THERM-X-TROL

®

THERMAL EXPANSION ABSORBERS
The Best Solution for
Controlling Thermal Expansion

n On
As See

THERM-X-TROL® Expansion Tanks
Table of Contents
THERM-X-TROL® Expansion Tanks.......... 2
What is Thermal Expansion?..................... 2
THERM-X-TROL®: The Market Leader...... 3
Pressure Increase in Closed Piping System. 4
Precise Sizing Procedure.......................... 5
ASME Thermal-X-Trol®.............................. 6
Non-ASME Thermal-X-Trol®...................... 7
Quick Sizing............................................... 8

What Is Thermal Expansion?
With modern plumbing codes mandating backflow prevention,
thermal expansion can cause pressure buildup in domestic water
systems. When demand is put upon a potable water system,
hot water is drawn from the water heater. Cold water from the
supply line enters the water heater
to replenish it. The cold water is
heated to replace the hot water
used. With the installation of a
backflow preventer, check valve
or pressure reducing valve on the
supply line, the water heater and
the system piping form a closed
plumbing system under pressure.
As the water is heated, thermal
expansion occurs. Pressure increases until the relief valve opens
and the expanded water spills from the water heater. This spillage
results in wasted energy and a potential safety hazard. (See
Diagram 1)

Closed Potable Hot Water System
without THERM-X-TROL®
Backflow preventer, pressure reducing valve or other one-way device
causes expanded (heated) water to build pressure causing the relief valve to
open resulting in…
• Wasted energy
• Shortened water heater life
• Wasted municipal water and sewer dollars
• Potential safety hazard

Unsafe pressure increases
without THERM-X-TROL®
Fixture
Closed

Backflow Preventor

Cold Water Supply

SPILL

The THERM-X-TROL® is designed to eliminate this problem by providing
control of maximum pressures at a level below the relief valve setting. It also
provides an additional space in the system to accommodate the increased
volume of water created by thermal expansion, returning it to the system
when hot water delivery is demanded. Maximum pressure is kept well
below the relief valve setting by the THERM-X-TROL®, with its pre-charged
air cushion that is separated from system water. The relief valve does not
open, therefore spillage is eliminated (Diagram 2).

Closed Potable Hot Water System
with THERM-X-TROL®
Expanded (heated) water is absorbed by THERM-X-TROL® which means…
• Water heater and fixtures are protected
• Eliminates energy and water waste, saving money
• No dangerous pressure build up in the system
• Relief valves will not open
• Potential safety hazard reduced

2

Diagram 1

Cold Water Supply
Backflow
Preventor
THERM-X-TROL®

THERM-X-TROL®: The Market Leader
•	#1 choice of Professional Installers
•	Safest and most cost effective way to control
Thermal Expansion
• Easy to install
•	The innovator of Thermal Expansion Control in
Closed Potable Hot Water Systems
•	Broadest line of sizes and models

•	Recognized Industry leader in Quality, Design,
Manufacturing, Delivery and Service
•	Extensive Network of Plumbing & Heating
Distributors
•	First to obtain NSF/ANSI 61, IAPMO, SBCCI & City
of Los Angeles listings
•	First to offer 5 year limited warranty

Product Features
High-grade connector

Deep Drawn Steel Domes for
maximum strength & pressure rating

Rigid Polypropylene Liner for
corrosion resistant reservoir

Butyl diaphragm for long life
expectancy

Diaphragm Hoop Ring mechanically
grooved for permanent air-tight seal

Welded Steel Construction

Welded Air Charge Fitting with
protective plastic cap for corrosion
resistance and maximum air-tight seal

3

Pressure Increase in Closed Piping System

P
R
E
S
S
U
R
E
P
S
I
G

600
500
400

WATER

300
200
100
0
65

70

75

80

85

TEMPERATURE - °F

4

90

95

100

Precise Sizing Procedure - For Special Applications
The procedure for sizing the Therm-X-Trol® for
any application depends on four (4) vital pieces of
information:
1. ASME or non-ASME requirement
2 Calculated thermally expanded water volume
3.	Minimum water pressure experienced at the tank
location

Critical Sizing AMTROL® Therm-X-Trol®
1. Total Water Heater Volume (Gallons)
2. Water Expansion Factor (Table I)
3. Calculate Expanded Water (Gallons)
		 (Line 1 x Line 2)
4. Design Pressure Factor (Table II)
5. Therm-X-Trol Volume Required (Gallons)
		 (Line 3 x Line 4)
6. Select Therm-X-Trol® Model (pg. 6 & 7)

4.	Maximum water pressure allowable at the tank
location

Critical Sizing AMTROL® Therm-X-Trol®: EXAMPLE
The tank required for any application can be sized with
the following equation:

Tv = Design Pressure Factor X expanded water
Where Tv is the total Thermal-X-Trol® volume required
in gallons.

