AQUAVAR®
Intelligent Pump Controller
TECHNICAL BROCHURE
BCPAQIPC R3
PAGE 2
Residential Water Systems
CentriPro
INTRODUCTION
The Aquavar® Intelligent Pump Controller from CentriPro utilizes an all new Aquavar platform, and combines
it with over 20 years of variable speed pumping experience. The Aquavar is designed to provide variable
frequency pumping control of speed, pressure, ow and level over a wide range of submersible and above
ground applications. Here are just a few of the features and benets of this versatile product:
Application specic “Start-Up Genie” guides you through quick and easy commissioning
Removable, graphical control panel with display
Fully backlit display with large text makes the control pad easy to read
Info key activates on board parameter and fault descriptions
My Personal Menu allows user to focus on specic user selected and saved parameters
Alarm Log key for quick access to alarms and maintenance events
Alarm Log records the last 5 alarms
Hand on, Auto on, and Off buttons for easy pump operation at the keypad – No toggling between local and
remote operation!
Modbus® RTU included in standard drive – Other communications available with option cards
Capable of controlling up to 2 xed speed pumps, with one standard drive
Duplex variable speed pumping control with auto lead/lag and alternate
USB Connectivity – Commission and monitor through PC software
Transducer assembly (0-300 psi) and 16’ foot shielded cable
Standard dual DC-link reactors – Reduces the level of harmonics similar to a 5% AC line reactor without the
voltage drop across the full load range!
EMC/RFI lters designed to reduce drive noise emissions and interference to strict standards.
•AutomaticMotorAdaption–Foroptimizedperformanceandefciency
•AutomizedEnergyOptimization–Regulatesoutputvoltagetoimprovesystemefciencyasloadschange
Protects the pump from damage due to cavitation, dead head and blocked suction.
Helps protect the motor from short circuit, phase loss, overload, undervoltage, overvoltage
Large connection area allows more space for incoming power and motor wiring
TRANSDUCER
Includes: 4-20mA, 300psi transducer and 16’ cable
Used for: Pressure transducer for constant pressure applications.
Transducer will be delivered with your drive when you
use the “1” Transducer character.
NOTE: 9K515 – Repair part number for the transducer
9K391 – Repair part number for the transducer and 16' cable
PAGE 3
Residential Water Systems
CentriPro
Real Time
Drive Status
Actual System
Pressure and
Setpoint Pressure
Display
Info button provides
on-board descriptions
of parameters
Alarm Reset
Quick access
to Start-Up
Genie, Personal
Menu and drive
parameters
4-way
directional
buttons for
scrolling
parameters
LEDs for
On, Warning
and Alarm
Easily accessible
Hand/Off/Auto
Buttons
KEYPAD LAYOUT
PAGE 4
Residential Water Systems
CentriPro
NOMENCLATURE
AV B 2 0015 D 0 X 0 D 0 X 1
Coating / EMC Filter Options**
0 = Standard Protection w/ H2 EMC Filter
(Standard EMC Filter)
1 = Standard Protection w/ H3 EMC Filter
2 = Standard Protection w/ H1 EMC Filter
3 = 3C3 Board Coating w/ H2 EMC Filter
(Standard EMC Filter)
4 = 3C3 Board Coating w/ H3 EMC Filter
5 = 3C3 Board Coating w/ H1 EMC Filter
Disconnect Options
X = No Accessories
S = Standard Disconnect (Single Phase Only)
D = Fused Disconnect
Backup Options
0 = No Backup 4 = 24VDC Backup
(Requires External Power)
Type – B=Basic Drive
* Motor mounted units are not available in the initial launch. Product news will be issued when this conguration is available.
** 575V and single phase 10, 20, and 30HP are not avaialble with EMC lter. These are sold without lter as standard.
*** Single phase 460V are not available with the initial Launch. Product news will be issued when this voltage is available.
Model – AV
Transducer
1=Transducer 2=No Transducer
Motor Mounting Options*
X = No Accessories M = Motor Mount Hardware
Example Product Code
Input/Output Options
X = No Additional I/O
A = Analog I/O and
Real-time Clock
B = General Purpose I/O
C = PTC Thermistor Card
D = PT100 Sensor Input
E = Relay Card
Enclosure
A = TYPE 1 (IP21)
B = TYPE 12 (IP55)
C = TYPE 3R
D = TYPE 4X (IP66)
E = IP20 (Chassis)
Communications Options
0 = Standard Communication
1 = Modbus TCP
2 = Probus
3 = DeviceNet
4 = LonWorks
5 = Pronet
6 = Ethernet IP
Nominal HP
0015
0020
0030
0050
0075
0100
0150
0200
0250
0300
0400
0500
0600
0750
1000
1250
Phase/Voltage
1 = 1/230
2 = 3/230
3 = 1/460***
4 = 3/380-460
5 = 3/575
PAGE 5
Residential Water Systems
CentriPro
PRODUCT CHART – IP20 CHASSIS
Input
Voltage
Input
Phase
IP20 Chassis
Base Model
Continuous
Output Amps @
45°C Ambient
Continuous
Output Amps @
50°C Ambient
Nominal
Surface
Motor HP*
Nominal Sub.
