542331 1 Goulds Pump And Control Panel Switches
542353 1 Goulds Pump And Control Panel Switches 542353_1_Goulds Pump and Control Panel Switches
542351 1 Goulds Pump And Control Panel Switches 542351_1_Goulds Pump and Control Panel Switches
542354 1 Goulds Pump And Control Panel Switches 542354_1_Goulds Pump and Control Panel Switches
542348 1 Goulds Pump And Control Panel Switches 542348_1_Goulds Pump and Control Panel Switches
542357 1 Goulds Pump And Control Panel Switches 542357_1_Goulds Pump and Control Panel Switches
: Pump 542331 1 Goulds Pump And Control Panel Switches 542331_1_Goulds Pump and Control Panel Switches pdf
Open the PDF directly: View PDF .
Page Count: 8
Download | |
Open PDF In Browser | View PDF |
BCPFS R7 IT T Wastewater CentriPro PUMP / CONTROL PANEL SWITCHES CentriPro ® CentriPro is a brand of ITT Corporation. www.centripro.com Engineered for life CentriPro Pump / Control Panel Switches TERMS TO KNOW Pump Switches are used to directly control the operation of a pump. They are normally wide-angle switches which means they operate over a range of approximately 70º to 90º. Pump switches are available with piggyback plugs and with bare leads. Some can also be used with control panels. Control Switches are designed to only control pumps when used with a control or alarm panel. They cannot handle the high starting amps and running amperage of a pump, only signal or control amperage. NO or Normally Open is a switch with contacts that are open in the hanging position. They are used to pump down or empty a tank. NC or Normally Closed is a switch with contacts that are closed in the hanging position. They are used to pump up or fill a tank. A2T SERIES A2X SERIES SJE Double Float Master Pump Switch MilliAmpMaster™ Mechanical Float Switch Features • Mechanically activated, wide-angle switch designed to control pumps up to 13 FLA, 78 LRA, 120 VAC or 240 VAC. Features • Mechanically activated, snap-action, sealed gold cross-point contacts are designed to activate low current control panels and alarms. ® • This switch consists of two mechanical floats and • Narrow angle Control for Low Voltage AC a splice tube. The splice tube contains a holding relay which eliminates pump chatter in turbulent conditions. or DC applications. • Operate with differential of 45º above or • Includes standard mounting clamps and boxed below horizontal. packaging. • Electrical Load – low current • Cable attached to float housing: flexible non-arcing applications • 125 VAC – Max. Load .1 amps (Min. Load .16 milliamps) • 30 VDC – Max. Load .1 amps (Min. Load .16 milliamps) • 5 VDC - Minimum Load 1 milliamp 16 gauge, 2 conductor (UL, CSA) SJOW, water-resistant (CPE). • Cable above splice: flexible 14 gauge, 3 conductor (UL, CSA) SJTW, water-resistant, thermoplastic. • UL Listed for use in non-potable water and sewage. • Floats: 2.74" diameter x • CSA Certified 4.83" long (7.0 x 12.3 cm) high impact, corrosion resistant, PP housing for use in sewage and non-potable water up to 140º F (60º C). • Mounting clamp for attaching to discharge pipe is standard. • Not sensitive to rotation. • Not sensitive to rotation or turbulence. • Maximum submergence or water depth, 30' (9 meters), 13 psi. • Pumping range: 10" to 56". • Flexible 18 gauge, 2 conductor SJOW water resistant cable. • Available for pump up or pump down ap- • Impact and corrosion resistant, polypropylene float housing for • For confined applications requiring