1. Total Water Heater Volume (Gallons)		
2. Water Expansion Factor (Table I)
3. Calculate Expanded Water (Gallons)
		 (Line 1 x Line 2) = (240 x .0179)
4. Design Pressure Factor (Table II)		
5. Therm-X-Trol Volume Required (Gallons)		
		 (Line 3 x Line 4) = (4.3 x 2.1)
6. Select Therm-X-Trol® Model (pg. 6 & 7)		
				

240
0.0179
4.3
2.1
9.0
ST-25V
ST30V-C

Note: The Therm-X-Trol® air pressure should be equal to static line pressure.

Example: A 240 gallon water heater with a 150°F aquastat
setting is installed with a 125 psi maximum pressure
requirement. For a static supply line pressure of 60
psi, what Therm-X-Trol® model is required for critical
protection?

		
		
		
		
		
		
		
		
		
		
		

TABLE I Expansion Factor
Operating (Design)
Temperature of
Water Heater (Tank)
100˚F
120˚F
130˚F
140˚F
150˚F
160˚F
170˚F
180˚F

* Based on the initial temperature of 40˚F

Expansion Factor*
(Percentage of Water
Volume Increase)
0.0062		
0.6%
0.0100		
1.0%
0.0124		
1.2%
0.0150		
1.5%
0.0179		
1.8%
0.0209		
2.0%
0.0242		
2.4%
0.0276		
2.8%

For conditions not shown in table, use equation:
DPF=

Max. Allow. Pressure + 14.7
Max. Allow. Pressure - Line Pressure

TABLE II Design Pressure Factor: DPF
Maximum
Allowable
Pressure
		
		
100
		
		
		
		
125
		
		
		
		
150
		
		

Line
Pressure
psi
40
50
60
70
80
40
50
60
70
80
40
50
60
70
80

Design
Pressure
Factor (DPF)
1.9
2.3
2.9
3.8
5.7
1.6
1.9
2.1
2.5
3.1
1.5
1.6
1.8
2.1
2.4

5

ASME THERM-X-TROL®
A

Code Applications

A

• Commercial Water Heaters
B

B

• Laundromats
• Hospitals and Nursing Homes

ST-5-C, ST-12-C

• Car Washes

ST-20V-C to ST-70V-C

• Dishwashers
A

• Plant Washrooms
• Hotels and Motels

A

• Restaurants
B

• Schools and Dormitories
B

• Other Applications as Required by Code

ST-80V-C to ST-210V-C

ST-447-C to ST-457-C

THERM-X-TROL® ASME Specifications
Model
No.
ST-5-C
ST-12-C
ST-20V-C
ST-30V-C
ST-42V-C
ST-60V-C
ST-70V-C
ST-80V-C
ST-120V-C
ST-180V-C
ST-210V-C
ST-447-C
ST-448-C
ST-449-C
ST-450-C
ST-451-C
ST-452-C
ST-453-C
ST-454-C
ST-455-C
ST-456-C
ST-457-C

Max. Working
Pressure (PSIG)
150
150
150
150
150
150
150
150
150
150
150
125
125
125
125
125
125
125
125
125
125
125

Total Volume
Maximum
Diameter
(Gals.)
Acceptance Factor
(A)
2.1
.42
10”
6.4
.50
12”
8.0
.40
12”
14.0
.64
16 1/4”
17.5
.64
16 1/4”
25.0
.45
16 1/4”
34.0
.33
16 1/4”
53.0
.64
24”
66.0
.51
24”
77.0
.44
24”
90.0
.38
24”
53.0
.65
24”
80.0
.65
24”
106.0
.65
24”
132.0
.65
24”
158.0
.65
30”
211.0
.65
30”
264.0
.65
36”
317.0
.65
36”
370.0
.65
36”
422.0
.65
48”
528.0
.65
48”

Height
(B)
10 3/8”
15 5/8”
19 1/2”
19 1/8”
24 1/4”
34”
45 3/4”
40 1/2”
47 3/4”
52 5/8”
60”
45 1/4”
59 1/8”
73 1/8”
86 5/8”
73 1/4”
91”
85 5/8”
98”
110 3/8”
81 7/8”
97 1/4”

System
Connection
3
/4” NPT
3
/4” NPT
3
/4” NPT
3
/4” NPT
3
/4” NPT
3
/4” NPT
3
/4” NPT
1 1/4” NPT
1 1/4” NPT
1 1/4” NPT
1 1/4” NPT
2” NPT
2” NPT
2” NPT
2” NPT
2” NPT
2” NPT
3” NPT
3” NPT
3” NPT
3” NPT
3” NPT

Maximum Allowable Working Temperature: ST-5-C through ST-210V-C: 200°F; ST-447-C through ST-457-C: 240°F Standard Factory Precharge: 55 PSIG.