Motor HP*
4" / 6" & Up
Frame
Size
208-230 3
AVB20015E0X0X0X2 6.6 5.9 1.5 1.5
A2AVB20020E0X0X0X2 7.5 6.8 2 2
AVB20030E0X0X0X2 10.6 9.5 3 3
AVB20050E0X0X0X2 16.7 15.0 5 A3
AVB20075E0X0X0X2 24.2 21.8 7.5 5
B3AVB20100E0X0X0X2 30.8 27.7 10 7.5
AVB20150E0X0X0X2 46.2 41.6 15 10 / 15
AVB20200E0X0X0X2 59.4 53.5 20 15 B4
AVB20250E0X0X0X2 74.8 67.3 25 20
AVB20300E0X0X0X2 88 79.2 30 25 C3
AVB20400E0X0X0X2 115 103.5 40 30
AVB20500E0X0X0X2 143 128.7 50 C4
AVB20600E0X0X0X2 170 153.0 60
380-460 3
AVB40015E0X0X0X2 2.7 2.4 1.5 1
A2
AVB40020E0X0X0X2 3.4 3.1 2 1.5
AVB40030E0X0X0X2 4.8 4.3 3 2
AVB40050E0X0X0X2 8.2 7.4 5 3
AVB40075E0X0X0X2 11 9.9 7.5 5 A3
AVB40100E0X0X0X2 14.5 13.1 10 7.5
AVB40150E0X0X0X2 21 18.9 15 10
B3AVB40200E0X0X0X2 27 24.3 20 15
AVB40250E0X0X0X2 34 30.6 25 20
AVB40300E0X0X0X2 40 36.0 30 25
B4AVB40400E0X0X0X2 52 46.8 40 30
AVB40500E0X0X0X2 65 58.5 50 40
AVB40600E0X0X0X2 80 72.0 60 50 C3
AVB40750E0X0X0X2 105 94.5 75 60
AVB41000E0X0X0X2 130 117.0 100 75 C4
AVB41250E0X0X0X2 160 144.0 125 100
575 3
AVB50015E0X0X0X2 2.4 2.2 1.5 1.5
A3
AVB50020E0X0X0X2 2.7 2.4 2
AVB50030E0X0X0X2 3.9 3.5 3 2
AVB50050E0X0X0X2 6.1 5.5 5 3
AVB50075E0X0X0X2 9 8.1 7.5 5
AVB50100E0X0X0X2 11 9.9 10 7.5
AVB50150E0X0X0X2 18 16.2 15
B3AVB50200E0X0X0X2 22 19.8 20
AVB50250E0X0X0X2 27 24.3 25
AVB50300E0X0X0X2 34 30.6 30
B4AVB50400E0X0X0X2 41 36.9 40
AVB50500E0X0X0X2 52 46.8 50
AVB50600E0X0X0X2 62 55.8 60 C3
AVB50750E0X0X0X2 83 74.7 75
AVB51000E0X0X0X2 100 90.0 100 C4
AVB51250E0X0X0X2 131 117.9 125
* Nominal HP values are for reference only. Size Aquavar by maximum output amps of the motor.
PAGE 6
Residential Water Systems
CentriPro
PRODUCT CHART – TYPE 1
Input
Voltage
Input
Phase
TYPE
1
Base Model
Continuous
Output Amps @
45°C Ambient
Continuous
Output Amps @
50°C Ambient
Nominal
Surface
Motor Hp*
Nominal Sub.
