535254 3 Grundfos Products Overview User Manual
535250 3 Grundfos Products Overview 535250_3_Grundfos Products Overview
535256 3 Grundfos Products Overview 535256_3_Grundfos Products Overview
535252 3 Grundfos Products Overview 535252_3_Grundfos Products Overview
535253 3 Grundfos Products Overview 535253_3_Grundfos Products Overview 535253_3_Grundfos Products Overview pdf pumpproducts
535251 3 Grundfos Products Overview 535251_3_Grundfos Products Overview 535251_3_Grundfos Products Overview pdf pumpproducts
User Manual: Pump 535254 3 Grundfos Products Overview
Open the PDF directly: View PDF .
Page Count: 48
Download | |
Open PDF In Browser | View PDF |
GRUNDFOS PRODUCT GUIDE Domestic water supply BMQE, MQ, Jets 60 Hz Domestic water supply Table of contents 1. 2. 3. 4. 5. 2 Grundfos DWS family 3 DWS applications DWS product selection 3 4 BMQE 5 Product introduction Product overview Construction Operating conditions Installation Quick selection guide Curve charts and technical data Accessories, BMQE 5 7 8 10 10 12 12 18 MQ 19 Product introduction Product overview Construction Operating conditions Installation Selection of product Curve charts and technical data Accessories, MQ 19 21 22 24 24 24 25 28 JP Jet Pumps 29 Product introduction Product overview Construction Operating conditions Selection Selection of pumps Installation Curve charts and technical data Dimensions and weights Electrical data Approvals 29 31 34 35 35 35 35 36 41 45 45 Further documentation 46 WebCAPS WinCAPS 46 47 1 Domestic water supply DWS applications The Grundfos DWS family includes pumps to fit most applications including: • Constant pressure systems (BMQE) • flow-based pressure boosting (MQ) • rain water harvesting (MQ) • pressure-switch-based boosting (Jet) • suction lift (Jet). Flow-based pressure boosting With flow-based pressure boosting, the pump starts automatically when water is consumed and stops automatically when the consumption ceases. This is accomplished via a flow switch connected to a printed circuit board (PCB). The pump will produce pressure in relation to the flow rate with any incoming pressure cumulative to the total discharge pressure (fig. 2). Incoming psi (city water pressure) Fig. 2 Outgoing psi = Incoming psi + performance TM01 9873 The Grundfos Domestic Water Supply (DWS) family of pumps includes: • BMQE Constant Pressure System • MQ Flow Based Pressure System • Jet pumps. This product guide offers information about each of these product lines. Grundfos DWS family 1. Grundfos DWS family Flow-based pressure boosting C Rain water harvesting Product Application BMQE MQ Jet Constant pressure system - - Flow-based pressure boosting - - Rain water harvesting - - Suction lift - Pressure-switch-based boosting - - Rain water harvesting is a way to store rain water for future use — for example, watering a garden. Rain water is collected from the roof of a home and collected into a storage container. Pull a suction lift using a non-collapsible suction line from the storage container or connect the inlet of the pump to a spigot at the bottom of the collection barrel for flooded suction. Constant pressure systems In constant water pressure systems, only the required discharge pressure needs setting (fig. 1). Cut-in and cut-out pressures do not play a role in this system. Discharge pressure can be set from 40 to 100 psi, according to individual needs and piping system limitations. Suction lift High pressure water from the drive pipe passes through the venturi and pulls water from the well into the ejector, then pushes it up to the pump. This makes it possible to push water up to the pump from depths greater than 25 feet or to boost the output from a shallow well pump to higher pressures. Drive pipe Suction pipe In a constant pressure system, pressure does not vary in relationship to consumption Nozzle Inlet Fig. 3 TM05 0823 1611 Time Fig. 1 TM04 9463 4310 Head Venturi Suction lift pressure boosting Pressure-switch-based boosting Pressure switches are used to control pump operation. These switches have a cut-in pressure and a cut-out pressure to turn the pump on and off respectively. 3 1 Domestic water supply Grundfos DWS family DWS product selection Matching consumption and pump capacity Selecting the right pump is a matter of matching water consumption with pump capacity. For best performance, avoid installing an undersized or oversized pump. Consumption may vary greatly depending on housing standards and lifestyle. For example, lawn sprinkler systems in the summer can increase consumption. Pump selection Pump selection is based on the water demand and required system head. The water demand depends on the number of consumers connected to the system. Head can either be expressed in feet or psi. Head refers to static head, pressure head, and friction head. For assistance with pump selection, refer to the WebCAPS product selection program; a link to CAPS may be found on the Grundfos website. Piping In any water supply system, the sizing and choice of materials of the pipework has an impact on the choice of pumps and on the cost. Piping takes into account the system head as referred to in Pump Selection. Static head is the distance from the ground water level to the uppermost tap. Pressure head is the system pressure the user wants to achieve. In most residential application this pressure is approximately 60 psi. Friction head depends on the pipe size, type and length. When calculating friction loss remember to allow for deterioration in the piping schematic, since all water pipes will eventually become coated with rust, lime deposits, etc. Flow velocity in the piping must be kept low as noise can occur due to turbulence in elbows and valves or from water hammer. Fitting a pressure relief valve in the discharge piping is recommended to protect the piping from over-pressure due to system malfunction. Pressure tanks A pressure tank should be installed in order to minimize the number of pump starts and stops in the water supply system, and to reduce problems with water hammer in the pipework. Tanks are included with the BMQE Constant Pressure System and the MQ. The BMQE system has an external tank. The MQ has an internal tank. Jet pumps, however, may require the addition of a tank depending upon the application. 4 Pressure switches Pressure switches are used to control pump operation. These switches have a cut-in pressure and a cut-out pressure to turn the pump on and off. The BMQE Constant Pressure System includes a pressure transducer for constant pressure. The MQ has a built-in pressure switch. Jet pumps have an attached pressure switch. Valves Check valves A check valve is a mechanical device which normally allows fluid to flow through in only one direction. The BMQE Constant Pressure System and the MQ have built-in check valves. For suction lift applications with the MQ, a check valve (provided) is required at the inlet. Foot Valves A foot valve is required when pulling a suction lift (shallow or deep well) with a Jet pump. This valve is installed at the end of the suction pipe to prevent back flow. The MQ will also benefit from the use of a foot valve with suction lift applications. Shut off valves Shut off valves in the piping system make it possible to drain only the part of the system that needs attention or repair. Flow control valves Flow control valves are used in applications where a set flow (gpm) is required; for example, a shower head or an irrigation system. Pressure reducing valves Pressure reducing valves are used in applications where the incoming water pressure exceeds the maximum inlet pressure of the pump as is the case with the MQ and city water pressure. The pressure reducing valve (PRV) is used inline after the city water tap and before the pump to ensure a set pressure. Pressure relief valves This valve is a spring controlled device that can be adjusted to meet the needs of the pumping system. Pressure relief valves are used in applications where high pressure can result in damage to accessories; for example, tanks with maximum pressure ratings. 