540223 2 Centripro SES D10020 D32232 Duplex Control Panel Technical Brochure
540214 1 Centripro Duplex Control Panel Brochure 540214_1_Centripro Duplex Control Panel Brochure
540215 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540215_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure
540218 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540218_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure
540219 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540219_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure
540220 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540220_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure
: Pump 540223 2 Centripro Ses D10020-D32232 Duplex Control Panel Technical Brochure 540223_2_Centripro SES D10020-D32232 Duplex Control Panel Technical Brochure pdf
Open the PDF directly: View PDF
.
Page Count: 8
| Download | |
| Open PDF In Browser | View PDF |
TECHNICAL BROCHURE BCP4 R13 FEATURES NEMA 4X, 30 watt, flashing red light and alarm horn – 95db. NEMA 4X, fiberglass enclosure with gasketed, hinged door and stainless steel hardware. Entire unit is UL and CUL listed. Single Phase Field adjustable for 115, 208 or 230V, 60 Hz. 2 pump circuit breakers. Three Phase Field adjustable for 208/230 /460/575V, 60 Hz. 115V control circuit transformer. 2 adjustable motor overload protectors. Heaters not required. Provides fully automatic operation for two pumps. Solid state pump alternator circuit displays float status for ease of installation and trouble shooting. DUPLEX NEMA 4X WEATHERPROOF PANELS SINGLE AND THREE PHASE CONTROL PANELS CentriPro Wastewater APPLICATIONS Superior quality duplex liquid-level controller, automatically controls alternation for two pump operation. High-level alarm warning designed for a variety of sump, effluent, sewage and water transfer applications. SPECIFICATIONS • Accepts single or dual power feed. • 2 hand-off-automatic (H-O-A) pump switches. • On-off control circuit switch. • Hinged door with lockable stainless steel latch for safe operation indoors or out. • High-level alarm circuit includes through-door mounted silence switch for manual silence of alarm horn. • Through-door mounted alarm test switch insures proper operation of the alarm circuit without the need to open the panel. • Two through-door mounted pump run lights. • Top-mounted high intensity flashing red light provides 360° visibility. • 2 oversized magnetic contactors. • Pulsating, corrosion proof alarm horn. • Numbered terminal strip-screw type. • These duplex controls are factory wired for opera- • Float Switches – Note: Please order float switches separately. We offer several types and models. See the Float Switch bulletin for available options. The type selected determines the quantity needed. The basin depth and panel location determine the required cord length. Contact your distributor or Customer Service for additional information. • Electronic pump alternator. • Alternator selector switch. • Lag pump start delay. FEATURES • Rugged, NEMA 4X construction withstands even the most severe weather conditions and prevents corrosion. • Provides fully automatic operation for two pumps. Alternates pump starting to distribute operating time. Provides extra pumping capacity in times of high inflow