Motor HP*
4" / 6" & Up
Frame
Size
208-230 1
AVB10020A0X0X0X1 7.5 6.8 2 2
B1
AVB10030A0X0X0X1 10.6 9.5 3 3
AVB10050A0X0X0X1 16.7 15.0 5
AVB10075A0X0X0X1 24.2 21.8 7.5 5
AVB10100A0X0X0X1 30.8 27.7 10 7.5 / 5 B2
AVB10200A0X0X0X1 59.4 53.5 20 10 C1
AVB10300A0X0X0X1 88 79.2 30 15 & 20 C2
208-230 3
AVB20015A0X0X0X1 6.6 5.9 1.5 1.5
A2AVB20020A0X0X0X1 7.5 6.8 2 2
AVB20030A0X0X0X1 10.6 9.5 3 3
AVB20050A0X0X0X1 16.7 15.0 5 A3
AVB20075A0X0X0X1 24.2 21.8 7.5 5
B1
AVB20100A0X0X0X1 30.8 27.7 10 7.5
AVB20150A0X0X0X1 46.2 41.6 15 10 / 15
AVB20200A0X0X0X1 59.4 53.5 20 15 B2
AVB20250A0X0X0X1 74.8 67.3 25 20
C1AVB20300A0X0X0X1 88 79.2 30 25
AVB20400A0X0X0X1 115 103.5 40 30
AVB20500A0X0X0X1 143 128.7 50 C2
AVB20600A0X0X0X1 170 153.0 60
380-460 3
AVB40015A0X0X0X1 2.7 2.4 1.5 1
A2
AVB40020A0X0X0X1 3.4 3.1 2 1.5
AVB40030A0X0X0X1 4.8 4.3 3 2
AVB40050A0X0X0X1 8.2 7.4 5 3
AVB40075A0X0X0X1 11 9.9 7.5 5 A3
AVB40100A0X0X0X1 14.5 13.1 10 7.5
AVB40150A0X0X0X1 21 18.9 15 10
B1AVB40200A0X0X0X1 27 24.3 20 15
AVB40250A0X0X0X1 34 30.6 25 20
AVB40300A0X0X0X1 40 36.0 30 25 B2
AVB40400A0X0X0X1 52 46.8 40 30
AVB40500A0X0X0X1 65 58.5 50 40
C1AVB40600A0X0X0X1 80 72.0 60 50
AVB40750A0X0X0X1 105 94.5 75 60
AVB41000A0X0X0X1 130 117.0 100 75 C2
AVB41250A0X0X0X1 160 144.0 125 100
575 3
AVB50015A0X0X0X1 2.4 2.2 1.5 1.5
A3
AVB50020A0X0X0X1 2.7 2.4 2
AVB50030A0X0X0X1 3.9 3.5 3 2
AVB50050A0X0X0X1 6.1 5.5 5 3
AVB50075A0X0X0X1 9 8.1 7.5 5
AVB50100A0X0X0X1 11 9.9 10 7.5
AVB50150A0X0X0X1 18 16.2 15
B1AVB50200A0X0X0X1 22 19.8 20
AVB50250A0X0X0X1 27 24.3 25
AVB50300A0X0X0X1 34 30.6 30
B2AVB50400A0X0X0X1 41 36.9 40
AVB50500A0X0X0X1 52 46.8 50
AVB50600A0X0X0X1 62 55.8 60 C1
AVB50750A0X0X0X1 83 74.7 75
AVB51000A0X0X0X1 100 90.0 100 C2
AVB51250A0X0X0X1 131 117.9 125
* Nominal HP values are for reference only. Size Aquavar by maximum output amps of the motor.
PAGE 7
Residential Water Systems
CentriPro
Input
Voltage
Input
Phase
TYPE 12
Base Model
TYPE 3R
Base Model
Cont. Output
Amps @ 45°C
Ambient
Cont. Output
Amps @ 50°C
Ambient
Nominal
Surface
Motor HP*
Nominal Sub.
Motor HP*
4" / 6" & Up
Frame
Size
DV / DT
Load Filter
NEMA 3R**
208-
230
1
AVB10015B0X0X0X1 AVB10015C0X0X0X1
6.6 5.9 1.5 1.5 A5
V1K8A03
AVB10020B0X0X0X1 AVB10020C0X0X0X1
7.5 6.8 2 2
B1
V1K8A03
AVB10030B0X0X0X1 AVB10030C0X0X0X1
10.6 9.5 3 3
V1K12A03
AVB10050B0X0X0X1 AVB10050C0X0X0X1
16.7 15.0 5
V1K18A03
AVB10075B0X0X0X1 AVB10075C0X0X0X1
24.2 21.8 7.5 5
V1K25A03
AVB10100B0X0X0X1 AVB10100C0X0X0X1
30.8 27.7 10 7.5 / 5 B2
V1K35A03
AVB10200B0X0X0X1 AVB10200C0X0X0X1
59.4 53.5 20 10 C1
V1K80A03
AVB10300B0X0X0X1 AVB10300C0X0X0X1
88 79.2 30 20 / 15 C2
V1K110A03
3
AVB20015B0X0X0X1 AVB20015C0X0X0X1
6.6 5.9 1.5 1.5
A5
V1K8A03
AVB20020B0X0X0X1 AVB20020C0X0X0X1
7.5 6.8 2 2
V1K8A03
AVB20030B0X0X0X1 AVB20030C0X0X0X1
10.6 9.5 3 3
