PS Patrol® System with 120V Alarm
Installation Instructions
POWER
ON

SYSTEM
MO

N IT O RIN

G

This control panel must be installed
and serviced by a licensed electrician in accordance with the National
Electric Code NFPA-70, state and
local electrical codes.

Installation Instructions
Figure 1

Figure 2

Figure 3

3.5 inch (9 cm)
minimum tether
length

Install alarm float and pump float.
(Mounting Clamp detail)

Wide angle* float system.

SJE Double Float® Master and Double
Float® pump switches

*SJE PumpMaster®, SJE PumpMaster® Plus,
or Super Single® pump switches

DETERMINING PUMPING RANGE (IN INCHES)
Super Single®
pumping range

tether length
pumping range

3.5
6.5

5
7.5

7
8.5

9
10

11 13
15
11 12.5 13.5

SJE PumpMaster® &
SJE PumpMaster Plus®
pumping range

tether length
pumping range

3.5
7

6
10

10
16

9
22

14
28

18
33

22
36

Use only as a guide. Pumping ranges are based on testing in non-turbulent conditions.
Range may vary due to water temperature and cord shape.
Note: As the tether length increases, so does the variance of the pumping range.

22650 County Highway 6 n P.O. Box 1708 n Detroit Lakes, Minnesota 56502 USA
1-888-DIAL-SJE (1-888-342-5753) n Phone: 218-847-1317 n Fax: 218-847-4617
E--mail: customer.service@sjerhombus.com n Website: www.sjerhombus.com

©SJE-Rhombus
PN1039317A • Rev 10/14

Installation Instructions
Figure 4
Post
Riser mounting kit
(optional)

Pump power cord,
alarm float cable,
and pump float cable

Pump power, alarm
power, and optional
auxiliary alarm cable

Run cables through optional riser mounting kit and post.

Figure 6

Figure 5

Alarm
float cable

Pump
cable

Pump
switch
cable
PSP
cord
receptacle
Punch out power cable knock outs as shown.
Note: Only remove knock outs for number of cables used.

Holding base, run cables through cord seal holes.

Figure 7

Figure 8

Post
(optional)

Conduit/
PVC pipe
(customer supplied)

Mount PS Patrol® to post. Note: PS Patrol® can be mounted to optional square plastic post as shown in Figure 7 or 4
inch conduit / PVC Pipe (customer supplied) as shown in Figure 8. Use #8 x 1" screws only.

Installation Instructions
Figure 9

Figure 10
Incoming
alarm power
Duct
seal

Incoming
pump
power

Alarm
float
switch

L1
N
G

Use electrical duct seal to fill around incoming power cords. Ensure
pocket is filled completely and the gaps filled around each cable.

Connect alarm power, pump power and alarm
float switch as shown.

WARNING: Failure to do so will allow sewer gases to enter
control panel causing corrosion and failure of electrical components.
Figure 11

Figure 12
ETM (optional)
snaps into base

PSP
cord
receptacle

Pump
plug

Pump
switch
plug

ETM
(optional)
Plug pump switch piggy-back plug into PSP cord
receptacle. If using optional ETM, plug this into back
of pump switch piggy-back plug. Plug pump in last.
WARNING: Failure to have the plugs in order described
as shown will effect proper operation of system.
Figure 13

Fill
unused
holes
in cord
seal
with
PVC
dowels

PSP receptacle
fits into pocket

If ETM is used, snap into location as shown. Arrange cords as
shown. Receptacle is inserted into pocket. Push excess cord back
through cord seal. Install PVC dowels into unused holes of cord seal.
Figure 14

Cord
seal
nut

Firmly tighten cord seal nut so that cables do not
move and cord seal is held in place.

Install cover on base and screw into place.

Installation Instructions
Figure 16

Figure 15

Power On
Indicator
Push to test
Alarm
float
Pump
float
Turn on power and test alarm by pressing the
test silence switch. Horn will sound and alarm
light will illuminate.
Perform final testing on system by lifting pump
and alarm float. When pump float is lifted, the pump
will turn on. When alarm float is lifted, the alarm
horn will sound and alarm light will illuminate.

SJE-Rhombus® Five-Year Limited Warranty
SJE-RHOMBUS® warrants to the original consumer that
this product shall be free of manufacturing defects for five
years after the date of consumer purchase. During that time
period and subject to the conditions set forth below, SJERHOMBUS® will repair or replace, for the original consumer,
any component which proves to be defective due to defective
materials or workmanship of SJE-RHOMBUS®.

Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to
you. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation
or exclusion may not apply to you. This warranty gives you
specific legal rights, and you may also have other rights
which vary from state to state.

ELECTRICAL WIRING AND SERVICING OF THIS
PRODUCT MUST BE PERFORMED BY A LICENSED
ELECTRICIAN.

TO OBTAIN WARRANTY SERVICE: The consumer
shall assume all responsibility and expense for removal,
reinstallation, and freight. Any item to be repaired or replaced
under this warranty must be returned to SJE-RHOMBUS®,
or such place as designated by SJE-RHOMBUS®.

THIS WARRANTY DOES NOT APPLY: (A) to damage
due to lightning or conditions beyond the control of SJERHOMBUS®; (B) to defects or malfunctions resulting from
failure to properly install, operate or maintain the unit in
accordance with printed instructions provided; (C) to failures
resulting from abuse, misuse, accident, or negligence; (D) to
units which are not installed in accordance with applicable
local codes, ordinances, or accepted trade practices, and (E)
to units repaired and/or modified without prior authorization
from SJE-RHOMBUS®.

ANY IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS ARE LIMITED TO THE DURATION OF THIS
WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT,
IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES AS A RESULT OF
A BREACH OF THIS WRITTEN WARRANTY OR ANY
IMPLIED WARRANTY.

NOTICE!

Products returned must be cleaned, sanitized, or decontaminated as necessary prior to shipment to ensure that employees
will not be exposed to health hazards in handling said material. All applicable laws and regulations shall apply.



Source Exif Data:
File Type                       : PDF
File Type Extension             : pdf
MIME Type                       : application/pdf
PDF Version                     : 1.5
Linearized                      : Yes
XMP Toolkit                     : Adobe XMP Core 5.5-c021 79.154911, 2013/10/29-11:47:16
Create Date                     : 2014:11:03 12:00:32-06:00
Metadata Date                   : 2014:11:03 12:00:40-06:00
Modify Date                     : 2014:11:03 12:00:40-06:00
Creator Tool                    : Adobe InDesign CC (Windows)
Instance ID                     : uuid:e7960835-36e2-4aa1-9d59-0bcbe4c62282
Original Document ID            : xmp.did:9EBEA258F86DE1119713D8F96049CF7C
Document ID                     : xmp.id:2d443613-aa79-de4e-a8c3-ae93eabf11b9
Rendition Class                 : proof:pdf
Derived From Instance ID        : xmp.iid:c23a54c2-9147-4b41-8cef-fd2eb6bf4215
Derived From Document ID        : xmp.did:780c7f99-1c59-e84d-8f15-a23cf302ef22
Derived From Original Document ID: xmp.did:9EBEA258F86DE1119713D8F96049CF7C
Derived From Rendition Class    : default
History Action                  : converted
History Parameters              : from application/x-indesign to application/pdf
History Software Agent          : Adobe InDesign CC (Windows)
History Changed                 : /
History When                    : 2014:11:03 12:00:33-06:00
Format                          : application/pdf
Producer                        : Adobe PDF Library 11.0
Trapped                         : False
Page Count                      : 4
Creator                         : Adobe InDesign CC (Windows)
EXIF Metadata provided by EXIF.tools

Navigation menu