an ac- • Use with Intrinsically Safe Barriers (as used with explosion- plications. use in sewage and water up to 140 º F. curate pumping range. proof pumps), PLC’s, solar applications and other low current control panel or alarm applications. • UL Recognized for use in non-potable water and sewage. • CSA Certified. • See chart for data and order numbers. • Cable lengths of 10', 20' and 30'. ® • Standard order numbers are for Normally Open (NO) switches. ® • Normally Closed (NC) or Pump Down switches are available as a special order by adding a ”U” suffix. See Nomenclature on last page. • Float comes with blue cap for easy identification. 2 CentriPro Pump / Control Panel Switches A2D SERIES A2HT SERIES SJE PumpMaster® Pump Switch High Temperature Float Switch Features • Mechanically activated, heavy duty contacts, wide angle operation. Features • Temperature Rating: 221º F (105º C) • Wide Angle Switch: contacts open @ 45º below horizontal and • Passed NSF standard 61 protocol by an ap- close at 45º above horizontal proved Water Quality Association laboratory. • Float Material: PC/ABS (Polycarbonate ABS) •Controls pumps up to 1/2 HP at 120 VAC • Cord Material: Teflon coating and 1 HP at 230 VAC. • Non-corrosive PVC housing for use in • Ratings: 13 Maximum Amps, ½ HP, 115/230 V • Not sensitive to rotation or turbulence. • Nomenclature: see last page • Pumping range: 7" to 36". • Available lengths: 20', 30' and 50' * liquids up to 140º F (60º C). • Float Dimensions: 4.63" Long x 2.63" Diameter • 16 AWG, SJOW cord is available ® * No other lengths available in this Series. with or without piggyback plug. ® • Available as pump up, pump down and SPDT models, see Nomenclature Chart. A2KM23WP3 Conery Mechanical Float Pack of 3 • For potable water, water or sewage applications. Features • Pack of three floats • Narrow angle control for panel hookup • 15' cord - Type SJOOW 16/2 have leads • Float material: ABS material • 5º contact closes • Pump down operation • UL Recognized for use in water and sewage. • CSA Certified. ® • See chart for amperage range and other data. ® A2E SERIES SJE PumpMaster Plus® Pump Switch Ratings • 10 Amp rating • Mechanically activated • Temperature Rating: Maximum temperature 190º F (88º C) Features • Controls pumps up to 3⁄4 HP at 120 VAC and 2 HP at 230 VAC. • 14 AWG, SJOW cord is available with or without piggyback plug. • All other features are the same as A2D PumpMaster Series above. 3 CentriPro Pump / Control Panel Switches A2G SERIES A2H SERIES SJE AmpMaster Pump Switch SJE VerticalMaster Pump Switch Features • Mechanically activated, heavy duty contacts, wide angle operation. Features • Mechanically activated vertical operation. • Controls pumps up to 11⁄2 HP at 115 VAC • Controls pumps up to 1⁄2 HP at • Non-corrosive PVC housing for use in • Non-corrosive PVC housing for use • Maximum pump running current of • Overall Dimensions: 12" High, • Not sensitive to rotation or turbulence. • Not sensitive to rotation. • Pumping range: 9" to 24". • Pumping range: .75" to 6.5". • 12 AWG, SJOW cord is available • 16 AWG, SJOW cord is available • Available for pump down • Available for pump down • UL Recognized for use in non- • For confined applications requiring • CSA Certified. • Stainless steel mounting bracket and hose clamp. ® ® and 3 HP at 250 VAC. 120 VAC and 1 HP at 230 VAC. liquids up to 140º F (60º C). in liquids up to 140º F (60º C). 20 amps. 5" Deep, 3" Wide. only with bare leads. with or without piggyback plug. applications only. applications only. potable water and sewage. an accurate pumping range. • See chart for amperage range and other data. • UL Recognized for use in non-potable water and sewage. ® ® • CSA Certified. ® • See chart for amperage range and other data. ® A2P SERIES SJE MicroMaster Plus ® A2J SERIES Features • Mechanically activated, snap action contacts, wide angle. SJE VerticalMaster II Pump Switch ® Features • Mechanically activated vertical operation. • Pump down operation (optional pump up available) • UL Recognized for use in non-potable water and sewage. • Maximum running 10 amps. • CSA Certified. • Non-corrosive PVC housing for use in liquids up to • See chart for amperage range and other data. 140º F (60º C). • Controls pump up to 1 HP at 115 VAC and 1.5 HP at 230 VAC • Overall Dimensions: 12" High, 5" Deep, 3" Wide. • 16 AWG, SJOW cord • Not sensitive to rotation. • Pumping range: 8" to 36" • Pumping range: .75" to 6.5" (pump down only) • 18 AWG, SJOW cord • For confined applications requiring an accurate pumping range. • Stainless steel mounting bracket and hose clamp. • UL Recognized for use in non-potable water and sewage. • CSA Certified. • See chart for amperage range and other data. 4 CentriPro Pump / Control Panel Switches A2N SERIES A2S SERIES SJE SignalMaster Control Switch CentriPro Diaphragm Pump or Control Switch Features • Mechanically activated, narrow angle, designed to activate pump control panels or alarms. Features • Mechanical contacts. ® ® • Cast iron housing and BUNA-N diaphragm. • For use in liquids up to 104º F (40º C). • Not designed for direct connection to pump. • Control differential: pump turns on at 18" and off at 12" • Passed NSF standard 61 protocol by an submergence. approved Water Quality Association laboratory. • 18/3 AWG, SJTW cord w/breather tube is available with or without piggyback plug. • Non-corrosive PVC housing for use in • Available only as NO for pump down operation. liquids up to 140º F (60º C). • Not sensitive to rotation. • For wastewater or sewage applications. • Control differential: 1.5" above or • Supplied with a mounting bracket for mounting to pump. below horizontal. • See chart for amperage range and other data. • Available as NO (pump down), NC (pump up) or SPDT model, see Nomenclature page. • For potable water, water or sewage applications. • Supplied with a pipe clamp for mounting to pipe. • UL Listed for use in water and sewage. • CSA Certified. • See chart for amperage range and other data. ® UL ® • Normally open - comes with yellow cap for easy identification. • Normally closed - comes with white cap for easy identification. • Single pole double throw - comes with green cap for easy identification. A2WT SJ ELECTRO WEIGHT A2WTC CONERY WEIGHT • Adjustable snap in design. • Works with all float switches shown. • PVC • Zinc plated cord weight • Works with all float switches 5 CentriPro Pump / Control Panel Switches PUMP SWITCHES (WIDE ANGLE) can be connected directly to a pump. CONTROL SWITCHES (NARROW ANGLE) can only be used with control panels or alarm panels. ORDER NUMBER MOUNTING BARE PUMP CONTROL (1) (2) LEADS SWITCH SWITCH N.0. N.C. STRAP WEIGHT MAXIMUM RUNNING AMPS MAXIMUM STARTING AMPS CORD LENGTH (FEET) A2D13 13 85 10 X X — A2D23U 13 85 15 X X — A2D23W 13 85 15 X X — X A2D33 13 85 20 X X — X A2D33U 13 85 20 X X — A2D33W 13 85 20 X X — X X A2D53W 13 85 30 X X — X X A2D63W 