TECHNICAL BROCHURE
BAQUABII R2

* Available up to 100 GPM systems

Aquavar ABII
VARIABLE SPEED CONSTANT PRESSURE SYSTEMS

CentriPro
Residential and Commercial Water Systems
FEATURES
The AB2 variable speed pump controller and complete booster package kits, provide an
economical answer for municipal water district customers with low water pressure. Both domestic and light commercial applications can benefit. As water use increases, the controller
changes pump speed to maintain pressure. Large supply tanks are eliminated and less wear
and tear on your pump and motor.
Think of it as “Cruise Control” for your pump! The AB2 is available with a range of flow rates
to handle homes with up to four baths, irrigation, filtration and fire suppression systems.
Light commercial applications up to 100 GPM at 45 PSI boost. The AB2 is available as either
a separate controller or as part of a complete pump package with everything you need to
plumb it to a domestic water line.

The AquaBoost Advantage

0

Pressure

+

Pressure

+

Flow

+ 0

Typical home water pressure
drops when demand is high.

Flow

+

The AquaBoost makes up the
pressure difference at peak demand
for constant home water pressure.

TANK SIZING
Diaphragm Tank Sizing and Pre-Set Pressure
Recommendations:
Diaphragm type (captive air) tanks are required on
these systems.
Table 1: Tank Sizing Selection
Recommended Tanks

Maximum
Pump GPM

Total Volume

10

1.9

V6P

24

4.9

V15P

36

7.3

V25P

70

13.9

V45

100

19.9

V60

PAGE 2

Order Number

Use Total Tank Volume, to select the proper tank size.
The total tank volume should be approximately 20%
of the pump’s maximum flow. For example, when
using a 10 gpm pump the system requires a minimum
2 gallon (total volume) tank.
The tank sizing recommendations are field proven to
prevent objectionable pressure drops on start-up and
provide smooth operation for the majority of variable
speed pump systems.
Set the tank pressure, while tank is empty of water, to
20 psi below the desired system pressure setting. Ex.
for a 50 psi system pressure, charge the tank to 30 psi.

CentriPro
Residential and Commercial Water Systems
INPUT AND OUTPUT POWER (VOLTAGE AND PHASE)
• All 1AB2 and 2AB2 require single-phase input power	
o All will work on 1Ø, 208-230V input power	
o 1151AB2’s will work on 1Ø, 115V input power

• All controllers output three-phase, 230 Volt power
• All pumps are equipped with three-phase motors

*1AB2 – Controller (1151AB2 for 115V)

2AB22HM1F2E0

• 4.2 Amp, 208-230 V, single phase input
• 1 HP variable speed controller
• Wall mount set • Transducer • Pre-wired
• Pump and tank not included

• 2 HP controller • Wall mount kit • 208-230 V input
• HMS stainless steel pump • Transducer
• V6P (2 gallon) tank, pressure gauge and discharge
pipe tee
• Controller is pre-wired. Flows to 30 GPM.

2AB2 – Controller
• 6.9 Amp, 208-230 V, single phase input
• 2 HP variable speed controller
• Wall mount set • Transducer • Pre-wired
• Pump and tank not included

*1AB2LB1035
• 1 HP controller • Wall mount set
• LB stainless steel jet pump • Transducer
• Discharge tee • V6P tank, pressure gauge
• Controller is pre-wired to the pump.
Flows to 15 GPM.

2AB21MC1F2B2
• 2 HP controller • Wall mount set • 208-230 V input
• MCC cast iron / stainless steel pump
• Transducer • V6P (2 gallon) tank and pressure gauge
• Controller is pre-wired. Flows to 27 GPM.

2AB21MC1G2A2
• 2 HP controller • Wall mount kit • 208-230 V input
• MCC cast iron / stainless steel pump
• Transducer • V6P (2 gallon) tank and pressure gauge
• Controller is pre-wired. Flows to 32 GPM.

*1AB21HM1E2D0
• 1 HP controller • Wall mount kit • 208-230 V input
• HMS stainless steel pump • Transducer
• V6P (2 gallon) tank and discharge pipe tee
• Controller is pre-wired. Flows to 20 GPM.

*1AB22HM1E2D0
• 1 HP controller • Wall mount kit • 208-230 V input
• HMS stainless steel pump • Transducer
• V6P (2 gallon) tank, pressure gauge and discharge
pipe tee
• Controller is pre-wired. Flows to 30 GPM.