6

Ship Weight
(lbs)
21
26
41
84
90
96
123
229
258
288
318
263
308
353
391
508
760
810
914
1,018
1,655
1,925

Non-ASME THERM-X-TROL®
A

General Usage
• Residential Water Heaters

B

• Office Buildings
• Apartment Buildings
• Dormitories

ST-5, ST-8, ST-12

• Elderly Housing

A

• Extended Care Facilities
• Condominiums/Multiple Residential
• Food Service
• Laundromats

B

• Hospitals
• Other General-Use Hot Water Systems

ST-25V through ST-210V

THERM-X-TROL® Non-ASME Specifications
Model
No.
ST-5
ST-8
ST-12
ST-25V
ST-30V
ST-42V
ST-60V
ST-80V
ST-180V
ST-200V
ST-210V
ST-451
ST-452
ST-453
ST-454
ST-455
ST-456
ST-457

Total Volume
Maximum
(Gals.)
Acceptance Factor
2.0
.45
3.2
.45
4.4
.55
10.3
1.0
14.0
.81
20.0
.57
34.0
.35
44.0
.77
62.0
.55
81.0
.41
86.0
.54
158.0
.65
211.0
.65
264.0
.65
317.0
.65
370.0
.65
422.0
.65
528.0
.65

Diameter
(A)
8”
9”
11”
15 3/8”
15 3/8”
15 3/8”
22”
22”
22”
22”
26”
73 1/4”
91”
85 5/8”
98”
110 3/8”
81 7/8”
97 1/4”

Height
(B)
12 5/8”
15”
15”
19 1/4”
23 7/8”
31 5/8”
29 5/8”
36”
46 3/4”
56 3/8”
47 1/4”
30”
30”
36”
36”
36”
48”
48”

System
Connection
3
/4” NPT
3
/4” NPT
3
/4” NPT
3
/4” NPT
3
/4” NPT
3
/4” NPT
1 1/4” NPT
1 1/4” NPT
1 1/4” NPT
1 1/4” NPT
1 1/4” NPT
2” NPT
2” NPT
3” NPT
3” NPT
3” NPT
3” NPT
3” NPT

Ship Weight
(lbs)
5
7
9
23
25
33
61
69
92
103
123
508
760
810
914
1,018
1,655
1,925

Maximum Working Pressure: 150 PSI. All Models listed by NSF 61 (excluding ST-451 – ST-457); Maximum Allowable Working Temperature: ST-5 through
ST-210V: 200°F; ST-451 through ST-457: 240°F; Standard Factory Precharge: 40 PSIG (ST-5 – ST-210V); 55 PSIG (ST-451 – ST-457)

7

THERM-X-TROL®
THERM-X-TROL®
The THERM-X-TROL® from AMTROL is designed to protect domestic
water heaters from the effects of thermal expansion. Installation is
easy; just tee it into the cold water inlet (before the water heater) as
shown in Diagram 3.

THERM-X-TROL®
Quick-Sizing Chart
Sizing Charts are based on 40°F incoming
water temperature and a 150 psi T & P
safety relief valve.

BFP, Check or PRV
CWS

Outer
Steel Shell

Rigid
Polypropylene
Liner

Hot Water

Expanded
Water

Heavy Duty
Butyl Diaphragm

T&P
Valve

Water
Heater

Always adjust THERM-X-TROL®
pre-charge to equal city water
supply pressure.
Diagram 3

If your Plumbing Code requires a Backflow
Preventer,Check Valve or Pressure Reducing Valve...
You Need a THERM-X-TROL® on Every Job!

* For multiple heater, use the total volume of the heaters
plus any storage tanks.
** Therm-X-Trol Precharge must be set to equal Static
Supply Pressure prior to installation.

Corporate Headquarters
1400 Division Road, West Warwick, RI USA 02893
Telephone: 401-884-6300 • Fax: 401-884-5276

w w w . a m t r o l . c o m

AMTROL Canada, Ltd.
275 Shoemaker Street, Kitchener, Ontario N2E 3B3
Telephone: 519-478-1138 • Fax: 519-748-4231

The AMTROL® logo, AMTROL and Therm-X-Trol are registered trademarks of AMTROL Inc. and its affiliates in the US and elsewhere. AMTROL Inc. and it’s subsidiaries reserve the right to alter designs and specifications without prior notice.

MC# 4090 (06/09)

©2009 AMTROL Inc.
Printed in USA



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 4.0-c316 44.253921, Sun Oct 01 2006 17:08:23
Modify Date                     : 2009:06:24 09:53:43-04:00
Create Date                     : 2009:06:24 09:53:30-04:00
Metadata Date                   : 2009:06:24 09:53:43-04:00
Format                          : application/pdf
Document ID                     : uuid:3bd13e19-c0aa-4dc0-9726-779f0f074b01
Instance ID                     : uuid:a749c2cb-7eee-46cf-b678-d94d4dd4e1bb
Page Count                      : 8
EXIF Metadata provided by EXIF.tools

Navigation menu