/N ___________ (C) P/N ___________ (F) SIMPLEX REQ. 1 Grinder 1 Simplex Control Panel 1 Variable Level Fl. Sw. Assm. 1 J-Box 1 Basin, Cover and Rail System DUPLEX REQ. 2 Grinders 1 Duplex Control Panel 1 Variable Level Fl. Sw. Assm. 1 Basin, Cover and Hardware OUTDOOR P/N ___________ (A) P/N ___________ (B) P/N ___________ (C) P/N ___________ (E) P/N ___________ (G) P/N ___________ (A) P/N ___________ (B) P/N ___________ (C) P/N ___________ (F) DUPLEX REQ. 2 Grinders 1 Duplex Control Panel 1 Variable Level Fl. Sw. Assm. 1 J-Box 1 Basin, Cover and Rail System P/N ___________ (A) P/N ___________ (B) P/N ___________ (C) P/N ___________ (E) P/N ___________ (G) FIELD MOUNT SYSTEMS 11 21/32 4 1/16 SIMPLEX 4 1/16 8 1/8 24 7/32 (A) (B) (C) (E) (H) (H) (J) (K) MADE IN U.S.A. 21 3/32 SK1323 SK1322 DUPLEX PUMP PERFORMANCE CURVE MODEL 840 110 P/N _________ P/N _________ P/N _________ P/N _________ P/N _________ P/N _________ P/N _________ P/N _________ (A) (B) (C) (E) (H) (H) (J) (K) * Required for basin depths over 72" (Square Guide Rail) and over 12' (E-Z Out Rail). Allow for overhead clearances. ** For Square Guide Rail only. Access Doors Available on Field Mount Systems - Consult Factory Special Basin Configurations - Consult Factory Junction Box Mounting & Assembly - Consult Factory 32 100 28 24 TOTAL DYNAMIC HEAD REQ. 2 Grinders 1 Duplex Control Panel 1 Variable Level Fl. Sw. Assm. 1 Junction Box 2 Rail Systems 2 Angle Arm/Intermediate Bracket* 2 Pull Rods** 2 S.S. Lifting Cables 5 3/8 4 9/16 FEET P/N _________ P/N _________ P/N _________ P/N _________ P/N _________ P/N _________ P/N _________ P/N _________ METERS REQ. 1 Grinder 1 Simplex Control Panel 1 Variable Level Fl. Sw. Assm. 1 Junction Box 1 Rail System 1 Angle Arm/Intermediate Bracket* 1 Pull Rod** 1 S.S. Lifting Cable 6 15/32 90 80 70 20 60 16 12 50 40 30 8 20 4 10 0 Manufacturers of . . . 5 10 15 20 25 30 35 45 40 50 GALLONS LITERS 0 40 80 120 160 FLOW PER MINUTE 009960A © Copyright 2006 Zoeller Co. All rights reserved.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes XMP Toolkit : 3.1-702 Producer : Acrobat Distiller 7.0.5 (Windows) Create Date : 2006:08:29 10:22:44-04:00 Creator Tool : Windows NT 4.0 Modify Date : 2006:08:29 10:24:03-04:00 Metadata Date : 2006:08:29 10:24:03-04:00 Format : application/pdf Title : fm1232-840 Catalog Sheet Description : FM1232 Creator : mikem Document ID : uuid:32731bf7-28af-43d1-9de2-1287b2887cd6 Instance ID : uuid:06d02bc7-cc81-41b1-903a-37dd832ece1c Page Count : 4 Subject : FM1232 Author : mikemEXIF Metadata provided by EXIF.tools