**3AB2LCB1H2D0
• 3 HP controller • Wall mount kit • 208-230 V input
• LCB stainless steel pump • Transducer
• Pressure gauge and discharge pipe tee
• Controller is pre-wired. Flows to 50 GPM.

**2AB22MC1G2D2
• 2 HP controller • Wall mount kit • 208-230 V input
• MCC cast iron/stainless steel impeller pump
• Pressure transducer
• Pressure gauge, 1¼" bronze discharge tank tee
• Controller and motor are pre-wired. Flows to 80
GPM.

**5AB22MC1J2K2
• 5 HP controller • Wall mount • 208-230 V input
• MCC cast iron/stainless impeller pump
• Pressure transducer
• Pressure gauge, 1¼" bronze tank tee
• Controller and motor are pre-wired. Flows to 100
GPM.

**5AB2LCC1J2D0
• 5 HP controller • Wall mount • 208-230 V input
• LCC stainless steel pump • Pressure transducer
• Pressure gauge, 1¼" bronze tank tee
• Controller and motor are pre-wired. Flows to 70
GPM.
* 1 HP available in 115 input volt models, add a 115 prefix
to order number; ex. 1151AB2LB1035.
** Tank not included, order separately.
See Tank Sizing guide on previous page.

PAGE 3

CentriPro
Residential and Commercial Water Systems
SYSTEM SELECTION
	 PSI	
2-10 	 20 	
30 	
40 	
50 	
60 	
70 	
80 	
90 	
100
	
BOOST	GPM	GPM	GPM	GPM	 GPM	GPM	GPM	GPM	GPM	GPM
	20	

1	3	3	5	 5	9	9	9	10	
10

	25	

1	3	3	9	 9	9	9	10	10	
10

	30	

1	 3	 3	 9	 9	 10	10	10	10	10

	35	

1	 3	 3	 9	 9	 10	10	10	10	10

	40	

1	 3	 3	 7	 7	 10	10	10	10	10

	45	

1	

3	

3	

7	

8	

10	

10	

10	

10	

	50	

1	

3	

4	

7	

8	

10	

10	

10	

10

	55	

1	

3	

4	

7	

8	

10	

10

	60	

1	

4	

7	

8	

8

	65	

2	

4	

7	

8	

8

	70	

2	

4	

8	

8

	75	

4	

4	

8

	80	

4

	 *1	1AB2LB1035 (1 HP, stainless steel pump, 1" discharge, 1¼" suction)
	 *2	1AB21HM1E2D0 (1 HP, stainless steel pump, 1" discharge, 1¼" suction)
	 *3	1AB22HM1E2D0 (1 HP, stainless steel pump, 1" discharge, 1¼" suction)
	4	 2AB22HM1F2E0 (1½ HP, stainless steel pump, 1" discharge, 1¼" suction)
	5	 2AB21MC1F2B2 (1½ HP, cast iron pump, 1" discharge, 1¼" suction)
	6	 2AB21MC1G2A2 (2 HP, cast iron pump, 1" discharge, 1¼" suction)
	7	 3AB2LCB1H2D0 (3 HP, stainless steel pump, 1" discharge, 1¼" suction)
	8	 5AB2LCC1J2D0 (5 HP, stainless steel pump, 1" discharge, 1½" suction)
	9	 2AB22MC1G2D2 (2 HP, cast iron pump, 1¼" discharge, 1½" suction)
	10	 5AB22MC1J2K2 (5 HP, cast iron pump, 1¼" discharge, 1½" suction)
* 1 HP available in 115 volt input models. See Price Pages.
Items 7 thru 10 do not include tank. Recommend bladder tank, sized to 20% of pump flow (gpm).
See "Tank Sizing" on page 2.
NOTE: PSI is boosting pressure, NOT total system pressure.

PAGE 4

10

CentriPro
Residential and Commercial Water Systems
(114.30)
4.50

AQUAVAR ABII CONTROLLER FEATURES
(8.38)
.33

(57.15)
Power*
— 208-230V
2.25

Input
(controller only)

1AB2
2AB2

±15%, single phase

(114.30)
4.50

(135.36)
5.33

(57.15)
2.25

(8.38)
.33

Output Power — Up to 230V three phase (based on
input voltage). Motor rated for 208-230V, ±10%.
Maximum Output Current	 —	 4.2 amps – 1AB2 (1 HP)
	
—	 6.9 amps – 2AB2 (2 HP)
(242.04)
9.53

Input Controls — Up and down buttons to set pressure.
(259.08)

(237.06)
9.33

10.20

(232.56)
9.16

Signal Lights — Power on, pump running, inverter
stopped, pump stopped, standby, faults/errors.

