548368 2 SJE Rhombus 122 Control Panel Specifications
548359 2 Sje Rhombus 122 Control Panel Specifications 548359_2_SJE Rhombus 122 Control Panel Specifications
548369 2 Sje Rhombus 122 Control Panel Specifications 548369_2_SJE Rhombus 122 Control Panel Specifications
551166 1 Sje-Rhombus 122 Single Phase Duplex Motor Contactor Control Specifications 551166_1_SJE-Rhombus 122 Single Phase Duplex Motor Contactor Control Specifications
548358 2 Sje Rhombus 122 Control Panel Specifications 548358_2_SJE Rhombus 122 Control Panel Specifications 548358_2_SJE Rhombus 122 Control Panel Specifications pdf pumpproducts
: Pump 548368 2 Sje Rhombus 122 Control Panel Specifications 548368_2_SJE Rhombus 122 Control Panel Specifications pdf
Open the PDF directly: View PDF .
Page Count: 2
Download | |
Open PDF In Browser | View PDF |
MODEL 122 Control Panel Single phase, duplex alternating pump control with override. The Model 122 control panel is designed to alternately control two 120, 208, or 240 VAC single phase pumps in water and sewage installations. The alternating action equalizes pump wear. In addition to the alternating pump control, this system provides override control should either pump fail. If an alarm condition occurs, an alarm switch activates the audio/visual alarm system. Common applications include pump chambers, sump pump basins, irrigation systems and lift stations. PANEL COMPONENTS 1. Enclosure measures 10 X 10 X 6 inches (25.4 X 25.4 X 15.24 cm). Choice of NEMA 1 (steel for indoor use), or NEMA 4X (ultraviolet stabilized 3 thermoplastic with removable mounting feet for outdoor or indoor use). Note: Options selected may increase enclosure size and change component 1 layout. 2. Magnetic Motor Contactors control pumps by switching electrical lines. 3. HOA Switches for manual pump control (mounted on circuit board). 4. Control Circuit Board provides pump control and alternation. 5. Green pump Run Indicator Lights (mounted on circuit board). 14 10 5 4 panel cover 9 8 6. Circuit Breakers (optional) provide pump disconnect and branch circuit protection. 7. Ground Lugs 11 2 6 8. Float Status Indicator Lights (mounted on circuit board). 9. Control and Alarm Power Indicator Lights (mounted on circuit board) 10. Auxiliary Alarm Contact, form C (mounted on circuit board). NOTE: Schematic is located inside the panel on enclosure cover. STANDARD ALARM PACKAGE 11. Red Alarm Beacon provides 360° visual check of alarm condition. Note: NEMA 1 style utilizes a door mounted indicator in lieu of a beacon. 12. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel rating). Note: NEMA 1 style utilizes an internally mounted buzzer in lieu of horn. 13 12 7 7 Model Shown 1221W114X6A 13. Exterior Alarm Test/Normal/Silence Switch allows horn and light to be tested and horn to be silenced in an alarm condition. Alarm automatically resets once alarm condition is cleared. 14. Horn Silence Relay (mounted on circuit board). NOTE: other options available. FEATURES n Entire control system (panel and switches) is UL Listed to meet and/or exceed industry safety standards n Dual safety certification for the United States and Canada n Standard package includes three 20' SJE SignalMaster® control switches n Complete with step-by-step installation instructions n Five-year limited warranty SEE BACKSIDE FOR COMPLETE LISTING OF AVAILABLE OPTIONS. SEE PRICE BOOK FOR LIST PRICE. PO Box 1708, Detroit Lakes, MN 56502 1-888-DIAL-SJE • 1-218-847-1317 1-218-847-4617 Fax email: customer.service@sjerhombus.com www.sjerhombus.com B.41 122 6A MODEL 122 ALARM PACKAGE 0 = select options or no alarm package 1 = alarm package (includes test/normal/silence switch, fuse, red light, & horn) ENCLOSURE RATING I = Indoor, NEMA 1 (metal) W = Weatherproof, NEMA 4X (engineered thermoplastic) STARTING DEVICE 1 = magnetic motor contactor 120/208/240V 9 = magnetic motor contactor 120V