2 Domestic water supply BMQE 2. BMQE Product introduction Pumped liquids TM04 9387 4010 The BMQE Constant Pressure System maintains constant water pressure under varying demand, even with multiple taps running. The BMQE is a complete pressure boosting system that includes: • pump • controller • tank • mounting brackets • pressure sensor. Fig. 4 Grundfos BMQE Constant Pressure System High-quality construction and rugged design ensure low maintenance and trouble-free operation. The system is based on the time-tested technology of the Grundfos SQE constant pressure system (for submersible applications). The pump's MSE 3 motor incorporates solid state electronics and permanent magnet motors which account for high motor efficiencies. Variable speed is offered though frequency control via the CU 301 remote status box. The system can be set to operate at any duty point in the range between minimum and maximum performance of the pump. The BMQE has built in safeties in the solid state electronics. The small footprint of the pump allows the system to be positioned either vertically or horizontally depending upon the application. Refer to the BMQE (previously EZ Boost) pages on our web site at www.grundfos.us. Applications The BMQE Constant Pressure System is suitable for: • condos • restaurants • homes • irrigation • offices • grocery applications • many other boosting applications. The BMQE Constant Pressure System is suitable for pumping water or other clean, thin, non-aggressive liquids not containing solid particles or fibers. Features and benefits With the Grundfos BMQE Constant Pressure System, constant pressure is as simple as a touch of a button on the accompanying CU 301 control unit. Features • Quick and easy installation • ready-to-use system requires minimal space • high user convenience (constant pressure regardless of consumption) • easily adjustable pressure level with push button control • continuous control and monitoring of pump operation • integrated dry-running protection • integrated overload protection • integrated protection against over-voltage and under-voltage • soft start feature. Benefits The BMQE Constant Pressure System automatically balances water surges and equalizes flow and pressure according to consumption. In other words, the system maintains a constant water pressure despite varying consumption. The pressure is registered by means of a pressure sensor and transmitted to the controller. The controller adjusts the BMQE pump performance accordingly. How the system functions When a tap is opened, the pressure in the tank will start to drop. The system maintains a constant pressure within the maximum pump performance despite varying water consumption. The pressure is registered by means of the pressure sensor, which transmits a signal to the controller. The controller adjusts the pump performance accordingly to maintain constant pressure by changing the pump speed. At low flow the pressure will drop slowly. When the pressure in the tank is 7 psi below the setpoint, the pump will start. When the pressure is 7 psi above the setpoint, the pump will stop. Even though the BMQE controller is controlling the pressure within + / - 3 psi, larger pressure variations may occur in the system. 5 2 Domestic water supply BMQE If the consumption is suddenly changed — for example, if a tap is opened — the water must start flowing before the pressure can be made constant again. Such dynamic variations depend on the pipe work, but typically they will lie between 7 and 14 psi. If the desired consumption is higher than the quantity the pump is able to deliver at the desired pressure, the pressure follows the pump curve as illustrated in the far right of fig. 5. Pressure Stop +7 PSI The pre-charge pressure of the diaphragm tank must be set to 70 % of the pressure setting in order to use the tank to the limit of its capacity. Use the values in the following table. Pre-charge pressure is measured with 0 psi in the pipeline. Dynamic variations ±7 PSI 0.8 A = Pressure setting GPM TM04 9388 4010 Controlling ±3 PSI Flow Fig. 5 The MSE 3 motors are based on state-of-the-art technology within permanent magnets (PM motor), which accounts for the high motor efficiencies. In addition, the motors have a built-in electronic unit with a frequency converter for variable frequency and soft starting. The MSE 3 motors features high efficiency within a wide load range. The high and flat efficiency curve of the PM motor enables the same motor to cover a wide power range as opposed to conventional AC motors. For BMQE pumps, this means fewer motor variants. Diaphragm tank A Start -7 PSI BMQE motor Setting (psi) Pre-charge pressure (psi) 40 28 50 35 60 42 70 49 80 56 System function At large flow rates, the pressure will drop quickly and the pump will start immediately and maintain constant pressure. When the system is running, the controller makes small adjustments to the pressure to detect whether there is consumption. If there is none, the pump will simply refill the tank and stop after a few seconds. BMQE pump The pumps used for BMQE system are modified SQE submersible pumps. The BMQE pump is an SQE pump with an MSE 3 motor. The pump and motor are centered in the 4 inch stainless steel sleeve. BMQE pumps are suitable for both continuous and intermittent operation for a variety of pressure boosting applications. 90 63 100 70 Only a 2-gallon tank (Grundfos part number 91121984) is recommended in the BMQE system. Use of a different size tank will result in pressure fluctations. Identification Type key Example Rated flow [US gpm] BMQE pump Electronically controlled pump via BMQE controller Motor [Hp] Head at rated flow [ft] BMQE controller The BMQE controller is a control and communication unit specifically developed for the BMQE booster pumps in constant pressure applications. The controller provides: • Full control of the BMQE pumps • Two-way communication with the BMQE pumps • Possibility of adjusting the pressure • Alarm indication (LED) when service is needed • The possibility of starting, stopping and resetting the pump simply by means of a push-button. The controller communicates with the pump via power line communication, meaning that no extra cables are required between the controller and the BMQE pump. The controller incorporates external signal input for pressure sensor and a pump status relay for use with devices dependant on pump status. 