538313 1 Goulds 4SD Sewage Pump Brochure
: Pump 538313 1 Goulds 4Sd Sewage Pump Brochure 538313_1_Goulds 4SD Sewage Pump Brochure pdf
Open the PDF directly: View PDF .
Page Count: 4
4SD
SUBMERSIBLE SEWAGE PUMP
DUAL SEAL WITH SEAL SENSOR PROBE
TECHNICAL BROCHURE
B4SD R1
PAGE 2
Wastewater
Goulds Water Technology
APPLICATIONS
Used in a variety of residential, commercial and
industrial applications such as:
• Sewage systems
• Flood and pollution control
• Dewatering/Efuent
• Farms
• Hospitals
• Trailer courts
• Motels
SPECIFICATIONS
Pump:
• Maximum solid size: 3”
• Discharge size: 4”, 125 # ANSI ange
• Maximum capacity: 620 GPM
• Maximum total head: 60 feet
• 300 Series stainess steel fasteners
• 20’ Power cord
• Standard silicon carbide/silicon carbide outer seal
Motor:
• Maximum ambient temperature: 104º F (40º C)
continuous duty, 140º F (60º C) intermittent duty
• Rated for continuous duty when fully submerged
• Insulation: Class F
• 60 Hertz
• Single row ball bearings
• 300 Series stainless steel keyed shaft
Single Phase:
• 1.5 - 5 HP
• 208 and 230 volts
• Built-in thermal overloads with automatic reset
• Built-in capacitors
Three Phase:
• 1.5 - 7.5 HP
• 200, 230, 460 and 575 volts
• Class 10 overload protection must be provided in
control panel
MOTORS
• Fully submerged in oil-lled chamber. High grade
turbine oil surrounds motor for more efcient heat
dissipation, permanent lubrication of bearings and
mechanical seal for complete protection against
outside environment.
• Class F insulation
• Designed for Continuous Operation: Pump ratings
are within the motor manu facturer’s recommended
working limits and can be operated continuously
without damage when fully submerged.
• Bearings: Upper and lower heavy duty ball bearing
construction for precision positioning of parts and
to carry thrust loads.
• Power and Control Cables: Severe duty rated,
oil and water resistant. Epoxy seal on motor end
provides secondary moisture barrier in case of outer
jacket damage and to prevent oil wicking. 20 foot
standard with optional lengths available.
• O-ring: Assures positive sealing against
contaminants and oil leakage.
FEATURES
Impeller: Cast iron, two vane semi-open, non-clog
with pump-out vanes for mechanical seal protection.
Balanced for smooth operation. Silicon bronze
impeller available as an option.
Casing: Heavy duty cast iron, volute type for maximum
efciency. 4" ange conforms to 125 # ANSI standard.
Connects to A10-40 or A10-60 guide rail system.
Dual Mechanical Seals: Silicon carbide vs. silicon
carbide outer seal and ceramic vs. carbon inner seal,
stainless steel metal parts, BUNA-N elastomers. Upper
and lower shaft seals are positioned independently
and are separated by an oil-lled chamber.
CU
S
®
Tested to UL 778 and CSA 22.2 108 Standards
By Canadian Standards Association
File #LR38549
Seal Sensor Probe: Located in oil-lled chamber.
If pumpage should begin to leak past lower seal it
indicates to pump control panel a fault has occurred.
Requires optional Seal Fail Circuit in the control panel.
Shaft: 300 series stainless steel keyed design.
Fasteners: 300 series stainless steel.
Capable of running dry with out damage to
components.
AGENCY LISTINGS
PAGE 3
Wastewater
Goulds Water Technology
MODEL AND MOTOR INFORMATION
1st, 2nd and 3rd Character – Discharge Size and Type
4SD = 4" discharge, 3" solids handling, dual seal with
seal fail probe in pump.