13 85 50 X X — X X A2D83W 13 85 100 X X — X X A2E23 15 85 15 X X — X A2E23U 15 85 15 X X — A2E33 15 85 20 X X A2E53 15 85 30 X X A2E53U 15 85 30 X X — A2E63 15 85 50 X X — A2E63U 15 85 50 X X — X X A2E73 15 85 75 X X — X X A2E83 15 85 100 X X — X X A2G33 20 120 20 X X — X X A2G43 20 120 25 X X — X X A2G53 20 120 30 X X — X X A2G63 20 120 50 X X — X X A2HT33 13 58 20 X X X X X A2HT53 13 58 30 X X X X X A2HT63 13 58 50 X X X X X A2N13 5 N/A 10 X — X X X A2N33 5 N/A 20 X — X X X A2N33U 5 N/A 20 X — X A2N93 5 N/A 125 X — X X X A2S23① 10 N/A 15 X — X X X A2S53① 10 N/A 30 X — X X X A2S63① 10 N/A 50 X — X X X A2X13 See description N/A 10 X — X X X A2X33 See description N/A 20 X — X X X A2X53 See description N/A 30 X — X X X N.O. (1) = PUMP DOWN N.C. (2) = PUMP UP ① Diaphragm switch with 6" differential. 6 X X X X X X X X X — X X — X X X X X X X X X X CentriPro Pump / Control Panel Switches WIDE ANGLE 115 VOLT PIGGYBACK FLOAT SWITCHES TO DIRECTLY CONTROL PUMPS ORDER NUMBER MAXIMUM AMPS START AMPS 115 V PLUG CORD LENGTH FEET (1) N.0. (2) N.C. A2D11 13 85 X 10 X X A2D31 13 85 X 20 X X A2D51 13 85 X 30 X X A2D61 13 85 X 50 X X A2E21 15 85 X 15 X X A2E31 15 85 X 20 X X A2E31U 15 85 X 20 X X A2E51 15 85 X 30 X X A2E61 15 85 X 50 X X A2H11 13 60 X 10 X X A2H31 13 60 X 20 X X A2J11 15 85 X 10 X X A2J21 15 85 X 15 X X A2J31 15 85 X 20 X X A2P01 13 78 X 10 X X A2P21 13 78 X 15 X X A2P31 13 78 X 20 X X A2P51 13 78 X 30 X X A2S21 13 60 X 15 X X A2T31 13 78 X 20 X X A2T51 13 78 X 30 X X MOUNTING STRAP WIDE ANGLE 230 VOLT PIGGYBACK FLOAT SWITCHES TO DIRECTLY CONTROL PUMPS ORDER NUMBER MAXIMUM AMPS START AMPS 230 V PLUG CORD LENGTH FEET (1) N.0. (2) N.C. A2D12 13 85 X 10 X X A2D32 13 85 X 20 X X A2E22 15 85 X 15 X X A2E32 15 85 X 20 X X A2E32U 15 85 X 20 A2E52 15 85 X A2E62 15 85 A2H12 12 A2H32 12 A2J12 MOUNTING STRAP X X 30 X X X 50 X X 60 X 10 X X 60 X 20 X X 10 60 X 10 X X A2J22 10 60 X 15 X X A2S22 13 60 X 15 X X A2T32 13 78 X 20 X X A2T52 13 78 X 30 X X N.O. (1) = PUMP DOWN N.C. (2) = PUMP UP 7 NOMENCLATURE 1st and 2nd Characters A2 = Float Switch 3rd Character D = PumpMaster® – SJE E = PumpMaster Plus® – SJE G = AmpMaster® – SJE H = VerticalMaster® – SJE J = VerticalMaster® II – SJE ➁ N = SignalMaster™ – SJE P = MicroMaster® Plus – SJE ➁ R = MicroMaster® – SJE ➁ S = C I Diaphragm Level Switch – MP T = Double Float® Master – SJE X = MilliAmpMaster™ 4th Character 1 = 10' 2 = 15' ➀ 3 = 20' 4 = 25' ➀ 5 = 30' 6 = 50' 7 = 75' Only available on select 8 = 100' control switches. 9 = 125' 5th Character 1 = 115 V piggyback 2 = 230 V piggyback 3 = Bare lead 4 = Single pole double throw (SPDT) 6th Character (optional) U = Pump Up or Normally Closed (NC) W = A2WT Cable Weight B = Bulk Packed (internal only) Characters 1-4 A2HT = High Temperature Float Switch A2KM = Conery 3 pack Character 5 * Length (ft) 2 = 15' (Conery only) 3 = 20' 5 = 30' 6 = 50' Character 6 1 = 115V Piggyback Plug 2 = 230V Piggyback Plug 3 = Bare Leads 4 = Single Pole Double Throw (SPDT) Characters 7, 8, 9 PK3 = Pack of three * No other lengths available in this Series. ➀ Only available on existing models. ➁ Discontinued models – contained mercury. CentriPro ® ITT 2881 East Bayard Street, Seneca Falls, NY 13148 Phone: (315) 568-7123 • Fax: (315) 568-7973 www.centripro.com Junior Super Single®, Super Single®, PumpMaster®, PumpMaster Plus®, AmpMaster®, MilliAmpMaster™, VerticalMaster®, VerticalMaster® II, Sensor Float®, Sensor Float® Mini, SignalMaster®, MicroMaster®, and MicroMaster® Plus are registered trademarks and tradenames of SJ Electro Systems, Inc. Double Float® Master is a registered trademark of SJE-Rhombus® Controls. CentriPro is a registered trademark of ITT Corporation. ITT, the Engineered Blocks Symbol and Engineered for Life are registered trademarks of ITT Manufacturing Enterprises, Inc. Copyright © 2010 ITT Corporation BCPFS R7 April, 2010 SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE. Printed in U.S.A. IT T Engineered for life
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.4 Linearized : Yes Tagged PDF : Yes XMP Toolkit : Adobe XMP Core 4.2.2-c063 53.352624, 2008/07/30-18:05:41 Create Date : 2010:04:14 13:40:11-04:00 Metadata Date : 2010:04:14 13:40:22-04:00 Modify Date : 2010:04:14 13:40:22-04:00 Creator Tool : Adobe InDesign CS4 (6.0.4) Thumbnail Format : JPEG Thumbnail Width : 256 Thumbnail Height : 256 Thumbnail Image : (Binary data 8505 bytes, use -b option to extract) Instance ID : uuid:fbe67b99-6964-7940-941e-7ef9385da05b Document ID : adobe:docid:indd:fe39093b-2f69-11db-b15f-8c318022320c Original Document ID : adobe:docid:indd:fe39093b-2f69-11db-b15f-8c318022320c Rendition Class : proof:pdf Derived From Instance ID : fe39093a-2f69-11db-b15f-8c318022320c Derived From Document ID : adobe:docid:indd:4bf24922-2f63-11db-b15f-8c318022320c History Action : saved, saved, saved, saved, saved, saved, saved, saved, saved History Instance ID : xmp.iid:63B4D79D1E20681195FEF5424F377D72, xmp.iid:64B4D79D1E20681195FEF5424F377D72, xmp.iid:01801174072068119109B095D39BCE49, xmp.iid:0580117407206811ACAF97F8D0B8F8D6, xmp.iid:0680117407206811ACAF97F8D0B8F8D6, xmp.iid:0880117407206811ACAF97F8D0B8F8D6, xmp.iid:F77F117407206811994CF26C8A1C1D40, xmp.iid:F77F117407206811AFFD82504392B472, xmp.iid:018011740720681195FEBC8ABA49C636 History When : 2009:06:03 11:33:44-04:00, 2009:06:03 11:33:45-04:00, 2010:02:04 11:08:34-05:00, 2010:02:05 11:57:56-05:00, 2010:02:05 13:53:31-05:00, 2010:02:05 14:20:19-05:00, 2010:03:01 08:30:49-05:00, 2010:03:01 10:26:20-05:00, 2010:04:14 12:33:28-04:00 History Software Agent : Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0, Adobe InDesign 6.0 History Changed : /, /metadata, /, /, /, /, /, /, / Manifest Link Form : ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream, ReferenceStream Manifest Placed X Resolution : 72.00, 300.00, 300.00, 300.00, 300.00, 120.00, 72.00 Manifest Placed Y Resolution : 72.00, 300.00, 300.00, 300.00, 300.00, 120.00, 72.00 Manifest Placed Resolution Unit : Inches, Inches, Inches, Inches, Inches, Inches, Inches Manifest Reference Instance ID : uuid:6EF441E862A211DC94EC8D62B1C78F43, uuid:67FFAC4001EF11DBA7AD9FDCC5EF833F, uuid:67FFAC4001EF11DBA7AD9FDCC5EF833F, uuid:67FFAC4301EF11DBA7AD9FDCC5EF833F, uuid:67FFAC4301EF11DBA7AD9FDCC5EF833F, uuid:FC8745E4CA4311DBBB48BEB44BC5C7F3, uuid:6EF441E862A211DC94EC8D62B1C78F43 Manifest Reference Document ID : uuid:6EF441E762A211DC94EC8D62B1C78F43, adobe:docid:photoshop:37dc7968-007c-11db-bca8-e95a9e1ef6ca, adobe:docid:photoshop:37dc7968-007c-11db-bca8-e95a9e1ef6ca, adobe:docid:photoshop:948e9361-007c-11db-bca8-e95a9e1ef6ca, adobe:docid:photoshop:948e9361-007c-11db-bca8-e95a9e1ef6ca, uuid:FC8745E3CA4311DBBB48BEB44BC5C7F3, uuid:6EF441E762A211DC94EC8D62B1C78F43 Doc Change Count : 437 Format : application/pdf Producer : Adobe PDF Library 9.0 Trapped : False Page Count : 8 Creator : Adobe InDesign CS4 (6.0.4)EXIF Metadata provided by EXIF.tools