Single phase, simplex subsurface drip irrigation panel for pump control and system monitoring.
The Installer Friendly Series® Drip irrigation control panel is designed to control one 120V or 230V single phase pump for subsurface
irrigation systems. The IFS Drip panel features a simple, easy-to-use touch pad on the inner door for programming and monitoring
system operation: rest for standard time, rest for peak enable time, spin lter ush time, dose time, eld ush time, eld drain time,
and low alarm activation.
Installer Friendly Series® Drip Control Panel
SEE PRICE BOOK FOR LIST PRICE.
1. NEMA 4X enclosure ultraviolet stabilized thermoplastic with removable
mounting feet for outdoor or indoor use measures 12 x 10 x 6 inches (30.48
x 25.40 x 15.24 cm).
2. Red Alarm Beacon provides 360o visual check of alarm condition.
3. Exterior Alarm Test/Normal/Silence Switch allows horn and beacon to be
tested and horn to be silenced in an alarm condition. Alarm automatically
resets once alarm condition is cleared.
4. Alarm Horn provides audio warning of alarm condition (83 to 85 decibel
rating).
5. Circuit Breaker provides pump disconnect and branch circuit protection.
6. Circuit Board provides power to main circuit board and contains terminal
blocks for oat and valve connections.
7. Float Connections
8. Valve Connections
9. Magnetic Motor Contactor controls pump by switching electrical lines.
10. Large Incoming Power/Pump Connection Terminal Block
11. Ground Lugs
NOTE: Schematic/Wiring Diagram, Pump Specication Label, Input Display Code
Label, and Counter Display Code Label are on inside cover for viewing/programming
digital display.
FEATURES
n
Entire control system (panel and
switches) is UL Listed to meet and/or
exceed industry safety standards
n
Dual safety certication for the United
States and Canada
n
Standard package includes four
control switches
n
Optional pressure switch for aerobic
applications.
n
Complete with step-by-step installation
instructions
n
Five-year limited warranty
A. Alarm Power Indicator/Fuse. LED indicator light illuminates if alarm power
is present in panel.
B. Alarm Power Replace Indicator illuminates if alarm fuse is blown.
C. Control Power Indicator/Fuse. LED indicator light illuminates if control power
is present in panel.
NOTE: If control power is not present panel will go into alarm mode.
D. HOA (Hand/Off/Automatic) Indicators/Buttons control pump mode with
LED indication.
E. Float Status Indicators illuminate when oats are activated. Alarm will activate
and indicator will ash if a oat operates out of sequence.
F. Pump Run Indicator illuminates when pump is called to run.
G. Cycle Status Indicators allows user to see which cycle (dose, ush, or drain)
is activated.
H. Advance and Pause Buttons allow user to cycle though system functions
for testing.
I. Rest Time Indicator illuminates in between cycles.
J. Count Indicator illuminates when viewing panel data.
K. Program Indicator illuminates when programming panel.
L. Flush Valve Indicator illuminates when ush valve is called to energize.
M. Spin Valve Indicator illuminates when spin valve is called to energize.
N. Seven-Segment LED Display shows high water alarm count, oat status
sequence error count, low level cutout oat open low alarm count, standard
dose count, power-fail count, pump on/off cycle count, pump run times (hh:mm),
and peak does count.
O. Next, Up, Select Buttons are used to navigate through the display.
NOTE: LED display will turn off after one minute of not being used.
B.27
PANEL COMPONENTS
TOUCH PAD FEATURES
A
D
B
E
N
F
C
I
G
J
M
H
L
K
2
6
7
4
8
31
5
9
11
10
O
Installer Friendly Series® Drip Control Panel
IFS Drip Control Panel Operation:
Four (4) oat switches (low level, timer on/off, peak enable, and high alarm oats) control the operation. Timers internal to the PCB
control the pump dosing cycles. When the liquid level activates the timer on oat, the following operations occur:
1. Rest time
2. The pump turns on and the spin lter valve opens for the user-programmed length of time.
3. The spin lter valve closes and the pump continues to run for the user-programmed dose time.
4. The pump continues to run and the ush valve opens for the user-programmed length of time.
5. The pump turns off and the ush valve remains open for the user-programmed drain time.
6. The ush valve closes for the user-programmed off time.
Call or fax your order!
1-888-DIAL-SJE (1-888-342-5753) n Fax 218-847-4617 www.sjerhombus.com
customer.service@sjerhombus.com
9500081B
© SJE-Rhombus 12/16
B.28
Product offering and pricing are subject to change without notice.
Please visit www.sjerhombus.com for the most current information.