SECTION: 2.60.055

Your Peace of Mind is Our Top Priority ®

FM2826
0114
Supersedes
New

®

Product information presented
of publication. Consult factory
regarding discrepancies or
inconsistencies.

MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

visit our web site:
www.zoeller.com

Model 508

12 Volt Backup Sump Pump System
“The submersible sump pump worthy of
the Aquanot® Name”

APPLICATION:

For clear water, emergency backup usage during interruption of AC power or
because of primary pump(s) failure or insufficient capacity.

FEATURES:

Designed using Zoeller's time-tested components giving you the needed
performance and reliability.

BILGE
PUMP

PUMP:
•	 12 volt highly efficient noncorrosive pump construction. Supplied with 6' leads.
•	 NOT a Bilge pump. Designed, Engineered and Assembled by Zoeller as a
sump pump
•	 Integrated check valve
•	 Legs allow free standing installation
•	 Quick disconnect discharge
•	 Aluminum seal pocket & cooling plate
•	 Hand built & 100% tested in USA
•	 Efficient design means more water pumped during emergencies.

PRIMARY SUMP PUMP
NOT INCLUDED WITH MODEL 508

CONTROL BOX: Includes battery burn-out and overcharge protection. The self contained
10 amp battery recharger system is a solid state automatic controller with alarms, light
indicators and warning systems.
LCD SCREEN: Always displays battery voltage along with other helpful information
about the system.
LED LIGHT INDICATORS:
• AC Power - blinks red when power is out
• Charged - green indicates battery is fully charged
• Charging - yellow indicates power is going to battery
• Low Battery - red light blinks when below 10.8 volts and rapidly blinks when 	
below 8.4 volts
• High Water - yellow light will blink when the float is activated, and becomes 	
solid after 3 seconds
• Alarm Off - yellow light indicates the buzzer is currently silenced
ALARMS:
• High Water • Reverse Polarity

• Low Battery

BUTTONS:
• Scroll - display information on the system such as DC pump cycles and power 	
outages
• Alarm Reset - press to reset alarms. Press and hold for three seconds for 	
24-hour buzzer silence
AUXILIARY ALARM CONTACT: A set of dry contacts allows system to connect to
home security alarm, auto dialers, etc.
SWITCH: Reliable, low voltage vertical float switch
BATTERY CASE: The included battery case will accommodate maximum battery
dimensions of 13" L x 7-1/2" W x 9-1/2" H and fits all group size 27, 29 and 31 batteries.
Made from noncorrodible polyethylene. To use multiple batteries, order extra battery
case with hookup wire (P/N 007861).

Product may not be exactly as shown. For preassembled systems,
order a Pro Pak.

FITTINGS: An integrated DC pump discharge check valve, additional AC
pump check valve, tee, and adapter are included.
TECHNOLOGY: This charger uses the latest switch mode technology
available. This allows for an extremely efficient charger in a compact
design. It satisfies the rigid California Battery Council standards. BC
Charger is also C US approved.

© Copyright 2014 Zoeller Co. All rights reserved.

Model 508

Aquanot® Deep-cycle

Battery (purchase separately)

P/N 10-1450 - AGM (shown)
P/N 10-0761 - Wet

WARRANTY - 12-months from date of installation or 18-months from date of manufacture. However the 12-month warranty is
extended to 36-months with the purchase of an Aquanot ® Battery by Zoeller. NOTE: Three-year limited warranty is valid only when a
complete system is purchased and used as a backup to a primary dewatering system. A complete system includes a Model 508 and
an Aquanot ® Battery.

BATTERY LIFE - The estimated life of a fully charged (175 minute reserve capacity) battery when the pump is operating continuously

is approximately 5½ hours. Example: the pump's capacity at 10 ft. head is 1800 GPH (30 GPM). Most backup systems require intermittent
pump operation.The system will provide protection for extended periods of time dependent upon stop-start requirements.

PERFORMANCE DATA - Pump performance is based on the use of a fully charged 12 volt, (200-minute reserve capacity)
deep-cycle battery with no deficiency and less than two years old.

AQUANOT ® BATTERY

•
•

Size 31 “Wet” P/N 10-0761 (69 lbs.) (shipped via truckline only)
200 minute reserve capacity
Minimum battery requirements:
Size 27 “AGM” P/N 10-1450 (66 lbs.)
deep-cycle, size 27, 175 minute
175-minute reserve capacity

METERS
TOTAL DYNAMIC HEAD

8

6

4

FEET

reserve capacity.

PUMP PERFORMANCE CURVE
MODELS 508

TOTAL DYNAMIC HEAD/FLOW
PER MINUTE
EFFLUENT AND DEWATERING

25
20
15
10

2

MODEL

508

Feet
Meters
5
1.5
10
3.0
15
4.6
20
6.1
Shut-off Head:

Gal.
Liters
39
148
30
114
20
76
6
23
22ft. (6.7m)

5

based upon actual performance
achieved with a 12 volt deep-cycle
battery. Some manufacturers
publish performance data based
upon D.C. Pump testing according
to Marine Industry standards
which can reflect a performance
of 40% - 80% higher than actual
battery powered performance.

152944

Minimum pit size requirements: 18" diameter X 24" deep.
For 18" x 22" applications, consult factory.

0
10

GALLONS
LITERS

NOTE: Performance chart

0

20

30

80
FLOW PER MINUTE

40

50

160

Shipping weight: 17 lbs.
NOTE: Not recommended for installation with over 20 ft. Total Dynamic Head.
CAUTIONS: See FM2769 (Model 508) Installation Instructions.

®

MAIL TO: P.O. BOX 16347 • Louisville, KY 40256-0347
SHIP TO: 3649 Cane Run Road • Louisville, KY 40211-1961
(502) 778-2731 • 1 (800) 928-PUMP • FAX (502) 774-3624

Your Peace of Mind is Our Top Priority ®
© Copyright 2014 Zoeller Co. All rights reserved.

visit our web site:
www.zoeller.com



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.4
Linearized                      : Yes
Tagged PDF                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.6-c015 84.159810, 2016/09/10-02:41:30
Create Date                     : 2014:01:08 08:42:47-05:00
Modify Date                     : 2017:01:23 11:16:12-05:00
Metadata Date                   : 2017:01:23 11:16:12-05:00
Creator Tool                    : Adobe InDesign CS6 (Windows)
Version ID                      : 1
Instance ID                     : uuid:e543efab-deba-425c-ab7f-91e74ea98ed6
Original Document ID            : adobe:docid:indd:a1c60291-7040-11dc-add0-ed2c4ae1c339
Document ID                     : xmp.id:A04E4A556978E3119CA1AC1BB46F2532
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:9F4E4A556978E3119CA1AC1BB46F2532
Derived From Document ID        : xmp.did:0EB420823B63E3119CF288F41A17B0F8
Derived From Original Document ID: adobe:docid:indd:a1c60291-7040-11dc-add0-ed2c4ae1c339
Derived From Version ID         : 1
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CS6 (Windows)
History Changed                 : /
History When                    : 2014:01:08 08:42:47-05:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 10.0.1
Trapped                         : False
Page Count                      : 2
Creator                         : Adobe InDesign CS6 (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu