550505 3 SJE Rhombus PS Patrol Alarm System Installation Instructions
550506 3 Sje Rhombus Ps Patrol Alarm System Installation Instructions 550506_3_SJE Rhombus PS Patrol Alarm System Installation Instructions 550506_3_SJE Rhombus PS Patrol Alarm System Installation Instructions pdf pumpproducts
: Pump 550505 3 Sje Rhombus Ps Patrol Alarm System Installation Instructions 550505_3_SJE Rhombus PS Patrol Alarm System Installation Instructions pdf
Open the PDF directly: View PDF .
Page Count: 4
Download | |
Open PDF In Browser | View PDF |
PS Patrol® System with 120V Alarm Installation Instructions POWER ON SYSTEM MO N IT O RIN G This control panel must be installed and serviced by a licensed electrician in accordance with the National Electric Code NFPA-70, state and local electrical codes. Installation Instructions Figure 1 Figure 2 Figure 3 3.5 inch (9 cm) minimum tether length Install alarm float and pump float. (Mounting Clamp detail) Wide angle* float system. SJE Double Float® Master and Double Float® pump switches *SJE PumpMaster®, SJE PumpMaster® Plus, or Super Single® pump switches DETERMINING PUMPING RANGE (IN INCHES) Super Single® pumping range tether length pumping range 3.5 6.5 5 7.5 7 8.5 9 10 11 13 15 11 12.5 13.5 SJE PumpMaster® & SJE PumpMaster Plus® pumping range tether length pumping range 3.5 7 6 10 10 16 9 22 14 28 18 33 22 36 Use only as a guide. Pumping ranges are based on testing in non-turbulent conditions. Range may vary due to water temperature and cord shape. Note: As the tether length increases, so does the variance of the pumping range. 22650 County Highway 6 n P.O. Box 1708 n Detroit Lakes, Minnesota 56502 USA 1-888-DIAL-SJE (1-888-342-5753) n Phone: 218-847-1317 n Fax: 218-847-4617 E--mail: customer.service@sjerhombus.com n Website: www.sjerhombus.com ©SJE-Rhombus PN1039317A • Rev 10/14 Installation Instructions Figure 4 Post Riser mounting kit (optional) Pump power cord, alarm float cable, and pump float cable Pump power, alarm power, and optional auxiliary alarm cable Run cables through optional riser mounting kit and post. Figure 6 Figure 5 Alarm float cable Pump cable Pump switch cable PSP cord receptacle Punch out power cable knock outs as shown. Note: Only remove knock outs for number of cables used. Holding base, run cables through cord seal holes. Figure 7 Figure 8 Post (optional) Conduit/ PVC pipe (customer supplied) Mount PS Patrol® to post. Note: PS Patrol® can be mounted to optional square plastic post as shown in Figure 7 or 4 inch conduit / PVC Pipe (customer supplied) as shown in Figure 8. Use #8 x 1" screws only. Installation Instructions Figure 9 Figure 10 Incoming alarm power Duct seal Incoming pump power Alarm float switch L1 N G Use electrical duct seal to fill around incoming power cords. Ensure pocket is filled completely and the gaps filled around each cable. Connect alarm power, pump power and alarm float switch as shown. WARNING: Failure to do so will allow sewer gases to enter control panel causing corrosion and failure of electrical components. Figure 11 Figure 12 ETM (optional) snaps into base PSP cord receptacle Pump plug Pump switch plug ETM (optional) Plug pump switch piggy-back plug into PSP cord receptacle. If using optional ETM, plug this into back of pump switch piggy-back plug. Plug pump in last. WARNING: Failure to have the plugs in order described as shown will effect proper operation of system. Figure 13 Fill unused holes in cord seal with PVC dowels PSP receptacle fits into pocket If ETM is used, snap into location as shown. Arrange cords as shown. Receptacle is inserted into pocket. Push excess cord back through cord seal. Install PVC dowels into unused holes of cord seal. Figure 14 Cord seal nut Firmly tighten cord seal nut so that cables do not move and cord seal is held in