(114.30)
(242.04)
4.50 9.53

Electrical Efficiency — Over 95% at full load

(8.38)
.33

Protection Against — Short circuit, under voltage, overload, motor temperature, dead heading, run out, suction loss, sensor fault, bound pump,
over voltage, static
(16.51)
discharge. Note: Suction loss/run.65
out is set for minimum
(12.07)
10 psi at discharge!
.48
(81.28)
3.20

(25
10

(232.56)
9.16

(135
5.3

(57.15)
2.25

(16.51)
.65

(157.90)
6.22

Ambient Temperature — 34º F to 104º F

(81.28)
3.20
(259.08)
10.20

Maximum Humidity — 95% at 104º F, non-condensing
(242.04)
9.53

(232.56)
9.16

(237.06)
9.33

Air Pollution — Avoid mounting in areas with excessive
dust, acids, corrosives and salts.
Approvals —

C

UL
®

US

(114.30)
4.50

Tested to UL 778 and
CSA 22.2 108 Standards
By Canadian Standards
Association
File #LR38549

(Listing on Controller Only)

Controller Enclosure — Outdoor, NEMA
3R, IP 43
(8.38)
.33
(Rain-tight)

(135.36)
5.33

(57.15)
2.25

(16.51)
.65

Mounting — Wall mount with mounting hardware.
Cooling	—	 Convection with cast aluminum heat sink.
	
—	 3 HP, 5 HP with temperature fan

(12.07)
.48

(81.28)
3.20

Transducer — 0.5 - 4.5 VDC with 5 VDC power supply,
100 psi range, 10-foot 3-wire shielded(242.04)
cable.(232.56)
9.53

(99.06)
3.90

9.16

(157.90
6.22

(237.06)
9.33

(259.08)
10.20

Input Wire — 5 feet of 14, 10 or 8 gauge cable. Depending on size, cable is pre-wired to controller and motor
conduit box.
Output Wire — 10 feet of 14 gauge cable. Cable is prewired to controller and pump motor (when provided).

(16.51)
.65

*Low input voltage may affect motor operation.
(81.28)
3.20

½"
Liquid
Tight

(12.07)
.48
(157.90)
6.22

PRESSURE RANGE
(99.06)
3.90

Nominal Range — Field adjustable from 20 - 85 psi, total system pressure.

WARNING DO NOT SET REQUIRED SYSTEM PRESSURE ABOVE 85 PSI. SEVERE DAMAGE TO PLUMBING COULD RESULT. PLUMB RELIEF VALVE OUTSIDE OR TO A DRAIN.

PAGE 5

CentriPro
Residential and Commercial Water Systems
SUGGESTED AB2 INSTALLATION FOR MUNICIPAL WATER SYSTEM
Home Supply

Water Main
Check Valve
Isolation Valves

AquaBoost
Controller

Circuit
Breaker

Unions
Transducer
Gauge
Relief
Tank
Valve

Disconnect

Check Valve

Figure 1

To Drain

Motor/Pump

SUGGESTED AQUABOOST INSTALLATION FOR WELL PUMP SYSTEM
Well Supply

Home Supply
Check Valve
Isolation Valves

AquaBoost
Controller

Circuit
Breaker
Disconnect

Unions
Transducer
Gauge
Relief
Tank
Valve
Check Valve

Figure 2
PAGE 6

To Drain
Motor/Pump

Isolation
Valve

Atmospheric
Storage Tank

CentriPro
Residential and Commercial Water Systems

Model MCC / 1MC Size 1 x 1¼-6

METERS FEET 1MC1F2B0, 1MC1G1A0 VARIABLE SPEED

Performance Range at 0 Suction, Max. Imp. Dia. 61/8"

150
140
40

1MC1G2A0

130

TOTAL DYNAMIC HEAD H

120

MAX.
(61/8")

1MC1F2B0

110
100

30

90
80
70

20

60
50
40

10

30

Indicates
1MC1F2B0
pump with
5¾” diameter
impeller.

MIN

20
10
0

0

5

0
1

0

15

10
2

3

20

25

4

30

7 m3/hr

6

5

CAPACITY

U.S. GPM

METERS PSI FEET
80

TOTAL DYNAMIC HEAD (H)

50

Model LB / Size 1 x 1¼
LB1035 VARIABLE SPEED
Performance Range at 0 Suction
Impeller Diameter 5¼"

180

70

160

60

140

40
50
30

MAX

120
100

40
80

20

30
60

NOTE:
Operation
beyond
pictured range,
may overload
controller and
cause
shutdown.