4th Character – Mechanical Seals
5 = Silicon carbide/silicon carbide/BUNA – lower seal
and carbon/ceramic/BUNA – upper seal (standard)
3 = Silicon carbide/tungsten carbide/BUNA – lower
seal and carbon/ceramic/BUNA – upper seal (op-
tional)
5th Character – Cycle/RPM
2 = 60 Hz/1750 RPM 6 = 50 Hz/1450 RPM
6th Character – Horsepower
F = 1½ HP H = 3 HP K = 7½ HP
G = 2 HP J = 5 HP
7th Character – Phase/Voltage
1 = single phase, 230 V 4 = three phase, 460 V
NOMENCLATURE DESCRIPTION
2 = three phase, 200 V* 5 = three phase, 575 V
3 = three phase, 230 V 8 = single phase, 208 V
* Not available on 71⁄2 H P.
8th Character – Impeller Diameter
A = 7.25", 5 HP D = 6.25", 11⁄2 HP
B = 7.00", 3 HP E = 5.63", 11⁄2 HP
C = 6.63", 2 HP F = 7.69", 71⁄2 HP
9th Character – Cord Length (Power and Sensor)
A = 20' (standard) F = 50'
D = 30' J = 100'
10th Character – Options
B = Bronze impeller
E = Epoxy paint
F = Both epoxy paint and bronze impeller
11th Character – Option
H = Pilot duty thermal sensors (3 phase only!!)
Order
Number HP Phase Volts RPM
Impeller Maximum
Amps
Locked
Rotor
Amps
KVA
Code
Power
Cable
F.L. Motor
Efciency %
Resistance Weight
(lbs.)
Dia. (In.) Code Start Line-Line
4SD52F8EA
1.5
1208
1750
5.63 E
17.2 50.8 B 14/3 80 1.1 0.9
195
4SD52F1EA 230 14.7 29.5 E 70 1.4 1.8
4SD52F2EA
3
200 11.5 40.9 H
14/4
81
NA
1.7
4SD52F3EA 230 10.0 40.0 F 83 2.3
4SD52F4EA 460 5.0 20.0 F 83 9.3
4SD52F5EA 575 4.0 14.4 H 74 14.8
4SD52F8DA
1.5
1208
6.25 D
17.2 50.8 B 14/3 80 1.1 0.9
195
4SD52F1DA 230 14.7 29.5 E 70 1.4 1.8
4SD52F2DA
3
200 11.5 40.9 H
14/4
81
NA
1.7
4SD52F3DA 230 10.0 40.0 F 83 2.3
4SD52F4DA 460 5.0 20.0 F 83 9.3
4SD52F5DA 575 4.0 14.4 H 74 14.8
4SD52G8CA
2
1208
6.63 C
20.3 50.8 B 14/3 80 1.1 0.9
200
4SD52G1CA 230 17.3 36.9 D 75 1.4 1.5
4SD52G2CA
3
200 13.3 40.9 H
14/4
81
NA
1.7
4SD52G3CA 230 11.6 40.0 F 83 2.3
4SD52G4CA 460 5.8 20.0 F 83 9.3
4SD52G5CA 575 4.6 14.4 H 74 14.8
4SD52H8BA
3
1208
7.00 B
25.5 50.8 B 10/3 80 1.1 0.9 208
4SD52H1BA 230 21.5 46.4 C 79 1.0 1.0
4SD52H2BA
3
200 16.6 53.8 G 10/4 85
NA
1.3
205
4SD52H3BA 230 14.4 49.5 H
14/4
83 1.9
4SD52H4BA 460 7.2 24.8 H 83 7.5
4SD52H5BA 575 5.8 17.3 G 78 11.6
4SD52J1AA
5
1 230
7.25 A
26.5 57.7 A 10/3 80 1.0 0.8 213
4SD52J2AA
3
200 19.1 73.9 F10/4 84
NA
0.9
210
4SD52J3AA 230 16.6 63.6 E 85 1.2
4SD52J4AA 460 8.3 31.8 E 14/4 85 4.8
4SD52J5AA 575 6.6 22.8 E 80 7.4
4SD52K3FA
7.5 3
230
7.69 F
23.0 105.0 G
10/4
83
NA
0.7
2254SD52K4FA 460 11.5 52.5 G 83 2.8
4SD52K5FA 575 9.2 42.0 E 84 4.4
2
4
3
2
8
1
2
6
5
7
2
6
5
7
2
2
4
3
2
2
8
1
3.50"
4" 125 #
ANSI FLANGE
6.75"
28.25"
KICKBACK
ROTATION
12.62"
15.75"
9.50"
APPLICATION DATA
CONSTRUCTION DETAILS
STANDARD PARTS
Goulds is a registered trademark of Goulds Pumps, Inc. and is used under license.