V1K12A03
AVB20050B0X0X0X1 AVB20050C0X0X0X1
16.7 15.0 5
V1K18A03
AVB20075B0X0X0X1 AVB20075C0X0X0X1
24.2 21.8 7.5 5
B1
V1K25A03
AVB20100B0X0X0X1 AVB20100C0X0X0X1
30.8 27.7 10 7.5
V1K35A03
AVB20150B0X0X0X1 AVB20150C0X0X0X1
46.2 41.6 15 10 / 15
V1K55A03
AVB20200B0X0X0X1 AVB20200C0X0X0X1
59.4 53.5 20 15 B2
V1K80A03
AVB20250B0X0X0X1 AVB20250C0X0X0X1
74.8 67.3 25 20
C1
V1K80A03
AVB20300B0X0X0X1 AVB20300C0X0X0X1
88 79.2 30 25
V1K110A03
AVB20400B0X0X0X1 AVB20400C0X0X0X1
115 103.5 40 30
V1K130A03
AVB20500B0X0X0X1 AVB20500C0X0X0X1
143 128.7 50 C2
V1K160A03
AVB20600B0X0X0X1 AVB20600C0X0X0X1
170 153.0 60
V1K200A03
380-
460 3
AVB40015B0X0X0X1 AVB40015C0X0X0X1
2.7 2.4 1.5 1
A5
V1K8A03
AVB40020B0X0X0X1 AVB40020C0X0X0X1
3.4 3.1 2 1.5
V1K8A03
AVB40030B0X0X0X1 AVB40030C0X0X0X1
4.8 4.3 3 2
V1K8A03
AVB40050B0X0X0X1 AVB40050C0X0X0X1
8.2 7.4 5 3
V1K12A03
AVB40075B0X0X0X1 AVB40075C0X0X0X1
11 9.9 7.5 5
V1K12A03
AVB40100B0X0X0X1 AVB40100C0X0X0X1
14.5 13.1 10 7.5
V1K18A03
AVB40150B0X0X0X1 AVB40150C0X0X0X1
21 18.9 15 10
B1
V1K25A03
AVB40200B0X0X0X1 AVB40200C0X0X0X1
27 24.3 20 15
V1K35A03
AVB40250B0X0X0X1 AVB40250C0X0X0X1
34 30.6 25 20
V1K35A03
AVB40300B0X0X0X1 AVB40300C0X0X0X1
40 36.0 30 25 B2
V1K55A03
AVB40400B0X0X0X1 AVB40400C0X0X0X1
52 46.8 40 30
V1K55A03
AVB40500B0X0X0X1 AVB40500C0X0X0X1
65 58.5 50 40
C1
V1K80A03
AVB40600B0X0X0X1 AVB40600C0X0X0X1
80 72.0 60 50
V1K80A03
AVB40750B0X0X0X1 AVB40750C0X0X0X1
105 94.5 75 60
V1K110A03
AVB41000B0X0X0X1 AVB41000C0X0X0X1
130 117.0 100 75 C2
V1K130A03
AVB41250B0X0X0X1 AVB41250C0X0X0X1
160 144.0 125 100
V1K160A03
575 3
AVB50015B0X0X0X1 AVB50015C0X0X0X1
2.4 2.2 1.5 1.5
A5
V1K8A03
AVB50020B0X0X0X1 AVB50020C0X0X0X1
2.7 2.4 2
V1K8A03
AVB50030B0X0X0X1 AVB50030C0X0X0X1
3.9 3.5 3 2
V1K8A03
AVB50050B0X0X0X1 AVB50050C0X0X0X1
6.1 5.5 5 3
V1K8A03
AVB50075B0X0X0X1 AVB50075C0X0X0X1
9 8.1 7.5 5
V1K12A03
AVB50100B0X0X0X1 AVB50100C0X0X0X1
11 9.9 10 7.5
V1K12A03
AVB50150B0X0X0X1 AVB50150C0X0X0X1
18 16.2 15
B1
V1K18A03
AVB50200B0X0X0X1 AVB50200C0X0X0X1
22 19.8 20
V1K25A03
AVB50250B0X0X0X1 AVB50250C0X0X0X1
27 24.3 25
V1K35A03
AVB50300B0X0X0X1 AVB50300C0X0X0X1
34 30.6 30
B2
V1K35A03
AVB50400B0X0X0X1 AVB50400C0X0X0X1
41 36.9 40
V1K55A03
AVB50500B0X0X0X1 AVB50500C0X0X0X1
52 46.8 50
V1K55A03
AVB50600B0X0X0X1 AVB50600C0X0X0X1
62 55.8 60 C1
V1K80A03
AVB50750B0X0X0X1 AVB50750C0X0X0X1
83 74.7 75
V1K110A03
AVB51000B0X0X0X1 AVB51000C0X0X0X1
100 90.0 100 C2
V1K110A03
AVB51250B0X0X0X1 AVB51250C0X0X0X1
131 117.9 125
V1K160A03
* Nominal HP values are for reference only. Size Aquavar by maximum output amps of the motor.
** dv/dt lter recommended for applications with motor leads longer than 50'. It is recommended to use the dv/dt lter
with all submersible applications. dv/dt lter is supplied with all Aquavar ordered with Accessories code "F".
