550505 3 SJE Rhombus PS Patrol Alarm System Installation Instructions
550506 3 Sje Rhombus Ps Patrol Alarm System Installation Instructions 550506_3_SJE Rhombus PS Patrol Alarm System Installation Instructions 550506_3_SJE Rhombus PS Patrol Alarm System Installation Instructions pdf pumpproducts
: Pump 550505 3 Sje Rhombus Ps Patrol Alarm System Installation Instructions 550505_3_SJE Rhombus PS Patrol Alarm System Installation Instructions pdf
Open the PDF directly: View PDF .
Page Count: 4
PS Patrol® System with 120V Alarm
Installation Instructions
22650 County Highway 6
n
P.O. Box 1708
n
Detroit Lakes, Minnesota 56502 USA
1-888-DIAL-SJE (1-888-342-5753)
n
Phone: 218-847-1317
n
Fax: 218-847-4617
E--mail: customer.service@sjerhombus.com
n
Website: www.sjerhombus.com ©SJE-Rhombus
PN1039317A • Rev 10/14
S
Y
S
T
E
M
M
O
N
I
T
O
R
I
N
G
POWER
ON
Installation Instructions
This control panel must be installed
and serviced by a licensed electri-
cian in accordance with the National
Electric Code NFPA-70, state and
local electrical codes.
Install alarm oat and pump oat.
(Mounting Clamp detail)
Figure 1 Figure 2 Figure 3
3.5 inch (9 cm)
minimum tether
length
Wide angle* oat system.
*SJE PumpMaster®, SJE PumpMaster® Plus,
or Super Single® pump switches
SJE Double Float® Master and Double
Float® pump switches
DETERMINING PUMPING RANGE (IN INCHES)
Use only as a guide. Pumping ranges are based on testing in non-turbulent conditions.
Range may vary due to water temperature and cord shape.
Note: As the tether length increases, so does the variance of the pumping range.
tether length 3.5 5 7 9 11 13 15
pumping range 6.5 7.5 8.5 10 11 12.5 13.5
tether length 3.5 6 10 9 14 18 22
pumping range 7 10 16 22 28 33 36
Super Single®
pumping range
SJE PumpMaster® &
SJE PumpMaster Plus®
pumping range
Installation Instructions
Mount PS Patrol® to post. Note: PS Patrol® can be mounted to optional square plastic post as shown in Figure 7 or 4
inch conduit / PVC Pipe (customer supplied) as shown in Figure 8. Use #8 x 1" screws only.
Post
(optional)
Conduit/
PVC pipe
(customer supplied)
Holding base, run cables through cord seal holes.Punch out power cable knock outs as shown.
Note: Only remove knock outs for number of cables used.
Figure 4
Run cables through optional riser mounting kit and post.
Figure 5 Figure 6
Figure 7 Figure 8
Post Pump power cord,
alarm oat cable,
and pump oat cable
Riser mounting kit
(optional)
Pump power, alarm
power, and optional
auxiliary alarm cable
PSP
cord
receptacle
Pump
switch
cable
Pump
cable
Alarm
oat cable
Installation Instructions
Connect alarm power, pump power and alarm
oat switch as shown.
Incoming
pump
power
Incoming
alarm power
Alarm
oat
switch
Plug pump switch piggy-back plug into PSP cord
receptacle. If using optional ETM, plug this into back
of pump switch piggy-back plug. Plug pump in last.
Pump
plug
ETM
(optional)
Pump
switch
plug
PSP
cord
receptacle
Use electrical duct seal to ll around incoming power cords. Ensure
pocket is lled completely and the gaps lled around each cable.
Duct
seal
If ETM is used, snap into location as shown. Arrange cords as
shown. Receptacle is inserted into pocket. Push excess cord back
through cord seal. Install PVC dowels into unused holes of cord seal.
ETM (optional)
snaps into base
PSP receptacle
ts into pocket
Fill
unused
holes
in cord
seal
with
PVC
dowels
Firmly tighten cord seal nut so that cables do not
move and cord seal is held in place.
Cord
seal
nut
Install cover on base and screw into place.
Figure 9 Figure 10
Figure 11
Figure 13
Figure 12
Figure 14
WARNING: Failure to do so will allow sewer gases to enter
control panel causing corrosion and failure of electrical components.
WARNING: Failure to have the plugs in order described
as shown will effect proper operation of system.
L1
N
G
SJE-RHOMBUS® warrants to the original consumer that
this product shall be free of manufacturing defects for ve
years after the date of consumer purchase. During that time
period and subject to the conditions set forth below, SJE-
RHOMBUS® will repair or replace, for the original consumer,
any component which proves to be defective due to defective
materials or workmanship of SJE-RHOMBUS®.
ELECTRICAL WIRING AND SERVICING OF THIS
PRODUCT MUST BE PERFORMED BY A LICENSED
ELECTRICIAN.
THIS WARRANTY DOES NOT APPLY: (A) to damage
due to lightning or conditions beyond the control of SJE-
RHOMBUS®; (B) to defects or malfunctions resulting from
failure to properly install, operate or maintain the unit in
accordance with printed instructions provided; (C) to failures
resulting from abuse, misuse, accident, or negligence; (D) to
units which are not installed in accordance with applicable
local codes, ordinances, or accepted trade practices, and (E)
to units repaired and/or modied without prior authorization
from SJE-RHOMBUS®.
Some states do not allow limitations on how long an implied
warranty lasts, so the above limitation may not apply to
you. Some states do not allow the exclusion or limitation of
incidental or consequential damages, so the above limitation
or exclusion may not apply to you. This warranty gives you
specic legal rights, and you may also have other rights
which vary from state to state.
TO OBTAIN WARRANTY SERVICE: The consumer
shall assume all responsibility and expense for removal,
reinstallation, and freight. Any item to be repaired or replaced
under this warranty must be returned to SJE-RHOMBUS®,
or such place as designated by SJE-RHOMBUS®.
ANY IMPLIED WARRANTIES OF MERCHANTABILITY
OR FITNESS ARE LIMITED TO THE DURATION OF THIS
WRITTEN WARRANTY. SJE-RHOMBUS® SHALL NOT,
IN ANY MANNER, BE LIABLE FOR ANY INCIDENTAL
OR CONSEQUENTIAL DAMAGES AS A RESULT OF
A BREACH OF THIS WRITTEN WARRANTY OR ANY
IMPLIED WARRANTY.
SJE-Rhombus® Five-Year Limited Warranty
Turn on power and test alarm by pressing the
test silence switch. Horn will sound and alarm
light will illuminate.
Push to test
Perform nal testing on system by lifting pump
and alarm oat. When pump oat is lifted, the pump
will turn on. When alarm oat is lifted, the alarm
horn will sound and alarm light will illuminate.
Alarm
oat
Pump
oat
Installation Instructions
Figure 15
Figure 16
Power On
Indicator
NOTICE!
Products returned must be cleaned, sanitized, or decontaminated as necessary prior to shipment to ensure that employees
will not be exposed to health hazards in handling said material. All applicable laws and regulations shall apply.