Q Global Solutions QBUN-D-RF0612 BUN-D RF control module User Manual

Q Global Solutions (Xiamen) Electronics Corp. BUN-D RF control module Users Manual

Users Manual

BUN-D-RF User Manual
1Principle of system working
1.1 System connection
1
BUN-D RF control module
Digital Sensor extension cable
Digital Sensor
A1
A2
A3A4
B1B2B3B4
RED RED
BLACK BLACK
RED
GREEN
BLACK
Momentory switch Dome Buzzer power line
Latching relay Dome Buzzer (RF)
A1
A2
A3
Control module power line
2System function
power onthe system starts its self-diagnosis.
a. No SENSORthree beeps.
b. one SENSORtwo beeps.
c. two SENSORconnect to CLCR or LR ,one beep
Three beeps for other conditions.
Switch 1 OFFReverse system
Switch 1 ON Front system
Switch 2 OFFReverse systemthe maximum detection
distance is 6ft
Front systemthe maximum detection distance is 3ft.
Switch 2 ON Reverse sysytemThe maximum detection distance is
3ft.
Front system. the maximum detection distance is 2ft.
2.1 Self-diagnosis
two-Sensor system (SENSOR1SENSOR2
2.2 Front system/Reverse system shift
2.3 Corner SENSOR maximum detection distection shift
Obstacle position to its nearest sensor buzzer warning
7ft-4ft(middle SENSOR)
6ft-4ft(corner SENSOR)
4ft-2ft
within 2ft
intemittent beeps
Rapid beeps
Solid beep
2.4 Detection distance
3ft-2ft itermittent beeps
2ft-1ft
within 1ftsolid beep
Rapid beeps
buzzer warning
Obstacle position to its nearest sensor
2.4.1
2.4.2
To assure there is no false warning because of the fixity, the system should learn
the enviroment. Learning methodafter inatalling the sensor and control module
remove all obstacles in front or back of the vehicle. Power on, the system will warn
if there is fixity. Then, power off. Redo "on-off" for four times.( "off" time < 3
seconds), if "off" is > 5 seconds, the learning process stops. No time limit for "on"
time.) Wherein, the system enter learnig status, BUZZER beeps for 2 seconds, the
system stores the fixity into its memory.(the fixity distance< 1m). There will be no
false warning because of the fixity.
Power on, LED of Momentary switch lights up , the system starts to work for 5
minutes, then shut off automatically.LED turns off.
In operation time, press Momentary switchthe system shuts off at once. LED of
Momentary switch turns off
When the system is in off satuspress Momentary switchthe system restart and
work for five minutes.
When LED flashes, it shows that sensor has some problems.
Press the adjust switch, Buzzer beeps shortly, the volume from high to low, press
again, the volume from low to high. The volume is stored everytmie the switch is
pressed. The last volume remains until power on again.
2.5 Buzzer volume adjust
2.6 Fixity learning
2.7 Switch control function
3System components
3.1 Control module
Basic Specification
7. detection range
4. Operating temperature
5. store temperature
6. output frequency
3. Consume current
2. Operating voltage
1. Rating voltage
Specification
Item
DC12V
MAX40mA/12V
DC9.6V--16V
-30°C----+80°C
40KHz ? à 2KHz
-40°C---+85°C
0~2ft~4ft~7ft
8. Emiting frequency 433.92MHZ±75KHZ
3.2 Sensor and Sensor cable
Vertical 50°±10°
Plane 100°±20°
5Detecting angle
7ft
4Maximum detection distance
40KHz ± 2KHz
3input frequency
Item
6Detecting method
Specification
2Store temperature
1Operating temperature-30°C----+80°C
-40°C---+85°C
Ultrasonic 40KHz
Basic Specification
3.3 Lathing relay rf dome buzzer and momentary switch
-40°C---+85°C
high85±5 dB/10cm/12v
-30°C----+80°C
DC 9.6V--16V
MAX40mA/12V
12V
ParameterItem
Basic Specification
low75±5 dB/10cm/12v
1600Hz
2operating voltage
range
3Consume current
4temperature
5store temperature
7Volume frequency
6volume
1Rating voltage
4 Changes or modifications not expressly approved by the party