PRODUCT CHART – TYPE 12 & TYPE 3R
PAGE 8
Residential Water Systems
CentriPro
PRODUCT CHART – TYPE 4X
Input
Voltage
Input
Phase
TYPE
4X
Base Model
Continuous
Output
Amps @ 45°C
Ambient
Continuous
Output
Amps @ 50°C
Ambient
Nominal
Surface
Motor HP*
Nominal
Submersible
Motor HP*
4" / 6" & Up
Frame
Size
DV / DT
Load Filter
NEMA 3R**
208-230 1
AVB10015D0X0X0X1 6.6 5.9 1.5 1.5 A5 V1K8A03
AVB10020D0X0X0X1 7.5 6.8 2 2
B1
AVB10030D0X0X0X1 10.6 9.5 3 3 V1K12A03
AVB10050D0X0X0X1 16.7 15.0 5 V1K18A03
AVB10075D0X0X0X1 24.2 21.8 7.5 5 V1K25A03
AVB10100D0X0X0X1 30.8 27.7 10 7.5 / 5 B2 V1K35A03
AVB10200D0X0X0X1 59.4 53.5 20 10 C3 V1K80A03
AVB10300D0X0X0X1 88 79.2 30 15 & 20 C4 V1K110A03
208-230 3
AVB20015D0X0X0X1 6.6 5.9 1.5 1.5
A5
V1K8A03
AVB20020D0X0X0X1 7.5 6.8 2 2
AVB20030D0X0X0X1 10.6 9.5 3 3 V1K12A03
AVB20050D0X0X0X1 16.7 15.0 5 V1K18A03
AVB20075D0X0X0X1 24.2 21.8 7.5 5
B1
V1K25A03
AVB20100D0X0X0X1 30.8 27.7 10 7.5 V1K35A03
AVB20150D0X0X0X1 46.2 41.6 15 10 / 15 V1K55A03
AVB20200D0X0X0X1 59.4 53.5 20 15 B2 V1K80A03
AVB20250D0X0X0X1 74.8 67.3 25 20
C1AVB20300D0X0X0X1 88 79.2 30 25 V1K110A03
AVB20400D0X0X0X1 115 103.5 40 30 V1K130A03
AVB20500D0X0X0X1 143 128.7 50 C2 V1K160A03
AVB20600D0X0X0X1 170 153.0 60 V1K200A03
380-460 3
AVB40015D0X0X0X1 2.7 2.4 1.5 1
A5
V1K8A03AVB40020D0X0X0X1 3.4 3.1 2 1.5
AVB40030D0X0X0X1 4.8 4.3 3 2
AVB40050D0X0X0X1 8.2 7.4 5 3 V1K12A03
AVB40075D0X0X0X1 11 9.9 7.5 5
AVB40100D0X0X0X1 14.5 13.1 10 7.5 V1K18A03
AVB40150D0X0X0X1 21 18.9 15 10
B1
V1K25A03
AVB40200D0X0X0X1 27 24.3 20 15 V1K35A03
AVB40250D0X0X0X1 34 30.6 25 20
AVB40300D0X0X0X1 40 36.0 30 25 B2 V1K55A03
AVB40400D0X0X0X1 52 46.8 40 30
AVB40500D0X0X0X1 65 58.5 50 40
C1 V1K80A03
AVB40600D0X0X0X1 80 72.0 60 50
AVB40750D0X0X0X1 105 94.5 75 60 V1K110A03
AVB41000D0X0X0X1 130 117.0 100 75 C2 V1K130A03
AVB41250D0X0X0X1 160 144.0 125 100 V1K160A03
575 3
AVB50015D0X0X0X1 2.4 2.2 1.5 1.5
A5
V1K8A03
AVB50020D0X0X0X1 2.7 2.4 2
AVB50030D0X0X0X1 3.9 3.5 3 2
AVB50050D0X0X0X1 6.1 5.5 5 3
AVB50075D0X0X0X1 9 8.1 7.5 5
V1K12A03AVB50100D0X0X0X1 11 9.9 10 7.5
AVB50150D0X0X0X1 18 16.2 15
B1AVB50200D0X0X0X1 22 19.8 20 V1K25A03
AVB50250D0X0X0X1 27 24.3 25 V1K35A03
AVB50300D0X0X0X1 34 30.6 30
B2AVB50400D0X0X0X1 41 36.9 40 V1K55A03
AVB50500D0X0X0X1 52 46.8 50
AVB50600D0X0X0X1 62 55.8 60 C1 V1K80A03
AVB50750D0X0X0X1 83 74.7 75 V1K110A03
AVB51000D0X0X0X1 100 90.0 100 C2
AVB51250D0X0X0X1 131 117.9 125 V1K160A03
* Nominal HP values are for reference only. Size Aquavar by maximum output amps of the motor.
** dv/dt lter recommended for applications with motor leads longer than 50'. It is recommended to use the dv/dt lter with all submersible
applications.
PAGE 9
Residential Water Systems
CentriPro
SPECIFICATIONS
Ratings and Enclosures
• IP20 Open, TYPE 1, TYPE 12, TYPE 3R, TYPE 4X
• 1.5 – 125 HP (frame A – C) wall or motor mounted
• Relative humidity lower than 95% without condensation.
• Ambient temperature 14º F – 113º F (-10ºC - 45ºC). Higher temperatures can be achieved by derating the
output amperage of the drive 10% for up to 122º F (50ºC).