20
40

10
10

0

0

MIN

20
0

0
0

2

4

6
1

10

8
2

12

14
3

CAPACITY (Q)

18

16
4

22 U.S. GPM

20
5

m3/hr

PAGE 7

CentriPro
Residential and Commercial Water Systems
FEET
300

60

2HMS
TOTAL DYNAMIC HEAD

80
70
60
50
40

250

20
10
0

200

80
70

150

3

60
50

30

1HM1E2D0, 2HM1E2D0
and 2HM1F2E0
Performance Range
at 0 Suction

100
90

40

100

1
2

30
20

50

10
0

0

0
0

10

5
1

2

20

15
3

4

➀ Curve represents pump model 1HM1E2D0.
➁ Curve represents pump model 2HM1E2DO.
➂ Curve represents pump model 2HM1F2E0.

30

25
5

CAPACITY

PAGE 8

40

1HMS

6

35
7

8

40 US GPM
9 m3/ hr 10

20

EFF. %

PSI

90

MAXIMUM SPEED

METERS

CentriPro
Residential and Commercial Water Systems

TOTAL DYNAMIC HEAD (TDH)

FEET

LC Stainless Steel Variable Speed
Constant Pressure System
MODEL: 3AB2LCB1H2D0
2 STAGE PUMP
5.19" DIAM. IMP.

3550 RPM

210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0

3150
EFF.
52.2%
2625

1775

0

4

8

12

16

20

24

28

32

36

40

44

48

62

56

60 US GPM

CAPACITY

TOTAL DYNAMIC HEAD (TDH)

FEET

MCC Cast Iron / SS Variable Speed
Constant Pressure System
MODEL: 2AB22MC1G2D2
SINGLE STAGE PUMP
4.62" DIAM. IMP.

3550 RPM

92
88
84
80
76
72
68
64
60
56
52
48
44
40
36
32
28
24
20
16
12
8
4

3150

EFF.
60.4%

2625

1775

0

5

10 15 20 25 30 35 40 45 50 55 60 65 70 75 80 85 90 95 100 105 110 115 US GPM

CAPACITY

NOTE: Curves indicate boost pressure.

PAGE 9

CentriPro
Residential and Commercial Water Systems

FEET

MCC Cast Iron / SS Variable Speed
Constant Pressure System
MODEL: 5AB22MC1J2K2
SINGLE STAGE PUMP
6.12" DIAM. IMP.

3550 RPM

140

TOTAL DYNAMIC HEAD (TDH)

130
120

EFF.

3150

110

59.3%

100
90

2625

80
70
60
50
40

1775

30
20
10
0

10

20

30

40

50

60

70

80

90

100

110

120

130

US GPM

CAPACITY

HEAD

FEET

LC Stainless Steel Variable Speed
Constant Pressure System
MODEL: 5AB2LCC1J2D0
2 STAGE PUMP
5.19" DIAM. IMP.

3550 RPM

210
200
190
180
170
160
150
140
130
120
110
100
90
80
70
60
50
40
30
20
10
0

3150

EFF.
52.7%

2625

1775

0

5

10

15

20

25

30

35

40

45

50

55

60

CAPACITY

NOTE: Curves indicate boost pressure.

PAGE 10

65

70

75

80

85

90

95 100

US GPM

CentriPro
Residential and Commercial Water Systems
DIMENSIONS (For Reference Only - Do not use for construction purposes)
LB PUMP (LB1035) WITH TANK AND TEE
Capacities	 —	

Pipe Connections — 1 x 11⁄4 NPT

to 15 GPM	

Rotation	 —	 Right hand clockwise, 	
Maximum Temperature of Water — 120º F
		
viewed from motor end	
NOTE:	Tank Liquid Temperature Limit is 120º F
				
Pump Liquid Temperature Limit is 140º F
Materials	 —	
		

304 stainless steel casing 	
Noryl impeller

Maximum System Working Pressure — 85 psi

Motor	
—	
		

1 HP, ODP, Three Phase, 	
208-230/460V

Seal — Carbon / Silicon Carbide / EPR

Overload protection, starters, heaters not required.
Dimensions are in inches.