by energizing both pumps. • Alternator selector toggle for maintenance on one or both pumps. tion with three float bulbs. An easy field modification for four float bulb operation using separate “lag-on” and “alarm bulbs” is provided. • Alternator selector switch allows a choice of automatic alternation or operation of only pump 1 or pump 2. Typically used if one pump is down for maintenance. • Lag pump-start delay built-in. Delays starting lag pump for 5 seconds if both pumps attempt to start simultaneously as after a power outage. • Panel can be wired for a single power feed for pumps and control circuit or the control circuit can be wired to a separate power supply to insure alarm integrity in case of a tripped main breaker. • Auxiliary alarm contacts provided for remote alarm connection. • Color coded wiring, screw type terminals and plug in sockets, ensure ease of field servicing. • Field wiring diagram, panel schematic and installation instructions included. • Requires three float switches or with optional fourth lag float, order separately. PANEL MODEL INFORMATION SINGLE PHASE PANELS ORDER NUMBER AMP / HP RANGE D10020 0-20 AMPS D12127 3 HP D12836 5 HP PAGE 2 THREE PHASE PANELS ORDER NUMBER AMP RANGE D31625 1.6 - 2.5 D32540 2.5 - 4.0 D34063 4.0 - 6.3 D36310 6.3 - 10 D31016 10 - 16 D31620 16 - 20 D32025 20 - 25 D32232 22 - 32 CentriPro Wastewater ADDITIONAL OPTIONS Code (add as required) P = Special duplex Mini CAS seal fail and high temperature circuit for use on only three phase 15/20GD, 15/20GX, 1GA/2GA, GV Plus and Impact pumps. For single phase, see CentriPro single phase grinder control panels bulletin BCP1PGP for standard, BCP1PC1P for explosion proof. A = Guaranteed pump submergence circuit C = 115V condensation heater D = Single phase lightning arrestor E = Three phase lightning arrestor G = Elapsed time meter (2) – Duplex T = 4 intrinsically safe relays in duplex panel J = Seal fail circuit (2) – Duplex L = Cycle counter (2) – Duplex YY = Duplex dry contact for seal failure interface to building management system. N = High temp. indicator with pump shutdown – Duplex ZZ = Duplex dry contact for pump running interface to building management system. When ordering options, add the appropriate code number as a suffix to the panel order number. Example...D31625CG adds a condensation heater and (2) elapsed time meters. ENCLOSURE DIMENSIONS (in inches) Single Phase A B C D E F G 10.1 15.5 18.3 14.8 6.8 7.2 13.3 Three Phase A B C D E F G 12.1 17.5 20.3 16.8 6.8 7.2 15.3 NOTE: Mounting holes are 3⁄8". C B D A G E F PAGE 3 CentriPro Wastewater SINGLE PHASE COMPONENTS THREE PHASE COMPONENTS 1. NEMA 4X enclosure 2. Flashing alarm light 3. Alarm horn 4. Pump run light 5. Alarm silence button 6. Alarm test button 7. Control power on/off switch 8. H-O-A switch 9. Alarm reset button 10. Contactor 11. Terminal strip 12. Alternator circuit 13. Motor circuit breakers 1. NEMA 4X enclosure 2. Flashing alarm light 3. Alarm horn 4. Pump run light 5. Alarm silence button 6. Alarm test button 7. Control power on/off switch 8. H-O-A switch 9. Alarm reset button 10. Contactor 11. Terminal strip 12. Alternator circuit 13. Control transformer 14. Motor circuit protectors 2 2 7, 8 13 7, 8 14 13 4 6 4 9 10 5 12 4 6 11 1 PAGE 4 10 3 10 4 9 5 10 11 1 3 12 CentriPro Wastewater DUPLEX SINGLE PHASE WIRING DIAGRAM – D10020 NOTE: The standard panels shown in this book are not designed to be used with pumps requiring external capacitors. See the catalog for panels with built-in capacitor packs. 