• At altitudes from 0 to 1000 meters (0 to 3300 feet) rated current is available. For altitudes above 1000 meters
(3300 feet) use table listed below. Maximum 3000 meters (9900 feet). (Consult factory above 3000 meters
(9900 feet)). See chart below for derate in % of output current.
Electrical Characteristics
INPUT POWER – 3 phase 380 V to 480 V ±10%
– 1 phase 200 V to 240 V ±10%
– 3 phase 200 V to 240 V ±10%
– 3 phase 525 V to 600 V ±10%
– Frequency 50 or 60 Hz, ±2Hz
OUTPUT POWER – 3 phase from 0 to Vsupply
– 0 to 120 Hz frequency
I
OUT
(%)
100
95
90
85
80
5000 1000 1500 2000 2500 3000
Altitude (meters above sea level)*
U
L
®
USC
PAGE 10
Residential Water Systems
CentriPro
COMMUNICATION OPTIONS (Repair Part Number)
Modbus TCP (9K667) DeviceNet (9K669) Pronet (9K671)
Probus (9K668) LonWorks (9K670) Ethernet IP (9K672)
BUILT-IN CONTROL CONNECTIONS
Analog input …………………………………………………………………… 2, voltage or current, direct or inverse
Programmable digital inputs …………………………………………………… 6, 2 can be used as digital outputs
Programmable analog outputs ……………………………………………………………… 1, 0-10vdc or 4 - 20 mA
Programmable relay outputs ……………………………………………………… 2, standard Form C, 240 VAC, 2 A
Auxiliary voltage …………………………………………………………………………… +24 V DC, maximum 200 mA
PUMP AND MOTOR PROTECTIONS
Motor Protections Pump Protections
Ground Fault Pump No-Flow
Motor Stall Under Pressure
Motor Over Temperature (Predictive and Sensor Based) No Water / Loss of Prime
Motor Condensation (Motor Preheat Circuit) Short-Cycle
Motor Overload (Programmable Action) Vibration (Programming Automated)
WEATHER SHIELD
The weather shield is intended to provide additional protection of outdoor rated drives when there is a risk of
snow collecting on the top of the drive or excessive rain, which could sub cool the drive, leading to internal
condensation. The weather shield is made of corrosion resistant stainless and AISI316 and is also suitable for
installation in coastal areas and marine environments.
The weather shield is also to be used if there is a risk of direct sunlight on the display, since heat generated by
the sun radiation might damage the LCD as well as limit the maximum ambient temperature.
NOTE: The weather shield should only be used together with outdoor rated drives and will not provide
sufcient protection for outdoor installation of drives not designed for this purpose.
Weather shield selection:
Frame Size Ordering Number
A4, A5, B1, B2 9K655
C1, C2 9K698
Aquavar expansion cards can be included in the drive using the smart part number on page 4.
Expansioncardscanalsobeorderedasaeldinstallableoptionusingthe"K"partnumberslisted.
PAGE 11
Residential Water Systems
CentriPro
INPUT/OUTPUT OPTIONS (Repair Part Number)
ANALOG I/O CARD (9K653)
Includes: 3 Analog IN for 0 – 10VDC
OR
0-20mA*
4-20mA*
Ni1000 Temperature Sensor
Pt1000 Temperature Sensor
3 Analog OUT for 0 – 10VDC
Battery backup for real-time clock
Used for: Providing battery backup of clock function during loss of power (real-time clock is native to the drive,
and will reset to zero during power outage without Analog I/O card.)
Extension of analog I/O on control card (multi zone with 3 sensors)
Extended PID controllers with I/O’s (set point inputs, sensor inputs and outputs)
*Requires510Ωresistor
GENERAL I/O CARD (9K654)
Includes: 3 Digital IN, 2 Digital OUT, 2 Analog IN (voltage), 1 Analog OUT (current)
Used for: Extension of number of digital and analog inputs and outputs
X30/ 1 2 3 4 5 6 7 8 9 10 11 12
COM
DIN
DIN7
DIN8
DIN9
GND(1)
GND(2)
DOUT3
AIN3
AIN4
DOUT4
AOUT2
24V
1 2 3 4 5 6 7 8 9 10 11 12
AIN
GND
AIN
GND
AIN
GND
GND
GND
AOUT
O-10VDC
AOUT
O-10VDC
AOUT
O-10VDC
GND
PAGE 12
Residential Water Systems
CentriPro
INPUT/OUTPUT OPTIONS (continued)
PTC THERMISTOR CARD (9K656)
Includes: Twelve terminal PTC card
Used for: Monitor temperature of electric motor with PTC thermistor input (PTC Thermistor Card option is
Certied for ATEX for use with motors in potentially explosive atmoshpheres.)
