Q Global Solutions QBUN-D-RF0612 BUN-D RF control module User Manual
Q Global Solutions (Xiamen) Electronics Corp. BUN-D RF control module Users Manual
Users Manual
BUN-D-RF User Manual
1、Principle of system working
1.1 System connection
1
BUN-D RF control module
Digital Sensor extension cable
Digital Sensor
A1
A2
A3A4
B1B2B3B4
RED RED
BLACK BLACK
RED
GREEN
BLACK
Momentory switch Dome Buzzer power line
Latching relay Dome Buzzer (RF)
A1
A2
A3
Control module power line
2、System function
power on,the system starts its self-diagnosis.
a. No SENSOR:three beeps.
b. one SENSOR:two beeps.
c. two SENSOR:connect to CL、CR or L、R ,one beep;
Three beeps for other conditions.
Switch 1 OFF:Reverse system
Switch 1 ON: Front system
Switch 2 OFF:Reverse system,the maximum detection
distance is 6ft;
Front system,the maximum detection distance is 3ft.
Switch 2 ON: Reverse sysytem,The maximum detection distance is
3ft.
Front system. the maximum detection distance is 2ft.
2.1 Self-diagnosis
two-Sensor system (SENSOR1、SENSOR2)
2.2 Front system/Reverse system shift
2.3 Corner SENSOR maximum detection distection shift
Obstacle position to its nearest sensor buzzer warning
7ft-4ft(middle SENSOR)
6ft-4ft(corner SENSOR)
4ft-2ft
within 2ft
intemittent beeps
Rapid beeps
Solid beep
2.4 Detection distance
3ft-2ft itermittent beeps
2ft-1ft
within 1ftsolid beep
Rapid beeps
buzzer warning
Obstacle position to its nearest sensor
2.4.1
2.4.2
To assure there is no false warning because of the fixity, the system should learn
the enviroment. Learning method:after inatalling the sensor and control module,
remove all obstacles in front or back of the vehicle. Power on, the system will warn
if there is fixity. Then, power off. Redo "on-off" for four times.( "off" time < 3
seconds), if "off" is > 5 seconds, the learning process stops. No time limit for "on"
time.) Wherein, the system enter learnig status, BUZZER beeps for 2 seconds, the
system stores the fixity into its memory.(the fixity distance< 1m). There will be no
false warning because of the fixity.
Power on, LED of Momentary switch lights up , the system starts to work for 5
minutes, then shut off automatically.LED turns off.
In operation time, press Momentary switch,the system shuts off at once. LED of
Momentary switch turns off;
When the system is in off satus,press Momentary switch,the system restart and
work for five minutes.
When LED flashes, it shows that sensor has some problems.
Press the adjust switch, Buzzer beeps shortly, the volume from high to low, press
again, the volume from low to high. The volume is stored everytmie the switch is
pressed. The last volume remains until power on again.
2.5 Buzzer volume adjust
2.6 Fixity learning
2.7 Switch control function
3、System components
3.1 Control module
Basic Specification
7. detection range
4. Operating temperature
5. store temperature
6. output frequency
3. Consume current
2. Operating voltage
1. Rating voltage
Specification
Item
DC12V
MAX40mA/12V
DC9.6V--16V
-30°C----+80°C
40KHz ? à 2KHz
-40°C---+85°C
0~2ft~4ft~7ft
8. Emiting frequency 433.92MHZ±75KHZ
3.2 Sensor and Sensor cable
Vertical 50°±10°
Plane 100°±20°
5、Detecting angle
7ft
4、Maximum detection distance
40KHz ± 2KHz
3、input frequency
Item
6、Detecting method
Specification
2、Store temperature
1、Operating temperature-30°C----+80°C
-40°C---+85°C
Ultrasonic 40KHz
Basic Specification
3.3 Lathing relay rf dome buzzer and momentary switch
-40°C---+85°C
high:85±5 dB/10cm/12v
-30°C----+80°C
DC 9.6V--16V
MAX40mA/12V
12V
ParameterItem
Basic Specification
low:75±5 dB/10cm/12v
1600Hz
2、operating voltage
range
3、Consume current
4、temperature
5、store temperature
7、Volume frequency
6、volume
1、Rating voltage
4 、Changes or modifications not expressly approved by the party
responsible for compliance could void the user's authority to operate the
equipment.