place. Install cover on base and screw into place. Installation Instructions Figure 16 Figure 15 Power On Indicator Push to test Alarm float Pump float Turn on power and test alarm by pressing the test silence switch. Horn will sound and alarm light will illuminate. Perform final testing on system by lifting pump and alarm float. When pump float is lifted, the pump will turn on. When alarm float is lifted, the alarm horn will sound and alarm light will illuminate. SJE-Rhombus® Five-Year Limited Warranty SJE-RHOMBUS® warrants to the original consumer that this product shall be free of manufacturing defects for five years after the date of consumer purchase. During that time period and subject to the conditions set forth below, SJERHOMBUS® will repair or replace, for the original consumer, any component which proves to be defective due to defective materials or workmanship of SJE-RHOMBUS®. Some states do not allow limitations on how long an implied warranty lasts, so the above limitation may not apply to you. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This warranty gives you specific legal rights, and you may also have other rights which vary from state to state. ELECTRICAL WIRING AND SERVICING OF THIS PRODUCT MUST BE PERFORMED BY A LICENSED ELECTRICIAN. TO OBTAIN WARRANTY SERVICE: The consumer shall assume all responsibility and expense for removal, reinstallation, and freight. Any item to be repaired or replaced under this warranty must be returned to SJE-RHOMBUS®, or such place as designated by SJE-RHOMBUS®. THIS WARRANTY DOES NOT APPLY: (A) to damage due to lightning or conditions beyond the control of SJERHOMBUS®; (B) to defects or malfunctions resulting from failure to properly install, operate or maintain the unit in accordance with printed instructions provided; (C) to failures resulting from abuse, misuse, accident, or negligence; (D) to units which are not installed in accordance with applicable local codes, ordinances, or accepted trade practices, and (E) to units repaired and/or modified without prior authorization from SJE-RHOMBUS®. ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS ARE LIMITED TO THE DURATION OF THIS WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT, IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL OR CONSEQUENTIAL DAMAGES AS A RESULT OF A BREACH OF THIS WRITTEN WARRANTY OR ANY IMPLIED WARRANTY. NOTICE! Products returned must be cleaned, sanitized, or decontaminated as necessary prior to shipment to ensure that employees will not be exposed to health hazards in handling said material. All applicable laws and regulations shall apply.
Source Exif Data:
File Type : PDF File Type Extension : pdf MIME Type : application/pdf PDF Version : 1.5 Linearized : Yes XMP Toolkit : Adobe XMP Core 5.5-c021 79.154911, 2013/10/29-11:47:16 Create Date : 2014:11:03 12:00:32-06:00 Metadata Date : 2014:11:03 12:00:40-06:00 Modify Date : 2014:11:03 12:00:40-06:00 Creator Tool : Adobe InDesign CC (Windows) Instance ID : uuid:e7960835-36e2-4aa1-9d59-0bcbe4c62282 Original Document ID : xmp.did:9EBEA258F86DE1119713D8F96049CF7C Document ID : xmp.id:2d443613-aa79-de4e-a8c3-ae93eabf11b9 Rendition Class : proof:pdf Derived From Instance ID : xmp.iid:c23a54c2-9147-4b41-8cef-fd2eb6bf4215 Derived From Document ID : xmp.did:780c7f99-1c59-e84d-8f15-a23cf302ef22 Derived From Original Document ID: xmp.did:9EBEA258F86DE1119713D8F96049CF7C Derived From Rendition Class : default History Action : converted History Parameters : from application/x-indesign to application/pdf History Software Agent : Adobe InDesign CC (Windows) History Changed : / History When : 2014:11:03 12:00:33-06:00 Format : application/pdf Producer : Adobe PDF Library 11.0 Trapped : False Page Count : 4 Creator : Adobe InDesign CC (Windows)EXIF Metadata provided by EXIF.tools