PT100 SENSOR INPUT CARD (9K657)
Includes: Twelve terminal PTC100 card
Used for: Sensor Input for PT100 and PT1000 temperature sensors for motor bearing temperatures
Motor protection ZIEHL
com
X44
T1
T2
NC
NC
NC
NC
NC
NC
NC
NC
DO
12345678910 11 12
11 Reference for 10, 12
10 20-28 VDC 10 mA
12 20-28 VDC 60 mA
PT 100
Sensor Input Option B
12345678910 11 12
X48/
VDD I IN GND TEMP
1
WIRE
1
GND TEMP
2
WIRE
2
GND TEMP
3
WIRE
3
GND
4-20mA
2 or 3
wire 2 or 3
wire
2 or 3
wire
2 or 3
wire
PAGE 13
Residential Water Systems
CentriPro
INPUT/OUTPUT OPTIONS (continued)
RELAY CARD (9K658)
Includes: 3 standard Form C, 240 VAC, 2 A
Used for: Extension of the number of output relays
BACKUP OPTIONS
24VDC BACKUP (9K659)
Includes: Pos and Neg Terminals for 24VDC
Used for: Interface to external 24 VDC auxiliary power supply
(Enables full LCP operation without line
voltage supplied.
Relay 7
NC
Relay 8
NC NC
Relay 9
1 2 3 4 5 6 7 8 9 10 11 12
Connection to 24V
Backup Supplier (A5-C2)
PAGE 14
Residential Water Systems
CentriPro
DISCONNECT OPTIONS
FUSED AND STANDARD (NON-FUSED) DISCONNECT
Includes: Fused disconnect enclosure includes fused disconnect in 3 phase
NEMA 1, NEMA 12 & NEMA 4X. Standard disconnect available
in single phase enclosures only.
Used for: Local disconnect of supply power to the drive.
COATING/EMC FILTER OPTIONS
3C3 BOARD COATING
Includes: Additional protection for printed circuit board (PCB) above
the standard protection to 3C2.
Used for: Aggressive environments where drive may be subject to
corrosive gases. NOTE: THIS IS NOT A SUBSITUTE FOR SIZING
THE PROPER ENCLOSURE. ENCLOSURE SHOULD BE SELECTED
BASED UPON ENVIRONMENT.
EMC OPTIONS
Includes: H2 lter (EN 55011 Class A2) standard on all models except 575V and single phase, 10, 20 and 30 HP.
575V and single phase, 10, 20 and 30 HP drives are not available with EMC lter.
Options: H1 or H3 (EN 55011 Class A1/B)
Used for: Increased level of EMC and RFI noise dampening
MOTOR MOUNTING OPTIONS
MOTOR MOUNTING
Includes: Two motor mounting plate adapters sized for motors
56C through 440 frame
Used for: Intended for motor mounting of the VFD. Requires a vertical conguration and the vertical motor to
have a mounting foot. The Aquavar with adapter plates mounts right to the motor foot!
DV/DT FILTERS* (ORDER SEPARATELY)
Includes: NEMA 3R dv/dt lter
Used for: Provides motor protection by limiting voltage spikes below
1,000 volts for long lead (submersible) applications.
FEATURES:
• 2 – 130 amps; 240V – 600V; 2 - 125HP
• NEMA 3R Enclosure
• Carrier Frequency: 1 – 12 kHz
• Fundamental Frequency: 0 – 60Hz
• Efciency: > 98%
• Insulation Rating 600V Class DV/DTltershavebeensized
in the outdoor rated Product
Charts(Page8).DV/DTlters
to be ordered separately to
mount near the drive.
• Agency Approvals: UL, cUL
• Maximum Altitude: 6,000 feet
• (Derate for applications above
6,000 feet)
* dv/dt lters are recommended
on all pumping applications with
Motor leads longer than 50’
PAGE 15
Residential Water Systems
CentriPro
Frame size
(HP): A2 A3 A4 A5 B1 B2 B3 B4 C1 C2 C3 C4
208-230V
1.5-3 51.5-3 1.5-5 7.5-15 20 7.5-15 20-25 25-40 50-60 30-40 50-60
380-460V
1.5-5
7.5-10
1.5-5
1.5-10 15-25 30-40 15-25 30-50 50-75 100-125 60-75 100-
125
575V
1.5-10 1.5-10 15-25 15-40 15-25 30-50 50-75 50-125 60-75 100-