only PUMP FULL LOAD AMPS 0 1 2 3 = 0-7 FLA = 7-15 FLA = 15-20 FLA = 20-30 FLA PUMP DISCONNECTS 0 = no pump disconnect 4 = circuit breaker 120V (select STARTING DEVICE option 9 above) 120/208/240V (select STARTING DEVICE option 1 above) FLOAT SWITCH APPLICATION H or L = pump down or pump up (select 17 option) X = no floats OPTIONS Listed below H ENCLOSURE UPSIZE If you selected one or more of the H options, or two HH options CODE DESCRIPTION CODE 1A Red beacon only / no audio (must select "0" for alarm package) 1C Horn only / no visual (must select "0" for alarm package) HH 3A Alarm flasher H 3B Manual alarm reset H 4A Redundant off (select Option 4D if floats included) 4B Red redundant off indicator & alarm (must select Option 4A also) 4D Redundant off float (must select 4A option) (select 17 option) H 5A Thermal cutout/heat sensor auto reset (for pumps w/thermal switch leads) H 5E Seal failure circuit & red indicator (2 wire) 6A Auxiliary alarm contact, form C (included as standard) H 8A Elapsed time meter H 8C Event (cycle) counter H 9_A Pump overload specify amperage after number 9 followed by letter "A". ... Example: 912A = 12 amp pump. H 0-25 FLA H 25-30 FLA 10E Lockable latch - NEMA 4X 10E Lockable latch - NEMA 1 H 10F Lightning arrestor (select pump circuit breaker) DESCRIPTION HH 10K Anti-condensation heater 11C NEMA 1 alarm panel 11D NEMA 4X alarm panel H 14B Main disconnect (rotary style, mounted through door, non-fused, padlockable in the OFF-position, door interlock in the ON-position) (must select circuit breaker) H 0-20 FLA (total of both pumps) H 20-60 FLA (total of both pumps) 16A 10' cord in lieu of 20' (per float) 16B 15' cord in lieu of 20' (per float) 16C 30' cord in lieu of 20' (per float) 16D 40' cord in lieu of 20' (per float) 17A SJE SignalMaster® / pipe clamp l (per float) 17B SJE SignalMaster® / externally weighted l (per float) 17C Sensor Float® / internally weighted s (per float) 17D Sensor Float® / externally weighted s (per float) 17E Sensor Float® Mini / pipe clamp s (per float) 17F Sensor Float® Mini / externally weighted s (per float) 17J Sensor Float® / pipe clamp s (per float) 19B Lead lag selector switch 19F Fourth float to separate alarm function from lag 19T TOA (Test/Off/Automatic) switches and pump run lights through door mounted 19U HOA (Hand/Off/Automatic) switches and pump run lights through door mounted 19X Door mounted pump run indicator l Mechanically-activated Mercury-activated If additional features are required, call the factory for a quote on an Engineered Custom control panel. SAMPLE MODEL 122 1 W 9 0 4 H 6A 8AC 17A Alarm Package Enclosure Rating Starting Device Pump Full Load Amps Pump Disconnect Float Switch Application Options: Auxiliary alarm contact, form C, Elapsed time meter, event (cycle) counter, SJE SignalMaster® / pipe clamp B.42 9500066B © SJE-Rhombus 12/16
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes Language : en-US XMP Toolkit : Adobe XMP Core 5.6-c123 79.158978, 2016/02/13-01:11:19 Create Date : 2017:01:18 11:41:46-06:00 Metadata Date : 2017:01:18 11:41:46-06:00 Modify Date : 2017:01:18 11:41:46-06:00 Creator Tool : Adobe InDesign CC 2015 (Windows) Instance ID : uuid:dfc1935f-2f92-46ff-acde-10b7f21583d6 Original Document ID : xmp.did:05938658C23EE01187C0F6D4CCEA3A82 Document ID : xmp.id:cd3aa022-ea52-954f-954b-0e5792eeece3 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:2b6a61d0-ddca-6e47-9bf7-dd9192f3faff Derived From Document ID : xmp.did:bdbc3176-be85-f443-a5cc-a6eb279563ea Derived From Original Document ID: xmp.did:05938658C23EE01187C0F6D4CCEA3A82 Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC 2015 (Windows) History Changed : / History When : 2017:01:18 11:41:46-06:00 Format : application/pdf Producer : Adobe PDF Library 15.0 Trapped : False Page Count : 2 Creator : Adobe InDesign CC 2015 (Windows)EXIF Metadata provided by EXIF.tools