6 22 BMQ E 05B 120 2 Domestic water supply BMQE Product overview Performance range, BMQE 60 Hz P [psi] H [ft] H [m] BMQE 60 Hz 15 BMQE 07B-180 120 280 80 240 100 200 60 22 BMQE 10C-190 80 15 BMQE 05A-110 160 60 40 120 22 BMQE 05B-120 40 80 30 BMQE 10C-130 22 BMQE 05A-80 20 20 0 0 TM05 0676 1411 30 BMQE 05B-90 40 0 0 0 5 1 10 2 15 3 20 4 25 5 30 6 35 7 8 Q [US GPM] 9 Q [m³/h] Product range, BMQE Range BMQE 15 3 Nominal flow rate [US gpm (m h)] 15 (3.4) BMQE 22 BMQE 30 22 (5.0) 30 (6.8) Liquid temperature range [°F (°C)] +32 to +95°F (0 to +35°C) Maximum inlet pressure [psi (bar)] 217 (15) Minimum inlet pressure [psi (bar)] 8 (0.5) Maximum working pressure [psi (bar)] Maximum efficiency [%] 57 3 Flow range [US gpm (m h)] Maximum pump pressure [ft (m)/psi)] Pipe connection 347 (23) 62 60 0 to 19 (4.3) 0 to 33 (7.5) 0 to 39 (8.8) 300 (91.4)/130 290(88.4)/125 208(63.4)/90 1.25" NPT inlet / 1” NPT discharge 7 2 Domestic water supply TM04 9415 4110 BMQE System diagram Pos. Description 1 BMQE pump 2 BMQE controller 3 Diaphragm tank* 4 Pressure sensor 5 Mounting brackets 6 Flex connector** * Recommended size: 2 U.S. gal (8 liter) / 130 psi ** Not sold by Grundfos Construction Components, BMQE Pos. 8 4 5 1 2 7 3 TM05 0678 1411 6 Components, BMQE controller 6 1 Pos. 2 3 4 Description 1 Flow indicator 2 System pressure setting 3 System ON/OFF 4 Button lock indicator 5 Dry-running indicator 6 Service needed in case of: • No contact to pump • Over voltage 8 TM05 0719 1511 • Under voltage 5 • Speed reduction • Over temperature • Overload • Sensor defective Description 1 Sleeve 2 Discharge connection 3 Suction connection 4 MSE 3 motor 5 SQE pump 6 Cable entry 7 Centering device 8 Air vent screw 2 Domestic water supply BMQE Material specification Sleeve Pos. Description 90 Sleeve 91 92 Material 1a AISI Stainless steel 316 Flange Stainless steel 304 Cable entry Stainless steel/FKM 304 93 Air vent screw Stainless steel 304 94 O-ring FKM 70 14 39 14a 2 Pump Pos. Description Material 1 Valve casing Polyamide 1a Discharge chamber Stainless steel 1d O-ring NBR rubber 2 Valve cup Polyamide 3 Valve seat NBR rubber 4a Empty chamber Polyamide 6 Top bearing NBR rubber 7 Neck ring TPU / PBT 7a Lock ring Stainless spring steel 7b Neck ring retainer Polyamide 9b Chamber top Polyamide 9c Chamber bottom Polyamide 13 Impeller with tungsten carbide bearing Polyamide 14 Suction interconnector 304 18b 1d 7a 6 64 18 310 4a 30 87 9b Stainless steel 304 Stainless steel 304 16 Shaft with coupling 18 Cable guard Stainless steel 304 Screws for cable guard Stainless steel 316 30 Cone for pressure equalization Polyamide 32 Guide vanes Polyamide 39 Spring Stainless spring steel 55 Pump sleeve Stainless steel 64 Priming screw Polyamide 70 Valve guide Polyamide 86 Lip seal ring NBR rubber 87 Cone for pressure equalization complete Polyamide / NBR rubber 18b 55 1 Polyamide 14a Ring 18a 3 AISI 86 32 13 16 Sintered steel 18a 9c 7 7b BMQE pump 316LN 304 92 93 222a Motor Description Material AISI 225 201 Stator Stainless steel 304 232 202 Rotor Stainless steel 304 224 202a Stop ring PP 202b Filter Polyester 203 Thrust bearing Carbon 205 Radial bearing Ceramic 220 Motor cable with plug EPR 222a Filling plug 224 O-ring 225 Top cover 232 Shaft seal Motor liquid 91 201 94 205 202a 202b 90 MS 3: NBR MSE 3: FKM 202 FKM 220 PPS MS 3: NBR 203 MSE 3: FKM 233 SML-2 BMQE motor Key NBR = Nitrile Butadiene Rubber TPU = Thermoplastic Polyurethanes Fig. 6 BMQE sleeve TM05 0679 1411 Pos. BMQE exploded view PBT = Polybutylene Terephthalate PP = Polypropylene EPR = Ethylene Propylene Rubber FKM = Viton PPS = Polyphenylene Sulphide 9 2 Domestic water supply BMQE Operating conditions Controller installation Flow: Max. 39 US gpm (8.9 m3/h) Head: Max. 300 ft (91.4 m) All BMQE pumps can be connected to BMQE controllers. Each BMQE pump must be connected to its own BMQE controller. Liquid temperature: Max. 95°F (35°C) Operating pressure: Max. 347 psi (23 bar) Inlet pressure: Min. 8 psi (0.55 bar) Sound-pressure level: The sound pressure level of the BMQE is lower than 74 db[A] at a distance of 3 ft (1 m). Installation The sound pressure level of the BMQE is <74 db[A] at a distance of 3 ft (1 m). It is recommended by Grundfos that the pump be installed with sound and vibration dampening equipment (flexible piping adapters and anti-vibration mounting — not sold by Grundfos). Like most mechanical equipment, this system can create noises and vibrations. Grundfos recommends that the BMQE pump should not be mounted in or adjacent to living quarters. Positioning the pump TM04 9411 4110 The GRUNDFOS BMQE pump is supplied with a built-in non-return valve. An arrow on the BMQE sleeve shows the direction of liquid flow through the pump (fig. 7). The BMQE is suitable for both vertical and horizontal installation; however, the discharge port should never fall below the horizontal plane. See fig. 8. The BMQE must be installed with the air relief vent in the 12 o’clock position when installed horizontally and when installed in the vertical position, the air vent must be at the top of the unit. Fig. 7 Power supply entry Pressure sensor entry Submersible drop cable entry Fig. 9 BMQE controller entry ports Connection of motor The BMQE incorporates a starter device and can therefore be connected directly to the main power supply. The BMQE incorporates thermal overload protection and requires no additional motor protection. Cable installation In situations where multiple BMQE power cables are run parallel in wiring trays or conduit and less than 12 inches apart, the possibility for undesired communication between units exists. When this occurs, intermittent or continuous NO CONTACT is typically seen. Other unexpected errors may also be seen. The chart shows single-phase 60 Hz maximum cable length motor service to entrance. The maximum cable length with one BMQE controller is 650 ft (198.1 m); the maximum wire size is 10 AWG. Maximum cable length (one controller) Motor rating Arrow showing direction of liquid flow through pump Copper wire size (AWG) 14 Volts 12 10 Hp Maximum cable length [ft (m)] 115 TM04 1375 230 Fig. 8 10 Installation positions TM01 7841 1511 Location of installation 0.50 100 (30.5) 160 (48.8) 250 (76.2) 0.50 400 (121.9) 650 (198.1) 650 (198.1) 0.75 300 (91.4) 480 (146.3) 650 (198.1) 1.0 250 (76.2) 400 (121.9) 630 (192) 2 BMQE pumps connected in parallel Pressure sensor installation When connecting BMQE pumps in parallel (fig. 10) a separate BMQE controller must be used on each BMQE pump. Set the pressure on one BMQE 10 psi lower than the other. For BMQE pumps connected in parallel, mount one above the other; it is recommended to connect the pipes as shown in fig. 10. This layout ensures that the BMQE pumps are filled with water before starting. The BMQE controller keeps the pressure constant in the place where the pressure sensor is positioned. The maximum shielded cable length for the sensor must not exceed 1600 ft (487.7 m). BMQE Domestic water supply Generator operation Power may be supplied to BMQE pumps by an adequately sized generator. The generator must be sized 50 % above the pumps P1 (input power) values. Minimum generator size [watts] Recommended generator output [watts] 0.33 to 0.50 A 1100 1500 0.50 to 0.75 B 1700 2300 1.0 to 1.5 B 2000 3500 TM04 9413 4110 Motor Hp Fig. 10 Booster unit with two BMQE pumps connected in parallel, mounted one above the other Additional considerations when connecting in parallel: • All BMQE modules are supplied with a non-return valve. • BMQE modules connected in parallel may also be installed vertically. • As venting problems may arise in such installations, it is advisable to install suitable air vent devices. • The BMQE should be positioned with the discharge and air vent at the top when installed vertically. • When the maximum flow for BMQE pumps in parallel will exceed 35 gpm, a 4-gallon or two 2-gallon diaphragm tank(s) should be used. 11 2 Domestic water supply BMQE Quick selection guide Example: • The maximum demand is 15 gpm (3.4 m3/h). • The pressure required is 70 psi (4.8 bar) system pressure at the taps in the building. • The normal minimum inlet pressure (e.g. city pressure) is 20 psi (1.4 bar) • The additional boost required is 50 psi (3.5 bar) at 15 gpm (3.4 m3/h). • Select a 15 BMQE 05A-110. Additional (boost) pressure required [psi] Flow required [gpm] 5 10 15 20 25 30 35 39 90 80 15 BMQE 07B-180 70 22 BMQE 10C-190 60 50 40 22 BMQE 05B-120 30 BMQE 10C-130 15 BMQE 05A-110 30 20 22 BMQE 05A-80 30 BMQE 05B-90 10 Curve charts and technical data How to read the curve charts P [psi] H [ft] H [m] 15 BMQE 60 Hz 140 100 300 Pump type and frequency. 120 80 250 07B -180 (5-s tage) 100 200 60 80 QH curve for the individual pump. 150 05A -110 (3-s tage) 60 40 100 40 20 The efficiency curve shows the efficiency of the pump. The efficiency curve is an average curve of all the pump types shown in the chart. 