© 2014 Xylem Inc. B4SD R1 November 2014
Xylem Inc.
2881 East Bayard Street Ext., Suite A
Seneca Falls, NY 13148
Phone: (866) 325-4210
Fax: (888) 322-5877
www.gouldswatertechnology.com
Maximum Solid Size 3"
Minimum Casing Thickness 5⁄16"
Casing Corrosion Allowance 1⁄8"
Maximum Working Pressure 30 PSI
Maximum Submergence 50 feet
Minimum Submergence
Fully submerged for continuous operation
6" below top of motor for intermittent
operation
Maximum Environmental
Temperature
40ºC (104ºF) continuous operation
60ºC (140ºF) intermittent operation
Ball Bearing
Upper
11⁄2 – 5 HP single and three phase: single row ball– SKF™ 6204-2Z
71⁄2 HP three phase: single row ball – SKF™ 6204-2Z
Lower
11⁄2 – 5 HP single and three phase: single row ball – SKF™ 5206-2Z
71⁄2 HP three phase: double row ball – SKF™ 5206-2Z
Mechanical Seals – Standard Upper Carbon/Ceramic; Type 21
Lower Silicon Carbon/Silicon Carbon; Type 31
Mechanical Seals – Optional Lower Silicon Carbide/Tungsten Carbide: Type 21
O-Ring – Stufng Box BUNA-N, AS 568A-265
O-Ring – Motor Cover BUNA-N, AS 568A-374
Power Cable – Type
14/3, type SJTOW: single phase, 1⁄2 and 2 HP
14/4, type STOW: single phase, 1½ - 3 HP and 5
HP, 460 V
10/4, type STOW: single phase, 3 and 5 HP, three
phase 5 HP, 230 V
and 7½ HP
Sensor Cable – Type 16/2, type SJTOW: seal sensor only
18/4, type SJTOW: seal/heat sensor
Motor Cover Gray Cast Iron – ASTM A48 Class 30
Bearing Housing Gray Cast Iron – ASTM A48 Class 30
Seal Housing Gray Cast Iron – ASTM A48 Class 30
Casing Gray Cast Iron – ASTM A48 Class 30
Impeller Gray Cast Iron – ASTM A48 or Cast Bronze – ASTM
B584 C87600
Motor Shaft AISI 300 Series Stainless Steel
Motor Design NEMA 56 Frame, oil lled with Class F Insulation
Motor Overload Protection
Single Phase: on winding thermal overload
protection
Three Phase: require ambient compensated Class
10, quick trip overloads in the control panel.
Motor Seal Fail (Moisture)
Detection
Seal fail sensor in an oil-lled seal chamber.
Connect to an optional relay in control panel.
Optional Motor Thermal
Protection
Normally closed on-winding thermostats open
at 275º F (135 ºC) and close at 112º F (78º C).
Require terminal connection in the control panel.
External Hardware 300 Series Stainless Steel
Impeller Type Semi-open with pump out vanes on back shroud
Oil Capacity – Seal Chamber
1.75 quarts
Oil Capacity – Motor
Chamber
1½-5 HP single and three phase: 7 quarts
7½ HP three phase: 6.5 quarts
DIMENSIONS
(All dimensions are in inches. Do not use for construction purposes.)
Item Material
No. Part Name Standard Optional
1 Impeller, non-clog 1003 1179
2 Castings 1003
3 Shaft-Keyed 300 Series SS
4 Fasteners 300 Series SS
5 Ball bearings Steel
6 Power cable STOW, 20 feet Additional
Seal sensor cable lengths
7 O-ring BUNA-N
Outer Elasto- Metal
Mech. Service Rotary Stationary mers Parts
Seal
8 OPT Heavy Silicon Tungsten BUNA-N 300
duty Carbide Carbide Series SS
STD Mild Silicon Carbide BUNA-N 300
abrasives Series SS
Material Code Engineering Standard
1003 Cast iron — ASTM A48 Class 30
1179 Silicon bronze — ASTM C87600
MATERIALS OF CONSTRUCTION