25 A S1 1 FOR 120 VOLT OPERATION USE TERMINALS (L1) AND (N) JUMP TERMINALS (N) AND (L2) 2 S2 25 A L1 230 VAC SINGLE PHASE 60 Hz PUMP NO. 1 1T 1 2T PUMP NO. 2 2 L2 WHITE N GND CONTROL ON-OFF RUN A 230 VOLT SYSTEM REQUIRES A 4-WIRE POWER SUPPLY LINE L1, L2, N AND GND. WITHOUT A NEUTRAL THE CONTROL CIRCUIT WILL NOT WORK. BLACK HAND OFF PURPLE YELLOW S1 AUTO RUN BLACK HAND OFF BLUE ORANGE ALTERNATOR SWITCH – STANDARD ON ALL DUPLEX PANELS, THIS SWITCH PROVIDES OPTIONS FOR: ALTERNATE PUMPS, USE ONLY PUMP 1 OR USE ONLY PUMP 2. IT IS USED WHEN A PUMP IS REMOVED FOR SERVICE. RED ALTERNATOR SWITCH PUMP 1 ALT PUMP 2 R1 FOR SEPARATE 120 VAC CONTROL POWER SUPPLY, REMOVE JUMPER (J1) FROM TERMINALS (H) AND (L1). CONNECT 15 AMP MAX. PROTECTED 120 VAC SUPPLY TO TERMINALS (L1) AND (N). WITH THE NEUTRAL OF THE SUPPLY TO (N). FOR USE WITH WIDE ANGLE FLOAT SWITCH (ONE FLOAT FOR BOTH ON AND OFF OPERATION). JUMP TERMINALS (3) AND (4), INSTALL WIDE ANGLE FLOAT TO TERMINALS (1) AND (2). S2 AUTO TEST TEST SILENCE R2 MUTE C RESET OFF LEAD LAG ALARM FLASHING L1 N H L1 N SONALERT 1 2 3 4 5 RED 6 7 8 9 10 YEL YELLOW RESET BRW BROWN RED PINK WHITE FLASH HORN 11 BLACK DRY CONTACTS J1 FACTORY WIRED FOR (3) FLOAT OPERATION. FOR (4) FLOAT OPERATION, REMOVE JUMPER (J2) FROM TERMINALS (6) AND (8). INSTALL LAG FLOAT ON TERMINALS (5) AND (6). J2 ALARM FLOAT LAG FLOAT (OPTIONAL) LEAD FLOAT OFF FLOAT PAGE 5 CentriPro Wastewater DUPLEX THREE PHASE WIRING DIAGRAM – D3 — — — — S1 1 1 T PUMP NO. 1 2 3 S2 1 2 L2 2A 208 VAC 230 VAC L3 460 VAC T 575 VAC 208/230/460/575 VAC THREE PHASE 60 Hz L1 75 VA PUMP NO. 2 2 3 FACTORY WIRED FOR 460 VAC. FOR 208, 230 OR FOR 575 VAC OPERATION CHANGE CONTROL TRANSFORMER PRIMARY AT TERMINCAL BLOCK. WHITE 120 VAC CONTROL ON-OFF ALTERNATOR SWITCH – STANDARD ON ALL DUPLEX PANELS, THIS SWITCH PROVIDES OPTIONS FOR: ALTERNATE PUMPS, USE ONLY PUMP 1 OR USE ONLY PUMP 2. IT IS USED WHEN A PUMP IS REMOVED FOR SERVICE. OFF PURPLE YELLOW RUN HAND OFF BLUE S2 ORANGE AUTO RED TEST ALTERNATOR SWITCH PUMP 1 ALT PUMP 2 R1 FOR USE WITH WIDE ANGLE FLOAT SWITCH (ONE FLOAT FOR BOTH ON AND OFF OPERATION). JUMP TERMINALS (3) AND (4), INSTALL WIDE ANGLE FLOAT TO TERMINALS (1) AND (2). TEST R2 MUTE C RESET OFF LEAD LAG ALARM FLASHING L1 N H L1 N SONALERT 1 2 3 4 5 6 7 8 9 10 11 BLACK DRY CONTACTS J2 ALARM FLOAT LAG FLOAT (OPTIONAL) LEAD FLOAT OFF FLOAT RED SILENCE J1 PAGE 6 S1 AUTO BLACK FOR SEPARATE 120 VAC CONTROL POWER SUPPLY, REMOVE JUMPER (J1) FROM TERMINALS (H) AND (L1). CONNECT 15 AMP MAX. PROTECTED 120 VAC SUPPLY TO TERMINALS (L1) AND (N). WITH THE NEUTRAL OF THE SUPPLY TO (N). FACTORY WIRED FOR (3) FLOATOPERATION. FOR (4) FLOATOPERATION, REMOVE JUMPER (J2) FROM TERMINALS (6) AND (8). INSTALLLAG FLOAT ON TERMINALS (5) AND (6). RUN HAND BLACK YEL YELLOW RESET BRW BROWN RED PINK WHITE FLASH HORN CentriPro Wastewater NOTES PAGE 7 Xylem 1) The tissue in plants that brings water upward from the roots; 2) a leading global water technology company. We’re a global team unified in a common purpose: creating innovative solutions to meet our world’s water needs. Developing