20 0 50 0 0 0 2 0. 0 P2 [kW] 4 0. 5 6 1. 0 8 1. 5 10 2. 0 12 2. 5 14 3. 0 16 3. 5 18 4. 0 Q [US GPM] The power curves indicate pump input power per stage. 4. 5 Q [m³/h] P2 [hp] Et a [%] 0. 3 60 P2 0. 2 40 0. 1 0. 1 20 Et a 0. 0 0. 0 0 0 12 2 4 6 8 10 12 14 16 18 Q [US GPM] TM04 4551 1609 0. 2 2 Domestic water supply P [psi] H [ft] BMQE 15 BMQE 60 Hz H [m] 15 BMQE 60 Hz 140 100 300 120 80 250 07B -180 (5-s tage) 100 200 60 80 150 05A -110 (3-s tage) 60 40 100 40 20 20 0 50 0 0 0 2 0. 0 P2 [kW] 4 0. 5 6 1. 0 8 1. 5 10 2. 0 12 2. 5 14 3. 0 16 3. 5 18 4. 0 Q [US GPM] 4. 5 Q [m³/h] P2 [hp] Et a [%] 0. 3 60 0. 2 P2 0. 2 40 0. 1 0. 1 20 0. 0 0. 0 0 0 2 4 6 8 10 12 14 16 18 Q [US GPM] TM05 0772 1511 Et a 13 2 Domestic water supply BMQE 22 BMQE 60 Hz P [psi] H [ft] H [m] 22 BMQE 60 Hz 140 100 300 120 80 250 100 200 10C -190 (5-s tage) 60 80 150 60 40 05B -120 (3stage) 100 40 05A -80 (2-stage) 20 20 0 50 0 0 0 5 0 P2 [kW] 1 10 2 15 3 20 4 25 5 30 6 Q [US GPM] 7 Q [m³/h] P2 [hp] Et a [%] 0. 6 60 0 0. 4 40 P2 0 0 0. 0 0 0 14 20 Et a 5 10 15 20 25 30 Q [US GPM] TM05 0773 1511 0. 2 2 Domestic water supply P [psi] H [ft] 30 BMQE 60 Hz 220 BMQE 30 BMQE 60 Hz H [m] 70 90 200 60 80 180 70 160 60 140 50 10C -130 (3-s tage) 40 120 50 100 05B -90 (2-stage) 30 40 80 30 20 60 20 40 10 10 0 20 0 0 0 5 0 P2 [kW] 1 10 2 15 3 20 4 25 5 30 6 35 7 8 Q [US GPM] 9 Q [m³/h] P2 [hp] Et a [%] 0. 6 60 0 P2 0. 4 40 0 0 20 Et a 0. 0 0 0 5 10 15 20 25 30 35 Q [US GPM] TM05 0774 1511 0. 2 15 2 Domestic water supply BMQE Weights and electrical data Product number Max. motor output [hp] Rated voltage [V] Rated current [A] Locked rotor current [A] Shipping weight [lb (kg)] 15 BMQE 05A-110 91128524 0.845 110-115 9.2 11.1 26 (11.8) 22 BMQE 05A-80 91128527 0.845 110-115 7.8 11.1 26 (11.8) 15 BMQE 05A-110 91128525 0.845 200-240 4.6 5.0 26 (11.8) 15 BMQE 07B-180 91128526 1.408 200-240 7.1 8.0 29 (13.2) 22 BMQE 05A-80 91128528 0.845 200-240 3.9 5.0 26 (11.8) 22 BMQE 05B-120 91128529 1.408 200-240 5.6 8.0 29 (13.2) Model 22 BMQE 10C-190 91128530 2.320 200-240 9.9 11.1 31 (14.1) 30 BMQE 05B-90 91128531 1.408 200-240 6.0 8.0 31 (14.1) 30 BMQE 10C-130 91128533 2.320 200-240 9.5 11.1 31 (14.1) Shipping volume [ft3 (m3)] 0.9 (0.025) Dimensional sketch, BMQE pump B F Air vent screw TM01 7323 1511 E D A Cable entry C Dimensions A B [in (mm)] C [in (mm)] D [in (mm)] E [in (mm)] F 1.0" NPT 43.3 (1100) 0.8 (20.5) Ø 4.6 (116) Ø 3.5 (88.9) 1.25" NPT Dimensional sketch, BMQE controller B C TM05 0720 1511 A BMQE Dimensions [in (mm)] 16 A B C 7.68 (195) 9.13 (232) 4.49 (114) 2 Domestic water supply Main power supply to pump 1 x 200-240 V –10 % / +6 %, 60 Hz 1 x 110-115 V –10 % / +6 %, 60 Hz Starting Soft starting. The motor starting current is equal to the highest value stated on the BMQE nameplate. Stopping Soft stopping when stopped by the BMQE controller Run-up time Maximum: 2 seconds. No limitation to the number of starts/stops per hour. Motor protection BMQE Technical data, BMQE pump Built into the pump. Protection against: • Dry running • Over voltage and under voltage 230 V cuts out at < 150 V and > 280 V 115 V cuts out at < 75 V and > 150 V • Overload • Over temperature The sound pressure level is < 74 db[A] at a distance of 3 feet (1 meter). Sound pressure level It is recommended by Grundfos that the pump be installed with sound and vibration dampening equipment such as flexible piping adapters and anti-vibration mounting.* The pump should not be mounted in or adjacent to living quarters. The pump can also be wrapped with sound proofing insulation to reduce noise.* Reset function BMQE pumps can be reset via BMQE controller Power factor PF = 1. Operation via generator It is recommended that the generator output is equal to the motor input power P1 [kW] plus 50 %; min. P1 +10 %, however. Pipe connection 1.25” NPT inlet / 1” NPT discharge Strainer Holes of the strainer: ø0.09” (2.3 mm) Approvals UL Listed, CE (SQE Pump with MSE 3 motor only) Weight 31 lbs. (14.1 kg) Voltage 1 x 100-240 V –10 % / +6 %, 60 Hz * Not sold by Grundfos. Technical data, BMQE controller Voltage 1 x 100-240 V -10 % / +6 %, 60 Hz Power consumption 5W Current consumption Maximum 130 mA Motor cable • 2-wire w/ground, 12 AWG Teflon • B: Black (Line, Neutral) • G: Green (Ground) Enclosure class NEMA 3R (IP 55) Ambient temperature In operation: -22 to +122 °F (-30 to +50 °C). During storage: -22 to +140 °F (-30 to +60 °C) Relative air humidity 95 % Pump cable Maximum length between BMQE controller and pump: 650 ft (198 m) Back-up fuse Maximum: 16 A Load Max. 100 mA Approvals UL Listed, CE 17 2 Domestic water supply BMQE BMQE constant pressure kit Description BMQE controller and pressure sensor Rating Setting range 40 to 100 psi (2.8 to 6.9 bar) TM05 0732 / TM05 0733 BMQE Accessories, BMQE Product number 91128636 Fig. 11 BMQE constant pressure kit BMQE controller BMQE controller Rating Setting range 40 to 100 psi (2.8 to 6.9 bar) Product number 91121987 BMQE TM05 0732 1511 Description Sensor Description Pressure sensor for BMQE controller Rating 0 to 120 psi (0 to 8.3 bar), 1/2” NPT Product number 96437852 Fig. 12 BMQE controller Description Weight [lbs (kg)] Product number Diaphragm tank, 2 gal. 5 (2.3) 91121984 TM05 0733 1511 Diaphragm tank Fig. 13 Pressure sensor for BMQE controller Dimensions G connection D [in (mm)] H [in (mm)] 3/4” NPT 8 (203) 12.63 (321) Specifications Duty range Pre-charge pressure: 40 psi (2.8 bar) TM05 0734 1511 Max. operating pressure: 150 psi (10.3 bar) Max. liquid temperature: 200 °F (93 °C) Materials Liner: Polypropylene Connection: Lead-free brass Tank: Stainless steel, AISI 304 18 Fig. 14 Diaphragm tank 3 Domestic water supply MQ 3. MQ Product introduction Outlet connnection can be angled up to 5° to fit existing pipework. The Grundfos MQ is a compact pump and pressure boosting unit, purpose-designed for domestic water supply and other applications where a compact and reliable, easy-to-install pump is advantageous. The MQ is a self-priming multistage centrifugal pump; it self-primes from a well depth of down to 26 ft (8 m) within 5 minutes. The MQ is a complete, all-in-one unit, incorporating pump, motor, diaphragm tank, pressure and flow sensor, controller and check valve. Simple operation The MQ features a user-friendly control panel with ON/OFF button and indicator lights for indication of the operational state of the pump. Compact design Compact, horizontal design fits even where space is limited (outdoor applications require the use of the Protection Cover, sold separately); no space around the pump is required. Self-priming TM01 9873 As it is self-priming, the MQ is able to pump water from a level below the pump. Provided it is filled with water, the pump is able to lift water from a depth of 26 ft (8 m) in less than 5 minutes. This facilitates installation and start-up of the pump and provides more reliable water supply in installations where there is a risk of dry running and leakages in suction hose or pipes. Fig. 15 Grundfos MQ Applications Built-in protective functions Built-in protective functions; if exposed to dry running, excessive temperature, or any overload condition the pump will stop automatically, thus preventing a motor burnout. MQ is suitable for pressure boosting of potable water and rain water for: • water pressure boosting (max. inlet pressure 40 psi (2.8 bar) • water supply from wells (max. suction lift: 26 ft (8 m). Examples of ideal applications for MQ are: • private homes • farms • market gardens and other large gardens. Automatic reset Pumped liquids The built-in pressure tank reduces the number of starts and stops in case of leakages in the pipe system, causing less wear on the pump. The MQ is suitable for pumping potable water, rain