540223 2 Centripro SES D10020 D32232 Duplex Control Panel Technical Brochure

540214 1 Centripro Duplex Control Panel Brochure 540214_1_Centripro Duplex Control Panel Brochure

540215 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540215_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure

540218 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540218_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure

540219 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540219_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure

540220 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540220_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure

: Pump 540223 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540223_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure pdf

Open the PDF directly: View PDF PDF.
Page Count: 8

Download540223 2 Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure
Open PDF In BrowserView PDF
TECHNICAL BROCHURE
BCP4 R13

FEATURES
NEMA 4X, 30 watt, flashing red light and alarm horn ­– 95db.
NEMA 4X, fiberglass enclosure with gasketed, hinged door
and stainless steel hardware.
Entire unit is UL and CUL listed.
Single Phase
Field adjustable for 115, 208 or 230V, 60 Hz.
2 pump circuit breakers.
Three Phase
Field adjustable for 208/230 /460/575V, 60 Hz.
115V control circuit transformer.
2 adjustable motor overload protectors.
Heaters not required.
Provides fully automatic operation for two pumps.
Solid state pump alternator circuit displays float status for
ease of installation and trouble shooting.

DUPLEX NEMA 4X
WEATHERPROOF PANELS
SINGLE AND THREE PHASE CONTROL PANELS

CentriPro
Wastewater
APPLICATIONS
Superior quality duplex liquid-level controller, automatically controls alternation for two pump operation.
High-level alarm warning designed for a variety of
sump, effluent, sewage and water transfer applications.
SPECIFICATIONS

• Accepts single or dual power feed.
• 2 hand-off-automatic (H-O-A) pump switches.
• On-off control circuit switch.

• Hinged door with lockable stainless steel latch for
safe operation indoors or out.

• High-level alarm circuit includes through-door

mounted silence switch for manual silence of alarm
horn.

• Through-door mounted alarm test switch insures
proper operation of the alarm circuit without the
need to open the panel.

• Two through-door mounted pump run lights.
• Top-mounted high intensity flashing red light provides 360° visibility.

• 2 oversized magnetic contactors.

• Pulsating, corrosion proof alarm horn.

• Numbered terminal strip-screw type.

• These duplex controls are factory wired for opera-

• Float Switches – Note: Please order float switches

separately. We offer several types and models. See
the Float Switch bulletin for available options. The
type selected determines the quantity needed.
The basin depth and panel location determine the
required cord length. Contact your distributor or
Customer Service for additional information.

• Electronic pump alternator.
• Alternator selector switch.
• Lag pump start delay.
FEATURES

• Rugged, NEMA 4X construction withstands even the

most severe weather conditions and prevents corrosion.

• Provides fully automatic operation for two pumps.
Alternates pump starting to distribute operating
time. Provides extra pumping capacity in times of
high inflow by energizing both pumps.

• Alternator selector toggle for maintenance on one
or both pumps.

tion with three float bulbs. An easy field modification
for four float bulb operation using separate “lag-on”
and “alarm bulbs” is provided.

• Alternator selector switch allows a choice of automatic alternation or operation of only pump 1 or
pump 2. Typically used if one pump is down for
maintenance.

• Lag pump-start delay built-in. Delays starting lag

pump for 5 seconds if both pumps attempt to start
simultaneously as after a power outage.

• Panel can be wired for a single power feed for

pumps and control circuit or the control circuit can
be wired to a separate power supply to insure alarm
integrity in case of a tripped main breaker.

• Auxiliary alarm contacts provided for remote alarm
connection.

• Color coded wiring, screw type terminals and plug
in sockets, ensure ease of field servicing.

• Field wiring diagram, panel schematic and installation instructions included.

• Requires three float switches or with optional fourth
lag float, order separately.

PANEL MODEL INFORMATION
	
SINGLE PHASE PANELS 	
	
ORDER NUMBER 	
AMP / HP RANGE	
	
D10020	
0-20 AMPS	
	
D12127	
3 HP	
	
D12836	
5 HP	
			
			
			
			
			
PAGE 2

THREE PHASE PANELS
ORDER NUMBER 	
AMP RANGE
D31625	
1.6 - 2.5
D32540	
2.5 - 4.0
D34063	
4.0 - 6.3
D36310	
6.3 - 10
D31016	
10 - 16
D31620	
16 - 20
D32025	
20 - 25
D32232	
22 - 32

CentriPro
Wastewater
ADDITIONAL OPTIONS
Code (add as required)

P	 =	 Special duplex Mini CAS seal fail and high
		 temperature circuit for use on only three phase
		 15/20GD, 15/20GX, 1GA/2GA, GV Plus and
		 Impact pumps. For single phase, see CentriPro
		 single phase grinder control panels bulletin
		 BCP1PGP for standard, BCP1PC1P for explosion
		 proof.