new technologies that will improve the way water is used, conserved, and re-used in the future is central to our work. We move, treat, analyze, and return water to the environment, and we help people use water efficiently, in their homes, buildings, factories and farms. In more than 150 countries, we have strong, long-standing relationships with customers who know us for our powerful combination of leading product brands and applications expertise, backed by a legacy of innovation. For more information on how Xylem can help you, go to www.xyleminc.com Xylem Inc. 2881 East Bayard Street Ext., Suite A Seneca Falls, NY 13148 Phone: (866) 325-4210 Fax: (888) 322-5877 www.centripro.com CentriPro is a trademark of Xylem Inc. or one of its subsidiaries. © 2015 Xylem Inc. BCP4 R13 September 2015
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 5.3-c011 66.145661, 2012/02/06-14:56:27 Create Date : 2015:09:10 08:47:29-04:00 Metadata Date : 2015:09:10 08:47:41-04:00 Modify Date : 2015:09:10 08:47:41-04:00 Creator Tool : Adobe InDesign CS6 (Macintosh) Instance ID : uuid:c9e374ad-3855-fb45-8182-110fdb8660a7 Original Document ID : adobe:docid:indd:6116ff89-6a83-11db-bbf7-c0c80c6d23ec Document ID : xmp.id:F77F1174072068118A6DB7D0DB740F2B Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:5CAB0EEC0B2068118083C46F7BEC4583 Derived From Document ID : xmp.did:69662C400B2068118083C46F7BEC4583 Derived From Original Document ID: adobe:docid:indd:6116ff89-6a83-11db-bbf7-c0c80c6d23ec Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CS6 (Macintosh) History Changed : / History When : 2015:09:10 08:47:30-04:00 Format : application/pdf Producer : Adobe PDF Library 10.0.1 Trapped : False Postscript Name : AvenirNextLTPro-Bold, AvenirNextLTPro-Medium, AvenirNextLTPro-Regular Profile Blob : AAADzAAAAALMneSUAAAAAHJzbmYAAAO8KnLz1AAAAA1lbWFuAAAAsAE+NLUAAAAAAoUWAAAAABQCbgASAQEAAAAAAlAABAIBAAAAAAI1AB8DAQAAAAACbgAXBAEAAAAAApsAEAUBAAAAAAJAABQGAQAAAAACqwANCAEAAAAAAfUAIAkBAAAAAAHQABcLAQAAAAAB0AAlDAEAAAAAAaAAMAEDAAEECQGYAAgCAwABBAkBYgA+AwMAAQQJAXgAKAQDAAEECQIVACAFAwABBAkBeAAoBgMAAQQJAlQAGggDAAEECQEiAEAJAwABBAkA2AAuCwMAAQQJANgASgwDAAEECQBoAHQAdABwADoALwAvAHcAdwB3AC4AbABpAG4AbwB0AHkAcABlAC4AYwBvAG0ALwBmAG8AbgB0AGQAZQBzAGkAZwBuAGUAcgBzAEEAZAByAGkAYQBuACAARgByAHUAdABpAGcAZQByACwAIABBAGsAaQByAGEAIABLAG8AYgBhAHkAYQBzAGgAaQAyAC4AMAAwADEAOwBMAEkATgBPADsAQQB2AGUAbgBpAHIATgBlAHgAdABMAFQAUAByAG8ALQBCAG8AbABkAEEAdgBlAG4AaQByAE4AZQB4AHQAIABMAFQAIABQAHIAbwAgAE0AZQBkAGkAdQBtaHR0cDovL3d3dy5saW5vdHlwZS5jb20vZm9udGRlc2lnbmVyc0FkcmlhbiBGcnV0aWdlciwgQWtpcmEgS29iYXlhc2hpAFYAZQByAHMAaQBvAG4AIAAyAC4AMQA7ADIAMAAwADcyLjAwMTtMSU5PO0F2ZW5pck5leHRMVFByby1Cb2xkAEwAaQBuAG8AdAB5AHAAZQAgAEcAbQBiAEhBdmVuaXIgTmV4dCBMVCBQcm8gQm9sZEF2ZW5pck5leHQgTFQgUHJvIEJvbGRWZXJzaW9uIDIuMTsyMDA3TGlub3R5cGUgR21iSGZ5bGcAAAAFAAB+btfvcQsAAAAAIHh0bQAAAAUAAAjMTMFYsQAAAAB4bWZmAAAABQAAAhZqiJUgAAAAACAgbWIAAAAFAAAAAP////8AAAAAdG5mbgAAAAUAAAAA/////wAAAAAgY25lAAAABgAABkREbXJOAAAAAAAA//9uZXJwAAAABQAACGGldiN7AAAAAHlhbGEAAAAFAABbILrHDrMAAAAAbnJlawAAAAUAAAAA/////wAAAABucmtmAAAABQAAHLCDOgAHAAAAAHlhbHcAAAAFAAAACAtTyNoAAAAAIHRtZgAAAANPVFRP, 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, 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 Page Count : 8 Creator : Adobe InDesign CS6 (Macintosh)EXIF Metadata provided by EXIF.tools