water, or other clean, thin, non-aggressive liquids not containing solid particles or fibers. Features and benefits Complete system The MQ is a compact, "plug and pump" or all-in-one solution; there is no need for a separate pressure tank, pressure switch, electrical connections, fittings, or any other separate items. No maintenance of the pump is required. Two versions are available to choose from. Installation In case of dry running or a similar alarm, the pump will stop. Restarting will be attempted every 30 minutes for a period of 24 hours. The reset function can be deactivated. Low noise level Superior hydraulics and internal cooling combined result in very quiet operation, which makes it suitable for many applications. Pressure tank How the MQ functions The MQ pump has a small built-in pressure tank, sufficient to ensure that water is readily available from the tap. When water is required, the pump automatically starts. A non-return valve prevents backflow. The controller ensures that the pump starts automatically when water is consumed and stops automatically when the consumption ceases. In addition, the controller protects the pump in case of faults. Installation of the MQ is simple and can be done in a matter of minutes, which means greatly reduced installation costs. 19 3 Domestic water supply MQ Identification Type key, MQ Example Pump range Rated flow [m3/h] Max. head [m] Code for pump version A: standard Code for pipework connection B: External thread Code for materials A: Standard Code for shaft seal B: Bellow seal, rubber V: Ceramic B: Carbon, resin-impregnated P: NBR (nitrile rubber) 20 MQ 3 - 35 A -B -A - BVBP 3 Domestic water supply MQ Product overview Performance range, MQ 60 Hz H P [ft] [psi] 140 120 100 MQ 3 60 Hz 70 ISO 9906 Annex A -45 60 40 45 40 -35 50 35 30 40 25 80 60 50 30 20 20 15 20 10 0 0 10 5 0 2 0.0 0.5 4 6 1.0 8 1.5 10 2.0 12 2.5 14 3.0 16 3.5 Q [US GPM] 4.0 Q [m³/h] 0 TM04 4141 0909 160 H [m] Product range, MQ Range MQ 3-35 Maximum flow rate [gpm (m3h)] Maximum pressure [psi (bar)] Maximum system pressure [psi (bar)] Maximum inlet pressure [psi (bar)] Maximum suction lift [ft (m)] MQ 3-45 19 (4.3) 49 (3.4) 63 (4.3) 109 (7.5) 40 (2.7) 26 (8) Minimum ambient temperature [°F (°C)] 32 (0) Maximum ambient temperature [°F (°C)] 113 (45) Minimum liquid temperature [°F (°C)] 32 (0) Maximum liquid temperature [°F (°C)] 95 (35) Net weight [lbs (kg)] Sound pressure level [dB(A)] Tank volume [oz (ml)] Air pressure in tank [psi (bar)] Connections Priming and drain plugs 29 (13.2) < 60 13.5 (399) 22 to 25 (1.5 to 1.7) 1" NPT 3/8" GAS 21 3 Domestic water supply MQ Construction Components, MQ MQ control panel 1 3 1 2 4 9 5 8 6 3 6 4 5 TM05 0691 1411 7 Fig. 17 MQ control panel Pos. Description 1 Fig. 16 MQ pump components Power indicator light 2 Pos. 22 Description 1 Protective cover (accessory) 2 Discharge port 3 Suction port 4 Drain plug 5 Baseplate 6 Priming plug 7 Shaft access port plug 8 Pressure tank 9 Control panel TM05 0769 1511 2 Indicates the pump is ready for operation (green). Indicates the pump is on standby (red). Pump is started and stopped by pressing On/Off button. 3 On/Off button 4 Pump ON (green) Indicates pump is running. 5 Auto reset Indicates auto reset function is active. After an alarm, restarting will be attempted every 30 minutes, for a period of 24 hours. 6 Alarm (red) Indicates pump is in alarm state. Manual resetting is possible by pressing On/Off button. 3 Domestic water supply Pos. Components MQ Material specification, MQ Material 2 Support flange PP + 30 % glass fiber 4 Chamber PPO + 20 % glass fiber 7 Drain and priming plug PPO + 20 % glass fiber 10 Self-priming valve PP + 30 % glass fiber 14 Self-priming part Pos. Pump sleeve Stainless steel, DIN W.-Nr. 1.4301, AISI 304 42 Tank cover PP + 30 % glass fiber HB (f1) Material 101 Suction port PPO + 20 % glass fiber 103 104 Shaft seal: Stationary and rotating part Carbon/ceramics/NBR rubber 149 Insulation disc PA 5VA (Polyammide) Shaft Stainless steel, DIN W.-Nr 1.4005, AISI 416 Motor sleeve Stainless steel, DIN W.-Nr 1.4301, AISI 304 PPO + 20 % glass fiber 16 Components 150 164 174a Terminal box cover PP + 30 % glass fiber 5VA (f1) Pressure switch POM + 25 % glass fiber / SIL Rubber (Silicone Rubber) Pressure switch membrane SIL Rubber - Silicone Rubber. 49 Impeller PPO + 20 % glass fiber-PTFE 51 Motor cover PP + 30 % glass fiber HB (f1) 65 Non-return valve POM + 25 % glass fiber 180 Motor body PP + 30 % glass fiber 5VA (f1) 92 Clamp Stainless steel, DIN W.-Nr 1.4301, AISI 304 184 Flow sensor POM + 25 % glass fiber 100a Discharge port PPO + 20 % glass fiber O-rings NBR-rubber POM: Polyoximetylen NR-rubber: Natural Rubber PPO: Polyphenylene Oxides PP: Polypropylene NBR-rubber: Nitrile-Butadiene Rubber 164 ×ÖÖ` 184 174a 65 42 Úß ×Ü Ú Ø ×Ö× ×Ú Ý 180 150 92 103 104 TM01 9733 1411 51 10 Fig. 18 MQ exploded view 23 3 Domestic water supply MQ Operating conditions System pressure: Max. 109 psi (7.5 bar) Inlet pressure: Max. 40 psi (2.8 bar) Suction lift: Max. 26 ft (8 m) Liquid temperature: 32°F to +95°F (0°C to +35°C) Ambient temperature: 32°F to +113°F (0°C to +45°C) Installation Location The pump is suitable for indoor and outdoor installation. It is resistant to sunlight. For outdoor installation, the pump must be fitted with a protective cover (accessory). Should the unlikely event of an internal leakage occur, pumped liquid will be drained out from the base and/or end cover instead of damaging the pump. Install the pump in such a way that no undesirable collateral damage can arise. Positioning the pump Mount the pump on the base plate with horizontal suction port and vertical discharge port. The pump must be installed horizontally. The maximum permissible inclination angle is +/- 18 °. To prevent movement and vibrations, the pump and base plate can be secured to a solid foundation by means of the bolt holes in the base plate. Selection of product MQ is available in two sizes and two voltages. Model MQ 3-35 MQ 3-45 24 Voltage [V] Product number 115 96860172 230 96860201 115 96860195 230 96860207 3 Domestic water supply MQ Curve charts and technical data MQ 3-35 60 Hz, suction lift performance curve H [ft] P [psi] 110 48 MQ 3-35 34 46 60 Hz 32 100 H [m] 44 30 42 90 40 28 38 26 36 80 24 34 32 70 60 22 30 28 20 26 18 24 50 16 22 20 40 14 18 12 16 10 14 12 26.2 ft 10 20 23 ft 8 19.7 ft 13.1 ft 6.6 ft 8 6 6 10 4 0 ft 4 2 2 0 0 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 Q [US GPM] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 Q [m³/h] TM05 2056 4311 30 Provided it is filled with water, the pump is able to lift water from a depth of 26 ft (8 m) in less than 5 minutes. Note: Use with a foot valve in suction lift applications. 25 3 Domestic water supply H [ft] 140 130 120 110 100 90 80 70 60 50 40 30 20 10 0 P [psi] H [m] 64 62 60 58 56 54 52 50 48 46 44 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 8 6 4 2 0 MQ 3-45 44 60 Hz 42 40 38 36 34 32 30 28 26 24 22 20 18 16 14 12 10 26.2 ft 23 ft 19.7 ft 13.1 ft 8 6.6 ft 6 0 ft 2 0 0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Q [US GPM] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Provided it is filled with water, the pump is able to lift water from a depth of 26 ft (8 m) in less than 5 minutes. Note: Use with a foot valve in suction lift applications. 