125
Enclosure
Options
IP20
OPEN TYPE 1 IP20
OPEN TYPE 1
TYPE 12
TYPE 3R
TYPE 4X
TYPE 12
TYPE 3R
TYPE 4X
TYPE 1
TYPE 12
TYPE 3R
TYPE 4X
TYPE 1
TYPE 12
TYPE 3R
TYPE 4X
IP20
OPEN
IP20
OPEN
TYPE 1
TYPE 12
TYPE 3R
TYPE 4X
TYPE 1
TYPE 12
TYPE 3R
TYPE 4X
IP20
OPEN
IP20
OPEN
Height in (mm)
Enclosure
9.69
(246)
14.65
(372)
9.69
(246)
14.65
(372)
15.35
(390)
16.54
(420)
18.90
(480)
25.59
(650)
13.78
(350)
18.11
(460)
26.77
(680)
30.31
(770)
19.29
(490)
23.62
(600)
with
De-coupling
Plate
14.72
(374) -14.72
(374) - - - - - 16.5
(419)
23.43
(595) - - 24.8
(630)
31.5
(800)
Backplate
10.55
(268)
14.76
(375)
10.55
(268)
14.76
(375)
15.35
(390)
16.54
(420)
18.90
(480)
25.59
(650)
15.71
(399)
20.47
(520)
26.77
(680)
30.31
(770)
21.65
(550)
25.98
(660)
Distance
Between
Mounting
Holes
10.12
(257)
13.78
(350)
10.12
(257)
13.78
(350)
15.79
(401)
15.83
(402)
17.87
(454)
24.57
(624)
14.96
(380)
19.49
(495)
25.51
(648)
29.09
(739)
20.51
(521)
24.84
(631)
Width in (mm)
Enclosure
3.54
(90)
3.54
(90)
5.12
(130)
5.12
(130)
7.87
(200) 9.53 (242) 9.53 (242) 9.53 (242) 6.50
(165)
9.09
(231)
12.13
(308)
14.57
(370)
12.13
(308)
14.57
(370)
Backplate
3.54
(90)
3.54
(90)
5.12
(130)
5.12
(130)
7.87
(200) 9.53 (242) 9.53 (242) 9.53 (242) 6.50
(165)
9.09
(231)
12.13
(308)
14.57
(370)
12.13
(308)
14.57
(370)
Distance
Between
Mounting
Holes
2.76
(70)
2.76
(70)
4.33
(110)
4.33
(110)
6.73
(171) 8.46 (215) 8.27 (210) 8.27 (210) 5.51
(140)
7.87
(200)
10.71
(272)
13.15
(334)
10.63
(270)
12.99
(330)
Depth in (mm)
Without
A/B Option
Card*
8.07
(205)
8.07
(205)
8.07
(205)
8.07
(205)
6.89
(175) 7.87 (200) 10.24
(260)
10.24
(260)
9.76
(248)
9.53
(242)
12.20
(310)
13.19
(335)
13.11
(333)
13.11
(333)
With A/B
Option
Card*
8.66
(220)
8.66
(220)
8.66
(220)
8.66
(220)
6.89
(175) 7.87 (200) 10.24
(260)
10.24
(260)
10.31
(262)
9.53
(242)
12.20
(310)
13.19
(335)
13.11
(333)
13.11
(333)
Screw Holes inches (mm)
Screw Hole c
0.31 (8) 0.31 (8) 0.31 (8) 0.31 (8) 0.32 (8.2) 0.32 (8.2) 0.47 (12) 0.47 (12) 0.31
(8) -0.47 (12) 0.47 (12) - -
Screw Hole d
0.43
(11)
0.43
(11)
0.43
(11)
0.43
(11) 0.47 (12) 0.47 (12) 0.75 (19) 0.75 (19) 0.47
(12) -0.75 (19) 0.75 (19) - -
Screw Hole e
0.22
(5.5)
0.22
(5.5)
0.22
(5.5)
0.22
(5.5) 0.26 (6.5) 0.26 (6.5) 0.35 (9) 0.35 (9) 0.27
(6.8)
0.33
(8.5) 0.35 (9) 0.35 (9) 0.33
(8.5)
0.33
(8.5)
Screw Hole f
0.35 (9) 0.35 (9) 0.35 (9) 0.35 (9) 0.24 (6) 0.35 (9) 0.35 (9) 0.35 (9) 0.31
(7.9)
0.59
(15) 0.39 (9.8) 0.39 (9.8) 0.67
(17)
0.67
(17)
Max. Weight
- lb (kg)
11 (5) 12 (5.5) 15 (6.8) 16 (7.3) 22 (10) 31 (14.1) 51 (23.1) 60 (27.2) 27
(12.2)
52
(23.6) 100 (45.4) 144 (65.3) 78
(35.4)
111
(50.4)
* Depth of enclosure will vary with different options installed.
MECHANICAL DIMENSIONS
Xylem Inc.
2881 East Bayard Street Ext., Suite A
Seneca Falls, NY 13148
Phone: (800) 453-6777
Fax: (888) 322-5877
www.centripro.com
CentriPro and Aquavar are trademarks of Xylem Inc. or one of its subsidiaries.
© 2016 Xylem Inc. BCPAQIPC R3 March 2016
DIMENSIONS
Top and bottom
mounting holes
Top and bottom mounting holes
(B4 + C3 + C4 only)
A2
IP20/21*
B3
IP20/21*
C3
IP20/21*
B4
IP20/21*
C4
IP20/21*
A3
IP20/21*
A4
IP55/66
TYPE 12/4X
A5
IP55/66
TYPE 3R/12/4X
B1
IP21/55/66
B2
IP21/55/66
C1
IP21/55/3R/66
C2
IP21/55/3R/66
OPEN/TYPE 1
OPEN/TYPE 1 OPEN/TYPE 1TYPE 1/3R/12/4X
TYPE 1/3R/12/4X