A	 =	 Guaranteed pump submergence circuit
C	 =	 115V condensation heater
D	 =	 Single phase lightning arrestor
E	 =	 Three phase lightning arrestor
G	 =	 Elapsed time meter (2) – Duplex

T	 =	 4 intrinsically safe relays in duplex panel

J	 =	 Seal fail circuit (2) – Duplex
L	 =	 Cycle counter (2) – Duplex

YY	=	 Duplex dry contact for seal failure interface to
		 building management system.

N	 =	 High temp. indicator with pump shutdown –
		 Duplex

ZZ	=	 Duplex dry contact for pump running interface to
		 building management system.
When ordering options, add the appropriate code
number as a suffix to the panel order number.
Example...D31625CG adds a condensation heater
and (2) elapsed time meters.

ENCLOSURE DIMENSIONS (in inches)
Single Phase
A	B	 C	D	 E	 F	 G
10.1	
15.5	
18.3	
14.8	
6.8	
7.2	
13.3

	
	

Three Phase
	
A	B	 C	D	 E	 F	 G
	 12.1	
17.5	
20.3	
16.8	
6.8	
7.2	
15.3
NOTE: Mounting holes are 3⁄8".

C

B

D

A
G

E

F

PAGE 3

CentriPro
Wastewater
SINGLE PHASE COMPONENTS

THREE PHASE COMPONENTS

1.	 NEMA 4X enclosure
2.	 Flashing alarm light
3.	 Alarm horn
4.	 Pump run light
5.	 Alarm silence button
6.	 Alarm test button
7.	 Control power on/off switch
8.	 H-O-A switch
9.	 Alarm reset button
10. Contactor
11. Terminal strip
12. Alternator circuit
13. Motor circuit breakers

1.	 NEMA 4X enclosure
2.	 Flashing alarm light
3.	 Alarm horn
4.	 Pump run light
5.	 Alarm silence button
6.	 Alarm test button
7.	 Control power on/off switch
8.	 H-O-A switch
9. Alarm reset button
10. Contactor
11. Terminal strip
12. Alternator circuit
13. Control transformer
14. Motor circuit protectors

2

2

7, 8

13

7, 8

14

13
4

6

4

9

10

5

12

4

6

11

1

PAGE 4

10

3

10

4

9

5

10

11

1

3

12

CentriPro
Wastewater
DUPLEX SINGLE PHASE WIRING DIAGRAM – D10020
NOTE: The standard panels shown in this book are not designed to be used with pumps requiring external
capacitors. See the catalog for panels with built-in capacitor packs.
25 A

S1
1

FOR 120 VOLT OPERATION
USE TERMINALS (L1) AND (N)
JUMP TERMINALS (N) AND (L2)

2
S2

25 A
L1

230 VAC
SINGLE PHASE
60 Hz

PUMP NO. 1

1T

1
2T

PUMP NO. 2
2

L2

WHITE

N
GND
CONTROL
ON-OFF

RUN

A 230 VOLT SYSTEM
REQUIRES A 4-WIRE
POWER SUPPLY LINE
L1, L2, N AND GND.
WITHOUT A NEUTRAL
THE CONTROL CIRCUIT
WILL NOT WORK.

BLACK

HAND
OFF PURPLE
YELLOW

S1

AUTO

RUN
BLACK

HAND
OFF BLUE
ORANGE

ALTERNATOR SWITCH –
STANDARD ON ALL DUPLEX
PANELS, THIS SWITCH
PROVIDES OPTIONS FOR:
ALTERNATE PUMPS, USE
ONLY PUMP 1 OR USE ONLY
PUMP 2. IT IS USED WHEN A
PUMP IS REMOVED FOR
SERVICE.

RED
ALTERNATOR SWITCH
PUMP 1
ALT
PUMP 2

R1

FOR SEPARATE 120 VAC
CONTROL POWER SUPPLY,
REMOVE JUMPER (J1) FROM
TERMINALS (H) AND (L1).
CONNECT 15 AMP MAX.
PROTECTED 120 VAC SUPPLY
TO TERMINALS (L1) AND (N).
WITH THE NEUTRAL OF THE
SUPPLY TO (N).
FOR USE WITH WIDE
ANGLE FLOAT SWITCH (ONE
FLOAT FOR BOTH ON AND
OFF OPERATION). JUMP
TERMINALS (3) AND (4),
INSTALL WIDE ANGLE FLOAT
TO TERMINALS (1) AND (2).

S2

AUTO

TEST
TEST

SILENCE

R2

MUTE

C

RESET
OFF

LEAD

LAG

ALARM
FLASHING

L1

N
H

L1

N

SONALERT
1

2

3

4

5

RED

6

7

8

9

10

YEL
YELLOW
RESET
BRW
BROWN

RED
PINK
WHITE

FLASH

HORN

11

BLACK
DRY CONTACTS

J1

FACTORY WIRED FOR (3) FLOAT
OPERATION. FOR (4) FLOAT
OPERATION, REMOVE JUMPER (J2)
FROM TERMINALS (6) AND (8). INSTALL
LAG FLOAT ON TERMINALS (5) AND (6).