26 4 4.0 Q [m³/h] TM05 2057 4311 MQ MQ 3-45 60 Hz, suction lift performance curve 3 Domestic water supply MQ Dimensional sketch - MQ D E H A TM01 9799 F B G C Dimensions [in (mm)] A B C D E F G H 9.45 (240) 2 x 3/8 (2 x 9.6) 22.44 (570) 7.56 (192) 12.60 (320) 4.49 (114) 8.58 (218) 12.74 (324) Weights and electrical data -10/+6 % voltage tolerance 7.5 ft. power cord with plug Part Number Phase, Volts MQ 3-35 96860172 MQ 3-45 Model Amps P2 Net wt. [lb (kg)] Run Start W Hp 1X110-120V 8 29 585 0.75 30.1 (13.7) 96860195 1X110-120V 10 29 725 1 30.2 (13.7) MQ 3-35 96860201 1X220-240V 4 15 565 0.75 30.1 (13.7) MQ 3-45 96860207 1X220-240V 4.8 15 716 1 30.2 (13.7) Approvals Liquid Pump Drinking Water NSF / ANSI 61 NSF / ANSI 372 Low Lead Content 27 3 Domestic water supply MQ protective cover Protects keypad and electronics in outdoor applications. Required for outdoor applications where MQ is exposed to the elements. Two Velcro tabs are included to help adhere back end of cover to pump. Description MQ protective cover 28 Material Product number Polypropylene with Velcro tabs 96693071 MQ protective cover TM05 0787 1511 MQ Accessories, MQ 4 Domestic water supply Product introduction JP Jet Pumps 4. JP Jet Pumps • technopolymer impeller • convenient priming plug for ease of priming and air elimination • ceramic-carbon bellows mechanical seal ensures trouble-free operation • high quality pressure switch. The Grundfos JP line of self-priming centrifugal jet pumps is designed for shallow well, deep well, and convertible shallow well pump applications. JP pumps provide excellent suction capacity. TM05 1948 4011 Deep well - cast iron JP05D-CI, JP07D-CI, JP15D-CI, JP20D-CI Fig. 19 Grundfos JP line (from left to right: JP shallow well; JP deep well; and JP convertible shallow well) Applications Grundfos JP pumps are particularly suitable for: • domestic water supply systems • light agricultural • industrial water transfer • home and market gardens. Features and benefits Shallow well - cast iron JP05S-CI, JP07S-CI, JP10S-CI, JP30S-CI Single-stage, shallow well self-priming centrifugal pumps. Features: • Rugged cast iron construction • end suction, top discharge arrangement • technopolymer impeller • built-in ejector complete with clean-out port to clear blockages from nozzle • convenient priming plug for ease of priming and air elimination • ceramic-carbon bellows mechanical seal ensures trouble-free operation • high quality pressure switch. Shallow well convertible - cast iron JP15S-CI, JP20S-CI Single stage, convertible, self-priming centrifugal pumps. Features: • Rugged cast iron construction • end suction, top discharge arrangement • detachable ejector assembly for deep well applications Single-stage, deep well, self-priming centrifugal pumps. Features: • Rugged cast iron construction • end suction, top discharge arrangement • technopolymer impeller • separate deep well port for connection to Deep Well Ejector Kit • convenient priming plug for ease of priming and air elimination • ceramic-carbon bellows mechanical seal ensures trouble-free operation • high quality pressure switch. Shallow well - stainless steel JP05S-SS, JP07S-SS, JP10S-SS Single-stage, shallow well self-priming centrifugal pumps constructed of stainless steel. Features: • Corrosion-resistant stainless steel • end suction, top discharge arrangement • technopolymer impeller • built-in ejector complete with clean-out port to clear blockages from nozzle • ceramic-carbon bellows mechanical seal ensures trouble-free operation • high quality pressure switch. Motors All Grundfos JP motors are Totally Enclosed and Fan-Cooled (TEFC) for quiet operation and superior protection in harsh environments. Features: • Stainless steel motor shaft offers excellent corrosion resistance • Double, oversized grease ball bearings are maintenance-free; sealed for life • Built-in thermal overload protection • Capacitor-run, with no switches to fail • Drive end motor bearing protected by durable lip seal • Insulation class F • Motor protection IP44 • Terminal box protection IP55. 29 4 Domestic water supply JP Jet Pumps Identification Type key Example Jet pump Horsepower 03: 1/3 Hp 05: 1/2 Hp 07: 3/4 Hp 10: 1 Hp 15: 1-1/2 Hp 20 2 Hp 30: 3 Hp Well type S: Shallow Well D: Deep Well Material CI: Cast Iron SS: Stainless Steel EC: Engineered Composite 30 JP 05 S CI 4 Domestic water supply JP Jet Pumps Product overview Conversion chart Old JPF Shallow Well Cast Iron Jet Pumps Type Volts Pressure switch setting [psi] New Shallow Well Cast Iron Jet Pumps Material number Hp Ph Volts Pressure switch setting [psi] JP05S-CI (JP4-47ASA) 1/2 1 115/230 30-50 JP07S-CI (JP4-54ASA) 3/4 1 115/230 30-50 JP10S-CI (JP4-61ASA) 1 1 115/230 30-50 97855085 96430416 JP15S-CI (JP5-61ASA) 1-1/2 1 230 40-60 97855091 96457277 JP20S-CI (JP8-62ASA) 2 1 230 40-60 97855094 JP30S-CI (JP12-51ASA) 3 1 230 40-60 97855095 Hp Ph JPF3 1/2 1 115 30-50 96430412 JPF3 1/2 1 230 30-50 96430413 JPF4 3/4 1 115 30-50 96430414 JPF4 3/4 1 230 30-50 96430415 JPF5 JPF7 1-1/2 2 1 1 230 230 50-70 50-80 Type Old JPF Shallow Well Stainless Steel Jet Pumps Type Volts Pressure switch setting [psi] Ph JPS2 1/2 1 115 30-50 96430421 JPS2 1/2 1 230 30-50 96430422 JPS4 1 1 115 30-50 96430423 JPS4 1 1 230 30-50 96430424 Ph Volts Pressure switch setting [psi] Ph Volts Pressure switch setting [psi] Material number JP05S-SS (JP4-47ASI) 1/2 1 115/230 30-50 97855075 JP07S-SS (JP4-54ASI) 3/4 1 115/230 30-50 97855083 JP10S-SS (JP4-61ASI) 1 1 115/230 30-50 97855088 New Deep Well Cast Iron Jet Pumps* Material number JDF2 1/2 1 115 30-50 96430417 JDF2 1/2 1 230 30-50 96430418 JDF4 3/4 1 115 30-50 96430419 JDF4 3/4 1 230 30-50 96430420 *Ejector not included 97855081 Hp Type Old JPF Deep Well Cast Iron Jet Pumps* Hp 97855073 New Shallow Well Stainless Steel Jet Pumps Material number Hp Type Material number Hp Ph Volts Pressure switch setting [psi] Material number JP05D-CI (JP4-47DSA) 1/2 1 115/230 30-50 97855072 JP07D-CI (JP4-54DSA) 3/4 1 115/230 30-50 97855080 JP15D-CI (JP5-61DSA) 1-1/2 1 230 40-60 97855090 JP20D-CI (JP8-62DSA) 2 1 230 40-60 97855093 Type *Ejector not included 31 4 Domestic water supply JP Jet Pumps Performance range H [m] H [ft] JP 210 60 p [psi] 90 60 Hz 200 85 190 80 55 180 75 170 50 45 40 160 70 150 65 140 60 130 55 JP10 120 50 35 110 45 30 100 40 90 25 35 80 JP05 JP07 JP15 JP20 JP30 70 30 20 60 15 25 50 20 40 5 15 30 10 20 5 10 0 0 0 0 5 10 15 20 25 30 35 40 45 50 55 60 Q [US GPM] 0 32 2 4 6 8 10 12 Q [m³/h] TM05 1230 4511 10 4 Domestic water supply JP Jet Pumps Product range Shallow well Shallow well cast iron Shallow well stainless steel Model JP05S-CI 3 Max. flow [gpm (m h)] Max. pump head [ft (m)] JP07S-CI JP10S-CI JP30S-CI JP05S-SS JP07S-SS JP10S-SS 21 (4.7) 20 (4.5) 20 (4.5) 23 (5.2) 34 (7.7) 52 (11.8) 21 (4.7) 20 (4.5) 20 (4.5) 170 (51.2) 200 (61.0) 210 (64.0) 210 (64.0) 170 (51.2) 145 (44.2) 170 (51.2) 200 (61.0) 1/2 3/4 1 2 3 1/2 116 (8) Fluid temp range [°F (°C)] 116 (8) 1 1/2 +32 to +95 (0 to +35) Max. lift [ft suction lift at sea level] Max. ambient temp [°F (°C)] Factory pressure switch setting [psi (bars)] JP20S-CI 145 (44.2) Max. working pressure [psi (bars)] Motor power [hp] JP15S-CI 30/50 (2.1/3.5) Storage temp range [°F (°C)] 30/50 (2.1/3.5) 3/4 25 25 +104 (+40) +104 (+40) 30/50 (2.1/3.5) 40/60 (2.8/4.1) 1 +32 to +95 (0 to +35) 40/60 (2.8/4.1) 40/60 (2.8/4.1) 30/50 (2.1/3.5) 30/50 (2.1/3.5) 30/50 (2.1/3.5) +14 to +104 (-10 to +40) +14 to +104 (-10 to +40) 95% 95% 20 20 Relative humidity Max. starts per hour Deep well Deep well cast iron Model JP05D-CI 3 Max. flow [gpm (m h)] Max. pump head [ft (m)] JP07D-CI 18 (4.0) 18 (4.0) 21 (4.7) 32 (7.2) 170 (51.2) 195 (59.4) 200 (61.0) 1/2 3/4 1 1/2 2 116 (8) Fluid temp range [°F (°C)] Max. lift [ft suction lift at sea level] +32 to +95 (0 to +35) 50 Max. ambient temp [°F (°C)] Factory pressure switch setting [psi (bars)] Storage temp range [°F (°C)] Relative humidity Max. starts per hour JP20D-CI 145 (44.2) Max. working pressure [psi (bars)] Motor power [hp] JP15D-CI 70 90 90 40/60 (2.8/4.1) 40/60 (2.8/4.1) +104 (+40) 30/50 (2.1/3.5) 30/50 (2.1/3.5) +14 to +104 (-10 to +40) 95% 20 33 4 Domestic water supply JP Jet Pumps Construction Materials of construction Shallow well - cast