2.78

14.93

PRESSURE GAUGE
PORT ¼" NPT

½" NPT PLUG

V6P TANK
¾" NPT

TRANSDUCER
PORT ¼" NPT

DISCHARGE
1” NPT MALE
¾” NPT FEMALE

➀
18.43

SUCTION
1¼” NPT
FEMALE

½ - 14 NPSM CONDUIT
CONNECTION ODP MOTORS
14.31

8.75

6.31Ø

6.50
4.25
REF

1.00
8.09

.10 (12 GA)
7.00

6.75

Approximate Packaged Shipping Weight — 55 lbs.
➀ Add the Check Valve dimension to this Reference Dimension

PAGE 11

CentriPro
Residential and Commercial Water Systems
DIMENSIONS (For Reference Only - Do not use for construction purposes)
MCC PUMP (1MC1G2A2 AND 1MC1F2B2) WITH TANK AND TEE
Capacity	 —	 to 32 GPM (1MC1G2A2)	
Pipe Connections — 1 x 11⁄4 NPT
	
—	 to 27 GPM (1MC1F2B2)		
Rotation	 —	 Right hand clockwise, 	
Maximum Temperature of Water — 120º F
		 viewed from motor end	
NOTE:	Tank Liquid Temperature Limit is 120º F
				
Pump Liquid Temperature Limit is 212º F
Materials	 —	 Cast iron casing 	
		 316 stainless steel impeller

Maximum System Working Pressure — 85 psi

Motor	
	

Seal — Carbon / Silicon Carbide / EPR

—	11⁄2 HP, ODP, Three Phase, 208-230/460V	
—	 2 HP, ODP, Three Phase, 208-230/460V

Overload protection, starters, heaters not required.
Dimensions are in inches.

½" NPT PLUG

PRESSURE GAUGE
PORT ¼" NPT

2.00

V6P TANK
¾" NPT

TRANSDUCER
PORT ¼" NPT

DISCHARGE
1” NPT MALE
¾” NPT FEMALE

➀
12.22
19.87

6.25

½ - 14 NPSM CONDUIT
CONNECTION ODP MOTORS

SUCTION
1¼” NPT
FEMALE
15.75

6.31Ø

4.50

¼" NPT
DRAIN PLUG
6.75

Approximate Packaged Shipping Weight — 75 lbs.
➀ Add the Check Valve dimension to this Reference Dimension

PAGE 12

.75
4.58

.10 (12 GA)
6.75

4 SLOTS LENGTHWISE
.34 X .50 LONG

CentriPro
Residential and Commercial Water Systems
DIMENSIONS (For Reference Only - Do not use for construction purposes)
HMS PUMPS (1HM1E2D0, 2HM1E2D0)
Capacities	—	 to 20 GPM (1HM)	
to 38 GPM (2HM4/2HM5)
		
	

Pipe Connections — 1 x 11⁄4 NPT

Materials	 —	 316L stainless steel for all liquid	
handling components
		
	

Maximum System Working Pressure — 85 psi

Maximum Temperature of Water — 120º F
NOTE:	Tank Liquid Temperature Limit is 120º F
Rotation	 —	 Right hand clockwise, 	
Pump Liquid Temperature Limit is 212º F
		 viewed from motor end		

Motor	
	

Seal — Carbon / Silicon Carbide / EPR

—	 1 HP, ODP, Three Phase,208-230/460V (1HM/2HM4)
—	 1.5 HP, ODP, Three Phase,208-230/460V (2HMS5)

Overload protection, starters, heaters not required. Dimensions are in inches.

A

3.19

C
PRESSURE GAUGE
PORT ¼" NPT
V6P TANK
¾" NPT

½" NPT
PLUG

TRANSDUCER
PORT ¼" NPT

16.75
MAX

1" NPT

➀

DISCHARGE
1” NPT MALE
¾” NPT FEMALE
FILL PLUG

12.12
± .50
2.19
6.53
MAX
4.94

4.12

5.50

L
1¼" NPT
SUCTION

6.75

4.94
7.25

½ - 14 NPSM
CONDUIT
CONNECTION
ODP MOTORS
4 SLOTS LENGTHWISE
.34 X .72 ON CENTER

DRAIN PLUG

	AQUABOOST	

A	

L	

	 1AB22HM1E2D0	
	 1AB21HM1E2D0	
	 2AB22HM1F2E0	

5.75	
5.75	
6.73	

10.75	
10.75	
11.75	

C	 MOUNTING
11.62	
11.12	
11.62	

View B
View A
View B

Approximate Packaged Shipping Weight — 55 lbs.
➀ Add the Check Valve dimension to this Reference Dimension
PAGE 13