J2
ALARM FLOAT
LAG FLOAT
(OPTIONAL)
LEAD FLOAT
OFF FLOAT

PAGE 5

CentriPro
Wastewater
DUPLEX THREE PHASE WIRING DIAGRAM – D3 — — — —
S1
1
1
T

PUMP
NO. 1

2
3

S2
1
2

L2

2A

208 VAC

230 VAC

L3

460 VAC

T
575 VAC

208/230/460/575 VAC
THREE PHASE
60 Hz

L1

75 VA

PUMP
NO. 2

2
3

FACTORY WIRED FOR 460 VAC. FOR 208, 230 OR
FOR 575 VAC OPERATION CHANGE CONTROL
TRANSFORMER PRIMARY AT TERMINCAL BLOCK.

WHITE

120 VAC
CONTROL
ON-OFF

ALTERNATOR SWITCH –
STANDARD ON ALL DUPLEX
PANELS, THIS SWITCH
PROVIDES OPTIONS FOR:
ALTERNATE PUMPS, USE
ONLY PUMP 1 OR USE ONLY
PUMP 2. IT IS USED WHEN
A PUMP IS REMOVED FOR
SERVICE.

OFF PURPLE
YELLOW

RUN
HAND
OFF BLUE

S2

ORANGE
AUTO

RED
TEST

ALTERNATOR SWITCH
PUMP 1
ALT
PUMP 2

R1

FOR USE WITH WIDE
ANGLE FLOAT SWITCH (ONE
FLOAT FOR BOTH ON AND
OFF OPERATION). JUMP
TERMINALS (3) AND (4),
INSTALL WIDE ANGLE FLOAT
TO TERMINALS (1) AND (2).

TEST

R2

MUTE

C

RESET
OFF

LEAD

LAG

ALARM
FLASHING

L1

N
H

L1

N

SONALERT
1

2

3

4

5

6

7

8

9

10

11

BLACK
DRY CONTACTS
J2
ALARM FLOAT
LAG FLOAT
(OPTIONAL)
LEAD FLOAT
OFF FLOAT

RED
SILENCE

J1

PAGE 6

S1

AUTO

BLACK

FOR SEPARATE 120 VAC
CONTROL POWER SUPPLY,
REMOVE JUMPER (J1) FROM
TERMINALS (H) AND (L1).
CONNECT 15 AMP MAX.
PROTECTED 120 VAC SUPPLY
TO TERMINALS (L1) AND (N).
WITH THE NEUTRAL OF THE
SUPPLY TO (N).

FACTORY WIRED FOR (3)
FLOATOPERATION. FOR (4)
FLOATOPERATION, REMOVE
JUMPER (J2) FROM TERMINALS
(6) AND (8). INSTALLLAG
FLOAT ON TERMINALS (5)
AND (6).

RUN
HAND

BLACK

YEL
YELLOW
RESET
BRW
BROWN

RED
PINK
WHITE

FLASH

HORN

CentriPro
Wastewater
NOTES

PAGE 7

Xylem
1) The tissue in plants that brings water upward from the roots;
2) a leading global water technology company.
We’re a global team unified in a common purpose: creating innovative solutions to
meet our world’s water needs. Developing new technologies that will improve the
way water is used, conserved, and re-used in the future is central to our work. We
move, treat, analyze, and return water to the environment, and we help people use
water efficiently, in their homes, buildings, factories and farms. In more than 150
countries, we have strong, long-standing relationships with customers who know us
for our powerful combination of leading product brands and applications expertise,
backed by a legacy of innovation.
For more information on how Xylem can help you, go to www.xyleminc.com

Xylem Inc.
2881 East Bayard Street Ext., Suite A
Seneca Falls, NY 13148
Phone: (866) 325-4210
Fax: (888) 322-5877
www.centripro.com
CentriPro is a trademark of Xylem Inc. or one of its subsidiaries.
© 2015 Xylem Inc. BCP4 R13 September 2015



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27
Create Date                     : 2015:09:10 08:47:29-04:00
Metadata Date                   : 2015:09:10 08:47:41-04:00
Modify Date                     : 2015:09:10 08:47:41-04:00
Creator Tool                    : Adobe InDesign CS6 (Macintosh)
Instance ID                     : uuid:c9e374ad-3855-fb45-8182-110fdb8660a7
Original Document ID            : adobe:docid:indd:6116ff89-6a83-11db-bbf7-c0c80c6d23ec
Document ID                     : xmp.id:F77F1174072068118A6DB7D0DB740F2B
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:5CAB0EEC0B2068118083C46F7BEC4583
Derived From Document ID        : xmp.did:69662C400B2068118083C46F7BEC4583
Derived From Original Document ID: adobe:docid:indd:6116ff89-6a83-11db-bbf7-c0c80c6d23ec
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Macintosh)
History Changed                 : /
History When                    : 2015:09:10 08:47:30-04:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Postscript Name                 : AvenirNextLTPro-Bold, AvenirNextLTPro-Medium, AvenirNextLTPro-Regular
Profile Blob                    : 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, 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, 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
Page Count                      : 8
Creator                         : Adobe InDesign CS6 (Macintosh)
EXIF Metadata provided by EXIF.tools

Navigation menu