iron, stainless steel 1 Descriptions: in contact with liquid 7 TM05 2216 4611 16 160 Pos. 28 4 3 Cast iron models Materials Stainless steel models Cast Iron 200 UNI ISO 185 All Stainless Steel AISI 304 3 Support Cast Iron 200 Uni ISO 185 JP15, JP20, JP30 3 Support Aluminum + AISI304 JP05, JP07, JP10 4 Impeller Technopolymera All Stainless Steel AISI 416 All 7 Shaft with Rotor Stainless Steel AISI 303 16 Mechanical Seal Carbon / ceramic All 28 OR Gasket NBR Rubber All 160 Nozzle-Venruri Diffuser Assembly Technopolymera All 1 Pump Body All All All All All All All Deep well - cast iron 1 6 4 28 3 8 TM05 2215 4611 2 9 16 Pos. 1 3 4 6 34 Descriptions: in contact with liquid Pump Body Support Impeller Diffuser 7 Materials 7 Shaft with Rotor 16 28 Mechanical Seal OR Gasket Cast Iron 200 UNI ISO 185 Cast Iron 200 UNI ISO 185 Technopolymer Technopolymer Stainless Steel ANSI 416 Stainless Steel ANSI 303 Carbon/Ceramic NBR Rubber 2 8 9 Ejector Body Venturi Tube Nozzle Cast Iron 200 UNI ISO 185 Technopolymer Brass Cast iron models All All All All JP05 & JP07 JP15 & JP20 All All E20, E25, E30 E20, E25, E30 E20, E25, E30 4 Domestic water supply Max. operating pressure: Installation 116 psi (8 bar) Liquid temp range: JP Jet Pumps Operating conditions Pump location +32 °F to +95 °F (0 °C to +35 °C) Max. relative humidity of air 95% Storage temp range: +14 °F to +104 °F (-10 °C to 40 °C) Selection Pumped liquids JP pumps are suitable for pumping clean, non-viscous, non-aggressive, non-explosive liquids, free of solid particles or fibers. The pump must be located in a well-ventilated place, protected from unfavorable weather conditions and with an environmental temperature not exceeding 104 °F (40 °C). It is always good practice to place the pump as close as possible to the liquid to be pumped. Pump position Allowable positions Selection of pumps Pump type Hp Ph Volts [V] Pressure switch setting [psi] Product number JP05S-CI 1/2 1 115/230 30-50 97855073 JP07S-CI 3/4 1 115/230 30-50 97855081 JP10S-CI 1 1 115/230 30-50 97855085 JP15S-CI 1-1/2 1 230 40-60 97855091 JP20S-CI 2 1 230 40-60 97855094 JP30S-CI 3 1 230 40-60 97855095 TM05 1232 2411 Shallow well - cast iron Fig. 20 Pump must be installed in horizontal position only The pump must be installed only in horizontal position. To prevent movement and vibrations, anchor the pump firmly to a horizontal surface. Shallow well - stainless steel Pump type Hp Ph Volts [V] Pressure switch setting [psi] Product number JP05S-SS 1/2 1 115/230 30-50 97855075 JP07S-SS 3/4 1 115/230 30-50 97855083 JP10S-SS 1 1 115/230 30-50 97855088 Deep well - cast iron* Pump type Hp Ph Volts [V] Pressure switch setting [psi] Product number JP05D-CI 1/2 1 115/230 30-50 97855072 JP07D-CI 3/4 1 115/230 30-50 97855080 JP015D-CI 1-1/2 1 230V 40-60 97855090 JP020D-CI 2 1 230V 40-60 97855093 * Ejector not included Deep well ejectors Type Product number E20 NPT 96654382 E25 NPT 96654383 E30 NPT 96654384 35 4 Domestic water supply JP Jet Pumps Curve charts and technical data Performance curves Models JP05S-CI, JP05S-SS 45 H [ft] 150 QH 140 40 35 30 25 20 15 JP05 p [psi] 65 60 Hz 60 130 55 120 50 110 45 100 90 40 80 35 70 30 60 25 50 20 40 10 5 0 15 30 20 10 10 5 0 0 0 2 4 6 0.0 0.5 1.0 1.5 8 10 2.0 12 2.5 14 3.0 16 3.5 18 4.0 20 22 24 Q [US GPM] TM05 1137 5111 H [m] 4.5 Q [m³/h] Models JP07S-CI, JP07S-SS H [m] H [ft] p [psi] JP07 180 50 160 70 140 60 40 120 30 80 60 Hz QH 50 100 40 80 10 0 36 30 60 20 40 20 10 0 0 0 2 4 6 0.0 0.5 1.0 1.5 8 2.0 10 12 2.5 14 3.0 16 3.5 18 4.0 20 22 24 Q [US GPM] 4.5 Q [m³/h] TM05 1139 5111 20 4 Domestic water supply H [m] H [ft] 60 200 p [psi] JP10 QH 60 Hz 180 50 80 160 70 140 60 40 120 30 JP Jet Pumps Models JP10S-CI, JP10S-SS 50 100 40 80 10 30 60 20 40 10 20 0 0 0 0 2 4 6 8 0.0 0.5 1.0 1.5 10 2.0 12 2.5 14 3.0 16 3.5 18 4.0 20 22 24 Q [US GPM] TM05 1141 5111 20 4.5 Q [m³/h] Model JP15S-CI H [m] H [ft] p [psi] JP15 220 60 50 40 30 QH 60 Hz 200 90 180 80 160 70 140 60 120 50 100 40 80 10 30 60 20 40 10 20 0 0 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 Q [US GPM] 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0 4.5 Q [m³/h] TM05 1147 5111 20 37 4 Domestic water supply JP Jet Pumps Model JP20S-CI H [m] H [ft] p [psi] 220 60 50 40 30 JP20 QH 60 Hz 200 90 180 80 160 70 140 60 120 50 100 40 80 10 30 60 20 40 10 20 0 0 0 0 4 0 1 8 12 2 16 3 20 4 24 5 28 6 32 36 40 Q [US GPM] 7 TM05 1148 5111 20 Q [m³/h] Model JP30S-CI H [m] H [ft] p [psi] JP30 180 50 QH 160 70 140 60 40 120 30 80 60 Hz 50 100 40 80 10 30 60 20 40 10 20 0 38 0 0 0 4 0 1 8 2 12 16 20 24 28 32 36 40 44 48 52 56 Q [US GPM] 3 4 5 6 7 8 9 10 Q [m³/h] TM05 1150 5111 20 4 Domestic water supply Pump type JP05S JP07S JP10S JP15S JP20S JP30S Part number cast iron 97855073 97855081 97855085 97855091 97855094 97855095 Part Pressure Suction number switch depth stainless setting [ft] steel on/off 97855075 97855083 97855088 - - - 30/50 30/50 30/50 40/60 40/60 40/60 Delivery pressure [psi] 15 20 25 30 35 40 45 50 55 60 65 Flow table [gpm] Max. pressure [psi] Shut off pressure [psi] 5 14.8 14.8 14.7 13.6 - - - - - - - 59 10 13.2 13.2 13.1 12.8 - - - - - - - 57 10.8 10.8 10.7 10.1 15 - - - - - - - 20 - - 8.9 8.9 8.8 7.6 - - - - - 53 25 - - 7.0 7.0 7.0 6.9 5.5 - - - - 51 5 - - 14.3 14.3 14.2 12.6 - - - - - 73 10 - - 13.1 13.1 13.0 12.3 - - - - - 70 15 - - - 11.0 11.0 11.0 10.0 - - - - 20 - - - 9.2 9.1 9.1 9.0 - - - - 66 25 - - - - 7.0 7.0 7.0 6.9 - - - 64 5 - - - - - - - 84 10 - - - - - - - 82 15 - - - - - 11.8 11.6 11.4 10.9 - - 20 - - - - - 9.9 9.8 9.7 9.4 - - 77 25 - - - - - - - 7.9 7.8 7.7 7.3 75 5 - 21.0 20.9 20.7 20.6 20.3 20.2 19.9 - - - 85 10 - 19.0 18.8 18.5 18.2 17.9 17.8 17.5 17.3 - - 82 14.5 14.4 14.3 14.2 13.1 12.8 12.7 12.4 15 - - 20 - - 15.7 15.5 15.4 15.2 15.1 15.0 14.8 14.5 - 25 - - - 5 - 31.8 31.6 31.2 30.8 30.5 30.1 29.1 10 - 28.0 27.7 27.6 27.2 26.9 26.7 26.0 25.1 15 - 23.6 23.3 23.2 23.1 22.8 22.5 22.3 22.1 20.9 20 - - 25 - - 5 - 49.5 49.3 48.9 47.9 46.8 10 - 46.0 45.4 45.0 44.5 43.6 42.0 - 62 75 86 87 13.3 13.1 12.9 12.7 12.5 12.4 12.1 11.9 - 9.7 9.5 9.3 9.1 - 80 80 8.6 8.5 - - - 76 83 - - 81 85 79 76 14.3 14.2 14.1 13.8 13.7 13.4 13.2 - 68 78 20.2 19.9 19.8 19.7 19.4 19.3 19.0 18.5 17.3 - 55 8.9 - 74 - - - - 71 - - - - 69 15 - 37.1 36.8 36.5 36.1 35.5 34.7 33.5 20 - 32.1 31.8 31.6 31.2 30.6 30.4 29.3 25.9 - - - - - 25 - 20.9 20.7 20.6 20.4 20.0 19.5 18.8 18.0 16.5 13.8 JP Jet Pumps Shallow well performance data 73 67 64 62 39 4 Domestic water supply JP Jet Pumps Deep well performance data Delivery pressure [psi] Pump type Pump part number Ejector type NPT Ejector part number Pressure switch on/off Suction depth [ft] 20 30 40 50 60 70 80 90 Flow table [gpm] E 25 JP05D E 25 E 20 97855090 E 25 E 30 E 20 JP20D 97855093 E 25 E 30 40 96654384 96654383 30/50 30/50 97855080 E 30 JP15D 30/50 97855072 E 30 JP07D 96654383 96654384 96654382 96654383 96654384 96654382 96654383 96654384 30/50 40/60 40/60 40/60 40/60 40/60 40/60 30 8 5 - - - - - - 40 6 3 - - - - - - 50 4 1.5 - - - - - - 30 7.7 5.8 2.5 1.3 - - - - 40 5.9 4.3 1.6 - - - - - 50 5 3.4 1 - - - - - 30 10.5 7.9 2.5 - - - - - 40 8.5 5.4 - - - - - - 50 6.4 3.5 - - - - - - 40 - 5.6 2.8 1.7 - - - - 50 - 4.6 2.2 1.3 - - - - 60 - 3.5 1.5 - - - - - 70 - 2.9 - - - - - - 30 - - 15 12.2 9.2 2.6 - - 40 - - 13.5 10.6 7.6 - - - 50 - - 11.6 8.8 5.5 - - - 60 - - 10 7 3.6 - - - 50 - - 12 9.8 7.7 3.5 - - 60 - - 10.8 8.6 6.5 2.5 - - 70 - - 9.7 7.5 5.3 1.7 - - 70 - - 7.9 7.1 6 3.8 2 - 80 - - 7.2 6.5 5.3 3.2 1.6 - 90 - - 6.7 5.8 4.7 2.8 1.2 - 30 - - - 15 9 2 - - 40 - - - 13.4 6.8 - - - 50 - - - 11.7 5 - - - 60 - - - 9.9 2.9 - - - 50 - - - 12.5 7.9 3.7 2 - 60 - - - 11.1 6.7 2.8 1.2 - 70 - - - 9.9 5.5 1.8 - - 80 - - - 8.6 4.3 1 - - 70 - - - 7.9 6.2 4 3 2.3 80 - - - 7.3 5.6 3.4 2.7 1.9 90 - - - 6.7 5 3 2.3 1.5 4 Domestic water supply