CentriPro
Residential and Commercial Water Systems
ALTERNATE PUMP MODELS FOR USE WITH 1AB2 CONTROLLER
MCC — 1⁄2, 3⁄4, 1 HP, 3 ph, ODP or TEFC motor versions
3642 — 1⁄3, 1⁄2, 1 HP, 3 ph, ODP or TEFC motor versions
GT073, GT103 — 3 ph, ODP or TEFC motor versions
HSC07, HSC10 — 3 ph, ODP or TEFC motor versions
HMS — 1⁄2, 3⁄4, 1 HP, 3 ph, ODP or TEFC motor versions
5GB, 7GB — 1⁄2, 3⁄4, 1 HP, 3 ph, ODP or TEFC motor versions
NPE — 1⁄2, 3⁄4, 1 HP, 3 ph, ODP or TEFC motor versions
NPO — 1⁄2, 3⁄4, 1 HP, 3 ph, ODP or TEFC motor versions
MCS — 1⁄2, 3⁄4, 1 HP, 3 ph, ODP or TEFC motor versions
ICS — 1⁄2, 3⁄4, 1 HP, 3 ph, ODP or TEFC motor versions
LB — 1⁄2 and 3⁄4 HP, 3 ph, ODP or TEFC motor versions

Note: These pumps are not currently
offered as a packaged kit, from CentriPro.
All units require three phase motors.
Size pumps and controllers according to
service factor amps of the motor.

ALTERNATE PUMP MODELS FOR USE WITH 2AB2 CONTROLLER
3642 — 11⁄2, 2 HP, 3 ph, ODP or TEFC motor versions
GT — 11⁄2, 2 HP, 3 ph, ODP or TEFC motor versions
HSC — 11⁄2, 2 HP, 3 ph, ODP or TEFC motor versions
HMS — 11⁄2 HP, 3 ph, ODP or TEFC motor versions
10GB — 11⁄2, 2 HP, 3 ph, ODP or TEFC motor versions
NPE — 11⁄2, 2 HP, 3 ph, ODP or TEFC motor versions
NPO — 11⁄2, 2 HP, 3 ph, ODP or TEFC motor versions
MCS — 11⁄2, 2 HP, 3 ph, ODP or TEFC motor versions

Note: These pumps are not currently
offered as a packaged kit, from CentriPro.
All units require three phase motors.
Size pumps and controllers according to
service factor amps of the motor.

ICS — 11⁄2, 2 HP, 3 ph, ODP or TEFC motor versions

SUBMERSIBLE PUMPS
Use Aquavar SOLO or S-Drive controllers for submersible applications,
they have filters built-in and are programmed for submersibles.

PAGE 14

CentriPro
Residential and Commercial Water Systems
PACKAGED HARDWARE WITHOUT PUMP AND MOTOR (SEE PRICING PAGE)
Part Number 15K40
KIT INCLUDES:
1)
2)
3)
4)

Tank – V6P (2 gallons)
1" Bronze Discharge Tee – AV20-6
Pipe Plug – 1⁄2", 6K68
Pressure Gauge – AG5 (1 – 100 PSI)

PAGE 15

Xylem
1) The tissue in plants that brings water upward from the roots;
2) a leading global water technology company.
We’re 12,500 people unified in a common purpose: creating innovative solutions
to meet our world’s water needs. Developing new technologies that will improve
the way water is used, conserved, and re-used in the future is central to our work.
We move, treat, analyze, and return water to the environment, and we help people
use water efficiently, in their homes, buildings, factories and farms. In more than
150 countries, we have strong, long-standing relationships with customers who
know us for our powerful combination of leading product brands and applications
expertise, backed by a legacy of innovation.
For more information on how Xylem can help you, go to www.xyleminc.com

Xylem, Inc.
2881 East Bayard Street Ext., Suite A
Seneca Falls, NY 13148
Phone: (866) 325-4210
Fax: (888) 322-5877
www.xyleminc.com/brands/centripro
CentriPro and AquaBoost are trademarks of Xylem Inc. or one of its subsidiaries.
© 2012 Xylem Inc.

BAQUABII R2

January 2013



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : No
Create Date                     : 2013:01:30 10:13:41-05:00
Creator                         : Adobe InDesign CS5 (7.0)
Modify Date                     : 2015:03:10 13:22:53-04:00
Trapped                         : False
Tagged PDF                      : Yes
XMP Toolkit                     : 3.1-701
Producer                        : Adobe PDF Library 9.9
Creator Tool                    : Adobe InDesign CS5 (7.0)
Page Count                      : 16
EXIF Metadata provided by EXIF.tools

Navigation menu