JP Jet Pumps Dimensions and weights Cast iron shallow well, model JP05S-CI A A1 C H3 H DNA DNM F B E TM05 2221 4611 ØI G Model JP05S-CI Dimensions [in] Part number A A1 B C E F G H H3 I DNA DNM Weight [lbs] 97855073 15.7 15.5 10.4 4.2 7.6 0.5 4.4 8.1 5.6 0.4 1 1 24 Cast iron shallow well, models JP07S-CI, JP10S-CI A A1 C H2 H1 H DNA DNM E F B TM05 2222 4611 I G Dimensions [in] Part number A A1 B C E F G H H1 H2 I DNA DNM Weight [lbs] JP07S-CI 97855081 16.5 16.3 10.4 4.2 7.6 0.5 4.4 8.5 7 5.6 0.4 1 1 28 JP10S-CI 97855085 16.5 16.3 10.4 4.2 7.6 0.5 4.4 8.5 7 5.6 0.4 1 1 30 Model 41 4 Domestic water supply JP Jet Pumps Cast iron shallow well, models JP15S-CI, JP20S-CI A C H1 DNA H DNM TM05 2365 5011 B F E I G Dimensions [in] Part number A B C E F G H H1 I DNA DNM Weight [lbs] JP15S-CI 97855091 21.8 10.2 8.7 13.5 0.5 5.7 10 6.2 0.6 1.25 1 68 JP20S-CI 97855094 21.9 10.2 8.7 13.5 0.5 5.7 10 6.2 0.6 1.25 1 77 Model Cast iron shallow well, models JP30S-CI A C H1 H DNA DNM I G Model JP30S-CI 42 TM05 2366 5011 B F E Dimensions [in] Part number A B C E F G H H1 I DNA DNM Weight [lbs] 97855095 23.4 10.3 5.9 11.3 0.6 6.3 10.4 7.6 0.4 1.5 1.25 71 4 Domestic water supply JP Jet Pumps Shallow well stainless steel, model JP05S-SS A C H3 H 1"NPT 1"NPT E F B TM05 2219 4611 ØI G JP05S-SS Dimensions [in] Part number A B C E F G H H3 I 97855075 16 10.4 4.7 8.1 0.6 4.4 8.3 5.6 0.4 Model Weight [lbs] 18 Shallow well stainless steel, models JP07S-SS, JP10S-SS A C H H2 H1 1"NPT 1"NPT F E B TM05 2220 4611 I G Dimensions [in] Part number A B C E F G H H1 H2 I Weight [lbs] JP07S-SS 97855083 16.8 10.4 4.7 8.1 0.6 4.4 8.5 7.7 5.7 0.4 22 JP10S-SS 97855088 16.8 10.4 4.7 8.1 0.6 4.4 8.5 7.7 5.7 0.4 24 Model 43 4 Domestic water supply JP Jet Pumps Cast iron deep well, models JP05D-CI, JP07D-CI A A1 C DNE H2 H1 H DNA DNM E F B TM05 2218 4611 ØI G Model Part number Dimensions [in] A A1 B C E F G H H1 H2 I DNA DNE DNM Weight [lbs] JP05D-CI 97855072 15 14.6 10.4 3.4 6.7 0.5 4.4 8.1 3.7 1.9 0.4 1.25 1 1 25 JP07D-CI 97855080 15.8 15.4 10.4 3.4 6.7 0.5 4.4 8.5 3.7 1.9 0.4 1.25 1 1 25 Cast iron deep well, models JP15D-CI, JP20D-CI A DNE H1 H2 H DNA DNM F E B A1 I G Model 44 Part number TM05 2367 5011 C Dimensions [in] A A1 B C E F G H H1 H2 I DNA DNE DNM Weight [lbs] JP15D-CI 97855090 15.9 15.2 10.2 2 6.7 0.5 5.7 10 2.1 4.2 0.6 1.25 1 1 63 JP20D-CI 97855093 18.9 18.2 10.2 2 6.7 0.5 5.7 10 2.1 4.2 0.6 1.25 1 1 72 4 Domestic water supply JP Jet Pumps Electrical data Supply voltage: 1 X 115/230V 60Hz 1 X 230V 60Hz Voltage tolerance + / - 6 % Electrical data 60 Hz Pump Model Part Number P2 Power Out [Hp] Service factor [Hp] Phase & voltage I [amps] Phase & voltage I [amps] Capacitor [uF] JP05D-CI 97855072 1/2 1.60 1x115 7.09 1x230 3.61 50 JP05S-CI 97855073 1/2 1.60 1x115 8.21 1x230 4.22 50 JP05S-SS 97855075 1/2 1.60 1x115 8.21 1x230 4.22 50 JP07D-CI 97855080 3/4 1.5 1x115 9.2 1x230 4.67 50 JP07S-CI 97855081 3/4 1.5 1x115 10.3 1x230 5.25 50 JP07S-SS 97855083 3/4 1.5 1x115 10.3 1x230 5.25 50 JP10S-CI 97855085 1 1.40 1x115 13.8 1x230 7.1 80 JP10S-SS 97855088 1 1.40 1x115 13.8 1x230 7.1 80 JP15D-CI 97855090 1-1/2 1.3 - - 1x230 7.6 31.5 JP15S-CI 97855091 1-1/2 1.3 - - 1x230 8 31.5 JP20D-CI 97855093 2 1.25 - - 1x230 8.5 40 JP20S-CI 97855094 2 1.25 - - 1x230 11 40 JP30S-CI 97855095 3 1.15 - - 1x230 12 40 Note: Refer to pump nameplate. Approvals Liquid Pump Subject to alterations. 45 5 Domestic water supply Further documentation 5. Further documentation WebCAPS WebCAPS is a Web-based Computer Aided Product Selection program available on www.grundfos.com. WebCAPS contains detailed information on more than 185,000 Grundfos products in more than 20 languages. In WebCAPS, all information is divided into 6 sections: • Catalog • Literature • Service • Sizing • Replacement • CAD drawings. Catalog This section is based on fields of application and pump types, and contains • technical data • curves (QH, Eta, P1, P2, etc) which can be adapted to the density and viscosity of the pumped liquid and show the number of pumps in operation • product photos • dimensional drawings • wiring diagrams • quotation texts, etc. Literature In this section you can access all the latest documents of a given pump, such as • product guides • installation and operating instructions • service documentation, such as Service kit catalog and Service kit instructions • quick guides • product brochures, etc. Service This section contains an easy-to-use interactive service catalog. Here you can find and identify service parts of both existing and discontinued Grundfos pumps. Furthermore, this section contains service videos showing you how to replace service parts. 46 5 Sizing 0 Further documentation Domestic water supply 1 This section is based on different fields of application and installation examples, and gives easy step-by-step instructions in how to • select the most suitable and efficient pump for your installation • carry out advanced calculations based on energy consumption, payback periods, load profiles, life cycle costs, etc. • analyze your selected pump via the built-in life cycle cost tool • determine the flow velocity in wastewater applications, etc. Replacement In this section you find a guide to selecting and comparing replacement data of an installed pump in order to replace the pump with a more efficient Grundfos pump. The section contains replacement data of a wide range of pumps produced by other manufacturers than Grundfos. Based on an easy step-by-step guide, you can compare Grundfos pumps with the one you have installed on your site. When you have specified the installed pump, the guide will suggest a number of Grundfos pumps which can improve both comfort and efficiency. CAD drawings In this section it is possible to download 2-dimensional (2D) and 3-dimensional (3D) CAD drawings of most Grundfos pumps. These formats are available in WebCAPS: 2-dimensional drawings: • .dxf, wireframe drawings • .dwg, wireframe drawings. 3-dimensional drawings: • .dwg, wireframe drawings (without surfaces) • .stp, solid drawings (with surfaces) • .eprt, E-drawings. WinCAPS WinCAPS is a Windows-based Computer Aided Product Selection program containing detailed information on more than 185,000 Grundfos products in more than 20 languages. The program contains the same features and functions as WebCAPS, but is an ideal solution if no Internet connection is available. WinCAPS is available on CD-ROM and updated once a year. Fig. 21 WinCAPS CD-ROM 47 Being responsible is our foundation Thinking ahead makes it possible Innovation is the essence L-DWS-PG-01 0612 The name Grundfos, the Grundfos logo, and the payoff Be–Think–Innovate are registrated trademarks owned by Grundfos Management A/S or Grundfos A/S, Denmark. All rights reserved worldwide. ECM: - GRUNDFOS Pumps Corporation 17100 West 118th Terrace Olathe, Kansas 66061 Phone: +1-913-227-3400 Telefax: +1-913-227-3500 GRUNDFOS Canada Inc. 2941 Brighton Road Oakville, Ontario L6H 6C9 Canada Phone: +1-905 829 9533 Telefax: +1-905 829 9512 Bombas GRUNDFOS de Mexico S.A. de C.V. Boulevard TLC No. 15 Parque Industrial Stiva Aeropuerto Apodaca, N.L. Mexico 66600 Phone: +52-81-8144 4000 Telefax: +52-81-8144 4010
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.6 Linearized : Yes Page Mode : UseOutlines XMP Toolkit : Adobe XMP Core 4.0-c321 44.398116, Tue Aug 04 2009 14:24:39 Create Date : 2012:06:14 17:11:20Z Creator Tool : FrameMaker 10.0 Modify Date : 2012:06:14 17:22:56+02:00 Metadata Date : 2012:06:14 17:22:56+02:00 Producer : Acrobat Distiller 10.0.0 (Windows) Format : application/pdf Title : untitled Document ID : uuid:238d7c1e-7794-45bf-a0bb-5cb1ece743cb Instance ID : uuid:ba69f705-b3e0-4bc5-b323-08a3171c2d79 Page Count : 48 Language : en Creator : FrameMaker 10.0EXIF Metadata provided by EXIF.tools